Loading...
HomeMy WebLinkAbout252.10SCALE: CROSS-SECTION A 252.00NTS XXEMERGENCY OVERFLOW WS DETENTION OVERFLOW WS DETENTION DESIGN WS EMERGENCY OVERFLOW WS DETENTION OVERFLOW WS DETENTION DESIGN WS WQ DESIGN WS WQ DESIGN WS NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 3.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 4.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY OR ZONE 1 OF THE APA. 5.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 6.4.1.2 OF THE RENTON SWDM. 6.ALL FACILITIES SHALL BE FENCED IN ACCORDANCE WITH STD. PLAN 234.40. 7.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STD. PLAN 234.40. 8.COMBINED DETENTION AND WETPONDS WITH WETPOOL VOLUMES LESS THAN OR EQUAL TO 4,000 CUBIC FEET MAY BE SINGLE-CELLED (I.E. NO BAFFLE OR BERM IS REQUIRED). 9.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. GRAVITY DRAIN (IF GRADE ALLOWS) 8" MIN. DIAMETER 3 1 3 1 ACCESS ROAD SLOPE VEGETATION PER DETENTION FACILITY REQUIREMENTS EMERGENT VEGETATION REQUIRED FOR WETPOOL DEPTHS 3' OR LESS. TOP OF BERM OR BAFFLE TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) INLET EROSION CONTROL/SLOPE PROTECTION PER DETENTION FACILITY REQUIREMENTS INLET SUBMERGED 12" MIN. WETPOOL FLOW LENGTH = 3 x WIDTH MIN. 2' MIN. FIRST CELL DEPTH 4' MIN. TO 8' MAX. SEDIMENT STORAGE DEPTH, 12" MIN. KEYED BERM WETPOOL DEPTH 8' MAX. RECIRCULATION RECOMMENDED FOR DEPTH > 6' DETENTION PER DETENTION FACILITY REQUIREMENTS OUTLET PIPE INVERT OUT AT WETPOOL WS ELEVATION ACCESS ROAD CAPACITY OF OUTLET SYSTEM PER DETENTION FACILITY REQUIREMENTS EXTERIOR BERMS DESIGNED PER DAM SAFETY REQUIREMENTS IF APPLICABLE OUTLET FLOW CONTROL STRUCTURE PER STD. PLANS 237.00-237.20 VALVE INVERT 6" MIN. BELOW TOP OF INTERNAL BERM. LOWER PLACEMENT IS DESIRABLE 12" 18" MIN. SCALE: CROSS-SECTION B 252.00NTS SEE STD. PLAN 234.40 FOR FENCE REQUIREMENTS 6" SEDIMENT STORAGE SEE NOTE 9 (TYP.) COMPACT TO 95% OF MAXIMUM DRY DENSITY IF TOP OF BERM IS SUBMERGED 1' BELOW WQ DESIGN WS, BERM SIDE SLOPES MAY BE 2H:1V, OTHERWISE SIDE SLOPES MUST BE 3H:1V SEE NOTE 9 (TYP.) COMBINED DETENTION AND WETPOND SECTIONS STD. PLAN - 252.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT