Loading...
HomeMy WebLinkAboutR-419007NW 1/4 OF THE NW 1/4 AND THE NE 1/4 OF THE NW 1/4 SECTION 9, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M. T I W I— Q fY W I rO VJ or U 0 0 I N DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SEDIMEN' DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) BELOW INLET GRATE DEVICE ISOMETRIC VIEW sS TE DEVICE RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) NOTES: 1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 216,30 PUBLIC WORKS APPR ED: PRDEPARTMENT CATCH BASIN INSERT (jAZ 9/28/2018 VAMOV Pubic Wu,k, Adm --t., DATE CATCH BASIN INSERT NTS 3 C3.00 :45 AP DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 LEVEL BOTTOM 12" 'AIN. 2' MIN. SWALE SPACING DEPENDS ON SLOPE GRADIENT 2 2 MAX. MAX. -11 1 1. CONDITIONS OF USE 1.1. REQUIRED AT: 1.1.1. THE TOP OF ALL SLOPES IN EXCESS OF 3H:1V AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF. 1.1.2. AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELOW. AVERAGE SLOPE SLOPE PERCENT FLOW PATH LENGTH 20HA V (OR LESS) 3-5 % 300 FEET (10 TO 20)H:1 V 5-10 % 200 FEET (4TO10)H:1V 10-25% 100FEET (2 TO 4)H:1 V 25-50 % 50 FEET 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. FOR SLOPES STEEPER THAN 2H:1 V WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED INTERCEPTOR SWALES MAY BE USED. THE DESIRED MEASURE MUST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY RUNOFF TO A SEDIMENT POND OR TRAP. 2.2. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED. 3. MAINTENANCE STANDARDS 3.1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. 3.2. IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 217.10 PUBLIC WORKS D. INTERCEPTOR SWALE PPR 9/28/2018 DEPARTMENT GAZ Pubic Works Admini t-.1 DATE INTERCEPTOR SWALE NTS • Call 811 • ® two business days before you dig 1 CLEAR AND GRADE PERMIT TJP 08/10/211 JSF 2 CLEAR AND GRADE PERMIT RESUBMITTAL TJP 08/11/21 JSF 3 CLEAR AND GRADE PERMIT RESUBMITTAL TJP 09/10/21 JSF NO. REVISION BY DATE APPR 4 C3.00 :45 AN SURVEYED: SCALE: ZLN AS NOTED DESIGNED: TJP/JRN DRAWN: TAD/KSA ONE INCH CHECKED: MNF AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY APPROVED: JSF DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 0— K oc FLOW uy OO <5OOo PLAN SECTION B DITCH CHECK DAM (TYP.) NOTES: 1. CONDITIONS OF USE 1.1. WHERE THERE IS CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM SEDIMENT PONDS OR TRAPS. 1.2. TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON -EROSIVE DISCHARGE POINT. 2. MAINTENANCE STANDARDS 2A1 ANY SEDIMENT DEPOSITION OF MORE THAN 6 INCHES SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY, 2.2. THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION HAS OCCURRED, AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET OR NET. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 217.40 PUBLIC WORKS DITCH CHECK DAMS PPR D. 9/28/2018 PRI DEPARTMENT GAZ Pubic Woks Ad.,--m, DATE CHECK DAM NTS R-419007 5 C3.00 :45 AN IN COMPLIANCE WITH CITY OF RENTON STANDARDS jKPff EDEVEiLOPMENT ENGINEERINGIL Ekreva:rns E WATER UTILITY o 09/27/2021 09/27/2021 ' 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 09/10/2021 www•kpff.com VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 A11016[% I CITY OF ;R RENTON DATUM • Planning/Building/Public Works Dept. SOLERA 2842 NE SUNSET BLVD RENTON, WA 98056 TESC DETAILS DATE: PAGE: C3.1 1 SHEET: OF: 7 9 T N U J