HomeMy WebLinkAboutEx02_Building_Elevations,_3D_Views_and_Floor_Plans1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4"8' - 0"10' - 1 3/4"PLATE HT 184' - 9 3/4" ROOF DECK 186' - 3" 5'0x3'0 5'0x3'0 4'0x4'6 6'0X4'02'6x3'0 5'0x2'0 2'6x3'0 SG SG SG 5'0x4'0 E 16"x8" CRAWL SPACE VENT, TYP.5' - 0"7' - 0"4' - 0"3' - 0"5' - 0"8' - 0"5' - 0"5' - 0"3' - 6"4' - 0"EXISTING GRADE 3' - 0"5'0x4'0 18' - 1 3/4"8' - 2 1/2" WALL AREA: 18.1' x 8.2' = 148.4 SF PER IRC R302.1(1), 25% MAX OPENING IN WALL ALLOWED WHEN WALL IS 3-5' TO PROPERTY LINE. MAX ALLOWED: 148.4 X 0.25 = 37.1 SF PROPOSED OPENING AREA: (5' x 4') + (5' x 3') = 35 SF --> OK 5'0x2'0 R 3' - 0"R 3' - 0"R 3' - 0" 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" PLATE HT 184' - 9 3/4"10' - 1 3/4"8' - 0"ROOF DECK 186' - 3" 4 " / 1 '-0 " 8'0x6'0 8'0x5'0 5'0x3'04'0x4'6 3'0x5'0 3'0x5'0 3'0x5'0 3'0x5'0 SG E 1' - 10"TRANSPARENT FASCIA-MOUNT CABLE RAILING, MIN 3' ABOVE FINISHED FLOOR, TYP.8' - 0"3' - 0"3' - 6"4' - 0"2' - 0"3' - 0"EXISTING GRADE 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" AVG GRADE 164' - 3 3/8" MAX RIDGE HT 194' - 3 3/8"8' - 0 1/4"1' - 5 1/4"8' - 0"10' - 1 3/4"MAX PLATE HT 188' - 3 3/8"6' - 0"24' - 0"PLATE HT 184' - 9 3/4" ROOF DECK 186' - 3" 3 1 /2 " / 1 '-0 " 5'0x3'0 3'0x5'0 3'0x5'0 8'0x4'6 6'0x8'0 5'0x5'0 4'0x3'0 3'0x7'0 SG SG SG SG CRAWL SPACE ACCESS, MIN OPENING OF 18" X 24", WITH 16"X8" CRAWL SPACE VENT IN DOOR8' - 0"3' - 0"7' - 0"4' - 0"2' - 6"5' - 0"8' - 0"3' - 0"PROPOSED DOWNSPOUT TO THE APPROVED POINT OF DISCHARGE, TYP. EXISTING GRADE R 3' - 0" R 3' - 0" 1ST FLOOR 166' - 8" 2ND FLOOR 176' - 9 3/4" AVG GRADE 164' - 3 3/8" MAX RIDGE HT 194' - 3 3/8" MAX PLATE HT 188' - 3 3/8"6' - 0"24' - 0"PLATE HT 184' - 9 3/4"9' - 5 1/2"8' - 0"10' - 1 3/4"ROOF DECK 186' - 3" 4" / 1'-0" 3 1 /2 " / 1 '-0 " 3'0x8'01'0x8'0 16'0x8'0 6'0x5'0 5'0x5'09'0x7'0 1'0x8'0 EXISTING GRADE PROPOSED GRADE SG SG SG SG SG E E 6'0x5'0 E 3' - 0"8' - 0"3' - 0"8' - 0"3' - 0"1' - 6" METAL SIDING HARDIE PANEL SIDING, TYP. HARDIE LAP SIDING, TYP.36" MIN., TYP.36" MIN., TYP.COMPOSITE SHINGLE ROOF OVER (2) LAYERS 30# BLDG PAPER, TYP. WINDOWS TO HAVE U-FACTOR 0.28 FIELD VERIFY THIS HIGHER STANDARD 1 DATE: PROJECT NO: SCALE: DRAWN BY: 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CB ANDERSON ARCHITECTS SHEET TITLEREVISIONS: PLLC.NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEETCOPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" X 36".CLIENT: CONSULTANT: Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 Straight Arrow Homes, LLC 12015 NE 8th Street, Suite 5 Bellevue, WA 98005 PR21000259 B21005267 1/4" = 1'-0" A-5 AMSTRAIGHT ARROW N 35TH ST RENTONELEVATIONS1951.0 01 OCTOBER 20211218 N 35th StreetRenton, WA 98056SCALE: 1/4" = 1'-0" EAST ELEVATION SCALE: 1/4" = 1'-0" NORTH ELEVATION SCALE: 1/4" = 1'-0" WEST ELEVATION SCALE: 1/4" = 1'-0" SOUTH ELEVATION ROOF INSTALLATION NOTE PER IBC 1507.2.2 FOR ASPHALT SHINGLE INSTALLATIONS BETWEEN 2:12 AND 4:12 SLOPES, PROVIDE (2) LAYERS UNDERLAYMENT MEETING AND CONFORMING TO CODE STANDARDS. FASTENERS & FLASHING TO BE PER SBC 1507. E EGRESS WINDOW MIN. 5.7 SF NET OPENING (MIN. 24" HIGH, 20" WIDE) SG SAFETY GLAZING LEGEND SIDING MATERIAL AND COLORS: MANUFACTURED SIDING TO BE INSTALLED PER INDUSTRY BEST PRACTICE AND MANUFACTURER’S RECOMMENDATIONS. FLATNESS TOLERANCE TO BE < 1/8” OVER 10’. LAP SIDING · 5/16” SMOOTH FIBER CEMENT LAP SIDING · MANUFACTURER: JAMES HARDIE · 4” EXPOSURE · PAINT: BENJAMIN MOORE CHELSEA GRAY HC-168 PANEL SIDING W/ REVEALS · 5/16” SMOOTH FIBER CEMENT PANELS · MANUFACTURER: JAMES HARDIE · PAINT: BENJAMIN MOORE BLACK IRON 2120-20 · PANEL TRIM BY FRY REGLET, OR APPROVED EQUAL PER OWNER PLATE HEIGHT NOTES: MAX HEIGHT FROM AVERAGE GRADE LEVEL (SEE CALCULATIONS SHEET A-1.0) TO PLATE HEIGHT IS 24'-0" PLUS 6' ADDITIONAL FOR A PITCHED ROOF W/ MIN 4:12 SLOPE. CONTRACTOR IS RESPONSIBLE TO MONITOR CONSTRUCTION & COMPLETION TO ENSURE COMPLIANCE. ELEVATION NOTES: 1. PROVIDE FLASHING AT ALL DOORS, WINDOW AND HORIZONTAL TRIM TRANSITIONS, TYP. FLASH AT ALL ROOF VALLEY CONDITIONS, ALL WALL TO ROOF AND WALL TO DECK CONDITIONS, DECK WATERPROOFING TO BE WARRANTED, TYP. 2. INSTALL MANUFACTURED SIDING PER MANUFACTURER'S GUIDELINES AND CEDAR SIDING PER WESTERN RED CEDAR LUMBER ASSOCIATION GUIDELINES, TYP. 3. GUTTERS & DOWNSPOUTS TO LEAD TO TIGHTLINE CONNECTION TO CITY APPROVED DRAINAGE SYSTEM CASEMENT OR AWNING WINDOWS USED FOR EGRESS MUST INCLUDE HARDWARE THAT ALLOWS THE WINDOW TO OPEN A MINIMUM OF 90 DEGREES AND PROVIDES FULL WIDTH CLEARANCE IN FULLY OPEN POSITION. GUARDRAIL NOTE: - GUARDS DESIGNED TO RESIST A 200 LB CONCENTRATED LOAD ON THE TOP RAIL AND 50 PSF ON ALL GUARDRAIL INFILL COMPONENTS, TYP. - PROVIDE GUARD RAIL IF THERE IS MORE THAN 30" LEVEL CHANGE, GUARD RAIL HEIGHT TO BE 36" MIN. W/ LESS THAN 4" BTWN BALUSTERS, TYP. EXHAUST DUCT OUTLETS MUST TERMINATE NOT LESS THAN 3' FROM OPENINGS INTO BUILDINGS, TYP. METAL SIDING · 24 GAUGE STEEL, FLAT SHEET · MANUFACTURER: THE BRYER COMPANY · PAINT: NIGHT SKY, NATURAL FX COATING SOFFIT · CEDAR T&G W/ CLEAR COAT FASCIA · PAINT: BENJAMIN MOORE BLACK IRON 2120-20 Notes: - Follow all installation instructions per manufactures. 1 27 DECEMBER 2021 RECEIVED Clark Close 01/24/2022 PLANNING DIVISION Exhibit 2 DocuSign Envelope ID: BE699953-BA0C-4D42-93F9-BAF4560A83BC DATE: PROJECT NO: SCALE: DRAWN BY: 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CB ANDERSON ARCHITECTS SHEET TITLEREVISIONS: PLLC.NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEETCOPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" X 36".CLIENT: CONSULTANT: Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 Straight Arrow Homes, LLC 12015 NE 8th Street, Suite 5 Bellevue, WA 98005 PR21000259 B21005267 A-6 AMSTRAIGHT ARROW N 35TH ST RENTON3D VIEWS1951.0 01 OCTOBER 20211218 N 35th StreetRenton, WA 980563D View 3 3D View 1 3D View 2 3D View 4 DocuSign Envelope ID: BE699953-BA0C-4D42-93F9-BAF4560A83BC UP SMOKE DETECTOR EXHAUST FAN WITH CFM CALL-OUT BELOW SD EGRESS WINDOW MIN. 5.7 SF NET OPENING (MIN. 24" HIGH, 20" WIDE) E SAFETY GLAZINGSG CLOSETCLST. SDC COMBINED SMOKE DETECTOR & CARBON MONOXIDE ALARM HEAT DETECTORHD60' - 0"50' - 0"7' - 0"26' - 6"13' - 6" 19' - 0 1/2"8' - 3 1/2"6' - 8 1/2"11' - 5 1/2"5' - 6"7' - 3 1/2"3' - 6"3' - 6"22' - 8 1/2"7' - 7"4' - 6"9' - 0"16' - 11"9' - 0"7' - 0" 40' - 0"12' - 0"5' - 11"6' - 0"29' - 1"1' - 0" 1' - 6" 4' - 3"12' - 0"4' - 3" 2' - 3"9' - 0"2' - 3" 1' - 4" GARAGE OFFICE/ JUNIOR SUITE LIVING DINING KITCHEN UP UP 6R DN COAT 5' - 6"4' - 6" 4' - 8 1/2" BATHROOMPOWDER 2' - 1"2' - 7" COVERED PATIO 3' - 7"19' - 1 1/2"STORAGE 19' - 6 1/2"17' - 7"30" PANTRY A A-4 COV. PORCH CABINETRYCONCRETE 36" REF.30" DW13' - 6"5' - 0"1' - 0" WOOD FRAME ROOF ABOVE DECORATIVE OR STRUCTURAL BEAMS ABOVE CONCRETE 3' - 6"1/4" / FOOT SLOPEDECK EDGE ABOVE 1' - 6"20' - 1"8' - 2 1/2"28' - 8 1/2"1' - 6"2' - 6"6' - 0"10' - 11"4' - 0"5' - 3 1/2"1' - 7 1/4"5' - 0"1' - 7 1/4"2' - 6"2' - 6"6' - 7"5' - 0"3' - 6"1' - 6"6' - 0"1' - 6" 2' - 0"16' - 0"2' - 7 1/2"5' - 3"7 1/2" 2' - 0"8' - 0"2' - 0" 3' - 3 3/4"3' - 0"3 1/2"3' - 0"3 1/2"3' - 0"3 1/2"3' - 0"3' - 3 3/4"1' - 4"6' - 0"1' - 8"1' - 3"3' - 0"1' - 8"10' - 6"5' - 0"9' - 4"3' - 0"1' - 3"4' - 0"WHTANKLESS WATER HEATER 50 FACTORY BUILT FIREPLACE TO BE UL LISTED, LABELED AND INSTALLED WITH CONDITIONS OF LISTING. FACTORY BUILT FIREPLACE MUST BE TESTED IN ACCORDANCE WITH UL 127, WASHINGTON CERTIFIED GAS FIREPLACE. SEPARATE GARAGE FROM LIVING SPACE WITH * NOTE THIS SHEET. R-21 INSUL. AT WALL AND R-38 INSUL. AT CEILING BTWN. GARAGE & HEATED SPACE, TYP. * SLAB ON GRADE 1/8" SL/FT.EXHAUST DUCT OUTLETS AT 1ST FLOOR TERMINATE OUT WALL, TYP. CRAWL SPACE ACCESS, MIN OPENING OF 18" X 24", WITH 16"X8" CRAWL SPACE VENT IN DOOR 50 100 2'10X6'8 2'6x6'82'6x6'82'6x6'8 3'0x8'01'0x8'0 16'0x8'0 6'0x5'0 5'0x3'05'0x3'03'0x5'03'0x5'04'0x4'62'6x6'88'0x6'0 6'0X4'02'6x3'02'6x6'86'0x8'01'0x8'0 3'0x5'0 3'0x5'0 3'0x5'0 3'0x5'0 3' sill @ landingCLST. *SGSGSGSG SGE SDC SD MIN 36" HIGH GUARDRAIL, TYP. SG B A-4 19' - 6"1/4" / FT. SLOPE16"x8" CRAWL SPACE VENT, TYP. 1-HOUR RATED WALL ASSEMBLY WITHIN 2-5' FROM PROPERTY LINE 1-HOUR RATED WALL ASSEMBLY WITHIN 2-5' FROM PROPERTY LINEPRE-CAST CONCRETE STAIR TREADS, WOOD STRINGERS PER STRUCTURAL, TYP. 16"x8" CRAWL SPACE VENT, TYP. 6' - 5"3' - 10" WALL ABOVE A-8 10 A-8 9 A-9 3 A-9 7 A-8 11 HD 5'0x4'0 SGA-8 10 TYP.3' - 0"DN 14' - 4 1/2"19' - 2 1/2" 12' - 7 1/2"11' - 5 1/2"5' - 6"WD19' - 6"9' - 3"9' - 0"2' - 3"1' - 6"MASTER BEDROOM COVERED DECK BEDROOM 38' - 0"13' - 11"5' - 0"7' - 3 1/2"BATHR. W.I.C. MASTER BATHROOM LINEN 2' - 1"6' - 8"7' - 0"5' - 6"5' - 8 1/2" 13' - 3 1/2" 5' - 0"8' - 3 1/2"11' - 8 1/4"2' - 1"2' - 1"11' - 8 1/4"4' - 6" 3' - 0"4' - 6" LINEN BEDROOM 2 CLOSET CLOSET BEDROOM 1 LAUNDRY CLOSET COMMON SPACE/ DEN3' - 6"6' - 0"10' - 2"DN 3' - 1"6' - 4"5' - 0"4' - 0" A A-4 60" TUB 4'X6' SHOWER 5' - 0"7' - 7 1/2"10' - 1 1/2"3' - 6"2' - 1"1' - 9" WALL BELOW 3' - 6"5' - 0"6' - 7"2' - 6"2' - 6"1' - 7 1/4"5' - 0"1' - 7 1/4"4' - 3 1/2"5' - 0"10' - 11"5' - 0"3' - 6"1' - 6"20' - 1"8' - 2 1/2"28' - 8 1/2"58' - 6"1' - 6"4' - 0"3' - 6"8' - 0"3' - 6" 19' - 6"20' - 6" 1' - 9"5' - 0"12' - 9"3' - 6"8' - 0"16' - 10"4' - 0"1' - 8"40' - 0" 1' - 5"5' - 0"2' - 10"1' - 6"6' - 0"1' - 6"11' - 0"34' - 0"1' - 5"5' - 0"2' - 7"9' - 0"2' - 0"9' - 0"8' - 6" E 2'8x6'8 2'6x6'8 2'4x6'8 2'4x6'85'0x3'05'0x5'0 5'0x2'08'0x5'0 8'0x4'62'6x6'8 5'0x6'82'6x6'82'6x6'82'6x6'82'8x6'85'0x6'8 5'0x6'8 2'6x6'8 2'10x6'85'0x3'0 5'0x5'02'4x6'8 4'0x4'6 4'0x3'03'0x7'0 9'0x7'0 SG SG2'6x3'0SG SG SGSGE EE 50 90 50 50 CONTINOUS WHOLE HOUSE FAN EXHAUST DUCT OUTLETS AT 2ND FLOOR TERMINATE OUT ROOF, TYP. SDC SD SD SD SD MIN 22"X30" ATTIC ACCESS W/ R-38 INSULATION PER DETAILS MIN 36" HIGH GUARDRAIL, TYP. ROOF ABOVE ROOF ABOVE 1' - 4" 6'0x5'03' - 5"5'0x4'0B A-4 1-HOUR RATED WALL ASSEMBLY WITHIN 2-5' FROM PROPERTY LINE 1/4" / FT. SLOPE5" FASCIA GUTTER, TYP. FACE-MOUNTED METAL GUARDRAIL PER STRUCTURAL, MIN 36" ABOVE FFE, TYP. MEMBRANE DECKING PER DETAILS, SLOPE 1/4"/ FT. , TYP. 1-HOUR RATED EAVE REQ'D WHEN LESS THAN 5' FROM PROPERTY LINE, TYP. 7' - 4"3' - 10" 5" DN A-9 5 A-10 2 CODE COMPLIANT PREFAB METAL SPIRAL STAIRS BY OTHERS, INSTALL PER MANUFACTURER, SEE NOTES ON SHEET A-43 1/2" / 1'-0"2'X4' SKYLIGHTS 5'0x2'0MIN R-38 INSULATION REQUIRED @ ROOF A-8 7 DATE: PROJECT NO: SCALE: DRAWN BY: 7209 Greenwood Avenue North Seattle, Washington 98103 206-782-2911 Fax 782-5624 CB ANDERSON ARCHITECTS SHEET TITLEREVISIONS: PLLC.NOT FOR CONSTRUCTION UNLESS CITY APPROVAL STAMP APPEARS ON THIS SHEETCOPYRIGHT CB ANDERSON ARCHITECTS. ALL RIGHTS RESERVED. NOT TO BE REPRODUCED WITHOUT PERMISSION. ORIGINAL SHEET SIZE 24" X 36".CLIENT: CONSULTANT: Equilibria Structural Engineering 9999 Harbour Place, Suite 107 Mukilteo, WA 98275 360-386-9476 Straight Arrow Homes, LLC 12015 NE 8th Street, Suite 5 Bellevue, WA 98005 PR21000259 B21005267 1/4" = 1'-0" A-3 AMSTRAIGHT ARROW N 35TH ST RENTONFLOOR PLANS1951.0 01 OCTOBER 20211218 N 35th StreetRenton, WA 98056LEGEND NORTH SCALE: 1/4" = 1'-0" 1ST FLOOR SCALE: 1/4" = 1'-0" 2ND FLOOR NORTH WHOLE HOUSE FAN VENTILATION CONTINUOUS WHOLE HOUSE FAN MIN 90 CFM SEE SHEET A-2 VENTILATION & AIR QUALITY NOTES GUARDRAIL NOTE: - GUARDS DESIGNED TO RESIST A 200 LB CONCENTRATED LOAD ON THE TOP RAIL AND 50 PSF ON ALL GUARDRAIL INFILL COMPONENTS, TYP. - PROVIDE GUARD RAIL IF THERE IS MORE THAN 30" LEVEL CHANGE, GUARD RAIL HEIGHT TO BE 36" MIN. W/ LESS THAN 4" BTWN BALUSTERS, TYP. EXHAUST DUCT OUTLETS MUST TERMINATE NOT LESS THAN 3' FROM OPENINGS INTO BUILDINGS, TYP. SMOKE ALARMS: - SMOKE ALARMS SHALL NOT LOCATED WITHIN 3' OF A DOOR OR OPENING OF A BATHROOM OR SHOWER ROOM. - IONIZATION SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 20 FEET OF A PERMANENT INSTALLED COOKING APPLIANCE. THE DISTANCE IS CUT IN HALF TO 10 FEET FOR IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH. - PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 6 FEET OF A PERMANENT INSTALLED COOKING APPLIANCE. ENERGY CODE NOTES: PER ENERGY CREDIT OPTION 5.5: ELECTRIC HEAT PUMP WATER HEATER MEETING THE STANDARDS FOR TIER I II OF NEEA'S ADVANCED WATER HEATING SPECIFICATION CRAWL SPACE VENT CALCULATION: 1500 SF / 300 = 5 SF X 144 IN. = 720 SQ IN / 72.5 SQ. IN. (16"X8" VENT) = 9.93 PROPOSED: (10) 16"X8" VENTS GARAGE AREA SEPARATION NOTES 1. GARAGE SHALL BE SEPARATED FROM RESIDENCE BY 1/2" TYPE 'X' GWB @ WALLS. 2. GARAGE BELOW HABITABLE ROOM SHALL BE SEPARATED BY (2 LAYERS) 5/8" TYPE 'X' GWB FOR TJI FRAMING, (1 LAYER) 5/8" TYPE 'X' GWB FOR SOLID LUMBER. 3. STRUCTURE SUPPORTING FLOOR-CEILING ASSEMBLY SHALL BE PROTECTED BY 1/2" TYP 'X' GWB. 4. 20 MINUTE OR SELF-CLOSING, TIGHT FITTING, 1 3/8" SOLID CORE DOOR, TYP. AT GARAGE TO LIVING SPACE. NOTES: R303.7 INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT- CANDLE (11 LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. R303.8 EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. R303.7.1 WHERE LIGHTING OUTLETS ARE INSTALLED IN INTERIOR STAIRWAYS, THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHTING OUTLET WHERE THE STAIRWAY HAS SIX OR MORE RISERS. THE ILLUMINATION OF EXTERIOR STAIRWAYS SHALL BE CONTROLLED FROM INSIDE THE DWELLING UNIT. STAIR NOTE: 7-3/4" MAX. RISER HEIGHT AND MIN. 10" TREAD DEPTH CONTINUOUS 1.5" DIA. HANDRAIL ON ONE SIDE HANDRAIL NOTE: 1) LOCATION AT 34-38 INCHES ABOVE THE STAIR NOSING. 2) GRASP DIMENSION BETWEEN 1-1/4-2 INCHES. 3) PROVIDE CONTINUOUS HANDRAIL OR TERMINATE AT NEWEL POSTS OR SAFETY TERMINAL. * NOTES: R314.2.3 A HEAT DETECTOR OR HEAT ALARM RATED FOR THE AMBIENT OUTDOOR TEMPERATURES AND HUMIDITY SHALL BE INSTALLED IN NEW GARAGES THAT ARE ATTACHED TO OR LOCATED UNDER NEW AND EXISTING DWELLINGS. HEAT DETECTORS AND HEAT ALARMS SHALL BE INSTALLED IN A CENTRAL LOCATION AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. DocuSign Envelope ID: BE699953-BA0C-4D42-93F9-BAF4560A83BC