HomeMy WebLinkAbout237.00d ISOMETRIC SECTION A PLAN VIEW ELBOW RESTRICTOR DETAIL 1.USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2.OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. 3.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4.FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB-DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5.IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6.PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3'-0" VERTICAL SPACING). 7.LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8.LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10.IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. NOTES: 2" MIN. 6" MIN. 6" MAX. REMOVABLE WATERTIGHT COUPLING OR FLANGE PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED, SEE NOTE 3 DESIGN WATER SURFACE 16" MAX. 12" MIN. UNDER PAVEMENT 6" MIN. D 1.5 x D MIN.2' MIN. 2' MIN. 2' MIN. 12" 12" (TYP.) FRAME & SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 VERTICAL BAR GRATE FOR SECONDARY INLET HANDHOLDS, STEPS, OR LADDER SHEAR GATE WITH CONTROL ROD FOR CLEANOUT/DRAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER) PER STD. PLAN 237.30 INLET PIPEOUTLET PIPE, SEE NOTES 1 & 5 INVERT AND ELEVATION PER PLANS WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 2' MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS 2' MIN, ANGLE AS NECESSARY, SEE NOTE 7 ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WITH WATER ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 PIPE SUPPORTS, SEE NOTE 6 A ELEVATION PER PLANS SEE NOTE 9 (TYP.) 12" SECTION OF PIPE ATTACHED BY GASKETED BAND TO ALLOW REMOVAL FLOW CONTROL STRUCTURE - RESTRICTOR TEE STD. PLAN - 237.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT