WATER PLAN GENERAL NOTES Standard Plan Na. 300
1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS
STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS
AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION
15 IN PROGRESS. A PRE-CONSMUC nON ODNFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR
AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION.
2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING, CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL
CALL 1-800-424-5555 TO VERIFY UTIUTY LOCATIONS BEFORE BEGINNING EXCAVATION.
3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS. SHALL BE NEW AND UNDAMAGED, AND
"CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRK)R TO BRINGING ANY
MATERIALS ON -SITE.
4, ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C
104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FrMhlGS SHALL BE CLASS 2%AS
PER ANSI/AWWA C110fA21.104rwL ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE TYPE,
POLYETHYLENE PLASTIC PER AWWA CIM STANDARDS,
S. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS
AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE E0 INCHES.
ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION- WHERE UTILITY CONFLICTS OCCUR,
THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER.
PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH
BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST
METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS AND AS PERCENT MDD IN UNPAVED
AREAS, ALL PIPE ZONE COMPACTION SHALL BE 95 MDD.
6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF
RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS
AND BASE OF HYDRANTS. MEGA-LLIGS (OR SIMILAR PRODUCT) MAYBE REQUIRED ON ALLMECHANICALJOINTS IN ADDITION TO
CONCRETE BLOCKING.
7. ALLNEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED,
DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE
SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR, THE CONTRACTOR SHALL SUPPLY, INSTALL AND REPAM PLUGS,
CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FORTErnNG` AND PURITY ACCEPTANCE. NO
CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE MAN EiGSTING MAIN UNTIL
THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING.
S. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING
PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING
THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED,
AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR.
9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING
TRAYS PRIOR TO MAKINGS CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL E)MOSE THE EIASTINGx WATER
MAIN AND FrMNGS AT THE ODNMECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR
THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERALS, AND PROVIDE SHORING AND
ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE
CONTRACTOR SHALL PROVIDE AND INSTALL BACT(FILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION.
STD. PLAN — 300.0
PT_TBLTC WORKS WATER PLAN GENERAL NOTES
DEPARTMENT
MARCH 2010
t 10 FT
EXISTING WATER LINE
TE`�TING DETAIL
EXISTING TEE, DEAD ENE) LINE, CAP OR PLUG
DO NOT DISTURB BLOCKING
NEW WATER LINT-
0
VERTICAL CROSS (MJYFL) FOR POLYPIGGING
1 —BLIND FLANGE ON TOP WITH 2"TAP & 2"PLUG
1 —BLIND FLANGE ON BOTTOM
1—PLUG(MJ) W/2"TAP & 2„ BLOW—OV
TEMP. BLOCK
FINAL CONNECTION DETAIL
NEW WATER LINE
EXIST. WATER LINE
Q
AFTER ALL TESTING, CLEANING BY POLYPIG AND DISINFECTION,
REMOVE TEMP. BLOCK & ULOW--OFF & CONNECT
TO EXISTING WATER LINE WITH SLEEVE (MJ)
AND D.I. SPOOLS
FINAL CONNECTION BY CITY FORCES
STD. PLAN — 300.5
* + PUBLIC WORKS CONNECTION TO WATER MAIN
DEPARTMENT EXISTING TEE OR END LINE CAP
MARCH 2010
TEN W
Transportation Engineering NorthWest
Transportation Planning I Design I Traffic Impact & Operations
11400 SE 8th Street, Suite 200, Bellevue, WA 98004
Office (425) 889-6747
Project Contact: Elyse Stemmler, P.E.
Phone: 425-250-5004
COUGH LINPORTERLUNDEEN
STRUCTURAL CIVIL SEISMIC ENGINEERING
801 SECOND AVENUE, SUITE 900
SEATTLE, WA 98104
(206) 343-0460
www.cplinc.com
NO.
RECORD DRAWINGS
REVISION
TEMPORARY 2" GALVANIZED PIPE
AND 2" GATE VALVE
FINISHED GRADE ELEVATION
INSTALL 2" PLUG ON TOP BLIND FLANGE
AFTER REMOVAL OF POLYPIG
3 FT MIN. COVER (14-INCH DIAMETER AND UNDER)
4 FT MIN. COVER (12-INCH DIAMETER AND OVER)
1
NEW WATER MAIN POLYPIG
VERTICAL CROSS FOR POLYPIGGING STATION:
SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF AWN LINE
VERTICAL CROSS (Md X FL)
ONF RUND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW —OFF ASSEMBLY
(REIkOVE BLOW —OFF ASSEMBLY AND INSTALL 2" PLUG AFTER REMOVAL OF CLEANING "POLY —PIG-)
ONE BLIND FLANGE ON 6DTT0M OF CROSS
ONE PLUG (MJ) ON END OF CROSS
CONCRETE BLOCKING
ALL DEBRIS AND POLYPICS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE
DISINFECTION DF NEW WATER MAIN
STD, PLAN — 300.6
PIJ$WC WORKS POLY PIG STATION FOR CLEANING OF
DEPARTMENT VVATEIR MAINS
MARCH 2O10
FIRE HYDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-51IG OR
COMPRESSION TYPE SUCH AS CLO►V MEDALLION; M & H 929, MUELLM
SUPER CENTURION 200, AMD WATEROUS PACER MATH 6" MECHANICAL
JOINT INLET w1TH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2"
HOSE CONNECTIONS NATIONAL STANDARD THREADS. +4' PUMPER
CONNEC71ON CITY OF SEATTLE THREADS WITH A S70RZ ADAPTOR.
4-875" SEATTLE THREAD X 5' STORZ, ATTACHED WITH 1/8" STAENLESS
STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO
BE PAINTED WITH TWO COATS CF PAINT_ KECLLY-MOORE/PRESI=RVATIVE
PAINT No, 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR
APPROVED EQUAL. PUMPER CONNECTION TO FACE ROADWAY OR AS
DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO
BE USED IF REQUIRED.
CONCRFTF
THRUST BLOCK
16" x B" x 4" MININUM
CONCRETE BEARING
BLOCK UNDER HYDRANT
win
CUT
MIN. 18' TO 20" 5FHIND RACK OF
CURB OR 12" BEHIND BACK OF
SIDEWALK THAT IS ADJACENT TO
CURP
4,575" x 5' STURZ
5'xTx6" THICK CONCRETE PAD AROUND
HYDRANT, FINISH TO MATCH SIDEWALK.
EXPANSION JOINT AT
BACK OF SIDEWALK
--CONCRETE SIDEWALK
f DR PLAN71NC STRIP
35" MIN
COVER
TWO-PIECE CAST IRON VALVE BOX WITH LUG
TYPE COVER- EQUAL TO OLYMPIC FOUNDRY CO.
STANDARD 8" TOP SECTION WITH REGULAR BASE
SECTION LENGTH TO FIT, VALVE NUT IXTENS1411
AS REQUIRED -
RAISED PAVEMENT MARKER TYPE 88-A
Sl1MSONITE TWO-WAY BLUE REFLECTIVE
CONCRETE BLOCKING
- MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET.
6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT
6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT
2-3/+4" COR-TEN STEEL TIE RODS.
1/2 YARD OF 1-1/4" WASHED DRAIN ROCK
V ABOVE BOOT FLANGE- PLACE 8 MIL
POLYETHYLENE FILM AROUND TOP AND SIDES OF
GRAVEL.
E HYDRANT ASSEMBLY
LEVEL ALL GRIJUND
MIN 3' RADIUS
6" CONCRETE PAD
ONE MAN ROCK -
1
6�
LEVEL AL(, GROUND
MIN 3' RADIUS
6" CONCRETE PAD
FILL
HYDRANT LOCATION IN CUT OR FILL
PUBLIC WORKS FIRE HYDRANT ASSEMBLY STD PLAN — 310.1
+ ; DEPARTMENT
MARCH 2O10
SURVEYED:
TRS
DESIGNED:
RAG
DRAWN:
PRW
CHECKED:
BSB
BY DATE APPR APPROVED:
TBB
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CONSTRUCTION RECORD DRAWING
This construction record drawing is a copy of a cad file prepared by
COUGHLIN PORTER LUNDEEN and has been edited to reflect field
verified invert and rim elevations of the storm, sanitary sewer and water
main systems. Field verified invert and rim elevations were obtained by
KLB CONSTRUCTION IN JUNE 2022
The on -site private storm drainage facilities and public/private water and
sewer systems were installed in accordance with the approved plans and
the documented field revisions and function as intended.
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
Aoutoik
CITY OF
l*] RENTON
VAw
Planning/Building/Public Works Dept.
W-406802
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
PARK AVENUE NORTH EXTENSION
RENTON, WASHINGTON
UTILITY DETAILS
co
N
N
O
O
T
All
N
00
O
CD
O
O
I
T
I�
n
Z
rO
V )
Z
w
X
w
W
a
i
a
O
DATE:
04/30/2021
FlELDBOOK:
PAGE:
DRAWING NO:
C-310
. A
SHEET: 1 7 OF: 30