Loading...
HomeMy WebLinkAbout225.2012" 12" YARD DRAIN OR CATCH BASIN WITH SOLID LID 2' MIN. SECTION A PLAN ELEVATION HOUSE HOUSE 5' MIN.10' MIN.SEE NOTE 2 ROOF DOWNSPOUT WITH OVERFLOW WYE AND SPLASH BLOCK 6" DIA. MIN. PVC, SDR 35 PER ASTM D3034 6" MIN. FINE MESH SCREEN, SS304 10x10 OR SIMILAR 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 NON-WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 COMPACTED BACKFILL 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 6" MIN. 6" MIN. 12" MIN.APERFORATED PIPE TO BE LEVEL 3/4" TO 1-1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD SPECIFICATION SECTION 9-03.12(5) 12" MIN. ABOVE SEASONAL HIGH GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER FLEXIBLE GASKETED CAP PER ASTM D5926 NOTES: 1.15' MINIMUM SETBACK FROM INFILTRATION TRENCH TO BUILDINGS WITH CRAWL SPACES, BASEMENTS, OR ELEVATIONS BELOW THE OVERFLOW POINT. 2.REQUIRED TRENCH LENGTH VARIES DEPENDING ON SOIL TYPE, UP TO 100' MAX. WHEN LOCATED IN COARSE SANDS OR COBBLES, INFILTRATION TRENCHES MUST BE AT LEAST 20' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. WHEN LOCATED IN MEDIUM SANDS, INFILTRATION TRENCHES MUST BE AT LEAST 30' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. 3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 6" MIN. CLEANOUT PER STD. PLAN 226.00 24" MIN. SINGLE FAMILY ROOF DOWNSPOUT INFILTRATION TRENCH STD. PLAN - 225.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT