Loading...
HomeMy WebLinkAbout242.00ALTERNATIVE DESIGN CATCH BASIN RECOMMENDED FOR HIGHER FLOW SITUATIONS (GENERALLY FOR INFLOW VELOCITIES OF 5 FPS OR GREATER FOR 100 YEAR STORM). *SAND FILTER MAY USE OTHER SPREADING OPTIONS. EXAMPLE OF ANCHORED PLATE USED WITH A SAND FILTER* (MAY ALSO BE USED WITH OTHER WATER QUALITY FACILITIES). PLAN SECTION A SAND BED NOTES: 1.FLOW SPREADER PLATES MAY BE MADE OF EITHER METAL, FIBERGLASS REINFORCED PLASTIC, RECYCLED PLASTIC, OR OTHER DURABLE MATERIAL. WOOD IS NOT ALLOWED. 2.ANCHOR POST SHALL BE 4-INCH SQUARE CONCRETE, TUBULAR STAINLESS STEEL, OR OTHER MATERIAL RESISTANT TO DECAY. WOOD IS NOT ALLOWED. 3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. INLET PIPE V-NOTCHED OR LEVEL PLATE SPREADER EXTEND INTO SLOPE TO PROTECT FROM THE 100-YEAR FLOW OR THE HIGHEST FLOW ENTERING WATER QUALITY FACILITY RIPRAP AS SHOWN ON PLANS (TYP.) POND SIDE SLOPES (TYP.) SAND LAYER GRAVEL LAYER EXISTING GRADE 2" MIN. 8" MIN. 2' MIN.2' MIN. EMBEDDED INTO EXISTING GROUND INLET PIPE2" MIN, EDGE OF SAND ANCHOR POSTS SPACED 6' O.C. OR AT EACH END IF WIDTH < 6'A2" MIN. THICK LEVEL SPREADER PLATE BOLTED TO ANCHOR POST RIPRAP AS SHOWN ON PLANS (TYP.) FLOW SPREADER - OPTION A ANCHORED PLATE STD. PLAN - 242.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT