Loading...
HomeMy WebLinkAboutT-412303n Lnn SECTION 08, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. M N r r O H z O H z Lu w LL J O 0 IL O I— E cu O� 0 CV CV C=) CV a> cn c- o� J U N M 0 cn a M E aD cu U O J cu 0 M_ CD - CD 0 a) cn T J GENERAL NOTES "SITE" A. ELECTICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING PLANS FOR TEMPORARY POWER FOR OBTAINING PERMIT.PLANS SHALL INCLUDE RISER DIAGRAM,GROUNDING,FAULT CURRENT CALCULATION AND SITE PLAN SHOWING LOCATION OF ALL ELECTRICAL EQUIPMENT. B. PROVIDE 8' OF SEPARATION BETWEEN THE SIDES OF THE TARGETS AND ALL RACEWAYS. C. POLE BASES FOR SITE LIGHTING FIXTURES SHALL BE PROVIDED BY CONCRETE CONTRACTOR (LAYOUT INCLUDED). REFERENCE STRUCTURAL DRAWINGS FOR POLE BASE STRUCTURAL REQUIREMENTS. D. PROVIDE (1) 1" EMPTY PVC CONDUIT WITH PULL WIRE FROM PANEL LT TO EACH TARGET MANHOLE. E. PROVIDE MULE TAPE IN ALL DATA CONDUITS 1-1/2" AND GREATER. F. REFERENCE E9.01 DETAIL PLAN FOR TARGET POWER AND DATA REQUIREMENTS. G. REFERENCE LV2.1 FOR LV CONDUIT REQUIREMENTS. H. KEEP ALL ELECTRICAL BOXES 8" BELOW THE BOTTOM OF "C" CHANNEL IN EACH TARGET. I. ALL 277V CIRCUIT LENGTHS GREATER THAN 180 FT SHALL BE INCREASED TO #10 AWG AND TO #8 AWG WHEN GREATER THAN 290 FT. INCREASE CONDUIT SIZE FOR 40% FILL. ALL 120V CIRCUIT LENGTHS GREATER THAN 100 FT. SHALL BE INCREASED TO #10 AWG AND TO #8 AWG WHEN GREATER THAN 250FT INCREASE CONDUIT SIZE FOR 40% FILL. KEYED NOTES "POWER" EP-12 PROVIDE OZ GEDNEY CABLE SEALS FOR SERVICE ENTRANCE CONDUCTORS IN EACH SERVICE RACEWAY. EP-57 PROVIDE (2) 2-1/2" PVC FROM "MSB" TO TLED FOR HD SPECTACULAR POWER. PROVIDE CONCRETE PULLBOX EVERY 250'. USE 45 DEGREE BENDS FOR PVC CONDUIT. REFERENCE E5.0. EP-58 PROVIDE N3R DISCONNECT FOR PUMP CONTROLLER FBO/IBE FED FROM MSB, IF PUMP CONTROLLER IS NOT FURNISHED. PROVIDE 2-FUSIBLE N3R DICONNECTS 1 FOR EACH PUMP ON SUPPORT RACK. ALL CONTROLS & CONTROL WIRING DONE BY PUMP PROVIDER. EP-59 PROVIDE 2" PVC WITH MULE TAPE FROM JUNCTION BOX AT TRENCH TARGET TO SERVER ROOM. HD SPECTACULAR JOBS ONLY. EP-60 RECEPTACLES MOUNTED TO POLES 18" AFF TYPICAL OF (3). REFERENCE DRAWING E7.01/08 FOR MORE INFORMATION. CIRCUIT TO LT-26. EP-61 REFERENCE HD SPECTACULAR DRAWINGS FOR ADDITIONAL INFORMATION REGARDING LOCATION AND OUNTING FOR PANELS. EP-62 PROVIDE RED FLASHING OBSTRUCTION BEACON AT TOP OF POLE. ONE SYSTEM PER POLE INCLUDES ONE L-864 BEACON. LIGHT FIXTURE TO BE FURNISHED BY OWNER. COORDINATE INSTALLATION OF LIGHTS AND CIRCUITING PRIOR TO ERECTION OF POLE. EP-63 PROVIDE AND INSTALL 100A/3P N3R DISCONNECT FOR TRANSFORMER PRIMARY DISCONNECTING MEANS. VERIFY EXACT REQUIREMENTS AND LOCATION OF DISCONNECT PRIOR TO ROUGH IN. REFERENCE E5.00. EP-64 PROVIDE AND INSTALL 225A/3P N3R DISCONNECT FOR TRANSFORMER PRIMARY DISCONNECTING MEANS. VERIFY EXACT REQUIREMENTS AND LOCATION OF DISCONNECT PRIOR TO ROUGH IN. REFERENCE E5.00. EP-66 PROVIDE(2) 4" DATA CONDUITS FOR TELE/DATA SERVICE TO IT ROOM. REFER TO LOW VOLTAGE DRAWINGS FOR PLACEMENT DIMENSIONS IN IT ROOM. VERIFY EXACT REQUIREMENTS FOR MONUMENT SIGN WITH GENERAL CONTRACTOR PRIOR TO ROUGH IN. PROVIDE LOCAL CONTROL BY WAY OF PHOTOCELL FOR MONUMENT SIGN. COORDINATE WITH SIGN CONTRACTOR FOR EXACT LOCATION OF PHOTOCELL. EP-68 EXISTING CIRCUIT IS 240V, SINGLE-PHASE, 20A. EP-69 ELECTRICAL CONTRACTOR SHALL CONNECT PEDESTRIAN POLE LIGHTING TO CIRCUIT USED FOR ROADWAY LIGHTING. REF. DETAIL 1/E7.4 AND 2/E7.4 FOR INSTALLATION DETAILS. SURVEYED: SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DESIGNED: 0 B.PATE ODRAWN: o B.PATE ONE INCH DATUM `\ RECORD DRAWINGS FD 09/19/22 CHECKED: F. D E R A S IF AT FULL SCALE \ NOT ONE INCH N 0. REVISION BY DATE A P P R aPPRoveD: SCALE ACCORDINGLY \, CITY OF RENTON Planning/Building/Public Works Dept. FS; FSG 2525 WALNUT HILL LANE SUITE 100 DALLAS, TX 75229 PH: 214-357-5697 FAX: 214-357-5794 WWW.FSGI.COM 4tiC0 4. 09.19.2022 T-412303 IN COMPLIANCE WITH CITY OF RENTON STANDARDS ARCO/MURRAY- TOPGOLFRENTON 780 LOGAN AVENUE NORTH RENTON, WA 98057 SITE LIGHTING PLANS N O N O O O d7 r z O F_ z 11 IS, DATE: 04.17.2020 L= FIELDBOOK: J PAGE: O DRAWING NO: 0 SL3 a0 SHEET: 78 82 1111,.