HomeMy WebLinkAboutEx 13_Tree Retention Plan.pdfDUVALL AVE. NE CHELAN AVE. NE NE 12TH ST.WETLAND TREE DENSITY CALCULATIONS AS PER THE CITY OF RENTON TREE DENSITY REQUIREMENT (RMC 4-4-130.H.1), THE REQUIRED MINIMUM TREE DENSITY IS 2 SIGNIFICANT TREES PER 5,000 SF. PROJECT SITE: 484,329 SF PROJECT TREE CREDITS REQUIRED (484329 / 5000): 97 PROJECT TREE CREDITS PROVIDED (18 EX. SIGNIF. TREES TO REMAIN + 114 REPLACEMENT TREES): 132 (SYMBOLS SHOWN AT 1"=20'-0" SCALE)TREE SCHEDULE DESCRIPTIONSYMBOL EXISTING TREES EXISTING LANDMARK CONIFEROUS TREE TO BE REMOVED (DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY) EXISTING LANDMARK DECIDUOUS TREE TO BE REMOVED (DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY) EXISTING EVERGREEN TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN EXISTING NON SIGNIFICANT CONIFEROUS TREE TO BE REMOVED (DETERMINATION OF SIGNIFICANCE BASED ON SIZE) EXISTING NON SIGNIFICANT DECIDUOUS TREE TO BE REMOVED (DETERMINATION OF SIGNIFICANCE BASED ON SIZE) TREE RETENTION CALCULATIONS AS PER THE CITY OF RENTON TREE RETENTION REQUIREMENT (RMC 4-4-130.H.1), THE PERCENTAGE OF TREES TO BE RETAINED IS AT LEAST 30% OF THE SIGNIFICANT TREES IN R-8 ZONES. TOTAL # SIGNIFICANT TREES (OVER 6" DIAMETER, OR ALDER /COTTONWOOD AT LEAST 8" DIA.): 499 TOTAL # EXCLUDED TREES (TREES IN CRITICAL AREAS / BUFFERS & PROPOSED PUBLIC STREETS): 228 SUBTOTAL TREES TO BE COUNTED (499 - 228): 271 REQUIRED # TO BE RETAINED (271 * 0.3): (81.3) 82 TOTAL # SIGNIFICANT TREES PROPOSED TO BE RETAINED: 18 PERCENTAGE OF TREES TO REMAIN (18 / 271): (6.66) 7% # REQUIRED REPLACEMENT INCHES (81.3 - 18 * 12): (759.6) 760 # REPLACEMENT TREES REQUIRED (MIN. 2" CALIPER TREES REQUIRED FOR REPLACEMENT) (759.6 / 2): (379.8) 380 30" EVG 30" DEC 30" DEC 30" EVG 5" DEC 5" EVG EXISTING SIGNIFICANT CONIFEROUS TREE TO BE REMOVED (DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY) EXISTING SIGNIFICANT DECIDUOUS TREE TO BE REMOVED (DETERMINATION OF SIGNIFICANCE BASED ON SURVEY SIZE ONLY)8" DEC 8" EVG REPLACEMENT TREES MIN. 2" CAL. DECIDUOUS REPLACEMENT TREE MIN. 6' HT. EVERGREEN REPLACEMENT TREE EXCLUDED SITE AREA - CRITICAL AREA (WETLAND) AND 100' BUFFER QTY 127,685 SF 9 9 29 5 204 67 15 22 82 52 NON SIGNIFICANT TREES TO BE REMOVED SUBTOTAL 37 SIGNIFICANT TREES TO BE REMOVED SUBTOTAL 271 LANDMARK TREES TO BE REMOVED SUBTOTAL 34 EXISTING TREES TO REMAIN SUBTOTAL 18 1.SEE CIVIL GRADING PLANS FOR TREE PROTECTION FENCING. ALL TREE RETENTION, PROTECTION AND CLEARING ACTIVITIES SHALL BE IN ACCORDANCE WITH RENTON MUNICIPAL CODE (RMC) 4-4-130 TREE RETENTION AND LAND CLEARING REGULATIONS. 2.PRIOR TO DEVELOPMENT ACTIVITIES, THE CONTRACTOR SHALL PROVIDE TREE PROTECTION MEASURES IN ACCORDANCE WITH RMC 4 4 130H FOR ALL EXISTING TREES SHOWN TO BE SAVED. 3.A CERTIFIED ARBORIST OR LANDSCAPE ARCHITECT SHALL MONITOR THE CONSTRUCTION ACTIVITIES THAT ARE NECESSARY WITHIN THE TREE DRIPLINES. 4.WRITTEN NEED FOR REMOVAL OR REVISED LANDSCAPE AND CLEARING/ GRADING PLANS SHALL BE REVIEWED AND APPROVED BY CURRENT PLANNING PROJECT MANAGER PRIOR TO CONSTRUCTION PERMIT APPROVAL. REPLACEMENT TREE SUBTOTAL 114 *TREES IN PROPOSED PUBLIC STREETS -20 TREE RETENTION NOTES IN COMPLIANCE WITH CITY OF RENTON STANDARDS ANDR E W J R ASM U S SENNO. 739 EXP.6 /2 6 /2021STATE O F W A SHI N GTONLANDS C AP E A R C H ITECT0' SCALE:N200'100'50'25' 1"=50'-0" NEW ELEMENTARY SCHOOL #16 CHELAN AVE NE RENTON, WA 98059 TREE RETENTION OVERALL PLAN NOTE: REFER TO L0.1 FOR TREE RETENTION WORKSHEET AND TREE PROTECTION DETAIL. IN COMPLIANCE WITH CITY OF RENTON STANDARDS ANDR E W J R ASM U S SENNO. 739 EXP.6 /2 6 /2021STATE O F W A SHI N GTONLANDS C AP E A R C H ITECTNEW ELEMENTARY SCHOOL #16 CHELAN AVE NE RENTON, WA 98059 TREE RETENTION WORKSHEET & DETAIL TREE PROTECTION NOTES: EXISTING TREE INDICATED TO SAVE OR POTENTIALLY TO SAVE. 1. A 6-FOOT HIGH TEMPORARY CHAIN LINK FENCE MUST BE PLACED WHERE SHOWN ON PLANS A MINIMUM OF FOUR BUSINESS DAYS PRIOR TO THE COMMENCEMENT OF WORK OR SITE DEMOLITION. VERIFY LOCATIONS WITH CIVIL. NOTIFY THE CLEARING AND GRADING INSPECTOR TO GET BOTH THE INSPECTION AND WRITTEN APPROVAL OF FLAGGED TREES AND TEMPORARY PROTECTION FENCING AROUND TREES TO BE SAVED PER THE APPROVED PLANS. 2. NO STOCKPILING OF MATERIAL AND NO VEHICULAR TRAFFIC ARE ALLOWED WITHIN THE LIMITS OF THE TEMPORARY FENCING. LIMIT INTRUSION INTO TREE DRIP ZONES WHEN POSSIBLE. FILLING, EXCAVATING, AND CLEARING WITHIN FENCED AREAS MUST BE ACCOMPLISHED BY HAND METHODS ONLY. 3. ROOTS OF TREES TO BE SAVED WHICH ARE DAMAGED DURING CONSTRUCTION WILL BE TREATED IN THE FOLLOWING WAY: FOR DAMAGED ROOTS OVER 1'' IN DIAMETER, MAKE A CLEAN, STRAIGHT CUT TO REMOVE THE DAMAGED PORTION OF THE ROOT. ALL EXPOSED ROOTS WILL BE TEMPORARILY COVERED WITH DAMP BURLAP OR WOOD SHAVING TO PREVENT DRYING AND COVERED WITH EARTH AS SOON AS POSSIBLE. 4. PER RMC 4-4-130-H.9.f, ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF THREE INCHES (3") OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. RESTRICTIONS: TREES TO BE PRESERVED SHALL BE DESIGNATED IN ACCORDANCE WITH APPROVED TREE PRESERVATION PLAN ON FILE WITH THE CITY OF RENTON. DESIGNATED TREES WHICH ARE DAMAGED OR DESTROYED SHALL BE REPLACED IN ACCORDANCE WITH RMC 4-4-130 TREE RETENTION AND LAND CLEARING REGULATIONS, OR AS HEREAFTER AMENDED. TREE PROTECTION DETAIL 16'-0'' CHAIN LINK ORSAFETY FENCING4' ORANGE LAMINAR