HomeMy WebLinkAbout252.10SCALE:
CROSS-SECTION A
252.00NTS
XXEMERGENCY OVERFLOW WS
DETENTION OVERFLOW WS
DETENTION DESIGN WS
EMERGENCY OVERFLOW WS
DETENTION OVERFLOW WS
DETENTION DESIGN WS
WQ DESIGN WS
WQ DESIGN WS
NOTES:
1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN
CRITERIA.
2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50.
3.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL.
4.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY OR ZONE 1 OF THE APA.
5.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE
CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED
IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 6.4.1.2 OF THE RENTON SWDM.
6.ALL FACILITIES SHALL BE FENCED IN ACCORDANCE WITH STD. PLAN 234.40.
7.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STD. PLAN 234.40.
8.COMBINED DETENTION AND WETPONDS WITH WETPOOL VOLUMES LESS THAN OR EQUAL TO 4,000 CUBIC FEET MAY BE SINGLE-CELLED (I.E. NO BAFFLE OR BERM IS
REQUIRED).
9.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO
AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE.
10.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
GRAVITY DRAIN
(IF GRADE ALLOWS)
8" MIN. DIAMETER
3
1
3
1
ACCESS ROAD
SLOPE VEGETATION PER DETENTION
FACILITY REQUIREMENTS
EMERGENT VEGETATION
REQUIRED FOR WETPOOL
DEPTHS 3' OR LESS.
TOP OF BERM OR BAFFLE TO BE LEVEL
AND AT OR 1' BELOW WATER QUALITY
(WQ) DESIGN WATER SURFACE (WS)
INLET EROSION CONTROL/SLOPE
PROTECTION PER DETENTION
FACILITY REQUIREMENTS
INLET SUBMERGED 12" MIN.
WETPOOL FLOW LENGTH = 3 x WIDTH MIN.
2' MIN.
FIRST CELL
DEPTH 4' MIN.
TO 8' MAX.
SEDIMENT STORAGE
DEPTH, 12" MIN.
KEYED BERM
WETPOOL DEPTH 8' MAX.
RECIRCULATION
RECOMMENDED
FOR DEPTH > 6'
DETENTION PER
DETENTION FACILITY
REQUIREMENTS
OUTLET PIPE INVERT OUT AT
WETPOOL WS ELEVATION
ACCESS ROAD
CAPACITY OF OUTLET SYSTEM
PER DETENTION FACILITY
REQUIREMENTS
EXTERIOR BERMS DESIGNED PER
DAM SAFETY REQUIREMENTS
IF APPLICABLE
OUTLET FLOW CONTROL
STRUCTURE PER STD.
PLANS 237.00-237.20
VALVE
INVERT 6" MIN. BELOW TOP OF
INTERNAL BERM. LOWER
PLACEMENT IS DESIRABLE
12"
18" MIN.
SCALE:
CROSS-SECTION B
252.00NTS
SEE STD. PLAN 234.40 FOR
FENCE REQUIREMENTS
6" SEDIMENT STORAGE
SEE NOTE 9 (TYP.)
COMPACT TO 95% OF MAXIMUM
DRY DENSITY
IF TOP OF BERM IS SUBMERGED 1' BELOW WQ
DESIGN WS, BERM SIDE SLOPES MAY BE 2H:1V,
OTHERWISE SIDE SLOPES MUST BE 3H:1V
SEE NOTE 9 (TYP.)
COMBINED DETENTION AND
WETPOND SECTIONS
STD. PLAN - 252.10
PUBLIC WORKS
DEPARTMENT
APPROVED:
DATEGregg Zimmerman
Public Works Administrator
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878