Loading...
HomeMy WebLinkAboutzW-4123SetSECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. M N r ti N F- z O F- z LU w LL J O a. O F- r` r� N N O N N Q aD Cn • C J r 0 25 50 100 r SCALE: 1 inch = 50 ft. M Cfl O O O N lie O O O O 47 r a J N O N O O O (4) r �A "'I"lX I a -ITS I CIVIL 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com ��'1WA 6ABET ?� itally sign y nelle T flin Date: 2022.09.3 0 418726:3M6:57-0 m I I ' I I II ENGINEERS CONSTRUCTION RECORD CERTIFICATION '^ rn `, v THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, S MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THENNEW CONSTRUCTION SHOWN BASED UPON OUR LEGEND PROPERTY LINE —W—W—W—W EX. 12" WATER MAIN WATER LINE 1 C-4.7 FIRE DEPARTMENT CONNECTION N�2: 41�jIT BEND/TEE WITH THRUST BLOCKING 330.2 C-4.7 ►� GATE VALVE 330.1 C-4.7 DDCVA DOUBLE DETECTOR CHECK VALVE ASSEMBLY 360.2 C-4.8 RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY 350.2 C-4.7 DOUBLE CHECK VALVE ASSEMBLY 340.8 C-4.8 i� FIRE HYDRANT 310.1 C-4.7 3" DOMESTIC WATER METER C20.48 0 2" IRRIGATION 320.2 WATER METER C-4.6 2 2 1 NO. RECORD DRAWINGS RECORD DRAWINGS RECORD DRAWINGS REVISION SURVEYED: Z.NALL DESIGNED: J.GREEN NAVIX 09.29.22 JET NAVIX 06.10.22 JET DRAWN: J.GREEN NAVIX 05.17.22 JET CHECKED: J.TAFLIN BY DATE APPR APPROVED: J.TAFLIN VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD Z MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, a CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. Q NAVIX CERTIFICATION Q W-412301 BY o IN COMPLIANCE WITH CITY OF RENTON STANDARDS V W �i z O F— z W w SCALE. DATE: VERTICAL: NAVD 1 3/1 ARCO/M U RRAY 09.26.2022 LL J 988 ® HORIZONTAL: NAD 198991 CITY OF TOPGOLF RENTON FIELDBOOK: ;R RENTON 780 LOGAN AVENUE NORTH PAGE I ONE INCH DATUM DRAWING N0: AT FULL SCALE RENTON WA 98057 C-4.0 a IF NOT ONE INCH Planning/Building/Public Works Dept. O SCALE ACCORDINGLY OVERALL WATER PLAN SHEEP: 49 OF: 82 SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. SEE SHEET C-4.2 FOR CONTINUATION N 7 Tom N C I N H 1 1 1 �: z 0 F- z LU w LL J 0 0 IL 0 F- I N U) U) 3IgI rngr ` I M .. c >P — �r - =c STA: 0+83.5 20 LF 12" DI P— 10LF6"DI M E �� I Q N LH I CONTRACTOR TO VERIFY LOCATION OF EXISTING SD LINE. cNv IF A CONFLICT WITH PROPOSED WATER LINE IS IDENTIFIED N NOTIFY THE CITY AND PROVIDE PLAN REVISIONS. cc CONTRACTOR TO VERIFY IF EXISTING BOEING HIGH PRESSURE) `V WATER MAIN PRESENTS A CONFLICT WITH PROPOSED WATER Q) MAIN. IF A CONFLICT WITH PROPOSED WATER LINE IS v' IDENTIFIED AND REQUIRES CHANGE OF PROPOSED WATER LINE THEN NOTIFY THE CITY AND PROVIDE PLAN REVISIONS. LEGEND 0 �I PROPERTY LINE -WWWWW- EX. 12" WATER MAIN 0' WATER LINE I ,I FIRE DEPARTMENT CONNECTION 360.2 C-4.8 BEND/TEE WITH THRUST BLOCKING 330.2 o C-4.7 ~ ►� GATE VALVE 330.1 i C-4.7 DDCVA DOUBLE DETECTOR CHECK VALVE ASSEMBLY 360.2 :3 -A REDUCED PRESSURE BACKFLOW ASSEMBLY 350.2 Q C-4.7 ® DOUBLE CHECK VALVE ASSEMBLY 340.8 i� FIRE HYDRANTry 14:7 3" DOMESTIC WATER METER r32.4 Q, 8 c Cn 6m 2" IRRIGATION 320.2 WATER METER m ►91 29 _ a = LF 12" DI LF 12" DI- I — 15' WATER UTILIT EASEMENT LL. I�I O 13 LF 6" DI 8 6+00 65 LF 12" Di l �I - I C 14 4 LF 12" DI EXISTING STORM — DRAIN LINE 14 TO BE 5+00 ABANDONED IN PLACE 88 LF 12" DI — � I 20 LF 2" DI 20 LF 3" DI 27+36 7 - 5 LF 12" DI 26+00 6 LF 12" DI' 3 5 c� 23+09 22 � 2 + �TA.J4+12.311 �26 LF 6" DI o 29 LF 12" DI o 0 \/h 4+00 0 2 LF 6" DI 19 LF 12" DI 12 LF 6" DI I■I IPA wk. —m mu •• CN �� • �,� 7—A OGAN AVE N -- (IS lim Fil i i i i N M M a�.. IT m WATER SCHEDULE KEY NOTE KEY NOTE KEY NOTE KEY NOTE KEY NOTE OSTD CONNECT TO EXISTING 12" WATER MAIN (CUT IN BY CITY FORCES) PER COR PLAN 300.4, SHEET C-4.8 WITH: 1 - 12" x 12" TEE (FL) 3 - 12" GATE VALVES (FL x MJ) 3 - 12" SLEEVES (MJ x MJ) WITH THRUST BLOCKING SEE PLANS FOR STATION CONTRACTOR TO VERIFY EXISTING WATER MAIN LOCATION AN D DEPTH PRIOR TO CONSTRUCTION ANY PORTION OF PROPOSED WATER MAIN EXTENSION CUT IN BY CITY FORCES AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 3 O 1 - 12" 90° BEND (MJ) WITH THRUST BLOCKING SEE PLAN FOR STATION 8 O 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 15 LF 6" D.I. FIRE SERVICE 1 - FIRE HYDRANT ASSEMBLY WITH THRUST BLOCKING STA: 6+15.59, 15.03' LT 20 1 - 3" DOMESTIC METER PER COR STD PLAN 320.4, SHEET C-4.8. INSTALL 4" x 3" REDUCER INSIDE 5' x 7' x 7' METER VAULT. STA: 25+77.07 25 1 - 2" PRESSURE REDUCING VALVE 1 - 2" BACKFLOW ASSEMBLY DCVA IN METER BOX PER COR STD PLAN 340.8, SHEET C-4.8. STA: 27+04.75 (PRV) STA: 27+10.20 (DCVA) O 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 12 LF 6" D.I. FIRE SERVICE 1 - FIRE HYDRANT ASSEMBLY WITH THRUST BLOCKING STA: 3+69.47 14.55' LT 21 1 - 3" PRESSURE REDUCING VALVE 1 - 3" BACKFLOW ASSEMBLY MOUNTED ON CONCRETE PAD IN HOT BOX PER COR STD PLAN 350.2, SHEET C-4.7. STA: 25+62.70 (PRV) STA: 25+68.45 (RPBA) 14 1 - 12" 45° VERTICAL BEND (MJ) WITH MEGALUG WITH THRUST BLOCKING PER COR STD PLAN 330.3, SHEET C-4.8. SEE PLAN FOR STATION 26 IRRIGATION POINT OF CONNECTION. SEE PLAN FOR STATION. SEE LANDSCAPE PLANS FOR CONTINUATION. O 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 1 - 12" GATE VALVE (FL x MJ) WITH THRUST BLOCKING SEE PLAN FOR STATION 16 O 1 - POST INDICATOR VALVE DOWNSTREAM OF DDCVA STA: 22+66.48 22 1 - 12 US BEND MJ WITH THRUST BLOCKING SEE PLAN FOR STATION 27 BUILDING POINT OF CONNECTION. SEE PLAN FOR STATION. SEE PLUMBING PLANS FOR CONTINUATION. 17 1 - 6" DOUBLE DETECTOR CHECK VALVE ASSEMBLY PER COR STD PLAN 360.2, SHEET C-4.8. STA: 22+74.42 23 1 - 4" 45° BEND MJ WITH THRUST BLOCKING STA: 24+17.62 " 1 - 3DOMESTIC SERVICE CONNECTION SEE PLAN FOR STATION O6 2 1 - 12" x 6" TEE (MJ x FL) 1 - 6" GATE VALVE (FL x MJ) 10 LF 6" D.I. FIRE SERVICE 1 - FIRE HYDRANT ASSEMBLY WITH THRUST BLOCKING STA: 0+61.76, 11.91' LT 24 1 - 2" IRRIGATION METER PER COR STD PLAN 320.2, SHEET C-4.6. METER TO BE INSTALLED WITH A 17" x 30" METER BOX. STA: 27+14.87 18 1 - FIRE DEPARTMENT CONNECTION STA: 22+76.49, 5.73' RT 29 O CONCRETE DEADMAN BLOCK PER DETAIL 2, SHEET C-4.7 WITH SHACKLE RODS PER C.O.R. DET. 330.5, SHEET C-4.7. 7 O 1 - 2" IRRIGATION SERVICE 1 - 2" GATE VALVE (THREADED) 1 - 12 GATE VALVE (MJ) WITH THRUST BLOCKING SEE PLAN FOR STATION 19 1 - 6" 90° BEND (MJ) WITH THRUST BLOCKING STA: 21+20.44 O 2 RECORD DRAWINGS 0 2 RECORD DRAWINGS �p Q 1 RECORD DRAWINGS \� e NO. REVISION SURVEYED: Z.NALL DESIGNED: J.GREEN NAVIX 09.29.22 JET NAVIX 06.10.22 JET DRAWN: J.GREEN NAVIX 05.17.22 JET CHECKED: J.TAFLIN BY DATE APPR APPROVED: J.TAFLIN SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF 1"R] RENTON Planning/Building/Public Works Dept. ■ 0 15 30 60 SCALE: 1 inch = 30 ft. ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE MEGALUG RESTRAINT SERIES 1100 RESTRAINED (OR APPROVED EQUAL) AND CONCRETE BLOCKING PER COR STANDARD PLANS rJ 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com " I -- BE , WA itally sign y nelle T flin Date: 2022.09.3 A 418726:3;Z:09-0 m ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. NAVIX CERTIFICATION W-412302 BY IN COMPLIANCE WITH CITY OF RENTON STANDARDS LAI O N O O z 0 F- z LU w ARCO/M U RRAY DATE:09.26.2022 J TOPGOLF RENTON O OOK: 780 LOGAN AVENUE NORTH PAGE: PAGE: DRAWING N0. RENTON, WA 98057 C-4.1 a0 WATER PLAN SHEET: 50 0F: 82 M ti N am z O H z LU w LL J O 0 IL O H A Q LH N N CD N N Q N C/") Map s I0 N CD NI 00 M o LEGEND I� I I I I PROPERTY LINE — W W w W W— EX. 12" WATER MAIN WATER LINE 1 C-4.7 FIRE DEPARTMENT CONNECTION r360.2 C-4.8 �� BEND/TEE WITH THRUST BLOCKING 330.2 C-4.7 ►� GATE VALVE 330.1 C-4.7 DDCVA DOUBLE DETECTOR CHECK VALVE ASSEMBLY 360.2 C-4.8 RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY 350.2 C-4.7 ® DOUBLE CHECK VALVE ASSEMBLY 340.8 C-4.8 i� FIRE HYDRANT 310.1 C-4.7 3" DOMESTIC WATER METER C20:8 t) 2" IRRIGATION 320.2 WATER METER SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. SEE SHEET C-4.3 FOR CONTINUATION III � _7 - ---77 -7 7 7 6 LF 12" D STA: 8+71.2 13 LF 12" D STA: 8+56.5 SEE SHEET C-4.1 FOR CONTINUATION WATER SCHEDULE KEY NOTE KEY NOTE O1 — 12" x 6" TEE (MJ x FL) 22 WITH THRUST BLOCKING 1 — 12" 45` BEND (MJ) 9 1 — 6" GATE VALVE (FL x MJ) SEE PLAN FOR STATION 1 — 12" GATE VALVE (MJ WITH SPOOL) 22 LF 6" D.I. FIRE SERVICE FIRE HYDRANT, BOLLARDS, AND ASSOCIATED 1 — FIRE HYDRANT ASSEMBLY SERVICE LINE TO BE REMOVED. WITH THRUST BLOCKING 28 CONTRACTOR TO COORDINATE WITH BOEING STA: 8+71.27, 22.20' RT FIRE INSPECTOR, BOEING PLUMBERS, AND BOEING FACILITIES ENGINEERS PRIOR TO 10 1 — 12" 22.5° BEND (MJ) REMOVAL. WITH THRUST BLOCKING SEE PLAN FOR STATION 0 2 RECORD DRAWINGS NAVIX 09.29.22 JET 0 ® 2 RECORD DRAWINGS NAVIX 06.10.22 JET �p Q 1 RECORD DRAWINGS NAVIX 05.17.22 JET \� e NO. REVISION BY DATE APPR 4a 0 15 30 60 SCALE: 1 inch = 30 ft. ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE MEGALUG RESTRAINT SERIES 1100 RESTRAINED (OR APPROVED EQUAL) AND CONCRETE BLOCKING PER COR STANDARD PLANS HAVIX 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com ��,I WA 6ABET itally sign y nelle T flin Date: 2022.09.3 418726:sz:21- zoo. m ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD - CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. NAVIX CERTIFICATION W-412303 GeV IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURVEYED: SCALE: Z.NALL HORIZONTAL: NAD 1983/1991 ARCO/M U RRAY DESIGNED: J GREEN o CITY O F TOPGOLF RENTON DRAWN: '� RENTON J.GREEN ONE INCH DATUM v4uvv 780 LOGAN AVENUE NORTH CHECKED: AT FULL SCALE RENTON WA 98057 J.TAFLIN IF NOT ONE INCH Planning/Building/Public Works Dept. APPROVED: SCALE ACCORDINGLY WATER PLAN J.TAFLIN DATE: 09.26.2022 FIELDBOOK: PAGE: C-4.2 SHEET: OF: 51 82 LAI N O N O O O r ♦V♦ V z a O V W w z O F— z LU w ILL ♦O V IL O F— SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. Z O H Z W w U. ♦O V IL O F- Q LH I N N CD N N Q C/-) CD w U) 0 N / 0 c� CD- 0 0 0 Q / 0 N ry / 0 o� c Cn 0 MAP STAI 19+75.7 15 .71 20�+-III -6E) 1 60 LF12"nl STA: 19+38.6 STA: 19+25.08 ISTA: 19+34.97 STA: 19+2. 3: I I // I 0 Cn a a I � S^ SC S II I N M I 14+03 CAP FOR FUTURE DEVELOPMENT I o 12 I t 34 LF 12" DI I U' Io L 24 LF 6_ DI z o I -T 13 13 I I ❑ I I 0 I I I I 93 LF 12 DI I I - - ❑ � 13+00 I o cc__ STA: 12+68.5 D z STA: 12+73.1 w D- :2 ww I I I-- w I � 16+50 � 23 LF 12" DI �:�p 14 I , �I SS /-19+00 /-18+00 17+00-\ STA: 16+60.09\ - SS SS-c 0 0 m II 14 STA: 12+81.2 STA: 12+77.7 ` II \12 00 . I 92 LF 12" DI 15' WATER UTILITY J Ii i EASEMENT S Q LEGEND SEE SHEET C-4.2 FOR CONTINUATION - - PROPERTY LINE WATER SCHEDULE -WWWWW- EX. 12" WATER MAIN KEY NOTE WATER LINE 1 1 - 12" x 12" TEE (FL x FL) C-4.7 11 3 - 12" GATE VALVE (FL x MJ) 360.2 WITH THRUST BLOCKING FIRE DEPARTMENT CONNECTION C-4 8 STA: 12+43.92 4�j� BEND/TEE WITH THRUST BLOCKING 330.2 12 1 - 12" x 12" VERTICAL CROSS FOR C-4.7 POLYPIGGING PER COR STD PLAN 300.6, 330.1 SHEET C-4.8. ►� GATE VALVE C-4 7 WITH THRUST BLOCKING SEE PLAN FOR STATION 360.2 1 - 12" x 6" TEE MJ x FL DDCVA DOUBLE DETECTOR CHECK VALVE ASSEMBLY C-4.8 13 1 - 6" GATE VALVE (FL x MJ) 27 LF 6" D.I. FIRE SERVICE -A REDUCED PRESSURE BACKFLOW ASSEMBLY 350.2 1 - FIRE HYDRANT ASSEMBLY C-4.7 WITH THRUST BLOCKING ® DOUBLE CHECK VALVE ASSEMBLY 340.8 STA: 13+70.41, 26.40' RT C-4.8 i� FIRE HYDRANT 310.1 C-4.7 3" DOMESTIC WATER METER �20:8 0 2 0 ® 2 � 2" IRRIGATION 32p.2 �ae� 1 WATER METER NO. KEY NOTE 14 1 - 12" 45° VERTICAL BEND (MJ) WITH MEGALUG WITH THRUST BLOCKING PER COR STD PLAN 330.3, SHEET C-4.8. SEE PLAN FOR STATION RECORD DRAWINGS RECORD DRAWINGS RECORD DRAWINGS REVISION 0 15 30 60 SCALE: 1 inch = 30 ft. ALL MECHANICAL JOINT FITTINGS AND VALVES SHALL HAVE MEGALUG RESTRAINT SERIES 1100 RESTRAINED (OR APPROVED EQUAL) AND CONCRETE BLOCKING PER COR STANDARD PLANS nJ 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 I f: 425-453-8208 www.navixeng.com ��'16ABET v R� pF WASgI�� � j itally sign y�F- gnelle T flin Date: 9UUUU 2022.09.3 fin\ 0 418726:3Z:34-0' ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN 1 INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD - CONDITIONS OF THE NEW CONSTRUCTION SHOWN BASED UPON OUR KEY NOTE CONNECT TO EXISTING 12" WATER MAIN (CUT 15 IN BY CITY FORCES) PER COR STD PLAN 300.4, SHEET C-4.8 WITH: 1 - 12" x 12" TEE (FL) 3 - 12" GATE VALVES (FL x MJ) 3 - 12" SLEEVES (MJ x MJ) WITH THRUST BLOCKING CONTRACTOR TO VERIFY EXISTING WATER MAIN LOCATION AND DEPTH PRIOR TO CONSTRUCTION OF ANY PORTION OF PROPOSED WATER MAIN EXTENSION CUT IN BY CITY FORCES AND NOTIFY ENGINEER OF ANY DISCREPANCIES. SURVEYED: Z.NALL DESIGNED: J.GREEN NAVIX 09.29.22 JET NAVIX 06.10.22 JET DRAWN: J.GREEN NAVIX 05.17.22 JET CHECKED: J.TAFLIN BY DATE APPR APPROVED: J.TAFLIN SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVE) 1988 HORIZONTAL: NAD 1983/1991 DATU M VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. NAVIX CERTIFICATION W-412304 BY IN COMPLIANCE WITH CITY OF RENTON STANDARDS Z O Z LU ARCO/M U RRAY DAB 09.26.2022 J CITY OF TOPGOLF RENTON FIELDBOOK: •"vv RI RENTON 780 LOGAN AVENUE NORTH DRAWING NO: Planning/Building/Public Works Dept. RENTON, WA 98057 C-4.3 a0 WATER PLAN SHEET: 52 OF: 82 SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. YAW N N O N N Q N C/") G N ry / 0 cn LAI N O N O O O (4) r z O I- z NW w LL J O O H SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. E Q C0 YAW N N O N N Q N C/") • G N ry / 0 cn LAI N O N O O O (4) r V 0 Z z O I- z NW w LL J O O H SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. M N TM I fti N I Z 0 Z W U. J 0 0 Q Ib N-) Ln I C "i N O N N Q CD Cn • • CD w U) i-) c i7 0 N / O C-D n F- 0 O U Q c 0 C OJ CC / c 0 C c- Cn 0 / E WATER PLAN GENERAL NOTES Standard P160 No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE-COAISTRUCTJON CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONMILICFION. 2, ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING FXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM 4MPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG COTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CrrY OF RENTON PRIOR TO BRINGING ANY MATERIAL5 ON -SITE. 4, ALL WATER MAIN PIPE MATERIALS SHALL 13E CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWAC 151 AND C 104, PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 9-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 35 INCHES FOR PIPE DIAMETER OF i0-INCH OR LESS AND 49 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST RE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS ANDTO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALLTRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MOD. 5. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS JOR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDTnoN TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPESAND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM I'MORTO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALLAND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TEMNG. 8, NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BETAKEN FOR PURITYTESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THEEXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION- Ti-IE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SNORING, AND ALL MATERIALS REQUIRED FOR THE CFFY OF RENTON TO PERFORM THE CONNECTION TO THE EX"NG WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. STD. PLAN - 300.0 PUBLIC WORKS WATER PLAN GENERAL NOTES DEPARTMENT MARCH 2010 1r T ,2" �ND 2" WATER SERVICE DETAIL 0. 11 N: VALVC DOx sHOULV NOT RCST ON PIPE LATER COMPACTION IN AREA DF VALVE BOX COULD CAUSE THE BREAKAGE OF THE SERVICE. 2 x 7,-l7_Lni rl 9 A - A DRILL 2' 0A. HOLE FOR TOUCHREAD DEVICE 2-1/2" MIN- rROLI NEAREST AND FRONT EDOF OF PIT LID TMkL RIB-� •1GY Ill.) RTY I FMC I � w 1N LOMPROVED " RIGHT -Of -WAY INSTALL METER 80X AT PROPERTY LINE WIT1t at2' LONG COPPER TAILPIECE u a }" WIN. 12 MAX. LL s ¢w LEAVE EXPpSEi] v o n n 72 BY PASS NOT ALLOWED FQR IRRIGATION METERS j / �7 f 13 Q CRk15a-LED ROCK eASE TO SUPPDRT VAU L T- DUMK-JOINT GOUPLIRG x MIPT CAST IRON OR CUCTILE IRON WATERMAIN NOTE; THE CENTER OF THE HOLE MUST 9E AT LEAST t- FROM UNDERNEATH RIBS UNLESS THE R10SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB, PRNATE PIPIN-i MATERIAL IJST. FOR 2" SERVICE= METER 1-0CATEU IN PLANTING STRrP, MATERIAL LIST FOR 1-T &- SERVICE: METER LOCATED IN PLANTING STREP BETWEEN CURD do SIDEWALK BETWEEN CURB & SIDEWALK 1 2' topped Lee, on now wotaer maw t. 2' topped tee on new water main. 2. 4- long X 2" brass nipple worn tnreadea ends (MIPT). 2. 4- long X 2' brass nipple with threaded ends (MIPT), 3. 2' resirient scot gate valve with threaded ends, eRuare operating nut, 3. 2' roilloht snot gate vulva with threaded ends, squgrs oparahsg not, and d wolye nut exLmsion II required (see standard delal 3M-I). valve nut iwLensiad n If required (see stonard detall 330.1) - an 4- 4-o Pi-q? cast iron -1- box. Stpndgrd B" top section with regular 4- Tw❑ picte coat iron valve box. Stpnaard B' top icctian with rtlular ease base secLlan, length to fit. 'lug" type cover, 2" brass buohing (MIPT x sectloi, length ka fit. 'lug' t}pe cover. FIPT), 5. 2- X 1-1/2' hers brow bushing (MiPt x FIPT), 2 each 1-1/2` proves or i. 2 each 2' brass or braa2t nipples 5" length. threaded ands, 2 each tnon=e nipples 6" length, threaded ends. 2 each b-- pr 2:-40' Grass or bronze ulbowa {FIPT x FIPT). bronze Obaws (FIPT x FIPT). 6. 2(MIPT) a compression fitting, Ford C84-86 or equal. S. 1-1/2' (MIPT) x oampression ftiing. Ford C94-66 or squat, 7. 2" soft copper tubing lyprr K gr brg55 nipples (MIPT c MIPT), rehgth 1. 7. 1-1/2" aalL tappyv tubing type K ne brass nipples (MIPT y MIPT), length F.. to fit. B. 2" threaded brow 9D' ell. S. 1-1/2" threaded brass 9O' all. for Ford L44-77 or equal. 9. 2" Cuatbrnaettsr with 1sy-pass Ford: 1-19H 5a-i29-11-77 be Si-3/1t1' 9. 1-1/2" Cuelomsetter with by-pass Fars: VBH 86-129-11-65 ), Mt ID6nDld Bross 308715WOFF775 to M-1Jer 8-1427-2', wHh flanged 13 3/16-), MrD hold Brass' W8612WOFF1665 or Mueller 13-1427-1 1/2" ongle boll vnlwe and padroCk wings on fnIaL, and ortgle Check valve wllh iigng�d ongla boll votVe and pPdlagk wings on inlet, and ongle GnF!.:E outlet, .boll -W on bypass with padlock wings Luetomdetter sha11 valve nullei, ball yaTVe an bypass with pddlnck wing, Gu5temxtter shu!I hove Vertical inlet and outlet. taove verticor inlet and outlet. 10. 121gid matw spreader to bd supplied arid inetalleA In meter sailer by 10. J31gld rnotllr apreadar to tie supplied and 1+1ate11ed In meter getter by contractor can trq�tor. 11- Water rneier shall be supplied and Instalied by My oI Renton upon IT. Wnier meter Shall be supplied and Installed by City of Realm upon payment of off related water metar tee and satlsfoctary pressure and payment ai all related water meter faa ana satlsfaatory preseura and purity tea Le. purity tests. 12. 17"x30" Plastic meter box equal to Mld-States PlasLim Inc- BCF Seflas 12. 17"x30- Plastic meter lox equol to Mlfl-States Plnstics. Inc. BCF aeries MSBCF 1730-18 ,kith 2- thick Duatile Iron diamond pigte cove is-x31- MSDGF 17$0-1B with 7- thicA puntle vcn digmgnd place cgwer 1Jd`x31r ewal to Mid -States Plastics. Inc. MSC&C-1730-R wrth 2' drilled hole equal to Mid-5Latea Plastics, Inc, MSCeC-173O-A with 2" dril':ed table for for touphread pit lid, and meter read Ild. taudlread pit hd. 13, 2' coupling Ccompression x FIPT) with 2' plug (U PT). Ford 0-14-66 13. 1-112- coupling (comprassion x FIPT) with 1-1/2' plug (MIPT), Fora nr egucll. The property firmer ie responsible for any naceasory adaptation or C-14-66 ar equal. The property Dwner Is responsible fur any necessary cxtensian of water service. adgutation or extension of water serwlce- NxTE: ALL METER UDXES INSTALLED IN CONCRETE CAR PAVED DRJVEWAYS SHALL BE CAST-IRON EQ1JAL TO OLYMPIC FOUNDARY. EXPANSION JOINT'S MUST eE INSTALLED 12" MINIMUM CW BOTH SIDES OF METER BOX. Y `• PUBLIC WOFKS 1 12' AND 2" WATER SERVICE LOCATED STD. PLAN - 320.2 } -# DE"PART;uENT IN PLANTING STRIP _ �•,; , MARCiI 2010 Utility Specifications Water Utility Notes and Specifications THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WATER UTILITY. 1. All work rnateriai 0all be in conformance with the standards and specifications of the City of Renton Planning/Building/Public Works Department and the latest edition of the WSDOT/APWA Standards and Specifications, as approved and modified by the City of Renton in the Renton Standard Plans & Specifications. A set of approved plans shall be kept on site at all times during construction. 2. The hours of work in the street right of way shall be limited to 8:30 AM to 3:30 PM on weekdays unless otherwise approved in writing by the Public Works Department at (425) 430-7301. The Police Department, Fire Department, and 911 shall be notified 24 hours in advance of any work in the right of way, 3. All locations of existing utilities shown are approximate and it shall be the contractor's responsibility to verify the true and correct location so as to avoid damage or disturbance. For utility locates calf 48-hour locators 800-424-5555. 4. An approved Traffic Control Plan is required to be submitted at the Pre -Construction meeting. 5. datum far Vertical Control shall be North American Vertical C7atum 1988 Meters, and for Horizontal Control shall be North American Datum 1983,l1991 Meters unless otherwise approved by the City of Renton Public Works Department. Reference benchmark and elevations are noted on the plans. 6. All watermain pipe is to be cement lined ductile iron pipe conforming to AWWA C110 and C I I I or latest revision, thickness Class 52. Cement mortar lining and seal Coating shall conform to AWWA C104 or latest revision. Pipe joints to be push -on or mechanical joint. Bedding to be Class C. All ductile iron pipe and fittings shall be polyethylene wrapped per ANSI/AWWA C105/A21.5-93 Standards. 7. Cast iron and ductile iron fittings shall be cement lined, pressure rated as noted on plans, and in accordance with ANSI/AWWA C110/A21.10-87. Cement lining shall be in accordance with ANSI/AWWA C104/421/4-90, If fittings are 3 to 12 inches in diameter and have mechanical joints, the fittings shall in accordance with either ANSI/AWWA C110-A21.10-87 or ANSI/AWWA C153/A21,53-94. Three (3) inch to 12 inch diameter fittings, which have mechanical joints and/or Flanged joints, shall be in accordance with ANSI/AWWA C110/A21.10.87 or a combination of ANSI/AWWA C110/A21.10.87 and ANSI/AWWA C153/A21.53-94 such that the portion of the fitting with a mechanical joint(s) may be with ANSI)AWWA C153/A21.53-94 and that portion of the fitting with flanged joints) shall be in accordance with AWWA C110/A21.10-87. Acceptance testing in accordance with section 53.53 of ANSI/AWWA section 10-4.3 of ANSI/AWWA C110/A21.10-87 shall be obtained by the contractor and transmitted to the owner. 8. Gate valves shall be iron body, bronzed -mounted, double disc with bronze wedging device and O-ring stuffing box (AWWA C500) Or Of resilient seated type (AWWA C509). Utility Specifications Valves shall be designed for a minimum water operating pressure of 200 psi. Gate valves shall be Clow List 14, Mueller Company NO. A2380 or M & H. 9. Fire hydrants Shall be Corey type (opening with the pressure) or compression type (opening against pressure) Conforming to AWWA C-502-85 with a 6 inch mechanical joint inlet and a main valve opening (M.V.O.) of 5-1/4 inch, two 2-1/2 inch hose nozzles with National Standard Threads 7-1/2 threads per inch and one 4 inch plumper nozzle with the new Seattle Pattern 6 threads per inch, 60 degrees V. Threads: outside diameter of male thread 4.975 and root diameter 4.6263. Hydrants shall have a 1-1/4 Inch pentagon operating nut opened by turning counter clockwise (left). 10. The two 2-1/2 inch hose nozzles shall be fitted with cast iron threaded caps with Operating nut of the same design and proportions as the hydrant stem nut. Caps shall be fitted w 1th suitable neoprene gaskets for positive water tightness under test pressures. 11. The 4 inch pumper nozzle shall be fitted with a Storz adapter, 4 inch Seattle Thread x 5 Inch Storz. Storz adapter shall be forged and/or extruded 6061-T6 aluminum alloy, hardcoat anodized. Threaded end portion shall have no lugs and two set screws 180 degrees apart, Storz face to be metal, no gasket to weather, Storz cap to have synthetic molded rubber gasket, and shall be attached to hydrant adapter with 1/8 inch, coated, stainless steel, aircraft cable. 12. Fire hydrants shall be painted with two coats of paint. Preservative paint number 43- 655 safety yellow or approved equal, 13. Pumper connection to fate roadway assembly. 14, Fire hydrants shall be installed per City of Renton Standard Detail for fire hydrants, latest revision. 15. All watermains 10 inches and smaller to maintain a minimum cover of 36 inches below finish grade. All watermain 12 inches and larger shall he at a minimum of 48 inches below finish grade. Where utility conflicts occur, watermains are to be lowered to clear. 16. All watermains 6 inches and larger in diameter shall be cleaned with pipe cleaning "PIGS" prior to disinfection. The "Poly pigs" shall be Girard Industries Aqua Swab -AS or approved equal, 2 lb/cu. ft. density foam with 90A durameter urethane rubber coating on the rear of "PIG" only. 17. "PIGS" shall be cylinder shaped with bullet nose or square end. The contractor will perform the cleaning operation. 18. All watermains and services shall be pressure tested to a minimum of 200 psi or 150 psi over operating pressure, in accordance with the specifications of the City of Renton and the Washington State Health Department. All pressure testing shall be done in the presence of a representative of the City of Renton. The quantity of water lost from the main shall not exceed the number of gallons per hour as listed in City of Renton Utility Specifications Standard Plans & Specifications 7-11.3(11). The loss in pressure shall not exceed 5 psi during the 2 hour test period. 19. All watermains and services shall be disinfected by the injection of a 50 ppm (minimum concentration) chlorine/water solution. Dry Calcium Hypochlorite shall NOT be placed in the pipe as laid. Chlorine shall be metered/injected in accordance with Section 7- 11.3(12)F or 7-11.3(12)F of the Standard Specifications referenced above, 20. A pre -construction conference is required prior to any construction. A minimum of five (5) working days notice is required for scheduling. 21. Twenty-four (24) hours notice will be required prior to starting new construction. 22, It shall be the contractor's responsibility to secure all necessary permits prier t0 starting construction. 23, Installation of corporate stops, water services, lines and meters shall not be done until all service agreements, meter applications, construction permits, and payment of fees have been made to the City of Renton. 24. All connection to existing mains is to be accomplished by the City of Renton, except wet taps, which may be made by approved wet tap contractors with prior approval from the Public Works Department. All necessary excavation and materials are to be supplied by the contractor and be on -site prior to City notifications, 25. Inspection will be accomplished by a representative of the City of Renton. It shall be the contractor's responsibility to notify Development Services twenty four (24) hours in advance of backfiiling all construction. The contractor, as well as the engineers, shall keep as -built drawings. 26. Contractor to provide plugs and temporary blow -off assemblies for testing and purity acceptance prior to final tie-in. 27. All joint restraint systems (shackle rods, nuts, bolts, etc.) shall be as manufactured by the Star Manufacturing Company of Columbus Ohio, or equal, approved in writing by the Public Works Department, 28. Asphalt and concrete street paving shall be sawcut to a minimum depth of two (2) inches. Oil mat streets may be spade cut. All surface concrete, pavement, sidewalks, curb, gutters, and driveway approaches shall be sawcut to a minimum depth of two (2) Inches Or removed to an existing expansion joint. 29. A temporary cold mix asphalt patch shall be placed on the day of initial excavation with a permanent, sealed patch to be placed, to City of Renton policy, within 10 days. Call for subgrade inspection prior to placement of final patch. 30. For City projects such as telemetry conduit, the PVC pipe used shall be All chemical process lines shall be schedule 80 PVC pipe. Schedule 40 in unimproved areas and schedule 80 PVC pipe under improved areas. it O O O O 1 r a M J N O N O 40 1 r NAVIX a 'ITF I CIVIL 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 I f: 425-453-8208 www.navixeng.com �LI6ABET v R� WASgI�I i itally sign '.-bylvenelleT flin Date: U 2022.09.3 0 418726:3,9:19-0 ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. Q NAVIX CERTIFICATION NQ Ii -412307 W BY 0 V IN COMPLIANCE WITH CITY OF RENTON STANDARDS W 5, Z 0 I- Z LNU I.L SURVEYED: SCALE: DATE: VERTICAL 1988 Z.NALL HORZONTAL::NAD D1983/1991 ARCO/M U RRAY 09.26.2022 J DESIGNED: 1PRI CITY OF FIELDBOOK:2 RECORD DRAWINGS NAVIX 09.29.22 JET J.GREEN TOPGOLF RENTON 0a 2 RECORD DRAWINGS NAVIX 06.10.22 JET DMWJ.GREEN RENTON 780 LOGAN AVENUE NORTH PAGE: ONE INCH DATUM • (�Q DRAWING N0: 1 RECORD DRAWINGS NAVIX 05.17.22 JET CHECKED: AT FULL SCALE RENTON WA 98057 C'4.6 a J.TAFLIN IF NOT ONE INCH Planning/Building/Public Works Dept. O NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY WATER NOTES & DETAILS SHEET: OF: J.TAFLIN 55 82 SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. N r N ^I li I- 7151' i 0�44 Q 00 N-) LC� I N N CD N N Q N cn c C/) 0 w 120 VOLT ELECTRICAL OUTLET FOR J I HEAT TAPE. INSTALL HEAT TAPE } FOR FREEZE PROTECTION CENTER BACKFLQW PREVENTER IN 0 REDUCED PRESSURE ENCLOSURE ISACKFLOW A5;SFM13LY (RPBA) 3e MIN. � a 3" MIN INSULATED ENCLOSUR 3" MIN. 'HOT BOX" OR EQUAL 3/8" X 4" ANCHOR BOLTS PER MANUFACTURER ''•, `° I 3" MIN, CONCRETE SLAB UNION FINISHED GRADE CN FINISHED GRADE � r Z" . ` bIRAIN !2� SEE NOTE 4 6" MINIMUM SLEEVE FREE DRAINING (TYP.) GRAVEL CONNECT TO N WATER METER IMMEDIATELY ADJACENT TO RPBA FLOW INSTALLED W/ APP'D. TO OWNERS ELECTRICAL PANEL. FRONT VIEW MATERIAL PER UPC DIRECT OL)RIAL OR IN RIGID METER SIDE (SIZE AS REQ.) CONDUIT PER ELECTRICAL SIDE VIEW PERMIT REQUIREMENTS. NOTES: 1, ALL REDUCED PRESSURE BACKFLQW ASSEMBLIES (RPBA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOw PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE RPBA AND PIPING, THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE RPBA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE RPBA MUST BE TESTED BY A STATE CERTIFIED BACKFLQW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTLITY ENGINEERING DEPT,, ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALSIT, FAX NO. 425-430-7241. 4. DRAIN SHALL BE SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL MANUAL STANDARDS 3" DRAIN FOR 1" OR SMALLER RPBA's, 4" DRAIN FOR 1.5" TO 2" RPBA's, 6" FOR 3" RPBA`s. 5. RPBA AND ENCLOSURE SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. `+ PUBLIC WORKS REDUCED PRESSURE BACKFLOVV STD. PLAN - 350.E DEPARTMENT ASSEMBLY IN HOT BOX MAxch 2010 w 0. 11-1/4• BEND 22-1/2" BEND 45' BEND F., 1 CAP TEE 90' BEND THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NDTES) FOR HORIZONTAL AND DDYMWARD VERTICAL BENDS SOIL FIRM SILT OR FIRM SALTY SAND C04IPAGT SAND U(NPACT SAND & GRAVEL 90' 45, SEND 11 1 /4' 90' 45' BEND 11 1 /4" 9V 45' BEND 11 1/4- FITTING BENCI TEE CAP OR PLUG & 22 1/2' VEND TEE GAP DR PLUG & 22 1/2' EIND TEE CAP OR PLUG 22 1/2' BEND SEND BEND 4 7.0 4.2 4.2 1.7 2;9 2S 2.T 1,0 2.2 1.fi ,6ILP 6 13.3 9.4 9.4 3.8 8.7 4.7 4.? S.3 5.0 3.5 3:5 1.4 B 23_S 16_ 16.7 8.7 11_ 7 8.4 $4 3.4 8.8 6.3 8.3 ?.S 13' 53.0 37.5 37.5 t5.0 2&5 I$.B 1 18.8 75 20:0 14_0 14.0 5A AREAS CALCULATED ON 300 PSI TEST PRESSURE. 3'-Q" MEN COVER FOR WATERMAIN LESS THAN 12 S'-V" MIN, COVER FOR WATERMAIN 12" p'R GREATER, MAX. HEIGHT OF THRUST BLOCK (FT) = 0.5 Y DEPTH OF TRENCH MIN. HEJGIIT OF THRUST BLOCk (FT) = D.9, RIPE f 1,0' THRUST BLOC[ BE. AREA REFE115 TO ' FACE OF BLOCK M: IN 5QUAAU rttT NQTE-9-,- 1. LOGATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES DIFFERENT THAN SHOO SHALL BE DETERMINED BY THE ENGINEER. 2, ALL 9LOCKING SHALL BE POURED IN PLAC1' AGAINST ONDIS71JR13E1) NATIVE GROUND S ALL POURED THRt1ST 9L0CI(S SHALL NZ HACKFiLLEI} AFTER MIN. 1 DAY. PRESSURE TESTINr SHAH. OCCUR AFTER CONCRETE HAS REACHED N041INAL COMPRESSIVE $TRENGTH. 4_ ALL BLOCKING SHALL BE CONCRETE CL 5 (1-1/21. 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTNG SURFACE AWA POSSIBLE, RUT SHALL 140T COVER OR ENCLOSE DELL ENDS, JOINT BOLTS OR CLODS REASONN31LE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. CONCRETE BLOCKING FOR STD. RAN - 330.2 r + PLiDLIC WCi1t]:S HORIZONTAL AND DOWNVVAR❑ DEPARTMENT VERTICAL BENDS • V, 4tAlZCH 2010 A A PLAN VIE~ �(WAT R VALVE BOX LID WITH :> EARS IN DIRECTION 01 2" SQUARE WATER MAIN AND WORD OPERATING NUT "WATER" CAST INTO IT 12" MIN. 16, MAX, 4" CONCRETE COLLAR FOR VALVES IN PAVED AREAS 4-1/4" DIA. 12' 1/8" MIN. THICKNESS SEE DETAIL- 2 PIECE CAST IRON VALVE BOX, RICH-SEATTLE TYPE OR OLYMPiC FOUNDRY T" STEEL l� LENGTH AS REQUIRED 18" MIN, THICKNESS 2-1/4' r INSIDE MEASUREMENT 2-1/4 DEPTH SECTION A -A VALVE QPFRATINC NUT EXTENSION VALVE OPERATION NUT EXTENSION NOTE: EXTENSIONS ARE REQUIRED WHEN VALVE NUT 15 MORE THAN THREE (3) FEET BELOW FIN6HED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT LONG. ONLY ONE EXTENSION} TO BE USED PER VALVE. NOTE- ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED A5 NOTED, AND PAINTE1a WITH TWO COATS OF METAL PAINT. VALVE MARKER NOTES; VALVE MARKERS SHALL BE EQUAL TO CARSONITE UTILITY MARKER VALVE MARKER POST TO BE USED FOR ALL MAIN! LINE VALVES OUTSIDE PAVED AREAS 3$" MIN. WI DTH 62" I '1 - .24" VALVE MARKER POST WHITE PC + PUBLIC WORKS VALVE BOX, MARKER & OPERATING STD. PLAN - 330.1 DEPARTMENT NLJT EXTENSION MARCH 2010 Where shown on the plans or in the specifications or required by the Engineer, joint restraint system (shackle rods) shall be used. All joints restraint materials used shall be those manufactured by Star National Products, 1323 Holly Avenue, PO Box 258, Columbus, Ohio 43216 unless an equal alternate is approved in writing by the Engineer. Materials Steel Twes: High strength low -alloy steel (cor-ten), ASTM A588 heat -treated. 1. Tiebolt: ASTM A588, Grade B, Cor-Ten, equal to SuperStar Tielbolt Installation: SST 7 5/8" for 2" and 3" mechanical joints (M.J.) with eye for 5/8" rod Install the joint restraint system in accordance with the Manufacturer's SST 7 : 3/4" for 4" to 12" M.J. with eye for 3/4" rod instructions so all joints are mechanically locked together to prevent joint SST 756 : 3/4" for 14" to 24" M.J. with eye for 3/4" rod separation. SST 747 : 3/4" for 4" to 12" M.J. with eye for 7/8" and 1" rod Tiebolts shall be installed to pull against the mechanical joint body and SST 73/4" for 1 to M.J. with eye for and 1" rod not the M.J. follower. Torque nuts at 75-90 foot pounds for 3/4" nuts. . SST 778: 1' for 30" too 36" M.J.Mwith eye for 1" roodd 2.Tienut: Hex Nut Install tiecouplings with both rods threaded equal distance into ASTM A588, Grade B, Cor-Ten, equal to SuperStar Tienut tiecouplings. Arrange tierods symmetrically around the pipe. SS8 for 5/8", 3/4", 7/8", 1" Tiebolt and Tierod Where a Manufacturer's mechanical joint valve or fitting is supplied with 3. Tiecoupling with Tiestop Pin slots for "T' bolts instead of holes, o flanged valve with a flange by ASTM A588, Grade B, Cor-Ten, equal to SuperStar Tiecoupling mechanical joint ado for shall be used instead so as to provide adequate P P q SS10 for 5/8", 3/4", 7/8", 1" Tierod space for locating tiebolt. 4. Tierod: Where a continuous run of pipe is required to be restrained, no run of Continuous threaded rod for cutting to desired lengths restrained pipe shall be greater than 60 feet in length betwee fittings. ASTM A588, Grade B, Cor-Ten, equal to SuperStar Tierod Insert long body solid sleeves as required on longer runs to keep tierod SS12 for 5/8", 3/4", 7/8", 1" lengths to the 60 foot maximum. Pipe used in continuously restrained runs shall be mechanical joint pipe 5. Tiewasher and tiebolts shall be installed as rod guides at each joint. ASTM A588, Grade B. Cor-Ten, equal to SuperStar Tiewasher SS17 for 5/8", 3/4", 7/8", 1" round flat washer Pipe Size Inches Test Pressure PSI 2 4 6 Number and Size of Rods 8 10 12 14 24 2 250 314" 3 250 3/4" 4 250 3/4" 6 250 3/4" 8 250 3/4" 10 250 3/4" 12 250 3/4" 14 250 3/4" 16 250 3/4" 18 250 3/4" 20 250 314" 24 250 3/4" 3D 200 3/4" 33 200 1" 42 20O 1" 48 200 1" 2 5 3 4 1 �ZY STD. PLAN - 330.5 PUBLIC WORKS SHACKLE RODDS �Nzo� DEPARTMENT AND TIE BOLTS MARCH 2O10 2 RECORD DRAWINGS O 2 RECORD DRAWINGS �Q 1 RECORD DRAWINGS e NO. REVISION FIRE HYDDRANT SHALL BE COREY-TYPE EQUAL TO IOWA F-511D OR COMPRESSION TYPE SUCH AS CLOW MEDALUON, M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS FACER WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALUE OPENING, TWO 2-1 f2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4' PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STURZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY-M40RE/PT2ESERVATIIVE PAINT Nc. 5780-553 OTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE USED IF REOUIRED_ 3 20� i.tJNGRETE � � ' �rr THRUST BLOCK T 16" x 8" x 4' MININUM CONCRETE HEARING BLOCK UNDER HYDRANT MIN. 1B" TO 20" BEHIND BACE OF CURB OR 12" BEHIND BACK OF 511DEWALK THAT 15 ADJACENT TO CURB 4.075" x .5' STORZ -5'x5'x6" THICK CONCRETE PAD AROUND HYDRANT. FINISH TO MATCH FJOEWALK. EXPANSION JOINT AT BACK OF SIDEWALK CONCRETE SIDEWALK PLANTING STRIP h 36" MIN COVERn TWO-PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER, EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8' TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT EXTENSION AS REQUIRED, RAISED PAVEMENT MARKER TYPE 08-A STIMSONITE TWO-WAY BLUE REFLECTIVE CONCRETE BUCKING MAIN LINE TEE. WTH 6" FLANGE SIDE OUTLET. 5" GATE VALVE (FL X MJ) AWWA C-5D9, RESILIENT SEAT 6 DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 2-3/4" COR-TEN STEEL TIE RODS- 1/2 YARD OF 1-1/4" WASHED DRAIN RQCX 1' ABOVE BOOT FLANGE, PLACE 8 MIL POLYETHYLENE FILM AROUND TOP AND SIDES OF GRAVEL FIRE HYDRANT ASSEMBLY LEVEL ALL GRi]UNB LEVEL ALL GROUND WN 3' RADIUS IN 3' RADIUS ONE MAN ROCK I _ B ti 6" CONCRETE PAD �5' CONCRETE PAD CUT FILL HYDRANT LOCATION IN CUT OR FILL # PLJ13LJC WORKS 'FIRE HYDRANT ASSEMBLY STD. PLAN - 310.1 DEPARTMENT iAA,iRC:H 2010 SLOPE TRENCH SIDES PER OSHA REQUIREMENTS DETECTABLE MARKING TAPE 12" TO 18" BELOW FINISHED GRADE ALL WATER PIPE SHALL BE DUCTILE IRON CLASS 52 WITH POLYWRAP CONFORMING TO AWWA C110 AND C111 AS DEFINED BY WATER UTILITY NOTES AND SPECIFICATIONS NOTE 6 UNLESS OTHERWISE NOTED. COMPACTED BACKFlLL 12" 12" MIN IN TOP SECTION VIEW NOT TO SCALE , 18" 1n 1 L J 4' NOTES: 1. CONCRETE SHALL 3000 P.S.I. READY MIX POURED IN PLACE. 2- REINFORCED BARS SHALL BE DEFORMED BARS AND TIED TOGETHER. 3. FORMWORK AT FACE OF ANCHOR WALLS MUST BE REMOVED. BACKFlLL AT FACE OF ANCHOR WALL MUST BE COMPACTED TO 95X MAX DRY DENSITY BASED ASTM D1557 PRIOR TO REINSTATING SERVICE OF THE WATER MAIN. ELEVATION VIEW CONCRETE DEADMAN BLOCK TRENCH BACKFlLL SHALL CONFORM TO SECTION 9-03.19 OF WSDOT STD SPECS WATER PIPE PER PLAN PIPE BEDDING SHALL CONFORM TO SECTION 9-03.12(3) OF CO WSDOT STD SPECS I � I SELECT FILL: MATERIAL SHALL BE FREE \-COMPACTED NATIVE SUBGRADE OF LARGE ROCKS (3"+) AND SHALL BE MAXIMUM WIDTH OR COMPACTED FILL. PLACED IN 6" MAX LOOSE LIFTS AND COMPACTED TO 90% OF MAX. DENSITY =GREATER OF 30" PER MODIFIED PROCTER TEST (ASTM D1557) OR 1.5 D + 18" TYPICAL WATERMAIN TRENCH AND BEDDING N TS N TS V/4 REBAR AT 8" ON CENTER WITH 18O' STANDARD HOOKS 0 BOTH ENDS N N O O O 1 d� r CIVIL 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 I f: 425-453-8208 www.navixeng.com 6A 1 B E �F WASHI�� a itally sign ���jj'���� y nelle T flin Date 79�'�.7r 2022 �� UU 2022.09.3 .,pb 18722E U:30- 7�00' oI;: '8ION�AL ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR Z VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, a CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. Q NAVIX CERTIFICATION Q W-412308 BY o V IN COMPLIANCE WITH CITY OF RENTON STANDARDS NW z O F_ Z NW Ii SURVEYED: Z.NALL SCALE: VERTICAL 1988 HORZONTAL::NAD D1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY % CITY OF RENTON Planning/Building/Public Works Dept.(�Q ARCO/M U RRAY TOPGOLF RENTON 780 LOGAN AVENUE NORTH WA °Q RENTON, O57 DATE: 09.26.2022 LL O O DESIGNED: J.GREEN NAVIX 09.29.22 JET OOK: PAGE: PAGE. NAVIX 06.10.22 JET DRAWN' J.GREEN DRAWING NO: C-4• ■ NAVIX 05.17.22 JET CHECKED: J.TAFLIN BY DATE APPR APPROVED: WATER DETAILS SHEET: OR �82j J.TAFLIN 56 SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. M N Tm N ^^I 1� I— m%4 n 00 N-) Lri I N N CD N N Q (D cf) SHACT4LE RODS „ ... TYPE A 1LOCKING mom. TYPE B } + PUBLIC WORKS CONCRETE BLOCKING OR VERTICAL FITTINGS DEPARTMENT II +'EUPORARY 2" CALVANIZED PIPE AND 2" GATE VALVE .LI'I SHED GRADE ELEVATION INSTALL 2" PLUG ON TOP BLIND FLANGE AFTER REMOVAL OF POLYPIG 3 Fll MINL COVER (10-INCH DIAMETER AND UNDER) 4 FT MIN. COVER (12-INCH DIAMETER AND OVER) NEW WATER MAIN POLYPIG ~I � VERTICAL CROSS FOR POLYPICCING STATION. - SIZE 4F VERTICAL CROSS SHALL 13E THE SAME AS SIZE DF MAIN LINE VERTICAL CROSS (MJ X FL) Did€ BLIND FLANGE ON TOP OF CROSS WITH 2" TAP & 2" TEMPORARY BLOW --OFF ASSEMBLY (REMGVE BLOW -OFF ASSEMBLY AND INSTAL). 2' PLUG AFTER REMD'Mt OF CLEANING "POLY -PIG") ONE BLIND FLANG€ ON BOTTOM OF CROSS ON€ PLUG (MJ) DIN END OF CRO55 CONCRETE BLOCKING ALL DEBRIS AND POLYPIGS SHALL, BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION DF NEW WATER MAIN REGISTER SHALL BE TOUCH READ PIT Up a" RasT INDICATOF? VALVE PRECAST CONCRETE VAULT WITH 3 - Y7 31 ONE EACH SIDE (TR-PL) AND BE INTELLIGENT COMMUNICATION HINGED STEEL PLATE COVERS. DIMENSIONS ENCODER TYPE ICE METERGIENT MUST REAP W tMJXKW) PAINTM FLUE 4" ADAPTER, FL_x SCREWED 5',Syx 11'-2"x 7�-2" E41JeAi TO U3TLITY } 2-3j4" SHACKLE OCAS PER CITY VAULT OR EQUAL 4"x4 xfi" BULL HEAD TEE. FL- U. FT, OF RENTON SPECIFICATFONS TOUCH READ PIT LIT) SENSOR A' G4' RFNo ("u) "- 4" 9O' LIEND CMW) MOUNTED ON STCEL I'LAM ptpg FL x 1NSTALL IN TEST COVER THROUGH IN CO DER_ 4 DRILLED FIOLE IH COVER. FL 2'-D" L T3 LF 4" D.1 PORT A NIPPLE . TEE (M.I.:L) � BRASS NIPPLE WITH 12" THE BY-PASS AS$EMRLY SHALL BE w GATE VALVk (1T_xMU} 7�,0" A 2" RESILIENT i o � INCLUDED A�5 PART OF THE DETECTOR SEATED BRASS GATE DOUBLE CHECK VALVE A55EMBLY 18" FOR 10" ASSEMBLY e z J LADDER WITH VALVE AND 2" PLUG. 5/8"x3%4" EENSUS SRII (TR/PQ METER 17 1/2" FOR 9" ASSElA9LY a' FLxMJ ADAPTOR SUPPORT BARS :2 -4" 4" FLaMJ ADAPTOR WITH ICE REGISTER, 14 1/2' FOR 6" ASSEMBLY * PER Obi ti I - 2 4" a b" D.I. _ _ CIS PRIVATE TQ BALIXNG PIPING PIPIN4 e EPDXY NON -SHRINK 1T (Md I, FL) 11 GROW? • " GATE VALVE EFL W MS1 2'-1rr 4" TEE (M16-1_3 5•_ S•• WELDED STEEL COLLAR CITY PRIVATE TOUCH READ PIT UD SENSOR MOUNTED ON STEEL PLATE COVER THROUGH 2" DSA PIPING PIflNG vE4 ID I.ED HOLE IN COVER. LOCATE HOLE FN3" FROM EDGE OF PIT LID AND RIPS {� TEE RE0IJIRED VnTH 'SHACKLING TO TEE !2" ALL AROUND 2 - 6 _ (FL} CONCRETE r 1,• . _ _ - PRECAST CONCRETE VAUL7 OATH 2 3".3" HINCM STEEL BLQCKkNG - PLATE COVER, OUTSIDE DIMENSIONS a'-13'a7'•-D'• (EQUAL TO PEPE INC., 0R UTILIZY VAULT WITH ALL DETECTOR DOU@LE CHECK YALVE 57-71L-8, 2 SxV DIAMOND PLATE DOO)RSI SENSUS MODEL 52OR RADIO READ PIT SET SENSOR B" OR 6" FLx P.E_ ASSEMBLIES SHALL INCLUDE RESILIENT PLAN 8',�S" Oli 3- GATE VALVE {FL:FL] MOUNTED ON STEEL RLAT1= TVlU PIECE fin',,; 1-�.•I:.,',..t_,.� COVER THROUGH 2' OLA. EQUAL TO OLYMPIG FOUNDRY CO- i:IrE VATii COLLAR 1$` FROM P_E. SEATED SHUTOFF VALVES AND TE5T COCKS AND APPROVED NON -RISING STEM WITH HAND WHEE EODAL 1-0 MIJELLER CO_A-231M-6. ➢FULLED HOLE IN COVER STANDARD 8 TOP SECTION, WIT}l i0"- LONG CROSS -CONNECTION CONTROL ASSEMBLIES PER DEPARTMENT OF REGULAR BASE SECTION LENGTH TO FI -6` B'- 3'-S" LONG HEALTH LATEST APPROVED LIST B" DR A" (LZxPE) CEMENT LJNED 5"- 4'-D, LONG DUCTILE IRON PIPE CLASS 52 3'-6" LONG N+T11 COLLAR 2D" FROM P.E. DOUBLE CHECK VALVE ASSEMBLY INCLUDES TWO RESIDENT SEATED EDUAL TO THOSE SUPPLIED BY PACIFIC VALVE NUT EXTENSION 1F RE;U!Pr_- 4HS17F7FF VAI VFS �3•' WATER WORKS UQ. INC. (ow013"/PRGE 6o96) " 10', 8'. OR 6' J:LANGED GDUPLJNG ADAPTER EQUAL TO ROMAC. 12- AROUND- 1, Ii LI 6'.4" OR 3" D"D 1�ao M tFl) J E4ilAL T9 S£N51JS SRII COMPOUND WITH TOUCHREAR PITUD I,C.E. REOS7f.R k WITH 4 WHEEL HIGH RESOLUTION AD,NSTAEpF STEEL FEET) RE615TER. FOR 3' METER, REDUCE AT PE SUPPCIi1' METER MTH 4'X3' FL.FL .CONCENTRIC STANQHION BOLTED REDUCER. Tp FLOOR GENERAL NOTES: ALL iAETERS AND BACKFLOW PREVENTION DEVICE COMBINATIONS ARE NOT SHM OR ENCLUDEO IN THE STANDARC DETAIL DRAWINGS, IF YOUR PARTICULAR COMBINAIICN IS NOT SHOWN. AN APPROVED DRAWING WILL BE REQUIRED BY THE UTILITY ENGINEERING DEPT FOR ITS INSTALLATION, THE PRINOPAL REQUIREMENTS REGARDING VAULT SIZING ARE THE LENGTH OF FITTINGS OR THEIR CLEARANCE FROM THE VAULT WALLS, [WHtCii CLEARANCE SHALL SE A MINIMUM OF 12" FROM THE ENDS AND THE SIDE CLEARANCE SHOULD BE A$ TYPICALLY SHOYIIN ON THE VARtOU5 STANDARD DETAILS}. NOTE: DEADMAN BLDCK SHALL BE DESIGNED AND INSTALLED S❑ IT REARS AGAINST SUFFICIENT UNDISTURBED EARTH SO AS TO SUPPORT THE DESIGNED] THRUST- 6 • 4 OR 3 GATE VALVC (FLxMJ) EOWAL TO MUELLER CO A-23B0-20_ rO BUII'DING CITY PRIuvTE PIPHfG P14xp{C V6' Oft 4" PExPE CEMENT 1JNE0 OUDTILE IRON PkPE CLASS 52. LENGTH TO FIT. 5" QR 4' FLEXIBLE FLANOEU L'UUHLJ'RG AU.Ah'IL41, "UMAU DR APPIWV♦=D ECIUAL TOUCH READ PIT LID SENSOR MOUNTED NOTE: ON STEEL PLATE COVER THROUGH 2" DIAL. DRILLED HOLE IN COVER, I_ LOCATE VAULT IN PLANTING AREA. NOT IN PAVING. 2. 4" AND LARGER BENDS AND TEES TO BE CAST IRON CEMENT UNEi7, 18" FOR 10' ASSEMBLY 17 1/2 FOR B' ASSEMBLY IS 3 TEMPORARY SUPPORT SHALL BE PROVIDED UNDER 1/2' 1/2' FOR 6" ASSEMBLY 2ALVES AT THE TIME OF INSTALLATION TO CENTER THE PIPE IN VAULT OPEN NG. AFTER COMPLETE 5r6'x3/4' INVENSYS INSTALLATTON REMOVE THE TEMPORARY SUPPORT TR-PL METER WTH T•-2" AND INSTALL AD.iUSTABLE PIPE SUPPORT. ICE REGISTER IhSTAtL GALVANIZED LADDER FOR ACCESS. 6" ViN, DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM WITH AFTER FIELD INSTALLATION, MAIN DDCVA AND CATCH BASIN 04. MANHOLE BY-PASS DCVA VUST BE TESTED -SATISFACTORILY BY A DEPT. OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED TO CITY OF R£NTON WATER UTILITY ENGINEERING DEPT. PRIOR TO ACTIVATION OF NEW LINE COMPACTED FOUNDATION " INSTALL BRASS A* FLARE TEST COCKS Willi Y." GRAVEL FLARE CAPS. 4'x 2 1/2' FIRE DEPARTMEt•1T DOUBLE CONNECTION FOR STAND PIPE WITH BREAKABLE CAST IRON HOSE CAPS. ONE EACH SIDE ECIUAL TO GRINNEL FIG. 1662 WITH HOSE CAPS FIG, 1333_ - 6' SWING TYPE GRAVITY OPERATED CHECK VALVE. FL, EQUAL TO MUELLER CO. A-2600-6 WITH BALL DRIP VALVE AT BOTTOM INSTALL EPDXY NON -SHRINK CROUT (T)P.). 5" PIPE. FL x FL. 3.0" LONG [6'& 8' ASSEMBLY. 6' SFIOF RADIUS 90' BEND FL 1fl" A-,gFURIY 9{1' REDUCING BEND FL. ITO BUIL➢ING DEADMAN a BLOCK REQUIRED. 8".6' FL x MJ ADAPTOR 10' ASSEMBLY 10"00"xa'TEE FL. 8' A55EMBLY B'xB"x5" TEE, FL 6' A51AMBLY 0'4"4" TEE, FL. 10% B'• OR 6' GATE VALVE, FLx MJ, WITH INDICATOR POST. INDICATOR POST VALVE SAME SIZE A$ PQURLE CHECK VALVE (MUELLER CO. OP EQUAL). PAINTED RtD. 10`, 8", OR 6" 01tCTILE IRON CLASS 52 NIPPLE PIPE, CEMENT uNED, LENGTH TO FIT PI x 5" 90' BEND FL.� GALVANIZED tf�STER .ADDFP 1 AMWSTADLC STEEL PIPE SUPI'GRT, STANCHIONS BOLTED TO FLOOR. STD. PLAN - 330.3 4 STD. PLAN 300.8 „ sm. Pi" - 520.4 6" S" & 1 D" ❑ O U B L E DETECTOR CHECK STD . PLAN - 360.2 t PUBLIC WORKS POLY PIG STATION FOR CLEANING OF * + PUBLIC WORKS 3", 4 & 6' COMPOUND DOMESTIC sI PUBLIC WORKS ASSEMBLY WITH STANDPIPE OUTSIDE ,VARCH 2O10 I]EPARTMENT WATER MAINS -MARCEL 2010 f a. DEPAR'FMENT WATER METER ASSEMBLY MARCH 2010 _ DEPARTMENT MARCH 2010 INSTALLATION 3„MAx. Z o0 � C] 5"MIN. TO Cl TY METER STACKED METER SECTION\_6" MIN. FREE BOXES DRAININC CRAVI=- NOTES-. 1, ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA'sj MUST BE LISTED ON LATEST LIST OF 'BACKFLOW PREVENT10r.. ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE ❑F WASHINGTON [DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENT4N PLUMBING PERMI'T FOR THE INSPECTION OF THE IN5TALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAhNTAIN THE DCVA ANO ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST RE TESTED BY A STATE CERTIFIER E4CKFLOW ASSEMELY TESTER AFTLR ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S E}CPENSE_ A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING ❑EPT_, ATTN: WATER UTILITY CROSS —CONNECTION CONTROL SPECIALIST, FAX NO. 425-434-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER VETER_ T" Q Q 1 N LA Q Q Q C) 1 r lirA "'I"lX 1 a -ITS I CIVIL 11235 s.e. 6th street I suite 150 bellevue, wa 98004 t: 425.453.9501 1 f: 425-453-8208 www.navixeng.com ��,I WA 6ABET itally sign y nelle T flin Date: 2022.09.3 418726:3,9:41- zoo' ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON OUR Z VISUAL OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR PROVIDED RECORD INFORMATION. Q NAVIX CERTIFICATION Q W-412309 BY o V IN COMPLIANCE WITH CITY OF RENTON STANDARDS W �l Y PUBLIC WORKS 34" TO 2" DOUBLE CHECK VALVE SM. PLAN - 340.8 Z DEPARTMENT ASSEMBLY FOR IRRIGATION OR O RESIDENTIAL FIRE SPRINKLER MARC14 2010 Z NW w SURVEYED: SCALE: DATE: VERTICAL: NAV1988 Z.NALL HORIZONTAL: NAD D1983/1991 ARCO/M U RRAY 09.26.2022 J DESIGNED: % CITY OF FIELDBOOK: 2 RECORD DRAWINGS NAVIX 09.29.22 JET J.GREEN TOPGOLF RENTON ® 2 RECORD DRAWINGS NAVIX 06.10.22 JET DRAWN: PAGE: '� RENTON 780 LOGAN AVENUE NORTH PAGE• O ONE INCH DATUM (�DRAWING NO: Q 1 RECORD DRAWINGS NAVIX 05.17.22 JET CHECKED: AT FULL SCALE RENTON WA 98057 C-4.8 a G� J.TAFLIN IF NOT ONE INCH Planning/Building/Public Works Dept. NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY WATER DETAILS SHEET: OF: O J.TAFLIN 57 82