LEGEND
I�
I
I
I
I
PROPERTY LINE
— W W w W W— EX. 12" WATER MAIN
WATER LINE 1
C-4.7
FIRE DEPARTMENT CONNECTION r360.2
C-4.8
�� BEND/TEE WITH THRUST BLOCKING 330.2
C-4.7
►� GATE VALVE 330.1
C-4.7
DDCVA DOUBLE DETECTOR CHECK VALVE ASSEMBLY 360.2
C-4.8
RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY 350.2
C-4.7
® DOUBLE CHECK VALVE ASSEMBLY 340.8
C-4.8
i� FIRE HYDRANT 310.1
C-4.7
3" DOMESTIC WATER METER C20:8
t)
2" IRRIGATION 320.2
WATER METER
SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
SEE SHEET C-4.3 FOR CONTINUATION
III � _7 - ---77 -7 7 7
6 LF 12" D
STA: 8+71.2
13 LF 12" D
STA: 8+56.5
SEE SHEET C-4.1 FOR CONTINUATION
WATER SCHEDULE
KEY NOTE KEY NOTE
O1 — 12" x 6" TEE (MJ x FL) 22 WITH THRUST BLOCKING 1 — 12" 45` BEND (MJ)
9
1 — 6" GATE VALVE (FL x MJ) SEE PLAN FOR STATION
1 — 12" GATE VALVE (MJ WITH SPOOL)
22 LF 6" D.I. FIRE SERVICE FIRE HYDRANT, BOLLARDS, AND ASSOCIATED
1 — FIRE HYDRANT ASSEMBLY SERVICE LINE TO BE REMOVED.
WITH THRUST BLOCKING 28 CONTRACTOR TO COORDINATE WITH BOEING
STA: 8+71.27, 22.20' RT FIRE INSPECTOR, BOEING PLUMBERS, AND
BOEING FACILITIES ENGINEERS PRIOR TO
10 1 — 12" 22.5° BEND (MJ) REMOVAL.
WITH THRUST BLOCKING
SEE PLAN FOR STATION
0 2 RECORD DRAWINGS NAVIX 09.29.22 JET
0 ® 2 RECORD DRAWINGS NAVIX 06.10.22 JET
�p Q 1 RECORD DRAWINGS NAVIX 05.17.22 JET
\� e
NO. REVISION BY DATE APPR
4a
0 15 30 60
SCALE: 1 inch = 30 ft.
ALL MECHANICAL JOINT FITTINGS AND
VALVES SHALL HAVE MEGALUG
RESTRAINT SERIES 1100 RESTRAINED
(OR APPROVED EQUAL) AND
CONCRETE BLOCKING PER COR
STANDARD PLANS
HAVIX
11235 s.e. 6th street I suite 150
bellevue, wa 98004
t: 425.453.9501 1 f: 425-453-8208
www.navixeng.com
��,I WA
6ABET
itally sign
y nelle T flin
Date:
2022.09.3
418726:sz:21- zoo.
m
ENGINEERS CONSTRUCTION RECORD CERTIFICATION
THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN
INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD
- CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR
VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD
MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT
REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY
CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE,
CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT
EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING
CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION.
NAVIX CERTIFICATION
W-412303 GeV
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURVEYED: SCALE:
Z.NALL HORIZONTAL: NAD 1983/1991 ARCO/M U RRAY
DESIGNED:
J GREEN o CITY O F TOPGOLF RENTON
DRAWN: '� RENTON
J.GREEN ONE INCH DATUM v4uvv 780 LOGAN AVENUE NORTH
CHECKED: AT FULL SCALE RENTON WA 98057
J.TAFLIN IF NOT ONE INCH Planning/Building/Public Works Dept.
APPROVED: SCALE ACCORDINGLY WATER PLAN
J.TAFLIN
DATE:
09.26.2022
FIELDBOOK:
PAGE:
C-4.2
SHEET: OF:
51 82
LAI
N
O
N
O
O
O
r
♦V♦
V
z
a
O
V
W
w
z
O
F—
z
LU
w
ILL
♦O
V
IL
O
F—