HomeMy WebLinkAboutMFP21004555.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP21004555
IVR Number: 21004555
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:09/21/2021Application Date:7225500375Parcel Number: 320 WILLIAMS AVE N
Permit Type:10/06/2021Issue Date:Franchise
Permit Work Class:10/06/2022Expiration Date:Minor Utility
Job Number: 101135492Franchise Type:Electric
Description: Puget Sound Energy Electric CREW TO PARK IN ROW AND AND INSTALL SERVICE AT P01 (318090 166086).
POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
6905 S 228TH St
KENT, WA 98032
C: (253) 905-5031ApplicantX
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
FITTERER MARCUS 2537 HOWSTON CT
RICHLAND , WA 99354
Owner
Corrie Rydberg
Puget Sound Energy
6905 S 228TH St
KENT, WA 98032
C: (253) 905-5031Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 1ϭ/Ϯϱ/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 1ϭ/Ϯϱ/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.܆ A copy of the Traffic Control Plan (TCP) Application form.
2.܆ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
܆ Include map(s) showing the location of the project and work area.
܆ Be legible lettering and clear, contrasting, symbols of viewing or printing.
܆ Must indicate street names, and north arrow and scale.
܆ All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
܆ Types of plans required:
܆ Work hour plan – show all mobility impacts during construction hours.
܆ Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
܆ Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
܆ Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
4
4
4
4
4
4
4
4
4
4
4
101135492
320 WILLIAMS AVE N
PLEASE SEE ATTACHED
POTELCO, INC 425 892 0416
ROBERT SANBORN ROBERT.SANBORN@PSE.COM
6905 S. 228TH ST KENT, WA 98032
MFP21004555
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 10/6/2021
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 1ϭ/Ϯϱ/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
x TCP must be approved prior to commencing the work, and all permit conditions shall be met.
x Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
x Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
x The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
x Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
x Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
x TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
x Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
x Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
x The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
x In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
x Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
x Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
x Approved Temporary TCP must be at the work site during work hours.
x Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
x Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
x Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
x Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
x The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
x Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
CORRIE RYDBERG
1717 111111111111N 3rd
S
T
N 3rd
S
T
WILLIAMS AVE NP01 P02
P03
320 M1 M2HH01
1717
ONE WAYONE
W
A
Y
ONE
W
A
YSHOULDERWORKW21-5ROADWORKAHEADW20-1100'100'SHOULDERWORKW21-5ROADWORKAHEADW20-1100'100'1717ONE WAY1717ONE WAYS/W
CLOSED R9-9S/WCLOSEDR9-9CROSS HERE
SIDEWALK CLOSEDAHEAD
N 4TH ST
RESIDENT(S) WILL BE INFORMED
OF POSSIBLE TEMPORARY
DRIVEWAY CLOSURE
PLACE SIGNS
BOTH SIDES OF
WORK AREA
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC
000
0
000000 NO PARKINGNO-PA
R
K FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PAR
K CROSS HERESIDEWALK CLOSEDAHEADONE WAY ONE WAY
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
POLE
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
TEMPORARY TRAFFIC CONTROL PLAN
N
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m.
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
09/07/2021
101135492
0
320 Williams Avenue N, Renton, WA
Ina Ustemchuk
425-398-6063
ina.ustemchuk@pse.com
1 OF 1
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 012238
Card Exp. 09/30/2023
gregory.harwood@pse.com
(425)424-6425
MFP21004555
341
334
328
320
339
333
316
329
325
321
317
312
310
800
335
331
327
323
317
315
313
307
301
814
315
309804WILLIAMS AVE NN 3R
D
S
T
N 3
R
D
S
T
318090-166086
25 kVA 120/240V (C)
SLAG7901
318090-166101
318088-166112
4/0 UG TPLX
L=200'
4/0 UG TPLX
L=100'
350 UG TPLX
L=50'
350 UG TPLX
L=50'
TRANSFER OH TRIPLEX
TO P03
WORKSITE
WORKSITE
SITE PLAN
POWER GENERAL NOTES - RESIDENTIAL PROJECT
N
Vicinity Map
N/A
Owner / Developer Contact Info
officeATTN:
Ken Ponder
316 WILLIAMS AVE N
RENTON, WA 98057
Ken Ponder 425-255-1184
SITE SPECIFIC NOTES
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
OH SVC Removal
OH-UG SVC CON
OH SVC Removal
OH-UG SVC CON
OH OPS
Pole Removal
Superior
ORDER#NOTIF#
PWR
PROJECT PHASE
101135493510511829
108125943
101135491510511537
593229447
108123190
CABLE TV
PHONE
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
10.
7.
6.
5.
4.
3.
2.
1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
Roads shall be paved or have a compacted , crushed rock base in place.
CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
All work is to be done in accordance with local municipal and county permit requirements as applicable.
Inclement weather conditions may cause delays in construction times and dates.
EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over
PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer
will provide any and all shoring or they will side slope the trench to 1:1.
8.
9.
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager: ROBERT SANBORN425-748-6386
robert.sanborn@pse.com
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"
X
X
XX
SCALE: 1" = 50'101135492THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
101135492
108125946
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
R. SANBORN
PHONE NO
425-748-6386 07/14/21
R. SANBORN 425-748-6386 07/14/21
N/A
QC. NGUYEN 425-748-6310 07/14/21
N/A RENTON
THOMAS PONDER
POLE REPLACEMENT, NEW HH, UG SEC L/E, (3) OH-UG SVC CONV
316 WILLIAMS AVE N, RENTON WA
N/A N/A
N/A 101135492
AS NOTED 1/1
KING N/A N/A QCNOKE
NW17 T23N R05E N/A N/A
2305E066 2305E088 2305E066NW GRA-17
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
510282548
P01 GRID #318090-166086
- EXISTING POLE & OH XFMR TO REMAIN
- INSTALL (1) NEW 3” SECONDARY RISER [RIS3CSS] PER STD. 6042.1000
P02 GRID #318090-166101
- REMOVE EXISTING 35' CL3 POLE
P03 GRID #318088-166112
-INSTALL (1) NEW 35' CL3 (2021) POLE [PS353] AS STAKED PER STD. 6010.1100
- TRANSFER EXISTING OH SEC FROM P02 TO P03
- INSTALL (1) NEW 3” SECONDARY RISER [RIS3CSS] PER STD. 6042.1000
HH01
- INSTALL NEW 13"x24" FG HANDHOLE [HH14350] PER STD 6050.2000
- INSTALL (3) 4 POS FARGOS
- CONNECT (1) RUN OF CUSTOMER OWNED SVC
P01 TO HH01
-POTELCO TO TRENCH & INSTALL 3" DB120 CONDUIT, L=50' (ACTUAL=___')
- INSTALL (1) RUN OF #350 UG TPLX, L = 80' (ACTUAL=___')
P01 TO P03
- TRANSFER EXISTING OH SEC FROM P02 TO P03
HH01 TO MTR "M1"
-POTELCO TO TRENCH & INSTALL (1) 3” DB120 CONDUIT, L = 90” (ACTUAL = ___')
- INSTALL (1) RUN 350 UG TPLX, L = 100' (ACTUAL = ___')
HH01 TO MTR "M2"
-POTELCO TO TRENCH & INSTALL (1) 3” DB120 CONDUIT, L = 190” (ACTUAL = ___')
- INSTALL (1) RUN 350 UG TPLX, L = 200' (ACTUAL = ___')
P03 TO MTR "M3"
-POTELCO TO TRENCH & INSTALL (1) 3” DB120 CONDUIT, L = 20” (ACTUAL = ___')
- INSTALL (1) RUN 350 UG TPLX, L = 50' (ACTUAL = ___')
***CUSTOMER TO PROVIDE ALL TRENCHING, CONDUIT, BACKFILL, & RESTORATION**
***CUSTOMER TO PROVIDE 3/8" NYLON PULL ROPE IN CONDUITS***
Field Face
Quadrant
Road Face
Quadrant
Climbing
Space
5" MinCL
Direction of Vehicular TrafficCL
TOP VIEW
CONDUIT RISER PLACEMENT DETAIL (P01)
SCALE: NONE
SIDE VIEW
15"
23-1/4"32-3/4"
2"
Captive L-Bolt
Lock Cover, 10 lbs
24"
Approx
Approx
13"
Customer's
service
conductors
4-3/4" X 4-3/4"
KNOCKOUT IN 2 PLACES
Conductors enter from
beneath and shall be
folded back with handhole
TOP VIEW
5'-0"
4'-0"
SINGLE PHASE SECONDARY HANDHOLE
SCALE: NONE 6050.2000
TV & TEL
Excavated Dirt Pile
Final Grade
24" Min
24" Min
to
36" Max
Cover
Backfill for Conduit
Free of rocks
larger than 8"
in diameter
Separation
12" Min
in Conduit
Schedule 40 White PVC
Gas Service Line
32" Typical
(Power, Gas,
Phone & Cable)
Separation
12" Min
12" Min
Separation
36" MINIMUM COVER
IN RIGHT OF WAY
JOINT TRENCH DETAIL
Joint Service Line in Conduit (NTS)
To Excavated Dirt Pile
Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,
glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.
Separation
12" Min
Secondary Power Cable in Customer-provided
3" Schedule 40 Grey PVC Conduit
SECONDARY CABLE & CONDUIT TABLE
Work
Location
Cable
Assumed
Lot Corner
Conduit
Voltage
Drop
Voltage
Flicker
As Built Information
Size Length
Design
(ft)
Size Length
Design
(ft)
Bends Foreman - Complete
FROM TO (1/0,4/0,350)to Meter(ft) (in)90°45°22° 11°(Percent) (Percent) Actual Amount Installed (Conduit & Cable)
P01 HH01 SEC 350 UG
TPX 80'0 3"50' 3 0 0 0 ----
kWh Mtr
Elec. Mtr Base
12" Min 36" Typical
24" to 36" Max
Conduit Depth
Power Cable Conduit
Customer Provided
3" Schedule 40 Grey PVC
Regulator Vent
Utility-Provided
Gas Meter Assembly
Min
36"
Customer Provided
Conduit Stakes
48"
48"
Top View 4'
3" Conduit Service Riser
from Gas Service Lines
12" Minimum Clearance
Customer Provided
Drainage Pipe
Work Pit Dimensions
Electric & joint Utility
4'
MTR BASE DETAIL
SCALE: NONE
UTILITY POLE EROSION CONTROL DETAIL
TOP VIEW
FLOWING DITCH or BODY OF WATER
SLOPE
Secure bottom of fence
with gravel bags
Place straw mulch
on disturbed areaExcavated or
Augered Hole
Pole
SLOPE
Not to scale Adjacent to flowing ditches or bodies of water
Install silt fence around
pole excavation
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
Wk
Loc
Pole Data Pole
TEL TV FIBER TRAN RMVD ID NUMBER
Grid #Length Class Year TOPPED RMVD
P02 318090-166101 45'CL3 1961
POLE TABLE (NEW)
Work
Location
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P03 318088-166112 35 CL-3 2021
P01 - P03
Conductor: #4/0 OH TPLX
Runs: 1
KW Load: 12.1 kW
SVC Length: 200
%VDrop: 1.5%
%Flicker: 3.8%
@XFMR (P01)
Load: 37.3 kW
LRC: 65 AMPS
% V. Drop: 2.9%
% Flicker: 1.5%
P03 - MTR "M3"
Sq. Footage: 3,600 SQ.FT
Panel Size: 320 AMPS
Heat Type: GAS
Conductor: #350 UG TPLX
Runs: 1
KW Load: 15.3 kW
SVC Length: 210'
%VDrop: 1.5%
%Flicker: 3.8%
P01 - HH01
Conductor: #350 UG TPLX
Runs: 1
KW Load: 7.3 kW
SVC Length: 80'
%VDrop: 3.0%
%Flicker: 1.8%
@XFMR (P01)
Load: 37.3 kW
LRC: 65 AMPS
% V. Drop: 2.9%
% Flicker: 1.5%
HH01 - MTR "M1"
Sq. Footage: 3,600 SQ.FT
Panel Size: 320 AMPS
Heat Type: GAS
Conductor: 4/0 UG TPLX
Runs: 1
KW Load: 12 kW
SVC Length: 210'
%VDrop: 3.6%
%Flicker: 2.5%
HH01 - MTR "M2"
Sq. Footage: 3,600 SQ.FT
Panel Size: 320 AMPS
Heat Type: GAS
Conductor: 4/0 UG TPLX
Runs: 1
KW Load: 12 kW
SVC Length: 210'
%VDrop: 3.6%
%Flicker: 2.5%
8/26/21
MFP21004555
POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS