HomeMy WebLinkAboutR-41810300
d-
O
d-
Q)
W
TESC LEGEND:
SILT FENCE
CLEARING LIMITS
TREE PROTECTION FENCING
CONSTRUCTION ENTRANCE
0 0
o
®
INLET PROTECTION
TREE REMOVAL
APPROXIMATE CUT/FILL VOLUMES
CUT. • = 35t C. Y.
FILL: = 70t C. Y.
(CONTRACTOR TO CONFIRM)
DISTURBANCE AREA
23,642 S.F.
A PORTION OF THE SE 114 OF THE NW 1/4 OF SEC. 05, T. 23 N., R. 05 E., W.M.
KING COUNTY, STATE OF WASHINGTON
I =
CD
z
I
25' 25' 0 5 10 20
I z
LLI SCALE 1 " = 20'
J
o �
TAX PARCEL 052305-9037 TAX PARCEL 052305-9062 -'
CATCH BASIN INSERT PER 1412 N 24TH ST. POWER POLE 2407 MEADOW AVE. N 0 I TAX PARCEL 052305-9041
COR STD PLAN 215.10 Z 1512 N 24TH ST.
R-6 W/ TRANSFORMER, R-6 W I R-6
SDCB EXISTING ACCESS TO BE UTILIZED
RIM=244.55 SITE B.M. #2 4 POWER DROPS AS STABILIZED CONSTRUCTION
IE 8" ABS (N)=241.15 EL.=247.19' & 1 COMM. DROP ENTRANCE. SUPPLEMENT PER W
ASPHALT IE 8" ABS (NW)=241.25 CONC. ° °DETAIL ON SHEET 4 IF NEEDED SITE B.M. 9'
DRIVE DRIVEil"
EL.=256.39'
a ° ° DRIVE CONC.
WALK / \� 3:/ �h
W W W W W W W o w w w w w w w E. 6 STE L WATERMAIN i \
sD - W ^ w w _ W
v X
SD - SD SD 3'g-- SD SD' SD - �. �� c+ a. W W -pw � W
N 24TH �7T:'. _ _ °° EX. 1.6 DUCTILE WATERMAIN
P s ss P P Ro - - _ (RESIDENTIAL COLLECTOR) �\ - W! W -
s SS SS Ss SS - - N8L)2'41"W 744,63'
FOFO FO SS - - -L
- - - - ;- _
Fo FO FO FO FO
0 ku
FO
FO FO HP - - - - - - - - ----.- F0 FO �-
- 3 �
f FO IO0. FO
F
F P O HP OHP - -OAfr OHP OHP \ OHp OHP OHP I Z
Dripline
r I
r � I
k � I
I
I � I
I I
3"
G FL Temporary
I
Chain Link Fence
I
Critical -
r l Root Zane
ti xpar5
-
n NO
One sign per 50 feet ��? TRESSPASSING
t.minimum of 2 signs} PROTECTED
10 Ft. TREES
Figure 1. TREE PROTECTION FENCE DETAIL. DRIPLINE METHOD
A. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCAVATE, STACK OR
STORE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES OR COMPACT THE EARTH IN ANY
WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED.
B. FENCED PROTECTION AREA REQUIRED: PRIOR TO DEVELOPMENT ACTIVITIES, THE APPLICANT
SHALL ERECT AND MAINTAIN SIX-FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION
FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING
THE TREE EQUAL TO ONE AND ONE QUARTER FEET (1-1/4) FOR EVERY ONE INCH (1) OF
TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION
TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50) INDICATING THE
WORDS 'NO TRESPASSING -PROTECTED TREES', OR ON EACH SIDE OF THE FENCING IF LESS
THAN FIFTY FEET (50). SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF
TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4)
SIDES. IN ADDITION THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT OR
TRUCKS ARE MOVING NEAR TREES.
C. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE
RETAINED IS TO BE RAISED, THE APPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK
WELL AROUND THE TREE. THE DIAMETER OF THIS WALL OR WELL MUST BE EQUAL TO THE
TREE'S DRIP LINE.
D. IMPERVIOUS SURFACES PROHIBITED WITHIN THE DRIP LINE. THE APPLICANT MAY NOT INSTALL
IMPERVIOUS SURFACE MATERIAL WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE
TO BE RETAINED, UNLESS OTHERWISE APPROVED BY THE CITY.
E. RESTRICTIONS ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES: THE GRADE LEVEL
AROUND ANY TREE TO BE RETAINED MAY NOT BE LOWERED WITHIN THE GREATER OF THE
FOLLOWING AREAS: 1) THE AREA DEFINED BY THE DRIP LINE OF THE TREE, OR 2) AN AREA
AROUND THE TREE EQUAL TO ONE AND ONE HALF FEET (1-1/2) IN DIAMETER FOR EACH
ONE INCH (1) OF TREE CALIPER. A LARGER TREE PROTECTION ZONE BASED ON TREE SIZE,
SPECIES, SOIL OR OTHER CONDITIONS MAY BE REQUIRED.
F. MULCH LAYER REQUIRED: ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED
COMPLETELY AND EVENLY WITHIN A MINIMUM OF THREE INCHES (3') OF BARK MULCH PRIOR
TO INSTALLATION OF THE PROTECTIVE FENCING. EXCEPTIONS MAY BE APPROVED IF THE
MULCH WILL ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS.
G. MONITORING REQUIRED DURING CONSTRUCTION: THE APPLICANT SHALL RETAIN A CERTIFIED
ARBORIST OR LICENSED LANDSCAPE ARCHITECT TO ENSURE TREES ARE PROTECTED FROM
DEVELOPMENT ACTIVITIES AND/OR TO PRUNE BRANCHES OR ROOTS, FERTILIZE AND WATER AS
APPROPRIATE FOR ANY TREES AND GROUND COVER THAT ARE TO BE RETAINED.
H. ALTERNATIVE PROTECTION: ALTERNATIVE SAFEGUARDS MAY BE USED IF DETERMINED TO
PROVIDE EQUAL OR GREATER TREE PROTECTION WITH APPROVAL FROM THE CURRENT
PLANNING PROJECT MANAGER.
Encompass
ENGINEERING & SURVEYING
Western Washington Division
165 NE Juniper Street, Suite 201 • IssaQuah, WA Y8027 • Phone: (425) 392-0250
Eastern Washington Division
407 Swiftwater Blvd. • Cie Elum, WA 98922 • Phone: (509) 674-7433
IM=261.45
CONCH ASPHALT 88°02'41"E 139.04' z ° °" IE 6, PVC (NE)=253.45
DRIVE DRIVE ° _
IE 8" CONC (W)=253.25
°ii 1 1 20010
SANITARY SEWER x246.170 IzVVV 0 a DRIVE CORNER POWER POLE
SIDE SERVICE SHOWN PT214 SET RBC - - - - x 253.200 ° a 12002 ^,.5' E. & W/POWER &
PER CITY OF RENTON PT218 SRBC ° x 59145 .' N. COMM. DROP
OILP
RECORDS T213 SET RBC F
CLEARING LIMITS
(TYP)
SILT FENCE PER COR
STD PLAN 214.00
1.0
POWER
POLE
W/
CONDUIT
oNP
2�
TAX PARCEL 334450-0235
1409 N 24TH ST.
R-6
WOOD FENCE
CORNER
1. 5' E. &
0.5' S. OF
CORNER
S AME,S
of 1NASX1 �
CID z
38285
1STF
�SSIONAL E��l
o a �
EX HOUSE (TO BE REMOVED) - - - - -
DE K -
V CONC. o CARPORT
P WR. 14-
GATE
° FF EL-
\ CONC. PAD \ 247.63
BENEATH \
- \ DECK \
CHIMNEY PEAK \
EL=272.43 la \ 4
I \
TREE 16"/14 C ERRY \ \�
a
DECK
TREE TO BE REMOVED
(TYP)
TREE PROTEION
FENCE (TYP)
0 9" GWOOD
#7�
CONC.
PAD
EH
II
SHED
12003
S. LINE
OF SHED
1. 1' N.
OF LINE
1011912023 1 No.
X23" ELF/
#6
S.E. CORNER
OF SHED
1. 5' N. OF
LINE
CONW
(DETAC D)
CONC.
FF EL=
HOUSE #1415
SRIVE
255.64
o BEIS'EATH
CARPORp
BRICK a
ROOF PEAK
a
WALL
FF EL_ EL=269.06
a
247.65
ARAGE
C C.
PAD
ONC.
\\
��
STAIRS
WOOD
STAI S
�
#3
(
X,31" MAPLE
1
\1%
I
I
TAX`PARCEL
33 450-0234
C.D. HILL6 N'S LAKE WASHINGTON
GAR EN OF EDE I #5
11" GHESTNU
I
I
II
I
/
II
36" ELM
12004
#4
TAX PARCEL 334450-0250
2219 MEADOW AVE. N
R-6
EROSION PROTECTION NOTE:
L
ALL EXPOSED SOIL AND/OR DISTURBED SURFACES TO BE COVERED WITH MULCH, STRAW, AND/OR PLASTIC SHEETING PER
CONC.
FIG. C.3.4.A AND/OR TABLE C.3.2.A CORSWDM. UNDER NO CIRCUMSTANCES SHALL SOIL STOCKPILES BE LEFT UNCOVERED.
NALL
CONSTRUCTION SEQUENCE:
TAX PARCEL 334450-0230
1. PRE -CONSTRUCTION MEETING.
1509 N 24TH ST.
\ R-6
2. POST NOTICE OF CONSTRUCTION ACTIVITY SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR.
4.7
3. FLAG OR FENCE CLEARING LIMITS.
4. INSTALL CATCH BASIN PROTECTION IF REQUIRED.
5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S).
-
6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
7. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH
\
CLEARING AND GRADING FOR PROJECT DEVELOPMENT.
8. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH CITY OF RENTON EROSION AND SEDIMENT CONTROL
`
STANDARDS.
9. RELOCATE SURFACE WATER CONTROLS AND EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS
S. END
SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY OF
CHAINLINK
RENTON EROSION AND SEDIMENT CONTROL STANDARDS.
FENCE
0.6' E.
10. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAY
OF LINE
DURING WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, OR EQUIVALENT.
11. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS.
12. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. UPON COMPLETION OF THE PROJECT,
ALL DISTURBED AREAS MUST BE STABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE.
/
2005
13. UPON COMPLETION OF THE PROJECT. ALL DISTURBED AREAS MUST BE STABILIZED AND BMP'S REMOVED, IF
252.9-38
APPROPRIATE.
PT216
E. END
CHAINLINK
AROBORIST NOTE:
FENCE
ARBORIST TO BE ON -SITE TO SUPERVISE ALL
0. 6' W. OF
CONSTRUCTION ACTIVITIES BENEATH THE
LINE
DRIPLINES OF RETAINED TREES.
DEMOLITION NOTE:
ALL EXISTING IMPERVIOUS
SURFACES TO BE REMOVED PRIOR
TO THE START OF CONSTRUCTION
AS -BUILT DRAWINGS PLAN
THESE AS -BUILT DRAWINGS AND THE INFORMATION
SHOWN ACCURATELY REFLECT EXISTING FIELD
CONDITIONS AS OF 11/10/22 (DATE SIGNED)
By: KEVI N M. REESE
1011912023
PROFESSIONAL ENGINEER OR DATE
PROFESSIONAL LAND SURVEYOR
SURVEYED:
KMR
SCALE:
1 „=20,
DESIGNED:
SRS
DRAWN:
CVP
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CHECKED:
CJA
REVISION
BY
DATE
A P P R
APPROVED: CJA
Know what's below.
R - 418103 Call before you dig.
VERTICHORIZONTAL: NADVD 1988 991
RCITY OF
RENTON
DATUM NWOF
Planning/Building/Public Works Dept.
N COMPLIANCE WITH CITY OF RENTON STANDARDS
MANGA T SHORT PLAT ASBUIL TS
TESC, DEMOLI TOIN, AND TREE PROTECTION PLAN
d�-
d-
O
O
C�
�M
W
CL
Q
J
0
DATE:
1011912023
FIELDBOOK: N/A
PAGE: NIA
Q
DRAWING NO:
20547
SHEET:3 OF: 9