SECTION A
L
A L = THE D/STANCE SUCH THAT POINTS
/ A AND B ARE OF EQUAL ELEVATION
BOTTOM OF DITCH
18' MIN.
ASBUILT TESC NOTES AND DETAILS
OF
EDENFIELD (SUMPTER) SHORT PLAT
A PORTION OF SECTION 14, TOWNSHIP 23 N., RANGE 05 E., W.M.
CITY OF RENTON, KING COUNTY, WASHINGTON
NOTES:
1. CONDITIONS OF USE
1.1. WHERE THERE IS CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM SEDIMENT PONDS OR TRAPS.
1 2. TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON -EROSIVE DISCHARGE POINT
2. MAINTENANCE STANDARDS
2_1 ANY SEDIMENT DEPOSITION OF MORE THAN 6INCHES SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY.
2.1 THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS IF SCOURING AND EROSION HAS OCCURRED,
AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET OR NET
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
STD. PLAN - 217.40
PUBLIC WORKS PPR °i
DEPARTMENT DITCH CHECK DAMS GqZ 9/28/2018 I
DATE
DocuSign Envelope lD:6EECF586-602A-4E4A-B436-A317AA638878
2
2 MAx _
LEVEL BOTTOM kiAX
1
12' MIN
2' MIN. +�
-� SWALE SPACING DEPENDS ON SLOPE GRADIENT
NOTES:
1. CONDITIONS OF USE
1 1. REQUIRED A7
1 1 1 THE TOP OF ALL SLOPES IN EXCESS OF 3H 1V AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF
1.1.2. AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELOW,
AVERAGE SLOPE
SLOPE PERCENT
FLOW PATH LENGTH
20H-1V (OR LESS)
3_5 %
3DO FEET
00 TO 20)H.-1V
5-10%
2DO FEET
(4 TO 10)H-1V
10-25%
100 FEET
(2TO4)H:/V
25.5D%
50FEET
2. DESIGN AND INSTALLATION SPECIFICATIONS
2A FOR SLOPES STEEPER THAN 2H.1 V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED
INTERCEPTOR SWALES MAY BE USED THE DESIRED MEASURE MUST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VE! 01-ITY
RUNOFF TO A SEDIMENT POND OR TRAP.
2.2. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED.
3. MAINTENANCE STANDARDS
31 DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY.
3.2 IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF. THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED.
STD. PLAN - 217.10
PUBLIC WORKS
DEPARTMENT INTERCEPTOR SWALE GqZ 9/28/2018 I
DATE
:45 AN
:45 AN
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
DocuSign Envelope ID: 6EECF586.602A-4E4A.B436-A317AA638878
DRAINAGE GRATE
SEDIMENT AND DEBRIS
FILTERED I
WATER -J
SECTION VIEW
DRAINAGE GRATE
(RECTANGULAR GRATE SHOWN)
BELOW INLET GRATE DEVICE
s^ MAx.
TWIN
OVERFLOW BYPASS
BELOW INLET GRATE DEVICE
RETRIEVAL SYSTEM (TYP.)
OVERFLOW BYPASS(TYP)
ISOMETRIC VIEW
NOTES:
1, PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 50D FEET OF A DISTURBED OR
CONSTRUCTION AREA. UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP
2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM.
3- THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE.
4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE.
5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS),
6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL,
7 PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(16).
8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE
STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY.
UNLESS OTHERWISF NDTED. DRAWING IS NOT TO SCALE (NTS)
VRI
STD. PLAN - 216.30
PUBLIC WORKS "Pa .m
DEPARTMENT CATCH BASIN INSERT GqZ 9/28/2018 I
DAR
4' MIN,
12'OVERFLOW
/T DEPTH 2`- 4^ ROCK
DEPTH
OUTFLOW CHANNEL IF
24' MIN. SETTLING DEPTH
CONSTRUCTED BY
0
EXCAVATION
~
�
r
\
3.5'T S, �--�
S MAX
`-
1
FILTER FABRIC FENCING
1.5' MIN SEOIMENI STORAGE
12^ DEPTH 3''4" - 1 112^
WASHED GRAVEL
CROSS SECTION
1
NOTES:
I MAYBE CONSTRUCTED BY EXCAVATION OR BY BUILDING A BERM
'.INLESS OTHERWISE NOTED, DRA WING IS NOT TO SCALE (NTS)
STD. PLAN - 211.00
i_ PUBLIC WORKS m °
DEPARTMENT SEDIMENT TRAP GqZ 9/28/2018 1
DATE
:45 AN
:45 AI
DocuSign Envelope lD:6EECF586-602A-4E4A-B436-A317AA638878
Eyy5j1NC'ROk7GV \
R = 25' MIN
1. DRIVEWAYS SHALL BE PAVED TO
THE EDGE OF THE RIGHT-OF-WAY
PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO
AVOID DAMAGING OF THE
ROADWAY.
2. IT IS RECOMMENDED THAT THE
ENTRANCE BE CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
16 MIN
PROVIDE FULL WIDTH OF
T INGRESS(EGRESS AREA
12' MIN. THICKNESS J
NOTES:
I.CONDITION OF USE
/ 1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER
PAVED AREAS WITHIN 1.000 FEET OF THE SITE.
12 FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION
ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTRWIDTH TO PROVIDE VEHICLE ACCESSPARKING, BASED ON LOT SIZE)CONFIGURATION,
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1, A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE
SHALL MEET THE FOLLOWING STANDARDS.
GRAB TENSILE STRENGTH(ASTM D4632)
200 LBS. MIN
GRAB TENSILE ELONGATION (ASTM D4632)
30%MAX. (WOVEN)
CBR PUNCTURE STRENGTH (ASTM D6241)
495 LSS MIN
ADS (ASTM D4751)
12G45 (U.S. STANDARD SIEVE SIZE)
2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE PH
LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED.
2.3. Moo FUEL (WOOD BASED MULCH) MAY SUBSTITUTED FOR OR COMBINED WITH QUARRY SPACES IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS.
HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS
IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM. COMPACTED SUBGRADE THIS CAN SUBSTANTIALLY INCREASE THE
EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
32 IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF
SEDIMENT SHALL BE USED, THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL
WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3, ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING THE SEDIMENT COLLECTED BY SWEEPING SHALL BE
REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND
THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE
WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND
CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS.
3.4, ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UPON THE ROADWAY SHALL BE REMOVED IMMEDIATELY
3 5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S). FENCING SHALL BE INSTALLED TO CONTROL
TRAFFIC
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 215.10
PUBLIC WORKS APPROVED
DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 1
DATE
1 RECORD DRAWINGS AS BUILT TJS 110/10/22 BJT 511WE"M'
DEM RK
BENCHMARK DRAWN:
DATUM DOMEDIN CONCRETE MONUMENT
IN BRASS DOMESS FOUND�INARK 4X41 0.4 CK CHERK
HORIZONTAL DATUM: VERTICAL DATUM: CASE 0.5" BELOW GRADE OBSERVED BELOW GRADE OBSERVED 37555 BJT
NAD '83/'91 NAVD '88 N: 175866.55, E: 1319201.78 N: 175852.22, E: 1319809.82 N0. REVISION BY DATE APPR 'IPR°VMBJT
N/A
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
NDR¢oNrAL NAD 1919
83 1991
DATU M
I IJ V/1. V/1LV/11NILLU TTIRL I I
II II
I,�I STEEL FENCE POST 6' HIGH MIN. u
NOTE:
1: CLIP FENCE TO GALVANIZED WIRE @ 5 FOOT ON -CENTER SPACING
2. WIRE FENCE TO STEEL FENCE POST
TEMPORARY N.G.P.E. FENCE DETAIL
NOT TO SCALE
:45 CALL BEFORE YOU DIG:
1-800-424-5555
AaaibiiI
CI TY OF
RENTON
Planning/Building/Public Works Dept.
3. AL
O
z
� J 1423
o�F /ST�
ss/DNA
L
0/10/20
C
0
YI
L
O
•�
/m/omI�
if
C
L u
c:
�
N
M
�
C
QOC)ON
Q
Ln
O
LO
/c�v
W
U
CO
r
a)
Y
N
R-418808
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
ASBUILT TESC NOTES
AND DETAILS
EDENFIELD (SUMPTER) SHORT PLAT
MAINVUE WA LLC
1110112TH AVE NE, SUITE 202