HomeMy WebLinkAboutR-417743PIPE CROSSING TABLE CROSSING # PIPE ABOVE BOTTOM ELEVATION PIPE SIZE PIPE BELOW TOP ELEVATION PIPE SIZE VERTICAL CLEARANCE OEX STORM 14.79 12.00" STORM 14.24 18.00" 0.55' OSTORM 14.91 18.00' STORM 14.19 18.00' 0.72' O3 FIRE 15.54 6.00" STORM 14.93 30.00" 0.61' 4O STORM 12.06' 30.00" JUT 10.88 2.00" 1.18' OSTORM 15.02' 12.00" STORM 13.94 30.00" 1.08, 6O STORM 14.47' 18.00" STORM 13.82 30.00" 0.65' 7O EX WATER 15.88 8.00" STORM 14.39 12.00" 1.49' 8O EX FIRE 14.88 12.00" STORM 14.38 12.00" 0.5' 9O EX AIR 16.38 8.00" STORM 14.36 12.00" 2.02' ID STORM 17.09 12.00" STORM 16.11 15.00" 0.98, 11 STORM 16.82 12.00" EX POWER UNKNOWN UNKNOWN - 12 STORM 16.70 12.00" EX FIRE 16.02 8.00" 0.68' 13 STORM 15.41 12.00" FIRE 13.88 6.00" 1.53' 14 STORM 14.83 12.00" JUT 13.88 8.00" om, 15 EX SS 16.55 6.00" STORM 15.51 12.00" 1,04' • CROSSING PIPES HAVE LESS THAN 6" CLEARANCE BETWEEN THEM SEE NOTE 5 ON C501-6E. WSP "( 3330I9 e X tl CALL 48 HOURS 1 I 300AC w al fetl: Wry, 12Kb BEFORE YOU DIG )431-z300 (2 1-DOO 1-800-424-5555 FAX:(m FAX: (i(6) 431-E350 SYM RENSION SY APPROVED MM CRIS APRON R - CENTRAL C180242 WSP SPT I 07/09/21 REVISION BY I APPROVED I M1 i L -BOEArw" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED�PTTC [CIVIL PER E STORM DETAILS APRON R - CENTRAL RENTON SITE MASTER S 11 RENTON, ' R-4177043 IN COMPLIANCE WITH CITY OF RENTON STANDARDS OEVELORIEMENOIXEERIXO ichavez 08/26/2021 O C180242UKIb 07/09/91 501-6G DMP C43 C180242 RTN-YD-0501-6G