HomeMy WebLinkAbout234.0012'/15' MAINTENANCE ACCESS ROADNOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.SEE STANDARD PLAN 234.10 FOR TYPICAL DETENTION POND CROSS SECTIONS. 3.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STANDARD PLAN 234.50. 4.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 5.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY. 6.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 5.1.1.1 OF THE RENTON SWDM. 7.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STANDARD PLAN 234.40. 8.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. POND DESIGN WATER SURFACE 15% MAX.FLOWTRACT LINES AS REQUIRED POND INLET 5' SETBACK MIN. 6" SEDIMENT STORAGEFLOW ACCESS RAMP INTO POND COMPACTED EMBANKMENT LEVEL BOTTOM FLOWFLOWEMERGENCY OVERFLOW SPILLWAY ROCK LINING CONTROL STRUCTURE ALTERNATE EMERGENCY OUTFLOW STRUCTURE FOR PONDS NOT REQUIRED TO PROVIDE A SPILLWAY TOE OF SLOPE QUARRY SPALL PAD 3H:1V MAX. 3H:1V MAX. 3H:1V MAX. TYPICAL DETENTION POND STD. PLAN - 234.00C234.10PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)A234.10 B 234.10 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT