Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R-417762
n n v a Q LL IRRIGATION SCHEDULE MBOL 4 O MANUFACTURER/MODEL RAIN BIRD 1812-SAM-PRS SO SERIES RAIN BIRD 1812-SAM-PRS 15 STRIP SERIES RAIN BIRD 1812-SAM-PRS 15 STRIP SERIES RAIN BIRD 1812-SAM-PRS 15 STRIP SERIES RAIN BIRD 1812-SUM-PRS 15 STRIP SERIES RAIN BIRD 1812-SAM-PRS 10 SERIES MPR RAIN BIRD 1812-SAM-PRS 10 SERIES MPR RAIN BIRD 1812-SAM-PRS 12 SERIES MPR RAIN BIRD 1812-SAMM-PRS VAN SERIES ARC al fL RADIUS 180 30 0.20 4' EST 30 0.61 4'x15' LCS 30 0.49 4'x15' RCS 30 0.49 4'x15' SST 30 1.21 4'x3O' 180 30 0.79 10' 90 30 0.39 To' 90 30 0.65 12' ADJ 30 6' RAIN BIRD 1812-SAM-PRS VAN SERIES ADJ 30 18, RAIN BIRD 1812-SAM-PRS HE -VAN SERIES ADJ 30 10' RAIN BIRD 1812-SUM-PRS HE -VAN SERIES ADJ 30 12' ELy SYMBOL MANUFACTURER/MODEL/DESCRIPTION \\ HUNTER PGV-101-MM-DC 1" PLASTIC ELECTRIC REMOTE CONTROL VALVE, FOR \\ X j RESIDENTIAL/LIGHT COMMERCIAL USE. MALE X MALE \\ IV2N III (NPT THREAD) INLET/OUTLET. GLOBE CONFIGURATION, WITH FLOW CONTROL. DC LATCHING SOLENOID. NIBCO T-113-K \ III CLASS 125 BRONZE GATE SHUT OFF VALVE WITH CROSS \ HANDLE, SAME SIZE AS MAINUNE PIPE DIAMETER AT VALVE LOCATION. SIZE RANGE - 1/4" - 3" 3/4 \ \ RAIN BIRD 33-DLRC OP e 0 0 3/4" BRASS QUICK -COUPLING VALVE, WITH _ CORROSION -RESISTANT STAINLESS STEEL SPRING, LOCKING THERMOPLASTIC RUBBER I _ a/4, / / COVER, DOUBLE TRACK KEY LUG, AND 2-PIECE BODY. HUNTER NODE 200 e // 2-STATION CONTROLLER, OUTDOOR, BATTERY _--------___ _ 2 28.8 // I POWERED WITH DC LATCHING SOLENOID I 2" 5 (TYP) Q / IRRIGATION LATERAL LINE: PVC SCHEDULE 40 J' — — — — IRRIGATION MAINLINE: PVC SCHEDULE 40 2 STATION OPERATED _ BATTERY �\ CONTROLLER - - - - - - - - PIPE SLEEVE: PVC SCHEDULE 40 VALVE CALLOUT # # #" VALVE NUMBER VALVE FLOW VALVE SIZE GENERALNOTES 1. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICA DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NCVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NCVD29 + 3.60 FEET. 2. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. 3. SEE SHEET C501-1 THROUGH C501-1D FOR LEGEND, ABBREVIATIONS, AND GENERAL NOTES. 4. SEE PAVING AND GRADING DETAIL PLAN SHEETS C501-5A THROUGH C501-51) FOR PAVING DETAILS, HORIZONTAL CONTROL AND GRADING INFORMATION. 5. SEE STORM DRAINAGE DETAIL PLAN SHEETS C501-6A THROUGH C501-61R FOR STORM SYSTEM IMPROVEMENT DETAIL. 6. SEE UTILITY DETAIL PLAN SHEETS M501-1A THROUGH M501 -1D FOR FIRE WATER SYSTEM IMPROVEMENT DETAILS. 7. SEE CHANNELIZATION PLANS FOR PAVEMENT MARKINGS, TRANSIT FEATURES, AND SIGN IMPROVEMENT DETAIL. DETAIL REFERENCES I SYSTEM MAINLINE GATE VALVE L504 2� QUICK COUPLING VALVE L504 IRRIGATION PIPE TRENCH SECTION � L504 ® VALVE BOX INSTALLATION L504 (51 I� RAINBIRD 1800 SERIES INSTALLATION L505 © PIPE SLEEVING L504 �\ BATTERY OPERATED REMOTE CONTROL VALVE L504 IRRIGATION NOTES 1. IRRIGATION CONTRACTOR TO COORDINATE WITH THE GENERAL CONTRACTOR TO INSTALL IRRIGATION SLEEVES REQUIRED. 2. CONTRACTOR TO VERIFY STATIC WATER PRESSURE AVAILABLE AT THE EXISTING IRRIGATION MAINUNE CONNECTION PRIOR TO COMMENCING WORK. THE CONTRACTOR IS REQUIRED TO NOTIFY THE OWNER IF THERE IS INSUFFICIENT WATER PRESSURE OR FLOW PRIOR TO INSTALLING ANY IRRIGATION EQUIPMENT. 3. PIPING SHOWN ON THE IRRIGATION PLANS IS DIAGRAMMATIC FOR CLARITY. LOCATE IRRIGATION LINES IN PLANTERS EXCEPT AT SLEEVE LOCATIONS FOR ROAD CROSSINGS. ADJUST MAINLINE AND LATERAL LOCATIONS TO AVOID UTILITIES, UTILITY STRUCTURES AND LIGHT POLES. 4. COMPONENTS OF IRRIGATION SYSTEM TO BE INSTALLED AND PROPERLY ADJUSTED TO PROVIDE HEAD TO HEAD COVERAGE AND MINIMIZE OVER SPRAY ON PARKING AREAS. 5. SYSTEM TO BE DESIGNED TO PROVIDE 1/2` PRECIPITATION PER SEVEN DAY WEEK WITHIN A ONE HOUR WATER WINDOW DURING THE WARMEST AND DRIEST TIME OF THE IRRIGATION SEASON DURING THE 3 YEAR PLANT ESTABLISHMENT PERIOD. IRRIGATION SYSTEM RUN TIMES (ASSUMING 2 RUN TIMES PER WEEK) SHALL BE ADJUSTED DURING THE IRRIGATION SEASON BASED UPON EVAPOTRANSPIRATION REQUIREMENTS. 6. WATERING OF INDIVIDUAL ZONES SHALL BE COORDINATED WITH OTHER IRRIGATION ZONES ON THE SAME MAINLINE THAT ARE OPERATING WITH A SEPARATE TIMED ELECTRIC CONTROLLER. 7. SYSTEM IS TO BE WINTERIZED BY USE OF COMPRESSED AIR INJECTED AT THE QUICK COUPUNG VALVE. 8. VALVE DESIGNATION NUMBER SHALL BE CLEARLY NOTED ON EACH VALVE SUCH THAT IT CAN BE VISIBLY READ WHEN VALVE BOX LID IS OPENED. 9. CONTRACTOR IS TO COORDINATE WITH THE OWNER IN DETERMINING PROPER WATERING TIMES AND PROVIDE A DETAILED WATERING PLAN AND SCHEDULE FOR THE SUMMER MONTHS. CONTRACTOR IS TO SUBMIT PLAN TO THE OWNER FOR ACCEPTANCE PRIOR TO PROCEEDING WITH PLANTING OPERATIONS. R-4177062� IN COMPLIANCE WITH CITY OF RENTON STANDARDS "( WSP US4AC 1 3�°`�CIVIL PERMIT CALL 48 HOURS 5 M300 20 0 20 40 N Rtival Way, WA 9B0012K BEFORE YOU DIG FAX: Gi06)431-2250 1-800424-5555 FAX: ezOe)+az-zzs0 scale feet SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE tar ACCEPTABILITY DEW 07 09 21 DRAWN DATE B IRRIGATION PLAN AND NOTES N M 21ORIG APRON R - CENTRAL C780242 WSP SPT 07 09 21 THIS DESIGN AND/OR CURRENT I H KC180242 RIG 07 09//SPECIFICATION IS APPROVED DJS 07 09 21 sREnL503 L03 o Eo e oePr oA DEW 07 09 21rlTLE APRON R - CENTRAL CHECKEDAPPROVED RENTON SITE JOBNO,C180242 COMP NO, APPROVED CIVIL MASTER 11 RENTON, WA DWG NO. RTN-YD-L501-7C