Loading...
HomeMy WebLinkAbout249.10SCALE: CROSS-SECTION A 249.00NTS XXEMERGENCY OVERFLOW WS OVERFLOW WS WQ DESIGN WS INLET EMERGENCY OVERFLOW WS OVERFLOW WS WQ DESIGN WS NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 3.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 4.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY. 5.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 6.4.1.2 OF THE RENTON SWDM. 6.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STANDARD PLAN 234.40. 7.WETPONDS WITH WETPOOL VOLUMES LESS THAN OR EQUAL TO 4,000 CUBIC FEET MAY BE SINGLE-CELLED (I.E. NO BAFFLE OR BERM IS REQUIRED). 8.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 9.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. SLOPE VEGETATION PER DETENTION FACILITY REQUIREMENTS EMERGENT VEGETATION REQUIRED FOR WETPOOL DEPTHS 3' OR LESS KEYED BERM IF TOP OF BERM IS SUBMERGED 1' BELOW WQ DESIGN WS, BERM SIDE SLOPES MAY BE 2H:1V, OTHERWISE SIDE SLOPES MUST BE 3H:1V INLET EROSION CONTROL/SLOPE PROTECTION PER DETENTION FACILITY REQUIREMENTS 2' MIN. SEDIMENT STORAGE DEPTH, 12" MIN. FIRST CELL DEPTH 4' MIN. TO 8' MAX. WETPOOL FLOW LENGTH = 3 MIN. x WIDTH WETPOOL DEPTH 8' MAX. RECIRCULATION RECOMMENDED FOR DEPTH > 6' SEE STD. PLAN 234.40 FOR FENCE REQUIREMENTS ACCESS ROAD CAPACITY OF OUTLET SYSTEM SIZED TO PASS PEAK FLOW FOR CONVEYANCE REQUIREMENTS EXTERIOR BERMS DESIGNED PER DAM SAFETY REQUIREMENTS IF APPLICABLE MANHOLE OR TYPE 2 CATCH BASIN VALVE (MAY BE LOCATED INSIDE MH OR OUTSIDE WITH APPROVED OPERATIONAL ACCESS) GRAVITY DRAIN (IF GRADE ALLOWS) 8" MIN. DIAMETER INVERT 6" MIN. BELOW TOP OF INTERNAL BERM. LOWER PLACEMENT IS DESIRABLE 12" MIN 18" MIN. SCALE: CROSS-SECTION B 249.00NTS 6" SEDIMENT STORAGE COMPACT TO 95% OF MAXIMUM DRY DENSITY OUTLET PIPE INVERT AT WETPOOL WS ELEVATION SEE NOTE 8 (TYP.) TOP OF BERM OR BAFFLE TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) INLET SUBMERGED 12" MIN. TYPICAL WETPOND SECTIONS STD. PLAN - 249.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) 3 1 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT