Loading...
HomeMy WebLinkAboutRC 20211222000330 iI Return Address: jflj 1111111111111II III11111111I I1II1 U11 City Clerk's Office 20211222000330 City of Renton COVENANT Rec:$220.50 1055 S GradyWay12122/2021 9:47 AM KING COUNTY,WA Renton,WA 98057 DECLARATION OF COVENANT FOR INSPECTION AND MAINTENANCE OF DRAINAGE FACILITIES AND ON-SITE BMPS Grantor: Dalpay Properties LLC Grantee: City of Renton, a Washington municipal corporation Legal Description: LOT 5, Renton short plat No. LUA-03-125, recorded under recording No. 20050927900007, Records of King.County, Washington. Assessor's Tax Parcel ID#: 042305-9032 IN CONSIDERATION of the approved City of Renton (check one of the following) ❑ Residential Building Permit ['Commercial Building Permit ['Clearing and Grading Permit ❑✓ Civil Construction or Utility Permit for Permit(s)C19005091 (Construction/Building/Utility Permit#)relating to the real property ("Property") described above, the Grantor(s), the owner(s) in fee of that Property, hereby covenants (covenant)with the City of Renton ("City of Renton" or"City"), a municipal corporation of the state of Washington,that he/she(they)will observe,consent to,and abide by the conditions and obligations set forth and described in Paragraphs 1 through 9 below with regard to the Property, and hereby grants (grant) an easement as described in Paragraphs 2 and 3. Grantor(s) hereby grants(grant),covenants (covenant),and agrees (agree) as follows: 1. The Grantor(s)or his/her(their)successors in interest and assigns("Owners")shall at their own cost,operate, maintain, and keep in good repair,the Property's drainage facilities constructed as required in the approved construction plans and specifications R-4097 (Project Plan#) on file with the City of Renton and submitted to the City of Renton for the review and approval of permit(s) C19005091 (Construction/Building/Utility Permit#).The Property's drainage facilities are shown and/or listed on Exhibit A—Site Plan. The Property's drainage facilities shall be maintained in compliance with the operation and maintenance schedule included and attached herein as Exhibit B—Operations and Maintenance. Drainage facilities include pipes, channels, flow control facilities, water quality facilities, on-site best management practices (BMPs) and other engineered structures designed to manage and/or Page 1 of 18 • treat stormwater on the Property. On-site BMPs include dispersion and infiltration devices, bioretention, permeable pavements, rainwater harvesting systems, tree retention credit, reduced impervious surface footprint,vegetated roofs and other measures designed to mimic pre-developed hydrology and minimize stormwater runoff on the Property. 2. City of Renton shall have the right to ingress and egress over those portions of the Property necessary to perform inspections of the stormwater facilities and BMPs and conduct maintenance activities specified in this Declaration of Covenant and in accordance with the Renton Municipal Code. City of Renton shall provide at least thirty(30) days'written notice to the Owners that entry on the Property is planned for the inspection of drainage facilities.After the thirty(30) days,the Owners shall allow the City of Renton to enter for the sole purpose of inspecting drainage facilities. In lieu of inspection by the City,the Owners may elect to engage a licensed civil engineer registered in the state of Washington who has expertise in drainage to inspect the drainage facilities and provide a written report describing their condition. If the engineer option is chosen,the Owners shall provide written notice to the City of Renton within fifteen (15)days of receiving the City's notice of inspection.Within thirty(30)days of giving this notice,the Owners,or engineer on behalf of the Owners,shall provide the engineer's report to the City of Renton. If the report is not provided in a timely manner as specified above,the City of Renton may inspect the drainage facilities without further notice. 3. If City of Renton determines from its inspection, or from an engineer's report provided in accordance with Paragraph 2,that maintenance, repair, restoration, and/or mitigation work is required to be done to any of the drainage facilities, City of Renton shall notify the Owners of the specific maintenance, repair, restoration, and/or mitigation work ("Work") required pursuant to the Renton Municipal Code. The City shall also set a reasonable deadline for the Owners to complete the Work, or to provide an engineer's report that verifies completion of the Work. After the deadline has passed, the Owners shall allow the City access to re-inspect the drainage facilities unless an engineer's report has been provided verifying completion of the Work. If the Work is not completed within the time frame set by the City, the City may initiate an enforcement action and/or perform the Work and hereby is given access to the Property for such purposes. Written notice will be sent to the Owners stating the City's intention to perform such Work.This Work will not commence until at least seven(7)days after such notice is mailed. If, within the sole discretion of the City, there exists an imminent or present danger, the seven (7) day notice period will be waived and Work will begin immediately. 4. The Owners shall assume all responsibility for the cost of any Work, or any measures taken by the City to address conditions as described in Paragraph 3. Such responsibility shall include reimbursement to the City within thirty(30)days of the receipt of the invoice for any such Work performed. Overdue payments will require payment of interest at the maximum legal rate allowed by RCW 19.52.020(currently twelve percent(12%)). If the City initiates legal action to enforce this agreement, the prevailing party in such action is entitled to recover reasonable litigation costs and attorney's fees. 5. The Owners are required to obtain written approval from City of Renton prior to filling, piping, cutting, or removing vegetation (except in routine landscape maintenance) in open vegetated stormwater facilities (such as swales, channels, ditches, ponds, etc.), or performing any alterations or modifications to the drainage facilities referenced in this Declaration of Covenant. Page 2 of 18 6. Any notice or consent required to be given or otherwise provided for by the provisions of this Agreement shall be effective upon personal delivery,or three(3)days after mailing by Certified Mail, return receipt requested. 7. With regard to the matters addressed herein,this agreement constitutes the entire agreement between the parties, and supersedes all prior discussions, negotiations, and all agreements whatsoever whether oral or written. 8. This Declaration of Covenant is intended to protect the value and desirability and promote efficient and effective management of surface water drainage of the real property described above, and shall inure to the benefit of all the citizens of the City of Renton and its successors and assigns. This Declaration of Covenant shall run with the land and be binding upon Grantor(s), and Grantor's(s')successors in interest,and assigns. 9. This Declaration of Covenant may be terminated by execution of a written agreement by the Owners and the City that is recorded by King County in its real property records. IN WITNESS WHEREOF, this Declaration of Covenant for the Inspection and Maintenance of Drainage Facilities is executed this 30 day of /Vv v , 20 2-/ A R,owner of erty GRANTOR,owner of the Property STATE OF WASHINGTON ) COUNTY OF KING )ss. On this day personally appeared before me: -5600"e,S VJ. 1)0 P0., , to me known to be the individual(s) described in and who executed the within and foregoing instrument and acknowledged that they signed the same as their free and voluntary act and deed,for the uses and purposes therein stated. Given under my hand and official seal this 30t day of NOJ£"V e-r 20 Z G F01 ii,� ,0 TA'►a 0 i Printed name 18sl07i '"s Notary Public in and for the State of S ;%h &Bo— =O Washington, residing at '. Q?.1116. Gk -Ck5.2...3,0o6C \ lid ' WASH\ �`‘`� v �,} �111��‘���\‘\,` My appointment expires I Z' — Z I Page 3 of 18 APN — APN . - APN 042305-9387 042305-9382 1 I 042305-9116 I SANG SING ONG , h. �I PAUL RI NGUYEN w S88'14'39"E 'r :8'14,�38.73 BARFKNECHT J ?IF, 106 4f 'r LI 65.65' APN Ki N / in I o — -042305-9388 ,n � — — MANH DO o , o in APN Z. _ .9 1 M042305-92 31 — - I' o SANSERN N PRoMP1BALCHEEP 1 APN n2 042305-9408 o �' I y v^�o MICHAEL FLORIAN .1• i u r` f o`er =M APN I M r35y1y. M 042305-9409 m 1 �n oo�' c� o MATTHEW 0 w j �, N BIELER C m w "A• �/ •APN Ov ' o / _ 042305-9410 2 WENDELL wI 1 DEVERA :, I a S26'24'23"W APN ci ite-,.5, ' 042305 66.01' ws�\r' -TR 'A f �, ,5588;56 17" N N Z o o, II \\ ;t 0.01 • I o -� APN 4). G-' /// ,I..' . 75.00.I��-�`�'-, - I ci 042305-TRCT oc // 1 1 I "8' 6 7 74' -- • - AD 11 II 11 I 3 DETENTION POND ��� °'• o N APN w rn 0 r." 042305-9411 vi o ^ TUAN I o NGUYEN I c r'i /�. co — 97.33' 7�.0,1 � j N88'09'53"W N88'09 53"W APN 259985-0000 c d c oo ar NOTE D 0 o fi-80, WAAREA NOT INCLUDED FOR INSPECTIONS N- O_. Job Number DC Scale: For Des'9"Qd — Horizontal 1"=80' Vertical N/A 17884 Dmrn DC DALPAY SHORT PLAT BARGHAUSEN Sheet Checked DD CONSULTING ENGINEERS, INC' Title: EXHIBIT "A" Approved DD 18215 72ND AVENUE SOUTH STORM DRAINAGE KENT, WA 98032 1 of 1 m; 11/2/21 425.251.6222 BARGHAUSEN.COM FACILITIES • EXHIBIT B - OPERATIONS AND MAINTENANCE NO 1 DETENTION PONDS Maintenance Defect or Problem Conditions When Maintenance Is Needed Results Expected When Component Maintenance Is Performed Site Trash and debris Any trash and debris which exceed 1 cubic foot Trash and debris cleared from site. per 1,000 square feet(this is about equal to the amount of trash it would take to fill up one standard size office garbage can). In general, there should be no visual evidence of dumping. Noxious weeds Any noxious or nuisance vegetation which may Noxious and nuisance vegetation constitute a hazard to County personnel or the removed according to applicable public. regulations. No danger of noxious vegetation where County personnel or the public might normally be. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Grass/groundcover Grass or groundcover exceeds 18 inches in Grass or groundcover mowed to a height. height no greater than 6 inches. Top or Side Slopes Rodent holes Any evidence of rodent holes if facility is acting Rodents removed or destroyed and of Dam,Berm or as a dam or berm,or any evidence of water dam or berm repaired. Embankment piping through dam or berm via rodent holes. Tree growth Tree growth threatens integrity of slopes,does Trees do not hinder facility not allow maintenance access,or interferes with performance or maintenance maintenance activity. If trees are not a threat or activities. not interfering with access or maintenance,they do not need to be removed. Erosion Eroded damage over 2 inches deep where cause Slopes stabilized using appropriate of damage is still present or where there is erosion control measures. If erosion potential for continued erosion. Any erosion is occurring on compacted slope,a observed on a compacted slope. licensed civil engineer should be consulted to resolve source of erosion. Settlement Any part of a dam,berm or embankment that Top or side slope restored to design has settled 4 inches lower than the design dimensions. If settlement is elevation. significant,a licensed civil engineer should be consulted to determine the cause of the settlement. Storage Area Sediment Accumulated sediment that exceeds 10%of the Sediment cleaned out to designed accumulation designed pond depth. pond shape and depth;pond reseeded if necessary to control erosion. Liner damaged Liner is visible or pond does not hold water as Liner repaired or replaced. (If Applicable) designed. Inlet/Outlet Pipe. Sediment Sediment filling 20%or more of the pipe. Inlet/outlet pipes clear of sediment. accumulation Trash and debris Trash and debris accumulated in inlet/outlet No trash or debris in pipes. pipes(includes floatables and non-floatables). Damaged Cracks wider than'/z-inch at the joint of the No cracks more than'A-inch wide at inlet/outlet pipes or any evidence of soil entering the joint of the inlet/outlet pipe. at the joints of the inlet/outlet pipes. Emergency Tree growth Tree growth impedes flow or threatens stability of Trees removed. Overflow/Spillway spillway. Rock missing Only one layer of rock exists above native soil in Spillway restored to design area five square feet or larger or any exposure of standards. native soil on the spillway. 4/24/2016 2016 Surface Water Design Manual—Appendix A 5 of 18 APPENDIX A MAINTENANCE REQUIREMENTS.FOR FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO,4 CONTROL STRUCTUREIFLOW RESTRICTOR Maintenance Defect or Problem Condition When Maintenance is Needed Results Expected When Component Maintenance is Performed Structure Trash and debris Trash or debris of more than'A cubic foot which No Trash or debris blocking or is located Immediately in front of the structure potentially blocking entrance to opening or is blocking capacity of the structure structure. by more than 10%. Trash or debris in the structure that exceeds 1/3 No trash or debris in the structure. the depth from the bottom of basin to invert the lowest pipe into or out of the basin. Deposits of garbage exceeding 1 cubic foot in No condition present which would volume. attract or support the breeding of insects or rodents. Sediment Sediment exceeds 60%of the depth from the Sump of structure contains no bottom of the structure to the invert of the lowest sediment. pipe into or out of the structure or the bottom of the FROP-T section or is within 6 inches of the invert of the lowest pipe into or out of the structure or the bottom of the FROP-T section. Damage to frame Corner of frame extends more than%inch past Frame is even with curb. and/or top slab curb face into the street(If applicable). Top slab has holes larger than 2 square inches Top slab is free of holes and cracks. or cracks wider than inch. Frame not sitting flush on top slab,i.e., Frame is sitting flush on top slab. separation of more than'/.inch of the frame from the top slab. Cracks in walls or Cracks wider than'A inch and longer than 3 feet, Structure is sealed and structurally bottom any evidence of soil particles entering structure sound. through cracks,or maintenance person judges that structure is unsound. Cracks wider than inch and longer than 1 foot No cracks more than 1/4 inch wide at at the joint of any inlet/outlet pipe or any the joint of inlet/outlet pipe. evidence of soil particles entering structure through cracks. Settlement/ Structure has settled more than 1 inch or has Basin replaced or repaired to design misalignment rotated more than 2 inches out of alignment. standards. Damaged pipe joints Cracks wider than'/-inch at the joint of the No cracks more than'/-inch wide at inlet/outlet pipes or any evidence of soil entering the joint of inlet/outlet pipes. the structure at the joint of the inlet/outlet pipes. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Ladder rungs missing Ladder is unsafe due to missing rungs, Ladder meets design standards and or unsafe misalignment,rust,cracks,or sharp edges. allows maintenance person safe access. FROP-T Section Damage T section is not securely attached to structure T section securely attached to wall wall and outlet pipe structure should support at and outlet pipe. least 1,000 lbs of up or down pressure. Structure is not in upright position(allow up to Structure in correct position. 10%from plumb). Connections to outlet pipe are not watertight or Connections to outlet pipe are water show signs of deteriorated grout. tight;structure repaired or replaced and works as designed. Any holes—other than designed holes—in the Structure has no holes other than structure. designed holes. 2016 Surface Water Design Manual—Appendix A 4/24/2016 6 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 4 CONTROL STRUCTURE/FLOW RESTRICTOR Maintenance Defect or Problem Condition When Maintenance is Needed Results Expected When Component Maintenance is Performed Cleanout Gate Damaged or missing Cleanout gate is missing. Replace cleanout gate. Cleanout gate is not watertight. Gate is watertight and works as designed. Gate cannot be moved up and down by one Gate moves up and down easily and maintenance person. is watertight. Chain/rod leading to gate is missing or damaged. Chain is in place and works as designed. Orifice Plate Damaged or missing Control device is not working properly due to Plate is in place and works as missing,out of place,or bent orifice plate. designed. Obstructions Any trash,debris,sediment,or vegetation Plate is free of all obstructions and blocking the plate. works as designed. Overflow Pipe Obstructions Any trash or debris blocking(or having the. Pipe is free of all obstructions and potential of blocking)the overflow pipe. works as designed. Deformed or Lip of overflow pipe is bent or deformed. Overflow pipe does not allow damaged lip overflow at an elevation lower than design Inlet/Outlet Pipe Sediment Sediment filling 20%or more of the pipe. ,Inlet/outlet pipes clear of sediment. accumulation Trash and debris Trash and debris accumulated in inlet/outlet No trash or debris in pipes. pipes(includes floatables and non-floatables). Damaged Cracks wider than'/2-inch at the joint of the No cracks more than'h-inch wide at inlet/outlet pipes or any evidence of soil entering the joint of the inlet/outlet pipe. at the joints of the inlet/outlet pipes. Metal Grates Unsafe grate opening Grate with opening wider than 7/8 inch. Grate opening meets design (If Applicable) standards. Trash and debris Trash and debris that is blocking more than 20% Grate free of trash and debris. of grate surface. footnote to guidelines for disposal Damaged or missing Grate missing or broken member(s)of the grate. Grate is in place and meets design standards. Manhole Cover/Lid Cover/lid not in place Cover/lid is missing or only partially in place. Cover/lid protects opening to Any open structure requires urgent structure. maintenance. Locking mechanism Mechanism cannot be opened by one Mechanism opens with proper tools. Not Working maintenance person with proper tools.Bolts cannot be seated. Self-locking cover/lid does not work. Cover/lid difficult to One maintenance person cannot remove Cover/lid can be removed and Remove cover/lid after applying 80 lbs.of lift. reinstalled by one maintenance person. 4/24/20I 6 2016 Surface Water Design Manual--Appendix A 7 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FOR FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 5 CATGH BASINS AND MANHOLES Maintenance Defect or Problem Condition When Maintenance is Needed Results Expected When Component Maintenance is Performed Structure Sediment Sediment exceeds 60%of the depth from the Sump of catch basin contains no bottom of the catch basin to the invert of the sediment. lowest pipe into or out of the catch basin or is within 6 inches of the invert of the lowest pipe into or out of the catch basin. Trash and debris Trash or debris of more than cubic foot which No Trash or debris blocking or is located immediately in front of the catch basin potentially blocking entrance to opening or is blocking capacity of the catch basin catch basin. by more than 10%. Trash or debris in the catch basin that exceeds No trash or debris in the catch 1/3 the depth from the bottom of basin to invert basin. the lowest pipe into or out of the basin. Dead animals or vegetation that could generate No dead animals or vegetation odors that could cause complaints or dangerous present within catch basin. gases(e.g.,methane). Deposits of garbage exceeding 1 cubic foot in No condition present which would volume. attract or support the breeding of insects or rodents. Damage to frame Corner of frame extends more than%inch past Frame is even with curb. and/or top slab curb face into the street(If applicable). Top slab has holes larger than 2 square inches Top slab is free of holes and cracks. or cracks wider than'/<inch. Frame not sitting flush on top slab,i.e., Frame is sitting flush on top slab. separation of more than%inch of the frame from the top slab. Cracks in walls or Cracks wider than' inch and longer than 3 feet, Catch basin is sealed and is bottom any evidence of soil particles entering catch structurally sound. basin through cracks,or maintenance person judges that catch basin is unsound. Cracks wider than inch and longer than 1 foot No cracks more than inch wide at at the joint of any inlet/outlet pipe or any the joint of inlet/outlet pipe. evidence of soil particles entering catch basin through cracks. Settlement/ Catch basin has settled more than 1 inch or has Basin replaced or repaired to design misalignment rotated more than 2 inches out of alignment. standards. Damaged pipe joints Cracks wider than%-inch at the joint of the No cracks more than'%-inch wide at inlet/outlet pipes or any evidence of soil entering the joint of inlet/outlet pipes. the catch basin at the joint of the inlet/outlet pipes. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants. present other than a surface oil film. Inlet/Outlet Pipe Sediment Sediment filling 20%or more of the pipe. Inlet/outlet pipes clear of sediment. accumulation Trash and debris Trash and debris accumulated in inlet/outlet No trash or debris in pipes. pipes(includes floatables and non-floatables). Damaged Cracks wider than at the joint of the No cracks more than' -inch wide at inlet/outlet pipes or any evidence of soil entering the joint of the inlet/outlet pipe. at the joints of the inlet/outlet pipes. 2016 Surface Water Design Manual—Appendix A 4/24/2016 8 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 5-CATCH BASINS AN©MANHOLES Maintenance Defect or Problem Condition When Maintenance is Needed Results Expected When Component Maintenance is Performed Metal Grates Unsafe grate opening Grate with opening wider than 7Is inch. Grate opening meets design (Catch Basins) standards. Trash and debris Trash and debris that is blocking more than 20% Grate free of trash and debris. of grate surface. footnote to guidelines for disposal Damaged or missing . Grate missing or broken member(s)of the grate. Grate is in place and meets design Any open structure requires urgent standards. maintenance. Manhole Cover/Lid Coverllid not in place Cover/lid is missing or only partially in place. Cover/lid protects opening to Any open structure requires urgent structure. maintenance. Locking mechanism Mechanism cannot be opened by one Mechanism opens with proper tools. Not Working maintenance person with proper tools.Bolts cannot be seated. Self-locking cover/lid does not work. Cover/lid difficult to One maintenance person cannot remove Cover/lid can be removed and Remove cover/lid after applying 80 lbs.of lift. reinstalled by one maintenance person. 4/24/2016 2016 Surface Water Design Manual—Appendix A 9 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FOR FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 6-y CONVEYANCE PIPES AND DITCHES Maintenance Defect or Problem Conditions When Maintenance is Needed Results Expected When Component Maintenance is Performed Pipes Sediment&debris Accumulated sediment or debris that exceeds Water flows freely through pipes. accumulation 20%of the diameter of the pipe. Vegetation/roots Vegetation/roots that reduce free movement of Water flows freely through pipes. water through pipes. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Damage to protective Protective coating is damaged;rust or corrosion Pipe repaired or replaced. coating or corrosion is weakening the structural integrity of any part of pipe. Damaged Any dent that decreases the cross section area Pipe repaired or replaced. of pipe by more than 20%or is determined to have weakened structural integrity of the pipe. Ditches Trash and debris Trash and debris exceeds 1 cubic foot per 1,000 Trash and debris cleared from square feet of ditch and slopes. ditches. Sediment Accumulated sediment that exceeds 20%of the Ditch cleaned/flushed of all accumulation design depth. sediment and debris so that it matches design. Noxious weeds Any noxious or nuisance vegetation which may Noxious and nuisance vegetation constitute a hazard to County personnel or the removed according to applicable public. regulations. No danger of noxious vegetation where County personnel or the public might normally be. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of ` pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Vegetation Vegetation that reduces free movement of water Water flows freely through ditches. through ditches. Erosion damage to Any erosion observed on a ditch slope. Slopes are not eroding. slopes Rock lining out of One layer or less of rock exists above native soil Replace rocks to design standards. place or missing(If area 5 square feet or more,any exposed native Applicable) soil. 2016 Surface Water Design Manual—Appendix A 4/24/2016 10of18 APPENDIX A MAINTENANCE REQUIREMENTS FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 7 DEBRIS BARRIERS(E.G.,TRASH RACKS) Maintenance Defect or Problem Condition When Maintenance is Needed Results Expected When Component Maintenance is Performed. Site Trash and debris Trash or debris plugging more than 20%of the Barrier clear to receive capacity area of the barrier. flow. Sediment Sediment accumulation of greater than 20%of Barrier clear to receive capacity accumulation the area of the barrier flow. Structure Cracked broken or Structure which bars attached to is damaged- Structure barrier attached to is loose pipe is loose or cracked or concrete structure is sound. cracked,broken of loose. Bars Bar spacing Bar spacing exceeds 6 inches. Bars have at most 6 inches spacing. Damaged or missing Bars are bent out of shape more than 3 inches. Bars in place with no bends more bars than'A inch. Bars are missing or entire barrier missing. Bars in place according to design. Bars are loose and rust is causing 50% Repair or replace barrier to design deterioration to any part of barrier. standards. 4/24/20I6 2016 Surface Water Design Manual—Appendix A 11 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FOR FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NOS 8 ENERGY DISSIPATERS Maintenance Defect or Problem Conditions When Maintenance is Needed Results Expected When Component Maintenance is Performed. Site Trash and debris Trash and/or debris accumulation. Dissipater clear of trash and/or debris. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Rock Pad Missing or moved Only one layer of rock exists above native soil in Rock pad prevents erosion. Rock area five square feet or larger or any exposure of native soil. Dispersion Trench Pipe plugged with Accumulated sediment that exceeds 20%of the Pipe cleaned/flushed so that it sediment design depth. matches design. Not discharging water Visual evidence of water discharging at Water discharges from feature by , properly concentrated points along trench(normal sheet flow. condition is a"sheet flow"of water along trench). Perforations plugged. Over 1/4 of perforations in pipe are plugged with Perforations freely discharge flow. debris or sediment. Water flows out top of Water flows out of distributor catch basin during No flow discharges from distributor "distributor"catch any storm less than the design storm. catch basin. basin. Receiving area over- Water in receiving area is causing or has No danger of landslides. saturated potential of causing landslide problems. Gabions Damaged mesh Mesh of gabion broken,twisted or deformed so Mesh is intact,no rock missing. structure is weakened or rock may fall out. Corrosion Gabion mesh shows corrosion through more All gabion mesh capable of than'/.of its gage. containing rock and retaining designed form. Collapsed or Gabion basket shape deformed due to any All gabion baskets intact,structure deformed baskets cause. stands as designed. Missing rock Any rock missing that could cause gabion to No rock missing. loose structural integrity. Manhole/Chamber Worn or damaged Structure dissipating flow deteriorates to'/:or Structure is in no danger of failing. post,baffles or side of original size or any concentrated worn spot chamber exceeding one square foot which would make structure unsound. Damage to wall, Cracks wider than'/z-inch or any evidence of soil Manhole/chamber is sealed and entering the structure through cracks,or structurallysound. frame,bottom,and/or maintenance inspection personnel determines top slab that the structure is not structurally sound. Damaged pipe joints Cracks wider than 1/2-inch at the joint of the No soil or water enters and no water inlet/outlet pipes or any evidence of soil entering discharges at the joint of inlet/outlet the structure at the joint of the inlet/outlet pipes. pipes. 2016 Surface Water Design Manual—Appendix A 4/24/2016 12 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NOS 9 FENCING Maintenance Defect or Problem Conditions When Maintenance is Needed Results Expected When Component Maintenance is Performed Site Erosion or holes Erosion or holes more than 4 inches high and 12- No access under the fence. under fence 18 inches wide permitting access through an opening under a fence. Wood Posts,Boards Missing or damaged Missing or broken boards,post out of plumb by No gaps on fence due to missing or and Cross Members parts more than 6 inches or cross members broken broken boards,post plumb to within 1'/z inches,cross members sound. Weakened by rotting Any part showing structural deterioration due to All parts of fence are structurally or Insects rotting or insect damage sound. Damaged or failed Concrete or metal attachments deteriorated or Post foundation capable of post foundation unable to support posts. supporting posts even in strong wind. Metal Posts,Rails Damaged parts Post out of plumb more than 6 inches. Post plumb to within 1%inches. and Fabric Top rails bent more than 6 inches. Top rail free of bends greater than 1 inch. Any part of fence(including post,top rails,and Fence is aligned and meets design fabric)more than 1 foot out of design alignment. standards. Missing or loose tension wire. Tension wire in place and holding fabric. Deteriorated paint or Part or parts that have a rusting or scaling Structurally adequate posts or parts protective coating condition that has affected structural adequacy. with a uniform protective coating. Openings in fabric Openings in fabric are such that an 8-inch - Fabric mesh openings within 50%of diameter ball could fit through. grid size. 4/24/2016 2016 Surface Water Design Manual—Appendix A 13 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FOR FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NQ 10 GATES/S®LLARDS/ACCESS BARRIERS Maintenance Defect or Problem Conditions When Maintenance is Needed Results Expected When Component Maintenance is Performed Chain Link Fencing Damaged or missing Missing gate. Gates in place. Gate, members Broken or missing hinges such that gate cannot Hinges intact and lubed.Gate is be easily opened and closed by a maintenance working freely. person. Gate is out of plumb more than 6 inches and Gate is aligned and vertical. more than 1 foot out of design alignment. Missing stretcher bar,stretcher bands,and ties. Stretcher bar,bands,and ties in place. Locking mechanism Locking device missing,no-functioning or does Locking mechanism prevents does not lock gate not link to all parts. opening of gate. Openings in fabric Openings in fabric are such that an 8-inch Fabric mesh openings within 50%of diameter ball could fit through. grid size. Bar Gate Damaged or missing Cross bar does not swing open or closed,is Cross bar swings fully open and cross bar missing or is bent to where it does not prevent closed and prevents vehicle access. vehicle access. Locking mechanism Locking device missing,no-functioning or does Locking mechanism prevents does not lock gate not link to all parts. opening of gate. Support post Support post does not hold cross bar up. Cross bar held up preventing vehicle damaged access into facility. Bollards Damaged or missing Bollard broken,missing,does not fit into support No access for motorized vehicles to hole or hinge broken or missing. get into facility. Does not lock Locking assembly or lock missing or cannot be No access for motorized vehicles to attached to lock bollard in place. get into facility. Boulders Dislodged Boulders not located to prevent motorized No access for motorized vehicles to vehicle access. get into facility. Circumvented Motorized vehicles going around or between No access for motorized vehicles to boulders. get into facility. 2016 Surface Water Design Manual—Appendix A 4/24/2016 14 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 11- GROUNDS(LANDSCAPING) Maintenance Defect or Problem Conditions When Maintenance is Needed Results Expected When Component Maintenance is Performed Site Trash or litter Any trash and debris which exceed 1 cubic foot Trash and debris cleared from site. per 1,000 square feet(this is about equal to the amount of trash it would take to fill up one standard size office garbage can). In general, there should be no visual evidence of dumping. Noxious weeds Any noxious or nuisance vegetation which may Noxious and nuisance vegetation constitute a hazard to County personnel or the removed according to applicable public. regulations. No danger of noxious vegetation where County personnel or the public might normally be. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Grass/groundcover Grass or groundcover exceeds 18 inches in Grass or groundcover mowed to a height. height no greater than 6 inches. Trees and Shrubs Hazard Any tree or limb of a tree identified as having a No hazard trees in facility. potential to fall and cause property damage or threaten human life. A hazard tree identified by a qualified arborist must be removed as soon as possible. Damaged Limbs or parts of trees or shrubs that are split or Trees and shrubs with less than 5% broken which affect more,than 25%of the total of total foliage with split or broken foliage of the tree or shrub. limbs. Trees or shrubs that have been blown down or No blown down vegetation or knocked over. knocked over vegetation. Trees or shrubs free of injury. Trees or shrubs which are not adequately Tree or shrub in place and supported or are leaning over,causing exposure adequately supported;dead or of the roots. diseased trees removed. 4/24/2016 2016 Surface Water Design Manual—Appendix A 15 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FOR FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 1 Z , ACCESS ROADS Maintenance Defect or Problem Condition When Maintenance is Needed Results Expected When Component Maintenance is Performed Site Trash and debris Trash and debris exceeds 1 cubic foot per 1,000 Roadway drivable by maintenance square feet(i.e.,trash and debris would fill up vehicles. one standards size garbage can). Debris which could damage vehicle tires or Roadway drivable by maintenance prohibit use of road. vehicles. Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Blocked roadway Any obstruction which reduces clearance above Roadway overhead clear to 14 feet road surface to less than 14 feet. high. Any obstruction restricting the access to a 10-to At least 12-foot of width on access 12 foot width for a distance of more than 12 feet road. or any point restricting access to less than a 10 foot width. Road Surface Erosion,settlement, Any surface defect which hinders or prevents Road drivable by maintenance potholes,soft spots, maintenance access. vehicles. ruts Vegetation on road Trees or other vegetation prevent access to Maintenance vehicles can access surface facility by maintenance vehicles. facility. Shoulders and Erosion Erosion within 1 foot of the roadway more than 8 Shoulder free of erosion and Ditches inches wide and 6 inches deep. matching the surrounding road. Weeds and brush Weeds and brush exceed 18 inches in height or Weeds and brush cut to 2 inches in hinder maintenance access. height or cleared in such a way as to allow maintenance access. Modular Grid Contaminants and Any evidence of contaminants or pollution such Materials removed and disposed of Pavement pollution as oil,gasoline,concrete slurries or paint. according to applicable regulations. Source control BMPs implemented if appropriate. No contaminants present other than a surface oil film. Damaged or missing Access surface compacted because of broken Access road surface restored so on missing modular block. road infiltrates. • 2016 Surface Water Design Manual—Appendix A 4/24/2016 16 of 18 APPENDIX A MAINTENANCE REQUIREMENTS FLOW CONTROL,CONVEYANCE,AND WQ FACILITIES NO 22 'BAFFLE OILMIATER SEPARAT`Oh Maintenance Defect Condition When Maintenance is Needed Results Expected When Component Maintenance is Performed Site Trash and debris Any trash or debris which impairs the function of Trash and debris removed from the facility. • facility. Contaminants and Floating oil in excess of 1 inch in first chamber, No contaminants present other than pollution any oil in other chambers or other contaminants a surface oil film. of any type in any chamber. Vault Treatment Sediment Sediment accumulates exceeds 6 inches in the No sediment in the vault. Area accumulation vault. Discharge water not Inspection of discharge water shows obvious Effluent discharge is clear. clear signs of poor water quality-effluent discharge from vault shows thick visible sheen. Trash or debris Any trash and debris accumulation in vault Vault is clear of trash and debris. accumulation (floatables and non-floatables). Oil accumulation Oil accumulations that exceed 1 inch,at the No visible oil depth on water. surface of the water in the oil/water separator chamber. Vault Structure Damage to Wall, Cracks wider than%-inch or evidence of soil Vault replaced or repaired to design Frame,Bottom, particles entering the structure through the specifications. and/or Top Slab cracks,or maintenance/inspection personnel determines that the vault is not structurally sound. Baffles damaged Baffles corroding,cracking,warping and/or Repair or replace baffles to showing signs of failure as determined by specifications. maintenance inspection personnel. Gravity Drain Inoperable valve Valve will not open and close. Valve opens and closes normally. Valve won't seal Valve does not seal completely. Valve completely seals closed. Inlet/Outlet Pipe Sediment Sediment filling 20%or more of the pipe. Inlet/outlet pipes clear of sediment. accumulation Trash.and debris Trash and debris accumulated in inlet/outlet No trash or debris in pipes. pipes(includes floatables and non-floatables). Damaged Cracks wider than 1%-inch.at the joint of the No cracks more than%-inch wide at inlet/outlet pipes or any evidence of soil entering the joint of the inlet/outlet pipe. at the joints of the inlet/outlet pipes. Access Manhole Cover/lid not in place Cover/lid is missing or only partially in place. Manhole access covered. Any open manhole requires immediate maintenance. Locking mechanism Mechanism cannot be opened by one Mechanism opens with proper tools. not working maintenance person with proper tools.Bolts cannot be seated. Self-locking cover/lid does not work. Cover/lid difficult to One maintenance person cannot remove Cover/lid can be removed and remove cover/lid after applying 80 lbs of lift. reinstalled by one maintenance person. Ladder rungs unsafe Missing rungs,misalignment,rust,or cracks. Ladder meets design standards. Allows maintenance person safe access. Large access Damaged or difficult Large access doors or plates cannot be Replace or repair access door so it doors/plate to open opened/removed using normal equipment. can opened as designed. Gaps,doesn't cover Large access doors not flat and/or access Doors close flat and cover access completely opening not completely covered. opening completely. Lifting Rings missing, Lifting rings not capable of lifting weight of door Lifting rings sufficient to lift or rusted or cover/lid. remove cover/lid. 4/24/2016 2016 Surface Water Design Manual-Appendix A 17 of 18 4 EXHIBIT C LEGAL DESCRIPTION LOT 5, RENTON SHORT PLAT NO. LUA-03-125, RECORDED UNDER RECORDING NO. 20050927900007, RECORDS OF KING COUNTY, WASHINGTON. SITUATED IN THE COUNTY OF KING, STATE OF WASHINGTON. 17884L.001.docx 18 of 18