Loading...
HomeMy WebLinkAboutP_Site Plan_20210922_v2LP HT951 ES LP HT951 ES N SEE C4 FOR FRONTAGE DETAILS Scale: 1" = 5' Frontage Improvement Plan C3 Interlaken Engineering and Design, PLLC Seattle, WA | (206) 470-9572 www.interlakenengineering.com Revisions: 1"=5' 10 5 0 Kumar Residence Interlaken Project No.: SEA-21-004 2021-09-22: Updated for City of Renton Comments Site Address: 14034 SE 159th Pl Jurisdiction: Renton Parcel No.: 510445-0950 Applicant: Ken Kumar Permit No.: PR21000138/ B21001611 N 71.88'130.25'56.95' r=254.93' 18.99'145.96'4'40'3'-6"5' 5'20'6'19'-8"30'-11"21'-6"9'20'Site Plan - CHD-30068921-S Scale: 1" = 20'-0" SE 159th Place Driveway 2 Car Garage Proposed House Ken Kumar14034 SE 159th PlaceRenton, WA ZipPhoneParcel # - 5104450950Ken KumarPrinted On: 9/7/2021 14:58:52 Sheet: CHD Job #: 99-9999 2102 E Main #202Puyallup, WA 98372Jared Baehmer, OwnerPh: 866.657.4371Disclaimers:---These plans are exclusive property of Cornerstone Home Designs (CHD) and may not be sold to any person or business without expressedwritten consent of CHD. These plans are for one (1) time use only for CHD's customer - Ken Kumar and to be built on the customer's site at14034 SE 159th Place in Renton, WA Zip.---NOTICE: DO NOT SCALE - The written dimensions on this plan supersede any scaled measurements.---Copyright notice: these plans are copyrighted and are subject to copyright protection as an "architectural work" under sec. 102 of thecopyright act, 17 USC as amended December 1990. The protection includes but is not limited to the overall form as well as the arrangementand composition of spaces and elements of design. Under such protection, any unauthorized use of these plans, the design in whole or part,can legally result in monetary compensation to CHD. Written permission must be obtained and granted prior to any use and/or designchanges to these plans.---Any variations from conditions and dimensions shown on the drawing shall be reported to the designer for resolution prior to proceedingwith the work, otherwise the contractor shall be solely responsible for costs of any necessary remedial work.SITE ANALYSIS PROPERTY Property Area = Setback Area = Buildable Area = ------------------------------------------------------------- HABITABLE - Proposed 1st Floor = - Proposed 2nd Floor = - Proposed Basement = Total Habitable = ------------------------------------------------------------- IMPERMEABLE & PERMEABLE - Existing Driveway = - Proposed 1st Floor = - Proposed Deck (front) = - Proposed Deck (rear) = - Proposed Deck (side) = - Proposed Garage = Total Impermeable = Permeable Area = Total Impermeable / Property Area ------------------------------------------------------------- LOT COVERAGE (Structures over 42" High) - Proposed 1st Floor = - Proposed Deck (front) = - Proposed Deck (rear) = - Proposed Deck (side) = - Proposed Garage = Total Coverage = Total Coverage / Property Area 9991 Sq.Ft. 6063 Sq.Ft. 3928 Sq.Ft. 2308 Sq.Ft. 2308 Sq.Ft. 1724 Sq.Ft. 6340 Sq.Ft. 609 Sq.Ft. 2308 Sq.Ft. 72 Sq.Ft. 240 Sq.Ft. 343 Sq.Ft. 464 Sq.Ft. 4036 Sq.Ft. 5955 Sq.Ft. (4036 / 9991) = 40.4% 2308 Sq.Ft. 72 Sq.Ft. 240 Sq.Ft. 343 Sq.Ft. 464 Sq.Ft. 3427 Sq.Ft. (3427 / 9991) = 34.3% Layout Sheet # 1 of 1 Site Plan A0.1