HomeMy WebLinkAboutR-404216BZ O Z W /rr /V ) O J O n C) �1 J U III Trapzilla`a' Grease Interceptor a, ATHERMACO'rTechnology TZ-160-ECA Specifications PRODUCT FEATURES Constructed Of corrosion resistant materials suitable for installation in virtually any location. Compact footprint. - - Outlet Pipe 03.5 in Baffle structure retains separated grease increasing retention [8.9 cm] efficiency of separator - Includes one ECA-TZ-29 Extension Collar for in -ground installation. r,c?1_i_ Included lid rated for foot -traffic only-11-11-17-0-41 4-4 T 1 SPECIFICATIONS 26. cn a a '� 27.5 in [ ] , 1_ [69.9 cm] Construction: Single -Piece Rotationally Molded 77 Polyethylene Exterior Tank with Inlet/=+-,-i-+-1-1-I- Outlet Inverts secured using Patented interior Radial Compression Ring Flow Rating: 35 gpm (2.21 Its) f Liquid Capacity- 27 gallons (102 I) 03.5 in Inlet Pipe -- Grease Capacity: 22.7 gallons (85.9 1) [8.9 cm] 167.71bs. (76.1 11 Solids Capacity: 8-3 gallons (31.4 1) Inlet/Outlet 3" (75 mm) Product Weight: 60lbs. (28 Kg) 10 in [25.4 cm] CLEARANCE FROM TOP OF TANK REQUIRED FOR LID REMOVAL 27•03 LID = -24&A-8- S u PcCE i {]} 29.4 in [74.6 cm] �i22 in 4 in [55.9 cm[10.1 cm] 7.5 in [19.1 cm] 8 in - NET CA .Cb FROM BOT. l [20.3 cm] NFT CA= FM IN OF SMIMRE = 24M INLET OF S7MTURE EL. = EL. _ •2ieCf- v 2"' VENT END VIEW OUTLET MAXIMUM 35 In COLLAR 51DE VIEW EXTENSION [88.9 cm] MAXIMUM (TRIMMED) COLLAR 27 In 27.5 in EXTENSION [69.9 cm] [68.6 cm] 019 in [48.3 cm] 10.5 1n [26.7 Cm] t I =21 c12019 Thermaco. Inc. • All rights reserved • PatentedJPatents Pending • Specifications subject to change without notice Thermaco, Inc. • PO Box 2548 • Asheboro. NC 27204.2548 • (336) 629.4651 • www.trapzilia.com BOT. 4.04 GREASE TRAP INTERCEPTOR #2 WX SERIES, EXPLOSION PROOF PUMP IN A W SERIES SIMPLEX BASIN E/One EQUALIZER MUSHROOM VENT (FACTORY DRILLED FIELD INSTALLED) TRAFFIC RATED LID "COD" LIFTING ROPE - (NYLON) DISCHARGE SLIDE FACE QUICK D15CONNECT EL. = -26W& LE-23.1810 SS DISCHARGE 1-1/4 FEMALE NPT (FACTORY INSTALLED) ANTI -SIPHON/ CHECK VALVE BOTTOM - 19.98 26.18 oc 4 DIAMETER CHOICES SERIES SIMPLEX 24 © 30 STATIONS 36 HEIGHT CHOICES COVER OVER DISCH CHOICES 'H' COD RANGE "COD" 60 ( 24 ) L 24 ❑ 66 (24-30) 30 72 (24-36 ❑ 36 ❑ 78 (24-42) ❑ 42 ❑ 84 (24-48) ❑ 48 ❑ 90 (24-54) ❑ 54 ❑ 96 (24-60) ❑ 60 ❑ 102 (24-66) ❑ 66 ❑ 108 (24-72) j7] 72 ❑ 114 (24-78) ❑ 78 ❑ 120 (24-84) ❑ 84 ❑ 126 (24-90) 90 ❑ 132 (24-96) ❑ 96 ❑ 138 (24-102) ❑ 102 ❑ 144 (24-108) ❑ 108 EJ (DIMENSIONS ARE IN INCHES) FLEXIBLE �-DISCHARGE HOSE u I � EPDM INLET GROMMET �- (FIELD INSTALLED) EL = Z3.LI2_ LE-2278 ALARM EL =� c Min FROM BOT. OF FC11i FROM BOT. OF m S=g7URE Q 1.40 MUMRE - 22.06 r b" INLET -2t-&* ` =r7 gcl LOCATION EL. = OFF VARIABLE 2to 17- 30' MIN CALCb BOT. OF 13, 32 gal RE 24 gal VOLUMES SHOWN ARE FOR 024 .D" FIBERGLASS TANK WITH ANTI -FLOAT FLANGE SEMI -POSITIVE DISPLACEMENT TYPE PUMP DIRECTLY DRIVEN BY 1 HP MOTOR SGS 03 3l 08 1/16 INLET CHOICES DR BY I CHK'D DATE ISSUE SCALE 4" DWV PIPE (4.50 OD) ❑1'°, 4" DR35 PIPE (4.22 OD) 6" DWV PIPE (6,63 OD) 6" DR35 PIPE (6.28 OD) ❑ SEWER SYSTEMS WX SERIES PUMP IN A SIMPLEX NOTE W SERIES STATION THE PUMP A55EMBLY IS LISTED BY ETL TO FACTORY MUTUAL (FM) STANDARDS FOR CLASS I, DIVISION I, GROUP D, THE LEVEL CONTROL NA0133P01 SYSTEM, INTEGRAL TO THE PUMP, IS INTRINSICALLY SAFE GRINDER PUMP DETAIL#1 NOT TO SCALE OFIrn Trapzilla"i Grease Interceptor I Mgt, ru ATIiERMACOTTechnology TZ-160-ECA Specifications NOTES 1, READ instruction manual included with system before installingioperating. 2. Unit requires 6" (15.24 cm) of clearance all the way around the lid from walls or other structures to allow for servicing. 3. Make piping connections with rubber "No Hub" connectors. 4. Keep outlet piping as straight as possible. Use only "sweep" connections. 5. Install vent on outlet piping. 6. If installing in conjunction with other Trapzilla products, include cleanout port before, after, and/or between each unit 7. Do not install "P" Trap on outlet connection of tank (unit already has internal gas trap). 8. Do not reduce pipe size on outlet piping 9. Do not pressure test unit. Equipment must be installed in compliance with all applicable laws, regulations and codes, including plumbing codes. Instal- lation should be performed by a qualified plumbing contractor. JCUB SPECIFICATION Grease separator(s) shall be Thermaco Trapzilla hydromechanical grease interceptor system(s) as manufactured by Thermaco. Inc., Asheboro, North Carolina as noted on plans. SEPARATOR SPECIFICATIONS Furnish and install Thermaco Trapzilla Model No. TZ-160-ECA, rotationally molded polyethylene grease interceptors) for above or below ground installation, shall be rated at 35 gpm (2.21 Us) with 22.7 gallons (85.9 1) 1167.7 IDS. (76.1 Kg) of total grease storage capacity with flat separation efficiency curve capable of holding 84% of volume in free-floating fats, oils, and grease at capacity, with removable cover for grease and solids removal access, integral anti -flotation anchor ring for in -ground installation, integral horizontal baffle, laminar inlet flow diverter, integral vessel vent, separate storage compartments for grease and heavier than water solids, a unitary tank body and 3" (75 mm) inleVoutlet structures without gasket interfaces, utilizing an interior radial compression ring conjoining invert to tank outlet/inlet structures without bulkhead fittings and/or gaskets, invert top and bottom secured attachment points, sloping conical bottom for solids retention, integral sewer gas trap, and a fully re- movable polyethylene self -positioning cover with sealed thread fasteners. Includes one ECA-TZ-29 extension collar assembly. linear low -density rotationally molded polyethylene for field adjustability to optimal installation depth. SUBMITTAL OPTIONS 0 TZSP-40-ECA Sampling Port with 4" Inlet/Outlet, 0.5" fall and ECA-TZ-29 Extension Collar ❑ TZSP-48-ECA Sampling Port with 4" Inlet/Outlet, 7.8" fall and ECA-TZ-29 Extension Collar ❑ TSS-27-ECA Solids Interceptor for additional Solids Capacity ❑ VFCA-35 Vented Flow Control Assembly for installation at plumbing fixture level to limit flow to 35 gpm for installations With head height greater than 6' ❑ FTCA-22 Fabricated Top Cover Assembly with diamond plate aluminum surface for heavy duty fool -traffic, pallet jacks, food carts etc. (not rated for vehicle traffic) ( 12019 Thermaco, Inc- • All rights reserved • PatentedJPatents Pending • Specifications subject to change without notice Thermaco. Inc. • PO Box 2548 • Asheboro. INC 27204.2548 • (336) 629.4651 • www.trapzilia.com NOT TO SCALE PROLOGIS RENTON 9 601 MONSTER ROAD SW A PORTION OF THE NW 1 /4 OF SECTION 24, TOWNSHIP 23, RANGE 4 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON m E 0 GREASE INTERCEPTOR SINGLE VAULT SYSTEM 600 - 7,000 Gallon System - Dim "A" Clear Access Opening Contractor To Core Grill Or Knockout _ Hale In Field rP'pe 0 I N t" Draft l'-0"' o DETAIL I PLAN VIEW Slot Both Sides o Locking Frame & CoYer f Vent Pipes Adjust To Grade Alr & Gas Tight 1-Optional 2 27,00 3 Places (2 Places On 577-GA) L1 LID = -1 .ice LID =-7W.2•-A- LID =,,Q-?L�9fi_Q7 f i 2271 • BAFFLE OUT a ° >. ..a - Inspection Tee INLET T�� OUTLET -8.7- C1-- -- ------ -4 a--------i4 EL = •2449- L J 11 11 Tee or Elbow Ir 2252 = BAFFLE OUT tir,L _ I 14 iD Dim "E" c I c a 0 14 Water Depth IL 1 LJ 1 tD I E e Grout All Around got Len V Both sdes 3 11 Length B SECTION VIEW AA GGllon capa"t, r^. t500 2000 2500 3000 4000 5000 6000 Modd No. -s .!,-GA 612-1 12-CA 2-GA _ 2-Gu t4-CA 8-GA --'4 Olm'A- 0- 0- 0" _ -2- 12' _or -- 7_8" 1 '-t- 1 -_t' '-7- 1 11' 1 Dim "B- + 6' 4' a_" 5 0" 8' W-8' 6 a• 8 0- 8 0- 9' 7' a' 11- 91 1, Drm 'C• 7• 7' - r- : - g,_0• - g•_-• ®• - g� - Ic lo' D1m -D- 3'- 4'- 4'-: 4'-i 5'-6 1 " 5'- e _ e _ Water Depth Dim "E" 3'-3 4'-4 s-10 _ S' 3'-9 1/2- 4'-9" 4'-9 6,_3 Design Criteria: - Notes: Uniform Plumbing Code - Appendirc H 1, Concrete: 2a Day Compressive Strength rc - 7000 psi Number Of Meals x Waeto Flow Y Retention a Starvge -Capacity 2. Rebari ASTM A-615 Croce 60 w" Per Peak HoRate Time Factor In Gallons 3. Mesh- ASTM A-105 Grade 65 4_ Desigm ACI-318-02 Building Code ASTM C-657 'Minimum Structural Design Loading For Underground Precast Concrete Ut111ty Structures" 5. Loads: H-20 Truck Wheel w/ 3OX Impact Per AASHTO 6. Fill w/ Clean Water Prior To Start -Up Of System 7. Coe tractor To Supply & Install All Piping & Sampling Tees a. Gray water Only, Black Water Shell Be Carried By SCALE: 318 = 1'-0" Separate Side Sewer Items Shown Are Sugled To Grange Withoul Not - Issue Dal.: April 2016 131 O 19112-2016 Okkegle Precast, Inc. GREASE INTERCEPTOR #3 14'-6" x 40' CONC CROSSING INFO. SLAB - REFER TO GRADE = 26f 14'-6" x 20' CONIC STRUCTURAL PLANS IE 12" STM = 22.5t ROOF DRAIN SLAB - REFER TO SUBMITTED FOR TENANT CRN 4" WAT = 22.0f CLEANOUT STRUCTURAL PLANS IMPROVEMENTS UNDER ENCASE IN ETHAFOAM TO RIM = 26.0 SUBMITTED FOR TENANT SEPARATE PERMIT. PROTECT PIPE ® IE = 22.38 IMPROVEMENTS UNDER CROSSING. 00 SEPARATE PERMIT. - I I X I ROOF DRAIN Q 4" D.I. WATER 1 " PVC ROOF I / DRAIN ® 0. 0% CLEANOUT SUPPLY OR IN ® 0.30% /l- - 3" DOMESTIC RIM = 25.0 Q - - - - - - - - - - METER PER C.O.R. IE = 22.28 r - - 4" 45 4" D.I. WATEfja PLAN 3208" PVC DRAIN Pd.K � CItY SUPPLY + 90' BEND STD .4 ®0.50q BEND (MJ) MT& =4 4. �� 4' 90' BEND (Y SHACKLE 4"-90' BEND TO 7 4e( AD VALVE AND 4" VALVE I 4" GATE VALVE INSIDE VAULT UPSTREAM Q i -- OF METER lEE r. FL 4" TEE (FL) �' 4' TEE LINE�M �� 4" 45' " (FLxMJ) ADAPTER 8 11111 LED ON M D I I BEND (MJ) 4" (FLxMJ) I EAST SSE OF ME1M ADAPTER I --- -- -- - - - - - - - - - I I CROSSING INFO. 4" (FLxMJ) 4" 90' CUT IN (BY CITY FORCES) 3" RPBBEND (MJ)A IN ABOVE GATE VALVE GRADE = 25.9t NEW 12"x4" TEE (MJxFL) IF 8" STM = 22.5t 14 GROUND HEATED "HOT 4" 90' I I 4" GATE VALVE (FLxMJ) 6" D.I. FIRE CRN 4" I I BEND (MJ) BOX" (2'-2"x5'-10") w/ CONC. "C" CURB I WAT = 22.Ot PAINTED RED "NO I 12" GATE VALVE (MJ) HYDRANT & SPOOL I I ENCASE IN ETHAFOAM 6" DRAIN LINE (AWWA I SOUTH OF TEE TO PROTECT PIPE ® STDS.) PER C.O.R. STD. P.I.V. PER CITY PARKING", 7YP. CROSSING. PLAN 350.2 DETAIL 320.4 4" D.I. WATER CONC. 12THRUST 8 OCKI) SUPPLY 11 12" D.I. 12" GATE 14 I I 12" GATE 12" D.I. WATER MAIN 14 12" D.I. VALVE VALVE WATER MAIN WATER MAIN ---- - - - - --- -� - - - - - - - - - - --__ _--m- o - - - - - - L____--_ __--__-__--�il- �-�i------�_-__®____-_a ___-____ ENLARGER WATER CONNECTION DETAIL 1 REVISED PER CITY COMMENT LETTER DATED 12/21 18 JRE 04 02 19 11009 1 1 UCTED 2 REVISED PER CITY COMMENTS DATED 05 07 19 JRE 06 03 19 3 REVISED PER CITY COMMENTS TO C2.0, C6.0 & C6.2 JRE 06 21 19 4 REVISED PER CITY COMMENTS TO C6.0 JRE 06 25 19 5 REVISED PER CITY COMMENTS TO NGPA & WALL HEIGHTS JRE 07 23 19 6 REVISED WATER QUALITY TREATMENT VAULT C3.0, C3.1, C3.4, & C3.5 JRE 08 20 19 N 7 CONSTRUCTION COORDINATION SET JRE 10 21 19 8 CONSTRUCTION COORDINATION SET - PSE/SDWLK REVISION JRE 12 20 19 8A REVISED WATER CONNECTION PER CONFLICT WITH HP GAS MAIN STN 10 30 19 g PSE/SDWLK REVISION CITY COMMENTS C6.0 & C6.2 JRE 1 14 2020 10 CONSTR. COORD. REVISED ROOF DRAIN CLEANOUTS, ADDED CB#7A JRE 1/16/2020 SURVEYED: SCALE: 1 w = 2or 1 1 REVISED WATER SERVICE LINE TO BUILDING JRE 5 13 2020 DESIGNED: J. Eaves/J. Hein 12 REVISED ADA RAMP DETAIL 2, SHEET C6.2 JRE 7 24 202Q 13 REVISED UTILITIES FOR TENANT IMPROVEMENTS JRE 8 27 2020 / / J. Eaves/J. Hein 14 REVISED PER CITY TENANT IMPROVEMENT COMMENTS JRE 9/15/2020 CHECKED: ONE INCH AT FULL SCALE S. Nelson IF NOT NO. REVISION BY DATE APPR APp�: SCALE ACCCOO INCH RDINGLY SCALE: 1 "=5' NOT TO SCALE RECORD DRAWING 03-15-2021 RECORD DRAWING NOTE: THIS CONSTRUCTION RECORD DRAWING IS A COPY OF THE APPROVED CONSTRUCTION DRAWINGS PREPARED BY INNOVA ARCHITECTS AND HAS BEEN EDITED TO REFLECT ASBUILT CONDITIONS. THE INFORMATION PROVIDED ON THESE RECORD DRAWINGS IS A COMBINATION OF FIELD SURVEYED INFORMATION AND DOCUMENTED FIELD REVISIONS. o' 2.5' S' 10 Know what's below. Call before you dig. N.A�HORIZTAL:N[19/1991 4 CITY OF %1 RENTON DATUM Planning/Building/Public Works Dept. REUSE OF DOCUMENTS THIS DODYI31T WS BEEN SIGNED ELECTRONICALLY IN ACCORDANCE WTH WAC 196-23-070 AND CHAPTER 19.34 RCW. UNAUTHORIZED ALTERATION OF ANY OF THE INFORMATION ON THIS M MENT WIL INVALIDATE THE DOCUMENT, MY CERTIFICATION AND SIGNATURE THE DEAS AND DESIGNS INCORPORATED 14ERETN. AS AN NSIRl1MENT OF THE PROFESSIONAL SERVICE, IS THE PROPERTY OF INNOVA ARCHITECTS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PRO.ECT UTHOUT WRITTEN AUTHORIZATION OF INNOVA ARCHITECTS T r� architects 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 253-572-4903 ient: PROLOGIS 12720 Gateway Dr., Suite 110 Tukwila, WA 98168 206-414-7625 S-404203B W-404203B R-404216B IN COMPLIANCE WITH CITY OF RENTON STANDARDS 44 DEVELOPMENT ENGINEERING Bbannwarth 10/28/2020 0 PROLOGIS RENTON 9 601 MONSTER ROAD SW Record Drawing documents 03-15-2021 ADDITIONAL TENANT UTILITY IMPROVEMENT PLAN Z W IV DATE 11/16/18 CD O TiELD800K: PAGE IDRAW1Nc No: J C5.0b O SHEET: OF: 16 51