HomeMy WebLinkAboutR-417749PIPE ANCHORING NOTES: 1. VARIABLE HIGH GROUND WATER CONDITIONS ARE PRESENT THROUGHOUT THE SITE. DEPTH TO GROUNDWATER IS TIED TO LAKE WASHINGTON WATER LEVEL WHICH VARIES SEASONALLY. BUOYANT FORCES ACTING ON PIPE WILL VARY WITH LAKE LEVEL AND PAVEMENT CONDITIONS THROUGHOUT CONSTRUCTION. SEE STORMWATER PROFILES ON SHEETS C500-6C THROUGH C500-61) FOR PIPE INVERT AND SEASONAL LAKE ELEVATIONS. 2. PRE -CAST CONCRETE PIPE ANCHOR OR ENGINEER APPROVED EQUIVALENT ARE REQUIRED ON ALL OUTFALL PIPES AT 10'-0" CENTER BEGINNING AT 5'-0" FROM THE DOWNSTREAM END OF PIPE. CONTRACTOR SHALL PROVIDE EQUIVALENT CONCRETE ANCHORS TO MEET THE MINIMUM WEIGHT REQUIREMENTS SHOWN. ANCHORS SHOULD BE SIZED APPROPRIATELY WITH REGARD TO WEIGHT REQUIREMENTS AND METHOD OF INSTALLATION. 3. ADDITIONAL ANCHORING MAY BE REQUIRED FOR EMPTY PIPE INSTALLED BELOW THE SEASONAL GROUND WATER TABLE. MINIMUM COVER DEPTH OVER PIPE AS SHOWN IN TABLE MUST BE ACHIEVED -OR- APPROVED PIPE ANCHORING SYSTEM INSTALLED PRIOR TO EXPOSING EMPTY PIPE TO FULLY SUBMERGED GROUNDWATER CONDITION. REINFORCED PRECAST CO HOPE PIPE ADD Pi BETWEEN CONCRET ANCHOR AND PIPE 1" MIN. DIAMETER LOCKING BOLTS FOR HOISTING C C C501-6B C501-6C HDPE PIPE MINIMUM ANCHOR REQUIREMENTS DIMENSIONS (INCHES) PIPE O.D. 36 30 24 18 12 A 60 50 40 30 24 B 29 24 19 14 11 C 23 24 24 25 17 MINIMUM REQUIRED ANCHOR WEIGHT (LBS/EA) ANCHOR 0 10' OC 3500 2450 1600 "1 400 MINIMUM REQUIRED SOIL DEPTH (INCHES) D (SOIL DEPTH) 15 1/2 15 1/2 15 1/2 15 1/2 15 1/2 Dd (DRY SOIL) 12 12 1 12 1 12 1 12 C501-6D PIPE CONCRETE COLLAR N T w A `O" RING 12" QUARRY MANHOLE RING AND COVER PER WSDOT STD PLAN B-30.70-03 BLAXRL 1500 iE RID �/\//I SEPARATE BASE INTEGRAL BASE AIRCRAFT RATED TYPE 3 MANHOLE C501-68 SCALE: NITS \1—/ C501-6C APRON R FINISHED GRADE FRAME AND GRATE 24" TYR C4 x 30" EPDXY ' - - COATED REBAR (8 PLACES) qb PAINT RED BLOCK PAINT WHITE BACKGROUND LETTERS SIZED TO FIT DRAINAGE STRUCTURE AVAILABLE SPACE TYP. 2" CLR VALVE BOX 041 VALVE BOX INSTALL AS CLOSE TO (TYP) SEE DETAIL C>-( INSTALL AS CLOSE TO STRUCTURE AS POSSIBLE STRUCTURE AS POSSIBLE } VALCOM POSITION INLET PIPE FROM OUTLET PIPE .r X INDICATOR MODULAR WETLAND TO OUTFALL VALVE BOX LID SEE DETAIL PAINT MARKINGS BENEATH LID TIDEFLEX CHECKMATE UPSTREAM CLAMPED CHECK VALVE OR TIDEFLEX CHECKMATE DOWNSTREAM APPROVED SIMILAR. CLAMPED END CLAMPED CHECK VALVE OR TOWARDS DRAINAGE STRUCTURE APPROVED SIMILAR. CLAMPED END FOR MAINTENANCE ACCESS. TOWARDS DRAINAGE STRUCTURE FOR MAINTENANCE ACCESS. NOTES: 1. TIDEFLEX CHECKMATE INLINE CHECKMATE SHALL BE INSTALLED PER THE MANUFACTURERS RECOMMENDATIONS. 2. INSTALL INURE CHECK VALVE AS CLOSE TO NEAREST DRAINAGE STRUCTURE AS POSSIBLE FOR MAINTENANCE. 3. THE CLAMPED END OF THE INLINE CHECK VALVE TO GO TOWARDS THE NEAREST DRAINAGE STRUCTURE FOR REPLACEMENT OF CHECK VALVE IF NECESSARY. C VERIFY SIZES OF PIPES AND REQUIRED INLINE CHECK VALVE SIZE WITH MANUFACTURER BEFORE INSTALLATION. SCALE: NTS WSP AC "( 3330I 9N AxmeX tl CALL 48 HOURS 1 I 300 w aI fe Wry, 12Kb BEFORE YOU DIG L: (Z 1-BOO 1-QDD-424-.>JrJ.> FAX: QM)431-2250 FAX: (i(6)431-E350 SYM 1 RENSION BY APPROVED DATE ORIG I APRON R - CENTRAL C1802421 WSP I SPTI 07/09/21 e7c&M1T UPPER VALVE BOX LOWER VALVE BOX SEE ABOVE DETAIL FOR PAINT MARKINGS UNDERNEATH VALVE BOX LID VALVE BOX LID SEE DETAIL TYPICAL PAVEMENT SECTION p. i a z� 00 2" AWWA NUT o � I y� wn VALCOM LOW PROFILE 'ate c`i POSITION INDICATOR c CIRCULAR ADJUSTMENT SECTION REINFORCED FLAT SLAB TOP CHANNEL AND SHELF CSBC REINFORCING STEEL UPPER VALVE BOX o CORE DRILL AND KOR-N-SEAL BOOT SD o VALVE BOX TO o OLYMPIC FOUNDRY VBU-8215 OR SIMILAR w "SD" TEXT ON LID CAST IRON 5 J" SLIP TYPE VALVE BOX OR SIMILAR TYP. 6" MIN VALVE BOX AND LID CRUSHED ROCK BASE COURSE — TRUMBELL VALVE EXTENSION SEE TYPICAL PAVEMENT SECTIONS STORM VALVE C501-6C SCALE: NTS REVISION I BY I APPROVED I DATE �BOE LOWER VALVE BOX ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED�PTTC 12" PLAN VIEW CONCRETE COLLAR s STEPS OR LADDER MIN \RATION IT SHAPED KNOCKOUT I (STING JOINT MANHOLE RING AND COVER PER WSDOT STD PLAN B-30.70-03 CIRCULAR ADJUSTMENT SECTION — REINFORCED FLAT SLAB TOP PRECAST REINFORCED 24:1 CONCRETE SECTION SLOPE FORM CONCRETE BASE / AND CHANNEL IN FIELD SCOPE _ I I "U" SHAPED MANHOLE KNOCKOUT TO INSTALL MANHOLE OVER EXISTING PIPE. PROVIDE 2" MIN CLEARANCE AROUND PIPE AND GROUT. F OF EXISTING PIPE. TOM HALF TO REMAIN MANHOLE CHANNEL BIAXIAL 1500 GEOGRID T OR CAST -IN CONCRETE SLAB SECTION A 1 AIRCRAFT RATED TYPE 3 SADDLE MANHOLE -613 SCALE: NITS -6C [CIVIL PERMIT E STORM DETAILS APRON R - CENTRAL RENTON SITE MASTER S 11 RENTON,' R-4177049� IN COMPLIANCE WITH CITY OF RENTON STANDARDS C1802421 07/09\I .501-6N DMP C49 C 180242 RTN-YD-0501-611