Loading...
HomeMy WebLinkAbout222.20 1/4 3 NOTES: SIDE VIEW FRONT VIEW ISOMETRIC VIEW SECTION C SEE NOTE 3 1 SECTION A 1.D = INSIDE DIAMETER OF CULVERT PIPE, OR PIPE ARCH SPAN WIDTH, 36" MAXIMUM. 2.THE DISTANCE BETWEEN THE SAFETY BARS, AND BETWEEN THE TOP BAR AND THE CULVERT CROWN, SHALL BE EQUAL SPACES OF NO MORE THAN 24". THE DISTANCE MAY VARY 35/64" (±1") BETWEEN BARS TO FACILITATE PLACEMENT. 3.SLOPE SHALL MATCH SIDE SLOPE; 6H:1V PREFERRED, NOT STEEPER THAN 4H:1V. 8" D/4 SEE NOTE 2 SEE NOTE 2 SEE NOTE 2 24" 6" 8" CULVERT INVERT CULVERT CROWN FINISHED GROUND FIELD CUT PIPE BEVEL 10" (TYP.) 1 1/2" (TYP.) 3 1/2" (TYP.) 4" (TYP.) 1" MAX.1" MAX. 3/4" MAX. (TYP.) D-2", SEE NOTE 1 8" INSTALL RESIN BONDED ANCHOR (TYP.) 5 3/4"x3/4" DIA. THREADED ROD, 4" EMBEDMENT WITH HEX HEAD NUT (TYP.) 10" (TYP.) 1 1/2" (TYP.) 3 1/2" (TYP.) 4" (TYP.) 1" MAX.1" MAX. 3/4" MAX. (TYP.) D-2", SEE NOTE 1 8" INSTALL RESIN BONDED ANCHOR (TYP.) 5 3/4"x3/4" DIA. THREADED ROD, 4" EMBEDMENT WITH HEX HEAD NUT (TYP.) SECTION B 3 1/2" VARIES 7/8" DIA. HOLE 3/8" x 4" x 10" STEEL PLATE 3" x 3" x 5/16" STRUCTURAL TUBING (TYP.) D/4 D SEE NOTE 1 D/4 HEADWALL, SEE STD. PLAN 222.00 FOR DETAILS SAFETY BAR (TYP.) RESIN BONDED ANCHOR (TYP.) 3 1/2" x 3 1/2" BLOCKOUT (TYP.), FIELD CUT CULVERT TO MATCH BLOCKOUT IN HEADWALL CULVERT PIPE OR PIPE ARCHABC CTYPE 2 SAFETY BARS FOR CULVERT OR PIPE ARCH (ON CROSS ROADS) STD. PLAN - 222.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT