Loading...
HomeMy WebLinkAbout1981_Transcon_Company_ForestTerrace_ElectricalHousingTo:SUBMITTAL #16 - Electrical Housing and Conduits DATE: 4/23/2021 Attention:Trenton Skoda PHONE:(425)892-4041 Project:Forest Terrace (Pulte Homes) Union Ave and 95th, Renton, WA We are enclosing: Submittal Application Supplier Service Cabinet - Renton Standard Plan 122.1 Electrical Housing Transcon Company Type1&Type2 Junction Boxes Electrical Housing/ Electrical Connections Transcon Company Schedule 40 & 80 PVC Conduit Electrical Wiring Transcon Company Autobahn Roadway LED - Renton Standard Plan 115 Roadway Lighting Transcon Company (A)For approval or corrections - Return (B)For review and comment (C)Approved as corrected - Return (D)Approved - Work may proceed (E)Revise and resubmit - Work may proceed (F)Revise and resubmit - Work MAY NOT proceed Barghausen Consulting Engineers, Inc. 18215 72nd Ave S Kent, WA 98032 1 A ITEM #DESCRIPTION ACTION REQD. Product Service Cabinet per COR STD#122.1. 120/240 V, Single Phase, 3 Wire. Spec Ref: 9-29.24 Galvanized Steel 9-29.2(1)A 4 2 A 3 ARigid Non-Metallic Conduit 70-250W HPS Roadway Luminary A ACTION REQUIRED HOS BROS. CONSTRUCTION PO BOX 1788 WOODINVILLE, WA 98072 425-481-5569-PHONE 425-481-6634-FAX Transcon Company LLC Letter of Transmittal 5820 Corson Ave S. Suite A Seattle, WA 98108 Date:Job No: Attention: To:RE: We are sending you the following items via; x Email Hand Delivered Shop Drawings X Submittals Plans Specifications Copy of Letter Change Order These are transmitted as checked below: x For Approval Approved As Submitted For Your Use Approved As Noted As Requested Returned For Correction For Review and Comment Remarks: Signed: 4/22/2021 2021-003 Spencer Curtwright Hos Bros. Construction Forest Terrace Subdivision 7733 W.Bostian Road Woodinville, WA 98072 Copies Date No.Description 1 4/22/2021 1 Service Cabinet - Renton Standard Plan 122.1 Jason Collecchi Bid Item No. PE Appr'l Code File No. 2 Contractor Region Operations Engineer State Materials Lab Other Dot Form 350-071 EF Revised 3/07 4/22/2021 Specification Reference Name and Location of Fabrication Manufacturer or Pit Number Contract FA Number SR Material or Manufacturer's Product/Type Skyline, Seattle,WA Hos Bros. Construction Contractor Subcontractor Transcon Service Cabinet per COR STD#122.1 9-29.24 10. Approval Withheld: 11. Date Ram # 9. Approval Withheld: Submit samples for preliminary evaluation. Washington State Request for Approval of Material For assistance in competing, see instructions and Example County King County Section Date 8. Source Approved: Approval Action Codes for use by Project Engineer and OSC Materials Laboratory 1. Conditionally Approved: Acceptance based upon 'Satisfactory' Test Report for samples of material to be incorporated in the project. 2. Conditionally Approved: Submit Mfg. Cert. of Compliance for 'Approval prior to use of material. Department of Transportation OSC Appr'l Code Region Materials Fabrication Inspection General File Project Engineer Date State Materials Engineer Signing Inspection Remarks: Project Engineer Distribution State Materials Engineer Distribution 3. Conditionally Approved: Submit Catalog Cuts for 'Approval' prior to use of materials to use of material. 4. Conditionally Approved: Submit Shop Drawings for 'Approval' prior to fabrication of material. 5. Conditionally Approved: Only 'Approved for Shipment' or 'WSDOT Inspected' material shall be used. 6. Conditionally Approved: Submit Materials Certificate of Origin to Project Engineer. 7. Approval Pending: Request Transmitted to State Materials Laboratory for Approval Action. FOREST TERRACE TACOMA for TRANSCON SKYLINE ELECTRIC & MFG. CO. SCALE DATE / DRAWN BY DRAWING NO. N.T.S. 3-16-21 / C.S.T. 67318 1 2 3 4 5 6 ELEVATION SECTION “SERVICE 1” CITY OF RENTON SKYLINE SERIES# 64380 1 REQUIRED SEE COMPONENT SCHEDULE AND CABINET SPECIFICATIONS THE METER DOOR IS REMOVABLE AND COMES STANDARD HINGED ON THE LEFT. HINGING ON THE RIGHT IS AVAILABLE AS A NO-CHARGE OPTION WIRING SCHEMATIC METER BASE MAIN CONTROL LTG. GROUND FAULT RECEPT. PHOTO CELL TEST SWITCH 120/240V, SINGLE PHASE, 3 WIRE FOOTPRINT DEADFRONT SERVICE WIREWAY CITY OF RENTON SERVICE CABINET PER STANDARD PLANS 122.1, 122.2 SKYLINE SERIES# 64380 “SERVICE 1” COMPONENT SCHEDULE 1 METERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ 5TH JAW AT 9:00 POSITION 2 PANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 12 CKT, 10K AIC MAIN BREAKER: 125 AMP FRAME, 100 AMP TRIP, 2 POLE, EATON BAB2100 (BACK-FED) BOLT-ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B 1 - 20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE 1 - 15/1 CONTROL 3 - 20/1 SPARE 3 CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 8910DPA34V02 – 1 REQUIRED 4 PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW 5 PHOTO-CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) 6 GROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8” 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2” ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE), STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, “BEST” LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED WIRE GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER-TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 – REQUIRED UL LISTED PER STANDARD #508A “SUITABLE FOR USE AS SERVICE ENTRANCE” FOREST TERRACE CITY OF RENTON TACOMA P.O.# 264586-00 TRANSCON 3-16-21 C.S.T. S.O.# 67318 SKYLINE ELECTRIC & MFG. COMPANY I N C O R P O R A T E D Switchboards Panelboards Steel Cabinets UL Registered Metal Punching . . Forming . . Welding Industrial Control Panels 3619 7TH AVENUE SOUTH SEATTLE, WASHINGTON 98134 TELEPHONE (206) 682-4422 FAX (206) 682-0927 Transcon Company LLC Letter of Transmittal 5820 Corson Ave S. Suite A Seattle, WA 98108 Date:Job No: Attention: To:RE: We are sending you the following items via; x Email Hand Delivered Shop Drawings X Submittals Plans Specifications Copy of Letter Change Order These are transmitted as checked below: x For Approval Approved As Submitted For Your Use Approved As Noted As Requested Returned For Correction For Review and Comment Remarks: Signed: 4/22/2021 2021-003 Spencer Curtwright Hos Bros. Construction Forest Terrace Subdivision 7733 W.Bostian Road Woodinville, WA 98072 Copies Date No.Description 1 4/22/2021 2 Type1&Type2 Junction Boxes Jason Collecchi Bid Item No. PE Appr'l Code File No. 2 Contractor Region Operations Engineer State Materials Lab Other Dot Form 350-071 EF Revised 3/07 4/22/2021 Specification Reference Name and Location of Fabrication Manufacturer or Pit Number Contract FA Number SR Material or Manufacturer's Product/Type H2 Precast, Wenatchee,WA Hos Bros. Construction Contractor Subcontractor Transcon Type1&Type2 Junction Boxes 9-29.2(1)A 10. Approval Withheld: 11. Date Ram # 9. Approval Withheld: Submit samples for preliminary evaluation. Washington State Request for Approval of Material For assistance in competing, see instructions and Example County King County Section Date 8. Source Approved: Approval Action Codes for use by Project Engineer and OSC Materials Laboratory 1. Conditionally Approved: Acceptance based upon 'Satisfactory' Test Report for samples of material to be incorporated in the project. 2. Conditionally Approved: Submit Mfg. Cert. of Compliance for 'Approval prior to use of material. Department of Transportation OSC Appr'l Code Region Materials Fabrication Inspection General File Project Engineer Date State Materials Engineer Signing Inspection Remarks: Project Engineer Distribution State Materials Engineer Distribution 3. Conditionally Approved: Submit Catalog Cuts for 'Approval' prior to use of materials to use of material. 4. Conditionally Approved: Submit Shop Drawings for 'Approval' prior to fabrication of material. 5. Conditionally Approved: Only 'Approved for Shipment' or 'WSDOT Inspected' material shall be used. 6. Conditionally Approved: Submit Materials Certificate of Origin to Project Engineer. 7. Approval Pending: Request Transmitted to State Materials Laboratory for Approval Action. Hð Pre-Cast Inc. 3835 N Clemons East Wenatchee, WA 98802 Hð Pre-Cast Inc. 3835 N Clemons East Wenatchee, WA 98802 Transcon Company LLC Letter of Transmittal 5820 Corson Ave S. Suite A Seattle, WA 98108 Date:Job No: Attention: To:RE: We are sending you the following items via; x Email Hand Delivered Shop Drawings X Submittals Plans Specifications Copy of Letter Change Order These are transmitted as checked below: x For Approval Approved As Submitted For Your Use Approved As Noted As Requested Returned For Correction For Review and Comment Remarks: Signed: 4/22/2021 2021-003 Spencer Curtwright Hos Bros. Construction Forest Terrace Subdivision 7733 W.Bostian Road Woodinville, WA 98072 Copies Date No.Description 1 4/22/2021 3 Schedule 40&80 PVC Conduit Jason Collecchi Bid Item No. PE Appr'l Code File No. 3 3 Contractor Region Operations Engineer State Materials Lab Other Dot Form 350-071 EF Revised 3/07 4/22/2021 Specification Reference Name and Location of Fabrication Manufacturer or Pit Number Contract FA Number SR Material or Manufacturer's Product/Type Ridgeline- Eugene, Oregon Prime- Cleveland,OH Hos Bros. Construction Contractor Subcontractor Transcon Schedule 40&80 PVC Conduit Schedule 40&80 PVC Conduit 9-29.1(4)A 9-29.1(4)A 10. Approval Withheld: 11. Date Ram # 9. Approval Withheld: Submit samples for preliminary evaluation. Washington State Request for Approval of Material For assistance in competing, see instructions and Example County King County Section Date 8. Source Approved: Approval Action Codes for use by Project Engineer and OSC Materials Laboratory 1. Conditionally Approved: Acceptance based upon 'Satisfactory' Test Report for samples of material to be incorporated in the project. 2. Conditionally Approved: Submit Mfg. Cert. of Compliance for 'Approval prior to use of material. Department of Transportation OSC Appr'l Code Region Materials Fabrication Inspection General File Project Engineer Date State Materials Engineer Signing Inspection Remarks: Project Engineer Distribution State Materials Engineer Distribution 3. Conditionally Approved: Submit Catalog Cuts for 'Approval' prior to use of materials to use of material. 4. Conditionally Approved: Submit Shop Drawings for 'Approval' prior to fabrication of material. 5. Conditionally Approved: Only 'Approved for Shipment' or 'WSDOT Inspected' material shall be used. 6. Conditionally Approved: Submit Materials Certificate of Origin to Project Engineer. 7. Approval Pending: Request Transmitted to State Materials Laboratory for Approval Action. 2220 Nugget Way - Eugene, OR 97403 - Phone (877) 811-7473 - Fax (541) 746-6111 E-112 (03/13) ® PVC Rigid Electrical Conduit Schedule 40 Conduit Conduit is manufactured to be in conformance with NEMA TC 2 and UL 651. Designed and produced for use in both above ground and below ground applications. Product manufactured with one integral solvent-weld bell standard per length. Part Number Dimensions (inches) Minimum Wall Approximate Weight Standard Crate Quantity 10’ 20’ Size OD (Avg) ID (Approx) (inches) per 100’ 10’ 20’ 4005010 4005020 ½” 0.840 0.60 0.109 16 6,000 12,000 4007510 4007520 ¾” 1.050 0.80 0.113 21 4,400 8,800 4010010 4010020 1” 1.315 1.03 0.133 33 3,600 7,200 4012510 4012520 1 ¼” 1.660 1.36 0.140 46 3,300 6,600 4015010 4015020 1 ½” 1.900 1.59 0.145 56 2,250 4,500 4020010 4020020 2” 2.375 2.04 0.154 73 1,400 2,800 4025010 4025020 2 ½” 2.875 2.44 0.203 119 930 1,860 4030010 4030020 3” 3.500 3.03 0.216 165 880 1,760 4035010 4035020 3 ½” 4.000 3.51 0.226 199 630 1,260 4040010 4040020 4” 4.500 3.99 0.237 235 570 1,140 4050010 4050020 5” 5.563 5.01 0.258 319 380 760 4060010 4060020 6” 6.625 6.02 0.280 414 260 520 Tested and Certified by NSF International to UL 651 2220 Nugget Way - Eugene, OR 97403 - Phone (877) 811-7473 - Fax (541) 746-6111 E-113 (03/13) ® PVC Rigid Electrical Conduit Schedule 80 Conduit Conduit is manufactured to be in conformance with NEMA TC 2 and UL 651. Designed and produced for use in both above ground and below ground applications. Product manufactured with one integral solvent-weld bell standard per length. Part Number Dimensions (inches) Minimum Wall Approximate Weight Standard Crate Quantity 10’ 20’ Size OD (Avg) ID (Approx) (inches) per 100’ 10’ 20’ 8005010 8005020 ½” 0.840 0.52 0.147 20 6,000 12,000 8007510 8007520 ¾” 1.050 0.72 0.154 28 4,400 8,800 8010010 8010020 1” 1.315 0.93 0.179 41 3,600 7,200 8012510 8012520 1 ¼” 1.660 1.25 0.191 58 3,300 6,600 8015010 8015020 1 ½” 1.900 1.47 0.200 72 2,250 4,500 8020010 8020020 2” 2.375 1.90 0.218 101 1,400 2,800 8025010 8025010 2 ½” 2.875 2.28 0.276 154 930 1,860 8030010 8030020 3” 3.500 2.85 0.300 200 880 1,760 8040010 8040020 4” 4.500 3.77 0.337 306 570 1,140 8050010 8050020 5” 5.563 4.76 0.375 439 380 760 8060010 8060020 6” 6.625 5.70 0.432 603 260 520 Tested and Certified by NSF International to UL 651 www.primeconduit.com Prime Conduit™Schedule 40 & 80 Conduit & Elbows Schedule 40 Conduit Schedule 80 Conduit Schedule 40 Conduit Schedule 40 Elbows Schedule 80 Elbows Schedule 40 Elbows Properties Expansion & Contraction Corrosion Resistance Specification Schedule 40 Utility Conduit &Elbows www.primeconduit.com2 Rigid Nonmetallic Conduit – Schedule 40 and Schedule 80 Prime Conduit™manufactures the most complete line of nonmetallic conduits in the electrical industry. Prime Conduit Schedule 40 and Schedule 80 conduits are designed for use aboveground and underground as described in the National Electrical Code. Specify only Prime Conduit conduits to insure raceway system quality. Features Ease of Installation Nonmetallic conduits are 1/4 to 1/5 the weight of metallic systems, can be installed in less than half the time, and are easily fabricated on the job. Safety Nonmetallic conduits are nonconductive, assuring a safe system. Impact Resistant Prime Conduit Schedule 40 and Schedule 80 nonmetallic conduits are resistant to sunlight and are listed for exposed or outdoor usage. Corrosion Resistant Prime Conduit conduits are nonmetallic and will not rust or corrode. Prime Conduit nonmetallic Schedule 40 and Schedule 80 conduits and elbows are manufactured to NEMA TC-2, Federal specification WC1O94A and UL 651 specifications. The conduit carries respective ETL Listings and ETL labels. Part No.Std. Crate Qty. Wt. Per Dimensions 10'20'Trade Size 10' 20' 100' O.D. I.D. Wall 49005-010 1/2"6000'17 .840 .622 .109 49007-010 49007-020 3/4"4400' 8800' 23 1.050 .824 .113 49008-010 49008-020 1" 3600' 7200' 34 1.315 1.049 .133 49009-010 49009-020 1 1/4"3300' 6600' 46 1.660 1.380 .140 49010-010 49010-020 1 1/2"2250' 4500' 55 1.900 1.610 .145 49011-010 49011-020 2" 1400' 2800' 73 2.375 2.067 .154 49012-010 49012-020 2 1/2"930' 1860' 124 2.875 2.469 .203 49013-010 49013-020 3" 880' 1760' 163 3.500 3.068 .216 49014-010 49014-020 31/2"630' 1260' 196 4.000 3.548 .226 49015-010 49015-020 4" 570' 1140' 232 4.500 4.026 .237 49016-010 49016-020 5" 380' 760' 315 5.563 5.047 .258 49017-010 49017-020 6" 260' 520' 409 6.625 6.065 .280 With Integral Bell* Prime Conduit Schedule 40 PVC Rigid Nonmetallic Conduit (RNC). (Heavy Wall EPC) Listed for underground applications encased in concrete or direct burial.Also for use in exposed or concealed applications aboveground. •Sunlight resistant •Rated for use with 90˚C conductors •Superior weathering characteristics • Made in USA Schedule 40 Heavy Wall Rigid nonmetallic conduit is normally supplied in standard 10' lengths, with one belled end per length. For specific requirements, it may be produced in lengths shorter or longer than 10', with or without belled ends. ETL Listed to UL 651 in compliance to the NEC Use RNC Fittings with Schedule 40 and Schedule 80 Conduit. Notes:1.Special conduit sizes will be quoted on request. 2. DON’T FORGET TO ORDER CEMENT. 3. Prime conduit reserves the right to ship to the nearest unitized quantity. RUS Accepted Prime Conduit™Rigid Nonmetallic Conduit (RNC) www.primeconduit.com 3 Rigid Nonmetallic Conduit – Support in Aboveground Installations Part No.Std. Crate Qty. Wt. Per Dimensions 10' 20'Trade Size 10' 20' 100' O.D. I.D. Wall 49405-010 49405-020 1/2"6000' 12000' 21 .840 .546 .147 49407-010 49407-020 3/4"4400' 8000' 30 1.050 .742 .154 49408-010 49408-020 1" 3600' 7200' 44 1.315 .957 .179 49409-010 49409-020 1 1/4"3300' 6600' 60 1.660 1.278 .191 49410-010 49410-020 1 1/2"2250' 3600' 72 1.900 1.500 .200 49411-010 49411-020 2" 1400' 2800' 101 2.375 1.939 .218 49412-010 49412-020 2 1/2"930' 1880 154 2.875 2.323 .276 49413-010 49413-020 3" 880' 1760' 210 3.500 2.900 .300 49415-010 49415-020 4" 570' 1140' 308 4.500 3.826 .337 49416-010 – 5" 380' – 428 5.563 4.813 .375 49417-010 49417-020 6" 260' 520' 588 6.625 5.761 .432 With Integral Bell* Use RNC Fittings with Schedule 40 and Schedule 80 Conduit. Notes:1. Special conduit sizes will be quoted on request. 2. DON’T FORGET TO ORDER CEMENT. 3.Prime Conduit reserves the right to ship to the nearest unitized quantity. Prime Conduit Schedule 80 PVC Rigid Nonmetallic Conduit (RNC) (Extra Heavy Wall EPC-80) Listed for use in aboveground and belowground applications including areas subject to physical damage. •Sunlight resistant •Rated for use with 90˚C conductors •Superior weathering characteristics •Identified for use in areas subject to physical damage in accordance to 352.12(C) Schedule 80 Extra Heavy Wall Rigid nonmetallic conduit is normally supplied in standard 10' lengths, with one belled end per length. For specific requirements, it may be produced in lengths shorter or longer than 10', with or without belled ends. Support of Prime Conduit Rigid Nonmetallic Conduit in Aboveground Installations Table 352.30(B) NEC shows the support requirements for Schedule 40 and Schedule 80 rigid PVC nonmetallic conduit. Plastic conduit should always be installed away from steam lines, etc. Support straps should allow for lineal movement caused by expansion and contraction. Maximum ambient temperature is 122°F (50°C). Table 352.30(B), NEC Trade Maximum Spacing Between Size Supports (feet) 1/2 - 1 3 11/4 - 2 5 21/2 - 3 6 31/2 -57 68 Acceptable Dimensions in Inches of Integral Bell per UL 651 ABC Trade At Entrance (in.) At Bottom (in.) Nominal Bell Size Maximum Minimum Maximum Minimum Depth (in.) 1/2 0.860 0.844 0.844 0.828 1.375 3/4 1.074 1.054 1.056 1.036 1.500 1 1.340 1.320 1.320 1.300 1.750 11/4 1.689 1.665 1.667 1.643 1.875 11/2 1.930 1.906 1.906 1.882 2.750 2 2.405 2.381 2.381 2.357 3.250 21/2 2.905 2.875 2.883 2.853 3.250 3 3.530 3.500 3.507 3.477 3.875 31/2 4.065 3.965 4.007 3.977 3.875 4 4.565 4.465 4.506 4.476 4.625 5 5.643 5.543 5.583 5.523 5.625 6 6.708 6.608 6.644 6.584 6.375 A B C ETL Listed to UL 651 in compliance to the NEC RUS Accepted 2220 Nugget Way - Eugene, OR 97403 - Phone (877) 811-7473 E-223 (06/16) Certified to UL 651 by ETL Intertek Conforms to NEMA TC-3 PVC Electrical Conduit Fittings & Accessories Standard Radius Elbows Schedule 40 45° Elbow 90° Elbow Part Number Part Number Dimensions (inches) Size Belled End Plain End Size Belled End Plain End A B (Min) C (Min) ½” F4005045 F4005045P ½” F4005090 F4005090P 0.840 4.000 1.500 ¾” F4007545 F4007545P ¾” F4007590 F4007590P 1.050 4.500 1.500 1” F4010045 F4010045P 1” F4010090 F4010090P 1.315 5.750 1.875 1 ¼” F4012545 F4012545P 1 ¼” F4012590 F4012590P 1.660 7.250 2.000 1 ½” F4015045 F4015045P 1 ½” F4015090 F4015090P 1.900 8.250 2.000 2” F4020045 F4020045P 2” F4020090 F4020090P 2.375 9.500 2.000 2 ½” F4025045 F4025045P 2 ½” F4025090 F4025090P 2.875 10.50 3.000 3” F4030045 F4030045P 3” F4030090 F4030090P 3.500 13.00 3.125 3 ½” F4035045 F4035045P 3 ½” F4035090 F4035090P 4.000 15.00 3.250 4” F4040045 F4040045P 4” F4040090 F4040090P 4.500 16.00 3.375 5” F4050045 F4050045P 5” F4050090 F4050090P 5.563 24.00 3.625 6” F4060045 F4060045P 6” F4060090 F4060090P 6.625 30.00 3.750 90° 45° B B b BB b Transcon Company LLC Letter of Transmittal 5820 Corson Ave S. Suite A Seattle, WA 98108 Date:Job No: Attention: To:RE: We are sending you the following items via; x Email Hand Delivered Shop Drawings X Submittals Plans Specifications Copy of Letter Change Order These are transmitted as checked below: x For Approval Approved As Submitted For Your Use Approved As Noted As Requested Returned For Correction For Review and Comment Remarks: Signed: Jason Collecchi 1 4/23/2021 4 Autobahn Roadway LED - Renton Standard Plan 115 7733 W.Bostian Road Woodinville, WA 98072 Copies Date No.Description 4/23/2021 2021-003 Spencer Curtwright Hos Bros. Construction Forest Terrace Subdivision Bid Item No. PE Appr'l Code File No. 2 Contractor Region Operations Engineer State Materials Lab Other Dot Form 350-071 EF Revised 3/07 4/23/2021 Specification Reference Name and Location of Fabrication Manufacturer or Pit Number Contract FA Number SR Material or Manufacturer's Product/Type AEL-Granville,Ohio HOS Bros Construction Contractor Subcontractor Transcon ATBO Roadway LED COR STD 115 10. Approval Withheld: 11. Date Ram # 9. Approval Withheld: Submit samples for preliminary evaluation. Washington State Request for Approval of Material For assistance in competing, see instructions and Example County King Section Date 8. Source Approved: Approval Action Codes for use by Project Engineer and OSC Materials Laboratory 1. Conditionally Approved: Acceptance based upon 'Satisfactory' Test Report for samples of material to be incorporated in the project. 2. Conditionally Approved: Submit Mfg. Cert. of Compliance for 'Approval prior to use of material. Department of Transportation OSC Appr'l Code Region Materials Fabrication Inspection General File Project Engineer Date State Materials Engineer Signing Inspection Remarks: Project Engineer Distribution State Materials Engineer Distribution 3. Conditionally Approved: Submit Catalog Cuts for 'Approval' prior to use of materials to use of material. 4. Conditionally Approved: Submit Shop Drawings for 'Approval' prior to fabrication of material. 5. Conditionally Approved: Only 'Approved for Shipment' or 'WSDOT Inspected' material shall be used. 6. Conditionally Approved: Submit Materials Certificate of Origin to Project Engineer. 7. Approval Pending: Request Transmitted to State Materials Laboratory for Approval Action. PRODUCT OVERVIEW Applications: Roadways Off ramps Residential streets Parking lots Autobahn Series ATB0 Roadway Lighting Features: OPTICAL Same Light: Performance is comparable to 70-250W HPS roadway luminaires. White Light: Correlated color temperature - 4000K, 70 CRI minimum, 3000K, 70 CRI minimum or optional 5000K, 70 CRI minimum. Unique IP66 rated LED light engines provided 0% uplight and restrict backlight to within sidewalk depth, providing optimal application coverage and optimal pole spacing. Available in Type II, III, IV, and V roadway distributions. ELECTRICAL Expected Life: LED light engines are rated >100,000 hours at 25°C, L70. Electronic driver has an expected life of 100,000 hours at a 25°C ambient. Lower Energy: Saves an expected of 40-60% over comparable HID luminaires. Robust Surge Protection: Three different surge protection options provide a minimum of ANSI C136.2 10kV/5kA protection. 20kV/10kA protection is also available. MECHANICAL Includes standard AEL lineman-friendly features such as tool-less entry, 3 station terminal block and quick disconnects. Bubble level located inside the electrical compartment for easily leveling at installation. Rugged die-cast aluminum housing and door are polyester powder-coated for durability and corrosion resistance. Rigorous five-stage pre-treating and painting process yields a finish that achieves a scribe creepage rating of 7 (per ASTM D1654) after over 5000 hours exposure to salt fog chamber (operated per ASTM B117). Mast arm mount is adjustable for arms from 1-1/4” to 2” (1-5/8” to 2-3/8” O.D.) diameter. Provides a 3G vibration rating per ANSI C136.31 Wildlife shield is cast into the housing (not a separate piece). CONTROLS NEMA 3 pin photocontrol receptacle is standard, with the Acuity designed ANSI standard 7 pin receptacle optionally available. Premium solid state locking style photocontrol - PCSS (10 year rated life) Extreme long life solid state locking style photocontrol - PCLL (20 year rated life). Multi-level dimming available to provide scheduled dimming as specified by the customer. Optional onboard Adjustable Output module allows the light output and input wattage to be modified to meet site specific requirements, and also can allow a single fixture to be flexibly applied in many different applications. Note: Specifications subject to change without notice. Actual performance may differ as a result of end-user environment and application. Effective Projected Area (EPA): The EPA for the ATB0 is 0.76 sq. ft.Approx. Wt. = 14 lbs. DIMENSIONS © 2014-2019 Acuity Brands Lighting, Inc. ATB0 02/21/19 STANDARDS DesignLights Consortium® (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified. Color temperatures of ≤ 3000K must be specified for International Dark- Sky Association certification. Rated for -40°C to 40°C ambient CSA Certified to U.S. and Canadian standards Complies with ANSI: C136.2, C136.10, C136.14, C136.31, C136.15, C136.37 Warranty Five-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/resources/terms-and-conditions Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. Please contact your sales representative for the latest product information. AEL Headquarters, 3825 Columbus Road, Granville, OH 43023www.americanelectriclighting.com© 2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. ATB0 02/21/19 Autobahn Series ATB0 Roadway Lighting ORDERING INFORMATION Example: ATB0 30LEDE10 MVOLT R2 ATB0 Autobahn LED Roadway MVOLT Multi-volt, 120-277V 347 347V 480 480V 10BLEDE70 10B Chips, 700mA Driver 10BLEDE10 10B Chips, 1050mA Driver 10BLEDE15 10B Chips, 1500mA Driver 20BLEDE53 20B Chips, 525mA Driver 20BLEDE70 20B Chips, 700mA Driver 20BLEDE10 20B Chips, 1050mA Driver 20BLEDE13 20B Chips, 1300mA Driver 20BLEDE15 20B Chips, 1500mA Driver 30BLEDE70 30B Chips, 700mA Driver 30BLEDE85 30B Chips, 850mA Driver 30BLEDE10 30B Chips, 1050mA Driver 30BLEDE13 30B Chips, 1300mA Driver 30BLEDE15 30B Chips, 1500mA Driver Color Temperature (CCT) (Blank) 4000K CCT, 70 CRI Min. 3K 3000K CCT, 70 CRI Min. 5K 5000K CCT, 70 CRI Min. Paint (Blank) Gray (Standard) BK Black BZ Bronze DDB Dark Bronze GI Graphite WH White Surge Protection (Blank) Standard 10kV/5kA SPD 20 20kV/10KA SPD MP1 MOV Pack IL1 SPD with Indicator Light Terminal Block (Blank) Terminal Block (Standard) T2 Wired to L1 & L2 Positions Misc. BL External Bubble Level HS House-Side Shield NL Nema Label XL Not CSA Certified UMR-XX 8” Horizontal Arm for Round Pole, Painted to match Fixture Options UMS-XX 8” Horizontal Arm for Square Pole, Painted to match Fixture UMR-GALV 8” Horizontal Arm for Round Pole, Galvanized UMS-GALV 8” Horizontal Arm for Square Pole, GalvanizedControls (Blank) 3 Pin NEMA Photocontrol Receptacle (Standard) P72 7 Pin Photocontrol Receptacle (Dimmable Driver Included) NR No Photocontrol Receptacle AO3 Field Adjustable Output DM 0V-10V Dimmable Driver (Controls by others) ML4,5 Multi-Level Dimming PCSS1 Solid State Lighting Photocontrol (120-277V) PCLL Solid State Long Life Photocontrol SH Shorting Cap Packaging (Blank) Single Unit (Standard) JP Job Pack (42/Pallet) R2 Roadway Type II R3 Roadway Type III R4 Roadway Type IV R5 Roadway Type V OpticsVoltagePerformance Packages Series Notes 1 Not available in 347 or 480V. 2 Not available with DM, ML or NR. 3 Not available with DM or ML options. Not available with 10BLED packages. 4 Not available with AO, DM or P7 options. 5 Dimming Schedule and light level information required from the customer in order to configure product. Contact Infrastructure Technical Support to proceed. Accessories (field installed): ATB0 LTS20 Light Trespass Shield for ATB0 LEM 20 ATB0 LTS30 Light Trespass Shield for ATB0 LEM 30 PERFORMANCE PACKAGE Autobahn Series ATB0 Roadway Lighting Note: Individual fixture performance may vary. ATB0 LLD Multiplier 15°C 20°C 25°C 30°C 35°C 40°C 1.02 1.01 1 0.98 0.97 0.95 To calculate the LLD for a temperature other than 25°C, multiply the LLD @ 25°C (shown in the performance package table) by the LLD multiplier for the selected temperature. Performance Package Drive Current (mA) Input Watts Optic 3K (3000K CCT, 70 CRI Min.)4K/5K (4000K/5000K CCT, 70 CRI Min.)LLD @ 25ºC Lumens LPW B U G Lumens LPW B U G 25k Hours 75k Hours 100k Hours 10B 700 25 R2 2,670 107 1 0 1 2,994 120 1 0 1 0.98 0.97 0.96 1050 37 4,006 108 1 0 2 4,293 116 1 0 2 0.97 0.95 0.92 1500 54 5,364 99 1 0 2 5,688 105 1 0 2 0.93 0.90 0.88 700 25 R3 2,702 108 1 0 1 3,009 120 1 0 1 0.98 0.97 0.96 1050 37 4,069 110 1 0 1 4,313 117 1 0 1 0.97 0.95 0.92 1500 54 5,409 100 1 0 1 5,742 106 1 0 1 0.93 0.90 0.88 700 25 R4 2,686 107 1 0 1 2,992 120 1 0 1 0.98 0.97 0.96 1050 37 3,934 106 1 0 1 4,232 114 1 0 1 0.97 0.95 0.92 1500 54 5,383 100 1 0 2 5,653 105 1 0 2 0.93 0.90 0.88 700 25 R5 2,806 112 2 0 1 3,065 123 2 0 1 0.98 0.97 0.96 1050 37 4,125 111 3 0 1 4,422 120 3 0 1 0.97 0.95 0.92 1500 54 5,551 103 3 0 1 5,844 108 3 0 1 0.93 0.90 0.88 20B 525 36 R2 4,328 120 1 0 2 4,638 129 1 0 2 0.98 0.97 0.96 700 48 5,652 118 1 0 2 5,956 124 1 0 2 0.98 0.96 0.95 1050 71 7,948 112 2 0 2 8,506 120 2 0 2 0.97 0.95 0.92 1300 87 9,157 105 2 0 3 9,922 114 2 0 3 0.93 0.90 0.88 1500 99 10,288 104 2 0 3 11,038 111 2 0 3 0.93 0.90 0.88 525 36 R3 4,436 123 1 0 1 4,704 131 1 0 1 0.98 0.97 0.96 700 48 5,705 119 1 0 1 6,114 127 1 0 2 0.98 0.96 0.95 1050 71 8,080 114 2 0 2 8,606 121 2 0 2 0.97 0.95 0.92 1300 87 9,442 109 2 0 2 10,065 116 2 0 2 0.93 0.90 0.88 1500 99 10,503 106 2 0 2 11,181 113 2 0 2 0.93 0.90 0.88 525 36 R4 4,459 124 1 0 2 4,676 130 1 0 2 0.98 0.97 0.96 700 48 5,766 120 1 0 2 6,022 125 1 0 2 0.98 0.96 0.95 1050 71 8,101 114 2 0 2 8,569 121 2 0 2 0.97 0.95 0.92 1300 87 9,321 107 2 0 2 10,053 116 2 0 2 0.93 0.90 0.88 1500 99 10,426 105 2 0 2 11,160 113 2 0 3 0.93 0.90 0.88 525 36 R5 4,540 126 3 0 1 4,869 135 3 0 1 0.98 0.97 0.96 700 48 5,832 122 3 0 1 6,287 131 3 0 1 0.98 0.96 0.95 1050 71 8,241 116 3 0 2 8,880 125 3 0 2 0.97 0.95 0.92 1300 87 9,597 110 3 0 2 10,397 120 4 0 2 0.93 0.90 0.88 1500 99 10,647 108 4 0 2 11,593 117 4 0 2 0.93 0.90 0.88 30B 700 70 R2 8,406 120 2 0 2 9,174 131 2 0 3 0.98 0.97 0.96 850 83 9,897 119 2 0 3 10,457 126 2 0 3 0.97 0.95 0.92 1050 105 11,806 112 2 0 3 12,414 118 2 0 3 0.97 0.95 0.92 1300 126 13,675 109 3 0 3 14,964 119 3 0 3 0.93 0.90 0.88 1500 145 15,090 104 3 0 3 16,251 112 3 0 3 0.93 0.90 0.88 700 70 R3 8,539 122 2 0 2 8,893 127 2 0 2 0.98 0.97 0.96 850 83 10,056 121 2 0 2 10,825 130 2 0 2 0.97 0.95 0.92 1050 105 11,936 114 2 0 2 12,748 121 2 0 2 0.97 0.95 0.92 1300 126 13,893 110 3 0 3 14,850 118 3 0 3 0.93 0.90 0.88 1500 145 15,381 106 3 0 3 16,193 112 3 0 3 0.93 0.90 0.88 700 70 R4 8,335 119 2 0 2 8,971 128 2 0 2 0.98 0.97 0.96 850 83 9,877 119 2 0 2 10,589 128 2 0 2 0.97 0.95 0.92 1050 105 11,943 114 2 0 3 12,782 122 2 0 3 0.97 0.95 0.92 1300 126 13,681 109 2 0 3 14,889 118 3 0 3 0.93 0.90 0.88 1500 145 14,952 103 3 0 3 16,463 114 3 0 3 0.93 0.90 0.88 700 70 R5 8,893 127 3 0 2 9,329 133 3 0 2 0.98 0.97 0.96 850 83 10,469 126 4 0 2 11,209 135 4 0 2 0.97 0.95 0.92 1050 105 12,382 118 4 0 2 13,296 127 4 0 2 0.97 0.95 0.92 1300 126 14,453 115 4 0 2 15,254 121 4 0 2 0.93 0.90 0.88 1500 145 15,853 109 4 0 2 16,871 116 4 0 2 0.93 0.90 0.88 Warranty Five-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/resources/terms-and-conditions Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. Please contact your sales representative for the latest product information. AEL Headquarters, 3825 Columbus Road, Granville, OH 43023www.americanelectriclighting.com© 2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. ATB0 02/21/19 Warranty Five-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/resources/terms-and-conditions Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. Please contact your sales representative for the latest product information. AEL Headquarters, 3825 Columbus Road, Granville, OH 43023www.americanelectriclighting.com© 2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. ATB0 02/21/19 Autobahn Series ATB0 Roadway Lighting 3"1-1/2" RAD. 1/4" PLATE 3"8" 1.66 O.D. x .140 WALL TB. 1/4" PLATE.43 x 1-3/4" SLOT 7-1/2""5-1/2"2-7/8" (2 PLCS.) UMR POLE ADAPTOR RECOMMENDED FOR USE WITH POLES OF 4" DIAMETER OR SMALLER UMS POLE ADAPTOR