HomeMy WebLinkAbout204.10NOTES:
BOLT-DOWN SLOT DETAIL
SEE NOTE 1
SECTION A
TOP
SECTION B
SECTION C
1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES,
GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED.
PROVIDE TWO HOLES IN THE FRAME THAT ARE
VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS.
THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN
HEAD CAP SCREW BY BEING TAPPED, OR OTHER
APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES
VARIES BY MANUFACTURER.
2.ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN
LIEU OF THE RIB DESIGN.
3.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR
ADDITIONAL REQUIREMENTS.
4.FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD
PLAN 204.00.
24"
1 1/2"
3"
R26", SEE NOTE 2
BOLT-DOWN SLOT,
SEE DETAIL AND
NOTE 12 1/2" DIA. HOLE
1 5/8" MAX.
4 3/4"1 1/2"
3"
R39", SEE NOTE 2
1 1/2"
1/2" DIA. HANDLE
3/4" DIA. HOLE
5/8"
3/4"
4"
3 1/2"
5"
1/2"
3/4"
1 1/4"
5/8"A CB20"
ISOMETRIC
PUBLIC WORKS
DEPARTMENT
APPROVED:
DATEGregg Zimmerman
Public Works Administrator
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
RECTANGULAR SOLID METAL COVER
STD. PLAN - 204.10