Loading...
HomeMy WebLinkAboutR-417741n n v Q' 30 W ~ 20 10 0 -10 -20 10+00 1124-18 SADDLE MANHOLE - 48" RIM = 19.36 IS (IN) = 13.94 (15" EX GONG S) IE (OUT) = 12.70 (18" HDPE W) 30 FINISHED GRADE AT � OF PIPE 20 EX GRADE FINISHED GRADE SEE APRON R 17 E% STORM AT @ OF PIPE AT q OF PIPE PLANS FOR 26LF 18" HDPE 18° STORM 6" EX. ELF (ANN) 12" STORM 18° STORM 6 CONTINUATION ® 0.209. 24LF 18" HDPE 0 0,20% 6" FIRE MEN immomp 58LF 30" HDPE ® 0.18% 45LF 30` HDPE ® 0.20% 13OLF 30" HDPE 0 020% 1 2 3 335LF 30" HOPE 0 0.21% ' I POWER 5 1122-18 1 AIR SDMH TYPE 3 - 48" 1120-18 4 RIM = 19.47 SDMH TYPE 3 - 54" IF (IN) = 12.60 (18" HOPE S) E RIM = 19.67 WATER 1092-18 SDMH TYPE 3 - 54" 1093-18 IE (= IF (IN) = 15.00 (12- HDPE S) (18" HDPE W) RIM = 19.09 SDMH TYPE 3 - T) 12.2.60 (30° HDPE NIE (IN) 12.40 (30" HDPE E) IE (OUT) IF (IN) = 12.12 (30" HOPE 5) RIM = ??? ???) 1121-18 IE (OUT) = 12.40 (30" HDPE N) IE (OUT) = 11.39 (30° HDPE NW) IS (IN) 11.13 (30" HDPE SE) SDMH TYPE 3 - RIM = 18.96 IF (OUT) = 11A3 (30° HDPE N) 3054" 1123-18 IE (IN) = 12.49 (30" HDPE S) 30" PVC DRAIN IE (OUT) = 12.49 (30° HDPE W) W/SOLID LOCKING LID RIM = 19.49 IS (IN) = 12.65 (18" HDPE E) IE (OUT) = 12.65 (18" HDPE N) EX GRADE AT iOF 10 1129-18 24" PVC DRAIN W/HERRINGBONE GRATE PROVIDE 2' SUMP 0 RIM = 18.75 IE (OUT) = 15.70 (12" HDPE S) 1128-18 30" PVC DRAIN -10 W/SOLID LOCKING LID RIM = 18.86 IE (IN) = 15.54 (12" HDPE N) IS (IN) = 15.27 (12° EX DI S) IF (OUT) = 15.27 (12" HOPE W) -20 0+00 30 20 10 11 -10 -20 10+00 11+00 12+00 1124-18 TO 1093-18 SEE SHEET C501-6A THROUGH C601-6C 1 •LF 18" HOPE u E F'. _me 0 -MILLI_- !1■_ �- 1 ��SUMMER - 15.18 1 1126-18 SADDLE MANHOLE - 48" 11 RIM = 19.55 70LF z" HDPE ® 0.20% 0 IS (IN) = 14.95 (12" EX CONC S) IE (IN) = 15.13 (12- HDPE E) IE (IN) 15.00 (12° HDPE N) 18° STORM IE (OUT) = 14.95 (18" HDPE W) 1 4900-14 1125-18 EXIST CB TYPE 1 30" PVC DRAIN RIM = ??? -10 W/SOLID LOCKING LID IS (IN) = 13.72 (12" E% CONC S) RIM = 19.71 IF (IN) = 16.50 (8" EX DI W) IF (IN) = 1C89 (18° HDPE E) IE (OUT) = 13.72 (12° EX HDPE N) IS (IN) = 13.15 (12" HDPE SW) IS (OUT) = 13.28 (12° HDPE NE) IE (OUT) = 13.13 (18" HDPE N) -20 1+00 2+00 2+60 1129-18 TO 490D-14 SEE SHEET C501-6C 10 EX AT GRADE @ OF PIPE EX GRADE AT � OF PIPE r EX. POWER 12 - -- T I 46LF 8" DI 0 0.210% 44LF 8" DI @ 0,20% ' ' 476-18 11 8" EX. FW CB TYPE 1 74LF 8" DI 0 0.30% 15" STORM PROVIDE 2' SUMP 474A-18 RIM = W9 CB TYPE 1 IS (IN) = 17.05 (8° DI E) PROVIDE 2' SUMP IE (IN) = 17.44 (6" EX CI S) RIM = 1?? IE (OUT) = 17,05 (8" DI N) IE (IN) = 16.74 (8" DI E) IS (IN) = 16.74 (12 CONC S) IF (OUT) = 16.74 (12" CONC N) 47BA-18 CB TYPE 1 476A-18 PROVIDE 2' SUMP CB TYPE 1 RIM = ??? PROVIDE 2SUMP IE (IN) = 17.15 (8" SLOT DRAIN S) RIM = ??? IS (OUT) = 17.15 (8° DI W) IE (IN) = 16.97 (8" DI S) IE (OUT) = 16.96 (8" DI W) 11 +00 478A-18 TO 474A-18 SEE SHEET C501-61) WSP AC "( 3330I 9NA eX tl CALL 48 HOURS 1 I 300 w ai fetl:( Wry, 9B0012Kb BEFORE YOU DIG 1- o )431-2250 1-QDB-424-.>SrJ.> FAX: (i(6)431-E350 FAX:(�) SYM RENSION SY APPROVED MM ORIG APRON R - CENTRAL C180242 WSP SPT I 07/09/21 R&190N 30 20 10 I -10 -20 11+80 BY I APPROVED I DATE 13+00 30 20 10 I -10 EX GRADE AT @ OF PIPE -FINISHED GRADE 57LF 12 AT OF PIPE 1126-18 SADDLE MANHOLE - 48" RIM = 19.55 IF (IN) = 14.95 (12" EX GONG S) IS (IN) = 15.13 (12" HDPE E) IS (IN) = 15.00 (12" HDPE N) IE (OUT) = 14.95 (18" HOPE W) 1127-18 SAFE DRAIN RIM = 18.75 IF (OUT) = 15.12 (12` HDPE S) 14+00 30 20 SUMMER - 15.18 WINTER - 13.18 10 0 -10 -20 14+28 30 HDPE 0 0.20% 20 SUMMER - 15.18 10 9 -10 -20 -20 3+00 3+67 1127-18 TO 1126-18 SEE SHEET C501-6C BOOFF WINTER - 13.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED�PTTC GENERAL NOTES 1, HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICA DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. 2. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. 3. REMOVE SECTIONS OF ABANDONED PIPES AS REQUIRED WHEN IN CONFLICT WITH NEW STORM CONDUIT. SEE PIPE ABANDONMENT PROCEDURE ON SHEET C501-18. 4. PROVIDE 6" MINIMUM VERTICAL CLEARANCE FROM O.D. AT STORM CROSSINGS 5. PROVIDE ETHAFOAM BETWEEN PIPES WHERE 6" MINIMUM CLEARANCE CANNOT BE ACHIEVED 6. SEE GENERAL NOTES ON SHEETS C501-1B. 7. ® UTILITY CROSSING. SEE PIPE CROSSING TABLE ON SHEET C501-6G PIPE ABANDONMENT 1. REMOVE SECTIONS OF ABANDONED PIPES AS REQUIRED WHEN IN CONFLICT WITH NEW STORM CONDUIT. SEE PIPE ABANDONMENT PROCEDURE ON SHEET C501-11E. 20 0 20 40 HORZONTAL: scale feet 10 0 10 20 VERTICAL: scale feet [CIVIL PER E STORM DETAILS APRON R - CENTRAL RENTON SITE MASTER S 11 RENTON, ' R-4177041 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEMWNEMEMINEMIM O ichavez 08/25Y2021 C160242U N I b 07/09/21 ;501-6E C41 COMP C 180242 RTN-YD-0501-6E