HomeMy WebLinkAboutzSurfaceWaterSetPRECAST BASE SECTION SEE NOTE 1 NOTES: 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4.THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 34" 24" 30 " 20 " 5" 5" 1", 2", 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP*, STD. SPEC. 9-05.20 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1)15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2)15" * CORRUGATED POLYETHYLENE STORM SEWER PIPE 26", S E E N O T E 6 22 " , SE E N O T E 6 3"4"44"21" MIN.4" MI N. ( T Y P.) #3 BAR EACH SIDE #3 BAR EACH WAY #3 BAR EACH CORNER #3 BAR EACH CORNER 18" MIN. #3 BAR HOOP ALTERNATIVE PRECAST BASE SECTION CATCH BASIN TYPE 1 STD. PLAN - 200.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT REDUCING SECTION 36 " 20 " 40" 24" 6" 8" 8"12"4"32", SEE N O T E 6 28 " , SE E N O T E 6 4" MI N. ( T Y P.)44"2"PRECAST BASE SECTION SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION NOTES: 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 26". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'. 4.THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 34" 24" 30 " 20 " 5" 5" 1", 2", 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 #3 BAR EACH CORNER 18" MIN. #3 BAR HOOP PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 18" ALL METAL PIPE 21" CPSSP*, STD. SPEC. 9-05.20 18" SOLID WALL PVC, STD. SPEC. 9-05.12(1)21" PROFILE WALL PVC, STD. SPEC. 9-05.12(2)21" * CORRUGATED POLYETHYLENE STORM SEWER PIPE TWO #3 BAR HOOPS #3 BAR EACH SIDE #3 BAR EACH WAY #3 BAR EACH CORNER CATCH BASIN TYPE 1L STD. PLAN - 200.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 34" 24" 30 " 20 " 5" 5" NOTES:4"4" M I N . SE E N O T E 6 22 " , 4" MI N. 26", SEE N O T E 6 PRECAST BASE SECTION SE E N O T E 6 4" M I N . 4" MI N. 26", SEE N O T E 6 4"22 " ,32" MIN.56"SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION32" MIN.56"1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 18". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'. 4.THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 #3 BAR EACH SIDE #3 BAR EACH CORNER #3 BAR EACH WAY #3 BAR HOOP #3 BAR HOOP #3 BAR EACH CORNER, 18" (MIN.) 1", 2", 4", 6", 12", OR 24" CATCH BASIN TYPE 1P (FOR PARKING LOT) STD. PLAN - 200.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 4"25"PRECAST BASE SECTION NOTES: 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 18". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5'. 4.THE FRAME AND GRATE SHALL BE INSTALLED WITH THE FLANGE DOWN. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6.THE STRUCTURE OPENING DIMENSIONS SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 4" MI N. ( T Y P.) 26", SEE N O T E 6 22 " , SE E N O T E 6 SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION #3 BAR EACH SIDE TOP AND BOTTOM #3 BAR EACH CORNER ONE #3 BAR ACROSS BOTTOM #3 BAR EACH CORNER 18" (MIN.) #3 BAR HOOP PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP* , STD. SPEC. 9-05.20 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1)15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2)15" * CORRUGATED POLYETHYLENE STORM SEWER PIPE 34" 24" 30 " 20 " 5" 5" 1", 2", 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 CONCRETE INLET STD. PLAN - 200.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 2' 11-1/2" 2' 2"4-3/4"4-3/4" 2' 7"1' 10" 4-1/2" 4-1/2" DRA I N 3' 4" 3' 3' 6-1/4" 1' 11-1/2" 2' 9-1/2"2' 5" 6" 8" 3' 8" 5-1/2" 6" 5' 5-3/4" ONE #4 BAR HOOP #4s EACH SIDE OF OPENING CONVERSION RISER Ø 2' 6" 8" CONVERSION RISER ADJUSTMENT RINGS CONVERSION RISER STD. PLAN - 200.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DEPTH: 3.52' TO IE OUT DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2.THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3.THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4.KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5.ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 FLAT SLAB TOP SEE NOTE 6, TYP. REINFORCING STEEL, (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) INTEGRAL BASE PRECAST WITH RISER STEPS OR LADDER 4" MIN. 16" MAX.28" MAX. 48", 54", 60", 72", 84", 96", 120" OR 144" 12" (TYP.) 24" MIN.12" MAX. 1" MIN. 2.5" MAX. 12" 6" 15' MAX. FOR MAINTENANCE SEPARATE BASE PRECAST "O" RING 12" 6" CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48"4"6"36"8" 54"4.5"8"42"8" 60"5"8"48"8" 72"6"8"60"12" 84"8"12"72"12" 96"8"12"84"12" 120"10"12"96"12" 144"12"12"108"12" PIPE ALLOWANCES CATCH BASIN DIAMETER PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER CONCRETE ALL METAL CPSSP 1 SOLID WALL PVC 2 PROFILE WALL PVC 3 48"24"30"24"30"30" 54"30"36"30"36"36" 60"36"42"36"42"42" 72"42"54"42"48"48" 84"54"60"54"48"48" 96"60"72"60"48"48" 120"66"84"60"48"48" 144"78"96"60"48"48" 1 CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 2 STD. SPEC. 9-05.12(1) 3 STD. SPEC. 9-05.12(2) CATCH BASIN TYPE 2 STD. PLAN - 201.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT FRAME AND VANED GRATE ADJUSTMENT SECTION NOTES: 1.THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3. 2.SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3.A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4.ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR 12 BOND. 5.BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR. 6.MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3. 7.PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 9.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 10.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. BASE SECTION SEE NOTE 4 CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION CATCH BASIN INSTALLATION STD. PLAN - 202.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT ISOMETRIC VIEW SECTION A SEE NOTE 1 DETAIL SECTION A TOP VIEW FRAME DETAIL 1.THE INLET REQUIRES THE PRECAST CATCH BASIN TO BE ROTATED 90 DEGREES SO THAT THE NARROW SIDE IS PARALLEL TO THE CURB. WHEN CALCULATING OFFSETS FROM THE CURB TO CENTERLINE OF THE PRECAST CATCH BASIN, PLEASE NOTE THAT THE CENTERLINE OF THE GRATE IS NOT THE CENTERLINE OF THE PRECAST CATCH BASIN. 2.THE DIMENSIONS OF THE FRAME AND HOOD MAY VARY SLIGHTLY AMONG DIFFERENT MANUFACTURERS. HOOD UNITS SHALL MOUNT OUTSIDE OF THE FRAME. THE HOOD MAY INCLUDE CASTING LUGS. THE TOP OF THE HOOD MAY BE CAST WITH A PATTERN. SAFETY BARS ARE NOT ALLOWED ON THE HOOD. 3.ATTACH THE HOOD TO THE FRAME WITH TWO 3/4" × 2" HEX HEAD BOLTS, NUTS, AND OVERSIZE WASHERS. THE WASHERS SHALL HAVE DIAMETERS ADEQUATE TO ASSURE FULL BEARING ACROSS THE SLOTS. 4.FOR BOLT-DOWN GRATES, PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE SLOTS. TAP EACH HOLE TO ACCEPT A 5/8" × - 11 NC × 2" ALLEN HEAD CAP SCREW. LOCATION OF BOLT-DOWN HOLES VARIES AMONG DIFFERENT MANUFACTURERS. SEE BOLT- DOWN DETAIL. 5.ONLY DUCTILE IRON VANED GRATES SHALL BE USED. SEE STANDARD PLANS 204.20 AND 204.30. 6.THIS PLAN IS INTENDED TO SHOW THE INSTALLATION DETAILS OF A MANUFACTURED PRODUCT. IT IS NOT THE INTENT OF THIS PLAN TO SHOW THE SPECIFIC DETAILS NECESSARY TO FABRICATE THE CASTINGS SHOWN ON THIS DRAWING. NOTES: 1/2" MIN. ~ 5 1/2" R1" 1" MIN. OPENING HEIGHT 4" MIN. FRAME TOP OF GRATE SEE NOTE 3 HOOD LEVEL 1 6 1" MIN. (TYP.) 29" MIN. 20 1/4" 1 1/2" MIN. (TYP.) 24 1/4"29" MIN. SEE NOTE 4 (TYP.) SEE NOTE 2 (TYP.) CATCH BASIN CL GRATE CL ~ 3" ~ 7" ~ 34" (WIDE SIDE) CATCH BASIN TYPE 1 ~ 40" (WIDE SIDE) CATCH BASIN TYPE 1L CURB OR CURB AND GUTTER MATCH TOP OF HOOD TO TOP OF CURB (TYP.) HOOD DO NOT INSTALL SAFETY BAR / DEBRIS GUARD 20" x 24" VANED GRATE FRAME SEE DETAIL BELOWA HOLE OR SLOT FOR ATTACHING HOOD OPEN CURB FACE FRAME AND GRATE INSTALLATION STD. PLAN - 203.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.THIS FRAME IS DESIGNED TO ACCOMMODATE 20" × 24" GRATES OR COVERS, SEE STANDARD PLANS 204.10, 204.20, AND 204.30. 2.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 3.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. GRATE FRAME SEE NOTE 2 RECESSED ALLEN HEAD CAP SCREW 5/8" - 11 NC x 2" SECTION A DETAIL TOP ISOMETRIC VIEW BOLT-DOWN HOLE (TYP.) ~ 5/8", 11 NC, SEE DETAIL AND NOTE 2 29 1/4" 25 1/4" SECTION BOLT-DOWN DETAIL 24 1/4" SEE DETAIL 3/4" 4 1/2" 1 5/8" 2 1/2" 1 5/8" 1 1/4" 3/4" 7/8" 1/8"ARECTANGULAR FRAME STD. PLAN - 204.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT NOTES: BOLT-DOWN SLOT DETAIL SEE NOTE 1 SECTION A TOP SECTION B SECTION C 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. 3.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4.FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. 24" 1 1/2" 3" R26", SEE NOTE 2 BOLT-DOWN SLOT, SEE DETAIL AND NOTE 12 1/2" DIA. HOLE 1 5/8" MAX. 4 3/4"1 1/2" 3" R39", SEE NOTE 2 1 1/2" 1/2" DIA. HANDLE 3/4" DIA. HOLE 5/8" 3/4" 4" 3 1/2" 5" 1/2" 3/4" 1 1/4" 5/8"A CB20" ISOMETRIC PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) RECTANGULAR SOLID METAL COVER STD. PLAN - 204.10 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: ISOMETRIC SECTION B TOPFOUNDRY NAMEDIFLOW SECTION A 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3.FOR FRAME DETAILS, SEE STANDARD PLAN 204.00.FLOWFLOWBOLT-DOWN SLOT DETAIL SEE NOTE 1 1/2" 3/4" 1 1/4" 5/8" BOLT-DOWN SLOT, SEE DETAIL AND NOTE 1 20" 5" 5" 5" 3" 1" 3" 5" 5" 5" DIRECTION OF FLOW 24" 7 OR 8 EQUAL SPACES 1 5/8" MAX. A BOUTFALL TO STREAM DUMP NO POLLUTANTS 3/8" RECESSED LETTERING RECTANGULAR VANED GRATE STD. PLAN - 204.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT ISOMETRIC NOTES: SECTION B TOPFOUNDRY NAMEDIFLOW SECTION A 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3.USE ONLY IN SAGS ON VERTICAL CURVES. 4.FOR FRAME DETAILS, SEE STANDARD PLAN 204.00.FLOWFLOWBOLT-DOWN SLOT DETAIL SEE NOTE 1 1/2" 3/4" 1 1/4" 5/8" BOLT-DOWN SLOT, SEE DETAIL AND NOTE 1 20" 5" 5" 5" 3" 1" 3" 5" 5" 5" 24" 1 5/8" MAX. 4 EQUAL SPACES 4 EQUAL SPACES A BOUTFALL TO STREAM DUMP NO POLLUTANTS 3/8" RECESSED LETTERING RECTANGULAR BI-DIRECTIONAL VANED GRATE STD. PLAN - 204.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT COVER SECTION VIEW ASTM A48 CL35B00371780MO/DA/YR X3717C1PTEON BOLTING DETAIL GASKET GROOVE DETAIL FRAME SECTION VIEW COVER BOTTOM VIEW PLAN VIEW DRAINIFCOMADEINUSA EJIW DUMPNO P O L L U T A N T S -DRAINS T O S T REAMNOTES: 1.ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL. 2.THIS COVER SHALL ONLY BE USED FOR STRUCTURES WITHIN PRIVATE DEVELOPMENTS OUTSIDE OF PUBLIC RIGHT-OF-WAY. 1/2" LETTERING BOLT HOLES - 3 PLACES EQUALLY SPACED 120° APART ON 23 1/16" DIA. B.C. 1 1/4" LETTERING (1) 1" DIA. PICKHOLE 25" DIA. 3/4" 1" 2 1/2" 8 3/4" (TYP.) (3) BLT SOC. (ALLEN HEAD) 5/8"-11 x 1.5 SS RUBBER WASHER 5/8" 25 1/4" DIA. 26 1/2" DIA. 23 3/8" DIA. CL OPEN 27 5/16" DIA. 34 1/8" DIA. 1 1/16" 6" 1/8" 1/4"1 1/16" R1/8" 1/4" DIA. NEOPRENE GASKET SKID GROOVE PATTERN DETAIL ≈ 1/2"≈ 1/4" ≈ 3/16" SKID GROOVE PATTERN STORM ROUND FRAME AND COVER (PRIVATE) STD. PLAN - 204.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT COVER SECTION VIEW ASTM A48 CL35B00371780MO/DA/YR X3717C1PTEON BOLTING DETAIL GASKET GROOVE DETAIL FRAME SECTION VIEW COVER BOTTOM VIEW PLAN VIEW DRAINIFCOMADEINUSA EJIW DUMPNO P O L L U T A N T S -DRAINS T O S T REAMR E N T O N NOTES: 1.ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL. 1/2" LETTERING BOLT HOLES - 3 PLACES EQUALLY SPACED 120° APART ON 23 1/16" DIA. B.C. 1 1/4" LETTERING (1) 1" DIA. PICKHOLE 25" DIA. 3/4" 1" 2 1/2" 8 3/4" (TYP.) (3) BLT SOC. (ALLEN HEAD) 5/8"-11 x 1.5 SS RUBBER WASHER 5/8" 25 1/4" DIA. 26 1/2" DIA. 23 3/8" DIA. CL OPEN 27 5/16" DIA. 34 1/8" DIA. 1 1/16" 6"1/8" 1/4"1 1/16" R1/8" 1/4" DIA. NEOPRENE GASKET STORM ROUND FRAME AND COVER (PUBLIC) STD. PLAN - 204.50 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 5" ECCENTRIC CONE SECTION 72" FLAT SLAB TOP RECTANGULAR ADJUSTMENT SECTION CIRCULAR ADJUSTMENT SECTION PREFABRICATED LADDER STEP 84" or 96" FLAT SLAB TOP NOTES: 1.AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED FOR ADJUSTMENT SECTIONS. 48", 54", or 60" FLAT SLAB TOP 20"x24", 24" DIA., 48" DIA., OR 54" DIA. HOLE #6 BARS @ 7" SPACING 12" 2" (TYP.) 1" MIN. 2 1/2" MAX. 12" (TYP.) 12" 9" 6" 48" MAX. 24" MIN. #5 BARS @ 6" SPACING 20"x24", 24" DIA., 48" DIA., OR 54" DIA. HOLE 8" 2" (TYP.) 1" MIN. 2 1/2" MAX. TYPICAL ORIENTATION FOR ACCESS AND STEPS 6" 9 1/2" MAX. 12" MIN. 48" MIN. 24" MIN. 18" MIN. 42" MAX. #4 BARS @ 6" SPACING 20"x24" OR 24" DIA. HOLE 8" 2" (TYP.) 1" MIN. 2 1/2" MAX. 34" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 34" 24" 30 " 20 " 5" 5" 1", 2", 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 1", 2", 4", 6", 12", OR 24" MISCELLANEOUS DETAILS FOR DRAINAGE STRUCTURES STD. PLAN - 204.60 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLAN SECTION A SECTION B NOTES: TOP 1/4 1/4 (TYP.) SIDE END 10 1 1.THE TOP OF THE INLET SHALL BE PLACED AT GROUND LEVEL TO PRESENT AN UNOBSTRUCTED DITCH OR MEDIAN SECTION. 2.BEVEL OR ROUND EXPOSED CONCRETE EDGES 1/2". 3.PIPES MAY ENTER THROUGH THE KNOCKOUTS AT ANY REASONABLE ANGLE PROVIDED THE OUTSIDE OF THE PIPE CAN BE CONTAINED WITHIN THE KNOCKOUT PROVIDED. 4.THE GRADE LINE OF THE LOWEST INLET PIPE SHALL ENTER THE STRUCTURE AT AN ELEVATION EQUAL TO OR HIGHER THAN THE GRADE LINE OF THE OUTLET PIPE. 5.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 6.THE STEEL ANGLES SHALL BE SET SO THAT EACH BEARING BAR OF THE GRATE SHALL HAVE FULL SEATING ON BOTH ENDS. THE FINISHED TOP OF CONCRETE SHALL BE EVEN WITH THE GRATE SURFACE. 7.THE AMOUNT, TYPE, AND GRADE OF REINFORCING STEEL IS THE RESPONSIBILITY OF THE MANUFACTURER. 8.THE INSIDE WALL TAPER FOR FORM REMOVAL SHALL NOT RESULT IN ANY WALL SECTION THINNER THAN 6" EXCEPT IN PIPE KNOCKOUT AREAS. 9.PRECAST INLETS SHALL BE MARKED WITH THE MANUFACTURER'S IDENTIFICATION ON THE INSIDE OF THE STRUCTURE IN A READILY ACCESSIBLE LOCATION. END (ANCHOR STUD OPTION) 1/4 SECTION ON DITCH LINE DIKE INSTALLATION FOR PREFERRED SLOPE SEE CONTRACT FOR BACKSLOPE DETAILS 24" MIN. 12" MIN. TYPE 3 GRATE SHOWN DITCH LINE DITCH 84" 30"42" GRATE SUPPORT (TYP.), SEE DETAIL ~ 42" 6" MIN. 2" MIN. KNOCKOUT Ø34" 39"6" MIN. 48" 12" 4" 6" MIN. 3" 36" 18" 12" 4" x 3" x 1/2" x 35 1/4" STEEL ANGLE 4" 4" 1 1/2" GRATE SUPPORT DETAIL (FOUR SUPPORTS REQUIRED) 4" x 3" x 3/8" STEEL PLATE, TACK WELD TO ANGLE 5 1/2" x 1" x 1/4" STEEL ANGLE ISOMETRIC (SHOWN WITH TYPE 1 GRATE) 1/2" DIA. x 4" STEEL STUD, PLACE ALONG SUPPORT AS SHOWN FOR ANGLES A BDROP INLET TYPE 1 STD. PLAN - 205.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: PLAN SECTION A 1.THE TOP OF THE INLET SHALL BE PLACED AT GROUND LEVEL TO PRESENT AN UNOBSTRUCTED DITCH OR MEDIAN SECTION. 2.BEVEL OR ROUND EXPOSED CONCRETE EDGES 1/2". 3.PIPES MAY ENTER THROUGH THE KNOCKOUTS AT ANY REASONABLE ANGLE PROVIDED THE OUTSIDE OF THE PIPE CAN BE CONTAINED WITHIN THE KNOCKOUT PROVIDED. 4.THE GRADE LINE OF THE LOWEST INLET PIPE SHALL ENTER THE STRUCTURE AT AN ELEVATION EQUAL TO OR HIGHER THAN THE GRADE LINE OF THE OUTLET PIPE. 5.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2) 6.THE STEEL ANGLES SHALL BE SET SO THAT EACH BEARING BAR OF THE GRATE SHALL HAVE FULL SEATING ON BOTH ENDS. THE FINISHED TOP OF CONCRETE SHALL BE EVEN WITH THE GRATE SURFACE. 7.THE AMOUNT, TYPE, AND GRADE OF REINFORCING STEEL IS THE RESPONSIBILITY OF THE MANUFACTURER. 8.THE INSIDE WALL TAPER FOR FORM REMOVAL SHALL NOT RESULT IN ANY WALL SECTION THINNER THAN 6" EXCEPT IN PIPE KNOCKOUT AREAS. 9.PRECAST INLETS SHALL BE MARKED WITH THE MANUFACTURER'S IDENTIFICATION ON THE INSIDE OF THE STRUCTURE IN A READILY ACCESSIBLE LOCATION. SECTION B TOP 1/4 1/4 (TYP.) SIDE END 1/4 GRATE SUPPORT (TYP.), SEE DETAIL 34" DIA. KNOCKOUT 30"6" MIN. 48" 12" 4" 6" MIN. 3" 36" 18" 12" 4" x 3" x 1/2" x 35 1/4" STEEL ANGLE 4" 4" 1 1/2" GRATE SUPPORT DETAIL (FOUR SUPPORTS REQUIRED) 4" x 3" x 3/8" STEEL PLATE, TACK WELD TO ANGLE 5 1/2" x 1" x 1/4" STEEL ANGLE ISOMETRIC (SHOWN WITH TYPE 2 GRATE) 1/2" DIA. x 4" STEEL STUD, PLACE ALONG SUPPORT AS SHOWN FOR ANGLES 10'-0" 30"42" DITCH 2" MIN. A BEND (ANCHOR STUD OPTION) DROP INLET TYPE 2 STD. PLAN - 205.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT TYPE 1 TYPE 2 TYPE 3 SECTION C SECTION A1/4 SECTION B ISOMETRICS TYPE 2 TYPE 3 TYPE 1 (TYP.) 3 1/2" x 1/2" x 34 1/2" STEEL PLATE (TYP.)1 1/2" MAX. 34 1/4" 5 1/4"THREE SPACES 5 1/4" 34 1/2" OPTIONAL 1" MAX. VENT HOLES ON BOTTOM FOR GALVANIZING 3 1/2" x 1/2" x 34 1/2" STEEL PLATE (TYP.)1 1/2" MAX. 34 1/4" 3 1/2"FIVE SPACES 3 1/2" 34 1/2" OPTIONAL 1" MAX. VENT HOLES ON BOTTOM FOR GALVANIZING 3 1/2" x 31/2" x 5/16" x 33 1/4" STRUCTURAL TUBING (TYP.) 3 1/2" GRIND TOP AND BOTTOM FLUSH AFTER WELDING 1/4(TYP.) 3 1/2" x 31/2" x 5/16" x 33 1/4" STRUCTURAL TUBING (TYP.) 3 1/2" GRIND TOP AND BOTTOM FLUSH AFTER WELDING 34 1/4" 34 1/2" 2" (TYP.)2" (TYP.) 3 1/2" x 1/2" x 34 1/2" STEEL PLATE (TYP.) 1/4(TYP.) 3 1/2" 3 1/2" x 1/2" x 34 1/2" STEEL PLATE (TYP.) A B C GRATES FOR DROP INLET STD. PLAN - 205.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 9 1 3 1 CROSS SECTION 4' MIN. NOTES: OVERFLOW SPILLWAY 6' MIN. WIDTH 24" SETTLING DEPTH & 12" DEPTH OF 2"-4" ROCK, 12" DEPTH OF 3/4"-1 1/2" WASHED GRAVEL. 18" SEDIMENT STORAGE 12" DEPTH 2" - 4" ROCK 12" DEPTH 3/4" - 1 1/2" WASHED GRAVEL FILTER FABRIC FENCING 24" MIN. SETTLING DEPTH 1.5' MIN. SEDIMENT STORAGE 3.5' - 5'5' MAX. 12" OVERFLOW DEPTH OUTFLOW CHANNEL IF CONSTRUCTED BY EXCAVATION 1.MAY BE CONSTRUCTED BY EXCAVATION OR BY BUILDING A BERM SEDIMENT TRAP STD. PLAN - 211.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.TO ESTABLISH CLEARING LIMITS, STAKE AND WIRE FENCE MAY BE USED: 1.1.1.AT THE BOUNDARY OF CRITICAL AREAS, THEIR BUFFERS AND OTHER AREAS REQUIRED TO BE LEFT UNCLEARED. 1.1.2.AS NECESSARY TO CONTROL VEHICLE ACCESS TO AND ON THE SITE. 2.MAINTENANCE AND REQUIREMENTS 2.1.IF THE FENCE IS DAMAGED OR VISIBILITY REDUCED, IT SHALL BE REPAIRED OR REPLACED IMMEDIATELY AND VISIBILITY RESTORED. 2.2.DISTURBANCE OF A CRITICAL AREA, CRITICAL BUFFER AREA, NATIVE GROWTH RETENTION AREA, OR OTHER AREA REQUIRED TO BE LEFT UNDISTURBED SHALL BE REPORTED TO THE CITY OF RENTON FOR RESOLUTION. 2.3.THE CITY MAY REQUIRE MORE SUBSTANTIAL FENCING IF THE FENCE DOES NOT PREVENT ENCROACHMENT INTO THOSE AREAS THAT ARE NOT TO BE DISTURBED. NOTES SURVEY FLAGGINGBAILING WIRE DO NOT NAIL OR STAPLE WIRE TO TREES METAL FENCE POST (TYP.)3' MIN. 10' - 20' 12" MIN. STAKE AND WIRE FENCE STD. PLAN - 212.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 3 1 MAX. "TRACKING" WITH MACHINERY UP AND DOWN THE SLOPE PROVIDES GROOVES THAT WILL CATCH SEED, RAINFALL AND REDUCE RUNOFF. TRACKING 1.CONDITIONS OF USE 1.1.ALL SLOPES STEEPER THAN 3H:1V AND GREATER THAN 5 VERTICAL FEET REQUIRE SURFACE ROUGHENING TO A DEPTH OF 2 TO 4 INCHES PRIOR TO SEEDING. 1.2.AREAS THAT WILL NOT BE STABILIZED IMMEDIATELY MAY BE ROUGHENED TO REDUCE RUNOFF VELOCITY UNTIL SEEDING TAKES PLACE. 1.3.SLOPES WITH A STABLE ROCK FACE DO NOT REQUIRE ROUGHENING. 1.4.SLOPES WHERE MOWING IS PLANNED SHOULD NOT BE EXCESSIVELY ROUGHENED. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.DISTURBED AREAS THAT WILL NOT REQUIRE MOWING MAY BE STAIR-STEP GRADED, GROOVED, OR LEFT ROUGH AFTER FILLING. 2.2.STAIR STEP GRADING IS PARTICULARLY APPROPRIATE IN SOILS CONTAINING LARGE AMOUNTS OF SOFT ROCK. STAIR SHOULD BE WIDE ENOUGH TO WORK WITH STANDARD EARTH MOVING EQUIPMENT. STAIRS STEPS MUST BE ON CONTOURS OR GULLIES WILL FORM ON THE SLOPE. 2.3.AREAS THAT WILL BE MOWED, MAY HAVE SMALL FURROWS LEFT BY DISKING, HARROWING, RAKING, OR SEED-PLANTING MACHINERY OPERATED ON THE CONTOUR. 2.4.GRADED AREAS WITH SLOPES GREATER THAN 3H:1V BUT LESS THAN 2H:1V SHOULD BE ROUGHENED BEFORE SEEDING BY TRACKING. 2.5.TRACKING IS DONE BY OPERATING EQUIPMENT UP AND DOWN THE SLOPE TO LEAVE HORIZONTAL DEPRESSIONS IN THE SOIL. 3.MAINTENANCE STANDARDS 3.1.PERIODICALLY CHECK ROUGHENED, SEEDED, PLANTED AND MULCHED SLOPES FOR RILLS AND GULLIES, PARTICULARLY AFTER A SIGNIFICANT STORM EVENT. FILL THESE AREAS SLIGHTLY ABOVE THE ORIGINAL GRADE, THEN RE-SEED AND MULCH AS SOON AS POSSIBLE. NOTES: 50' 6" MIN. CONTOUR FURROWS GROOVES WILL CATCH SEED, FERTILIZER, MULCH, RAINFALL, AND DECREASE RUNOFF SURFACE ROUGHENING STD. PLAN - 213.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.FOR PERMANENT STABILIZATION OF SLOPES 2H:1V OR GREATER AND WITH MORE THAN 10 FEET OF VERTICAL RELIEF. 1.2.IN CONJUNCTION WITH SEED FOR FINAL STABILIZATION OF A SLOPE, NOT FOR TEMPORARY COVER. HOWEVER, THEY MAY BE USED FOR TEMPORARY APPLICATIONS AS LONG AS THE PRODUCT IS NOT DAMAGED BY REPEATED HANDLING. 1.3.THE APPLICATION OF APPROPRIATE NETTING OR BLANKET TO DRAINAGE DITCHES AND SWALES CAN PROTECT BARE SOIL FROM CHANNELIZED RUNOFF WHILE VEGETATION IS ESTABLISHED. NETS AND BLANKETS CAN ALSO CAPTURE A GREAT DEAL OF SEDIMENT DUE TO THEIR OPEN, POROUS STRUCTURE. SYNTHETIC NETS AND BLANKETS MAY BE USED TO PERMANENTLY STABILIZE CHANNELS AND MAY PROVIDE A COST-EFFECTIVE, ENVIRONMENTALLY PREFERABLE ALTERNATIVE TO RIPRAP. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.INSTALLATION IS CRITICAL TO THE EFFECTIVENESS OF THIS PRODUCT. IF GOOD GROUND CONTACT IS NOT ACHIEVED, RUNOFF CAN CONCENTRATE UNDER THE PRODUCT, RESULTING IN SIGNIFICANT EROSION. 2.2.JUTE MATTING MUST BE USED IN CONJUNCTION WITH MULCH. EXCELSIOR, WOVEN STRAW BLANKETS, AND COIR (COCONUT FIBER) BLANKETS MAY BE INSTALLED WITHOUT MULCH. OTHER TYPES OF PRODUCTS WILL BE EVALUATED INDIVIDUALLY. 2.3.PURELY SYNTHETIC BLANKETS ARE ALLOWED, BUT SHALL ONLY BE USED FOR LONG-TERM STABILIZATION OF WATERWAYS. THE ORGANIC BLANKETS ARE BETTER FOR SLOPE PROTECTION AND SHORT-TERM WATERWAY PROTECTION. 2.4.DO NOT STRETCH BLANKET/MATTINGS TIGHT - ALLOW THE ROLLS TO MOLD TO ANY IRREGULARITIES. 2.5.SLOPE SURFACE SHALL BE SMOOTH BEFORE PLACEMENT FOR PROPER SOIL CONTACT. 2.6.ANCHOR, STAPLE, AND INSTALL CHECK SLOTS AS PER MANUFACTURER'S RECOMMENDATION. 2.7.AVOID JOINING MATERIAL IN THE CENTER OF THE DITCH. 2.8.LIME, FERTILIZE, AND SEED BEFORE INSTALLATION. 3.MAINTENANCE STANDARDS 3.1.GOOD CONTACT WITH THE GROUND MUST BE MAINTAINED, AND THERE MUST NOT BE EROSION BENEATH THE NET OR BLANKET. 3.2.AREAS OF THE NET OR BLANKET THAT ARE DAMAGED OR NOT IN CLOSE CONTACT WITH THE GROUND SHALL BE REPAIRED AND STAPLED. 3.3.IF EROSION OCCURS DUE TO POORLY CONTROLLED DRAINAGE, THE PROBLEM SHALL BE FIXED AND THE ERODED AREA PROTECTED. NOTES: 4" MIN. OVERLAP 6" MIN. OVERLAP WATERWAY INSTALLATIONS OF NETS AND BLANKETS STD. PLAN - 213.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.FOR PERMANENT STABILIZATION OF SLOPES 2H:1V OR GREATER AND WITH MORE THAN 10 FEET OF VERTICAL RELIEF. 1.2.IN CONJUNCTION WITH SEED FOR FINAL STABILIZATION OF A SLOPE, NOT FOR TEMPORARY COVER. HOWEVER, THEY MAY BE USED FOR TEMPORARY APPLICATIONS AS LONG AS THE PRODUCT IS NOT DAMAGED BY REPEATED HANDLING. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.INSTALLATION IS CRITICAL TO THE EFFECTIVENESS OF THIS PRODUCT. IF GOOD GROUND CONTACT IS NOT ACHIEVED, RUNOFF CAN CONCENTRATE UNDER THE PRODUCT, RESULTING IN SIGNIFICANT EROSION. 2.2.JUTE MATTING MUST BE USED IN CONJUNCTION WITH MULCH. EXCELSIOR, WOVEN STRAW, BLANKETS, AND COIR (COCONUT FIBER) BLANKETS MAY BE INSTALLED WITHOUT MULCH. 2.3.PURELY SYNTHETIC BLANKETS ARE ALLOWED, BUT SHALL ONLY BE USED FOR LONG-TERM STABILIZATION OF WATERWAYS. THE ORGANIC BLANKETS ARE BETTER FOR SLOPE PROTECTION AND SHORT-TERM WATERWAY PROTECTION BECAUSE THEY RETAIN AND PROVIDE ORGANIC MATTER TO THE SOIL, SUBSTANTIALLY IMPROVING THE SPEED AND SUCCESS OF RE-VEGETATION. 2.4.DO NOT STRETCH BLANKETS/MATTINGS TIGHT - ALLOW THE ROLLS TO MOLD TO ANY IRREGULARITIES. 2.5.SLOPE SURFACE SHALL BE SMOOTH BEFORE PLACEMENT FOR PROPER SOIL CONTACT. 2.6.STAPLING PATTERN AS PER MANUFACTURER'S RECOMMENDATION. 2.7.IF THERE IS A BERM AT THE TOP OF SLOPE, ANCHOR UPSLOPE OF THE BERM. 2.8.FOR SLOPES LESS THAN 3H:1V, ROLLS MAY BE PLACED IN HORIZONTAL STRIPS. 2.9.LIME, FERTILIZE, AND SEED BEFORE INSTALLATION. PLANTING OF SHRUBS, TREES, ETC. SHOULD OCCUR AFTER INSTALLATION. 3.MAINTENANCE STANDARDS 3.1.GOOD CONTACT WITH THE GROUND MUST BE MAINTAINED, AND THERE MUST NOT BE EROSION BENEATH THE NET OR BLANKET. 3.2.AREAS OF THE NET OR BLANKET THAT ARE DAMAGED OR NOT IN CLOSE CONTACT WITH THE GROUND SHALL BE REPAIRED AND STAPLED. 3.3.IF EROSION OCCURS DUE TO POORLY CONTROLLED DRAINAGE, THE PROBLEM SHALL BE FIXED AND THE ERODED AREA PROTECTED. NOTES: 2" MIN. OVERLAP 6" MIN. OVERLAP ANCHOR IN 6" x 6" MIN. TRENCH AND STAPLE AT 12" INTERVALS BRING MATERIAL DOWN TO A LEVEL AREA, TURN THE END UNDER 4", AND STAPLE AT 12" INTERVALS STAPLE OVERLAPS 5' MAX. SPACING SLOPE INSTALLATIONS OF NETS AND BLANKETS STD. PLAN - 213.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.PLASTIC COVERING MAY BE USED ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS. 1.2.PLASTIC IS PARTICULARLY USEFUL FOR PROTECTING CUT AND FILL SLOPES AND STOCKPILES. 1.3.CLEAR PLASTIC SHEETING MAY BE USED OVER NEWLY-SEEDED AREAS TO CREATE A GREENHOUSE EFFECT AND ENCOURAGE GRASS GROWTH. CLEAR PLASTIC SHOULD NOT BE USED FOR THIS PURPOSE DURING THE SUMMER MONTHS. 1.4.THIS METHOD SHALL NOT BE USED UPSLOPE OF AREAS THAT MIGHT BE ADVERSELY IMPACTED BY RUNOFF. SUCH AREAS INCLUDE STEEP AND UNSTABLE SLOPES. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.PLASTIC SHEETING SHOULD HAVE A MINIMUM THICKNESS OF 0.06 MILLIMETERS. 2.2.IF EROSION AT THE TOE OF A SLOPE IS LIKELY, A GRAVEL BERM, RIPRAP, OR OTHER SUITABLE PROTECTION SHALL BE INSTALLED AT THE TOE OF THE SLOPE IN ORDER TO REDUCE THE VELOCITY OF RUNOFF. 2.3.TIRES, SAND BAGS, OR EQUIVALENT MAY BE USED TO WEIGHT PLASTIC. 2.4.SEAMS BETWEEN SHEETS MUST OVERLAP A MINIMUM OF 12 INCHES AND BE WEIGHTED OR TAPED. 3.MAINTENANCE STANDARDS 3.1.TORN SHEETS MUST BE REPLACED AND OPEN SEAMS REPAIRED. 3.2.IF THE PLASTIC BEGINS TO DETERIORATE DUE TO ULTRAVIOLET RADIATION, IT MUST BE COMPLETELY REMOVED AND REPLACED. 3.3.WHEN THE PLASTIC IS NO LONGER NEEDED, IT SHALL BE COMPLETELY REMOVED. NOTES: 10' MAX.. 10' MAX. TOE IN SHEETING IN 4" x 4" MIN. TRENCH PROVIDE ENERGY DISSIPATION AT TOE IF EROSION IS LIKELY SANDBAG (TYP.) PLASTIC COVERING STD. PLAN - 213.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT WOODEN STAKE LIVE STAKE ROLL SPACING DEPENDS ON SOIL TYPE AND SLOPE STEEPNESS STRAW ROLLS MUST BE PLACED ALONG SLOPE CONTOURS 4' 3'-30', SEE NOTE 2.3 SEDIMENT, ORGANIC MATTER, AND NATIVE SEEDS ARE CAPTURED BEHIND THE ROLLS ADJACENT ROLLS SHALL TIGHTLY ABUT 8"-10" DIA. 3"-5", SEE NOTE 2.2 NOTES: 1.CONDITIONS OF USE 1.1.INSTALL ON DISTURBED AREAS THAT REQUIRE IMMEDIATE EROSION PROTECTION. 1.2.USE ON SLOPES REQUIRING STABILIZATION UNTIL PERMANENT VEGETATION CAN BE ESTABLISHED. 1.3.CAN BE USED ALONG THE PERIMETER OF A PROJECT, AS A CHECK DAM IN UNLINED DITCHES AND AROUND TEMPORARY STOCKPILES. 1.4.WATTLES CAN BE STAKED TO THE GROUND USING WILLOW CUTTINGS FOR ADDED REVEGETATION. 1.5.RILLING CAN OCCUR BENEATH AND BETWEEN WATTLES IF NOT PROPERLY ENTRENCHED, ALLOWING WATER TO PASS BELOW AND BETWEEN WATTLES. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.IT IS CRITICAL THAT WATTLES ARE INSTALLED PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOUR. 2.2.NARROW TRENCHES SHOULD BE DUG ACROSS THE SLOPE, ON CONTOUR, TO A DEPTH OF 3 TO 5 INCHES ON CLAY SOILS AND SOILS WITH GRADUAL SLOPES. ON LOOSE SOILS, STEEP SLOPES, AND DURING HIGH RAINFALL EVENTS, THE TRENCHES SHOULD BE DUG TO A DEPTH OF 5 TO 7 INCHES, OR 1/2 TO 2/3 OF THE THICKNESS OF THE WATTLE. 2.3.START CONSTRUCTION OF TRENCHES AND INSTALLING WATTLES FROM THE BASE OF THE SLOPE AND WORK UPHILL. EXCAVATED MATERIAL SHOULD BE SPREAD EVENLY ALONG THE UPHILL SLOPE AND COMPACTED USING HAND TAMPING OR OTHER METHOD. CONSTRUCT TRENCHES AT CONTOUR INTERVALS OF 3 TO 30 FEET APART DEPENDING ON THE STEEPNESS OF THE SLOPE, SOIL TYPE, AND RAINFALL. THE STEEPER THE SLOPE THE CLOSER TOGETHER THE TRENCHES SHOULD BE CONSTRUCTED. VERTICAL DISTANCE BETWEEN WATTLES IS NOT TO EXCEED 10 FEET. 2.4.INSTALL THE WATTLES SNUGLY INTO THE TRENCHES AND ABUT TIGHTLY END TO END. DO NOT OVERLAP THE ENDS. 2.5.INSTALL STAKES AT EACH END OF THE WATTLE, AND AT 4 FOOT CENTERS ALONG THE ENTIRE LENGTH OF THE WATTLE. 2.6.IF REQUIRED, INSTALL PILOT HOLES FOR THE STAKES USING A STRAIGHT BAR TO DRIVE HOLES THROUGH THE WATTLE AND INTO THE SOIL. 2.7.AT A MINIMUM, WOODEN STAKES SHOULD BE APPROXIMATELY 3/4 X 3/4 X 24 INCHES. WILLOW CUTTINGS OR 3/8-INCH REBAR CAN ALSO BE USED FOR STAKES. 2.8.STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF THE WATTLE, LEAVING 2 TO 3 INCHES OF THE STAKE PROTRUDING ABOVE THE WATTLE. 3.MAINTENANCE STANDARDS 3.1.INSPECT WATTLES PRIOR TO FORECASTED RAIN, DAILY DURING EXTENDED RAIN EVENTS, AFTER RAIN EVENTS, WEEKLY DURING THE WET SEASON, AND AT TWO WEEK INTERVALS AT ALL OTHER TIMES OF THE YEAR. 3.2.REPAIR OR REPLACE SPLIT, TORN, RAVELING, OR SLUMPING WATTLES 3.3.REMOVE SEDIMENT ACCUMULATIONS WHEN EXCEEDING 1/2 THE HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND SURFACE. STRAW WATTLES STD. PLAN - 213.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2.SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. 2.2.STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3.WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V 2.4.IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5.FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3.MAINTENANCE STANDARDS 3.1.ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2.IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3.IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4.SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5.IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. NOTES: JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC 2' MIN. 12" MIN. 4"x4" MIN. TRENCH BACKFILL TRENCH WITH NATIVE SOIL OR 3/4" TO 1-1/2" WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) 6' MAX. POST SPACING MAY BE INCREASED TO 8' IF WIRE BACKING IS USED AOS (ASTM D4751)30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491)0.02 SEC-1 MINIMUM GRAB TENSILE STRENGTH (ASTM D4632)180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632)30% MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355)70% MIN. SILT FENCE STD. PLAN - 214.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT ATTACHMENT DETAILS: 1.GATHER FABRIC AT POSTS, IF NEEDED. 2.UTILIZE THREE TIES PER POST, ALL WITHIN TOP 8" OF FABRIC. 3.POSITION EACH TIE DIAGONALLY, PUNCTURING HOLES VERTICALLY A MINIMUM OF 1" APART. 4.HANG EACH TIE ON A POST NIPPLE AND TIGHTEN SECURELY. USE CABLE TIES (50 LBS) OR SOFT WIRE. TOP OF FABRIC BELT DIAGONAL ATTACHMENT DOUBLES STRENGTH FLOW STEEL SUPPORT POSTNOTES: 1.POST SPACING: 7' MAX. ON OPEN RUNS 4' MAX. ON POOLING AREAS. 2.POST DEPTH: AS MUCH BELOW GROUND AS FABRIC ABOVE GROUND. 3.PONDING HEIGHT 24" MAX. ATTACH FABRIC TO UPSTREAM SIDE OF POST. 4.DRIVE OVER EACH SIDE OF SILT FENCE 2 TO 4 TIMES WITH DEVICE EXERTING 60 P.S.I. OR GREATER. 5.NO MORE THAN 24" OF A 36" FABRIC ROLL IS ALLOWED ABOVE GROUND. 6.VIBRATORY PLOW IS NOT ACCEPTABLE BECAUSE OF HORIZONTAL COMPACTION. 100% COMPACTION EACH SIDE OPERATION SILT FENCE TOP 8" 200-300mm (8"-12") ROLL OF SILT FENCE PLOW FABRIC ABOVE GROUND SLICING BLADE (18mm (11/16") WIDTH) HORIZONTAL CHISEL POINT (76mm (3") WIDTH) SILT FENCE INSTALLATION BY SLICING STD. PLAN - 214.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLAN VIEW ELEVATION VIEW SECTION A NOTES: 6" SEWER PIPE WITH BUTTERFLY VALVES 8'x8' SUMP WITH 5' OF CATCH TO ACCOMMODATE CLEANING BY TRACKHOE 3" TRASH PUMP WITH FLOATS ON SUCTION HOSE 2" SCH 40 1 1/2" SCH 40 FOR SPRAYERS MIDPOINT SPRAY NOZZLES, IF NEEDED 2% SLOPE5H:1V5H:1V2% SLOPE 1H:1V1H:1V15' ATB APRON TO PROTECT GROUND FROM SPLASHING WATER ATB CONSTRUCTION ENTRANCE ASPHALT CURB ON THE LOW ROAD SIDE TO DIRECT WATER BACK TO POND 6" SLEEVE UNDER ROAD BALL VALVE (TYP.) CURB 6" SLEEVE 15'15'20'15'50' 5' 18' 12' 3' 1 1 LOCATE INVERT OF TOP PIPE 12" TO 14" ABOVE BOTTOM OF WHEEL WASH 8'x8' SUMP TO ACCOMMODATE CLEANING BY TRACKHOE DRAIN PIPE WITH BUTTERFLY VALVE WATER LEVEL, 12" TO 14" DEEPA6" ATB OVER CRUSHED BASE MATERIAL OR 8" ATB OVER A GOOD SUBGRADE 5% - 10%SLOPE1.CONDITIONS OF USE 1.1.WHEN A STABILIZED CONSTRUCTION ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, WHEEL WASHING IS GENERALLY AN EFFECTIVE EROSION AND SEDIMENT CONTROL METHOD AND BMP WHEN INSTALLED WITH CAREFUL ATTENTION TO TOPOGRAPHY. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.USE A LOW CLEARANCE TRUCK TO TEST THE WHEEL WASH BEFORE PAVING. EITHER A BELLY DUMP OR LOWBOY WILL WORK WELL TO TEST CLEARANCE. 2.2.MIDPOINT SPRAY NOZZLES ARE ONLY NEEDED IN VERY MUDDY CONDITIONS. 2.3.POLYACRYLAMIDE (PAM) ADDED TO WHEEL WASHWATER AT A RATE OF 0.25-0.5 POUNDS PER 1,000 GALLONS OF WATER INCREASES EFFECTIVENESS AND REDUCES CLEANUP TIME. IF PAM IS ALREADY BEING USED FOR DUST OR EROSION CONTROL AND IS BEING APPLIED BY A WATER TRUCK, THE SAME TRUCK MAY BE USED TO CHANGE THE WASHWATER. 3.MAINTENANCE STANDARDS 3.1.THE WHEEL WASH SHOULD START OUT EACH DAY WITH CLEAN, FRESH WATER. 3.2.THE WASHWATER SHOULD BE CHANGED A MINIMUM OF ONCE PER DAY. ON LARGE EARTHWORK JOBS WHERE MORE THAN 10 TO 20 TRUCKS PER HOUR ARE EXPECTED, THE WASHWATER WILL NEED TO BE CHANGED MORE OFTEN. 3.3.WHEEL WASH OR TIRE BATH WASHWATER SHALL BE DISCHARGED TO A SEPARATE ONSITE TREATMENT SYSTEM, SUCH AS A CLOSED-LOOP RECIRCULATION SYSTEM OR LAND APPLICATION, OR TO THE SANITARY SEWER SYSTEM WITH PROPER APPROVAL AND/OR PERMITS FROM KING COUNTY AND THE CITY OF RENTON. WHEEL WASH AND PAVED CONSTRUCTION ENTRANCE STD. PLAN - 215.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT EXIST I N G R O A D 1.CONDITION OF USE 1.1.CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. 1.2.FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTH/WIDTH TO PROVIDE VEHICLE ACCESS/PARKING, BASED ON LOT SIZE/CONFIGURATION. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: 2.2.DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3.HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.4.FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5.WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3.MAINTENANCE STANDARDS 3.1.QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2.IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3.ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4.ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5.IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. NOTES: CONSTRUCTION ENTRANCE NOTES: 1.DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. 2.IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS GEOTEXTILE 4"-8" QUARRY SPALLS 12" MIN. THICKNESS 15' MIN. PROVIDE FULL WIDTH OF INGRESS/EGRESS AREA 100' MIN. GRAB TENSILE STRENGTH (ASTM D4632)200 LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632)30% MAX. (WOVEN) CBR PUNCTURE STRENGTH (ASTM D6241)495 LBS. MIN. AOS (ASTM D4751)20-45 (U.S. STANDARD SIEVE SIZE) R = 25' MIN. STABILIZED CONSTRUCTION ENTRANCE STD. PLAN - 215.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 2H:1V MAX .3H:1V MAX.3H:1V MAX . 1.CONDITION OF USE 1.1.A SEDIMENT POND SHALL BE USED WHERE THE CONTRIBUTING DRAINAGE AREA IS 3 ACRES OR MORE. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.THE POND SHALL BE DIVIDED INTO TWO ROUGHLY EQUAL VOLUME CELLS BY A PERMEABLE DIVIDER THAT WILL REDUCE TURBULENCE WHILE ALLOWING MOVEMENT OF WATER BETWEEN CELLS. THE DIVIDER SHALL BE AT LEAST ONE HALF OF THE HEIGHT OF THE RISER. WIRE - BACKED, 2-TO 3 FOOT HIGH, EXTRA STRENGTH FILTER FABRIC SUPPORTED BY TREATED 4"X4"s MAY BE USED AS A DIVIDER. ALTERNATIVELY, STAKED STRAW BALES WRAPPED WITH FILTER FABRIC MAY BE USED. 2.2.IF THE POND IS MORE THAN 6 FEET DEEP, A DIFFERENT MECHANISM MUST BE PROPOSED. 2.3.TO AID IN DETERMINING SEDIMENT DEPTH, ONE-FOOT INTERVALS SHALL BE PROMINENTLY MARKED ON THE RISER. 3.MAINTENANCE STANDARDS 3.1.SEDIMENT SHALL BE REMOVED FROM THE POND WHEN IT REACHES 1 FOOT IN DEPTH. 3.2.ANY DAMAGES TO THE POND EMBANKMENTS OR SLOPES SHALL BE REPAIRED. NOTES: POND LENGTH (3 TO 6 TIMES THE MAX. POND WIDTH) SILT FENCE OR EQUIVALENT DIVIDER RISER PIPE INFLOW KEY DIVIDER INTO SLOPE TO PREVENT FLOW AROUND SIDES EMERGENCY OVERFLOW SPILLWAY DISCHARGE TO STABILIZED CONVEYANCE, OUTLET, OR LEVEL SPREADER 6' MIN.12" MIN. 12" CREST OF EMERGENCY SPILLWAY RISER PIPE (PRINCIPAL SPILLWAY), OPEN AT TOP WITH DEBRIS BARRIER, SEE STD. PLAN 234.20 DEWATERING DEVICE (SEE RISER DETAIL, STD. PLAN 216.10) DEWATERING ORIFICE CONCRETE BASE DISCHARGE TO STABILIZED CONVEYANCE, OUTLET, OR LEVEL SPREADER EMBANKMENT COMPACTED 95%. PERVIOUS MATERIALS SUCH AS GRAVEL OR CLEAN SAND SHALL NOT BE USED WIRE-BACKED SILT FENCE, STAKED HAY BALES WRAPPED WITH FILTER FABRIC, OR EQUIVALENT DIVIDER 3.5' MIN. SEDIMENT POND PLAN VIEW AND CROSS SECTIONS STD. PLAN - 216.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT POLYETHYLENE CAP PROVIDE ADEQUATE STRAPPING CORRUGATED METAL RISER TACK WELD WATERTIGHT COUPLING PERFORATED POLYETHYLENE DRAINAGE TUBING, DIAMETER 2" MIN. LARGER THAN DEWATERING ORIFICE. TUBING SHALL COMPLY WITH ASTM F667 AND AASHTO M294 CONCRETE BASE (ALTERNATIVELY, METAL STAKES AND WIRE MAY BE USED TO PREVENT FLOTATION) DEWATERING ORIFICE, SCH 40 STEEL STUB, MIN. DIAMETER AS PER CALCULATIONS IN SECTION D.2.1.5.2 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL 3.5' MIN. 6" MIN. 18" MIN. 2 x RISER DIA. MIN. 1.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. NOTES: RISER PIPE (PRINCIPAL SPILLWAY) OPEN AT TOP WITH DEBRIS BARRIER, SEE STD. PLAN 234.20 SEDIMENT POND RISER DETAIL STD. PLAN - 216.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT NOTES: SECTION VIEW ISOMETRIC VIEW DRAINAGE GRATE TRIM GRATE FRAME FILTERED WATER SEDIMENT AND DEBRIS OVERFLOW BYPASS BELOW INLET GRATE DEVICE DRAINAGE GRATE (RECTANGULAR GRATE SHOWN)RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) BELOW INLET GRATE DEVICE 1.PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2.INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3.THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4.SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5.THE BIGD SHALL HAVE A BUILT-IN HIGH-FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6.THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7.PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). 8.ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. 5" MAX. CATCH BASIN INSERT STD. PLAN - 216.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLAN VIEW NOTES: 1.PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2.INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3.THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4.USE BLOCK AND GRAVEL TYPE SEDIMENT BARRIER WHEN CURB INLET IS LOCATED IN GENTLY SLOPING SEGMENT, WHERE WATER CAN POND AND ALLOW SEDIMENT TO SEPARATE FROM RUNOFF. 5.BARRIER SHALL ALLOW FOR OVERFLOW FROM SEVERE STORM EVENT. 6.INSPECT BARRIERS AND REMOVE SEDIMENT AFTER EACH STORM EVENT. SEDIMENT AND GRAVEL MUST BE REMOVED FROM THE TRAVELED WAY IMMEDIATELY. 7.BLOCK AND GRAVEL CURB INLET PROTECTION MAY ONLY BE USED IN LANES NOT OPEN TO TRAFFIC. SECTION A CATCH BASIN OVERFLOW WATER CATCH BASIN COVERBACK OF SIDEWALK 2"x4" WOOD STUD CURB INLET CONCRETE BLOCKSWIRE SCREEN OR FILTER FABRIC 3/4" DRAIN GRAVEL WIRE SCREEN OR FILTER FABRIC 3/4" DRAIN GRAVEL POND HEIGHT 2"x4" WOOD STUD CATCH BASIN COVER CURB INLETA BLOCK AND GRAVEL CURB INLET PROTECTION STD. PLAN - 216.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT RUNOFF RUNOFF SPILLWAY NOTES: 1.PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2.INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3.THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4.PLACE CURB TYPE SEDIMENT BARRIERS ON GENTLY SLOPING STREET SEGMENTS, WHERE WATER CAN POND AND ALLOW SEDIMENT TO SEPARATE FROM RUNOFF. 5.SANDBAGS OF EITHER BURLAP OR WOVEN GEOTEXTILE FABRIC, SHALL BE FILLED WITH GRAVEL, LAYERED AND PACKED TIGHTLY. 6.LEAVE A ONE SANDBAG GAP IN THE TOP ROW TO PROVIDE A SPILLWAY FOR OVERFLOW. 7.INSPECT BARRIERS AND REMOVE SEDIMENT AFTER EACH STORM EVENT. SEDIMENT AND GRAVEL MUST BE REMOVED FROM THE TRAVELED WAY IMMEDIATELY. 8.CURB AND GUTTER BARRIER PROTECTION MAY ONLY BE USED IN LANES NOT OPEN TO TRAFFIC. BACK OF SIDEWALK CURB INLET CURB FACE GUTTER DRAIN GRATE SANDBAGS TO OVERLAP ONTO CURB GRAVEL FILLED SANDBAGS STACKED TIGHTLY CURB AND GUTTER BARRIER PROTECTION STD. PLAN - 216.50 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.REQUIRED AT: 1.1.1.THE TOP OF ALL SLOPES IN EXCESS OF 3H:1V AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF. 1.1.2.AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELOW. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.FOR SLOPES STEEPER THAN 2H:1V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED INTERCEPTOR DIKES MAY BE USED. THE DESIRED MEASURE MUST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY RUNOFF TO A SEDIMENT POND OR TRAP. 2.2.CONSTRUCTION TRAFFIC OVER TEMPORARY DIKES SHALL BE MINIMIZED. 3.MAINTENANCE STANDARDS 3.1.DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. 3.2.IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE DIKES SHALL BE INCREASED. NOTES: 2' MIN.18" MIN. DIKE SPACING DEPENDS ON SLOPE GRADIENT DIKE MATERIAL COMPACTED TO 90% MODIFIED PROCTOR 2 MAX. 1 2 MAX. 1 AVERAGE SLOPE SLOPE PERCENT FLOW PATH LENGTH 20H:1V (OR LESS)3-5%300 FEET (10 TO 20)H:1V 5-10%200 FEET (4 TO 10)H:1V 10-25%100 FEET (2 TO 4)H:1V 25-50%50 FEET INTERCEPTOR DIKE STD. PLAN - 217.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.REQUIRED AT: 1.1.1.THE TOP OF ALL SLOPES IN EXCESS OF 3H:1V AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF. 1.1.2.AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELOW. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.FOR SLOPES STEEPER THAN 2H:1V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED INTERCEPTOR SWALES MAY BE USED. THE DESIRED MEASURE MUST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY RUNOFF TO A SEDIMENT POND OR TRAP. 2.2.CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED. 3.MAINTENANCE STANDARDS 3.1.DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. 3.2.IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED. NOTES: 2 MAX. 1 AVERAGE SLOPE SLOPE PERCENT FLOW PATH LENGTH 20H:1V (OR LESS)3-5%300 FEET (10 TO 20)H:1V 5-10%200 FEET (4 TO 10)H:1V 10-25%100 FEET (2 TO 4)H:1V 25-50%50 FEET 2 MAX. 1 2' MIN. 12" MIN. SWALE SPACING DEPENDS ON SLOPE GRADIENT LEVEL BOTTOM INTERCEPTOR SWALE STD. PLAN - 217.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.PIPE SLOPE DRAINS SHOULD BE USED WHEN A TEMPORARY OR PERMANENT STORMWATER CONVEYANCE IS NEEDED TO MOVE WATER DOWN A STEEP SLOPE TO AVOID EROSION. 1.2.PIPE SLOPE DRAINS MAY BE CONNECTED TO NEW CATCH BASINS AND USED TEMPORARILY UNTIL ALL PERMANENT PIPING IS INSTALLED. 1.3.PIPE SLOPE DRAINS MAY BE USED ON ANY SLOPE WITH A GRADIENT OF 2H:1V OR GREATER AND WITH AT LEAST 10 FEET OF VERTICAL RELIEF. 1.4.PIPE SLOPE DRAINS MAY BE USED TO DRAIN WATER COLLECTED FROM AQUIFERS EXPOSED ON CUT SLOPES AND CONVEY IT TO THE BASE OF THE SLOPE. 1.5.PIPE SLOPE DRAINS MAY BE USED TO COLLECT CLEAN RUNOFF FROM PLASTIC SHEET COVER AND DIRECT AWAY FROM ANY EXPOSED SOILS. 1.6.PIPE SLOPE DRAINS MAY BE INSTALLED IN CONJUNCTION WITH SILT FENCE TO DRAIN COLLECTED WATER TO A CONTROLLED AREA. 1.7.PIPE SLOPE DRAINS MAY BE USED TO TEMPORARILY DIVERT SMALL SEASONAL STREAMS AWAY FROM CONSTRUCTION. 1.8.PIPE SLOPE DRAINS MAY BE CONNECTED TO EXISTING DOWNSPOUTS AND ROOF DRAINS USED TO DIVERT WATER AWAY FROM WORK AREAS DURING BUILDING RENOVATION, DEMOLITION, AND CONSTRUCTION PROJECTS. 1.9.PIPE SLOPE DRAINS MAY BE ROCK-LINED DITCHES OR OTHER PERMANENT, NON-EROSIVE CONVEYANCES USED TO CONVEY RUNOFF DOWN STEEP SLOPES THAT ARE NOT STEEP SLOPE HAZARDS. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.THE MAXIMUM DRAINAGE AREA ALLOWED FOR ANY SIZED PIPE IS 10 ACRES. FOR LARGER AREAS MORE THAN ONE PIPE SHALL BE USED OR A ROCK LINED CHANNEL SHALL BE INSTALLED. 2.2.THE SOIL AROUND AND UNDER THE PIPE AND ENTRANCE SECTION SHALL BE THOROUGHLY COMPACTED. 2.3.THE FLARED INLET SECTION SHALL BE SECURELY CONNECTED TO THE SLOPE DRAIN AND BE FUSED OR WELDED, OR HAVE FLANGE-BOLTED MECHANICAL JOINTS TO ENSURE A WATERTIGHT SEAL. 2.4.SLOPE DRAINS SHALL BE CONTINUOUSLY FUSED, WELDED OR FLANGE-BOLTED MECHANICAL JOINT PIPE SYSTEMS WITH PROPER ANCHORING TO THE SOIL. 2.5.WHERE THE SLOPE DRAINS CROSS STEEP SLOPE HAZARD AREAS OR THEIR ASSOCIATED BUFFERS, THE INSTALLATION SHALL BE ON THE GROUND SURFACE. ANY AREA DISTURBED DURING INSTALLATION AND MAINTENANCE MUST BE IMMEDIATELY STABILIZED. 2.6.RE-ESTABLISH COVER IMMEDIATELY ON AREAS DISTURBED BY THE INSTALLATION. 3.MAINTENANCE STANDARDS 3.1.THE INLET SHALL NOT BE UNDERCUT OR BYPASSED BY WATER. IF THERE ARE PROBLEMS, THE HEAD WALL SHALL BE APPROPRIATELY REINFORCED. 3.2.NO EROSION SHALL OCCUR AT THE OUTLET POINT. IF EROSION OCCURS ADDITIONAL PROTECTION SHALL BE ADDED. NOTES: DIKE MATERIAL COMPACTED 90% MODIFIED PROCTOR CORRUGATED METAL, CPE, OR EQUIVALENT PIPE DISCHARGE TO A STABILIZED WATERCOURSE, SEDIMENT RETENTION FACILITY, OR STABILIZED OUTLET 12" MIN. STANDARD FLARED END SECTION INLET AND ALL SECTIONS MUST BE SECURELY FASTENED TOGETHER WITH GASKETED WATERTIGHT FITTINGS INTERCEPTOR DIKE INTERCEPTOR DIKE PROVIDE RIPRAP PAD OR EQUIVALENT ENERGY DISSIPATION PIPE SLOPE DRAIN STD. PLAN - 217.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT A B 1.CONDITIONS OF USE 1.1.WHERE THERE IS CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM SEDIMENT PONDS OR TRAPS. 1.2.TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON-EROSIVE DISCHARGE POINT. 2.MAINTENANCE STANDARDS 2.1.ANY SEDIMENT DEPOSITION OF MORE THAN 6 INCHES SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY. 2.2.THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION HAS OCCURRED, AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET OR NET. NOTES: ROCK MUST COMPLETELY COVER THE BOTTOM AND SIDES OF THE DITCH 6" MIN. 24" MIN. L = THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION L 2"-4" ROCK 2 1 2 1 SECTION A SECTION B CHECK DAM (TYP.) PLANAB 18" MIN. FLOW DITCH BOTTOM OF DITCH 18" MIN. DITCH CHECK DAMS STD. PLAN - 217.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SPREADER MUST BE LEVEL 1.CONDITIONS OF USE 1.1.MAY BE USED WHERE RUNOFF FROM UNDISTURBED AREAS OR SEDIMENT RETENTION FACILITIES IS DISCHARGED. 1.2.APPLIES ONLY WHERE THE SPREADER CAN BE CONSTRUCTED ON UNDISTURBED SOIL AND THE AREA BELOW THE LEVEL SPREADER IS VEGETATED AND LOW GRADIENT. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.THE TOTAL SPREADER LENGTH SHALL BE AT LEAST THE SQUARE ROOT OF THE CATCHMENT AREA. 2.2.MAXIMUM LENGTH FOR AN INDIVIDUAL SPREADER IS 50 FEET. 2.3.MULTIPLE SPREADERS SHALL NOT BE PLACED UPHILL OR DOWNHILL FROM ONE ANOTHER. 2.4.THE AREA BELLOW THE SPREADER FOR A HORIZONTAL DISTANCE OF 100 FEET SHALL NOT EXCEED 20 PERCENT AND SHALL BE COMPLETELY VEGETATED WITH NO AREAS OF INSTABILITY OR EROSION. THE TOPOGRAPHY FOR A HORIZONTAL DISTANCE OF 50 FEET BELOW THE SPREADER SHALL BE UNIFORM SO THAT RUNOFF IS NOT FUNNELED INTO A SWALE OR CHANNEL IMMEDIATELY AFTER ITS RELEASE. 2.5.THE AREA BELOW THE LEVEL SPREADER SHALL BE SEEDED AND MULCHED. 3.MAINTENANCE STANDARDS 3.1.ANY DAMAGE TO THE SPREADER SHALL BE IMMEDIATELY REPAIRED. ENSURE FLOWS DO NOT BYPASS THE SPREADER AT THE ENDS OF THE SPREADER. 3.2.THE DOWNSLOPE AREA SHALL BE CHECKED FOR SIGNS OF EROSION AND VERIFY THAT THE SPREADER IS NOT FUNCTIONING AS A POINT DISCHARGE. 3.3.ANY ERODED AREAS SHALL BE IMMEDIATELY STABILIZED, AND THE CAUSE DETERMINED AND ELIMINATED IF POSSIBLE. NOTES: CEDAR OR PRESSURE TREATED 2"x10" DENSELY VEGETATED FOR A MIN. OF 100' AND A SLOPE OF LESS THAN 5H:1V 2 MAX. 1 12" MIN. 3' MIN. TREATED 2"X10" MAY BE ABUTTED END TO END FOR MAX. SPREADER LENGTH OF 50' 6" MIN.1" MIN. 6" MIN. 18" MIN. REBAR SUPPORTS (TYP.) 8' MIN. LEVEL SPREADER DETAIL AND CROSS SECTION STD. PLAN - 217.50 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 460' 470' 48 0 ' 4 9 0 ' 50 0 ' ELEV. 502' ELEV. 495' ELEV. 440' ELEV. 460' 1 2 " P I P E SWALELEGEND: PROPERTY LINE STREET CENTERLINE CONTOUR WETLAND STEEP SLOPE (40%+) OFFSITE DRAINAGE S.A.S.B. = SENSITIVE AREA SETBACK SF SF SF SF NE Q ST. NE P S T . TOP OF SLOPE TOE OF SLOPE SILT FENCE APPROX. AREA TO BE CLEARED. ALL EXPOSED SOILS WILL BE MULCHED WHEN NOT BEING WORKED. MARK CLEARING LIMIT WITH S.A.S.B. FENCE STABILIZED CONSTRUCTION ENTRANCE FLAG WETLAND BUFFER EDGE WITH S.A.S.B. TAPE APPLICANT: Malene McResident 600 NE Z Street Sometown, WA 98111 (206) 555-1212 PROJECT PARCEL NO. - 322708 PROJECT ADDRESS - 7519 NE Q Street (proposed) Sometown, WA 98111 SECTION/TOWNSHIP/RANGE: 32-27-08 TOTAL SITE ACREAGE: 1.69 TOTAL IMPERVIOUS AREA: 6950 SQ. FT. MAINTAIN ROCKED TRAFFIC AREAS AS NECESSARY. CSWPP/ESC CONTACT: Malene McResident (206) 555-1212 DISTURBED ACREAGE: APPROX. 0.9 APPROX. BUILDING FOOTPRINT CONCRETE WASHOUT AREA ROCKED PARKING/MATERIALS STORAGE; CONDUCT MAINTENANCE OFFSITE OR PROVIDE SPILL PROTECTION SAMPLE SMALL SITE EROSION CONTROL PLAN STD. PLAN - 218.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) N Scale in Feet 0 30 60 120 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT RIGID PIPE NOTES: 1.PIPE COMPACTION LIMITS SHOWN ON THIS PLAN ARE FOR PIPE CONSTRUCTION IN AN EMBANKMENT. FOR PIPE CONSTRUCTION IN A TRENCH, THE HORIZONTAL LIMITS OF THE PIPE COMPACTION ZONE SHALL BE THE WALLS OF THE TRENCH. 2.O.D. IS EQUAL TO THE OUTSIDE DIAMETER OF A PIPE OR THE OUTSIDE SPAN OF PIPE-ARCH. 3.SEE STANDARD WSDOT/APWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH. 4.PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6" LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 5.EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOT/APWA SPECIFICATIONS SECTION 9-03.17. GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)) OR MAINTENANCE ROCK (WSDOT 9-03.9(4)) CIRCULAR PIPE FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 5 SPAN 6" PIPE - ARCH 6" PIPE TYPE MINIMUM COVER (FT)PUBLIC?PRIVATE?ALLOWED IN ZONE 1 OF THE APA? CORRUGATED STEEL PIPE 2.0 YES YES YES SPIRAL RIB STEEL PIPE 2.0 YES YES YES PLAIN CONCRETE PIPE (PCP)2.0 NO YES NO REINFORCED CONCRETE PIPE (RCP) 1.0 YES YES NO DUCTILE IRON PIPE 1.0 YES YES YES FOUNDATION LEVEL RISE TRENCH WIDTH, SEE NOTE 3 CIRCULAR PIPE DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 12" TO 24"12" 30" TO 96"DIAMETER / 3 102" TO 180"48" PIPE-ARCH SPAN MINIMUM DISTANCE BETWEEN BARRELS 18" TO 36"12" 43" TO 142"SPAN / 3 148" TO 199"48" TRENCH WIDTH, SEE NOTE 3 6" O.D. 6" FOUNDATION LEVEL PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 4 FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 5 PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 4 PIPE ZONE BEDDING AND COMPACTION - RIGID PIPE STD. PLAN - 220.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT FLEXIBLE PIPE NOTES: 1.PROVIDE UNIFORM SUPPORT UNDER BARRELS. 2.HAND TAMP UNDER HAUNCHES. 3.DIRECTLY OVER PIPE, HAND TAMP ONLY. 4.SEE STANDARD WSDOT/APWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH. 5.PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6" LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 6.EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOT/APWA SPECIFICATIONS SECTION 9-03.17. SEE NOTE 4, LIMIT OF PIPE ZONE 6" O.D. 6" FOUNDATION LEVEL PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 5 FLEXIBLE PIPE PIPE TYPE MINIMUM COVER (FT)PUBLIC?PRIVATE?ALLOWED IN ZONE 1 OF THE APA? LINE CORRUGATED POLYETHYLENE PIPE (LCPE)2.0 YES YES YES CORRUGATED POLYETHYLENE PIPE (CPE) - TRIPLE WALL 2.0 YES YES YES POLYVINYL CHLORIDE PIPE (PVC)3.0 YES YES YES SOLID WALL HIGH DENSITY POLYETHYLENE PIPE (HDPE)2.0 YES YES YES POLYPROPYLENE PIPE (PP) - DUAL WALL 2.0 YES YES YES DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 12" TO 24"12" 30" TO 96"DIAMETER / 3 102" TO 180"48" GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)) OR MAINTENANCE ROCK (WSDOT 9-03.9(4)) FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 6 PIPE ZONE BEDDING AND COMPACTION - FLEXIBLE PIPE STD. PLAN - 220.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 12" MIN. 6" MIN. , SEE NOTE 4 EXISTING PAVEMENT SURFACE SURFACE RESTORATION AS SPECIFIED IN CONTRACT DOCUMENTS "CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03.9(3), "BANK RUN GRAVEL FOR TRENCH BACKFILL" PER WSDOT STD. SPEC 9-03.19, OR "GRAVEL BORROW" PER WSDOT STD. SPEC 9-03.14(1), COMPACTED TO 95% OF MAXIMUM DENSITY BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER PIPE ZONE BEDDING AND BACKFILL PER STD. PLANS 220.00 AND 220.10 PIPE NEAT LINE TRENCH UNPAVED AREAS PAVED AREAS SEE NOTE 1 NOTES: 1.SEE WSDOT/APWA STANDARD SPECIFICATIONS SECTION 2-09.4 FOR MEASUREMENT OF TRENCH WIDTH. 2.EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD DESCRIBED IN CHAPTER 295-155 PART N OF THE WAC. 3.MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER. 4.IN PAVED AREAS, IF PIPE HAS LESS THAN 3' OF COVER, USE "CRUSHED SURFACING TOP COURSE" FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE. 5.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. SEE STANDARD PLANS 110, 110.1, 110.2, AND 111 FOR PAVEMENT RESTORATION REQUIREMENTS "CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03.9(3), COMPACTED TO 95% OF MAXIMUM DENSITY TYPICAL TRENCH AND BACKFILL STD. PLAN - 220.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: METAL PIPE 4H:1V O R S T E E P E R 4H:1V O R S T E E P E R 4H:1V O R S T E E P E R CONCRETE PIPE THERMOPLASTIC PIPE 1.THE CULVERT ENDS SHALL BE BEVELED TO MATCH THE EMBANKMENT OR DITCH SLOPE AND SHALL NOT BE BEVELED FLATTER THAN 4H:1V. WHEN SLOPES ARE BETWEEN 4H:1V AND 6H:1V, SHAPE THE SLOPE IN THE VICINTIY OF THE CULVERT END TO ENSURE THAT NO PART OF THE CULVERT PROTRUDES MORE THAN 4" ABOVE THE GROUND LINE. 2.FIELD CUTTING OF CULVERT ENDS IS PERMITTED WHEN APPROVED BY THE ENGINEER. ALL FIELD-CUT METAL CULVERT PIPE SHALL BE TREATED WITH TREATMENT AS SHOWN IN WSDOT STD. SPECIFICATION 9-05.4(3). DRAWN BY: MARK SUJKA 4" MAX. END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE WSDOT STD. SPEC. 7-02.3(1)) 4" MAX. 4" MAX. END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE WSDOT STD. SPEC. 7-02.3(1)) END SECTION LENGTH SHALL BE AT LEAST SIX TIMES THE DIAMETER OF THE PIPE (SEE WSDOT STD. SPEC. 7-02.3(1)) BEVELED END SECTIONS STD. PLAN - 221.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT FOR 12" THRU 24" PIPEAND 17" x 13" THRU28" x 20" PIPE ARCH WITHANNULAR END CORRUGATIONSTYPE 1TYPE 3DESIGN ACONNECTION TO METAL PIPEFOR 42" THRU 84" PIPE AND49" x 33" THRU 83" x 57" PIPE ARCHWITH ANNULAR END CORRUGATIONS, AND ALLHELICAL END CORRUGATED PIPE AND PIPE ARCHDESIGN BDESIGN CPIPE & PIPE ARCH - PLANSECTION APIPE ARCH - ELEVATIONPIPE - ELEVATIONCONNECTION TO CONCRETEPIPE INLET END ONLYCONNECTION TO METAL ORCONCRETE PIPE OUTLET ONLY1.THE DIAMETER OF THE END SECTION OF DESIGN B SHALL MATCH THE INSIDE DIAMETER OF THECONCRETE PIPE.2.SKIRT SECTIONS SHALL BE MADE IN ONE PIECE FOR ROUND PIPE WITH A DIAMETER OF 12" TO 24"INCLUSIVE AND FOR PIPE ARCHES WITH A RISE OF 13" TO 20" INCLUSIVE. SKIRT SECTIONS FORLARGER SIZES OF PIPES MAY BE MULTIPLE PIECES IN CONFORMANCE WITH THE TABULATEDVALUES SHOWN.3.DESIGN A END SECTIONS FOR 42" THRU 84" DIAMETER AND 49" X 33" THRU 83" X 57" ARCH WITHANNULAR CORRUGATIONS AND ALL HELICALLY CORRUGATED PIPE ARCH INCLUDE ONE FOOT OFPIPE LENGTH AS A CONNECTOR SECTION. THE CONNECTOR SECTION SHALL BE ATTACHED TO THEEND SECTION BY WELDS, RIVETS OR BOLTS AND SHALL BE THE SAME THICKNESS AS THE ENDSECTION.4.DESIGN C MAY BE USED IN LIEU OF DESIGN A FOR ALL METAL PIPE SIZES EXCEPT AS NOTED.COUPLING BANDS MAY BE ANY ACCEPTABLE TYPE FOR THE PIPE SPECIFIED.5.MULTIPLE PANEL SKIRTS SHALL HAVE 2" LAP SEAMS TIGHTLY JOINED BY 3/8" STAINLESS STEELRIVETS OR GALVANIZED BOLTS ON 6" MAX. CENTERS.6.THE REINFORCED EDGES OF THE FOLLOWING SIZE END SECTIONS SHALL BE SUPPLEMENTED WITHGALVANIZED STEEL STIFFENER ANGLES:60" THRU 72" DIAMETER PIPE ...............2" X 2" X 1/4" ANGLE78" AND 84" DIAMETER PIPE, AND 77" X 52" & 83" X 57" PIPE ARCH ........... 2 1/2" X 2 1/2" X 1/4" ANGLETHE ABOVE GALVANIZED ANGLES SHALL BE ATTACHED BY 3/8" GALVANIZED NUTS AND BOLTS.7.GALVANIZED STEEL ANGLE REINFORCEMENT WILL BE PLACED UNDER THE CENTER PANEL SEAMSON THE 72" THRU 84" DIAM. PIPE AND 77" X 52" & 83" X 57" PIPE ARCH END SECTIONS.8.AS AN ALTERNATIVE TO THE CONNECTOR LUG AND THREADED ROD USED ON 12" THRU 24"CULVERT PIPE, THE ATTACHMENT MAY BE MADE WITH A 1" WIDE STRAP, 16 GAGE GALVANIZEDSTEEL FASTENED WITH A 1/2" DIAM., 6" LONG GALVANIZED BOLT AND ONE SQUAREHEAD NUT.SLOPE1NOTES:PIPEDIA.2"8"AATOE PLATEEXTENSIONHREINFORCED EDGE,SEE NOTE 6AWAGALVANIZEDSTEEL ORALUMINUM SKIRTPIPEBDIA.ORSPANLPIPE PAYMENTTO THIS POINT2"8"AATOE PLATEEXTENSIONHSPANRISEREINFORCED EDGE,SEE NOTE 6LH8"FILL SLOPEPIPETOE PLATE EXTENSION, WHENREQUIRED; GALVANIZEDSTEEL OR ALUMINUM, SAMEGAUGE AS SKIRT, LAPPED 2",FASTENED WITH 3/8" S.S. ORAL. RIVETS OR GALVANIZEDBOLTS ON 12" MAX. CENTERSTHREADEDRODPIPEEND SECTIONCONNECTOR LUG,SEE NOTESTYPE 2FOR 30" THRU 84" PIPEAND 35" x 24" THRU83" x 57" PIPE ARCH WITHANNULAR END CORRUGATIONSPIPEEND SECTIONTHREADED RODPIPE PAYMENTTO THIS POINTPIPECONNECTORSECTIONEND SECTION12"PIPE PAYMENTTO THIS POINTCONCRETE PIPE1" MIN. LAP AFTEREXPANSIONPIVOT BOLTEXPANDER LUGSMOOTH GALVANIZED STEELOR ALUMINUM PIPEPIPE PAYMENTTO THIS POINT5"LESS THAN 30" DIA., 7"30" DIA. AND OVER, 13"END SECTIONPIPE PAYMENTTO THIS POINTPIPEPIPE COUPLING BAND, SHOPBOLTED TO FLARED END SECTIONWITH 3/8" BOLTS AT 6" ON CENTER(MAX.) OR EQUIVALENT RIVETEDOR WELDED CONNECTION. FORUSE WITH ALL SIZES OF PIPE ANDPIPE ARCH WITH ANNULAR ENDSPIPEPIPE DIA.(INCHES)THICKNESS (INCHES)DIMENSION (INCHES)SKIRTENDSECTIONSLOPE (H:V)ABHLWTSTEELALUM.TOL. 35/641"MAX.TOL. 35/641"TOL. 35/641-1/2"TOL. 35/642"TOL. 35/642"120.0640.0606662124341 PC.2 1/2 : 1150.0640.0607862630401 PC.2 1/2 : 1180.0640.06081063136461 PC.2 1/2 : 1210.0640.06091263642521 PC.2 1/2 : 1240.0640.075101364148581 PC.2 1/2 : 1300.0790.075121685160702 PC.2 1/2 : 1360.0790.105141996072942 PC.2 1/2 : 1420.1090.10516221169841062 PC.2 1/2 : 1480.1090.10518271278901122 PC.2 1/2 : 1540.109---183012841021222 PC.2 1/2 : 1600.1090.138---183312871141343 PC.1 3/4 : 1660.1090.138---183612871201423 PC.1 1/2 : 1720.1090.138---183912871261463 PC.1 1/3 : 1780.1090.138---184212871321523 PC.1 1/4 : 1840.1090.138---184512871381583 PC.1 1/6 : 1PIPE ARCHPIPE ARCHDIMENSION(INCHES)THICKNESS (INCHES)DIMENSION (INCHES)SKIRTENDSECTIONSLOPE (H:V)ABHLWTSPANRISESTEELALUM.TOL. 35/641"MAX.TOL. 35/641"TOL. 35/641-1/2"TOL. 35/642"TOL. 35/642"17130.0640.0607961930401 PC.2 1/2 : 121150.0640.06071062336461 PC.2 1/2 : 124180.0640.06081262842521 PC.2 1/2 : 128200.0640.07591463248581 PC.2 1/2 : 135240.0790.075101663960701 PC.2 1/2 : 142290.0790.105121884675852 PC.2 1/2 : 149330.1090.1051321953851032 PC.2 1/2 : 157380.1090.1380.10518261263901143 PC.2 1/2 : 164430.1090.1380.105183012701021303 PC.2 1/2 : 171470.1090.1380.135183312771141463 PC.2 1/2 : 177520.1090.138---183612771261523 PC.1 3/4 : 183570.1090.138---183912771381583 PC.1 1/2 : 1ATWAWTFLARED END SECTIONSSTD. PLAN - 221.10PUBLIC WORKSDEPARTMENTAPPROVED:DATEGregg ZimmermanPublic Works AdministratorUNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA6388789/28/2018 | 9:45 AM PDT GENERAL NOTES: 7" COUPLING BAND 12" OR 24" COUPLING BAND MATERIAL TO BE ASTM A 36 1/4" PLATE GALVANIZED AFTER FABRICATION PER ASTM A123 all holes 3/4" diam. slots to be 119/32 x 3/4" SMOOTH COUPLING BAND FOR SMOOTH PIPE PLATE DETAIL ANCHOR ASSEMBLY CORRUGATED METAL PIPE 12" 3" R1" (TYP.)R1" (TYP.) 2" 6 5/8" 4 1/8" 3/4" 7/8" 1 7/8"1 7/8" 4 1/2"4 1/2" 12" PIPE STAKE (TYP.) COUPLING BAND WELD PLATE (SEE DETAIL) MATERIAL TO BE ASTM A36 GALVANIZED AFTER FABRICATION PER ASTM A153 WELD FLATTEN TO POINT 1" 1 1/2" x 6' PIPE STAKES EACH SIDE OF CULVERT 1.THE SMOOTH COUPLING BAND SHALL BE USED IN COMBINATION WITH CONCRETE PIPE. 2.CONCRETE PIPE WITHOUT BELL AND SPIGOT SHALL NOT BE INSTALLED ON GRADES IN EXCESS OF 20%. 3.THE FIRST ANCHOR SHALL BE INSTALLED ON THE FIRST SECTION OF THE LOWER END OF THE PIPE AND REMAINING ANCHORS EVENLY SPACED THROUGHOUT THE INSTALLATION. 4.IF THE PIPE BEING INSTALLED HAS A MANHOLE OR CATCH BASIN ON THE LOWER END OF THE PIPE, THE FIRST PIPE ANCHOR MAY BE ELIMINATED. 5.WHEN CMP IS USED, THE ANCHORS MAY BE ATTACHED TO THE COUPLING BANDS USED TO JOIN THE PIPE AS LONG AS THE SPECIFIED SPACING IS NOT EXCEEDED. 6.ALL PIPE ANCHORS SHALL BE SECURELY INSTALLED BEFORE BACKFILLING AROUND THE PIPE. PIPE ANCHOR REQUIREMENTS AND MAXIMUM PIPE SLOPES PIPE MATERIAL MINIMUM ANCHOR SPACING PIPE SLOPE ABOVE WHICH PIPE ANCHORS REQUIRED MAXIMUM PIPE SLOPE ALLOWED STEEL OR PVC1 1 ANCHOR PER 100 LF OF PIPE 20%30%3 CONCRETE, CPE, OR PP1 1 ANCHOR PER 50 LF OF PIPE 10%20%3 DUCTILE IRON2 1 ANCHOR PER PIPE SECTION 20%NONE SOLID WALL HDPE2 1 ANCHOR PER 100 LF OF PIPE, CROSS-SLOPE INSTALLATIONS ONLY 20%NONE NOTES: 1 THESE MATERIALS ARE NOT ALLOWED IN LANDSLIDE HAZARD AREAS. 2 BUTT-FUSED OR FLANGED PIPE JOINTS ARE REQUIRED; ABOVE GROUND INSTALLATION IS RECOMMENDED ON SLOPES GREATER THAN 40%. 3 A MAXIMUM SLOPE OF 200% IS ALLOWED FOR THESE PIPE MATERIALS WITH NO JOINTS (ONE SECTION), WITH STRUCTURES AT EACH END, AND WITH PROPER GROUTING CORRUGATED METAL PIPE COUPLING AND GENERAL PIPE ANCHOR ASSEMBLY STD. PLAN - 221.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT 6" MIN. 2' MIN. 6" MIN. 3' MIN. PIPE BEDDING CONCRETE BLOCK A B STRAP FOOTING ANCHOR 6" MIN. (TYP.) 12" MIN. 6" MIN. 6" MIN. CONCRETE FOOTING KEYED INTO UNDISTURBED SOIL AS SHOWN GENERAL NOTES: 1.FOR SOLID WALL HDPE PIPE LAID ON THE SURFACE, PIPE MUST BE FREE TO SLIDE INSIDE A 4' LONG SECTION OF PIPE ONE SIZE DIAMETER LARGER. 1" MIN. DIA. STEEL ROD (STRAP) CLAMPED SECURELY TO PIPE CONCRETE FOOTING KEYED INTO UNDISTURBED SOIL AS SHOWN 6" MIN. 12" MIN.2 x PIPE DIA. MIN. SECTION A CONCRETE BLOCK ANCHOR SECTION B PIPE ANCHOR REQUIREMENTS AND MAXIMUM PIPE SLOPES PIPE MATERIAL MINIMUM ANCHOR SPACING PIPE SLOPE ABOVE WHICH PIPE ANCHORS REQUIRED MAXIMUM PIPE SLOPE ALLOWED STEEL OR PVC1 1 ANCHOR PER 100 LF OF PIPE 20%30%3 CONCRETE, CPE, OR PP1 1 ANCHOR PER 50 LF OF PIPE 10%20%3 DUCTILE IRON2 1 ANCHOR PER PIPE SECTION 20%NONE SOLID WALL HDPE2 1 ANCHOR PER 100 LF OF PIPE, CROSS-SLOPE INSTALLATIONS ONLY 20%NONE NOTES: 1 THESE MATERIALS ARE NOT ALLOWED IN LANDSLIDE HAZARD AREAS. 2 BUTT-FUSED OR FLANGED PIPE JOINTS ARE REQUIRED; ABOVE GROUND INSTALLATION IS RECOMMENDED ON SLOPES GREATER THAN 40%. 3 A MAXIMUM SLOPE OF 200% IS ALLOWED FOR THESE PIPE MATERIALS WITH NO JOINTS (ONE SECTION), WITH STRUCTURES AT EACH END, AND WITH PROPER GROUTING STRAP PIPE ANCHOR STD. PLAN - 221.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT ANNULAR CORRUGATED BAND BAND ANGLE CONNECTOR DETAIL REFORMED PIPE ENDS W 1/2" x 6" BOLT (TYP.) BAND LAP NOT SHOWN FOR CLARITY (TYP.) COUPLING BAND DIMENSIONS (ALL DIMENSIONS ARE IN INCHES) BAND TYPE CORRUGATION PITCH x DEPTH PIPE DIA.MIN. W GASKET TYPE STEEL D 2 2/3 x 1/2 OR 3 x 1 REFORMED TO 2 2/3 x 1/2 12 - 84 12 SLEEVE 3 x 1 REFORMED TO 2 2/3 x 1/2 90 - 144 24 SLEEVE ALUMINUM D 2 2/3 x 1/2 12 - 72 12 SLEEVE 3 x 1 REFORMED TO 2 2/3 x 1/2 36 - 60 12 SLEEVE 66 - 108 24 SLEEVE SEMI-CORRUGATED BAND REFORMED PIPE ENDS W BAR & STRAP CONNECTOR DETAIL BAND ANGLE CONNECTOR DETAIL 1/2" x 6" BOLT (TYP.) COUPLING BAND DIMENSIONS (ALL DIMENSIONS ARE IN INCHES) BAND TYPE CORRUGATION PITCH x DEPTH PIPE DIA.MIN. W GASKET TYPE STEEL F 2 2/3 x 1/2 OR 3 x 1 REFORMED TO 2 2/3 x 1/2 12 - 84 10 1/2 O-RING ALUMINUM F 2 2/3 x 1/2 12 - 48 10 1/2 O-RING TYPE D TYPE F COUPLING BANDS FOR CORRUGATED METAL PIPES STD. PLAN - 221.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PIPES AND STRUCTURAL PLATE PIPES - STEP MITERED PIPE PIPES AND STRUCTURAL PLATE PIPES - FULL MITERED PIPE STRUCTURAL PLATE PIPE ARCHES AND UNDERPASSES NOTES: SECTION A ANCHOR BOLT DETAIL 1.THE VARIABLE DIMENSION INDICATED FOR THE HEIGHT OF STEP FOR STEP MITERED PIPES SHALL CONFORM TO THE MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFIED DIFFERENTLY ON THE PLANS OR IN THE SPECIAL PROVISIONS. 2.REINFORCING STEEL SHALL HAVE 1 1/2" MIN. CLEAR COVER TO ALL CONCRETE SURFACES. 3.HEADWALLS FOR CONCRETE CULVERT PIPE MAY OMIT ANCHOR BOLT ATTACHMENT. 4.WHEN STEEL PIPE SAFETY BARS ARE USED, HEADWALL THICKNESS SHALL BE INCREASED TO 8". 6" 2" FILL SLOPE, VARIABLE 24" SPLICE 6" 3" 24" VARIES, SEE NOTE 1 #4 BARS, EQUALLY SPACED, 16" MAX. CENTER TO CENTER (TYP.) S/4 S 2" #4 BARS, EQUALLY SPACED, 16" MAX. CENTER TO CENTER 2" S/4 S/4 S+S/2 COMMERCIAL CONCRETE ANCHOR BOLTS, EQUALLY SPACED, 24" MAX. CENTER TO CENTER (TYP.), SEE NOTE 3 6" 2" FILL SLOPE, VARIABLE 24" SPLICE 6" 3" 24" VARIES, SEE NOTE 1 #4 BARS, EQUALLY SPACED, 16" MAX. CENTER TO CENTER (TYP.) D/4 2" #4 BARS, EQUALLY SPACED, 16" MAX. CENTER TO CENTER 2" D/4 D/4 D+D/2 COMMERCIAL CONCRETE ANCHOR BOLTS, EQUALLY SPACED, 24" MAX. CENTER TO CENTER (TYP.), SEE NOTE 3 D 6" 2" FILL SLOPE, VARIABLE 24" SPLICE 6" 3" 24" VARIES, SEE NOTE 1 #4 BARS, EQUALLY SPACED, 16" MAX. CENTER TO CENTER (TYP.) D/4 2" #4 BARS, EQUALLY SPACED, 16" MAX. CENTER TO CENTER 2" D/4 D/4 D+D/2 COMMERCIAL CONCRETE ANCHOR BOLTS, EQUALLY SPACED, 24" MAX. CENTER TO CENTER (TYP.), SEE NOTE 3 D 2 1/2" 6" 3/4" BOLT FILL SLOPE ANCHOR BOLT (TYP.), SEE DETAIL AND NOTE 3 PIPE 6" D+D/2 OR S+S/2AAA HEADWALLS FOR CULVERT PIPE AND UNDERPASS STD. PLAN - 222.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 8" 8" D/4 NOTES: ISOMETRIC VIEW STEEL PLATE DETAIL 1/4 6" 24" 1.SOCKETS SHALL BE 3" EXTRA STRONG STEEL PIPE (3 1/2" O.D.). SOCKETS MUST BE THE PROPER ANGLE AND HEIGHT SO THAT SAFETY BARS ARE PARALLEL WITH HEADWALL AND SIDE SLOPE, AND ARE EASILY REMOVABLE. 2.SAFETY BARS SHALL BE 4" EXTRA STRONG STEEL PIPE (4 1/2" O.D.), OR 4 1/2" O.D. (0.250" WALL THICKNESS) STEEL TUBING. LENGTH (20' MAXIMUM) SHALL BE THE MINIMUM REQUIRED TO ACHIEVE RESIN BONDED ANCHOR PLACEMENT IN FULL DEPTH CONCRETE. WHEN MULTIPLE BARS ARE REQUIRED (SEE TABLE) PLACE BARS AT EQUAL SPACING (30" MAX.). 3.BEVEL CULVERT PIPE TO MATCH SIDE SLOPE. 4.RESIN BONDED ANCHORS SHALL BE 7" IN LENGTH (5" EMBEDMENT). 5.CENTERLINE OF HEADWALL SHALL BE NORMAL TO ROADWAY CENTERLINE. TOP VIEW CULVERT IS PERPENDICULAR TO ROADWAY STEEL PLATE, SEE DETAIL HEADWALL, SEE NOTE 5 FIELD CUT CULVERT TO MATCH BLOCKOUT IN HEADWALL NOTCH BOTTOM OF CULVERT PIPE TO ALLOW ANCHOR/SOCKET PLACEMENT (TYP.) 6" D/4 D/4 D TOP VIEW CULVERT IS SKEWED TO ROADWAY 2" (TYP.) 2" (TYP.) 4" (TYP.) 3" 18" 3" 1"x4" SLOT WITH 2" HOLE AT BOTTOM (TYP.) 8"x24"x5/8" STEEL PLATE 3/4" RESIN BONDED ANCHOR (TYP), SEE NOTE 4 SAFETY BAR 9"9" 4.5" DEEP KNOCKOUT PLACE RESIN BONDED ANCHORS IN FULL DEPTH CONCRETE (TYP.), SEE NOTE 4 SLOPE TO MATCH SIDE SLOPE HEADWALL, COMMERCIAL CONCRETE CULVERT PIPE OR PIPE ARCH, SEE NOTE 3 SAFETY BAR, SEE NOTE 2 CUT AND WELD SOCKET, SEE NOTE 1. SOCKET SHALL EXTEND INTO SAFETY BAR 4" 3/4" DIA.x16" THREADED ROD CENTERED THROUGH PIPE, SECURED WITH NUTS; OR 3/4"x6" ANCHOR STUDS WELDED TO PIPE. SPACING SHALL BE 8" FROM TOP AND 8" FROM BOTTOM OF CONCRETE (TYP.) STEEL PLATE, SEE DETAIL HEADWALL, SEE NOTE 5 6" D D/4 4" MIN. CULVERT DIA.NUMBER OF BARS REQUIRED UP TO 36"NONE 42" - 60"1 66" - 90"2 96" - 120"3 SECTION A ISOMETRIC CUTAWAY A TYPE 1 SAFETY BARS FOR STEPPED CULVERT PIPE OR PIPE ARCH STD. PLAN - 222.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1/4 3 NOTES: SIDE VIEW FRONT VIEW ISOMETRIC VIEW SECTION C SEE NOTE 3 1 SECTION A 1.D = INSIDE DIAMETER OF CULVERT PIPE, OR PIPE ARCH SPAN WIDTH, 36" MAXIMUM. 2.THE DISTANCE BETWEEN THE SAFETY BARS, AND BETWEEN THE TOP BAR AND THE CULVERT CROWN, SHALL BE EQUAL SPACES OF NO MORE THAN 24". THE DISTANCE MAY VARY 35/64" (±1") BETWEEN BARS TO FACILITATE PLACEMENT. 3.SLOPE SHALL MATCH SIDE SLOPE; 6H:1V PREFERRED, NOT STEEPER THAN 4H:1V. 8" D/4 SEE NOTE 2 SEE NOTE 2 SEE NOTE 2 24" 6" 8" CULVERT INVERT CULVERT CROWN FINISHED GROUND FIELD CUT PIPE BEVEL 10" (TYP.) 1 1/2" (TYP.) 3 1/2" (TYP.) 4" (TYP.) 1" MAX.1" MAX. 3/4" MAX. (TYP.) D-2", SEE NOTE 1 8" INSTALL RESIN BONDED ANCHOR (TYP.) 5 3/4"x3/4" DIA. THREADED ROD, 4" EMBEDMENT WITH HEX HEAD NUT (TYP.) 10" (TYP.) 1 1/2" (TYP.) 3 1/2" (TYP.) 4" (TYP.) 1" MAX.1" MAX. 3/4" MAX. (TYP.) D-2", SEE NOTE 1 8" INSTALL RESIN BONDED ANCHOR (TYP.) 5 3/4"x3/4" DIA. THREADED ROD, 4" EMBEDMENT WITH HEX HEAD NUT (TYP.) SECTION B 3 1/2" VARIES 7/8" DIA. HOLE 3/8" x 4" x 10" STEEL PLATE 3" x 3" x 5/16" STRUCTURAL TUBING (TYP.) D/4 D SEE NOTE 1 D/4 HEADWALL, SEE STD. PLAN 222.00 FOR DETAILS SAFETY BAR (TYP.) RESIN BONDED ANCHOR (TYP.) 3 1/2" x 3 1/2" BLOCKOUT (TYP.), FIELD CUT CULVERT TO MATCH BLOCKOUT IN HEADWALL CULVERT PIPE OR PIPE ARCHABC CTYPE 2 SAFETY BARS FOR CULVERT OR PIPE ARCH (ON CROSS ROADS) STD. PLAN - 222.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SECTION A PLAN VIEW NOTES: 1.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 2.CONTRACTOR TO VERIFY DIMENSIONS. A 3/4" DIA. BAR FRAME 4" CLEAR SPACING INSERT ALUMINUM TRASH RACK INTO BEVELED PIPE END GROUND SURFACE GROUND SURFACE 3" MIN. 4" CLEAR SPACING 4" CLEAR SPACING FLOW 45° ROLLED SMOOTH 16 GA. ALUMINUM PLATE TO FIT INNER DIAMETER OF PIPE 9" 1/4"x2" F.B. ANCHOR STRAPS. FASTEN WITH 1/2" GALVANIZED OR NON-CORROSIVE BOLTS AND NUTS (TYP., 4 PLACES) INSERT ALUMINUM TRASH RACK INTO BEVELED PIPE END 6" CLEAR FROM DEBRIS BARRIER TO FINISHED GRADE 6" CLEAR FROM DEBRIS BARRIER TO FINISHED GRADE DEBRIS BARRIER STD. PLAN - 223.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.THIS TRENCH SHALL BE CONSTRUCTED SO AS TO PREVENT POINT DISCHARGE AND/OR EROSION. 2.TRENCHES MAY BE PLACED NO CLOSER THAN 50 FEET TO ONE ANOTHER, 10 FEET MINIMUM TO ANY BUILDING (100 FEET ALONG FLOWLINE). 3.TRENCH AND GRADE BOARD MUST BE LEVEL. ALIGN TO FOLLOW CONTOURS OF SITE. 4.SUPPORT POST SPACING AS REQUIRED BY SOIL CONDITIONS TO ENSURE GRADE BOARD REMAINS LEVEL. 5.15% MAX UNLESS OTHERWISE EVALUATED AND APPROVED, SEE SECTION C.2.1.1. 6.GRADE BOARD AND SUPPORT POST TO BE UNTREATED CEDAR OR RECYCLED PLASTIC. SPACE SUPPORT POSTS EVERY 10 FEET MINIMUM. 7.GEOTEXTILE TO BE NON-WOVEN TYPE FOR SEPARATION PER WSDOT 9-33.2(1). NOTES: INFLUENT PIPE (MAX DESIGN FLOW <0.5 CFS PER TRENCH) FLOW TO SECOND DISPERSAL TRENCH IF NECESSARY FLOW TO OTHER BRANCHING CB'S AS NECESSARY 12" MIN. 6" MIN. 12" MIN. 50' MAX. NOTCHED GRADE BOARD, 2"x2" NOTCHES, 18" O.C. 2" GRADE BOARD NOTCHES (TYP.)18" O.C. 2" (TYP.) 6" MIN. PERFORATED PIPE LAID FLAT/LEVEL 3/4" -1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5) 4"x4" SUPPORT POST, SEE NOTE 6 SECTION A 6" MIN. 12" MIN. 36" MAX. WRAP TRENCH SIDES WITH GEOTEXTILE (LEAVE TOP AND BOTTOM EXPOSED), SEE NOTE 7 GALVANIZED BOLT (TYP.) 2"x12" GRADE BOARD, SEE NOTE 6 NOTCH DETAIL PLAN A 15% MAX, SEE NOTE 5 15% M A X , S E E NOTE 5 TYPE 1 CB WITH SOLID COVER TYPE 1 CATCH BASIN (CB) WITH SOLID COVER CAPPED CLEANOUT WYE FROM PIPE END CAP OR PLUG EXPOSED ROCK, DO NOT FILL 50-FOOT DISPERSION TRENCH WITH NOTCHED BOARD STD. PLAN - 224.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT NOTES: 1.SEE STD. PLANS 220.00 AND 220.10 FOR PIPE MATERIALS AND MINIMUM COVER REQUIREMENTS. 2.THE ROOF AND FOOTING DRAIN SYSTEMS ARE PRIVATELY MAINTAINED. 3.FLOW PATTERN SHOULD BE TO THE NEAREST CB IF GRADE ALLOWS, OR TO THE NEXT DOWNSTREAM CB. 4.ROOF DRAIN COLLECTORS MUST BE ANALYZED FOR CAPACITY, SIZED FOR 25-YEAR PEAK FLOW. 5.PVC PIPE MUST BE SDR 35 OR THICKER AND MEET THE REQUIREMENTS OF ASTM D3034. 6.PVC PIPE USED IN PRIVATELY MAINTAINED DRAINAGE SYSTEMS MUST BE WHITE IN COLOR. 7.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 8.AREA DRAIN WITHIN CRAWL SPACE IS ALLOWED TO CONNECT INTO THE STORM DRAINAGE SYSTEM WITH THE FOLLOWING CONDITIONS: A.THE CONNECTION IS TO BE TIGHT LINED A MINIMUM OF 10' OUTSIDE OF THE FOUNDATION, AND IN NO CASE CONNECTED UPSTREAM OF THE FOOTING DRAIN SYSTEM FOR THE HOUSE. B.THE AREA DRAIN MUST BE ROUTED THROUGH A SUMP PUMP SYSTEM PRIOR TO CONNECTION TO THE PUBLIC STORM DRAINAGE SYSTEM TO HELP PREVENT BACKUP DURING SURCHARGE CONDITIONS. SD SD SD SD 6" DIA MIN. ROOF DRAIN STUB WITH CLEANOUT (TYP.) LOT LINE, TYP. PRIVATE TYPE I CATCH BASIN CITY STORM DRAIN (SD) SYSTEM CLEANOUT, TYP AT EVERY 90°, OR 2ND 45° BEND, AND AT 100' MAX. SPACING ON STRAIGHT SECTIONS ROOF DRAIN TO CONNECT INTO CITY CATCH BASIN (CB), MIN. SIZE TYPE I PRIVATE ROOF DRAIN COLLECTOR PIPE; 6" DIA MIN., 0.5% MIN. SLOPE, 2 FT MIN. COVER CURB, SIDEWALK R.O.W. LINE 5' MIN. (TYP.) HOUSE (TYP.) PRIVATE JOINT UTILITY EASEMENT 5' MIN. WIDTH PRIVATE STORM DRAIN (SD) SYSTEM, 8" MIN. DIA. PIPE, SEE NOTE 1 3' MIN. TYPICAL PRIVATE STORM DRAIN COLLECTION SYSTEM STD. PLAN - 225.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 12" 12" YARD DRAIN OR CATCH BASIN WITH SOLID LID 2' MIN. SECTION A PLAN ELEVATION HOUSE HOUSE 5' MIN.10' MIN.SEE NOTE 2 ROOF DOWNSPOUT WITH OVERFLOW WYE AND SPLASH BLOCK 6" DIA. MIN. PVC, SDR 35 PER ASTM D3034 6" MIN. FINE MESH SCREEN, SS304 10x10 OR SIMILAR 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 NON-WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 COMPACTED BACKFILL 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 6" MIN. 6" MIN. 12" MIN.APERFORATED PIPE TO BE LEVEL 3/4" TO 1-1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD SPECIFICATION SECTION 9-03.12(5) 12" MIN. ABOVE SEASONAL HIGH GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER FLEXIBLE GASKETED CAP PER ASTM D5926 NOTES: 1.15' MINIMUM SETBACK FROM INFILTRATION TRENCH TO BUILDINGS WITH CRAWL SPACES, BASEMENTS, OR ELEVATIONS BELOW THE OVERFLOW POINT. 2.REQUIRED TRENCH LENGTH VARIES DEPENDING ON SOIL TYPE, UP TO 100' MAX. WHEN LOCATED IN COARSE SANDS OR COBBLES, INFILTRATION TRENCHES MUST BE AT LEAST 20' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. WHEN LOCATED IN MEDIUM SANDS, INFILTRATION TRENCHES MUST BE AT LEAST 30' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. 3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 6" MIN. CLEANOUT PER STD. PLAN 226.00 24" MIN. SINGLE FAMILY ROOF DOWNSPOUT INFILTRATION TRENCH STD. PLAN - 225.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT TYPICAL CLEANOUT CONFIGURATION GENERAL NOTES: 1.CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2.ALL FITTINGS SHALL BE SOIL TIGHT. 3.CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4.CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. DESIGN PONDING ELEVATION SOIL TIGHT 45° BEND EXTEND CLEANOUT RISER 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN 4" STREAMBED COBBLES PER WSDOT 9-03.11(2) SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE, SEE NOTE 1 WYE MECHANICAL PLUG OR CONTINUED CONNECTION FERNCO GASKETED QUIK CAP OR SIMILAR CAST IRON FRAME AND COVER, SEE NOTE 3 CLEANOUT RISER, SEE NOTE 2 PAVED AREA (TYP.) TO OVERFLOW STRUCTURE OR STORM MAIN CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA NOTES: 1.DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2.CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3.FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR "DRAIN". 4.FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. CLEANOUT RISER, SEE NOTE 2 FRAME SECTION 10-1/2" DIA 4" 5/8"9" DIA 15" DIA 8-1/8" DIA 8-13/16" DIA 5/8" COVER SECTION MADE IN USA 1" PLAN VIEW PROD NO.3/4" FLAT FACE GOTHIC (2) 3/8"-16 SS SOCKET HEAD CAP SCREW (ALLENHEAD) W/WSHRS ON A 8" DIA BOLT CIRCLE (1) OPEN PICKHOLE 12"12" 4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03.12(4) 8" CLASS "B" ASPHALT, SEE NOTE 4 STORM SYSTEM CLEANOUT STD. PLAN - 226.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 12'/15' MAINTENANCE ACCESS ROADNOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.SEE STANDARD PLAN 234.10 FOR TYPICAL DETENTION POND CROSS SECTIONS. 3.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STANDARD PLAN 234.50. 4.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 5.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY. 6.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 5.1.1.1 OF THE RENTON SWDM. 7.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STANDARD PLAN 234.40. 8.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. POND DESIGN WATER SURFACE 15% MAX.FLOWTRACT LINES AS REQUIRED POND INLET 5' SETBACK MIN. 6" SEDIMENT STORAGEFLOW ACCESS RAMP INTO POND COMPACTED EMBANKMENT LEVEL BOTTOM FLOWFLOWEMERGENCY OVERFLOW SPILLWAY ROCK LINING CONTROL STRUCTURE ALTERNATE EMERGENCY OUTFLOW STRUCTURE FOR PONDS NOT REQUIRED TO PROVIDE A SPILLWAY TOE OF SLOPE QUARRY SPALL PAD 3H:1V MAX. 3H:1V MAX. 3H:1V MAX. TYPICAL DETENTION POND STD. PLAN - 234.00C234.10PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)A234.10 B 234.10 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SCALE: CROSS SECTION A 234.00NTS EMERGENCY OVERFLOW WS DESIGN WS EMERGENCY OVERFLOW SPILLWAY CROSS SECTION B HAS 2 OPTIONS OVERFLOW WSPOND DESIGN WS DESIGN WS NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STANDARD PLAN 234.50. 3.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 4.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY. 5.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 5.1.1.1 OF THE RENTON SWDM. 6.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STANDARD PLAN 234.40. 7.SEE SECTION 5.1.1.2 OF THE RENTON SWDM TO CALCULATE THE REQUIRED WEIR WIDTH. 8.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 9.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. DEBRIS BARRIER PER STD. PLAN 223.00 OVERFLOW WS 100 YR EMERGENCY OVERFLOW WATER SURFACE (WS) OUTLET FLOW CONTROL STRUCTURE PER STD. PLANS 237.00-237.20 6" SEDIMENT STORAGE TOP WIDTH OF BERM. 6' MIN. 12'-15' MIN FOR ACCESS ROAD 3 13 1 KEY, IF REQUIRED BERM EMBANKMENT 5' MIN. SETBACK PROPERTY LINE EXISTING GROUND CIRCUMFERENCE LENGTH OF OPENING FOR 100-YR FLOW FRAME/GRATE FOR SECONDARY INLET. PROVIDE VERTICAL BARS IN FRAME AT 4" O.C. (OTHER SYSTEMS ACCEPTABLE IF APPROVED BY THE CITY). SEE ALSO THE SEPARATE OVERFLOW STRUCTURE, STD. PLAN 234.20. 4" ASPHALT (FOR SPILLWAYS ON ACCESS ROADS) VARIES, SEE NOTE 7 100-YR EMERGENCY OVERFLOW WS 6" MIN. FREEBOARD OVERFLOW WS 3 1 3 1 1' ROCK LINING MAX STONE SIZE - 12" MEDIAN STONE SIZE - 8" MIN STONE SIZE - 4" COMPACTED EMBANKMENT ROCK LINING PER PER CROSS SECTION B DESIGN WS OVERFLOW WS SCALE: CROSS SECTION B 234.00NTS SCALE: CROSS SECTION C 234.00NTS SECTION AA EXISTING GROUND 6" MIN. FREEBOARD SEE NOTE 8 (TYP.)XXSEE STD. PLAN 234.40 FOR FENCE REQUIREMENTS TYPICAL DETENTION POND SECTIONS STD. PLAN - 234.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 1.DIMENSIONS ARE FOR ILLUSTRATION OF 54" DIAMETER CB. FOR DIFFERENT DIAMETER CB'S ADJUST TO MAINTAIN 45°ANGLE OF "VERTICAL" BARS AND 7" O.C. MAXIMUM SPACING OF BARS AROUND LOWER STEEL BAND. 2.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. PLAN VIEW NOTES: SECTION A A 3/4" DIAMETER SMOOTH BARS EQUALLY SPACED (4" O.C. MAX.) 4 HOOK CLAMPS EVENLY PLACED, SEE DETAIL PROVIDE MAINTENANCE ACCESS BY WELDING 4 CROSSBARS TO 4 VERTICAL BARS AS SHOWN. HINGE UPPER ENDS WITH FLANGES/BOLTS AND PROVIDE LOCKING MECHANISM (PADLOCK) ON LOWER END. LOCATE STEPS DIRECTLY BELOW 3/4" DIA. SMOOTH ROUND BARS WELDED EQUALLY SPACED. BARS SHALL BE WELDED TO UPPER AND LOWER BANDS (24 BARS EVENLY SPACED, SEE NOTE 1) LOWER STEEL BAND 3/4" x 4" WIDE FORMED TO FIT IN GROOVE OF CATCH BASIN RISER 15° (TYP.), SEE NOTE 1 24", SEE NOTE 1 UPPER STEEL BAND 3/4" x 4" WIDE STANDARD STEPS OR LADDER, SEE NOTE 2 TYPE 2 CB SMOOTH VERTICAL BARS HOOK CLAMP ANCHORED TO CATCH BASIN RISER CATCH BASIN (CB) RISER 45° HOOK CLAMP DETAIL OVERFLOW STRUCTURE / RISER WITH DEBRIS BARRIER STD. PLAN - 234.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT Stormwater Pond This pond is in our care. Runoff is held here after storms. It is released slowly or stored until the next storm when it is replaced by incoming flows. This helps prevent downstream flooding and erosion and helps clean the water. For more information or to report littering, vandalism or other problems, call the City of Renton, Public Works Department, Maintenance Division at (425) 430-7400. Pond Name and GIS Facility ID Number SPECIFICATIONS: SIZE:48 INCHES BY 24 INCHES MATERIAL:0.125-GAUGE ALUMINUM FACE:HP-700-O PERM KR M ITEM #62200M - BEIGE VINYL OR APPROVED EQUAL; DOL 6060 - UV/ANTI-GRAFFITI CLEAR OVERLAY FILM. LETTERING:SILK SCREEN ENAMEL WHERE POSSIBLE, OR VINYL LETTERS. COLORS:BEIGE BACKGROUND, TEAL LETTERS. TYPE FACE:HELVETICA CONDENSED. TITLE: 3 INCH; SUB-TITLE: 1 1 2 - INCH; TEXT: 1 INCH; OUTER BORDER: 1 8 INCH BORDER DISTANCE FROM EDGE: 1 4 - INCH; ALL TEXT 1 3 4 - INCH FROM BORDER. POSTS:PRESSURE TREATED, BEVELED TOPS, 1 2 - INCH HIGHER THAN SIGN INSTALLATION:SECURE TO CHAIN LINK FENCE IF AVAILABLE. OTHERWISE INSTALL TWO 4"X4" POSTS, PRESSURE TREATED, MOUNTED ATOP A GRAVEL BED, INSTALLED IN 30-INCH CONCRETE FILLED POST HOLES (8-INCH MINIMUM DIAMETER), WITH THE TOP SIGN NO HIGHER THAN 42 INCHES FROM GROUND SURFACE. PLACEMENT:FACE SIGN IN DIRECTION OF PRIMARY VISUAL OR PHYSICAL ACCESS. DO NOT BLOCK ANY ACCESS ROAD. DO NOT PLACE WITHIN 6 FEET OF STRUCTURAL FACILITIES (E.G. MANHOLES, SPILLWAYS, PIPE INLETS). POND NAME AND GIS FACILITY ID NUMBER: TO BE PROVIDED BY THE CITY DURING THE CONSTRUCTION PLAN APPROVAL. POND NAME IS THE NAME OF THE PROJECT ON THE APPROVED CIVIL CONSTRUCTION PLANS. NOTE: IF THE FACILITY HAS A LINER TO RESTRICT INFILTRATION OF STORMWATER, THE FOLLOWING NOTE MUST BE ADDED TO THE FACE OF THE SIGN: "THIS FACILITY IS LINED TO PROTECT GROUNDWATER QUALITY." IN ADDITION, THE BACK OF THE SIGN SHALL INCLUDE INFORMATION INDICATING WHICH FACILITIES ARE LINED, THE EXTENT OF THE LINING, THE LINER MATERIAL USED, THE LINER THICKNESS (IF CLAY OR TILL), AND THE TYPE AND DISTANCE OF THE MARKER ABOVE THE LINER (IF A GEOMEMBRANE). Public Works Department Surface Water Utility PUGET SOUND STARTS HERE LOGO SPECIFICATIONS: COLORS:ORANGE (R223, G96, B32); TEAL (R0, G142, B179) SPACING:KEEP ALL OTHER LOGOS, GRAPHICS, AND TYPE AT LEAST 1 UNIT AWAY FROM THE LOGO ON ALL SIDES. 1 UNIT IS THE HEIGHT OF THE SMALL CAP "A" IN THE LOGO AT ANY GIVEN SIZE. PERMANENT PUBLIC STORMWATER POND SIGN STD. PLAN - 234.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT Stormwater Pond This pond is in the care of the private property owner(s). Runoff is held here after storms. It is released slowly or stored until the next storm when it is replaced by incoming flows. This helps prevent downstream flooding and erosion and helps clean the water. For more information or to report littering, vandalism or other problems, call the City of Renton, Public Works Department, Maintenance Division at (425) 430-7400. Pond Name and GIS Facility ID Number SPECIFICATIONS: SIZE:48 INCHES BY 24 INCHES MATERIAL:0.125-GAUGE ALUMINUM FACE:HP-700-O PERM KR M ITEM #62200M - BEIGE VINYL OR APPROVED EQUAL; DOL 6060 - UV/ANTI-GRAFFITI CLEAR OVERLAY FILM. LETTERING:SILK SCREEN ENAMEL WHERE POSSIBLE, OR VINYL LETTERS. COLORS:BEIGE BACKGROUND, TEAL LETTERS. TYPE FACE:HELVETICA CONDENSED. TITLE: 3 INCH; SUB-TITLE: 1 1 2 - INCH; TEXT: 1 INCH; OUTER BORDER: 1 8 INCH BORDER DISTANCE FROM EDGE: 1 4 - INCH; ALL TEXT 1 3 4 - INCH FROM BORDER. POSTS:PRESSURE TREATED, BEVELED TOPS, 1 2 - INCH HIGHER THAN SIGN INSTALLATION:SECURE TO CHAIN LINK FENCE IF AVAILABLE. OTHERWISE INSTALL TWO 4"X4" POSTS, PRESSURE TREATED, MOUNTED ATOP A GRAVEL BED, INSTALLED IN 30-INCH CONCRETE FILLED POST HOLES (8-INCH MINIMUM DIAMETER), WITH THE TOP SIGN NO HIGHER THAN 42 INCHES FROM GROUND SURFACE. PLACEMENT:FACE SIGN IN DIRECTION OF PRIMARY VISUAL OR PHYSICAL ACCESS. DO NOT BLOCK ANY ACCESS ROAD. DO NOT PLACE WITHIN 6 FEET OF STRUCTURAL FACILITIES (E.G. MANHOLES, SPILLWAYS, PIPE INLETS). POND NAME AND GIS FACILITY ID NUMBER: TO BE PROVIDED BY THE CITY DURING THE CONSTRUCTION PLAN APPROVAL. POND NAME IS THE NAME OF THE PROJECT ON THE APPROVED CIVIL CONSTRUCTION PLANS. NOTE: IF THE FACILITY HAS A LINER TO RESTRICT INFILTRATION OF STORMWATER, THE FOLLOWING NOTE MUST BE ADDED TO THE FACE OF THE SIGN: "THIS FACILITY IS LINED TO PROTECT GROUNDWATER QUALITY." IN ADDITION, THE BACK OF THE SIGN SHALL INCLUDE INFORMATION INDICATING WHICH FACILITIES ARE LINED, THE EXTENT OF THE LINING, THE LINER MATERIAL USED, THE LINER THICKNESS (IF CLAY OR TILL), AND THE TYPE AND DISTANCE OF THE MARKER ABOVE THE LINER (IF A GEOMEMBRANE). Public Works Department Surface Water Utility PUGET SOUND STARTS HERE LOGO SPECIFICATIONS: COLORS:ORANGE (R223, G96, B32); TEAL (R0, G142, B179) SPACING:KEEP ALL OTHER LOGOS, GRAPHICS, AND TYPE AT LEAST 1 UNIT AWAY FROM THE LOGO ON ALL SIDES. 1 UNIT IS THE HEIGHT OF THE SMALL CAP "A" IN THE LOGO AT ANY GIVEN SIZE. PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) PERMANENT PRIVATE STORMWATER POND SIGN STD. PLAN - 234.35 DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 12'/15' MAINTENANCE ROADFLOWPOND INLET FLO W NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ON STORMWATER FACILITIES TO BE MAINTAINED BY THE CITY, A FENCE SHALL BE PLACED AT THE TOP OF THE BERM WITH THE MAINTENANCE ACCESS ROAD IN THE INSIDE OF THE FENCE; OR 5 FEET MIN. FROM TOP OF BERM IF THERE IS NO MAINTENANCE ACCESS ROAD. NO LANDSCAPING IS ALLOWED INSIDE THE FENCE. ON STORMWATER FACILITIES TO BE PRIVATELY MAINTAINED, THE FENCE MAY BE PLACED ALONG TRACT BOUNDARY UNLESS LANDSCAPING IS REQUIRED WITHIN TRACT TO SCREEN THE POND AND FENCE. 3.LANDSCAPING, SHALL BE PLANTED IN ACCORDANCE WITH THE REQUIREMENTS INCLUDED IN SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (SWDM), WHICH PRECLUDES LANDSCAPING IN ANY BERMS THAT IMPOUND WATER OR WITHIN 10 FEET OF ANY STRUCTURE. 4.LANDSCAPING IS PROHIBITED IN THE INSIDE SLOPE OF THE POND OR ON ANY BERMS THAT IMPOUND WATER. 5.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE RENTON SWDM. ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 5.1.1.1 OF THE RENTON SWDM. 6.ALL TREES AND OTHER PLANTINGS SHALL CONFORM TO THE RENTON SWDM REQUIREMENTS AND RESTRICTIONS REGARDING LOCATION OVER OTHER INFRASTRUCTURE SUCH AS WATER, SEWER, POWER, ETC. 7.FOR FENCES TO BE MAINTAINED BY THE CITY, SEE STD. PLANS 234.60 AND 234.70 FOR DETAILS. 8.WOOD FENCES ARE ALLOWED IN SUBDIVISIONS WHERE THE FENCE AND STORMWATER FACILITY WILL BE MAINTAINED BY HOMEOWNERS ASSOCIATIONS OR ADJACENT LOT OWNERS OR IN PRIVATE COMMERCIAL OR INDUSTRIAL SITES WHERE THE FENCE AND STORMWATER FACILITY WILL BE PRIVATELY MAINTAINED. THE WOOD FENCE SHALL BE PLACED ON PRIVATE PROPERTY. 9.WOOD FENCES (WHEN ALLOWED BY THE CITY) SHALL HAVE PRESSURE-TREATED POST (GROUND CONTACT RATED) EITHER SET IN 24-INCH DEEP CONCRETE FOOTINGS OR ATTACHED TO FOOTINGS BY GALVANIZED BRACKETS. RAILS AND FENCE BOARDS SHALL BE CEDAR OR PRESSURE-TREATED FIR OR HEMLOCK. 10.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. LANDSCAPING ALLOWED PER SECTION 5.1.1.1 OF THE RENTON SWDM SOD OR SEED WITH APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE RENTON SWDM ONLY GRASS AND/OR SMALL SHRUBS MAY BE ALLOWED. IF NO LANDSCAPING IS PROPOSED AND FENCE IS LOCATED IN TRACT LINE, THEN ONLY GRASS IS ALLOWED IN THIS SECTION. OWNERSHIP OF STORMWATER TRACT IN RESIDENTIAL PLATS WITH PUBLIC STREETS: OWNERSHIP AND MAINTENANCE OF THE STORMWATER TRACT WILL BE THE RESPONSIBILITY OF THE PROPERTY OWNERS WITHIN THE SUBDIVISION. THE HOME OWNERS ASSOCIATIONS (HOA) WILL BE RESPONSIBLE FOR THE MAINTENANCE OF SAID STORMWATER TRACT EXCLUDING THE DRAINAGE FACILITIES CONTAINED THEREIN. A NOTE THAT ASSIGNS EACH PROPERTY OWNER AS HAVING EQUAL AND UNDIVIDED INTEREST OVER THE MAINTENANCE OF THE STORMWATER TRACT SHALL BE PLACED IN THE FINAL PLAT. AN OVERLYING EASEMENT UNDER AND UPON SAID DRAINAGE TRACT SHALL BE CONVEYED TO THE CITY OF RENTON FOR THE PURPOSE OF OPERATING, MAINTAINING, IMPROVING, REPLACING AND KEEPING IN GOOD REPAIR THE DRAINAGE FACILITIES CONTAINED THEREIN. IF NO LANDSCAPING IS PROPOSED IN THE STORMWATER TRACT, THEN THE STORMWATER TRACT CAN BE DEDICATED TO THE CITY. ALL OTHER FACILITIES ARE TO BE PRIVATELY OWNED AND MAINTAINED. 5' SETBACK POND DESIGN WATER SURFACE TRACT BOUNDARY 6" SEDIMENT STORAGE ACCESS RAMP EMERGENCY OVERFLOW SPILLWAY ROCK LINING CONTROL STRUCTURE 3:1 MIN. SIDE SLOPES. VERTICAL WALLS ALLOWED. FENCE REQUIRED ON TOP OF WALL FENCE LOCATION AS REQUIRED. REFER TO NOTES FOR FENCE LOCATION ON DEVELOPMENTS PROPOSING LANDSCAPING WITHIN STORMWATER TRACTS LEGEND: LANDSCAPING, TREES, POND GEOMETRY, AND FENCING DETAILS STD. PLAN - 234.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.ACCESS ROADS SHALL BE LOCATED IN THE STORMWATER TRACT OR PUBLIC RIGHT-OF-WAY AND SHALL BE CONNECTED TO AN IMPROVED PUBLIC RIGHT-OF-WAY. 2.MAINTENANCE ACCESS ROAD(S) SHALL BE PROVIDED TO THE CONTROL STRUCTURE AND OTHER DRAINAGE STRUCTURES ASSOCIATED WITH THE POND (E.G., INLET, EMERGENCY OVERFLOW, OR BYPASS STRUCTURES). MANHOLE AND CATCH BASIN LIDS MUST BE IN OR AT THE EDGE OF THE ACCESS ROAD AND AT LEAST THREE FEET FROM A PROPERTY LINE. RIMS SHALL BE SET AT THE ACCESS ROAD GRADE. 3.AN ACCESS RAMP IS REQUIRED FOR REMOVAL OF SEDIMENT WITH A TRACKHOE AND TRUCK. THE RAMP MUST EXTEND TO THE POND BOTTOM IF THE POND BOTTOM IS GREATER THAN 1,500 SQUARE FEET (MEASURED WITHOUT THE RAMP) AND IT MAY END AT AN ELEVATION 4 FEET ABOVE THE POND BOTTOM IF THE POND BOTTOM IS LESS THAN 1,500 SQUARE FEET (MEASURED WITHOUT THE RAMP), PROVIDED THE POND SLOPES ARE 3H:1V OR FLATTER. 4.THE INTERNAL BERM OF A WETPOND OR COMBINED DETENTION AND WETPOND MAY BE USED FOR ACCESS IF IT IS NO MORE THAN 4 FEET ABOVE THE FIRST WETPOOL CELL, IF THE FIRST WETPOOL CELL IS LESS THAN 1,500 SQUARE FEET (BOTTOM AREA MEASURED WITHOUT THE RAMP), AND IF IT IS DESIGNED TO SUPPORT A LOADED TRUCK, CONSIDERING THE BERM IS NORMALLY SUBMERGED AND SATURATED. 5.ACCESS SHALL BE LIMITED BY A DOUBLE-POSTED GATE IF A FENCE IS REQUIRED, OR BY BOLLARDS. BOLLARDS SHALL BE DESIGNED IN ACCORDANCE WITH THE CITY OF RENTON STANDARD PLANS. 6.ACCESS ROADS AND RAMPS SHALL MEET THE FOLLOWING DESIGN CRITERIA: 6.1.MAXIMUM GRADE SHALL BE 15% FOR ASPHALT PAVING AND 12% FOR GRAVEL. 6.2.OUTSIDE TURNING RADIUS SHALL BE 40 FEET MINIMUM. 6.3.FENCE GATES SHALL BE LOCATED ONLY ON STRAIGHT SECTIONS OF ROAD. 6.4.ACCESS ROADS AND RAMPS SHALL BE 15 FEET IN WIDTH ON CURVES AND 12 FEET ON STRAIGHT SECTIONS. 6.5.A PAVED APRON SHALL BE PROVIDED WHERE ACCESS ROADS AND RAMPS CONNECT TO PAVED PUBLIC ROADWAYS. THE APRON SHALL BE CONSISTENT WITH DRIVEWAY DETAILS IN THE CITY OF RENTON STANDARD PLANS. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 7.ACCESS ROADS AND RAMPS SHALL BE CONSTRUCTED WITH EITHER THE GRAVEL ROAD OPTION OR ASPHALT ROAD OPTION. WHERE ACCESS ROADS AND RAMPS PASS OVER EMERGENCY OVERFLOW SPILLWAYS, AN HMA WEARING COURSE IS REQUIRED (SEE STANDARD PLAN 234.10). 8.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 4" CRUSHED SURFACING TOP COURSE (CSTC) PER WSDOT STD. SPEC 9-03.9(3) 12" QUARRY SPALLS PER WSDOT STD. SPEC 9-13.1(5) 4" HOT MIX ASPHALT (HMA) 6" CRUSHED SURFACING BASE COURSE (CSBC) PER WSDOT STD. SPEC 9-03.9(3) 12' OR 15', SEE NOTE 6.4 12' OR 15', SEE NOTE 6.4 GRAVEL ROAD OPTION ASPHALT ROAD OPTION WOVEN GEOTEXTILE FABRIC FOR SEPARATION PER TABLE 3 FROM WSDOT STD. SPEC 9-33.2(1) ACCESS ROAD AND RAMP STD. PLAN - 234.50 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT GENERAL NOTES:1.FENCE MATERIAL SHALL BE 9 GAUGE GALVANIZED STEEL FABRIC WITH BONDED VINYL COATING. VINYL COATING SHALL BE COMPATIBLE WITH THE SURROUNDING ENVIRONMENT AS APPROVED BY THE CITY (E.G.GREEN IN OPEN, GRASSY AREAS AND BLACK IN WOODED AREAS). ALL POSTS, CROSS BARS, AND GATES SHALL BE PAINTED OR COATED THE SAME COLOR AS VINYL CHAIN LINK FENCE.2.UNLESS OTHERWISE SPECIFIED ON STD. PLAN 234.60 OR 234.70, STANDARD MATERIALS USED IN CONSTRUCTION OF CHAIN LINK FENCE AND GATES SHALL BE IN ACCORDANCE WITH WSDOT STD. SPEC SECTION 9-16.1.3.ALONG THE TOP AND BOTTOM, USING WIRE TIES AND HOG RINGS, FASTEN THE CHAIN LINK FENCE FABRIC TO THE TOP RAIL AND TENSION WIRE WITHIN THE LIMITS OF THE FIRST FULL FABRIC WEAVE.4.WITHIN 10 FEET OF A TRAVELED LANE, USE TENSION WIRE INSTEAD OF A TOP RAIL.5.BOTH SIDES OF A CORNER POST SHALL CONNECT TO A PULL POST (SEE END DEPICTION).6.IF SOIL ALLOWS, LINE POSTS MAY BE DRIVEN DIRECTLY INTO GROUND A MINIMUM OF 2'-6" INSTEAD OF USING CONCRETE POST BASE.LINE POSTGATEPOST, FRAME, AND RAIL SPECIFICATIONS(HIGH STRENGTH SCHEDULE 40 GALVANIZED PIPE)MEMBEROUTSIDE DIAMETER O.D.WEIGHT (LB/FT)GATE POST4"6.56END POST / CORNER POST /PULL POST2-7/8"4.64LINE POST2-3/8"3.12GATE FRAME1-7/8"2.28TOP RAIL1-5/8"1.83TIE WIRES (TYP.)SPACED @ 14" MAX.LINE POST SPACED@ 10' MAX.6' FABRICHEIGHT(TYP.)2'-6"(TYP.)TIE WIRES (TYP.)SPACED @14" MAX.CHAIN LINK FENCEFABRIC (TYP.)PULL POST(AT GATE)TENSIONWIRE (TYP.)3'-0" (TYP.)GATE POST12" ROUNDTRUSSROD (TYP.)TIE WIRES (TYP.)SPACED @14" MAX.MATCH FENCE SELVAGE (TYP.)MATCH FENCESELVAGE (TYP.)16'10'TOP HINGE ~180°SWING (TYP.)I234.70TOP RAIL (TYP.),SEE NOTE 4PULL POST(AT GATE)TENSIONWIRE (TYP.)BOTTOM HINGE~180° SWING (TYP.)18"HOG RINGS (TYP.)SPACED @ 24" MAX.J234.70K234.70FABRIC BAND WITHCARRIAGE BOLT AND NUT(TYP.) SPACED @ 15" MAXSTRETCHER BAR (TYP.)6'FABRICHEIGHT(TYP.)SEE NOTE 612" ROUND12" ROUND10" MIN. ROUND10" MIN.ROUNDG234.70H234.70E234.70GATE POSTGATE LATCHGATE FRAME (TYP.)E234.70F234.70CORNEREND10' MAX.END POSTTENSIONWIRE (TYP.)A234.70FABRIC BAND WITH CARRIAGEBOLT AND NUT (TYP.)SPACED @ 15" MAXSTRETCHERBAR (TYP.)TENSIONWIRE (TYP.)HOG RINGS (TYP.)SPACED @ 24" MAX.TOP RAIL (TYP.),SEE NOTE 4C234.703'-0"(TYP.)~1"TIE WIRES (TYP.)SPACED @14" MAX.CONCRETE POST BASE (TYP.)10" DIA MIN.KNUCKLEDSELVAGE (TYP.)PULL POST(AT END ORCORNER)B234.70D234.70CHAIN LINKFENCE FABRIC(TYP.)CORNER POST,SEE NOTE 56"(TYP.)6'FABRICHEIGHT(TYP.)PUBLIC WORKSDEPARTMENTAPPROVED:DATEMartin PastuchaPublic Works AdministratorUNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)POND FENCING AND GATESTD. PLAN - 234.60DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C1088/13/2020 | 8:48 AM PDT SCALE:DETAIL - GATE POST BOTTOMJ234.60NTSSCALE:DETAIL - PULL POST BOTTOM(AT GATE)K234.60NTSSCALE:DETAIL - GATE POST TOPI234.60NTSSCALE:DETAIL - LINE POST TOPG234.60NTSSCALE:DETAIL - LINE POST BOTTOMH234.60NTSTENSION WIRE (TYP.)TURNBUCKLEFABRIC BAND WITH CARRIAGEBOLT AND NUT (TYP.)SPACED @ 15" MAXSTRETCHER BAR (TYP.)EYE BOLTBOTTOM HINGESTRETCHER BAR (TYP.)FABRIC BAND WITH CARRIAGEBOLT AND NUT (TYP.)SPACED @ 15" MAXEYE BOLTTENSION WIRE (TYP.)EYE NUTTURNBUCKLETOP RAILTENSION WIRESTRETCHER BARGATE POSTGATE POSTPULL POSTLINE POSTTENSION WIRETOP RAILLINE POSTFABRIC BAND WITHCARRIAGE BOLT AND NUTSPACED @ 15" MAXTIE WIRES (TYP.)SPACED @ 14" MAX.TIE WIRESSPACED @ 14" MAX.HOG RINGS (TYP.)SPACED @ 24" MAX.HOG RINGSSPACED @ 24" MAX.HOG RINGS (TYP.)SPACED @ 24" MAX.TIE WIRES (TYP.)SPACED @ 14" MAX.SCALE:DETAIL - END POST TOPA234.60NTSSCALE:DETAIL - END POST BOTTOMB234.60NTSFABRIC BAND WITHCARRIAGE BOLT ANDNUT SPACED @ 15" MAXBRACE BANDWITH CARRIAGEBOLT AND NUTTOP RAILSTRETCHERBAREND POSTTIE WIRESSPACED @ 14" MAX.TURNBUCKLETENSION WIRE (TYP.)BRACE BAND WITHCARRIAGE BOLT AND NUTSTRETCHER BARFABRIC BAND WITHCARRIAGE BOLT ANDNUT SPACED @ 15" MAXEND POSTHOG RINGSSPACED @ 24" MAX.BRACE BAND WITHCARRIAGE BOLTAND NUT (TYP.)TOP HINGETRUSS RODTRUSS RODDOME TOPRAIL ENDDOME TOPEYE TOPRAIL ENDGATE FRAME(TYP.)GATE FRAME(TYP.)SCALE:DETAIL - PULL POST TOPC234.60NTSSCALE:DETAIL - PULL POST BOTTOM(AT END OR CORNER)D234.60NTSSCALE:DETAIL - CORNER POST TOPE234.60NTSSCALE:DETAIL - CORNER POST BOTTOMF234.60NTSTOP RAILBRACE BAND WITHCARRIAGE BOLT AND NUTFABRIC BAND WITHCARRIAGE BOLT AND NUT(TYP.) SPACED @ 15" MAXSTRETCHER BAR (TYP.)TENSIONWIRETENSION WIRE (TYP.)TWO-WAY BRACE BAND WITHCARRIAGE BOLTS AND NUTSFABRIC BAND WITHCARRIAGE BOLT AND NUT(TYP.) SPACED @ 15" MAXSTRETCHERBAR (TYP.)PULL POSTPULL POSTFABRIC BAND WITHCARRIAGE BOLTAND NUT (TYP.)SPACED @ 15" MAXBRACE BAND WITHCARRIAGE BOLTAND NUT (TYP.)TOP RAIL (TYP.)STRETCHERBAR (TYP.)CORNER POSTTURNBUCKLE (TYP.)TENSION WIRE (TYP.)BRACE BAND WITH CARRIAGEBOLT AND NUT (TYP.)STRETCHER BAR (TYP.)FABRIC BAND WITHCARRIAGE BOLT AND NUT(TYP.) SPACED @ 15" MAXCORNER POSTTIE WIRES (TYP.)SPACED @ 14" MAX.TIE WIRES (TYP.)SPACED @ 14" MAX.HOG RINGS (TYP.)SPACED @ 24" MAX.HOG RINGS (TYP.)SPACED @ 24" MAX.RAIL END (TYP.)DOME TOPEYE TOPPUBLIC WORKSDEPARTMENTAPPROVED:DATEMartin PastuchaPublic Works AdministratorUNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)POND FENCING AND GATE - POST DETAILSSTD. PLAN - 234.70DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C1088/13/2020 | 8:48 AM PDT "FLOW-THROUGH" SYSTEM SHOWN SOLID. DESIGNS FOR "FLOW BACKUP" SYSTEM AND PARALLEL TANKS SHOWN DASHED 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.MINIMUM TANK DIAMETER IS 36 INCHES. 3.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4.ACCESS RISERS REQUIRED WITHIN 50 FEET FROM ANY LOCATION IN THE DETENTION TANK AND WITHIN 5 FEET OF EACH TERMINAL END. ANY LOCATION WITHIN THE DETENTION TANK SHALL HAVE A DIRECT LINE OF SIGHT FROM AN ACCESS POINT, UNOBSTRUCTED BY ANY RESTRICTIONS SUCH AS A WALL OR BAFFLE. 5.H-20 LIVE LOADS MUST BE ACCOMMODATED FOR TANKS LYING UNDER PARKING AREAS, ROADWAYS, AND ACCESS ROADS. 6.BEDDING OF THE PIPE SHALL BE IN ACCORDANCE WITH STD. PLAN 220.00. 7.PRIOR TO STARTUP, DETENTION TANK SHALL PASS LEAK TEST. 8.PIPE MATERIAL, JOINTS, AND PROTECTIVE TREATMENT FOR TANKS SHALL BE IN ACCORDANCE WITH SECTIONS 7-04 AND 9-05 OF THE WSDOT/APWA STANDARD SPECIFICATION. 9.ALL TANK ACCESS OPENINGS MUST BE READILY ACCESSIBLE BY MAINTENANCE VEHICLES. 10.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 11.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. NOTES: SECTION A PLAN INLET PIPE (BACKUP SYSTEMS, WHERE ALLOWED) INLET PIPE (FLOW THROUGH) FLOW 2' MIN. 36" MIN. 36" MIN. CONNECTOR PIPE SAME SIZE AS INLET PIPE, 12" MIN. DIA. TYPE 2 CATCH BASIN (CB) REQUIRED FOR FLOW THROUGH SYSTEM ONLY PER STD. PLAN 201.00 OPTIONAL PARALLEL TANK ACCESS RISERS, SEE NOTE 4 ACCESS RISERS PER STD. PLAN 235.10 CONTROL STRUCTURE WITH SOLID LOCKING LID 2' MAX. 50' MAX.100' MAX. 6" SEDIMENT STORAGE 2' MIN. 2' MIN. 2" MIN. DIA. AIR VENT PIPE WELDED TO TANK (REQUIRED IF NO ACCESS RISER ON TANK) ACCESS RISERS, SEE STD. PLAN 235.10 36" MIN. DIA. (TYP.) CONTROL STRUCTURE (FROP-T SHOWN), MIN. 54" DIA. TYPE 2 CB PER STD. PLAN 237.00 DETENTION TANK (SIZE AS REQUIRED) A OUTLET PIPE FINISH GRADE 2' MIN. SEE NOTE 10 (TYP.) SEE NOTE 10 (TYP.) FLOW RESTRICTOR PER STD. PLAN 237.00 6" MIN. FLOW 5' MAX. TERMINAL END TYPICAL DETENTION TANK STD. PLAN - 235.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 1.USE ADJUSTING BLOCKS AS REQUIRED TO BRING FRAME TO GUIDE. 2.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 3.MUST BE LOCATED FOR ACCESS BY MAINTENANCE VEHICLES. 4.MAY SUBSTITUTE WSDOT SPECIAL TYPE IV MANHOLE (RCP ONLY). 5.TOP SLAB SHALL BE RATED FOR HS-20 LOADING. 6.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. PLAN SECTION STANDARD TYPE 2, 60" DIA. CATCH BASIN (CB) CONCRETE TOP SLAB 36" CMP RISER FRAME LOCKING LID (MARKED "DRAIN") MOUNTED OVER 24" DIA. ECCENTRIC OPENING 36" 24" MAX. 6" 24-INCH BOLT LOCKING RING AND COVER. ADJUSTMENT RINGS AS NECESSARY, PER STANDARD PLANS 204.40 AND 204.50 CRUSHED SURFACING TOP COURSE PER WSDOT STD. SPEC 9-03.9(3) COMPACTED TO 95% MAX DENSITY (TYP.) MANHOLE STEPS, 12" O.C. WELD OR BOLT STANDARD MANHOLE STEPS DETENTION TANK RISER, 36" DIA. MIN., SAME MATERIAL AND GAUGE AS TANK WELDED OR FUSED TO TANK NOTES: LADDER MAINTAIN 1" GAP BETWEEN BOTTOM OF SLAB AND TOP OF RISER. PROVIDE PLIABLE GASKET TO EXCLUDE DIRT PLACE CEMENT MORTAR SEAL BETWEEN TOP SLAB AND MANHOLE, SEE NOTE 6 Ø24" DETENTION TANK ACCESS STD. PLAN - 235.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT DESIGN WATER SURFACE OPTIONAL 5'x10' ACCESS VAULT MAY BE USED IN LIEU OF TOP ACCESS OUTLET PIPE 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 3.PROVIDE WATER STOP AT ALL CAST-IN-PLACE CONSTRUCTION JOINTS. PRECEAST VAULTS SHALL HAVE APPROVED RUBBER GASKET SYSTEM. 4.VAULTS <10' WIDE MUST USE REMOVABLE LIDS. 5.PREFABRICATED VAULT SECTIONS MAY REQUIRE STRUCTURAL MODIFICATIONS TO SUPPORT 5' X 10' OPENING OVER MAIN VAULT. ALTERNATIVELY, ACCESS CAN BE PROVIDED VIA A SIDE VESTIBULE AS SHOWN. 6.ALL VAULT AREAS MUST BE WITHIN 50' OF AN ACCESS POINT. 7.FOR VAULTS UNDER ROADWAYS, THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY, MULTIPLE STANDARD LOCKING MANHOLE COVERS MAY BE PROVIDED. SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER, TO FACILITATE REMOVAL OF SEDIMENT. LADDERS AND HAND-HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE. 8.MINIMUM DIAMETER FOR ALL ACCESS OPENINGS (RISERS), EXCEPT THOSE COVERED BY REMOVABLE PANELS, IS 36 INCHES. 9.VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 10.FOR RAISED OPENINGS WHERE THE DEPTH FROM THE IRON COVER TO THE TOP OF THE VAULT EXCEEDS 24 INCHES, AN ACCESS STRUCTURE EQUIVALENT TO A TYPE 2 CATCH BASIN OR TYPE 1 MANHOLE SHALL BE USED. 11.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 12.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. FLOW 5%5%FLOW 5' 10' 5'x10' REMOVABLE LOCKING PANEL FOR VAULTS GREATER THAN 1,250 SF OF FLOOR AREA FLOW WALL FLANGE, TYP 16" MAX. 4" MIN. 12" 12" 6" SEDIMENT STORAGE FRAMES, GRATES, AND ROUND SOLID COVERS MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 PLAN VIEW 6" MIN. 2' MIN. 2' MIN. 4' MIN. NOTES: HANDHOLDS, STEPS OR LADDER CAPACITY OF OUTLET PIPE NOT LESS THAN DEVELOPED 100 - YR DESIGN FLOW FLOW RESTRICTOR FLOW SECTION A A SUMP AREA SEE NOTE 11 (TYP.) SEE NOTE 11 (TYP.) 12" MIN. VENTILATION PIPE (TYP), SEE NOTE 9 ACCESS MANHOLE WITH 24" BOLT LOCKING RING AND COVER PER STD. PLANS 204.40 AND 204.50 4' MIN. SEE NOTE 11 (TYP.) SEE NOTE 11 (TYP.) 2' MIN. COVER, SEE NOTE 10 7' MIN. 5'x10' GRATE ACCESS DOORS OR REMOVABLE PANEL TYPICAL DETENTION VAULT STD. PLAN - 236.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT d ISOMETRIC SECTION A PLAN VIEW ELBOW RESTRICTOR DETAIL 1.USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2.OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. 3.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4.FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB-DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5.IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6.PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3'-0" VERTICAL SPACING). 7.LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8.LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10.IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. NOTES: 2" MIN. 6" MIN. 6" MAX. REMOVABLE WATERTIGHT COUPLING OR FLANGE PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED, SEE NOTE 3 DESIGN WATER SURFACE 16" MAX. 12" MIN. UNDER PAVEMENT 6" MIN. D 1.5 x D MIN.2' MIN. 2' MIN. 2' MIN. 12" 12" (TYP.) FRAME & SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 VERTICAL BAR GRATE FOR SECONDARY INLET HANDHOLDS, STEPS, OR LADDER SHEAR GATE WITH CONTROL ROD FOR CLEANOUT/DRAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER) PER STD. PLAN 237.30 INLET PIPEOUTLET PIPE, SEE NOTES 1 & 5 INVERT AND ELEVATION PER PLANS WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 2' MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS 2' MIN, ANGLE AS NECESSARY, SEE NOTE 7 ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WITH WATER ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 PIPE SUPPORTS, SEE NOTE 6 A ELEVATION PER PLANS SEE NOTE 9 (TYP.) 12" SECTION OF PIPE ATTACHED BY GASKETED BAND TO ALLOW REMOVAL FLOW CONTROL STRUCTURE - RESTRICTOR TEE STD. PLAN - 237.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 1.OUTLET CAPACITY: 100 YEAR DEVELOPED PEAK FLOW. 2.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 3.CATCH BASIN: TYPE 2 MINIMUM 72" DIAMETER TO BE CONSTRUCTED IN ACCORDANCE WITH STD. PLAN 201.00 UNLESS OTHERWISE SPECIFIED. 4.ORIFICES: SIZED AND LOCATED AS REQUIRED WITH LOWEST ORIFICE A MINIMUM OF 2' FROM BASE. 5.BAFFLE WALL SHALL HAVE #4 BAR AS 12" SPACING EACH WAY. 6.PRECAST BAFFLE WALL SHALL BE KEYED AND GROUTED IN PLACE. 7.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. NOTES: DESIGN WS FLOW MAX. WATER SURFACE (WS) OVERFLOW CONDITIONS 12" MIN. 16" MAX. 12" MIN. UNDER PAVEMENT 6" FRAME ELEVATION PER PLANS FRAME AND ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 ELBOW RESTRICTORS, SEE DETAIL 2' MIN. 2' MIN. SECTION A SECTION B 2' MIN. 6" MIN. ATTACH SHEAR GATE CONTROL ROD TO SUPPORT BRACKET ON INSIDE OF ACCESS OPENING SHEAR GATE WITH CONTROL ROD FOR DRAIN PER STD. PLAN 237.30 ORIFICE PLATE 10 GAUGE MIN. NON-GALVANIZED CORROSION RESISTANT MATERIAL WITH ORIFICE DIA 1" MINIMUM LESS THAN DIA OF CONCRETE HOLE HANDHOLDS, STEPS, OR LADDER REMOVABLE WATERTIGHT COUPLING GROUTED PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED 6" MIN. 6" MAX. PLAN ISOMETRIC ELBOW RESTRICTOR DETAIL A BSEE NOTE 7 (TYP.) FLOW CONTROL STRUCTURE - CONTROL BAFFLE STD. PLAN - 237.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT DESIGN WS 1.OUTLET CAPACITY: 100 YEAR DEVELOPED PEAK FLOW. 2.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 3.CATCH BASIN: TYPE 2 MINIMUM 72" DIAMETER TO BE CONSTRUCTED IN ACCORDANCE WITH STD. PLAN 201.00 UNLESS OTHERWISE SPECIFIED. 4.BAFFLE WALL SHALL HAVE #4 BAR AT 12" SPACING EACH WAY. 5.PRECAST BAFFLE WALL SHALL BE KEYED AND GROUTED IN PLACE. 6.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. NOTES: FRAME AND ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 6" MIN.W WEIR SHAPE AS NEEDED FOR PERFORMANCE DESIGN WATER SURFACE (WS) SHEAR GATE WITH CONTROL ROD FOR DRAIN PER STD. PLAN 237.30 I.E. WEIR, INLET PIPE, AND DRAIN = CROWN OUTLET PIPE FLOW OUTLET PIPE FRAME ELEVATION PER PLANS12" MIN. UNDER PAVEMENT 2' MIN. 2' MIN. SECTION A SECTION B ISOMETRIC PLAN W LOCATE ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN SUMP IS FILLED WITH WATER SHEAR GATE. LOCATE HORIZONTAL FOR CLEARANCE WITH LADDER. ATTACH ROD TO SUPPORT BRACKET ON INSIDE OF ACCESS OPENING HANDHOLDS, STEPS OR LADDER (2 PLACES) A BSEE NOTE 6 (TYP.) 6" MIN., SEE NOTES 4 AND 5 FLOW CONTROL STRUCTURE - CONTROL WEIR STD. PLAN - 237.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT LEVEL LINE SEE NOTE 5 1.SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26-ZG-32a OR CAST IRON ASTM A48 CLASS 30B AS REQUIRED. 2.GATE SHALL BE 8 INCH DIA. UNLESS OTHERWISE SPECIFIED. 3.GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE), WELDING, OR OTHER SECURE MEANS. 4.LIFT ROD: AS SPECIFIED BY MFR. WITH HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD. 5.GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE. 6.NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. 7.MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT. 8.FLANGE MOUNTING BOLTS SHALL BE 3/8" DIA. STAINLESS STEEL. 9.ALTERNATE CLEANOUT/SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE AND HAVE A SIX BOLT, 10 3/8" BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION. LIFT HANDLE FRONT SIDE MAXIMUM OPENING OF GATE NOTES: (6) EVENLY SPACED HOLES ON 10 3/8" BOLT CIRCLE FOR BOLTING TO FLANGE CONNECTION HANDLE WITH LOCK PIN ADJUSTABLE LOCK HOOK WITH LOCK SCREW 1" ROD OR TUBING, VARIABLE LENGTH LIFT HANDLE SHALL BE ATTACHED PER MANUFACTURER'S RECOMMENDATIONSLEVEL LINETEE SECTION SHEAR GATE STD. PLAN - 237.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SECTION A PLAN INFLOW PIPE INFILTRATION POND SETTLING POND IF REQUIRED ACCESS ROAD OUTFLOW/OVERFLOW STRUCTURE EMERGENCY OVERFLOW SPILLWAY 5' MIN. EXISTING GROUND H 12'-15' IF H>6' 6' IF H<6' (TYP.) NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 3.ALL FACILITIES SHALL HAVE FENCES. FENCE SHALL BE PROVIDED AROUND FACILITY ALLOWING PROPER MAINTENANCE PER STD. PLAN 234.40. 4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. TRACT/EASEMENT LINES AS REQUIRED CONNECTING SPILLWAY A3H:1V (TYP.) KEY REQUIRED FOR BERM HEIGHT>4' TYPICAL INFILTRATION POND STD. PLAN - 238.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLAN INLET PIPE (FLOW THROUGH) OUTLET PIPE OPTIONAL PARALLEL TANK ACCESS RISERS, SEE NOTE 6 ACCESS RISERS PER STD. PLAN 235.10 ACCESS MANHOLE WITH 24" BOLT LOCKING RING AND COVER PER STD. PLANS 204.40 AND 204.50 CLEAN DRAIN ROCK (1-1/2" - 3") TO TOP OF TANK, 2' MIN., 5' MAX. BEYOND EDGES, SEE NOTE 4 SETTLING VAULT OR TYPE 2 CATCH BASIN (CB) IF REQUIRED SECTION A INFILTRATION TANK (SIZE AS REQUIRED) 1" HOLES AS REQUIRED, SEE NOTE 10 CLEAN DRAIN ROCK (1-1/2" - 3") TO TOP OF TANK, 2' MIN., 5' MAX. BEYOND EDGES, 1' MIN. BELOW BOTTOM, SEE NOTE 4 TYPE 2 CB OR SETTLING VAULT IF REQUIRED 2" MIN. DIA AIR VENT PIPE WELDED TO TANK (REQUIRED IF NO ACCESS RISER ON TANK) OVERFLOW RISER FOR INFILTRATION ONLY. FOR DETENTION/RETENTION SEE STD. PLAN 235.00 OVERFLOW STRUCTURE, 54" MIN. DIA TYPE 2 CB GEOTEXTILE (TOP ONLY), SEE NOTE 4 2' MAX. 50' MAX.100' MAX.50' MAX. 2' MIN.4' MIN. 36" MIN. DIA (TYP.) NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.MINIMUM TANK DIAMETER IS 36 INCHES. 3.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4.GEOTEXTILE FOR UNDERGROUND DRAINAGE, CLASS A, TO BE PLACED OVER CLEAN DRAIN ROCK, PER WSDOT STANDARD SPECIFICATIONS SECTION 9-33.2(1). 5.THE PROPOSED BOTTOM SHALL BE AT LEAST 3 FEET ABOVE THE SEASONAL HIGH WATER LEVEL AND HAVE AT LEAST 3 FEET OF PERMEABLE SOIL BENEATH THE BOTTOM. 6.ACCESS RISERS REQUIRED WITHIN 50 FEET FROM ANY LOCATION IN THE INFILTRATION TANK AND WITHIN 5 FEET OF EACH TERMINAL END. ANY LOCATION WITHIN THE INFILTRATION TANK SHALL HAVE A DIRECT LINE OF SIGHT FROM AN ACCESS POINT, UNOBSTRUCTED BY ANY RESTRICTIONS SUCH AS A WALL OR BAFFLE. 7.H-20 LIVE LOADS MUST BE ACCOMMODATED FOR TANKS LYING UNDER PARKING AREAS, ROADWAYS, AND ACCESS ROADS. 8.PIPE MATERIAL, JOINTS, AND PROTECTIVE TREATMENT FOR TANKS SHALL BE IN ACCORDANCE WITH SECTIONS 7-04 AND 9-05 OF THE WSDOT/APWA STANDARD SPECIFICATIONS. 9.ALL TANK ACCESS OPENINGS MUST BE READILY ACCESSIBLE BY MAINTENANCE VEHICLES. 10.THE NUMBER AND SPACING OF THE HOLES SHOULD BE SUFFICIENT TO ALLOW COMPLETE UTILIZATION OF THE AVAILABLE INFILTRATION CAPACITY OF THE SOILS WITH A SAFETY FACTOR OF 2.0 WITHOUT JEOPARDIZING THE STRUCTURAL INTEGRITY OF THE TANK. 11.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 12.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. A 2' MIN. SEE NOTE 11 (TYP.) 6" MIN. SEE NOTE 11 (TYP.) FINISH GRADE 6" 2' MIN. 36" MIN. 36" MIN. "FLOW-THROUGH" SYSTEM SHOWN SOLID. DESIGNS FOR "FLOW BACKUP" SYSTEM AND PARALLEL TANKS SHOWN DASHED CLOSED BOTTOM SAME SIZE AS INLET PIPE, 12" MIN. DIA. 5' MAX. TERMINAL END TYPICAL INFILTRATION TANK STD. PLAN - 238.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT PLAN INFLOW OIL/WATER SEPARATOR CHAMBER NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.GRAVITY DRAIN SHALL BE AT LEAST 8 INCH MINIMUM DIAMETER AND SHALL BE CONTROLLED BY A VALVE . USE OF A SHEAR GATE IS ALLOWED ONLY AT THE INLET OF A PIPE LOCATED WITHIN AN APPROVED STRUCTURE. 3.ACCESS TO EACH COMPARTMENT IS REQUIRED, ON EACH END, AND EVERY 50 FEET MINIMUM. 4.VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 5.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 6.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. HIGH FLOW BYPASS INLET PIPE (8" MIN.) ACCESS COVER (TYP.) WITH LADDER ACCESS TO VAULT. IF > 1,250SF, PROVIDE 5'x10' REMOVABLE PANEL OVER INLET/OUTLET PIPE OUTLET PIPE (8" MIN.) SHUT OFF VALVE WITH RISER & VALVE BOX 20' MAX. (RECOMMENDED) 6' MIN. W 5' MAX. TEE FOREBAY FLOW SPREADING BAFFLE (RECOMMENDED) SLUDGE RETAINING BAFFLE OIL RETAINING BAFFLE EXISTING GRADE TEE (8" MIN.) GRAVITY DRAIN REMOVABLE TEE (RECOMMENDED) H=7' MIN. 20' MAX. 2' MIN. D 3' MIN., 8' MAX.12" MIN. 2' MIN. 50% D MIN. 12" MIN.12" MIN. 6" MIN. 12" MIN.8' MIN.L/3 - L/2 (APPROX) L = 5W SECTION SEE NOTE 5 (TYP.) SEE NOTE 5 (TYP.) ACCESS MANHOLE WITH 24" BOLT LOCKING RING AND COVER PER STD. PLANS 204.40 AND 204.50 2' MIN. COVER SEE NOTE 5 (TYP.) SEE NOTE 5 (TYP.) LADDER (TYP.)12" MIN. VENTILATION PIPES AT CORNERS (TYP.) BAFFLE OIL/WATER SEPARATOR STD. PLAN - 240.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT PLAN WATER QUALITY WATER SURFACE SUBMERGED INLET PIPE AFTERBAYFOREBAY NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.GRAVITY DRAIN SHALL BE AT LEAST 8 INCH MINIMUM DIAMETER AND SHALL BE CONTROLLED BY A VALVE . USE OF A SHEAR GATE IS ALLOWED ONLY AT THE INLET OF A PIPE LOCATED WITHIN AN APPROVED STRUCTURE. 3.ACCESS TO EACH COMPARTMENT IS REQUIRED, ON EACH END, AND EVERY 50 FEET MINIMUM. 4.VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 5.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 6.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 20' MAX. (RECOMMENDED) 5' MAX. HIGH FLOW BYPASS LADDER (TYP.) ACCESS COVER OVER OUTLET ACCESS COVER OVER INLET 12" MIN. VENTILATION PIPES AT CORNERS (TYP.) COALESCING PLATE RACK ACCESS DOOR ALLOWING REMOVAL OF PLATE PACK OR PROVIDE FULL LENGTH REMOVABLE COVERS ACROSS ENTIRE CELL SHUT OFF VALVE W / RISER AND VALVE BOX SECTION 20' MAX. 7' MIN. L/3 MIN. (L/2 RECOMMENDED) L 8' MIN. (L/4 RECOMMENDED) D 18" MIN. 12" MIN. 12" MIN. 6" MIN. 12" MIN. 6" MIN. VARIES (CAN BE CONSTRUCTED ON GRADE WITHOUT RISERS) 8" TEE OIL RETAINING BAFFLE (50% D MIN.) COALESCING PLATE RACK GRAVITY DRAIN INLET WEIR-SOLIDS RETAINING BAFFLE OR WINDOW WALL INLET PIPE (8" MIN.)SEE NOTE 5 (TYP.) 2' MIN. COVER OUTLET PIPE (8" MIN.) SEE NOTE 5 (TYP.) SEE NOTE 5 (TYP.) SEE NOTE 5 (TYP.) COALESCING PLATE OIL / WATER SEPARATOR STD. PLAN - 240.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLAN INFLOW WATER QUALITY DESIGN WATER SURFACE ELEVATION TO WATER QUALITY FACILITY NOTES: INFLOW TO WATER QUALITY FACILITY TO BYPASS CONVEYANCE SYSTEM OR DETENTION PONDTYPE 2 CATCH BASIN REINFORCED BAFFLE WALL GROUTED TO M.H. STRUCTURE (BOTH ENDS) SECTION A ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 HANDHOLD AND STEPS OR LADDER ACCESS (PROVIDE LADDERS TO BOTH SIDES OF WALL IF WEIR >36" HIGH) 4" MIN. THICK REINFORCED CONCRETE BAFFLE WALL OR OTHER SUITABLE MATERIAL BYPASS PIPE 7' MIN. 4' MIN. OR PROVIDE SEPARATE ACCESS TO EITHER SIDE OF BAFFLE WALL 2' MIN. 1.THE WATER QUALITY DISCHARGE PIPE MAY REQUIRE AN ORIFICE PLATE TO BE INSTALLED ON THE OUTLET TO CONTROL THE HEIGHT OF THE DESIGN WATER SURFACE (WEIR HEIGHT). THE DESIGN WATER SURFACE SHOULD BE SET TO PROVIDE A MINIMUM HEADWATER/DIAMETER RATIO OF 2.0 ON THE OUTLET PIPE. A FLOW SPLITTER - OPTION A STD. PLAN - 241.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT PLAN NOTES: TO WATER QUALITY FACILITY SECTION A ROUND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 1.DIAMETER (D) OF STANDPIPE SHOULD BE LARGE ENOUGH TO MINIMIZE HEAD ABOVE WATER QUALITY DESIGN WATER SURFACE AND TO KEEP WATER QUALITY DESIGN FLOWS FROM INCREASING MORE THAN 10% DURING 100-YEAR FLOWS. INFLOW TO BYPASS CONVEYANCE SYSTEM OR DETENTION POND TYPE 2 CATCH BASIN, NO BASE CHANNEL REQUIRED 2D DIA OF STANDPIPE, SEE NOTE 1 (2 x DIA OF OUTLET PIPE RECOMMENDED AS STARTING POINT) INFLOW TO WATER QUALITY FACILITY TOP OF RISER AT DESIGN WATER SURFACE ELEVATION "TEE" SECTION WITH CLEAN OUT (OR REMOVABLE BEND-DOWN ELBOW) ORIFICE SIZED TO PASS WATER QUALITY DESIGN FLOW LADDER (TYP.) TOP OF PIPE AT WATER QUALITY DESIGN WATER SURFACE ELEVATION AND HEAD LOSSES IN OUTLET PIPE SOLID BOTTOM (PROVIDE MAINTENANCE ACCESS) 7' MIN. 2' MIN. 6" 6" BAFFLE TO CONTROL FLOATABLES BAFFLE TO CONTROL FLOATABLES OR PROVIDE SPILL CONTROL UPSTREAM A D FLOW SPLITTER - OPTION B STD. PLAN - 241.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT ALTERNATIVE DESIGN CATCH BASIN RECOMMENDED FOR HIGHER FLOW SITUATIONS (GENERALLY FOR INFLOW VELOCITIES OF 5 FPS OR GREATER FOR 100 YEAR STORM). *SAND FILTER MAY USE OTHER SPREADING OPTIONS. EXAMPLE OF ANCHORED PLATE USED WITH A SAND FILTER* (MAY ALSO BE USED WITH OTHER WATER QUALITY FACILITIES). PLAN SECTION A SAND BED NOTES: 1.FLOW SPREADER PLATES MAY BE MADE OF EITHER METAL, FIBERGLASS REINFORCED PLASTIC, RECYCLED PLASTIC, OR OTHER DURABLE MATERIAL. WOOD IS NOT ALLOWED. 2.ANCHOR POST SHALL BE 4-INCH SQUARE CONCRETE, TUBULAR STAINLESS STEEL, OR OTHER MATERIAL RESISTANT TO DECAY. WOOD IS NOT ALLOWED. 3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. INLET PIPE V-NOTCHED OR LEVEL PLATE SPREADER EXTEND INTO SLOPE TO PROTECT FROM THE 100-YEAR FLOW OR THE HIGHEST FLOW ENTERING WATER QUALITY FACILITY RIPRAP AS SHOWN ON PLANS (TYP.) POND SIDE SLOPES (TYP.) SAND LAYER GRAVEL LAYER EXISTING GRADE 2" MIN. 8" MIN. 2' MIN.2' MIN. EMBEDDED INTO EXISTING GROUND INLET PIPE2" MIN, EDGE OF SAND ANCHOR POSTS SPACED 6' O.C. OR AT EACH END IF WIDTH < 6'A2" MIN. THICK LEVEL SPREADER PLATE BOLTED TO ANCHOR POST RIPRAP AS SHOWN ON PLANS (TYP.) FLOW SPREADER - OPTION A ANCHORED PLATE STD. PLAN - 242.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.EXTEND SIDES INTO SLOPE. HEIGHT OF SIDE WALL AND WING WALLS MUST BE SUFFICIENT TO HANDLE THE 100-YEAR FLOW OR THE HIGHEST FLOW ENTERING THE FACILITY. 2.CONCRETE FOR SUMP BOX MAY BE EITHER CAST-IN-PLACE OR PRE-CAST, BUT THE BOTTOM OF THE SUMP SHALL BE REINFORCED WITH WIRE MESH FOR CAST-IN-PLACE SUMPS. 3.SUMP BOXES SHALL BE PLACED OVER BASES THAT CONSIST OF 4 INCHES OF CRUSHED ROCK, 5/8-INCH MINUS TO ENSURE THAT THE SUMP REMAINS LEVEL. 4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. EXAMPLE OF A CONCRETE SUMP FLOW SPREADER USED WITH A BIOFILTRATION SWALE (MAY BE USED WITH OTHER WATER QUALITY FACILITIES). PLAN SWALE BOTTOM SIDE WITH WING WALLS (TYP.), SEE NOTE 1 RIPRAP AS SHOWN ON PLANS (TYP.) INLET PIPE 24" MIN. 8" MIN. 2" MIN. CLEARANCE WING WALL OUTLINE CONCRETE SUMP (4" WALL THICKNESS) SECTION A 2" MIN. SECTION B A BCONCRETE SUMP INLET PIPE RIPRAP AS SHOWN ON PLANS (TYP.) RIPRAP AS SHOWN ON PLANS (TYP.) FLOW SPREADER - OPTION B CONCRETE SUMP BOX STD. PLAN - 242.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT OUTLET PLAN TYPICAL SWALE SECTION UNDERDRAIN SECTION NOTES: 1.LONGITUDINAL SLOPE, 1% TO 6%. IF THE LONGITUDINAL SLOPE IS LESS THAN 1.5%, UNDERDRAINS MUST BE PROVIDED OR THE SWALE MUST BE DESIGNED AS A WET BIOSWALE. IF THE LONGITUDINAL SLOPE EXCEEDS 6 PERCENT, CHECK DAMS WITH VERTICAL DROPS OF 12 INCHES OR LESS SHALL BE PROVIDED. 2.UNDERDRAIN MUST INFILTRATE OR DRAIN FREELY TO AN ACCEPTABLE DISCHARGE POINT. UNDERDRAIN TO BE PVC PERFORATED PIPE, SDR 35 PER ASTM D3034. 3.THE DIVIDER SHALL EXTEND FROM THE FLOW SPREADER AT THE INLET FOR AT LEAST THREE-QUARTERS OF THE SWALE LENGTH. THE DIVIDER SHALL BE CONSTRUCTED OF A FIRM MATERIAL THAT WILL RESIST WEATHERING AND NOT ERODE, SUCH AS CONCRETE, COMPACTED SOIL SEEDED WITH GRASS, UNTREATED HEARTWOOD CEDAR, OR UNTREATED WHOLE DE-BARKED CEDAR LOGS. 4.ACCESS ROAD SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 5.IF NATIVE SOIL HAS LESS THAN 1% ORGANIC CONTENT, 2" COMPOST PER STD. PLAN 262.60 SHALL BE TILLED INTO 6" NATIVE SOIL 6.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. FLOW SPREADER PER STD. PLAN 242.00 OR 242.10 MID SWALE FLOW SPREADER (RECOMMENDED) PER STD. PLAN 242.00 OR 242.10 BIOFILTRATION SWALE BOTTOM (MIN SWALE LENGTH = 100 FT) ACCESS ROAD, SEE NOTE 4 AND TABLE 6.3.1.B BOTTOM WIDTH (B) 2' MIN. 16' + DIVIDER WIDTH MAX. WATER QUALITY DESIGN DEPTH (Y), 4" MAX. (2" FOR FREQUENTLY MOWED AREAS) COMPOST AMENDED SOIL, SEE NOTE 5 SWALE DIVIDER FOR WIDTH > 10', HEIGHT = Y+1", SEE NOTE 3 SWALE BOTTOM FILTER FABRIC 6" MIN. DIA. PERFORATED UNDERDRAIN PIPE CENTERED BENEATH SWALE, SEE NOTE 2 5/8" CLEAN DRAIN ROCK OR GRAVEL BACKFILL FOR DRAINS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(4) FILTER FABRIC, WRAP TOP, SIDES, AND BOTTOM PER WSDOT STD. SPEC. 9-33.2(1) UNDISTURBED NATIVE SOIL 6" MIN. OVER PIPE UNDERDRAIN SECTION FOR SLOPES <1.5% MIN. 6" DIA. PERFORATED UNDERDRAIN PIPE CENTERED BENEATH SWALE, SEE NOTE 2 UNDISTURBED NATIVE SOIL 3 1 3 1 5/8" CLEAN DRAIN ROCK OR GRAVEL BACKFILL FOR DRAINS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(4) COMPOST AMENDED SOIL, SEE NOTE 5 COMPOST AMENDED SOIL, SEE NOTE 5 TABLE 6.3.1.B - REQUIREMENTS FOR BIOSWALE ACCESS ROAD SWALE BOTTOM AREA¹: L x W (SF)ACCESS ROAD LENGTH² 200-1000 1/2 SWALE LENGTH L 1000-1600 2/3 SWALE LENGTH L OVER 1600 ENTIRE SWALE LENGTH L ¹ THE SWALE AREA USED FOR COMPUTING ACCESS ROAD LENGTH MAY BE THE BOTTOM AREA ² CITY STREETS AND PAVED PARKING AREAS ADJACENT TO THE TOP OF SLOPE MAY BE COUNTED AS ACCESS BIOFILTRATION SWALE SCHEMATIC, CROSS SECTION, AND UNDERDRAIN DETAIL STD. PLAN - 243.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT PLANTINGS REQUIRED ON CUT SLOPES FOR SENSITIVE LAKE PROTECTION FACILITIES ACCESS ROAD TO INLET STRUCTURE ACCESS ROAD TO OUTLET STRUCTURE NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.SEE STANDARD PLAN 249.10 FOR TYPICAL WETPOND CROSS SECTIONS. 3.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 4.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 5.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY. 6.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 6.4.1.2 OF THE RENTON SWDM. 7.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STD. PLAN 234.40. 8.WETPONDS WITH WETPOOL VOLUMES LESS THAN OR EQUAL TO 4,000 CUBIC FEET MAY BE SINGLE-CELLED (I.E. NO BAFFLE OR BERM IS REQUIRED). 9.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. INLET PIPE & CATCH BASIN PER DETENTION FACILITY REQUIREMENTS TOP OF BERM OR BAFFLE TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS). EXTEND BERM OR BAFFLE ACROSS ENTIRE WETPOOL WIDTH FIRST WETPOOL CELL 25% TO 35% OF WETPOOL VOLUME, EXCLUDING ACCESS RAMP BERM, TOP WIDTH 5' MIN. IF EARTHEN SECOND WETPOOL CELL WQ DESIGN WS OVERFLOW WS EMERGENCY OVERFLOW WS EMERGENCY SPILLWAY PER DETENTION FACILITY REQUIREMENTS MANHOLE OR TYPE 2 CATCH BASIN AND OUTLET PIPE SIZED TO PASS PEAK FLOW PER CONVEYANCE REQUIREMENTS OUTLET EROSION CONTROL & ENERGY DISSIPATION PER DETENTION FACILITY REQUIREMENTS ACCESS RAMP TO BOTTOM OF FIRST WETPOOL CELL QUARRY SPALL PAD 3H:1V MAX. SEE NOTE 4 3H:1V MAX. SEE NOTE 4 OUTLET PIPE SEE NOTE 9 (TYP.) TYPICAL WETPOND STD. PLAN - 249.00A249.10PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)B249.10DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SCALE: CROSS-SECTION A 249.00NTS XXEMERGENCY OVERFLOW WS OVERFLOW WS WQ DESIGN WS INLET EMERGENCY OVERFLOW WS OVERFLOW WS WQ DESIGN WS NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 3.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 4.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY. 5.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 6.4.1.2 OF THE RENTON SWDM. 6.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STANDARD PLAN 234.40. 7.WETPONDS WITH WETPOOL VOLUMES LESS THAN OR EQUAL TO 4,000 CUBIC FEET MAY BE SINGLE-CELLED (I.E. NO BAFFLE OR BERM IS REQUIRED). 8.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 9.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. SLOPE VEGETATION PER DETENTION FACILITY REQUIREMENTS EMERGENT VEGETATION REQUIRED FOR WETPOOL DEPTHS 3' OR LESS KEYED BERM IF TOP OF BERM IS SUBMERGED 1' BELOW WQ DESIGN WS, BERM SIDE SLOPES MAY BE 2H:1V, OTHERWISE SIDE SLOPES MUST BE 3H:1V INLET EROSION CONTROL/SLOPE PROTECTION PER DETENTION FACILITY REQUIREMENTS 2' MIN. SEDIMENT STORAGE DEPTH, 12" MIN. FIRST CELL DEPTH 4' MIN. TO 8' MAX. WETPOOL FLOW LENGTH = 3 MIN. x WIDTH WETPOOL DEPTH 8' MAX. RECIRCULATION RECOMMENDED FOR DEPTH > 6' SEE STD. PLAN 234.40 FOR FENCE REQUIREMENTS ACCESS ROAD CAPACITY OF OUTLET SYSTEM SIZED TO PASS PEAK FLOW FOR CONVEYANCE REQUIREMENTS EXTERIOR BERMS DESIGNED PER DAM SAFETY REQUIREMENTS IF APPLICABLE MANHOLE OR TYPE 2 CATCH BASIN VALVE (MAY BE LOCATED INSIDE MH OR OUTSIDE WITH APPROVED OPERATIONAL ACCESS) GRAVITY DRAIN (IF GRADE ALLOWS) 8" MIN. DIAMETER INVERT 6" MIN. BELOW TOP OF INTERNAL BERM. LOWER PLACEMENT IS DESIRABLE 12" MIN 18" MIN. SCALE: CROSS-SECTION B 249.00NTS 6" SEDIMENT STORAGE COMPACT TO 95% OF MAXIMUM DRY DENSITY OUTLET PIPE INVERT AT WETPOOL WS ELEVATION SEE NOTE 8 (TYP.) TOP OF BERM OR BAFFLE TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) INLET SUBMERGED 12" MIN. TYPICAL WETPOND SECTIONS STD. PLAN - 249.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) 3 1 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SECTION B SECTION A PLAN VIEW ACCESS COVER OR DOORS REQUIRED. WQ DESIGN WS INLET FIRST CELL SIZED FOR 25% TO 35% OF WETPOOL VOLUME WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.THE VAULT SHALL BE SEPARATED INTO TWO CELLS BY A WALL OR A REMOVABLE BAFFLE. IF A WALL OR NON REMOVABLE BAFFLE IS USED, A 5-FOOT x 10-FOOT REMOVABLE MAINTENANCE ACCESS MUST BE PROVIDED FOR BOTH CELLS. 3.FOR VAULTS UNDER ROADWAYS, THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY, MULTIPLE STANDARD LOCKING MANHOLE COVERS MAY BE PROVIDED. SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER, TO FACILITATE REMOVAL OF SEDIMENT. LADDERS AND HAND-HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE. 4.MINIMUM DIAMETER FOR ALL ACCESS OPENINGS (RISERS), EXCEPT THOSE COVERED BY REMOVABLE PANELS, IS 36 INCHES. 5.REMOVABLE PANEL SHALL BE AT GRADE, HAVE STAINLESS STEEL LIFTING EYES, AND WEIGH NO MORE THAN 5 TONS PER PANEL. 6.VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 7.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 8.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 5'x10' GRATE, GRATED ACCESS DOOR, OR LOCKING ACCESS PANEL OVER SECOND CELL. FOR VAULTS WHERE SURFACE AREA OF SECOND CELL IS GREATER THAN 1,250 SQUARE FEET, 4% OF THE TOTAL SURFACE AREA MUST BE GRATED AND A 5'x10' REMOVABLE LOCKING PANEL SHALL BE PROVIDED LADDER "V" SHAPED BOTTOM REMOVABLE BAFFLE OR WALL, SEE NOTE 2 WETPOOL WIDTH WETPOOL LENGTH 12" MIN. 12" MIN. REMOVABLE BAFFLE LADDER 12" 2' MIN. WETPOOL DEPTH 8' MAX. SIZE TO CONVEY 100-YEAR DESIGN FLOW WITHOUT OVERTOPPING, 6" MIN. 4" MIN. 16" MAX. FRAME AND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 OUTLET WITH CAPACITY TO CONVEY 100-YEAR DESIGN FLOW WITHOUT OVERTOPPING GRAVITY DRAIN (IF GRADE ALLOWS). PLACE AS LOW AS GRADE ALLOWS BUT MUST BE 6" MIN. ABOVE THE BASE ELEVATION OF VAULT WALLS OR ABOVE SEDIMENT STORAGE AREA 3' MIN. AVERAGE SEDIMENT STORAGE 12" MIN. (FIRST CELL) BOTTOM SLOPE 0.5%-2% TOWARD INLET END BOTTOM SLOPE 0.5%-2% TOWARD OUTLET END OF SECOND CELL (RECOMMENDED) ACCESS DOORS OR REMOVABLE PANEL, SEE NOTE 5 AVERAGE 12" SEDIMENT STORAGE (FIRST CELL) 4' MIN. 7' MIN. NOTES: A BINLET OUTLET 8" MIN. GRAVITY DRAIN SEE NOTE 7 (TYP.) VALVE SEE NOTE 7 (TYP.) SHEAR GATE 12" MIN. VENTILATION PIPES AT CORNERS (TYP.), SEE NOTE 6 18" MAX. FROM CENTER OF FRAME TO STRUCTURE WALL FOR STEP ACCESS 6" MAX. FROM EDGE OF OPENING TO STRUCTURE WALL FOR STEP ACCESS 12" MIN. 5% MIN. (TY P . ) WETVAULT STD. PLAN - 249.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT PLANT WITH WETLAND PLANTS PER TABLE 6.4.1.A OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL ACCESS ROAD ACCESS ROAD SPILLWAY WETLAND CELLFIRST CELL (FOREBAY) INFLOW INLET WITH SPILL CONTROL WQ DESIGN WS 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 3.ALL FACILITIES SHALL BE FENCED. FENCE SHALL BE PROVIDED AROUND FACILITY ALLOWING PROPER MAINTENANCE PER STANDARD PLANS UNLESS OTHERWISE SPECIFIED. FENCE TO BE PROVIDED IN ACCORDANCE WITH STD. PLAN 234.40. 4.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 5.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. PLAN VIEW INLET SUBMERGED 12" MIN. INLET EROSION CONTROL/SLOPE PROTECTION PER DETENTION FACILITY REQUIREMENTS MANHOLE OR TYPE 2 CATCH BASIN IF REQUIRED, PLACE LINER IN SECOND CELL TO HOLD WATER 2' MIN. FIRST CELL DEPTH 4' MIN. TO 8' MAX. TOP OF BERM TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) SEDIMENT STORAGE DEPTH = 12" MIN. 2.5' MAX. SECTION VIEW NOTES: QUARRY SPALL PAD SEE NOTE 4 (TYP.) OUTLET PIPE SIZED TO PASS PEAK FLOW FOR CONVEYANCE REQUIREMENTS IF TOP OF BERM IS SUBMERGED 1' BELOW WQ DESIGN WS, BERM SIDE SLOPES MAY BE 2H:1V, OTHERWISE SIDE SLOPES MUST BE 3H:1V PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STORMWATER WETLAND OPTION A STD. PLAN - 249.30 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT ACCESS ROAD TO INLET STRUCTURE FIRST WETPOOL CELL 25% TO 35% OF WETPOOL VOLUME, EXCLUDING ACCESS RAMP SECOND WETPOOL CELL NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.SEE STANDARD PLAN 252.10 FOR TYPICAL COMBINED DETENTION AND WETPOND CROSS SECTIONS. 3.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 4.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 5.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY OR ZONE 1 OF THE APA. 6.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 6.4.1.2 OF THE RENTON SWDM. 7.ALL FACILITIES SHALL BE FENCED. FENCE SHALL BE PROVIDED IN ACCORDANCE WITH STD. PLAN 234.40. 8.LANDSCAPING, TREES, AND POND GEOMETRY STANDARDS ARE SPECIFIED IN STD. PLAN 234.40. 9.COMBINED DETENTION AND WETPONDS WITH WETPOOL VOLUMES LESS THAN OR EQUAL TO 4,000 CUBIC FEET MAY BE SINGLE-CELLED (I.E. NO BAFFLE OR BERM IS REQUIRED). 10.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 11.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. INLET PIPE & CATCH BASIN PER WETPOND FACILITY REQUIREMENTS ACCESS RAMP TO BOTTOM OF FIRST WETPOOL CELL BERM TOP WIDTH 5' MIN. (IF EARTHEN) TOP OF BERM OR BAFFLE TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS). EXTEND BERM OR BAFFLE ACROSS ENTIRE WETPOOL WIDTH EMERGENCY OVERFLOW WS OVERFLOW WS DETENTION WS WQ DESIGN WS OUTLET FLOW CONTROL STRUCTURE PER STD. PLANS 237.00-237.20 AND OUTLET PIPE SIZED PER DETENTION FACILITY REQUIREMENTS OUTLET EROSION CONTROL & ENERGY DISSIPATION PER DETENTION FACILITY REQUIREMENTS TRACT LINES AS REQUIRED 5' SETBACK, MIN. WETPOOL WIDTH EMERGENCY SPILLWAY PLANTINGS REQUIRED ON CUT SLOPES FOR SENSITIVE LAKE PROTECTION FACILITIES QUARRY SPALL PAD 3H:1V MAX. SEE NOTE 4 3H:1V MAX. SEE NOTE 4 OUTLET PIPE SEE NOTE 10 (TYP.) COMBINED DETENTION AND WETPOND STD. PLAN - 252.00A252.10PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)B252.10DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SCALE: CROSS-SECTION A 252.00NTS XXEMERGENCY OVERFLOW WS DETENTION OVERFLOW WS DETENTION DESIGN WS EMERGENCY OVERFLOW WS DETENTION OVERFLOW WS DETENTION DESIGN WS WQ DESIGN WS WQ DESIGN WS NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 3.SIDE SLOPES (INTERIOR AND EXTERIOR) SHALL NOT BE STEEPER THAN THREE (3) FEET HORIZONTAL TO ONE (1) FOOT VERTICAL. 4.OPEN PONDS SHALL NOT BE LOCATED IN DEDICATED PUBLIC RIGHT-OF-WAY OR ZONE 1 OF THE APA. 5.EXPOSED EARTH ON THE POND BOTTOM AND INTERIOR SIDE SLOPES SHALL BE SODDED OR SEEDED WITH AN APPROPRIATE SEED MIXTURE PER SECTION 5.1.1.1 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). ALL REMAINING AREAS OF THE TRACT MUST EITHER BE PLANTED WITH GRASS, OR BE LANDSCAPED IN ACCORDANCE WITH LANDSCAPING REQUIREMENTS INCLUDED IN SECTION 6.4.1.2 OF THE RENTON SWDM. 6.ALL FACILITIES SHALL BE FENCED IN ACCORDANCE WITH STD. PLAN 234.40. 7.LANDSCAPING, TREES, POND GEOMETRY AND FENCING STANDARDS ARE SPECIFIED IN STD. PLAN 234.40. 8.COMBINED DETENTION AND WETPONDS WITH WETPOOL VOLUMES LESS THAN OR EQUAL TO 4,000 CUBIC FEET MAY BE SINGLE-CELLED (I.E. NO BAFFLE OR BERM IS REQUIRED). 9.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. GRAVITY DRAIN (IF GRADE ALLOWS) 8" MIN. DIAMETER 3 1 3 1 ACCESS ROAD SLOPE VEGETATION PER DETENTION FACILITY REQUIREMENTS EMERGENT VEGETATION REQUIRED FOR WETPOOL DEPTHS 3' OR LESS. TOP OF BERM OR BAFFLE TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) INLET EROSION CONTROL/SLOPE PROTECTION PER DETENTION FACILITY REQUIREMENTS INLET SUBMERGED 12" MIN. WETPOOL FLOW LENGTH = 3 x WIDTH MIN. 2' MIN. FIRST CELL DEPTH 4' MIN. TO 8' MAX. SEDIMENT STORAGE DEPTH, 12" MIN. KEYED BERM WETPOOL DEPTH 8' MAX. RECIRCULATION RECOMMENDED FOR DEPTH > 6' DETENTION PER DETENTION FACILITY REQUIREMENTS OUTLET PIPE INVERT OUT AT WETPOOL WS ELEVATION ACCESS ROAD CAPACITY OF OUTLET SYSTEM PER DETENTION FACILITY REQUIREMENTS EXTERIOR BERMS DESIGNED PER DAM SAFETY REQUIREMENTS IF APPLICABLE OUTLET FLOW CONTROL STRUCTURE PER STD. PLANS 237.00-237.20 VALVE INVERT 6" MIN. BELOW TOP OF INTERNAL BERM. LOWER PLACEMENT IS DESIRABLE 12" 18" MIN. SCALE: CROSS-SECTION B 252.00NTS SEE STD. PLAN 234.40 FOR FENCE REQUIREMENTS 6" SEDIMENT STORAGE SEE NOTE 9 (TYP.) COMPACT TO 95% OF MAXIMUM DRY DENSITY IF TOP OF BERM IS SUBMERGED 1' BELOW WQ DESIGN WS, BERM SIDE SLOPES MAY BE 2H:1V, OTHERWISE SIDE SLOPES MUST BE 3H:1V SEE NOTE 9 (TYP.) COMBINED DETENTION AND WETPOND SECTIONS STD. PLAN - 252.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT DETENTION DESIGN WS WQ DESIGN WS ACCESS ROAD SLOPE VEGETATION PER DETENTION FACILITY REQUIREMENTS INLET EROSION CONTROL/SLOPE PROTECTION PER DETENTION FACILITY REQUIREMENTS INLET SUBMERGED 12" MIN. 2' MIN. FIRST CELL DEPTH 4' MIN. TO 8' MAX. SEDIMENT STORAGE DEPTH, 12" MIN. IF REQUIRED, PLACE LINER IN SECOND CELL TO HOLD WATER FLOW CONTROL OUTLET STRUCTURE PER STD. PLANS 237.00 - 237.20 2'-6" MAX. DETENTION PER DETENTION FACILITY REQUIREMENTS NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.ACCESS ROAD AND RAMP SHALL MEET REQUIREMENTS IN STD. PLAN 234.50. 3.ALL FACILITIES SHALL BE FENCED. FENCE SHALL BE PROVIDED IN ACCORDANCE WITH STD. PLAN 234.40. 4.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 5.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 3 1 SEE NOTE 4 (TYP.) PLANT WITH WETLAND PLANTS PER TABLE 6.4.1.A OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL ACCESS ROAD ACCESS ROAD SPILLWAY WETLAND CELLFIRST CELL (FOREBAY) INFLOW PLAN VIEW QUARRY SPALL PAD SECTION VIEW IF TOP OF BERM IS SUBMERGED 1' BELOW WQ DESIGN WS, BERM SIDE SLOPES MAY BE 2H:1V, OTHERWISE SIDE SLOPES MUST BE 3H:1V TOP OF BERM TO BE LEVEL AND AT OR 1' BELOW WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) OUTLET PIPE SIZED PER DETENTION FACILITY REQUIREMENTS COMBINED DETENTION AND STORMWATER WETLAND STD. PLAN - 253.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SECTION B SECTION A PLAN VIEW ACCESS COVER OR DOORS REQUIRED. WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) INLET FIRST CELL SIZED FOR 25% TO 35% OF WETPOOL VOLUME WATER QUALITY (WQ) DESIGN WATER SURFACE (WS) 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.THE VAULT SHALL BE SEPARATED INTO TWO CELLS BY A WALL OR A REMOVABLE BAFFLE. IF A WALL OR NON REMOVABLE BAFFLE IS USED, A 5-FOOT x 10-FOOT REMOVABLE MAINTENANCE ACCESS MUST BE PROVIDED FOR BOTH CELLS. 3.FOR VAULTS UNDER ROADWAYS, THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY, MULTIPLE STANDARD LOCKING MANHOLE COVERS MAY BE PROVIDED. SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER, TO FACILITATE REMOVAL OF SEDIMENT. LADDERS AND HAND-HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE. 4.MINIMUM DIAMETER FOR ALL ACCESS OPENINGS (RISERS), EXCEPT THOSE COVERED BY REMOVABLE PANELS, IS 36 INCHES. 5.REMOVABLE PANEL SHALL BE AT GRADE, HAVE STAINLESS STEEL LIFTING EYES, AND WEIGH NO MORE THAN 5 TONS PER PANEL. 6.VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 7.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 8.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 5'x10' GRATE, GRATED ACCESS DOOR, OR LOCKING ACCESS PANEL OVER SECOND CELL. FOR VAULTS WHERE SURFACE AREA OF SECOND CELL IS GREATER THAN 1,250 SQUARE FEET, 4% OF THE TOTAL SURFACE AREA MUST BE GRATED AND A 5'x10' REMOVABLE LOCKING PANEL SHALL BE PROVIDED "V" SHAPED BOTTOM REMOVABLE BAFFLE OR WALL, SEE NOTE 2 WETPOOL WIDTH WETPOOL LENGTH 12" MIN. 12" MIN. REMOVABLE BAFFLE LADDER 2' MIN. 2' MIN. WETPOOL DEPTH 8' MAX. SIZE TO CONVEY 100-YEAR DESIGN FLOW WITHOUT OVERTOPPING, 6" MIN. 4" MIN. 16" MAX. FRAME AND SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 OUTLET WITH CAPACITY TO CONVEY 100-YEAR DESIGN FLOW WITHOUT OVERTOPPING GRAVITY DRAIN (IF GRADE ALLOWS). PLACE AS LOW AS GRADE ALLOWS BUT MUST BE 6" MIN. ABOVE THE BASE ELEVATION OF VAULT WALLS OR ABOVE SEDIMENT STORAGE AREA 3' MIN. AVERAGE SEDIMENT STORAGE 12" MIN. (FIRST CELL) BOTTOM SLOPE 0.5%-2% TOWARD INLET END BOTTOM SLOPE 0.5%-2% TOWARD OUTLET END OF SECOND CELL (RECOMMENDED) ACCESS DOORS OR REMOVABLE PANEL, SEE NOTE 5 AVERAGE 12" SEDIMENT STORAGE (FIRST CELL) 4' MIN. 7' MIN. NOTES: A BINLET OUTLET 8" MIN. GRAVITY DRAIN SEE NOTE 7 (TYP.) VALVE SEE NOTE 7 (TYP.) 12" MIN. VENTILATION PIPES AT CORNERS (TYP.), SEE NOTE 6 18" MAX. FROM CENTER OF FRAME TO STRUCTURE WALL FOR STEP ACCESS 6" MAX. FROM EDGE OF OPENING TO STRUCTURE WALL FOR STEP ACCESS 12" MIN. 5% MIN. (TY P . ) LADDER 2' MIN. FLOW RESTRICTOR COMBINED DETENTION AND WETVAULT STD. PLAN - 254.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: E212B987-C626-4330-A5D4-D055A0107AF9 10/19/2022 | 2:52 PM PDT DOWNSPOUT BUILDING ROOF (CONTRIBUTING IMPERVIOUS AREA SEE NOTE 4) PONDING EXTENTS GUTTER BIRD CAGE OVERFLOW ROCK OR VEGETATION LINED DITCH, OR PIPED CONNECTION, SEE NOTE 2 TOP OF SLOPE BOTTOM OF SLOPE (SHAPE CAN VARY TO FIT SITE, MINIMUM WIDTH = 18") RIGHT-OF-WAY (SIDEWALK OR ALLEY)PARCEL BOUNDARY5' MIN., SEE NOTE 1 5' MIN., SEE NOTE 1 GENERAL NOTES: 1.MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 265.00, 265.10, AND 265.20, AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. PIPED CONNECTION TO STORM DRAIN SYSTEM, SEE NOTE 2 DRIVEWAY (CONTRIBUTING IMPERVIOUS AREA SEE NOTE 4) SEE NOTE 3 ROCK SPLASH PAD PER STD. PLAN 260.10 DISPERSION TRENCH (TYP.), SEE STD. PLAN 260.10 TOP OF PONDING (USE AREA FOR SIZING, SEE NOTE 4) OPTIONAL COMPACTED EARTH BERM, 2' MIN. TOP WIDTH 2.5H:1V (OR FLATTER) A 260.10 NOTES: 1.TOP OF RAIN GARDEN SHALL BE 5 FEET MIN. FROM BUILDINGS WITHOUT BASEMENT AND 10 FEET MIN. FROM BUILDINGS WITH BASEMENTS. 2.SLOPE PIPED CONNECTION AT 2% (PREFERRED), 1% MIN. USE 6" MIN. ASTM D1785 SCH 40 PVC. CONNECTIONS TO STORM DRAIN SYSTEM REQUIRE CITY INSPECTION. 3.SHEET FLOW INTO RAIN GARDEN MAY BE KEPT WIDELY DISTRIBUTED OVER A STABILIZED SURFACE (PAVEMENT, PEA GRAVEL, GRASS). IF CONCENTRATED, PROVIDE A SWALE WITH DECORATIVE ROCK AND VEGETATION TO PREVENT EROSION. 4.RAIN GARDEN SIZE AT TOP OF PONDING (OVERFLOW ELEVATION) TO BE AT LEAST 5% OF CONTRIBUTING HARD SURFACE AREA. IF LAWN/LANDSCAPE AREA ALSO DRAINS TO RAIN GARDEN, INCREASE SIZE BY 2% OF LAWN/LANDSCAPE AREA. MAXIMUM CONTRIBUTING AREA SHALL BE 5,000 SF. 4' MIN. 6" MIN. FREEBOARD OPTIONAL SURFACE OVERFLOW WITH CITY APPROVAL RAIN GARDEN PLAN STD. PLAN - 260.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLANTING NOTES: 1.REFER TO THE RAIN GARDEN HANDBOOK FOR WESTERN WASHINGTON FOR GUIDANCE ON PLANT SELECTION SITING AND SPACING BY ZONE. 2.PLANTS MUST BE PERENNIAL AND ADAPTED TO THE CONDITIONS ENCOUNTERED IN ITS ZONE IN THE RAIN GARDEN. SEE PLANTING ZONE TABLE. 3.EVERGREEN AND DECIDUOUS VEGETATION MAY BE USED BUT THE MAJORITY OF MATERIAL MUST PROVIDE A SIGNIFICANT ABOVE GROUND PRESENCE YEAR ROUND. 4.PLANTING DESIGN SHOULD MINIMIZE COMPACTION OF SOIL THROUGH PLANNED MAINTENANCE ACCESS. ANNUAL PLANTS REQUIRING SOIL DISTURBANCE FOR HARVESTING (E.G., CARROTS) OR ANNUAL REPLANTING ARE NOT PERMITTED. SCALE: SECTION - RAIN GARDEN A 260.00NTS EXISTING GROUND PIPED CONNECTION (OPTIONAL) 2" MIN. WASHED ROUND ROCK. EXTEND TO 12" BEYOND BOTTOM OF RAIN GARDEN MIN. EXCAVATION EXTENT COMPOST AMENDED SOILS PER STD. PLAN 264.00 OR BIORETENTION SOIL MIX PER STD. PLAN 262.60 MULCH 3" DEPTH, SEE NOTE 2 2.5 MIN. 1 2.5 MIN. 1 12" MIN. 6" PONDING 6" MIN. FREEBOARD 1% MIN., 4% MAX. SLOPE 6" MIN.NON-WOVEN GEOTEXTILE FOR SEPARATION PER WSDOT SPECIFICATIONS GEOTEXTILE FOR SEPARATION SECTION 9-33.2(1) TABLE 3 3/4" - 1-1/2" WASHED DRAIN ROCK 6" MIN. 1" 4' MIN. DISPERSION TRENCH (TYP.) BOTTOM WIDTH 18" MIN. 3 2 1 2 3 PLANTING ZONES, SEE PLANTING NOTES AND PLANTING ZONES TABLE NOTES: 1.RAISED BERM SHALL BE FIRM, UNDISTURBED, NON-YIELDING NATIVE SOIL OR DISTURBED SITE SOILS COMPACTED WITH 12 POUND HAND TAMPER IN 3-INCH LIFTS. IF SITE SOILS ARE SANDY, CONSIDER IMPORTING DENSER, NON-PERMISSIVE SOILS FOR RAISED BERM. TOP WIDTH SHALL BE 6-INCHES MIN. 2.WOODY MULCH PREFERRED, ROCK MULCH OR BARK CHIP MULCH NOT PERMITTED. SEE STD. PLAN 262.60 FOR ARBORIST WOOD CHIP MULCH. 3.OVERFLOW TO BE PIPED TO STORM DRAIN SYSTEM PER STD. PLAN 260.00 UNLESS SURFACE OVERFLOW CAN BE DIRECTED TO A SUITABLE LOCATION AS APPROVED BY THE CITY. TABLE: PLANTING ZONES ZONE PLANT TYPE LOCATION 1 EMERGENTS, PERENNIALS & LOW SHRUBS (PLANTS THAT CAN TOLERATE STANDING WATER)FACILITY BOTTOM 2 EMERGENTS, PERENNIALS & LOW SHRUBS (PLANTS THAT CAN TOLERATE OCCASIONAL STANDING WATER)LOWER SLOPE TO TOP OF PONDING 3 GROUNDCOVERS / SHRUBS UPPER SLOPE / SURFACE GRADE ACCENT SHRUB (SELECT APPROPRIATE SHRUB BASED ON ZONE)SURFACE GRADE / LOWER SLOPE / FACILITY BOTTOM TREE CENTER WITHIN UPPER SLOPE. CONSIDER CANOPY OF FULL-GROWN TREE. ALLOW CLEARANCE FOR WALKWAYS. 1 2 3 1 2 3 3 2' MIN. OPTIONAL COMPACTED EARTH BERM, SEE NOTE 1 2" MIN. WASHED ROUND ROCK GENERAL NOTES: 1.UNDERDRAINS ARE NOT ALLOWED WITHIN RAIN GARDENS. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. OPTIONAL SURFACE OVERFLOW, SEE NOTE 3 6" BIRD CAGE OVERFLOW, NDS 80 OR EQUAL. SET RIM AT TOP OF PONDING AND FASTEN TO DRAIN PIPE 45° ELBOW (TYP.) PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) RAIN GARDEN SECTION STD. PLAN - 260.10 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.ALL PERMEABLE PAVEMENT APPLICATIONS SHALL CONFORM TO THE CITY OF RENTON SURFACE WATER DESIGN MANUAL SECTION C.2.7 AND WSDOT LOCAL AGENCY GENERAL SPECIAL PROVISIONS. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. PERMEABLE PAVEMENT SECTION, SEE STD. PLAN 261.10 IMPERMEABLE PAVEMENT 6" 2" MIN. EMBEDMENT KEY FROM ADJACENT IMPERMEABLE PAVEMENT BASE CONCRETE BAND EXTEND TO BOTTOM OF PAVEMENT BASE FLUSH EDGES PERMEABLE PAVEMENT SECTION, SEE STD. PLAN 261.10 6" MIN. 4,000 PSI COMPRESSIVE STRENGTH CONCRETE BAND (TYP.) DEPRESS LANDSCAPING 1" NEXT TO EDGE TREATMENT LANDSCAPE EXTEND TO BOTTOM OF PAVEMENT BASE KEY OR EXPANSION JOINT PER DPW APPROVAL (TYP.) CONCRETE BAND BETWEEN PAVEMENT CONCRETE BAND AT LANDSCAPE PERMEABLE PAVEMENT - EDGE TREATMENTS STD. PLAN - 261.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.PERMEABLE PAVEMENT THICKNESSES LISTED FOR POROUS ASPHALT INCLUDE WEARING COURSE AND ASPHALT TREATED PERMEABLE BASE (ATPB) WHEN UTILIZED. PERMEABLE ASPHALT TREATED BASE (PATB) SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-SA2. CHOKER COURSE REQUIRED WHEN ATPB IS USED. 2.CRUSHED SURFACING CHOKER COURSE (CSCC) SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04.2(9-03.9(2)).OPT2. 3.AGGREGATE BASE SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04.2(9-03.9(2)).OPT1. RUNOFF STORAGE REQUIREMENTS MAY REQUIRE A THICKER AGGREGATE BASE. HYDRAULIC MODELING RESULTS SHOWING THE REQUIRED AGGREGATE BASE THICKNESS FOR STORMWATER CONTROL MUST BE SUBMITTED. 4.PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS. COMPACT TO A DEPTH OF 6" TO 90%-92% OF MAXIMUM DENSITY PER WSDOT 2-03.3(14)D. OVERCOMPACTED SUBGRADE SHALL BE SCARIFIED TO 8" MIN. AND RECOMPACTED. 5.PERMEABLE PAVEMENT SUBJECT TO VEHICULAR USE (POLLUTION-GENERATING) SHALL BE DESIGNED WHERE THE SOIL BENEATH THE BMP MEETS A MINIMUM ORGANIC MATTER CONTENT OF 1.0% AND A MINIMUM CATION EXCHANGE CAPACITY OF 5 MILLIEQUIVALENTS PER 100 GRAMS. WHERE THE NATIVE SOIL DOES NOT MEET THESE PROPERTIES, A 6-INCH SAND LAYER IS REQUIRED BENEATH THE AGGREGATE BASE LAYER OF THE PERMEABLE PAVEMENT. 6.PAVEMENT BASE SHALL BE INSTALLED PER APWA GSP 4-04.3(5) SHAPING AND COMPACTION. PERVIOUS CONCRETE/POROUS ASPHALT MINIMUM MATERIAL THICKNESS (IN): A B SUBGRADE, SEE NOTE 4 PAVEMENT BASE, SEE NOTE 6 RESIDENTIAL STREETS AND ALLEYS PEDESTRIAN LAYER MATERIAL TYPE* PERVIOUS CONCRETE (IN) POROUS ASPHALT (IN) PERVIOUS CONCRETE (IN) POROUS ASPHALT (IN) PERMEABLE PAVEMENT, SEE NOTE 1 8 6 5 4 CHOKER COURSE, SEE NOTE 2 0 2 0 2 AGGREGATE BASE, SEE NOTE 3 8 6 6 4 A B C C GENERAL NOTES: 1.REFER TO WSDOT LOCAL AGENCY GENERAL SPECIAL PROVISIONS (GSPs) DIVISIONS 2-9 APWA GSPs, AND WSDOT STANDARD SPECIFICATIONS. 2.POROUS HMA SHALL CONFORM TO REQUIREMENTS OF APWA GSP 5-04. 3.MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 265.00, 265.10, AND 265.20, AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 4.PERMEABLE PAVEMENT SHALL BE DESIGNED OR REVIEWED BY A LICENSED ENGINEERING GEOLOGIST OR GEOTECHNICAL ENGINEER. FOR ALL APPLICATIONS, PAVEMENT DESIGNS MUST BE PREPARED BY AN ENGINEER LICENSED IN WASHINGTON STATE. 5.ACCEPTANCE TESTING FOR SIDEWALKS, PATHS AND VEHICULAR PAVEMENT LESS THAN 2,000 SF SHALL BE AS FOLLOWS: PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. APPROVAL WITH 5 GALLON BUCKET TEST, WATER TRUCK, OR ASTM C1701 USING A 12-INCH RING SEALED AT THE PAVEMENT SURFACE. 6.ACCEPTANCE TESTING FOR ROADWAYS AND PARKING AREAS OF 2,000 SF OR GREATER SHALL HAVE A MINIMUM INFILTRATION RATE OF 100 IN/HR PER ASTM C1701 AND APWA GSP 5-04.3 AND 5-06.3(6). 7.ROADWAYS, DRIVEWAYS, AND PARKING LOTS SUBJECT TO VEHICLE LOADING SHALL MEET STRUCTURAL REQUIREMENTS OF CITY OF RENTON TRANSPORTATION DEPARTMENT STANDARDS FOR EQUIVALENT NON-PERMEABLE PAVEMENT TYPES. 8.FOR PERMEABLE PAVEMENT INSTALLATIONS ON SLOPES GREATER THAN 5%, CHECK DAMS AREA REQUIRED PER STD. PLAN 261.20. 9.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. SAND LAYER (IF REQUIRED), SEE NOTE 5 PERVIOUS CONCRETE/POROUS ASPHALT 12" MIN. ABOVE SEASONAL HIGH GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER PERMEABLE PAVEMENT MATERIAL SECTIONS - PERVIOUS CONCRETE AND POROUS ASPHALT STD. PLAN - 261.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST NOTES: 1.UNDERDRAIN AGGREGATE SHALL MEET GRAVEL BACKFILL FOR DRAINS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(4). 2.UNDERDRAIN TO BE 6" MIN. (PRIVATE), 8" MIN. (PUBLIC) SLOTTED PVC, SDR 35 PER ASTM D3034. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS OF THE PIPE AND BE 0.04 TO 0.069 INCHES BY 1 INCH LONG AND BE SPACED 0.25 INCHES APART (SPACED LONGITUDINALLY). SLOTS SHOULD BE ARRANGED IN FOUR ROWS SPACED ON 45-DEGREE CENTERS AND COVER 1/2 OF THE CIRCUMFERENCE OF THE PIPE. SLOPE PIPE AT 0.5% MIN. UNLESS OTHERWISE SPECIFIED. PROVIDE ONE CLEANOUT MIN. PER 100 FEET OF UNDERDRAIN, AND AT EACH END. SEE STD. PLAN 226.00. 3.PIPE WILL HAVE A MINIMUM COVER DEPTH OF 12" AND BEDDING DEPTH OF 6". SEE PERMEABLE PAVEMENT SECTION STD. PLAN 261.10 DESIGNER TO SPECIFY CHECK DAM HEIGHT 3" MIN. KEY 12" MIN. DESIGNER TO SPECIFY DESIGNER TO SPECIFY SPACING DESIGNER TO SPECIFY SPACING 4" MIN. 10% MAX. SLOPE 1" MIN. CHECK DAM CLEARANCE 1 1 6" 6" MIN. BEDDING SEE PERMEABLE PAVEMENT SECTION STD. PLAN 261.10 10% MAX. SLOPE 1" MIN. CHECK DAM CLEARANCE OUTFLOW SEE PERMEABLE PAVEMENT SECTION STD. PLAN 261.10 2" MIN. 12" MIN. COVER 12" MIN. 12" MIN. SUMP CONTROLLED DENSITY FILL SUBSURFACE CHECK DAM 12" MIN. CLEAR CONCRETE BAND SUBSURFACE CHECK DAM UNDERDRAIN AND OVERFLOW CONTROL STRUCTURE WITH RISER GENERAL NOTES: 1.LOCATE UNDERDRAIN BELOW STRUCTURAL PAVEMENT BASE DEPTH. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. CONTROLLED DENSITY FILL SUBSURFACE CHECK DAM PER WSDOT SECTION 2-09.3(1)E (TYP.). CHECKDAM REQUIRED FOR SLOPE STEEPER THAN 5% COMMERCIAL CONCRETE SUBSURFACE CHECK DAM PER WSDOT SECTION 6-02.3(2)B (TYP.). CHECKDAM REQUIRED FOR SLOPE STEEPER THAN 5% DESIGN WATER SURFACE ELEVATION CONTROLLED BY OUTLET CONTROL JOINT (TYP.) (PERVIOUS CONCRETE ONLY) SLOTTED UNDERDRAIN, SEE NOTES 2 AND 3 DESIGN WATER SURFACE ELEVATION CONTROLLED BY OUTLET CONTROL JOINT (TYP.) (PERVIOUS CONCRETE ONLY) CLEANOUT PER STD. PLAN 226.00 WATER LEVEL CONTROLLED BY OUTLET ELEVATION OUTLET ELEVATION, DESIGNER TO SPECIFY TYPE 1L CATCH BASIN (CB) PER STD. PLAN 200.10 OR OTHER STRUCTURE WITH APPROVAL UNDERDRAIN AGGREGATE, SEE NOTE 1 REMOVABLE PLUG FOR MAINTENANCE SLOTTED UNDERDRAIN PIPE, SEE NOTES 2 AND 3 SANITARY TEE WITH OPTIONAL RISER PIPE DESIGNER TO SPECIFY SUBSURFACE CHECK DAM HEIGHT 3" MIN. KEY 6" MIN. BEDDING SLOTTED UNDERDRAIN, SEE NOTES 2 AND 3 12" MIN. COVER 1 1 3' MAX. SUBGRADE PER STD. PLAN 261.19 SUBGRADE PER STD. PLAN 261.10 6" SUBGRADE PER STD. PLAN 261.10 PERMEABLE PAVEMENT - SUBSURFACE CHECK DAMS AND UNDERDRAIN STD. PLAN - 261.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST 2% 1 2.5 MIN. 1 2.5 MIN. GENERAL NOTES: 1.MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 265.00, 265.10, AND 265.20, AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 2.BSM PLACEMENT, GRADING, AND CONSOLIDATION SHALL NOT OCCUR WHEN THE BSM IS EXCESSIVELY WET OR HAS BEEN SUBJECTED TO MORE THAN 1/2" OF PRECIPITATION WITHIN 48 HOURS PRIOR TO PLACEMENT. EXCESSIVELY WET IS DEFINED AS BEING AT OR ABOVE 22% SOIL MOISTURE BY A GENERAL TOOLS AND INSTRUMENTS DSMM500 PRECISION DIGITAL SOIL MOISTURE METER WITH PROBE (OR EQUIVALENT). THERE SHOULD BE NO VISIBLE FREE WATER IN THE MATERIAL. THE CONTRACTOR SHALL PLACE BSM LOOSELY WITH A CONVEYOR BELT OR WITH AN EXCAVATOR OR LOADER FROM A HEIGHT NO HIGHER THAN 6 FEET, UNLESS OTHERWISE APPROVED BY THE ENGINEER (I.E., DO NOT DUMP MATERIAL DIRECTLY FROM TRUCK INTO CELL). COMPACT BSM USING NON-MECHANICAL COMPACTION METHODS (E.G., BOOT PACKING, HAND TAMPING, OR WATER CONSOLIDATION) TO 83% (± 2%) OF THE MAXIMUM DRY DENSITY PER MODIFIED PROCTOR TEST (ASTM D1557), OR AS DIRECTED BY THE ENGINEER. 3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. NOTES: 1.AVOID COMPACTION OF EXISTING SUBGRADE BELOW BASIN. 2.SCARIFY SUBGRADE TO A DEPTH OF 3 INCHES MINIMUM IMMEDIATELY PRIOR TO PLACEMENT OF BIORETENTION SOIL MIX (BSM) AND UNDERDRAIN AGGREGATE. 3.18" MIN. BIORETENTION SOIL MIX ON BOTTOM AND SIDES TO TOP OF PONDING AREA. BIORETENTION SOIL MIX TO MEET STD. PLAN 262.60. 4.ARBORIST WOOD CHIP MULCH TO MEET STD. PLAN 262.60. 5.DO NOT USE FILTER FABRIC BETWEEN SUBGRADE AND THE BIORETENTION SOIL MIX. 6.MAXIMUM LONGITUDINAL SLOPE (ALONG DIRECTION OF FLOW) OF BIORETENTION SWALES SHALL BE 6%. 7.WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6 INCHES MINIMUM AND INCREASE SIDE SLOPE TO 1.5H:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. 1.5 1 FOR EDGE TREATMENT OPTIONS, SEE STD. PLAN 262.20 ROADWAY OR PARKING LOT TRANSITION ZONE SOIL, SEE STD. PLAN 262.20 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE NOTE 4 OVERFLOW TO STORM MAIN SIDEWALK, LANDSCAPING, DRIVEWAY, OR PAVEMENT ANGLE OF REPOSE DESIGNER TO SPECIFY WATER STORAGE ELEVATION TOP OF BANK ELEVATION SCARIFIED AND UNCOMPACTED SUBGRADE, SEE NOTES 1 AND 2 OVERFLOW STRUCTURE PER STD. PLAN 262.40 UNLESS SPECIFIED OTHERWISE BIORETENTION SOIL MIX (BSM), SEE NOTE 3 GRAVEL BASE, SEE STD. PLAN 262.40 SEE STD. PLAN 262.20 1" 6" 2"-12" PONDING DEPTH 18" MIN. SEE STD. PLAN 262.20 BOTTOM WIDTH MIN. 18" 6" MIN. FREEBOARD 12" MIN. ABOVE SEASONAL HIGH GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER SIDE SLOPE AT TREE, SEE NOTE 7 BIORETENTION SECTION (NO UNDERDRAIN) STD. PLAN - 262.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST NOTES: 1.AVOID COMPACTION OF EXISTING SUBGRADE BELOW BASIN. 2.SCARIFY SUBGRADE TO A DEPTH OF 3 INCHES MINIMUM IMMEDIATELY PRIOR TO PLACEMENT OF BIORETENTION SOIL MIX AND UNDERDRAIN AGGREGATE, EXCEPT WHEN LINER IS REQUIRED. 3.LINER TO BE INSTALLED ONLY WHEN REQUIRED IN THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). LOW PERMEABILITY LINER TO BE 30 MIL MIN. GEOMEMBRANE LINER OR 12 INCHES MIN. (DRY) CLAY LINER. CLAY LINER TO BE COMPACTED TO 95% MINIMUM DRY DENSITY (ASTM D698), WITH AT LEAST 30% CLAY PARTICLES PASSING (ASTM D422) AND AT LEAST 15% PLASTICITY INDEX (ASTM D4318). 4.UNDERDRAIN TO BE 6" MIN. (PRIVATE), 8" MIN. (PUBLIC) SLOTTED PVC, SDR 35 PER ASTM D3034. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS OF THE PIPE AND BE 0.04 TO 0.069 INCHES BY 1 INCH LONG AND BE SPACED 0.25 INCHES APART (SPACED LONGITUDINALLY). SLOTS SHOULD BE ARRANGED IN FOUR ROWS SPACED ON 45-DEGREE CENTERS AND COVER 1/2 OF THE CIRCUMFERENCE OF THE PIPE. SLOPE PIPE AT 0.5% MIN UNLESS OTHERWISE SPECIFIED. PROVIDE ONE CLEANOUT MIN. PER 100 FEET OF UNDERDRAIN, AND AT EACH END. SEE STD. PLAN 226.00. MATCH CROWN ELEVATION OF UNDERDRAIN TO OVERFLOW PIPE UNLESS OTHERWISE SPECIFIED. 5.18" MIN. BIORETENTION SOIL MIX ON BOTTOM AND SIDES TO TOP OF PONDING AREA. BIORETENTION SOIL MIX TO MEET STD. PLAN 262.60. 6.UNDERDRAIN AGGREGATE TO MEET GRAVEL BACKFILL FOR DRAINS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(4). 7.ARBORIST WOOD CHIP MULCH TO MEET STD. PLAN 262.60. 8.MAXIMUM LONGITUDINAL SLOPE (ALONG DIRECTION OF FLOW) OF BIORETENTION SWALES SHALL BE 6%. 9.WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6 INCHES MINIMUM AND INCREASE SIDE SLOPE TO 1.5H:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. 2% 1 2.5 MIN. 1 2.5 MIN. 1.5 1 GENERAL NOTES: 1.MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 265.00, 265.10, AND 265.20, AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 2.BSM PLACEMENT, GRADING, AND CONSOLIDATION SHALL NOT OCCUR WHEN THE BSM IS EXCESSIVELY WET OR HAS BEEN SUBJECTED TO MORE THAN 1/2" OF PRECIPITATION WITHIN 48 HOURS PRIOR TO PLACEMENT. EXCESSIVELY WET IS DEFINED AS BEING AT OR ABOVE 22% SOIL MOISTURE BY A GENERAL TOOLS AND INSTRUMENTS DSMM500 PRECISION DIGITAL SOIL MOISTURE METER WITH PROBE (OR EQUIVALENT). THERE SHOULD BE NO VISIBLE FREE WATER IN THE MATERIAL. THE CONTRACTOR SHALL PLACE BSM LOOSELY WITH A CONVEYOR BELT OR WITH AN EXCAVATOR OR LOADER FROM A HEIGHT NO HIGHER THAN 6 FEET, UNLESS OTHERWISE APPROVED BY THE ENGINEER (I.E., DO NOT DUMP MATERIAL DIRECTLY FROM TRUCK INTO CELL). COMPACT BSM USING NON-MECHANICAL COMPACTION METHODS (E.G., BOOT PACKING, HAND TAMPING, OR WATER CONSOLIDATION) TO 83% (± 2%) OF THE MAXIMUM DRY DENSITY PER MODIFIED PROCTOR TEST (ASTM D1557), OR AS DIRECTED BY THE ENGINEER. 3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. ANGLE OF REPOSE SCARIFIED AND UNCOMPACTED SUBGRADE, SEE NOTES 1 AND 2 OVERFLOW STRUCTURE PER STD. PLAN 262.40 UNLESS SPECIFIED OTHERWISE 1" 6" 2"-12" PONDING DEPTH 18" MIN. BOTTOM WIDTH MIN. 18" 6" MIN. FREEBOARD FOR EDGE TREATMENT OPTIONS, SEE STD. PLAN 262.20 ROADWAY OR PARKING LOT TRANSITION ZONE SOIL, SEE STD. PLAN 262.20 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE NOTE 7 DESIGNER TO SPECIFY WATER STORAGE ELEVATION TOP OF BANK ELEVATION OVERFLOW TO STORM MAIN LOW PERMEABILITY LINER WHEN REQUIRED, SEE NOTE 3 GRAVEL BASE, SEE STD. PLAN 262.40 12" MIN. UNDERDRAIN AGGREGATE, SEE NOTE 6 UNDERDRAIN, SEE NOTE 4 BIORETENTION SOIL MIX (BSM), SEE NOTE 5 SIDE SLOPE AT TREE, SEE NOTE 9 SIDEWALK, LANDSCAPING, DRIVEWAY, OR PAVEMENT SEE STD. PLAN 262.20 SEE STD. PLAN 262.20 BIORETENTION SECTION (WITH UNDERDRAIN) STD. PLAN - 262.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST BIORETENTION ADJACENT TO SIDEWALK, LANDSCAPING, DRIVEWAY, OR PAVEMENT WITH FLUSH CURB OR NO CURB NOTES: 1.THE FOLLOWING MINIMUM SETBACKS SHALL BE PROVIDED FOR FACILITIES WITH SLOPED SIDES ADJACENT TO CURB: 1.1.4-FOOT MIN. FROM FACE OF CURB TO TOP OF SLOPE ADJACENT TO MAJOR ARTERIAL STREET. 1.2.2-FOOT MIN. FROM FACE OF CURB TO TOP OF SLOPE ADJACENT TO MINOR ARTERIAL AND COLLECTOR ARTERIAL STREET. 1.3.1-FOOT MIN. FROM FACE OF CURB TO TOP OF SLOPE ADJACENT TO NON-ARTERIAL STREET OR PARKING LOT WITH NON-FLUSH CURB. 2.THE FOLLOWING MINIMUM SETBACKS SHALL BE PROVIDED FOR FACILITIES WITH SLOPED SIDES ADJACENT TO FLUSH CURB OR NO CURB: 2.1.2-FOOT MIN. FROM EDGE OF DRIVEWAY OR PAVEMENT TO TOP OF SLOPE ADJACENT TO DRIVEWAY OR PAVEMENT. 2.2.1-FOOT MIN. FROM EDGE OF SIDEWALK OR LANDSCAPING TO TOP OF SLOPE ADJACENT TO SIDEWALK OR LANDSCAPING. 3.COMPACT TRANSITION ZONE SOIL IMMEDIATELY BEHIND CURB TO 90% MAX. STANDARD PROCTOR DENSITY (ASTM D698). 4.TRANSITION ZONE SOIL SHALL BE BIORETENTION SOIL MIX OR AMENDED SOIL PER GENERAL NOTE 1. 5.18" MINIMUM BIORETENTION SOIL MIX PER STD. PLAN 262.60 TO TOP OF PONDING DEPTH. 2% SEE NOTE 2 6" MIN. FREEBOARD 1" 1" 2% 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 SIDEWALK, LANDSCAPING, DRIVEWAY, OR PAVEMENT TOP OF PONDING BIORETENTION SOIL MIX, SEE NOTE 5 CONCRETE CURB, SEE STD. PLAN 101 ROADWAY OR PARKING LOT TRANSITION ZONE SOIL, SEE NOTES 3 AND 4 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 BIORETENTION SOIL MIX, SEE NOTE 5 TOP OF PONDING TOP OF BANK ELEVATION 6" 6" MIN. FREEBOARD BIORETENTION ADJACENT TO CURB GENERAL NOTES: 1.SOIL AMENDMENT: SCARIFY OR TILL SUBGRADE TO 3-INCH DEPTH. PLACE 3-INCHES OF TOPSOIL ON SURFACE AND TILL INTO 5-INCHES OF SITE SOIL. SCARIFICATION DOES NOT APPLY TO LINED FACILITIES. TOPSOIL SHALL HAVE A MINIMUM ORGANIC MATTER CONTENT OF 10% DRY WEIGHT IN PLANTING BEDS AND 5% IN TURF AREAS, AND A pH FROM 6.0 TO 8.0 OR MATCHING THE pH OF THE ORIGINAL UNDISTURBED SOIL. 2.SEE STD. PLAN 262.30 FOR CURB CUTS. 3.FOR FACILITIES WITH LINERS, PROVIDE LINER ANCHOR PER WSDOT SPECIFICATIONS 8-29.3(2). 4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. TRANSITION ZONE SOIL, SEE NOTES 3 AND 4 6" SEE NOTE 1 BIORETENTION - EDGE TREATMENTS STD. PLAN - 262.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT PLAN INFLOW MATCH GUTTER WIDTH MATCH CURB WIDTH 12" MIN. 18"-24"" DESIGNER TO SPECIFY, SEE NOTE 2 6" MIN. 3'-6" MIN. 6" TAPER, (TYP.) 6" TAPER GUTTER AT CURB CUT TO MATCH GUTTER SLOPE UPSLOPE AND DOWNSLOPE OF CURB CUTROADWAY STREAMBED COBBLES, SEE NOTE 3 12" A ROADWAYINFL O W CURB SEE NOTE 1 SPLASH APRON GENERAL NOTES: 1.BOND NEW CURB AND GUTTER TO EXISTING CURB AND GUTTER WITH EPOXY AND DOWEL CONNECTION, IF RETROFITTING INTO EXISTING CURBLINE. REFER TO STD. PLAN 101.10 FOR EXPANSION JOINT DETAIL. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. ROADWAY SLOPE INFLOW 2.5 1 SECTION A 2" GUTTER DEPRESSION AT FLOWLINE 18''1" DROP TO COBBLES 6" MIN. FREEBOARD BIORETENTION FACILITY GUTTER UPSLOPE AND DOWNSLOPE OF CURB CUT TYPICAL SIDE SLOPE COMPACT SOIL BELOW COBBLES, SEE NOTE 4 NOTES: 1.SEE STD. PLAN 262.20 FOR EDGE TREATMENT OUTSIDE INLET AREA. 2.INLET CURB CUT WIDTH SHALL BE 24" ON GUTTER SLOPES ≥ 5% AND 18" ON GUTTER SLOPES < 5%. 3.STREAMBED COBBLES SHALL BE 6" COBBLES PER WSDOT 9-03.11(2). COBBLE PAD TO BE 8" THICK, WITH 1:1 SIDE SLOPES, TAPERING TO 12'' WIDE AT FACILITY BOTTOM. 4.COMPACT BIORETENTION SOIL MIX UNDER COBBLES TO 90% MAX STANDARD PROCTOR DENSITY (ASTM D698). 4" CRUSHED SURFACING TOP COURSE 8" UNCOMPACTED BIORETENTION SOIL MIX (BSM), SEE STD. PLAN 262.60 2"-4" ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 18" MIN. 1 1 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) BIORETENTION - CURB CUT INLETS STD. PLAN - 262.30 A DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: 1.FRAME AND GRATE SHALL BE LOCKING AND GRATE SHALL BE BOLTED TO FRAME. FRAME SHALL CONFORM TO WSDOT STANDARD PLAN B-30.10-03. GRATE TO BE DUCTILE IRON BEEHIVE GRATE FITTING 20"x24" FRAME. OLYMPIC FOUNDRY PART SM60BH OR EQUAL. SEE STANDARD SPECIFICATIONS 9-05.15(2). 2.MINIMUM STREAMBED COBBLE DIAMETER SHALL BE LARGER THAN MAXIMUM GRATE OPENING. 3.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 4.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 6" MIN. CAST IRON BEEHIVE GRATE AND FRAME, SEE NOTE 1 CATCH BASIN TYPE 1 PER STD. PLAN 200.00 OR OTHER STRUCTURE WITH APPROVAL CATCH BASIN ADJUSTMENT SECTION AS REQUIRED, DESIGNER TO SPECIFY ELEVATION 12" MIN. SUMP 6" MIN. 6" MIN. VARIES, 5' MAX. CONCRETE BASE DESIGN PONDING ELEVATION GRAVEL BACKFILL FOR DRAINS, COMPACT PER WSDOT STD. SPEC . 9-03.12(4) STORM DRAIN PIPE, DESIGNER TO SPECIFY SEE NOTE 4 (TYP.) UNDERDRAIN PIPE, IF REQUIRED, SEE STD. PLAN 262.10 OPTIONAL 6" OR 8" STREAMBED COBBLES, PER WSDOT 9-03.11(2), SEE NOTE 2 SEE NOTE 3 GENERAL NOTES: 1.PLANT SPACING WITHIN FACILITY TO ALLOW MAINTENANCE ACCESS TO STRUCTURE. 2.12-INCH MIN. CLEARANCE WITHIN OVERFLOW STRUCTURE SHALL BE PROVIDED FOR MAINTENANCE ACCESS. 3.OVERFLOW PIPES MUST BE LOCATED AT AN ELEVATION HIGHER THAN THE STORM DRAIN HYDRAULIC GRADE LINE TO PREVENT BACKFLOW INTO THE BIORETENTION FACILITY. 4.OVERFLOW STRUCTURE SHALL BE LOCATED WITHIN 10 FEET OF ROAD EDGE FOR MAINTENANCE ACCESS, UNLESS APPROVED OTHERWISE. OVERFLOW STRUCTURE MAY BE LOCATED IN SIDE SLOPES. 5.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. BIORETENTION - OVERFLOW OUTLET STRUCTURE STD. PLAN - 262.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST TABLE: PLANTING ZONES ZONE PLANT TYPE LOCATION 1 EMERGENTS, PERENNIALS & LOW SHRUBS (PLANTS THAT CAN TOLERATE STANDING WATER)FACILITY BOTTOM 2 EMERGENTS, PERENNIALS & LOW SHRUBS (PLANTS THAT CAN TOLERATE OCCASIONAL STANDING WATER) LOWER SLOPE TO TOP OF PONDING 3 GROUNDCOVERS / SHRUBS UPPER SLOPE / SIDEWALK GRADE ACCENT SHRUB (SELECT APPROPRIATE SHRUB BASED ON ZONE)SIDEWALK GRADE / LOWER SLOPE / FACILITY BOTTOM TREE UPPER SLOPE, SEE NOTE 1 NOTES: 1.WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6" MIN. AND INCREASE SIDE SLOPE TO 1.5H:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. ROADWAY TRANSITION ZONE SOIL, SEE STD. PLAN 262.20 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 BIORETENTION SOIL MIX, SEE STD. PLAN 262.60 SIDEWALK OR LANDSCAPING SCARIFIED AND UNCOMPACTED SUBGRADE 2"-12" PONDING DEPTH 18" MIN. BOTTOM WIDTH MIN. 18" 3 2 1 2 3 PLANTING ZONES, SEE BELOW 1 2 3 1 2 3 3 GENERAL NOTES: 1.ALL PLANTS SHALL BE SELECTED WITH A MAXIMUM MATURE HEIGHT NOT GREATER THAN 30-INCHES ABOVE THE TOP OF THE FACILITY, WITH THE EXCEPTION OF TREES AND ACCENT SHRUBS. 2.SEE STD. PLANS 262.00, 262.10, AND 262.20 FOR SECTION VIEWS OF BIORETENTION FACILITIES. 3.SEE THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) TABLE C.2.6.A FOR A SELECTION OF APPROVED WATER TOLERANT PLANTS. ADDITIONAL SPECIES ARE ALLOWED WITH CITY APPROVAL. 4.SELECT A MINIMUM OF 50% EVERGREEN PLANTS. 5.PLANTS ADJACENT TO STREET, DRIVEWAY, OR SIDEWALK SHALL BE SELECTED AND SPACED TO ALLOW ACCESS TO VEHICLES AND NOT IMPEDE PEDESTRIANS. 6.PLANTS SHALL BE SPACED TO ENSURE CLEAR ACCESS AND UNIMPEDED FLOW FROM INLETS, OUTLETS, AND OVERFLOWS. 7.CONTINUE MULCH FOR A MINIMUM OF 2-FEET PAST THE TOP OF BANK ELEVATION OR INSTALL LANDSCAPE EDGING IF FACILITY IS ADJACENT TO TURF. 8.PLANTING DESIGN SHOULD MINIMIZE COMPACTION OF BIORETENTION SOIL MIX THROUGH PLANNED MAINTENANCE ACCESS. ANNUAL PLANTS REQUIRING SOIL DISTURBANCE FOR HARVESTING (E.G., CARROTS) OR ANNUAL REPLANTING ARE NOT PERMITTED. 9.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 6" MIN. 1.5 1 SIDE SLOPE AT TREE, SEE NOTE 1 BIORETENTION PLANTING - SECTION VIEW STD. PLAN - 262.50 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT BIORETENTION SOIL MIX, COMPOST, AND MULCH SPECIFICATIONS STD. PLAN - 262.60 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) BIORETENTION SOIL MIX BIORETENTION SOIL MIX (BSM) SHALL BE A WELL-BLENDED HOMOGENEOUS MIXTURE OF 60 TO 65 PERCENT BY VOLUME MINERAL AGGREGATE FOR BIORETENTION SOIL AND 35 TO 40 PERCENT BY VOLUME COMPOST AS DETAILED IN THE TABLES BELOW. TABLE: MINERAL AGGREGATE GRADATION SIEVE SIZE PERCENT PASSING 3/8-INCH 100 PERCENT U.S. NO. 4 95 TO 100 PERCENT U.S. NO. 10 75 TO 90 PERCENT U.S. NO. 40 25 TO 40 PERCENT U.S. NO. 100 4 TO 10 PERCENT U.S. NO. 200 2 TO 4 PERCENT COMPOST COMPOST MUST ORIGINATE A MINIMUM 65 PERCENT BY VOLUME FROM RECYCLED PLANT WASTE COMPRISED OF YARD DEBRIS, CROP RESIDUES, AND BULKING AGENTS, AND MEET THE DEFINITION OF "COMPOSTED MATERIAL" IN WAC 173-350-100. COMPOST SHALL HAVE A MOISTURE CONTENT THAT HAS NO VISIBLE FREE WATER OR DUST PRODUCED WHEN HANDLING THE MATERIAL. COMPOST SHALL HAVE AN ORGANIC MATTER CONTENT OF 40 PERCENT TO 65 PERCENT BY DRY WEIGHT, A CARBON TO NITROGEN RATIO BELOW 25:1, AND A pH BETWEEN 6.0 AND 8.0 TABLE: COMPOST GRADATION SIEVE SIZE MIN. PERCENT PASSING 2-INCH 100 PERCENT 1-INCH 99 PERCENT 5/8-INCH 90 PERCENT 1/4-INCH 75 PERCENT ABORIST WOOD CHIP MULCH ARBORIST WOOD CHIP MULCH SHALL BE COARSE GROUND WOOD CHIPS (APPROXIMATELY 1/2" TO 6" ALONG THE LONGEST DIMENSION) DERIVED FROM THE MECHANICAL GRINDING OR SHREDDING OF THE ABOVE-GROUND PORTIONS OF TREES. IT MAY CONTAIN WOOD, WOOD FIBER, BARK, BRANCHES, AND LEAVES, BUT MAY NOT CONTAIN WEEDS, WEED SEEDS, OR VISIBLE AMOUNTS OF SOIL. TABLE: ARBORIST WOOD CHIP MULCH GRADATION SIEVE SIZE PERCENT PASSING 6-INCH 100 PERCENT 2-INCH 95 TO 100 PERCENT 1-INCH 70 TO 100 PERCENT 5/8-INCH 0 TO 50 PERCENT U.S. NO. 4 0 TO 30 PERCENT MINERAL AGGREGATE FOR BIORETENTION SOIL MINERAL AGGREGATE FOR BIORETENTION SOIL MUST BE FREE OF WOOD, WASTE, COATING, OR ANY OTHER DELETERIOUS MATERIAL, AND ALL AGGREGATE PASSING THE NO. 200 SIEVE SIZE MUST BE NON-PLASTIC. MINERAL AGGREGATE MUST BE ANALYZED BY AN ACCREDITED LAB USING THE SIEVE SIZES NOTED IN THE TABLE TO THE LEFT, AND MUST MEET THE REQUIRED GRADATIONS. DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT PLAN HOUSE HOUSE FLOW 2% SLOPE (1% MIN.) 4" CAPPED PVC OR GRATE INLET AT SURFACE FOR OBSERVATION ROOF DOWNSPOUT OVERFLOW SPLASH BLOCK FINE MESH SCREEN, SS 304 10x10 OR SIMILAR 6" DIA.MIN. PVC, SDR 35 PER ASTM D3034 SIDES AND TOP OF ROCK LINED WITH NON-WOVEN GEOTEXTILE FOR SEPARATION PER WSDOT 9-33.2(1) CATCH BASIN (YARD DRAIN) ROOF DOWNSPOUT MIN. 12" X 12" CATCH BASIN (YARD DRAIN) DRYWELL SOLID LID OR GRATE MIN. 50 GALLON PLASTIC OR CONCRETE DRYWELL 15' MIN. AS REQUIRED, SEE NOTE 1 12'' MIN. TOPSOIL 12" MIN. ABOVE SEASONAL HIGH GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER 5' MIN. SETBACK FROM BUILDING 12'' MIN. SUMP 24" MIN. 24" MIN. GENERAL NOTES: 1.WHEN LOCATED IN COARSE SANDS AND COBBLES, DRYWELLS MUST CONTAIN A VOLUME OF GRAVEL EQUAL TO OR GREATER THAN 60 CUBIC FEET PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. WHEN LOCATED IN MEDIUM SANDS, DRYWELLS MUST CONTAIN AT LEAST 90 CUBIC FEET OF GRAVEL PER 1,000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED. 2.SPACING BETWEEN DRYWELLS SHALL BE A MINIMUM OF 10 FEET. 3.REGULAR MAINTENANCE INCLUDING CATCH BASIN (YARD DRAIN) CLEANING (EVERY 6 MONTHS MINIMUM) IS ESSENTIAL TO THE LONG-TERM FUNCTIONING OF DRYWELLS. 4.CONNECT INLET PIPE TO CONCRETE DRYWELL USING PRECAST HOLE OR CORE DRILLED HOLE. 5.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 48" MIN. DIA. SPLASH BLOCK SECTION 48" MIN. NOTES: 1.DRYWELLS MUST BE SET BACK AT LEAST 15 FEET FROM BUILDINGS WITH CRAWL SPACE OR BASEMENT ELEVATIONS THAT ARE BELOW THE OVERFLOW POINT OF THE DRYWELL. 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5). DRYWELL PLAN AND SECTION STD. PLAN - 263.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT WIDTH ≤ 25 FT FOR A 100-FT NVFS WIDTH ≤ 50 FT FOR A 200-FT NVFS ROCK STRIP TO BE 2' WIDE BY MIN. 4" THICK. 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5). EDGE OF UNDISTURBED NATIVE VEGETATION SHEET FLOW ≤ 5% SLOPE ≤ 15% SLOPE 100 FT MIN. NATIVE VEGETATED FLOWPATH SEGMENT (NVFS) IMPERVIOUS SURFACE PERVIOUS SURFACE GENERAL NOTES: 1.ALL TREES WITHIN THE NATIVE GROWTH RETENTION AREA AT THE TIME OF PERMIT APPLICATION SHALL BE RETAINED, ASIDE FROM APPROVED TIMBER HARVEST ACTIVITIES AND THE REMOVAL OF DANGEROUS AND DISEASED TREES. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. FULL DISPERSION SHEET FLOW - FLAT/MODERATE SLOPE DRIVEWAYS PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 263.10 DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT STREET 340'RIGHT-OF-WAY345'350'335'ASPHALT BERM DETAIL 175'170'STREETRIGHT-OF-WAYDRIVEWAY SLOPE PLAN - DRIVEWAY DISPERSION TRENCH DRIVEWAY SLOPE VARIES AND SLOPES TOWARD STREET (<15%) 25' MIN. 700 SQ FT MAX. BETWEEN BERMS, SEE NOTE 1 MIN. 2% CROSS SLOPE 6" MIN. PLAN - SHEET FLOW DISPERSION FROM A DRIVEWAY FLAT TO MODERATELY SLOPING DRIVEWAYS (<15%) 2-4" DRIVEWAY SLOPE ROCK STRIP TO BE 2' WIDE BY MIN. 4'' THICK. 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5). 10' MIN. GENERAL NOTES: 1.MAXIMUM VEGETATED FLOWPATH SLOPE IS 15% FOR ANY 20-FOOT REACH, AND MAY NOT EXCEED 20%. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. DISPERSION TRENCH DETAIL 24'' MIN. UNDISTURBED NATIVE SOIL 2'' X 6'' UNTREATED CEDAR OR RECYCLED PLASTIC BOARD DIAGONAL ASPHALT BERM, SEE NOTE 3 DISPERSION TRENCHCRUSHED ROCK OR GRAVEL 1" DROP 18" MIN. 6" MIN. 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5) 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 6'' MIN. 25' VEGETATED FLOWPATH, SEE NOTE 4 10' MIN. 10' VEGETATED FLOWPATH SEGMENT 20' MAX. WIDTH, SEE NOTE 2 NOTES: 1.SEE STD. PLAN 224.00 FOR ALTERNATE DISPERSION TRENCH IF CONTRIBUTING AREA EXCEEDS 700 SF. USE 10 LF OF TRENCH WITH NOTCH BOARD PER 700 SF TO MAX. 50 LF OF TRENCH. 2.20' MAX. WIDTH OF CONTRIBUTING IMPERVIOUS SURFACE FOR SHEET FLOW DISPERSION, UNLESS VEGETATED FLOWPATH IS INCREASED BY 10' FOR EACH ADDITIONAL 20' OF CONTRIBUTING SURFACE AREA. 3.SLOT DRAINS OR ASPHALT BERMS MAY BE USED TO DIRECT RUNOFF TO ROCK PADS OR DISPERSION TRENCHES IN VARIOUS CONFIGURATIONS. LAYOUTS SHOWN ARE ONLY EXAMPLES. 4.IF DISCHARGE IS TOWARD A STEEP SLOPE HAZARD AREA OR A LANDSLIDE HAZARD STEEPER THAN 15%, VEGETATED FLOWPATH MUST BE 50 FEET. NON-WOVEN GEOTEXTILE FOR SEPARATION PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 25' MIN. BASIC DISPERSION - FLAT/MODERATE SLOPE DRIVEWAYS PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 263.20 DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST GENERAL NOTES: 1.MAXIMUM VEGETATED FLOWPATH SLOPE IS 15% FOR ANY 20-FOOT REACH, AND MAY NOT EXCEED 20%. 2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.RIGHT-OF-WAYDRIVEWAY SLOPE 125'120'115'110'105'RIGHT-OF-WAY250'245'240'235'2" TO 4" ASPHALT BERM DETAIL PLAN - STEEP DRIVEWAY WITH DIAGONAL BERMS (≥15%) PLAN - STEEP DRIVEWAY WITH SLOTTED DRAINS (≥15%) 10' MIN. DISPERSION TRENCH DISPERSION TRENCH DETAIL 24'' MIN. UNDISTURBED NATIVE SOIL 2'' X 6'' UNTREATED CEDAR OR RECYCLED PLASTIC BOARD CRUSHED ROCK OR GRAVEL 1" DROP 18" MIN. 6" MIN. 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5) 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 6'' MIN. 25' MIN. VEGETATED FLOWPATH, SEE NOTE 2 NO OVERLAP OF FLOWPATHS 2'x3'x6" MIN. ROCK PAD, SEE NOTE 3 50' MIN. VEGETATED FLOWPATH 10' MIN. 25' MIN. VEGETATED FLOWPATH, SEE NOTE 2 NO OVERLAP OF FLOWPATH SEGMENTS 25' MIN. VEGETATED FLOWPATH, SEE NOTE 2 6" MIN. DRIVEWAY SLOPE STREETSLOT DRAIN, SEE NOTE 4 700 SQ. FT. MAX. BETWEEN DRAINS, SEE NOTE 1 700 SQ FT MAX. BETWEEN BERMS, SEE NOTE 1 STREETDIAGONAL ASPHALT BERM, SEE NOTE 4 AREA DRAIN, SEE NOTE 5 NOTES: 1.SEE STD. PLAN 224.00 FOR ALTERNATE DISPERSION TRENCH IF CONTRIBUTING AREA EXCEEDS 700 SF. USE 10 LF OF TRENCH WITH NOTCH BOARD PER 700 SF TO MAX. 50 LF OF TRENCH. 2.IF DISCHARGE IS TOWARD A STEEP SLOPE HAZARD AREA OR A LANDSLIDE HAZARD STEEPER THAN 15%, VEGETATED FLOWPATH MUST BE 50 FEET. 3.MATERIAL FOR ROCK PAD TO BE 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5).. 4.SLOT DRAINS OR ASPHALT BERMS MAY BE USED TO DIRECT RUNOFF TO ROCK PADS OR DISPERSION TRENCHES IN VARIOUS CONFIGURATIONS. LAYOUTS SHOWN ARE ONLY EXAMPLES. 5.MIN. 12"x12" AREA (YARD) DRAIN. DOWNSTREAM CONNECTED PIPE TO BE 6" DIA. MIN. PVC, SDR 35 PER ASTM D3034, SLOPED AT 1% MIN. NON-WOVEN GEOTEXTILE FOR SEPARATION PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 25' MIN. DISPERSION TRENCH 25' MIN. BASIC DISPERSION - STEEP SLOPE DRIVEWAYS PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 263.30 DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST PLAN VIEW OF PARCEL TO STORM DRAIN SYSTEMRIGHT-OF-WAYGENERAL NOTES: 1.INFILTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM SINGLE-FAMILY OR DUPLEX HOMES OR TO CONTROL BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROL PROGRAM (UIC) FOR OTHER TYPES OF RUNOFF MANAGEMENT. 2.IMPERVIOUS AREAS LARGER THAN 10,000 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 35,000 SF MAY REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL ENGINEER. 3.THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25%. 4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 24" MIN. 18" MIN. MIN. 1' ABOVE SEASONAL HIGH GROUNDWATER TABLE 6" MIN. 3/4" - 1 1/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD. SPECIFICATION SECTION 9-03.12(5) NON-WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 COMPACTED TOPSOIL OR OTHER CLEAN FILL 6" DIA. MIN. PERFORATED PVC, SDR 35 PER ASTM D3034 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL ASECTION A NOTES: 1.TRENCH LENGTH TO BE 10 FEET IN LENGTH FOR EVERY 5,000 SF OF CONTRIBUTING IMPERVIOUS SURFACE, OR 35,000 SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTION THEREOF. 5' MIN. 5' MIN. TO STORM DRAIN SYSTEM 5' MIN. 5' MIN. A DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 CONFIGURATION ON FLAT GROUND CONFIGURATION ON SLOPING GROUND UNDISTURBED NATIVE SOIL CLEANOUT PER STD. PLAN 226.00 CLEANOUT PER STD. PLAN 226.00 FILTER SCREEN 2'-5' TO GROUND SOLIDS/ LEAVES TYPICAL DOWNSPOUT FILTER DETAIL FOOTING DRAIN BYPASS CLEANOUT PER STD. PLAN 226.00 PERFORATED STUB-OUT CONNECTION PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 263.40 DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST OPTION 5 - IMPORTED TOPSOIL OPTIONS 2, 3, AND 4 - AMEND IN PLACE OR STOCKPILE AND AMEND 3"-4" ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 SUBSOIL SCARIFIED 4" BELOW COMPOST AMENDED LAYER (12" BELOW SOIL SURFACE) GRASS: SEED OR SOD 1.75" OF COMPOST INCORPORATED INTO 6.25" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9.5", FOR A SETTLED DEPTH OF 8") SUBSOIL SCARIFIED 4" BELOW COMPOST AMENDED LAYER (12" BELOW SOIL SURFACE) PLANTING BEDS TURF (LAWN) AREAS 0" 8" 12" 3"-4" ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 SUBSOIL IS SCARIFIED 6" BELOW IMPORTED TOPSOIL MIX GRASS: SEED OR SOD 6" IMPORTED TOPSOIL MIX (COMPACTED DEPTH) SUBSOIL IS SCARIFIED 6" BELOW IMPORTED TOPSOIL MIX 0" 6" 12" PLANTING BEDS TURF (LAWN) AREAS 3" OF COMPOST INCORPORATED INTO 5" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9.5", FOR A SETTLED DEPTH OF 8") GRASS: SEED OR SOD PLANTING BEDS/UNDISTURBED VEGETATION, SEE NOTE 1 UNDISTURBED TURF (LAWN) AREAS, SEE NOTE 1 0" OPTION 1 - NO DISTURBANCE UNDISTURBED NATIVE SOIL UNDISTURBED NATIVE SOIL 6" IMPORTED TOPSOIL MIX (COMPACTED DEPTH) GENERAL NOTES: 1.TO MEASURE SETTLED DEPTH, WATER SOIL SUFFICIENTLY TO FULLY SATURATE WITHOUT CAUSING EROSION 2.COMPOST TO MEET STD. PLAN 262.60. 3.COMPACTION OF TOPSOIL (WHERE REQUIRED) TO BE TO 85% OF STANDARD PROCTOR. 4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNDISTURBED NATIVE VEGETATION NOTES: 1.AREAS OF NO DISTURBANCE TO BE FENCED AND EXISTING VEGETATION AND SOIL TO BE PROTECTED FROM CONSTRUCTION IMPACTS. SOIL AMENDMENT SECTIONS STD. PLAN - 264.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT GENERAL NOTES:1.ABANDONED UTILITIES WITHIN FOOTPRINT OF FACILITY AND OBSERVED DURING CONSTRUCTION MUST BE REMOVED. COORDINATE WITH MUNICIPAL OR PRIVATE OWNER AND ENGINEER.2.HORIZONTAL SEPARATION BETWEEN WATER MAIN WALL AND TOP OF SLOPE OF THE BIORETENTION FACILITY SHALL BE NO LESS THAN 7 FEET.3.FIRE HYDRANTS SHALL BE AT LEAST 5 FEET FROM BIORETENTION FACILITY FOOTPRINT.4.WATER METER SHALL BE LOCATED OUTSIDE BIORETENTION FACILITY FOOTPRINT.5.MANHOLES SHALL BE LOCATED OUTSIDE BIORETENTION FACILITY FOOTPRINT.6.A MINIMUM OF 1 FOOT SEPARATION BETWEEN SANITARY SEWER CROSSINGS AND UNDERDRAINS SHALL BE MAINTAINED.7.UTILITY SERVICE AND UTILITY MAIN CROSSINGS SHALL BE MADE PERPENDICULAR TO THE BIORETENTION FACILITY.8.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.1' MIN. CURB CUT TOEDGE OF CATCH BASINA,B,C265.10UTILITY MAINCROSSINGCATCH BASINUTILITY SERVICECROSSINGOPTIONAL UTILITY TRENCH DAM (TYP.),DESIGNER TO SPECIFYBIORETENTION FACILITYD 265.10UTILITY CROSSINGS - BIORETENTIONSTD. PLAN - 265.00PUBLIC WORKSDEPARTMENTAPPROVED:DATEGregg ZimmermanPublic Works AdministratorUNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA6388789/28/2018 | 9:45 AM PDT SCALE:SECTION - SHALLOW UTILITY SERVICEUNDER BIORETENTION FACILITYA265.00NTSEMBED LINER 3" MIN.INTO NATIVE SOILEXISTING UTILITY SERVICE TOREMAIN IN PLACE, SEE NOTE 1NATIVE SOIL,SEE NOTE 2EXISTING UTILITY SERVICE TOREMAIN IN PLACE, SEE NOTE 1NATIVE SOIL, SEE NOTE 2UTILITY SERVICEPIPE CASING PER STD. PLAN 412GENERAL NOTES:1.ANY DISCREPANCIES BETWEEN THE EXISTING UTILITIES SHOWN IN THE DESIGN DRAWINGS AND THE ACTUAL FIELD CONDITIONS SHOULD BE COMMUNICATED TO THE ENGINEER IMMEDIATELY.2.UTILITY MAINS SHALL NOT BE SUBJECT TO LOADING FROM NEW CURBS/WALLS. LOAD BEARING LINES TO BE DETERMINED BY THE GEOTECHNICAL ENGINEER.3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.DESIGNER TOSPECIFY MIN. PIPECOVER AS REQUIREDBY UTILITY PROVIDER,30" MIN.DESIGNER TO SPECIFY MIN. PIPE COVER ASREQUIRED BY UTILITYPROVIDER, 30" MIN.12" MIN.DESIGNER TO SPECIFYMIN. CLEARANCEAROUND UTILITY, SEE NOTE 3EMBED LINER 3" MIN.INTO NATIVE SOILEXISTING UTILITY MAIN TOREMAIN IN PLACE, SEE NOTE 1NATIVE SOIL,SEE NOTE 2DESIGNER TO SPECIFYMIN. CLEARANCE AROUNDUTILITY, SEE NOTE 3DESIGNER TOSPECIFY MIN. PIPECOVER AS REQUIREDBY UTILITY PROVIDER,30" MIN.30 MIL MIN. GEOMEMBRANELINER30 MIL MIN. GEOMEMBRANELINERDESIGNER TOSPECIFY MIN. PIPECOVER AS REQUIREDBY UTILITY PROVIDER,30" MIN.30 MIL MIN. GEOMEMBRANELINERSCALE:SECTION - SHALLOW UTILITY SERVICEWITHIN BIORETENTION FACILITYB265.00NTSSCALE:SECTION - ENCASED UTILITY SERVICEWITHIN BIORETENTION FACILITYC265.00NTSSCALE:SECTION - SHALLOW UTILITY MAINWITHIN BIORETENTION FACILITYD265.00NTSNOTES:1.CONTRACTOR SHALL LOCATE AND DETERMINE DEPTH OF EXISTING UTILITY WITHIN THE FOOTPRINT OF THE BIORETENTION FACILITY WHILE LIMITING THE AMOUNT OF DISTURBANCE TO THE SOIL/BACKFILL MATERIAL OVER ANDAROUND THE UTILITY PIPE. IF ELECTROMAGNETIC UTILITY LOCATING, POTHOLING, OR OTHER METHOD REVEALS THAT THE UTILITY PIPE DOES NOT MEET THE REQUIRED CLEARANCE FROM THE BOTTOM OF THE BIORETENTIONFACILITY, THE UTILITY PROVIDER MAY REQUIRE IMPLEMENTATION OF PROTECTION MEASURES THAT EXCEED STANDARDS SHOWN PER THEIR OWN STANDARDS OR REQUIRE THE EXISTING UTILITY TO BE RELOCATED OUT OFTHE BIORETENTION SECTION.2.EXISTING UTILITIES AND NATIVE SOIL AROUND EXISTING UTILITIES SHOULD REMAIN IN PLACE WHERE POSSIBLE. IF A PORTION OR ALL OF THE UTILITY IS UNCOVERED DURING EXCAVATION OR EXISTING SOIL WITHIN 1 FOOT OFTHE KNOWN EXISTING UTILITY IS SCARIFIED, NATIVE SOIL OR APPROVED ENGINEERED BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED AROUND THE UTILITY PER THE UTILITY PROVIDER'S REQUIREMENTS.3.PROVIDE THE MINIMUM CLEARANCE AROUND THE UTILITY SERVICE OR MAIN AND SETBACKS FROM STRUCTURAL ELEMENTS (I.E. CATCH BASINS, MANHOLES, VAULTS, ETC.) PER THE UTILITY PROVIDER'S REQUIREMENTS.VERIFY MIN. SEPARATION TOBOTTOM OF FACILITY, SEE NOTE 3PUBLIC WORKSDEPARTMENTAPPROVED:DATEGregg ZimmermanPublic Works AdministratorUNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)UTILITY CROSSINGS - BIORETENTION SECTIONSSTD. PLAN - 265.10DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA6388789/28/2018 | 9:45 AM PDT PLANPERVIOUS CONCRETE/POROUS ASPHALTCONCRETE FOOTING,DESIGNER TO SPECIFYROADWAYCURBSETBACK PERCITY STANDARDSUTILITY POLEPER CITYSTANDARDSUTILITY POLE PERCITY STANDARDSCONCRETE FOUNDATION,DESIGNER TO SPECIFYCURBROADWAYUTILITY POLE, PERCITY STANDARDSCONCRETE FOOTING,DESIGNER TO SPECIFYROADWAYBIORETENTIONFACILITY (TYP.)UTILITY POLE PER CITYSTANDARDSSCARIFIED AND UNCOMPACTEDSUBGRADE FOR INFILTRATINGFACILITIES, SEE NOTE 1SET AT OR ABOVEDESIGN PONDINGELEVATIONEXPANSION JOINTEXPANSIONJOINT (TYP.)NOTES:1.AVOID COMPACTION OF EXISTING SUBGRADE BELOW INFILTRATINGPERMEABLE PAVEMENT OR BIORETENTION FACILITIES DURINGCONSTRUCTION.2.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.SETBACK PERCITY STANDARDSROADWAYCONCRETE FOOTING,DESIGNER TO SPECIFYEDGE TREATMENT, SEESTD. PLAN 262.20SECTION AEDGE TREATMENT, SEESTD. PLAN 262.20PLANSECTION BABUTILITY POLE AT PERVIOUSCONCRETE/POROUS ASPHALTUTILITY POLE AT BIORETENTION FACILITYPERMEABLEPAVEMENTPAVEMENT FLUSHWITH FOOTING, (TYP.)SCARIFIED ANDUNCOMPACTEDSUBGRADE FORINFILTRATINGFACILITIES, SEE NOTE 1PUBLIC WORKSDEPARTMENTAPPROVED:DATEGregg ZimmermanPublic Works AdministratorUNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)UTILITY CONFLICTS - UTILITY POLESSTD. PLAN - 265.20DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA6388789/28/2018 | 9:45 AM PDT CCTV INSPECTION SPECIFICATIONS STD. PLAN - 266.00 GENERAL NOTES: 1.ALL NEWLY-INSTALLED AND NEWLY-REHABILITATED (PUBLIC AND PRIVATE) SANITARY SEWER AND STORM DRAIN MAIN LINES SHALL BE INSPECTED BY MEANS OF REMOTE CCTV. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY OF RENTON INSPECTOR ASSIGNED TO THE PROJECT PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS, AND/OR PAVEMENT. 2.THE CONTRACTOR SHALL PERFORM ALL CCTV INSPECTIONS IN ACCORDANCE WITH THE NATIONAL ASSOCIATION OF SEWER SERVICE COMPANIES (NASSCO) PIPELINE ASSESSMENT CERTIFICATION PROGRAM (PACP). 3.ALL CCTV OPERATORS SHALL HAVE CURRENT NASSCO PACP CERTIFICATION. 4.CCTV INSPECTIONS SHALL BE RECORDED IN A GRANITENET COMPATIBLE FORMAT DATABASE USING THE LATEST SOFTWARE VERSION AND SUBMITTED WITH ELECTRONIC LINKS BETWEEN THE DATA AND THE VIDEO ON AN EXTERNAL HDD, DVD, OR FLASH DRIVE. 5.ALL CCTV INSPECTION REPORTS SHALL BE WITHIN +/- TWO (2) FEET OF THE MEASURED LINEAR FOOTAGE BETWEEN MANHOLES ALONG THE EXISTING PIPELINE CENTERLINE FROM THE START OF PIPE TO END OF PIPE. 6.ALL OWNER AND PACP REQUIRED HEADER INFORMATION MUST BE FULLY AND ACCURATELY ENTERED ON ALL CCTV REPORTS. WORK NOT FOLLOWING THESE SPECIFICATIONS WILL BE REJECTED AND THE CONTRACTOR SHALL BE REQUIRED TO RE-CCTV THE WORK. 7.THE DOCUMENTATION OF THE WORK SHALL CONSIST OF PACP CCTV REPORTS, PACP DATABASE, LOGS, ELECTRONIC REPORTS, ETC. NOTING IMPORTANT FEATURES ENCOUNTERED DURING THE INSPECTION. THE SPEED OF TRAVEL SHALL BE SLOW ENOUGH TO INSPECT EACH PIPE JOINT, TEE CONNECTION, STRUCTURAL DETERIORATION, INFILTRATION AND INFLOW SOURCES, AND DEPOSITS, BUT SHOULD NOT, AT ANY TIME, BE FASTER THAN 30 FEET PER MINUTE, EXCEPT AS NOTED OTHERWISE IN THIS DOCUMENT. 8.THE CAMERA MUST BE CENTERED IN THE PIPE TO PROVIDE ACCURATE DISTANCE MEASUREMENTS TO PROVIDE LOCATIONS OF FEATURES IN THE SEWER AND THESE FOOTAGE MEASUREMENTS SHALL BE DISPLAYED AND DOCUMENTED ON THE VIDEO. ALL PACP OBSERVATIONS SHALL BE IDENTIFIED BY AUDIO AND ON A PACP LOG. ALL VIDEO MUST BE CONTINUOUSLY METERED FROM MANHOLE TO MANHOLE. ALL VIDEO RECORDING SHALL BE CONTINUOUS FROM STRUCTURE TO STRUCTURE WITH NO "PAUSING" OF THE VIDEO RECORDING DURING EACH PIPELINE INSPECTION. THE PIPE SHALL BE CLEANED PRIOR TO THE CCTV INSPECTION TO ENSURE ALL DEFECTS, FEATURE, AND OBSERVATIONS ARE SEEN AND LOGGED. 9.JUST PRIOR TO BEGINNING THE CCTV INSPECTION, WHILE THE CCTV CAMERA IS IN PLACE AND RECORDING, WATER (CONTAINING DYE) SHALL BE INTRODUCED INTO THE UPSTREAM MANHOLE OF EACH PIPE SEGMENT UNTIL IT IS OBSERVED AND RECORDED FLOWING PAST THE CAMERA'S FIELD OF VISION IN ITS ENTIRETY. 10.THE CCTV CAMERA SHALL HAVE A WATER-LEVEL MEASURING DEVICE (BALL, CYLINDER, ETC.) ATTACHED THAT HAS 1/4" MARKINGS TO SHOW THE DEPTH OF WATER IN THE PIPE DURING THE CCTV INSPECTION. 11.ALL MANHOLES SHALL BE CHANNELED AND COATED PRIOR TO CCTV INSPECTION. 12.PER CITY OF RENTON SPECIFICATION 7-08.3(2)B, SEWER AND STORM DRAIN PIPELINE SHALL HAVE NO MORE THAN 1/2" OF PONDING TO BE CONSIDERED ACCEPTABLE. PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT SURFACE WATER STANDARD PLAN NOTES (1 OF 2) STD. PLAN - 267.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2.THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3.ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4.APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5.A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6.THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANT'S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS-BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7.VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8.ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. 9.OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10.ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11.ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND 220.20. 13.STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE. 14.ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT-LOCKING LIDS PER THE CITY STANDARD PLAN 204.10, 204.20, 204.30, 204.40, AND 204.50. STRUCTURES SHALL HAVE: ·RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. ·ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. ·ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15.BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16.LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17.ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT SURFACE WATER STANDARD PLAN NOTES (2 OF 2) STD. PLAN - 267.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartin Pastucha Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18.ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: ·4 - 8 INCH ROCK / 40 - 70% PASSING; ·2 - 4 INCH ROCK / 30 - 40% PASSING; AND ·LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 19.FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON-SITE BMPS. 20.THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT-LOCKING LID MARKED "STORM” OR "DRAIN" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 21.ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22.ALL NEWLY-INSTALLED AND NEWLY-REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/OR PAVEMENT. 23.ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24.FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 25.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26.ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27.PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). 28.PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON-SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 29.CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30.MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 31.CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. SURFACE WATER STANDARD PLAN NOTES: DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT EROSION AND SEDIMENT CONTROL STANDARD PLAN NOTES STD. PLAN - 268.00 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2.THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT. 3.THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST-PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4.THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5.STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK-OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6.WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF-SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON-SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7.ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON-SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON-SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8.ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9.THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10.APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11.ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13.WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14.ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15.THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16.BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17.AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT-LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18.ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 19.AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON-SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20.PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21.PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT-LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON-SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22.ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS-OF-WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT