Loading...
HomeMy WebLinkAboutMFP21003305.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP21003305 IVR Number: 21003305 Permit Information Permit Name: Verizon - MCI Address/Location:06/14/2021Application Date:0886610060Parcel Number: 635 PARK AVE N Permit Type:08/05/2021Issue Date:Franchise Permit Work Class:08/05/2022Expiration Date:Major Utility Job Number: 1807BDIO.75_UG_REN_92521Franchise Type:Telephone Description: Pull 3831 LF of fiber through existing conduit. Contacts Name Address PhoneTypeBilling HOLLY NORTH MGC TECHNICAL CONSTULTING, INC 8521 154th Ave NE REDMOND, WA 98052 B: (206) 618-0651Applicant Henson Smith Mastec Network Solutions Inc Applicant Matthew Sapp Verizon - MCI Contact MasTec_Rep MasTec Contact Louise Popelka Verizon MCI Buisness 3245 158th Ave SE Bellevue, WA 98008 B: (425) 240-0238Contact Mastec Network Solutions Inc 22257 68th Avenue S Kent, WA 98032 Contractor Business License Number: 38949Construction Contractor: MASTENS876KN Electrical Contractor: MASTENS863JS Amy Ledvina Verizon - MCImetro 3245 158 Ave SE Bellevue, WA 98008 H: (425) 505-5651Specialized Billing X General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date MCIMETRO ACCESS TRANSMISSION SERVICES CORP. 1807BDIO.75_UG_REN_92521 Henson Smith 425.287.8701 henson.smith@mastec.com 635 PARK AVE N CENTRAL RENTON TO TUKWILA GATEWAY PULL (1) 3831 LF OF FIBER THROUGH EXISTING CONDUIT MASTEC NORTH AMERICA, INC.425.287.8701 MASTENA991KJ 51687 06/10/21 MFP21003305 Scott Warlick This permit is for Major construction work in the ROW and will be billed at an additional $60/HR for inspections. After hours and weekend work will be billed at $125/HR 8/5/2021 DEPARTMENT OF PUBLIC WORKS Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 1 of 2 | Published: 11/25/2019 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN (TCP) APPLICATION Published: 11/25/2019 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. TO THE APPLICANT: Submit the TCP application form and required submittal documents to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address. The following items, electronic copies preferred, are all required for submittal of the TCP Application: 1.☐ A copy of the Traffic Control Plan (TCP) Application form. 2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall: ☐Include map(s) showing the location of the project and work area. ☐Be legible lettering and clear, contrasting, symbols of viewing or printing. ☐Must indicate street names, and north arrow and scale. ☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. ☐Types of plans required: ☐Work hour plan – show all mobility impacts during construction hours. ☐Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. ☐Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. ☐Pedestrian access/detour plan, if applicable. Project Name: ______________________________________________ Permit #: _____________________ Project Address: ____________________________________________________________________________ Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Description of Work, Work Schedule, Equipment Used: _____________________________________________ ___________________________________________________________________________________________ ___________________________________________________________________________________________ Construction Company: ________________________________________ Phone/Cell: (_____) _____-________ Applicant Name: _________________________________ Email: ______________________________________ Business Address: _________________________________ City/State: __________________ Zip: __________ Approved By: _______________________________________________ Date: ________________________ Transportation Operations Engineering 1807BDIO.75_UG_REN_92521 635 PARK AVE N Monday Friday 8:00am 3:00pm PULL (1) 3831 LF OF FIBER THROUGH EXISTING CONDUIT MasTec North America 425 287 8701 Henson Smith henson.smith@mastec.com 151 Stewart Rd SW Pacific, WA 98047 MFP21003305 Scott Warlick CED 8/5/2021 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 2 | Published: 11/25/2019 APPLICANT AGREES TO ALL THE FOLLOWING: •TCP must be approved prior to commencing the work, and all permit conditions shall be met. •Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. •Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. •The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of traffic. This includes set up within the traveled way or immediately adjacent to the roadway. •Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures. •Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. •TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT) and all traffic regulations of the City of Renton and Revised Code of Washington (RCW). •Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Applicant’s agents and employees. •The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay for legal counsel chosen by the City to defend against same. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. •Approved Temporary TCP must be at the work site during work hours. •Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: •Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. •Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. •The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site. •Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street; 425-430-7423). _______________________________ _______________________________ _______________________ Applicant’s Signature Print Name Date Henson Smith 06/10/21 MCImetroACCESS TRANSMISSION SERVICES, CORPOUTSIDE PLANT CONSTRUCTIONENGINEERING SERVICESSEFNCOCOMMUNICATIONSMCI PERMIT NUMBER: 1807BDIO.75_UG_REN_92521SITE SPAN NFID: 1807BDIO.75CAPITAL PROJECT: 072443-001CENTRAL RENTON TO TUKWILA GATEWAYRENTON, WASHINGTONUNDERGROUND FIBER INSTALLATIONRIGHT-OF-WAY CONSTRUCTION PERMITPULL (1) 3831' OF FIBER THROUGH EXISTINGCONDUITMFP21003305This permit is for Major construction work in the ROW and will be billed at an additional$60/HR for inspections. After hours and weekend work will be billed at $125/HR © 2021 Microsoft Corporation © 2021 TomTom HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSVICINITY MAPBEGINENDSTA. 00+00STA.40+34635PARK AVE N251SUNSET BLVD NSHEET INDEX01COVER SHEET02VICINITY MAP, CONTACTS & SHEET INDEX03GENERAL NOTES04LEGEND05SHEET OVERVIEW06-15SITE PLAN15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021REN, UNDERGROUND FIBER INSTALLATION02N/ASEE SCALENCONTACTSJURISDICTIONOWNERSNAME OF FIRM: MASTEC NORTH AMERICAENGINEERING MANAGER: GERALD LUKEPHONE: 503-206-1280EMAIL: GERALD.LUKE@MASTEC.COMENGINEERING CONTRACTORCITY OF RENTONPHONE: 425-430-64001055 S GRADY WAYRENTON, WA 98057NAME OF FIRM: MCI METRO ACCESS TRANSMISSION SERVICES, CORP.PROJECT ENGINEER: BRAD LANDISPHONE: 425-229-3123EMAIL: BRAD.LANDIS@VERIZON.COMCONSTRUCTION CONTRACTORCONTACTSNAME OF FIRM: MASTEC NORTH AMERICACONSTRUCTION MANAGER: CASEY CHRISTLIEBPHONE: 509-823-0965EMAIL: CASEY.CHRISTLIEB@MASTEC.COMNAME OF FIRM: MASTEC NORTH AMERICAPERMITTING MANAGER: HENSON SMITHPHONE: 425-287-8701EMAIL: HENSON.SMITH@MASTEC.COMPERMITTING CONTRACTORFeet06001200MFP21003305 HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSGENERAL NOTES15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021REN, UNDERGROUND FIBER INSTALLATION03N/AN/ATHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP21003305 HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONS15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_9252104DH02/26/2021REN, UNDERGROUND FIBER INSTALLATIONN/AN/ALEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERELECTRICALRAILROADRIGHT OF WAYSIDEWALKCENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILFENCEINNERDUCT1_4" HDPE2_2" PVC1_4" PVC1_2" PVCSDSDWWSSSSGGEETTR/WLIPSWEOPFOCRWRW1-4'' PVC1-4'' PVC1-2'' PVC1-2'' PVC1-4'' HDPE2-2'' PVC2-2'' PVC2_2" HDPE1_2" HDPETRENCHEXISTING AERIAL STRANDDIRECTIONAL BORE2-2'' HDPEDBDB1-2'' HDPEAAPROPOSED AERIAL STRAND AAEXISTING UNDERGROUND MCIPROPOSEDEXISTING VERIZONBASE LAYERSEXISTING UTILITIESEXISTING UTILITIES SYMBOLS POWER HANDHOLEPOWER MANHOLEPOWER CABINETSTREET LIGHT HANDHOLEPOWER SIDEWALK GUY SEWER CLEANOUTSTORM CATCH BASIN STORM MANHOLEWATER VALVEWATER METERTELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALPOWER VAULTSTREET LIGHT POLETRAFFIC SIGNAL VAULTTRAFFIC SIGNAL HANDHOLESIGN POSTPARKING METERCATV MANHOLECATV HANDHOLEPOWER PEDESTALGAS METERTEST VALVETRAFFIC LOOP DETECTORCATV PEDESTALBOLLARDWATER MANHOLETRAFFIC SIGNAL POLEPOWER GUYTRAFFIC DETECTORADA RAMPPEDESTAL(UNKNOWN UTILITY)MANHOLECULVERTFIRE HYDRANTGAS VALVE(UNKNOWN UTILITY)POWER ANCHORPOWER POLESEWER MANHOLETELECOM POLETELECOM PEDESTALPROPOSED VAULTPROPOSED ANCHORPROPOSED GUYPROPOSED MANHOLEPROPOSED SIDEWALK ANCHOR & GUYPROPOSED SYMBOLS ADA RAMP COMPLIANCEPEXISTING MCI VAULTEXISTING MCI SPLICEEXISTING MCI ANCHOREXISTING MCI GUYEXISTING MCI MANHOLEEXISTING MCI SIDEWALK ANCHOR & GUYMHVLP=MHVLP=GAS TEST POINTGAS MANHOLEPOWER UNKNOWN STORM CLEANOUTSTORM DRAIN VALVESTORM DRAIN UNKNOWN WATER UNKNOWNWATER WELLWATER PUMPWATER VAULTWATER RESERVOIRPPPPPP?PSLSLTSTSTSTSTSTSCCCTTTP=??TTSSSCSDD?DCDWWWWWVW?WELLPUMPGGGTLTLSDSEWER CATCH BASIN SSWATER SAMPLING STATIONOTHER UNKNOWNSTORM ACCESS POINTSEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?SUB STATIONTRANSIT STOPSTORM DRAIN VAULT SDTREE PROPOSED RISEREXISTING MCI SYMBOLS POTHOLEBORE PITCA-MKRCABLE MARKERMFP21003305 © 2021 Microsoft Corporation © 2021 TomTom HORZ:VERT:SHEET OFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSNLOCATION OVERVIEWBEGINEND15REVISIONSDATE DESCRIPTION INITIAL OUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021REN, UNDERGROUND FIBER INSTALLATION05N/ASEE SCALEFeet0400800SHEET# 6SHEET# 7SHEET# 9SHEET# 10SHEET# 11SHEET# 15SHEET# 8SHEET# 13SHEET# 12SHEET# 14MFP21003305 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOC FOC FOC SWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW0+0088'56'28'24'MCIMCIMCIMCIMCIMCIMCIMCIVL HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONS1CONSTRUCTION NOTES2(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLE THROUGHEXISTING CONDUIT. CONTRACTORTO VERIFY CORRECT VAULT PRIORTO CONSTRUCTION.Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NMATCH LINE A-115REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION06 EXISTING MCI VAULT.635PARK AVE N1807BDIO.63_UG_REN_90314PARK AVE N Feet04080GENERAL NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDS12MFP21003305 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSW 01+0002+0003+0004+00TSLSLSLSLWMCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONS1CONSTRUCTION NOTES(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLE THROUGHEXISTING CONDUIT. CONTRACTORTO VERIFY CORRECT VAULT PRIORTO CONSTRUCTION.Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NMATCH LINE A15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION07635PARK AVE NPARK AVE N Feet04080GENERAL NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDS1MATCH LINE A-1MFP21003305 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSW SWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSW SW SW FOC FOC FOC FOC FOC FOC05+0006+0008+00SLSLHH?THHSLSL09+0010+00VLMCIMCIMCIMCIMCIMCIMCIMCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI07+00HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSCONSTRUCTION NOTESKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NMATCH LINE AMATCH LINE B 15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION08 618PARK AVE NPARK AVE N Feet04080GENERAL NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDS600PARK AVE NN 6TH ST11212EXISITING 30"x48" MCI VAULT.(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLETHROUGH EXISTING CONDUIT.CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TOCONSTRUCTION.MFP21003305 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOC FOCSWSWSWSWSWSWSWSWSWSWSWSWS W SW SW SWSWSWSWSWSWSWSW SW SW SW SW SWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SWSWSW SW SW SW SWSWSWSWSWSWSWSW11+0012+0013+0014+00MCI MCI MCI MCI MCI MCI MCI MCI MCIMCIMCIMCIMCIMCIHORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NMATCH LINE B 15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION09GARDEN AVE N Feet04080535N 6TH ST1601N 8TH STN 6TH STMATCH LINE C11CONSTRUCTION NOTES(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLETHROUGH EXISTING CONDUIT.CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TOCONSTRUCTION.GENERAL NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDSMFP21003305 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WSWSWSWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC SW SW SW SW SW SW SW SW SW SW SW SW SW SWSW S W FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC SW15+0016+0017+0018+00MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.N15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION10GARDEN AVE N Feet04080525GARDEN AVE NMATCH LINE D1CONSTRUCTION NOTES(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLETHROUGH EXISTING CONDUIT.CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TOCONSTRUCTION.GENERAL NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDS1MATCH LINE CMFP21003305 R/W R/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCVL19+0020+0021+0022+00MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI MCI HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.N15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION11GARDEN AVE N Feet04080420PARK AVE NMATCH LINE EGENERAL NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDS2MATCH LINE D1N 5TH ST1CONSTRUCTION NOTES2(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLE THROUGHEXISTING CONDUIT. CONTRACTORTO VERIFY CORRECT VAULT PRIORTO CONSTRUCTION.EXISTING 17"x30" MCI VAULT.*NO MCI LABEL ON LID.*MFP21003305 R/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOC FOC FOC FOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC SWSWSWSWSWSWSWSWSWSWSW SW SW SW SW SW SW SW SW SW SW SW SWSWSWSW FOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWFOCFOCFOCFOCFOCFOCFOC23+0024+0025+0026+0027+0028+00MCI MCIMCI MCI MCI MCI MCI MCI MCI MCI MCI VLMCIMCIMCIMCIMCIMCIMCIHORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NMATCH LINE F 15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION12GARDEN AVE N Feet04080420PARK AVE NGENERAL NOTES2MATCH LINE E1N 4TH ST1CONSTRUCTION NOTES2(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLE THROUGHEXISTING CONDUIT. CONTRACTORTO VERIFY CORRECT VAULT PRIORTO CONSTRUCTION.EXISTING 17"x30" MCI VAULTCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDS336PARK AVE N356GARDEN AVE N359MEADOW AVE N2MFP21003305 R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCFOCFOCFOCSWS WEOPEOPEOPEOPEOPEOPEOPEOPEOP FOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC SWSW SW SW SW SW SW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW FOCFOCFOCEOP EOP EOP EOP EOP EOP FOCFOCSWSWSWSWSW SW SW SW SW SWSWSWSWSWSWSWSWS W SWSWSWSW SWSWFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFO C FOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOC FOC FOCFOCFOCFOCFOCFOCSWSWVLMCIMCIMCIMCIMCIMCI29+0030+0031+003 2 + 0 0 3 3 + 0 0 MCIMCIMCIMCIMCIMCIMCIMCIMCIMCIMCIMCIMCIHORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NMATCH LINE G 15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION13MEADOW AVE N Feet040801407N 4TH STGENERAL NOTES21N 4TH ST1CONSTRUCTION NOTES2(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLE THROUGHEXISTING CONDUIT. CONTRACTORTO VERIFY CORRECT VAULT PRIORTO CONSTRUCTION.EXISTING 24"x36" MCI VAULTCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDSMATCH LINE F1409N 4TH ST350MEADOW AVE N344MEADOW AVE N340MEADOW AVE N2359FACTORY AVE N351FACTORY AVE N343FACTORY AVE NFACTORY AVE N FACTORY PL NMFP21003305 R/WR/WR/WR/WR/WR/WR/WR/WR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/WR/WR/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/W R/WR/WR/WR/WSWSWSWSWSWSWSWSWFOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWSWFOC FOC FOCFOCSWSWSWSWSWSWSWSWSWEOP EOP EOP EOPSWSWSWSWSWSWSWSWSWSWSWSW SW SW SWSW SWSWSWSWSWSWFOCFOCFOCFOCFOCFOCMCIMCIMCIMCIMCIMCIMCIMCIMCI34+0035+0036+00 HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.N15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION14Feet04080MATCH LINE HGENERAL NOTES1N MARION STCONSTRUCTION NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDSMATCH LINE G1530N MARION ST1515N MARION ST1532N MARION ST320FACTORY AVE N310FACTORY PL NFACTORY PL N1525N 4TH ST1655N 4TH ST1544N MARION ST325HOUSER WAY NHO U S E R W A Y N 1(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLETHROUGH EXISTING CONDUIT.CONTRACTOR TO VERIFYCORRECT VAULT PRIOR TOCONSTRUCTION.MFP21003305 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPSWSWSW SW SW SW SW SWSWSWSWSWSWSWSW SWSWSW SW FOC FOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSW SWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWEOPEOPEOPEOPEOPSW EOPEOPEOPEOPEOPFOCFOCFOCFOCFOCFOC FOC FOCFOCFOCFOCFOCFOCFOC FOCFOCEOP EOP EOP EOP EOPSWSWSWSWSWSWSWSWSWSWEOPSW SW SW SW SW SW SWSWSWSWSWSWFOCFOCFOCFOCFOCSW SWSWSW FOCFOCFOCMCIMCIMCIMCIMCIMCIVL37+00 41 + 0 0 40 + 0 0 HORZ:VERT:SHEETOFDATE:ENGINEER:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF MCI COMMUNICATION SERVICES, INC. BOTHBEING ISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.MCI METRO ACCESS TRANSMISSION SERVICES, CORP. SITE NAME:SCALELOCATION ADDRESS: MASTEC ID NUMBER:P.E. STAMPDRAWN BY:DATESEFNCOCOMMUNICATIONSKnow what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NMATCH LINE H15REVISIONSDATEDESCRIPTIONINITIALOUTSIDE PLANT CONSTRUCTION CENTRAL RENTON TO TUKWILA GATEWAY 635 PARK AVE N RENTON, WA 1807BDIO.75_UG_REN_92521DH02/26/2021SEE SCALEN/AREN, UNDERGROUND FIBER INSTALLATION15Feet04080GENERAL NOTESN 3RD STCONSTRUCTION NOTESCONTRACTOR TO CONFIRM ANDMAINTAIN CLEARANCE OF STRUCTURESREFER TO CITY OF RENTON TREEPROTECTION STANDARDSFACTORY PL NHO U S E R W A Y N N 3RD ST1212(1) 2" CONDUIT W/ (1) 288F & MULETAPE. PULL FIBER CABLE THROUGHEXISTING CONDUIT. CONTRACTORTO VERIFY CORRECT VAULT PRIORTO CONSTRUCTION.EXISTING 24"x36" MCI VAULTHO U S E R W A Y N 310FACTORY PL N315FACTORY PL N1526N 3RD ST1601N 8TH ST251SUNSET BLVD N1522N 3RD ST1516N 3RD ST1512N 3RD ST1513N 3RD ST1517N 3RD ST1521N 3RD ST1525N 3RD ST1531N 3RD STMFP21003305 PROJECT ID NUMBER 1807BDIO.75_UG_REN_92521 PERMITTING ENTITY PROJECT LOCATION SCOPE OF WORK: DRAWN BY: DATE: SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON 635 PARK AVE N JM 3/03/2021 1 6 TCS STAMP:1807BDIO.75_UG_ROW_92521COVER PAGETRAFFIC CONTROL PLANBUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) LENGTH (FEET) 25 30 35 40 45 50 55 60 65 70 155 200 250 305 360 425 495 570 645 730 MINIMUM SHOULDER TAPER LENGTH (L/3) (FEET) Shoulder Width Feet Posted Speed (mph) 10 25 30 35 40 45 50 55 60 65 70 40 40 40 60 60 90 90 90 120 150 130 170 150 190 200 8 160 170 190 240220 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. (1) All spacing may be adjusted to accommodate interchange ramps,at-grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. RURAL HIGHWAYS RURAL ROADS RURAL ROADS & URBAN ARTERIALS RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS URBAN STREETS ALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. 60/65 MPH 45/55 MPH 35/40 MPH 25/30 MPH 25 MPH OR LESS 800' SIGN SPACING=X (FEET) (1) 500' 350' 200' 100'(2) (2) FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR AS PER MUTCD) MINIMUM TAPER LENGTH (L) IN FEET Lane Width Feet Posted Speed (mph) 10 11 12 25 30 35 40 45 50 55 60 65 70 105 115 125 150 165 180 205 225 245 265 295 320 450 495 540 500 550 600 550 605 660 660 720 780 840 CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 30 20 80 60 40 TRAFFIC CONTROL PLAN: SHORT DURATION WORK ZONE FOR EXISTING UNDERGROUND CONDUIT INSTALLATION All Signs & Spacing to conform to the MUTCD & The City of RENTON Standard General Notes: 1. All signs and spacing shall conform to The MUTCD and WAC. 2. Priority passage through the work area for emergency vehicles vehicles shall be provided at all times. 3. Alert Metro Transit 5 days in advance 4. Protective vehicle recommended may be a work vehicle. 5. Devices should not encroach into adjacent lanes. 6. All signs min. 48 x 48 B/O unless otherwise specified. 7. Channelization devices are 28" reflective cones 8. All sign spacing may be adjusted to accommodate at-grade intersections and/or driveways. 9. A Traffic Control Supervisor is required for all work affecting ROW. TRAFFIC CONTROL PLAN COVER PAGE CONSTRUCTION CONTRACTOR: MASTEC CASEY CHRISTLIEB 509-823-0985 CASEY.CHRISTLIEB@ MASTEC.COM OUTSIDE PLANT ENGINEERING: MCI BRAD LANDIS 425-229-3123 BRAD.LANDIS@ VERIZON.COM ENGINEERING CONTRACTOR: MASTEC GERALD LUKE 503-206-1280 GERALD.LUKE@ MASTEC.COM PROJECT DESCRIPTION: PULL (1) 3951' OF FIBER THROUGH EXISTING CONDUIT. N 635 PARK AVE N 251 SUNSET BLVD N www.invarion.com MFP21003305 BOEING 10-18 635 PARK AVE N 10-18 PARKING GARAGE DR 627-677 GARDEN AVE N V 12' 30' PARK AVE N30MPH S 12'11' ROAD WORK AHEAD W20-1 W4-2 RIGHT LANECLOSEDAHEAD W20-5 200' 200' 200' 180' B PROJECT ID NUMBER 1807BDIO.75_UG_REN_92521 PERMITTING ENTITY PROJECT LOCATION SCOPE OF WORK: DRAWN BY: DATE: SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON 635 PARK AVE N JM 3/03/2021 2 6 TCS STAMP:1807BDIO.73_UG_ROW_92521RIGHT LANE CLOSURE SHEET 2 TCP IS FOR SHEET 6 OF 14 OF SITE WORK PLANS.TRAFFIC CONTROL PLANAll Signs & Spacing to conform to the MUTCD & The City of RENTON Standard Legend Arrowboard (Chevron) C-Curb Cone Spotter V Vault Work Area Work Truck MPH TAPER SIGN SPACING TAPER TAGENT SHIFT TAPER = 1/2 TAPER SHOULDER TAPER = 1/3 TAPER 30 180'200'20'40' MPH TAPER SIGN SPACING TAPER TAGENT 25 125'100'20'40' N TRAFFIC CONTROL PLAN: SHORT DURATION WORK ZONE FOR EXISTING UNDERGROUND CONDUIT INSTALLATION EXISTING VAULT PLACE ON NORTH WESTSIDE CORNER OF PARK AVE N & N 6TH ST FOR PEDESTRIAN DETOUR. SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(R) PLACE ON SOUTH WESTSIDE CORNER OF PARK AVE N & N 8TH ST FOR PEDESTRIAN DETOUR. SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(L) Plan Scale 1 : 600 (1'' = 50')1807BDIO.75_UG_ROW_92521www.invarion.com MFP21003305 20' 11' 11' 10' N 6TH ST 25MPH V GARDEN AVE N25MPH PARK AVE N30MPH 10' 30' ROADWORKAHEAD W20-1 ROAD WORK AHEAD W20-1 ROADWORKAHEAD W20-1 ROADWORKAHEAD W20-1 W4-2 RIGHT LANECLOSEDAHEAD W20-5 100'100'100'105'B SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(L) SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(R) S 535 N 6TH ST 618 PARK AVE N PROJECT ID NUMBER 1807BDIO.75_UG_REN_92521 PERMITTING ENTITY PROJECT LOCATION SCOPE OF WORK: DRAWN BY: DATE: SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON 635 PARK AVE N JM 3/03/2021 3 6 TCS STAMP:1807BDIO.73_UG_ROW_92521RIGHT LANE CLOSURE SHEET 3 TCP IS FOR SHEET 7 OF 14 OF SITE WORK PLANS.TRAFFIC CONTROL PLANAll Signs & Spacing to conform to the MUTCD & The City of RENTON Standard Legend Arrowboard (Chevron) C-Curb Cone Spotter Traffic Light V Vault Work Area Work Truck MPH TAPER SIGN SPACING TAPER TAGENT SHIFT TAPER = 1/2 TAPER SHOULDER TAPER = 1/3 TAPER 30 180'200'20'40' MPH TAPER SIGN SPACING TAPER TAGENT 25 105'100'20'40' N TRAFFIC CONTROL PLAN: SHORT DURATION WORK ZONE FOR EXISTING UNDERGROUND CONDUIT INSTALLATION EXISTING VAULT Plan Scale 1 : 600 (1'' = 50')1807BDIO.75_UG_ROW_92521www.invarion.com MFP21003305 N 5TH ST25MPH V 525 GARDEN AVE N 420 PARK AVE N 12' 30' 12'11'12' ROAD WORK AHEAD W20-1RIGHT LANECLOSED AHEAD W20-5 W1-4 KEEP RIGHT R4-7 KEEP RIGHT R4-7 ROAD WORKAHEAD W20-1 RIGHT LANECLOSEDAHEAD W20-5 W1-4 ROAD WORK AHEAD W20-1 LEFT LANECLOSEDAHEAD W20-5 W4-2 W4-119R 100' 100' 100' 100' 100' 100' 125' B 100'100'100' GARDEN AVE N25MPH S SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(L) PLACE ON NORTH WESTSIDE CORNER OF GARDEN AVE N & N 4TH ST FOR PEDESTRIAN DETOUR. SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(R) PLACE ON SOUTH WESTSIDE CORNER OF GARDEN AVE N & N 6TH ST FOR PEDESTRIAN DETOUR. SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(L) PROJECT ID NUMBER 1807BDIO.75_UG_REN_92521 PERMITTING ENTITY PROJECT LOCATION SCOPE OF WORK: DRAWN BY: DATE: SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON 635 PARK AVE N JM 3/03/2021 4 6 TCS STAMP:1807BDIO.73_UG_ROW_92521RIGHT LANE CLOSURE SHEET 4 TCP IS FOR SHEET 10 OF 14 OF SITE WORK PLANS.TRAFFIC CONTROL PLANAll Signs & Spacing to conform to the MUTCD & The City of RENTON Standard Legend Arrowboard (Chevron) Cone Spotter V Vault Work Area Work Truck MPH TAPER SIGN SPACING TAPER TAGENT SHIFT TAPER = 1/2 TAPER SHOULDER TAPER = 1/3 TAPER 30 180'200'20'40' MPH TAPER SIGN SPACING TAPER TAGENT 25 125'100'20'40' N TRAFFIC CONTROL PLAN: SHORT DURATION WORK ZONE FOR EXISTING UNDERGROUND CONDUIT INSTALLATION EXISTING VAULT Plan Scale 1 : 600 (1'' = 50')1807BDIO.75_UG_ROW_92521www.invarion.com MFP21003305 N 4TH ST25MPH V FACTORY PL N30MPH V GARDEN AVE N25MPH MEADOW AVE N25MPH 11'35' 11' 35' 11' 11' 11' 11' 11'11'22' 356 GARDEN AVE N 1411 N 4TH ST 351 FACTORY AVE N ROAD WORK AHEAD W20-1 ROAD WORKAHEAD W20-1 W4-2 W4-2 RIGHT LANECLOSEDAHEAD W20-5 RIGHT LANECLOSEDAHEAD W20-5 100' 100' 100' 115' B 100'110'100'115'B FACTORY AVE N25MPH 14' S S SIDEWALK CLOSED CROSS HERE R9-11a(R) SIDEWALK CLOSEDAHEAD CROSS HERE R9-11(L) R3-6R R3-6R PROJECT ID NUMBER 1807BDIO.75_UG_REN_92521 PERMITTING ENTITY PROJECT LOCATION SCOPE OF WORK: DRAWN BY: DATE: SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON 635 PARK AVE N JM 3/03/2021 5 6 TCS STAMP:1807BDIO.73_UG_ROW_92521RIGHT LANE CLOSURE SHEET 5 TCP IS FOR SHEET 11 & 12 OF 14 OF SITE WORK PLANS.TRAFFIC CONTROL PLANAll Signs & Spacing to conform to the MUTCD & The City of RENTON Standard Legend Arrowboard (Chevron) Cone Spotter Traffic Light V Vault Work Area Work Truck MPH TAPER SIGN SPACING TAPER TAGENT SHIFT TAPER = 1/2 TAPER SHOULDER TAPER = 1/3 TAPER 30 180'200'20'40' MPH TAPER SIGN SPACING TAPER TAGENT 25 115'100'20'40' N TRAFFIC CONTROL PLAN: SHORT DURATION WORK ZONE FOR EXISTING UNDERGROUND CONDUIT INSTALLATION EXISTING VAULT EXISTING VAULT SPOTTERS SHALL ASSIST PEDESTRIAN'S AROUND THE WORK AREA AT ALL TIMES. Plan Scale 1 : 600 (1'' = 50')1807BDIO.75_UG_ROW_92521www.invarion.com MFP21003305 V V FACTORY PL N30MPH HOUSER WAY N25MPH N 3RD ST25MPH 10' 35' 10' 50' 10'11'10'10' SUNSET BLVD N30MPH ROAD WORK AHEAD W20-1 ROADWORKAHEAD W20-1 ROAD WORK AHEAD W20-1 ROAD WORKAHEAD W20-1 ROADWORKAHEAD W20-1 S SHOULDERWORK W21-5 100' 100' 40' B S W4-2 LEFT LANE CLOSEDAHEAD W20-5 ROADWORK AHEAD W20-1 100' 100' 100' 105' B HOUSER WAY N25MPH SUNSET BLVD N30MPH OVERPASS INTERSTATE I-405 251 SUNSET BLVD N 1526 N 3RD ST 1531 N 3RD ST Plan Scale 1 : 600 (1'' = 50') PROJECT ID NUMBER 1807BDIO.75_UG_REN_92521 PERMITTING ENTITY PROJECT LOCATION SCOPE OF WORK: DRAWN BY: DATE: SHEET OFMCI METROACCESS TRANSMISSION SERVICES, CORP.PROJECT NAMERENTON 635 PARK AVE N JM 3/03/2021 6 6 TCS STAMP:1807BDIO.73_UG_ROW_92521LEFT & SHOULDER LANE CLOSURE SHEET 6 TCP IS FOR SHEET 14 OF 14 OF SITE WORK PLANS.TRAFFIC CONTROL PLANAll Signs & Spacing to conform to the MUTCD & The City of RENTON Standard Legend Arrowboard (Chevron) Cone Spotter Traffic Light V Vault Work Area Work Truck MPH TAPER SIGN SPACING TAPER TAGENT SHIFT TAPER = 1/2 TAPER SHOULDER TAPER = 1/3 TAPER 30 180'200'20'40' MPH TAPER SIGN SPACING TAPER TAGENT 25 115'100'20'40' N TRAFFIC CONTROL PLAN: SHORT DURATION WORK ZONE FOR EXISTING UNDERGROUND CONDUIT INSTALLATION EXISTING VAULT EXISTING VAULT SPOTTERS SHALL ASSIST PEDESTRIAN'S AROUND THE WORK AREA AT ALL TIMES.1807BDIO.75_UG_ROW_92521www.invarion.com MFP21003305