HomeMy WebLinkAboutP_Standard Details.pdfPRECAST BASE SECTION SEE NOTE 1 NOTES: 1.AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2.THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3.THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4.THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5.THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H:24V OR STEEPER. 6.THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7.ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON-SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8.ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. FRAME AND VANED GRATE RECTANGULAR ADJUSTMENT SECTION 34" 24" 30 20 5" 5" 1", 2", 4", 6", 12", OR 24" ONE #3BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15" CPSSP*, STD. SPEC. 9-05.20 12" SOLID WALL PVC, STD. SPEC. 9-05.12(1)15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2)15" CORRUGATED POLYETHYLENE STORM SEWER PIPE 26", S E E N O T E 6 22SEE N OTE 6 3"4"44"21" MIN.4" MI N. (T Y P.)3 BAR EACH SIDE 3 BAR EACH WAY 3 BAR EACH CORNER 3 BAR EACH CORNER 18" MIN.3 BAR HOOP ALTERNATIVE PRECAST BASE SECTION CATCH BASIN TYPE 1 STD. PLAN - 200. 00PUBLIC WORKS DEPARTMENT APPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/ NOTES: 1.NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2.THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3.THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4.KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5.ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7.MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8.FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9.ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 FLAT SLAB TOP SEE NOTE 6, TYP. REINFORCING STEEL, (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) INTEGRAL BASE PRECAST WITH RISER STEPS OR LADDER 4" MIN. 16" MAX.28" MAX. 48", 54", 60", 72", 84", 96", 120" OR 144" 12" (TYP.) 24" MIN.12" MAX. 1" MIN. 2.5" MAX. 12" 6" 15' MAX. FOR MAINTENANCE SEPARATE BASE PRECAST O" RING 12" 6" CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48"4"6"36"8" 54"4.5"8"42"8" 60"5"8"48"8" 72"6"8"60"12" 84"8"12"72"12" 96"8"12"84"12" 120"10"12"96"12" 144"12"12"108"12" PIPE ALLOWANCES CATCH BASIN DIAMETER PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER CONCRETE ALL METAL CPSSP 1 SOLID WALL PVC 2 PROFILE WALL PVC 3 48"24"30"24"30"30" 54"30"36"30"36"36" 60"36"42"36"42"42" 72"42"54"42"48"48" 84"54"60"54"48"48" 96"60"72"60"48"48" 120"66"84"60"48"48" 144"78"96"60"48"48" 1CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 2 STD. SPEC. 9-05.12(1) 3 STD. SPEC. 9-05.12(2) CATCH BASIN TYPE 2 STD. PLAN - 201.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT NOTES: ISOMETRIC SECTION B TOPFOUNDRY NAMEDIFLOW SECTION A 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3.FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. FLOWFLOWBOLT-DOWN SLOT DETAIL SEE NOTE 1 1/2" 3/4" 1 1/4" 5/8" BOLT-DOWN SLOT, SEE DETAIL AND NOTE 1 20" 5" 5" 5" 3" 1" 3" 5" 5" 5" DIRECTION OF FLOW 24" 7 OR 8 EQUAL SPACES 1 5/8" MAX. A BOUTFALL TO STREAM DUMP NO POLLUTANTS 3/8" RECESSED LETTERING RECTANGULAR VANED GRATE STD. PLAN - 204.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT ISOMETRIC NOTES: SECTION B TOPFOUNDRY NAMEDIFLOW SECTION A 1.BOLT-DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT-DOWN HOLES VARIES BY MANUFACTURER. 2.REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3.USE ONLY IN SAGS ON VERTICAL CURVES. 4.FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. FLOWFLOWBOLT-DOWN SLOT DETAIL SEE NOTE 1 1/2" 3/4" 1 1/4" 5/8" BOLT-DOWN SLOT, SEE DETAIL AND NOTE 1 20" 5" 5" 5" 3" 1" 3" 5" 5" 5" 24" 1 5/8" MAX. 4EQUAL SPACES 4 EQUAL SPACES A BOUTFALL TO STREAM DUMP NO POLLUTANTS 3/8" RECESSED LETTERING RECTANGULAR BI-DIRECTIONAL VANED GRATE STD. PLAN - 204.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT COVER SECTION VIEW ASTM A48 CL35B00371780MO/ DA/YR X3717C1PTEON BOLTING DETAIL GASKET GROOVE DETAIL FRAME SECTION VIEW COVER BOTTOM VIEW PLAN VIEW DRAINIFCOMADEINUSA EJIWDUMPNOPOLLU T AN T S - DRAINS T O S T REAMR E N T O N NOTES:1.ALL COVERS SHALL BE LOCKING LID PER EJ No. 3717C1 OR APPROVED EQUAL.1/2" LETTERING BOLT HOLES - 3 PLACES EQUALLY SPACED120° APART ON 23 1/16" DIA. B. C.1 1/4" LETTERING 1) 1" DIA. PICKHOLE 25" DIA.3/ 4"1"2 1/ 2"8 3/4"TYP.) 3) BLT SOC. (ALLEN HEAD)5/8"-11 x 1.5 SS RUBBER WASHER 5/ 8"25 1/4" DIA.26 1/2" DIA.23 3/8" DIA. CL OPEN 27 5/16" DIA.34 1/ 8" DIA.1 1/16"6"1/8" 1/4" 1 1/16"R1/8" 1/4" DIA. NEOPRENE GASKET STORM ROUND FRAME AND COVER PUBLIC)STD. PLAN - 204. 50PUBLIC WORKS DEPARTMENT APPROVED: DATEMartinPastucha Public WorksAdministratorUNLESSOTHERWISENOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/ 5" ECCENTRIC CONE SECTION 72" FLAT SLAB TOP RECTANGULAR ADJUSTMENT SECTION CIRCULAR ADJUSTMENT SECTION PREFABRICATED LADDER STEP 84" or 96" FLAT SLAB TOP NOTES: 1.AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED FOR ADJUSTMENT SECTIONS. 48", 54", or 60" FLAT SLAB TOP 20"x24", 24" DIA., 48" DIA., OR 54" DIA. HOLE 6 BARS @ 7" SPACING 12" 2" (TYP.) 1" MIN. 2 1/2" MAX. 12" (TYP.) 12" 9" 6" 48" MAX. 24" MIN. 5BARS @ 6" SPACING 20"x24", 24" DIA., 48" DIA., OR 54" DIA. HOLE 8" 2" (TYP.) 1" MIN. 2 1/2" MAX. TYPICAL ORIENTATION FOR ACCESS AND STEPS 6" 9 1/2" MAX. 12" MIN. 48" MIN. 24" MIN. 18" MIN. 42" MAX. 4 BARS @ 6" SPACING 20"x24" OR 24" DIA. HOLE 8" 2" (TYP.) 1" MIN. 2 1/2" MAX. 34" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 34" 24" 30 20 5" 5" 1", 2", 4", 6", 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 1", 2", 4", 6", 12", OR 24" MISCELLANEOUS DETAILS FOR DRAINAGE STRUCTURES STD. PLAN - 204.60 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 9 1 3 1 CROSS SECTION 4' MIN. NOTES: OVERFLOW SPILLWAY 6' MIN. WIDTH 24" SETTLING DEPTH & 12" DEPTH OF 2"-4" ROCK, 12" DEPTH OF 3/4"-1 1/2" WASHED GRAVEL. 18" SEDIMENT STORAGE 12" DEPTH 2" - 4" ROCK 12" DEPTH 3/4" - 1 1/2" WASHED GRAVEL FILTER FABRIC FENCING 24" MIN. SETTLING DEPTH 1.5' MIN. SEDIMENT STORAGE 3.5' - 5'5' MAX. 12" OVERFLOW DEPTH OUTFLOW CHANNEL IF CONSTRUCTED BY EXCAVATION 1.MAY BE CONSTRUCTED BY EXCAVATION OR BY BUILDING A BERM SEDIMENT TRAP STD. PLAN - 211.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.TO ESTABLISH CLEARING LIMITS, STAKE AND WIRE FENCE MAY BE USED: 1.1.1.AT THE BOUNDARY OF CRITICAL AREAS, THEIR BUFFERS AND OTHER AREAS REQUIRED TO BE LEFT UNCLEARED. 1.1.2.AS NECESSARY TO CONTROL VEHICLE ACCESS TO AND ON THE SITE. 2.MAINTENANCE AND REQUIREMENTS 2.1.IF THE FENCE IS DAMAGED OR VISIBILITY REDUCED, IT SHALL BE REPAIRED OR REPLACED IMMEDIATELY AND VISIBILITY RESTORED. 2.2.DISTURBANCE OF A CRITICAL AREA, CRITICAL BUFFER AREA, NATIVE GROWTH RETENTION AREA, OR OTHER AREA REQUIRED TO BE LEFT UNDISTURBED SHALL BE REPORTED TO THE CITY OF RENTON FOR RESOLUTION. 2.3.THE CITY MAY REQUIRE MORE SUBSTANTIAL FENCING IF THE FENCE DOES NOT PREVENT ENCROACHMENT INTO THOSE AREAS THAT ARE NOT TO BE DISTURBED. NOTES SURVEYFLAGGINGBAILINGWIRE DO NOT NAIL OR STAPLE WIRE TO TREES METAL FENCE POST (TYP.)3' MIN. 10' - 20' 12" MIN. STAKE AND WIRE FENCE STD. PLAN - 212.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 3 1 MAX. TRACKING" WITH MACHINERY UP AND DOWN THE SLOPE PROVIDES GROOVES THAT WILL CATCH SEED, RAINFALL AND REDUCE RUNOFF. TRACKING 1.CONDITIONS OF USE 1.1.ALL SLOPES STEEPER THAN 3H:1V AND GREATER THAN 5 VERTICAL FEET REQUIRE SURFACE ROUGHENING TO A DEPTH OF 2 TO 4 INCHES PRIOR TO SEEDING. 1.2.AREAS THAT WILL NOT BE STABILIZED IMMEDIATELY MAY BE ROUGHENED TO REDUCE RUNOFF VELOCITY UNTIL SEEDING TAKES PLACE. 1.3.SLOPES WITH A STABLE ROCK FACE DO NOT REQUIRE ROUGHENING. 1.4.SLOPES WHERE MOWING IS PLANNED SHOULD NOT BE EXCESSIVELY ROUGHENED. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.DISTURBED AREAS THAT WILL NOT REQUIRE MOWING MAY BE STAIR-STEP GRADED, GROOVED, OR LEFT ROUGH AFTER FILLING. 2.2.STAIR STEP GRADING IS PARTICULARLY APPROPRIATE IN SOILS CONTAINING LARGE AMOUNTS OF SOFT ROCK. STAIR SHOULD BE WIDE ENOUGH TO WORK WITH STANDARD EARTH MOVING EQUIPMENT. STAIRS STEPS MUST BE ON CONTOURS OR GULLIES WILL FORM ON THE SLOPE. 2.3.AREAS THAT WILL BE MOWED, MAY HAVE SMALL FURROWS LEFT BY DISKING, HARROWING, RAKING, OR SEED-PLANTING MACHINERY OPERATED ON THE CONTOUR. 2.4.GRADED AREAS WITH SLOPES GREATER THAN 3H:1V BUT LESS THAN 2H:1V SHOULD BE ROUGHENED BEFORE SEEDING BY TRACKING. 2.5.TRACKING IS DONE BY OPERATING EQUIPMENT UP AND DOWN THE SLOPE TO LEAVE HORIZONTAL DEPRESSIONS IN THE SOIL. 3.MAINTENANCE STANDARDS 3.1.PERIODICALLY CHECK ROUGHENED, SEEDED, PLANTED AND MULCHED SLOPES FOR RILLS AND GULLIES, PARTICULARLY AFTER A SIGNIFICANT STORM EVENT. FILL THESE AREAS SLIGHTLY ABOVE THE ORIGINAL GRADE, THEN RE-SEED AND MULCH AS SOON AS POSSIBLE. NOTES: 50' 6" MIN. CONTOUR FURROWS GROOVES WILL CATCH SEED, FERTILIZER, MULCH, RAINFALL, AND DECREASE RUNOFF SURFACE ROUGHENING STD. PLAN - 213.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.PLASTIC COVERING MAY BE USED ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS. 1.2.PLASTIC IS PARTICULARLY USEFUL FOR PROTECTING CUT AND FILL SLOPES AND STOCKPILES. 1.3.CLEAR PLASTIC SHEETING MAY BE USED OVER NEWLY-SEEDED AREAS TO CREATE A GREENHOUSE EFFECT AND ENCOURAGE GRASS GROWTH. CLEAR PLASTIC SHOULD NOT BE USED FOR THIS PURPOSE DURING THE SUMMER MONTHS. 1.4.THIS METHOD SHALL NOT BE USED UPSLOPE OF AREAS THAT MIGHT BE ADVERSELY IMPACTED BY RUNOFF. SUCH AREAS INCLUDE STEEP AND UNSTABLE SLOPES. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.PLASTIC SHEETING SHOULD HAVE A MINIMUM THICKNESS OF 0.06 MILLIMETERS. 2.2.IF EROSION AT THE TOE OF A SLOPE IS LIKELY, A GRAVEL BERM, RIPRAP, OR OTHER SUITABLE PROTECTION SHALL BE INSTALLED AT THE TOE OF THE SLOPE IN ORDER TO REDUCE THE VELOCITY OF RUNOFF. 2.3.TIRES, SAND BAGS, OR EQUIVALENT MAY BE USED TO WEIGHT PLASTIC. 2.4.SEAMS BETWEEN SHEETS MUST OVERLAP A MINIMUM OF 12 INCHES AND BE WEIGHTED OR TAPED. 3.MAINTENANCE STANDARDS 3.1.TORN SHEETS MUST BE REPLACED AND OPEN SEAMS REPAIRED. 3.2.IF THE PLASTIC BEGINS TO DETERIORATE DUE TO ULTRAVIOLET RADIATION, IT MUST BE COMPLETELY REMOVED AND REPLACED. 3.3.WHEN THE PLASTIC IS NO LONGER NEEDED, IT SHALL BE COMPLETELY REMOVED. NOTES: 10' MAX.. 10' MAX. TOE IN SHEETING IN 4" x4" MIN. TRENCH PROVIDE ENERGY DISSIPATION AT TOE IF EROSION IS LIKELY SANDBAG (TYP.) PLASTIC COVERING STD. PLAN - 213.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT WOODEN STAKE LIVE STAKE ROLL SPACING DEPENDS ON SOIL TYPE AND SLOPE STEEPNESS STRAW ROLLS MUST BE PLACED ALONG SLOPE CONTOURS 4' 3'-30', SEE NOTE 2.3 SEDIMENT, ORGANIC MATTER, AND NATIVE SEEDS ARE CAPTURED BEHIND THE ROLLS ADJACENT ROLLS SHALL TIGHTLY ABUT 8"-10" DIA. 3"-5", SEE NOTE 2.2 NOTES: 1.CONDITIONS OF USE 1.1.INSTALL ON DISTURBED AREAS THAT REQUIRE IMMEDIATE EROSION PROTECTION. 1.2.USE ON SLOPES REQUIRING STABILIZATION UNTIL PERMANENT VEGETATION CAN BE ESTABLISHED. 1.3.CAN BE USED ALONG THE PERIMETER OF A PROJECT, AS A CHECK DAM IN UNLINED DITCHES AND AROUND TEMPORARY STOCKPILES. 1.4.WATTLES CAN BE STAKED TO THE GROUND USING WILLOW CUTTINGS FOR ADDED REVEGETATION. 1.5.RILLING CAN OCCUR BENEATH AND BETWEEN WATTLES IF NOT PROPERLY ENTRENCHED, ALLOWING WATER TO PASS BELOW AND BETWEEN WATTLES. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.IT IS CRITICAL THAT WATTLES ARE INSTALLED PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOUR. 2.2.NARROW TRENCHES SHOULD BE DUG ACROSS THE SLOPE, ON CONTOUR, TO A DEPTH OF 3 TO 5 INCHES ON CLAY SOILS AND SOILS WITH GRADUAL SLOPES. ON LOOSE SOILS, STEEP SLOPES, AND DURING HIGH RAINFALL EVENTS, THE TRENCHES SHOULD BE DUG TO A DEPTH OF 5 TO 7 INCHES, OR 1/2 TO 2/3 OF THE THICKNESS OF THE WATTLE. 2.3.START CONSTRUCTION OF TRENCHES AND INSTALLING WATTLES FROM THE BASE OF THE SLOPE AND WORK UPHILL. EXCAVATED MATERIAL SHOULD BE SPREAD EVENLY ALONG THE UPHILL SLOPE AND COMPACTED USING HAND TAMPING OR OTHER METHOD. CONSTRUCT TRENCHES AT CONTOUR INTERVALS OF 3 TO 30 FEET APART DEPENDING ON THE STEEPNESS OF THE SLOPE, SOIL TYPE, AND RAINFALL. THE STEEPER THE SLOPE THE CLOSER TOGETHER THE TRENCHES SHOULD BE CONSTRUCTED. VERTICAL DISTANCE BETWEEN WATTLES IS NOT TO EXCEED 10 FEET. 2.4.INSTALL THE WATTLES SNUGLY INTO THE TRENCHES AND ABUT TIGHTLY END TO END. DO NOT OVERLAP THE ENDS. 2.5.INSTALL STAKES AT EACH END OF THE WATTLE, AND AT 4 FOOT CENTERS ALONG THE ENTIRE LENGTH OF THE WATTLE. 2.6.IF REQUIRED, INSTALL PILOT HOLES FOR THE STAKES USING A STRAIGHT BAR TO DRIVE HOLES THROUGH THE WATTLE AND INTO THE SOIL. 2.7.AT A MINIMUM, WOODEN STAKES SHOULD BE APPROXIMATELY 3/4 X 3/4 X 24 INCHES. WILLOW CUTTINGS OR 3/8-INCH REBAR CAN ALSO BE USED FOR STAKES. 2.8.STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF THE WATTLE, LEAVING 2 TO 3 INCHES OF THE STAKE PROTRUDING ABOVE THE WATTLE. 3.MAINTENANCE STANDARDS 3.1.INSPECT WATTLES PRIOR TO FORECASTED RAIN, DAILY DURING EXTENDED RAIN EVENTS, AFTER RAIN EVENTS, WEEKLY DURING THE WET SEASON, AND AT TWO WEEK INTERVALS AT ALL OTHER TIMES OF THE YEAR. 3.2.REPAIR OR REPLACE SPLIT, TORN, RAVELING, OR SLUMPING WATTLES 3.3.REMOVE SEDIMENT ACCUMULATIONS WHEN EXCEEDING 1/2 THE HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND SURFACE. STRAW WATTLES STD. PLAN - 213.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 1.CONDITIONS OF USE 1.1.SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2.SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. 2.2.STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3.WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V 2.4.IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5.FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3.MAINTENANCE STANDARDS 3.1.ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2.IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3.IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4.SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5.IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. NOTES: JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC 2' MIN. 12" MIN. 4"x4" MIN. TRENCH BACKFILL TRENCH WITH NATIVE SOIL OR 3/4" TO 1-1/2" WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) 6' MAX. POST SPACING MAY BE INCREASED TO 8' IF WIRE BACKING IS USED AOS (ASTM D4751)30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491)0.02 SEC-1MINIMUM GRAB TENSILE STRENGTH (ASTM D4632)180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632)30% MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355)70% MIN. SILT FENCE STD. PLAN - 214.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT ATTACHMENT DETAILS: 1.GATHER FABRIC AT POSTS, IF NEEDED. 2.UTILIZE THREE TIES PER POST, ALL WITHIN TOP 8" OF FABRIC. 3.POSITION EACH TIE DIAGONALLY, PUNCTURING HOLES VERTICALLY A MINIMUM OF 1" APART. 4.HANG EACH TIE ON A POST NIPPLE AND TIGHTEN SECURELY. USE CABLE TIES (50 LBS) OR SOFT WIRE. TOP OF FABRIC BELT DIAGONAL ATTACHMENT DOUBLES STRENGTH FLOW STEEL SUPPORT POSTNOTES:1.POST SPACING: 7' MAX. ON OPEN RUNS 4' MAX. ON POOLING AREAS.2.POST DEPTH: AS MUCH BELOW GROUND AS FABRIC ABOVE GROUND.3.PONDING HEIGHT 24" MAX. ATTACH FABRIC TO UPSTREAM SIDE OF POST.4.DRIVE OVER EACH SIDE OF SILT FENCE 2 TO 4 TIMES WITH DEVICE EXERTING 60 P.S.I. OR GREATER.5.NO MORE THAN 24" OF A 36" FABRIC ROLL IS ALLOWED ABOVE GROUND.6.VIBRATORY PLOW IS NOT ACCEPTABLE BECAUSE OF HORIZONTAL COMPACTION. 100% COMPACTION EACH SIDE OPERATION SILT FENCE TOP 8" 200-300mm 8"-12")ROLL OF SILT FENCE PLOW FABRIC ABOVE GROUND SLICING BLADE (18mm (11/ 16") WIDTH)HORIZONTAL CHISEL POINT (76mm ( 3") WIDTH)SILT FENCE INSTALLATION BY SLICING STD. PLAN - 214.10 PUBLIC WORKS DEPARTMENTAPPROVED: DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6-602A-4E4A- B436-A317AA638878 9/28/2018 | 9:45 PLAN VIEW ELEVATION VIEW SECTION A NOTES: 6" SEWER PIPE WITH BUTTERFLY VALVES 8'x8' SUMP WITH 5' OF CATCH TO ACCOMMODATE CLEANING BY TRACKHOE 3" TRASH PUMP WITH FLOATS ON SUCTION HOSE 2" SCH 40 1 1/2" SCH 40 FOR SPRAYERS MIDPOINT SPRAY NOZZLES, IF NEEDED 2% SLOPE5H:1V5H:1V2% SLOPE 1H:1V1H:1V15' ATB APRON TO PROTECT GROUND FROM SPLASHING WATER ATB CONSTRUCTION ENTRANCE ASPHALT CURB ON THE LOW ROAD SIDE TO DIRECT WATER BACK TO POND 6" SLEEVE UNDER ROAD BALL VALVE ( TYP.)CURB 6" SLEEVE 15'15'20' 15' 50' 5' 18' 12' 3' 1 1 LOCATE INVERT OF TOP PIPE 12" TO 14" ABOVE BOTTOM OF WHEELWASH 8'x8' SUMP TO ACCOMMODATE CLEANING BY TRACKHOE DRAIN PIPE WITH BUTTERFLY VALVE WATER LEVEL,12" TO14" DEEPA6" ATB OVER CRUSHED BASE MATERIAL OR 8" ATB OVER A GOOD SUBGRADE 5% - 10% SLOPE1.CONDITIONS OF USE 1.1.WHEN A STABILIZED CONSTRUCTION ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, WHEEL WASHING IS GENERALLY AN EFFECTIVE EROSION AND SEDIMENT CONTROL METHOD AND BMP WHEN INSTALLED WITH CAREFUL ATTENTION TO TOPOGRAPHY.2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1.USE A LOW CLEARANCE TRUCK TO TEST THE WHEEL WASH BEFORE PAVING. EITHER A BELLY DUMP OR LOWBOY WILL WORK WELL TO TEST CLEARANCE.2.2.MIDPOINT SPRAY NOZZLES ARE ONLY NEEDED IN VERY MUDDY CONDITIONS.2.3.POLYACRYLAMIDE (PAM) ADDED TO WHEEL WASHWATER AT A RATE OF 0.25-0.5 POUNDS PER 1,000 GALLONS OF WATER INCREASES EFFECTIVENESS AND REDUCES CLEANUP TIME. IF PAM IS ALREADY BEING USED FOR DUST OR EROSION CONTROL AND IS BEING APPLIED BY A WATER TRUCK, THE SAME TRUCK MAY BE USED TO CHANGE THE WASHWATER.3.MAINTENANCE STANDARDS 3.1.THE WHEEL WASH SHOULD START OUT EACH DAY WITH CLEAN, FRESH WATER.3.2.THE WASHWATER SHOULD BE CHANGED A MINIMUM OF ONCE PER DAY. ON LARGE EARTHWORK JOBS WHERE MORE THAN 10 TO 20 TRUCKS PER HOUR ARE EXPECTED,THE WASHWATER WILL NEED TO BE CHANGED MORE OFTEN.3.3.WHEEL WASH OR TIRE BATH WASHWATER SHALL BE DISCHARGED TO A SEPARATE ONSITE TREATMENT SYSTEM, SUCH AS A CLOSED- LOOP RECIRCULATION SYSTEM OR LAND APPLICATION, OR TO THE SANITARY SEWER SYSTEM WITH PROPER APPROVAL AND/OR PERMITS FROM KING COUNTY AND THE CITY OF RENTON. WHEEL WASH AND PAVED CONSTRUCTION ENTRANCE STD. PLAN - 215. 00 PUBLICWORKS DEPARTMENT APPROVED:DATEGregg Zimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)DocuSign Envelope ID: 6EECF5B6- 602A-4E4A-B436-A317AA638878 9/28/2018 | 2H:1V MAX 3H: 1V MAX.3H:1V MAX 1.CONDITION OF USE 1.1.A SEDIMENT POND SHALL BE USED WHERE THE CONTRIBUTING DRAINAGE AREA IS 3 ACRES OR MORE.2.DESIGN AND INSTALLATION SPECIFICATIONS 2.1.THE POND SHALL BE DIVIDED INTO TWO ROUGHLY EQUAL VOLUME CELLS BY A PERMEABLE DIVIDER THAT WILL REDUCE TURBULENCE WHILE ALLOWING MOVEMENT OF WATER BETWEEN CELLS. THE DIVIDER SHALL BE AT LEAST ONE HALF OF THE HEIGHT OF THE RISER. WIRE - BACKED, 2-TO 3 FOOT HIGH, EXTRA STRENGTH FILTER FABRIC SUPPORTED BY TREATED 4"X4"s MAY BE USED AS A DIVIDER. ALTERNATIVELY, STAKED STRAW BALES WRAPPED WITH FILTER FABRIC MAY BE USED.2.2.IF THE POND IS MORE THAN 6 FEET DEEP, A DIFFERENT MECHANISM MUST BE PROPOSED.2.3.TO AID IN DETERMINING SEDIMENT DEPTH, ONE- FOOT INTERVALS SHALL BE PROMINENTLY MARKED ON THE RISER.3.MAINTENANCE STANDARDS 3.1.SEDIMENT SHALL BE REMOVED FROM THE POND WHEN IT REACHES 1 FOOT IN DEPTH.3.2.ANY DAMAGES TO THE POND EMBANKMENTS OR SLOPES SHALL BE REPAIRED.NOTES:POND LENGTH (3 TO 6 TIMES THE MAX. POND WIDTH)SILT FENCE OR EQUIVALENT DIVIDER RISER PIPE INFLOW KEY DIVIDER INTO SLOPE TO PREVENT FLOW AROUND SIDES EMERGENCY OVERFLOW SPILLWAY DISCHARGE TO STABILIZED CONVEYANCE, OUTLET, OR LEVEL SPREADER 6' MIN.12" MIN. 12"CREST OF EMERGENCY SPILLWAY RISER PIPE (PRINCIPAL SPILLWAY),OPEN AT TOP WITH DEBRIS BARRIER,SEE STD. PLAN 234.20 DEWATERING DEVICE SEE RISER DETAIL,STD. PLAN 216.10)DEWATERING ORIFICE CONCRETE BASE DISCHARGE TO STABILIZED CONVEYANCE, OUTLET, OR LEVEL SPREADER EMBANKMENT COMPACTED 95%.PERVIOUS MATERIALS SUCH AS GRAVEL OR CLEAN SAND SHALL NOT BE USED WIRE- BACKED SILT FENCE, STAKED HAY BALES WRAPPED WITH FILTER FABRIC, OR EQUIVALENT DIVIDER 3. 5'MIN.SEDIMENT POND PLAN VIEW AND CROSS SECTIONSSTD. PLAN - 216.00 PUBLICWORKS DEPARTMENT APPROVED:DATEMartinPastuchaPublicWorks Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE ( NTS)DocuSign Envelope ID: 3B1B34D3-7E0A-476C- POLYETHYLENE CAP PROVIDE ADEQUATE STRAPPING CORRUGATED METAL RISER TACK WELD WATERTIGHT COUPLING PERFORATED POLYETHYLENE DRAINAGE TUBING, DIAMETER 2" MIN. LARGER THAN DEWATERING ORIFICE. TUBING SHALL COMPLY WITH ASTM F667 AND AASHTO M294 CONCRETE BASE ALTERNATIVELY, METAL STAKES AND WIRE MAY BE USED TO PREVENT FLOTATION) DEWATERING ORIFICE, SCH 40 STEEL STUB, MIN. DIAMETER AS PER CALCULATIONS IN SECTION D.2.1.5.2 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL 3.5' MIN. 6" MIN. 18" MIN. 2 x RISER DIA. MIN. 1.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. NOTES: RISER PIPE (PRINCIPAL SPILLWAY) OPEN AT TOP WITH DEBRIS BARRIER, SEE STD. PLAN 234.20 SEDIMENT POND RISER DETAIL STD. PLAN - 216.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartinPastucha Public Works Administrator UNLESSOTHERWISE NOTED, DRAWINGISNOTTOSCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT NOTES: SECTION VIEW ISOMETRIC VIEW DRAINAGE GRATE TRIM GRATE FRAME FILTERED WATER SEDIMENT AND DEBRIS OVERFLOW BYPASS BELOW INLET GRATE DEVICE DRAINAGE GRATE RECTANGULAR GRATE SHOWN)RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) BELOW INLET GRATE DEVICE 1.PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2.INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3.THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4.SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5.THE BIGD SHALL HAVE A BUILT-IN HIGH-FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6.THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7.PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). 8.ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. 5" MAX. CATCH BASIN INSERT STD. PLAN - 216.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLAN VIEW NOTES: 1.PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2.INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3.THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4.USE BLOCK AND GRAVEL TYPE SEDIMENT BARRIER WHEN CURB INLET IS LOCATED IN GENTLY SLOPING SEGMENT, WHERE WATER CAN POND AND ALLOW SEDIMENT TO SEPARATE FROM RUNOFF. 5.BARRIER SHALL ALLOW FOR OVERFLOW FROM SEVERE STORM EVENT. 6.INSPECT BARRIERS AND REMOVE SEDIMENT AFTER EACH STORM EVENT. SEDIMENT AND GRAVEL MUST BE REMOVED FROM THE TRAVELED WAY IMMEDIATELY. 7.BLOCK AND GRAVEL CURB INLET PROTECTION MAY ONLY BE USED IN LANES NOT OPEN TO TRAFFIC. SECTION A CATCH BASIN OVERFLOW WATER CATCH BASINCOVERBACKOFSIDEWALK 2"x4" WOOD STUD CURB INLET CONCRETEBLOCKSWIRESCREENORFILTERFABRIC 3/4" DRAIN GRAVEL WIRE SCREEN OR FILTER FABRIC 3/4" DRAIN GRAVEL POND HEIGHT 2"x4" WOOD STUD CATCH BASIN COVER CURBINLETA BLOCK AND GRAVEL CURB INLET PROTECTION STD. PLAN - 216.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT RUNOFF RUNOFF SPILLWAY NOTES: 1.PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2.INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3.THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4.PLACE CURB TYPE SEDIMENT BARRIERS ON GENTLY SLOPING STREET SEGMENTS, WHERE WATER CAN POND AND ALLOW SEDIMENT TO SEPARATE FROM RUNOFF. 5.SANDBAGS OF EITHER BURLAP OR WOVEN GEOTEXTILE FABRIC, SHALL BE FILLED WITH GRAVEL, LAYERED AND PACKED TIGHTLY. 6.LEAVE A ONE SANDBAG GAP IN THE TOP ROW TO PROVIDE A SPILLWAY FOR OVERFLOW. 7.INSPECT BARRIERS AND REMOVE SEDIMENT AFTER EACH STORM EVENT. SEDIMENT AND GRAVEL MUST BE REMOVED FROM THE TRAVELED WAY IMMEDIATELY. 8.CURB AND GUTTER BARRIER PROTECTION MAY ONLY BE USED IN LANES NOT OPEN TO TRAFFIC. BACK OF SIDEWALK CURB INLET CURB FACE GUTTER DRAIN GRATE SANDBAGS TO OVERLAP ONTO CURB GRAVEL FILLED SANDBAGS STACKED TIGHTLY CURB AND GUTTER BARRIER PROTECTION STD. PLAN - 216.50 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT A B 1.CONDITIONS OF USE 1.1.WHERE THERE IS CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM SEDIMENT PONDS OR TRAPS. 1.2.TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON-EROSIVE DISCHARGE POINT. 2.MAINTENANCE STANDARDS 2.1.ANY SEDIMENT DEPOSITION OF MORE THAN 6 INCHES SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL DESIGN CAPACITY. 2.2.THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION HAS OCCURRED, AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET OR NET. NOTES: ROCK MUST COMPLETELY COVER THE BOTTOM AND SIDES OF THE DITCH 6" MIN. 24" MIN. L = THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION L 2"-4" ROCK 2 1 2 1 SECTION A SECTION B CHECK DAM (TYP.) PLANAB 18" MIN. FLOW DITCH BOTTOM OF DITCH 18" MIN. DITCH CHECK DAMS STD. PLAN - 217.40 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT RIGID PIPE NOTES: 1.PIPE COMPACTION LIMITS SHOWN ON THIS PLAN ARE FOR PIPE CONSTRUCTION IN AN EMBANKMENT. FOR PIPE CONSTRUCTION IN A TRENCH, THE HORIZONTAL LIMITS OF THE PIPE COMPACTION ZONE SHALL BE THE WALLS OF THE TRENCH. 2.O.D. IS EQUAL TO THE OUTSIDE DIAMETER OF A PIPE OR THE OUTSIDE SPAN OF PIPE-ARCH. 3.SEE STANDARD WSDOT/APWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH. 4.PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6" LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 5.EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR BPER STANDARD WSDOT/APWA SPECIFICATIONS SECTION 9-03.17. GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)) OR MAINTENANCE ROCK (WSDOT 9-03.9(4)) CIRCULAR PIPE FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 5 SPAN 6" PIPE - ARCH 6" PIPE TYPE MINIMUM COVER (FT)PUBLIC?PRIVATE?ALLOWED IN ZONE 1 OF THE APA? CORRUGATED STEEL PIPE 2.0 YES YES YES SPIRAL RIB STEEL PIPE 2.0 YES YES YES PLAIN CONCRETE PIPE (PCP)2.0 NO YES NO REINFORCED CONCRETE PIPE RCP) 1.0 YES YES NO CORRUGATED OR SPIRAL RIB ALUMINUM PIPE 2.0 YES YES NO DUCTILE IRON PIPE 1.0 YES YES YES FOUNDATION LEVEL RISE TRENCH WIDTH, SEE NOTE 3 CIRCULAR PIPE DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 12" TO 24"12" 30" TO 96"DIAMETER / 3 102" TO 180"48" PIPE-ARCH SPAN MINIMUM DISTANCE BETWEEN BARRELS 18" TO 36"12" 43" TO 142"SPAN / 3 148" TO 199"48" TRENCH WIDTH, SEE NOTE 3 6" O.D. 6" FOUNDATION LEVEL PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 4 FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 5 PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 4 PIPE ZONE BEDDING AND COMPACTION - RIGID PIPE STD. PLAN - 220.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT FLEXIBLE PIPE NOTES: 1.PROVIDE UNIFORM SUPPORT UNDER BARRELS. 2.HAND TAMP UNDER HAUNCHES. 3.DIRECTLY OVER PIPE, HAND TAMP ONLY. 4.SEE STANDARD WSDOT/APWA SPECIFICATIONS SECTION 2-09.4 FOR TRENCH WIDTH. 5.PIPE ZONE BEDDING AND BACKFILL MATERIAL SHALL BE PLACED IN 6" LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY. 6.EXCAVATE UNSTABLE MATERIAL DOWN TO FIRM SOIL AND REPLACE WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD WSDOT/APWA SPECIFICATIONS SECTION 9-03.17. SEE NOTE 4, LIMIT OF PIPE ZONE 6" O.D. 6" FOUNDATION LEVEL PIPE ZONE BEDDING AND BACKFILL, SEE NOTE 5 FLEXIBLE PIPE PIPE TYPE MINIMUM COVER (FT)PUBLIC?PRIVATE?ALLOWED IN ZONE 1 OF THE APA? LINE CORRUGATED POLYETHYLENE PIPE (LCPE)2.0 YES YES YES CORRUGATED POLYETHYLENE PIPE (CPE) - TRIPLE WALL 2.0 YES YES YES POLYVINYL CHLORIDE PIPE (PVC)3.0 YES YES YES SOLID WALL HIGH DENSITY POLYETHYLENE PIPE (HDPE)2.0 YES YES YES POLYPROPYLENE PIPE (PP) - DUAL WALL 2.0 YES YES YES DIAMETER MINIMUM DISTANCE BETWEEN BARRELS 12" TO 24"12" 30" TO 96"DIAMETER / 3 102" TO 180"48" GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3)) OR MAINTENANCE ROCK (WSDOT 9-03.9(4)) FOUNDATION MATERIAL, IF REQUIRED, SEE NOTE 6 PIPE ZONE BEDDING AND COMPACTION - FLEXIBLE PIPE STD. PLAN - 220.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartinPastucha Public Works Administrator UNLESSOTHERWISE NOTED, DRAWINGISNOTTOSCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT 12" MIN. 6" MIN. , SEE NOTE 4 EXISTING PAVEMENT SURFACE SURFACE RESTORATION AS SPECIFIED IN CONTRACT DOCUMENTS CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03.9(3), "BANK RUN GRAVEL FOR TRENCH BACKFILL" PER WSDOT STD. SPEC 9-03.19, OR "GRAVEL BORROW" PER WSDOT STD. SPEC 9-03.14(1), COMPACTED TO 95% OF MAXIMUM DENSITY BENCH AS NEEDED FOR SHORING SYSTEM WHEN DEPTH IS 4' OR GREATER PIPE ZONE BEDDING AND BACKFILL PER STD. PLANS 220.00 AND 220.10 PIPE NEAT LINE TRENCH UNPAVED AREAS PAVED AREAS SEE NOTE 1 NOTES: 1.SEE WSDOT/APWA STANDARD SPECIFICATIONS SECTION 2-09.4FOR MEASUREMENT OF TRENCH WIDTH. 2.EXCAVATIONS OVER 4' DEEP SHALL COMPLY WITH THE SAFETY STANDARD DESCRIBED IN CHAPTER 295-155 PART N OF THE WAC. 3.MAXIMUM BACKFILL DEPTH ABOVE PIPE SHALL NOT BE EXCEEDED, AS DETERMINED BY PIPE MANUFACTURER. 4.IN PAVED AREAS, IF PIPE HAS LESS THAN 3' OF COVER, USE "CRUSHED SURFACING TOP COURSE" FOR THE ENTIRE BACKFILL DEPTH ABOVE PIPE ZONE. 5.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. SEE STANDARD PLANS 110, 110.1, 110.2, AND 111 FOR PAVEMENT RESTORATION REQUIREMENTS CRUSHED SURFACING TOP COURSE" PER WSDOT STD. SPEC 9-03.9(3), COMPACTED TO 95% OF MAXIMUM DENSITY TYPICAL TRENCH AND BACKFILL STD. PLAN - 220.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT TYPICAL CLEANOUT CONFIGURATION GENERAL NOTES: 1.CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2.ALL FITTINGS SHALL BE SOIL TIGHT. 3.CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4.CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY. DESIGN PONDING ELEVATION SOIL TIGHT 45° BEND EXTEND CLEANOUT RISER 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN 4" STREAMBED COBBLES PER WSDOT 9-03.11(2) SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE, SEE NOTE 1 WYE MECHANICAL PLUG OR CONTINUED CONNECTION FERNCO GASKETED QUIK CAP OR SIMILAR CAST IRON FRAME AND COVER, SEE NOTE 3 CLEANOUT RISER, SEE NOTE 2 PAVED AREA (TYP.) TO OVERFLOW STRUCTURE OR STORM MAIN CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA NOTES: 1.DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2.CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE. 3.FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR DRAIN". 4.FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. CLEANOUT RISER, SEE NOTE 2 FRAME SECTION 10-1/2" DIA 4" 5/8"9" DIA 15" DIA 8-1/8" DIA 8-13/16" DIA 5/8" COVER SECTION MADE INUSA 1" PLAN VIEW PROD NO.3/4" FLAT FACE GOTHIC 2) 3/8"-16 SS SOCKET HEAD CAP SCREW (ALLENHEAD) W/WSHRS ON A 8" DIA BOLT CIRCLE 1) OPENPICKHOLE 12"12"4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03. 12(4)8" CLASS "B"ASPHALT, SEE NOTE 4 STORM SYSTEM CLEANOUT STD. PLAN - 226.00 PUBLIC WORKS DEPARTMENTAPPROVED: DATEMartin Pastucha Public WorksAdministrator UNLESS OTHERWISENOTED, DRAWINGISNOT TO SCALE (NTS)DocuSign Envelope ID: 3B1B34D3-7E0A-476C- ADB3-4329FFE0C108 8/13/2020 | 8:48 1.DIMENSIONS ARE FOR ILLUSTRATION OF 54" DIAMETER CB. FOR DIFFERENT DIAMETER CB'S ADJUST TO MAINTAIN 45°ANGLE OF VERTICAL" BARS AND 7" O.C. MAXIMUM SPACING OF BARS AROUND LOWER STEEL BAND. 2.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. PLAN VIEW NOTES: SECTION A A 3/4" DIAMETER SMOOTH BARS EQUALLY SPACED (4" O.C. MAX.) 4 HOOK CLAMPS EVENLY PLACED, SEE DETAIL PROVIDE MAINTENANCE ACCESS BY WELDING 4 CROSSBARS TO 4 VERTICAL BARS AS SHOWN. HINGE UPPER ENDS WITH FLANGES/BOLTS AND PROVIDE LOCKING MECHANISM PADLOCK) ON LOWER END. LOCATE STEPS DIRECTLY BELOW 3/4" DIA. SMOOTH ROUND BARS WELDED EQUALLY SPACED. BARS SHALL BE WELDED TO UPPER AND LOWER BANDS (24 BARS EVENLY SPACED, SEE NOTE 1) LOWER STEEL BAND 3/4" x 4" WIDE FORMED TO FIT IN GROOVE OF CATCH BASIN RISER 15° (TYP.), SEE NOTE 1 24", SEE NOTE 1 UPPER STEEL BAND 3/4" x 4" WIDE STANDARD STEPS OR LADDER, SEE NOTE 2 TYPE 2 CB SMOOTH VERTICAL BARS HOOK CLAMP ANCHORED TO CATCH BASIN RISER CATCH BASIN CB) RISER 45° HOOK CLAMP DETAIL OVERFLOW STRUCTURE / RISER WITH DEBRIS BARRIER STD. PLAN - 234.20 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartinPastucha Public Works Administrator UNLESSOTHERWISE NOTED, DRAWINGISNOTTOSCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT d ISOMETRIC SECTION A PLAN VIEW ELBOW RESTRICTOR DETAIL 1.USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2.OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. 3.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4.FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB-DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5.IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6.PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3'-0" VERTICAL SPACING). 7.LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8.LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10.IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. NOTES: 2" MIN. 6" MIN. 6" MAX. REMOVABLE WATERTIGHT COUPLING OR FLANGE PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED, SEE NOTE 3 DESIGN WATER SURFACE 16" MAX. 12" MIN. UNDER PAVEMENT 6" MIN. D 1.5 x D MIN.2' MIN. 2' MIN. 2' MIN. 12" 12" (TYP.) FRAME & SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 VERTICAL BAR GRATE FOR SECONDARY INLET HANDHOLDS, STEPS, OR LADDER SHEAR GATE WITH CONTROL ROD FOR CLEANOUT/DRAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER) PER STD. PLAN 237.30 INLETPIPEOUTLETPIPE, SEE NOTES 1 & 5 INVERT AND ELEVATION PER PLANS WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 2' MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS 2' MIN, ANGLE AS NECESSARY, SEE NOTE 7 ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WITH WATER ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 PIPE SUPPORTS, SEE NOTE 6 A ELEVATION PER PLANS SEE NOTE 9 (TYP.) 12" SECTION OF PIPE ATTACHED BY GASKETED BAND TO ALLOW REMOVAL FLOW CONTROL STRUCTURE - RESTRICTOR TEE STD. PLAN - 237.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartinPastucha Public Works Administrator UNLESSOTHERWISE NOTED, DRAWINGISNOTTOSCALE (NTS) DocuSign Envelope ID: 3B1B34D3-7E0A-476C-ADB3-4329FFE0C108 8/13/2020 | 8:48 AM PDT LEVEL LINE SEE NOTE 5 1.SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26-ZG-32a OR CAST IRON ASTM A48 CLASS 30B AS REQUIRED. 2.GATE SHALL BE 8 INCH DIA. UNLESS OTHERWISE SPECIFIED. 3.GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE), WELDING, OR OTHER SECURE MEANS. 4.LIFT ROD: AS SPECIFIED BY MFR. WITH HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD. 5.GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE. 6.NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. 7.MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT. 8.FLANGE MOUNTING BOLTS SHALL BE 3/8" DIA. STAINLESS STEEL. 9.ALTERNATE CLEANOUT/SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE AND HAVE A SIX BOLT, 10 3/8" BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION. LIFT HANDLE FRONT SIDE MAXIMUM OPENING OF GATE NOTES: 6) EVENLY SPACED HOLES ON 10 3/8" BOLT CIRCLE FOR BOLTING TO FLANGE CONNECTION HANDLE WITH LOCK PIN ADJUSTABLE LOCK HOOK WITH LOCK SCREW 1" ROD OR TUBING, VARIABLE LENGTH LIFT HANDLE SHALL BE ATTACHED PER MANUFACTURER'SRECOMMENDATIONSLEVEL LINETEE SECTION SHEAR GATE STD. PLAN - 237.30 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT PLAN WATER QUALITY WATER SURFACE SUBMERGED INLET PIPE AFTERBAYFOREBAY NOTES: 1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN CRITERIA. 2.GRAVITY DRAIN SHALL BE AT LEAST 8INCH MINIMUM DIAMETER AND SHALL BE CONTROLLED BY A VALVE . USE OF A SHEAR GATE IS ALLOWED ONLY AT THE INLET OF A PIPE LOCATED WITHIN AN APPROVED STRUCTURE. 3.ACCESS TO EACH COMPARTMENT IS REQUIRED, ON EACH END, AND EVERY 50 FEET MINIMUM. 4.VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR OTHERWISE COVERED, BUT DESIGNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION. 5.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 6.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. 20' MAX. RECOMMENDED) 5' MAX. HIGH FLOW BYPASS LADDER (TYP.) ACCESS COVER OVER OUTLET ACCESS COVER OVER INLET 12" MIN. VENTILATION PIPES AT CORNERS (TYP.) COALESCING PLATE RACK ACCESS DOOR ALLOWING REMOVAL OF PLATE PACK OR PROVIDE FULL LENGTH REMOVABLE COVERS ACROSS ENTIRE CELL SHUT OFF VALVE W / RISER AND VALVE BOX SECTION 20' MAX. 7' MIN. L/3 MIN. L/2 RECOMMENDED) L 8' MIN. L/4 RECOMMENDED) D 18" MIN. 12" MIN. 12" MIN. 6" MIN. 12" MIN. 6" MIN. VARIES (CAN BE CONSTRUCTED ON GRADE WITHOUT RISERS) 8" TEE OIL RETAINING BAFFLE (50% D MIN.) COALESCING PLATE RACK GRAVITY DRAIN INLET WEIR-SOLIDS RETAINING BAFFLE OR WINDOW WALL INLET PIPE 8" MIN.)SEE NOTE 5 (TYP.) 2' MIN. COVER OUTLET PIPE (8" MIN.) SEE NOTE 5 TYP.) SEE NOTE 5 (TYP.) SEE NOTE 5 (TYP.) COALESCING PLATE OIL / WATER SEPARATOR STD. PLAN - 240.10 PUBLIC WORKS DEPARTMENT APPROVED: DATEGreggZimmerman Public Works Administrator UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 9/28/2018 | 9:45 AM PDT 2% 1 2.5 MIN. 1 2.5 MIN. GENERAL NOTES: 1.MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 265.00, 265.10, AND 265.20, AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 2.BSM PLACEMENT, GRADING, AND CONSOLIDATION SHALL NOT OCCUR WHEN THE BSM IS EXCESSIVELY WET OR HAS BEEN SUBJECTED TO MORE THAN 1/2" OF PRECIPITATION WITHIN 48 HOURS PRIOR TO PLACEMENT. EXCESSIVELY WET IS DEFINED AS BEING AT OR ABOVE 22% SOIL MOISTURE BY A GENERAL TOOLS AND INSTRUMENTS DSMM500 PRECISION DIGITAL SOIL MOISTURE METER WITH PROBE (OR EQUIVALENT). THERE SHOULD BE NO VISIBLE FREE WATER IN THE MATERIAL. THE CONTRACTOR SHALL PLACE BSM LOOSELY WITH A CONVEYOR BELT OR WITH AN EXCAVATOR OR LOADER FROM A HEIGHT NO HIGHER THAN 6 FEET, UNLESS OTHERWISE APPROVED BY THE ENGINEER (I.E., DO NOT DUMP MATERIAL DIRECTLY FROM TRUCK INTO CELL). COMPACT BSM USING NON-MECHANICAL COMPACTION METHODS (E.G., BOOT PACKING, HAND TAMPING, OR WATER CONSOLIDATION) TO 83% (± 2%) OF THE MAXIMUM DRY DENSITY PER MODIFIED PROCTOR TEST (ASTM D1557), OR AS DIRECTED BY THE ENGINEER. 3.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. NOTES: 1.AVOID COMPACTION OF EXISTING SUBGRADE BELOW BASIN. 2.SCARIFY SUBGRADE TO A DEPTH OF 3 INCHES MINIMUM IMMEDIATELY PRIOR TO PLACEMENT OF BIORETENTION SOIL MIX (BSM) AND UNDERDRAIN AGGREGATE. 3.18" MIN. BIORETENTION SOIL MIX ON BOTTOM AND SIDES TO TOP OF PONDING AREA. BIORETENTION SOIL MIX TO MEET STD. PLAN 262.60. 4.ARBORIST WOOD CHIP MULCH TO MEET STD. PLAN 262.60. 5.DO NOT USE FILTER FABRIC BETWEEN SUBGRADE AND THE BIORETENTION SOIL MIX. 6.MAXIMUM LONGITUDINAL SLOPE (ALONG DIRECTION OF FLOW) OF BIORETENTION SWALES SHALL BE 6%. 7.WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6 INCHES MINIMUM AND INCREASE SIDE SLOPE TO 1.5H:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. 1.5 1 FOR EDGE TREATMENT OPTIONS, SEE STD. PLAN 262.20 ROADWAY OR PARKING LOT TRANSITION ZONE SOIL, SEE STD. PLAN 262.20 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, SEE NOTE 4 OVERFLOW TO STORM MAIN SIDEWALK, LANDSCAPING, DRIVEWAY, OR PAVEMENT ANGLE OF REPOSE DESIGNER TO SPECIFY WATER STORAGE ELEVATION TOP OF BANK ELEVATION SCARIFIED AND UNCOMPACTED SUBGRADE, SEE NOTES 1AND 2 OVERFLOW STRUCTURE PER STD. PLAN 262.40 UNLESS SPECIFIED OTHERWISE BIORETENTION SOIL MIX (BSM), SEE NOTE 3 GRAVEL BASE, SEE STD. PLAN 262.40 SEE STD. PLAN 262.20 1" 6" 2"-12" PONDING DEPTH 18" MIN. SEE STD. PLAN 262.20 BOTTOM WIDTH MIN. 18" 6" MIN. FREEBOARD 12" MIN. ABOVE SEASONAL HIGH GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER SIDE SLOPE AT TREE, SEE NOTE 7 BIORETENTION SECTION NO UNDERDRAIN) STD. PLAN - 262.00 PUBLIC WORKS DEPARTMENT APPROVED: DATEMartinPastucha Public Works Administrator UNLESSOTHERWISE NOTED, DRAWINGISNOTTOSCALE (NTS) DocuSign Envelope ID: A9707D3B-A0EF-441F-8140-2CDB48E878CA 11/2/2020 | 1:04 PM PST PLAN VIEW OF PARCEL TO STORM DRAINSYSTEMRIGHT- OF-WAYGENERAL NOTES:1.INFILTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM SINGLE-FAMILY OR DUPLEX HOMES OR TO CONTROL BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROL PROGRAM (UIC) FOR OTHER TYPES OF RUNOFF MANAGEMENT.2.IMPERVIOUS AREAS LARGER THAN 10,000 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 35,000 SF MAY REQUIRE LARGER PIPE AND SHOULD BE DESIGNED BY A CIVIL ENGINEER.3.THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25%.4.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.24" MIN.18" MIN.MIN. 1' ABOVE SEASONAL HIGH GROUNDWATER TABLE 6" MIN.3/4" - 11/2" WASHED DRAIN ROCK OR GRAVEL BACKFILL FOR DRYWELLS PER WSDOT STD.SPECIFICATION SECTION 9-03.12( 5)NON-WOVEN GEOTEXTILE FOR SEPARATION ON TOP AND SIDES OF TRENCH PER WSDOT SPECIFICATIONS SECTION 9-33.2(1) TABLE 3 COMPACTED TOPSOIL OR OTHER CLEAN FILL 6" DIA. MIN.PERFORATED PVC,SDR 35 PER ASTM D3034 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL ASECTION A NOTES:1.TRENCH LENGTH TO BE 10 FEET IN LENGTH FOR EVERY 5,000 SF OF CONTRIBUTING IMPERVIOUS SURFACE, OR 35,000 SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTION THEREOF. 5' MIN. 5' MIN.TO STORM DRAIN SYSTEM 5' MIN. 5' MIN. A DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 CONFIGURATION ON FLAT GROUND CONFIGURATION ON SLOPING GROUND UNDISTURBED NATIVE SOIL CLEANOUT PER STD. PLAN 226. 00 CLEANOUT PER STD. PLAN 226. 00 FILTER SCREEN 2'-5' TO GROUND SOLIDS/ LEAVES TYPICAL DOWNSPOUT FILTER DETAIL FOOTING DRAIN BYPASS CLEANOUT PER STD. PLAN 226. 00 PERFORATED STUB- OUT CONNECTION PUBLIC WORKS DEPARTMENT APPROVED:DATEMartin Pastucha Public Works AdministratorUNLESS OTHERWISE NOTED, DRAWINGISNOTTO SCALE ( NTS)STD. PLAN - 263. 40 DocuSign Envelope ID: A9707D3B-A0EF-441F-8140- 2CDB48E878CA 11/2/2020 | 1:04 PM 10 FT EXISTING WATER LINE TESTING DETAIL EXISTING TEE, DEAD END LINE, CAP OR PLUG DO NOT DISTURB BLOCKING NEW WATER LINE U 2F VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1—BLIND FLANGE ON TOP WITH 2"TAP & 2"PLUG 1—BLIND FLANGE ON BOTTOM 1—PLUG(MJ) W/2"TAP & 2" BLOW—OFF TEMP. BLOCK FINAL CONNECTION DETAIL EXIST. WATER LINE NEW WATER LINE 0 r— AFTER ALL TESTING, CLEANING BY POLYPIG AND DISINFECTION, REMOVE TEMP. BLOCK & BLOW—OFF & CONNECT TO EXISTING WATER LINE WITH SLEEVE (MJ) AND D.I. SPOOLS FINAL CONNECTION BY CITY FORCES Y STD. PLAN — 300.50as + PUBLIC WORKS CONNECTION TO WATER MAIN DEPARTMENT EXISTING TEE OR END LINE CAP N,tp MARCH 2010 FIRE HYDRANT SHALL BE COREY—TYPE EQUAL TO IOWA F-5110 OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929, MUELLER SUPER CENTURION 200, AND WATEROUS PACER WITH 6" MECHANICAL JOINT INLET WITH LUGS. 5-1/4" MAIN VALVE OPENING. TWO 2-1/2" HOSE CONNECTIONS NATIONAL STANDARD THREADS. 4" PUMPER CONNECTION CITY OF SEATTLE THREADS WITH A STORZ ADAPTOR, 4.875" SEATTLE THREAD X 5" STORZ, ATTACHED WITH 1/8" STAINLESS STEEL CABLE. 1-1/4" PENTAGON OPERATING NUT. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF PAINT. KELLY— MOORE/PRESERVATIVE PAINT No. 5780-563 DTM ACRYLIC GLOSS, SAFETY YELLOW OR APPROVED EQUAL. PUMPER CONNECTION TO FACE ROADWAY OR AS DIRECTED BY RENTON FIRE DEPARTMENT. FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. MIN. 18" TO 20" BEHIND BACK OF CURB OR 12" BEHIND BACK OF 3' SIDEWALK THAT IS ADJACENT TO CURB 4.875" x 5" STORZ 5'x5'x6" THICK CONCRETE PAD AROUND HYDRANT. FINISH TO MATCH SIDEWALK. E EXPANSION JOINT AT 2` 1 BACK OF SIDEWALK fCONCRETE SIDEWALK OR PLANTING STRIP 36" MIN COVER TWO—PIECE CAST IRON VALVE BOX WITH LUG TYPE COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH TO FIT. VALVE NUT EXTENSION AS REQUIRED. RAISED PAVEMENT MARKER TYPE 88—A STIMSONITE TWO—WAY BLUE REFLECTIVE CONCRETE BLOCKING CONCRETE ' . THRUST BLOCK MAIN LINE TEE. WITH 6" FLANGE SIDE OUTLET. 6" GATE VALVE (FL X MJ) AWWA C-509, RESILIENT SEAT 6" DUCTILE IRON PIPE, CLASS 52 CEMENT LINED, LENGTH TO FIT 2-3/4" COR—TEN STEEL TIE RODS. 16" x 8" x 4" MININUM X1/2 YARD OF 1-1/4" WASHED DRAIN ROCK CONCRETE BEARING 1' ABOVE BOOT FLANGE. PLACE 8 MILBLOCKUNDERHYDRANTPOLYETHYLENEFILMAROUNDTOPAND SIDES OF GRAVEL. 1 O FIRE HYDRANT ASSEMBLY CUT D ONE MAN ROCK - 1 6 TE PAD LEVEL ALL GROUND MIN 3' RADIUS a elk 6" CONCRETE PAD FI LL HYDRANT LOCATION IN CUT OR FILL ZY STD. PLAN — 310.1 e + PUBLIC WORKS FIRE HYDRANT ASSEMBLYODEPARTMENT N,yp MARCH 2010 1-1/2" AND 2" WATER SERVICE DETAIL CAUTION: VALVE BOX SHOULD NOT REST ON PIPE. LATER COMPACTION IN AREA OF VALVE BOX COULD CAUSE THE BREAKAGE OF THE SERVICE. CITY PIPING w C Z zJJ IN UNIMPROVED RIGHT—OF—WAY INSTALL METER a BOX AT PROPERTY LINE WITH ii0 12" LONG COPPER TAILPIECE 0 Xo_ Ofo_ COUPLING x MIPT CAST IRON OR DUCTILE IRON WATERMAIN 9" MIN. 12" MAX. z za Qg ? W 3 M:2> 0 4 o, LEAVE EXPOSED : 0 0Nr) 12„ BY PASS NOT ALLOWED o FOR IRRIGATION METERS MATERIAL LIST FOR 2" SERVICE: METER LOCATED IN PLANTING STRIP BETWEEN CURB & SIDEWALK 1. 2" tapped tee, on new water main. 2. 4" long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat gate valve with threaded ends, square operating nut, and valve nut extension if required (see standard detail 330.1). 4. Two piece cast iron valve box. Standard 8" top section with regular base section, length to fit, "lug" type cover. 2" brass bushing (MIPT x FIPT). 5. 2 each 2" brass or bronze nipples 6" length, threaded ends. 2 each 2"-90° brass or bronze elbows (FIPT x FIPT). 6. 2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to fit. 8. 2" threaded brass 90' ell. 9. 2" Customsetter with by—pass Ford: VBH 86-12B-11-77 (x 17-3/16" McDonald Brass: 30B715WDFF775 or Mueller B-1427-2", with flanged angle ball valve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and purity tests. 12. 17"x30" Plastic meter box equal to Mid—States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31" equal to Mid—States Plastics, Inc. MSCBC-1730—R with 2" drilled hole for touchread pit lid, and meter read lid. 13. 2" coupling (compression x FIPT) with 2" plug (MIPT), Ford C-14-66 or equal. The property owner is responsible for any necessary adaptation or extension of water service. NOTE: ALL METER BOXES INSTALLED IN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST—IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH SIDES OF METER BOX. PRIVATE PIPING MATERIAL LIST FOR 1-1/2" SERVICE: METER LOCATED IN PLANTING STRIP BETWEEN CURB & SIDEWALK 1. 2" tapped tee on new water main. 2. 4" long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat gate valve with threaded ends, square operating nut, and valve nut extension if required (see standard detail 330.1). 4. Two piece cast iron valve box. Standard 8" top section with regular base section, length to fit, "lug" type cover. 5. 2" X 1-1/2" hex brass bushing (MIPT x FIPT. 2 each 1-1/2" brass or bronze nipples 6" length, threaded ends. 2 each 1-1/2"-90° brass or bronze elbows (FIPT x FIPT. 6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 1-1/2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to fit. 8. 1-1/2" threaded brass 90° ell, for Ford L44-77 or equal. 9. 1-1/2" Customsetter with by—pass Ford: VBH 86-12B-11-66 (x 13-3/16"), McDonald Brass: 3OB612WDFF665 or Mueller B-1427-1 1/2", with flanged angle ball valve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and purity tests. 12. 17"x30" Plastic meter box equal to Mid—States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31" equal to Mid—States Plastics, Inc. MSCBC-1730—R with 2" drilled hole for touchread pit lid. 13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford C-14-66 or equal. The property owner is responsible for any necessary adaptation or extension of water service. ZY e + PUBLIC WORKS 1 %2" AND 2" WATER SERVICE LOCATED STD. PLAN — 320.2 O DEPARTMENT IN PLANTING STRIP N,yp MARCH 2010 CRUSHED ROCK J BASE TO SUPPORT AVAULT. A DRILL 2" DIA. HOLE FOR TOUCHREAD DEVICE QUICK—JOINT COUPLING x MIPT CAST IRON OR DUCTILE IRON WATERMAIN 2-1/2" MIN. FROM NEAREST NOTE: AND FRONT EDGE OF PIT LID THE CENTER OF THE HOLE MUST BE AT LEAST 1" FROM UNDERNEATH RIBS UNLESS THE RIB SPACING ALLOWS THE NUT TO TIGHTEN AGAINST THE OPEN SIDE OF MORE THAN ONE RIB. TYPICAL RIB MATERIAL LIST FOR 2" SERVICE: METER LOCATED IN PLANTING STRIP BETWEEN CURB & SIDEWALK 1. 2" tapped tee, on new water main. 2. 4" long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat gate valve with threaded ends, square operating nut, and valve nut extension if required (see standard detail 330.1). 4. Two piece cast iron valve box. Standard 8" top section with regular base section, length to fit, "lug" type cover. 2" brass bushing (MIPT x FIPT). 5. 2 each 2" brass or bronze nipples 6" length, threaded ends. 2 each 2"-90° brass or bronze elbows (FIPT x FIPT). 6. 2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to fit. 8. 2" threaded brass 90' ell. 9. 2" Customsetter with by—pass Ford: VBH 86-12B-11-77 (x 17-3/16" McDonald Brass: 30B715WDFF775 or Mueller B-1427-2", with flanged angle ball valve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and purity tests. 12. 17"x30" Plastic meter box equal to Mid—States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31" equal to Mid—States Plastics, Inc. MSCBC-1730—R with 2" drilled hole for touchread pit lid, and meter read lid. 13. 2" coupling (compression x FIPT) with 2" plug (MIPT), Ford C-14-66 or equal. The property owner is responsible for any necessary adaptation or extension of water service. NOTE: ALL METER BOXES INSTALLED IN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST—IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH SIDES OF METER BOX. PRIVATE PIPING MATERIAL LIST FOR 1-1/2" SERVICE: METER LOCATED IN PLANTING STRIP BETWEEN CURB & SIDEWALK 1. 2" tapped tee on new water main. 2. 4" long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat gate valve with threaded ends, square operating nut, and valve nut extension if required (see standard detail 330.1). 4. Two piece cast iron valve box. Standard 8" top section with regular base section, length to fit, "lug" type cover. 5. 2" X 1-1/2" hex brass bushing (MIPT x FIPT. 2 each 1-1/2" brass or bronze nipples 6" length, threaded ends. 2 each 1-1/2"-90° brass or bronze elbows (FIPT x FIPT. 6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 1-1/2" soft copper tubing type K or brass nipples (MIPT x MIPT), length to fit. 8. 1-1/2" threaded brass 90° ell, for Ford L44-77 or equal. 9. 1-1/2" Customsetter with by—pass Ford: VBH 86-12B-11-66 (x 13-3/16"), McDonald Brass: 3OB612WDFF665 or Mueller B-1427-1 1/2", with flanged angle ball valve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and purity tests. 12. 17"x30" Plastic meter box equal to Mid—States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron diamond plate cover 18"x31" equal to Mid—States Plastics, Inc. MSCBC-1730—R with 2" drilled hole for touchread pit lid. 13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford C-14-66 or equal. The property owner is responsible for any necessary adaptation or extension of water service. ZY e + PUBLIC WORKS 1 %2" AND 2" WATER SERVICE LOCATED STD. PLAN — 320.2 O DEPARTMENT IN PLANTING STRIP N,yp MARCH 2010 CAUTION VALVE BOX SHOULD NOT REST ON PIPE. LATER COMPACTION IN AREA OF VALVE BOX COULD CAUSE THE BREAKAGE OF THE SERVICE. 9" MIN. 12" MAX. ONOUn CRUSHED ROCK BASE TO SUPPORT VAULT. 1-1/2" AND 2" WATER SERVICE DETAIL MATERIAL LIST FOR 2" SERVICE WITH METER LOCATED IN RIGHT—OF—WAY BEHIND SIDEWALK FRIM PRIVATE PLUMBING SHALL CONNECT HERE 2" BRASS PLUG THREADED) BY PASS NOT ALLOWED FOR IRRIGATION METERSVMrIPTxQUICKJOINT 1. 2" tapped tee on new water meter. 2. 4" long X 2" brass nipple with threaded ends (MIPT). A — A3. 2" resilient seat valve with threaded ends, square operating nut and valve nut extension if DRILL 2" DIA. HOLE FOR required (see standard detail 330.1). TOUCHREAD DEVICE 4. Two piece cast iron valve box. Standard 8" top section with regular base section, length to fit, "lug" type cover. 5. 2" brass bushing (MIPT x FIPT) 2 each 2" brass or bronze nipples 6" length, threaded ends 2 each 2"-90° brass or bronze elbows (FIPT x FIPT) 6. 2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 2" soft copper type K or brass nipples, length to fit. 8. 2" threaded brass 90' ell. 9. 2" Customsetter with by—pass Ford VBH 86-128-11-77 (17-3/16") or McDonald brass 3OB715WDFF775, with flanged angle ball valve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and purity tests. 12. 17"x30" equal to Mid—States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron damond plate cover 18"x31" equal to Mid—States Plastics, Inc. MSCBC-1730—R with 2" drilled hole for touchread pit lid, and meter read lid. 13. 2" coupling (compression x FIPT) with 2" plug (MIPT), Ford C-14-66 or equal. The property owner is responsible for any necessary adaptation or extension of water service. MATERIAL LIST FOR 1-1/2" SERVICE WITH METER LOCATED IN RIGHT—Of—WAY BEHIND SIDEWALK 1. 2" tapped tee on new water main 2. 4" long X 2" brass nipple with threaded ends (MIPT). 3. 2" resilient seat valve with threaded ends, square operating nut and valve nut extension if required see standard detail 330.1). 4. Two piece cast iron valve box. Standard 8" top section with regular base section, length to fit, lug" type cover. 5. 2" X 1-1/2" hex brass bushing (MIPT x FIPT), 2 each 1-1/2" brass or bronze nipples 6" length threaded ends), 2 each 1-1/2"— 90' brass or bronze elbows (FIPT x FIPT) 6. 1-1/2" (MIPT) x compression fitting, Ford C84-66 or equal. 7. 1-1/2" soft copper type K or brass nipples, length to fit. B. 1-1/2" pack—joint 90° ell, for Ford L44-77 or equal. 9. 1-1/2" Customsetter with by—pass Ford VBH 66-12B x 13-3/16" or McDonald brass, with flanged angle ball valve and padlock wings on inlet, and angle check valve outlet, ball valve on bypass with padlock wings. Customsetter shall have vertical inlet and outlet. 10. Rigid meter spreader to be supplied and installed in meter setter by contractor. 11. Water meter shall be supplied and installed by City of Renton upon payment of all related water meter fee and satisfactory pressure and purity tests. 12. 17"x30" equal to Mid—States Plastics, Inc. BCF Series MSBCF 1730-18 with 2" thick Ductile iron damond plate cover 18"x31" equal to Mid—States Plastics, Inc. MSCBC-1730—R with 2" drilled hole for touchread pit lid and meter read lid. 13. 1-1/2" coupling (compression x FIPT) with 1-1/2" plug (MIPT), Ford C-14-66 or equal. The property owner is responsible for any necessary adaptation or extension of water service. NOTE: ALL METER BOXES INSTALLED IN CONCRETE OR PAVED DRIVEWAYS SHALL BE CAST—IRON EQUAL TO OLYMPIC FOUNDARY. EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH SIDES OF METER BOX. TYPICAL RIB 2-1/2" MIN. FROM NEAREST AND FRONT EDGE OF PIT LID ZY e + PUBLIC WORKS 2 AND 1 12" WATER SERVICE LOCATED STD. PLAN — 320.3 O DEPARTMENT IN RIGHT OF WAY BEHIND SIDEWALK N,yp FEBRUARY 2010 12" M. 18" MF SEE A A PLAN VIE WATER SECTION A—A VALVE BOX LID WITH EARS IN DIRECTION OF 2" SQUARE WATER MAIN AND WORD OPERATING NUT WATER" CAST INTO IT CONCRETE COLLAR FOR LVES IN PAVED AREAS 4-1/4" DIA. 1/8" MIN. THICKNESS IECE CAST IRON VALVE X, RICH—SEATTLE TYPE OLYMPIC FOUNDRY 1" STEEL LENGTH AS REQUIRED 1/8" MIN. THICKNESS 2-1/4" INSIDE MEASUREMENT 2-1/4" DEPTH VALVE OPERATING NUT EXTENSION VALVE OPERATION NUT EXTENSION NOTE: EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN THREE (3) FEET BELOW 3" FINISHED GRADE. EXTENSIONS ARE TO BE A 38" MIN. MINIMUM OF ONE (1) FOOT LONG. ONLY ONE WIDTH EXTENSION TO BE USED PER VALVE. WHITE POS NOTE: ALL EXTENSIONS ARE TO BE MADE 62" OF STEEL, SIZED AS NOTED, AND PAINTED — —I WITH TWO COATS OF METAL PAINT. llllllllllll 111111_ -Ti i 24" VALVE MARKER NOTES: VALVE MARKERS SHALL BE EQUAL TO CARSONITE UTILITY MARKER VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS VALVE MARKER POST ZY Oe + PUBLIC WORKS VALVE BOX, MARKER & OPERATING STD. PLAN — 330.1 DEPARTMENT NUT EXTENSION N,yp MARCH 2010 CAP 22-1/2' BEND 45° BEND TEE 90° BEND THRUST BLOCK BEARING AREA IN SQUARE FEET (SEE NOTES) FOR HORIZONTAL AND DOWNWARD VERTICAL BENDS SOIL FIRM SILT COMPACT SANDFIRMSILTYSAND COMPACT SAND & GRAVEL 90°45° BEND 11 1/4° 90° 45` BEND 11 1/4° 90° 45° BEND 11 1/4° FITTING BEND TEE CAP OR PLUG 22 1/2° BEND TEE CAP OR PLUG & 22 1/2° BEND TEE CAP OR PLUG & 22 1/2° BEND BEND BEND 4" 7.0 4.2 1 4.2 1.7 2.9 2.1 2.1 1.0 2.2 1.6 1.6 1.0 6" 13.3 9.4 9.4 3.8 6.7 4.7 4.7 1.9 5.0 3.5 3.5 1.4 8" 23.3 16.7 16.7 6.7 11.7 8.4 8.4 3.4 8.8 6.3 6.3 2.5 12" 53.0 37.5 37.5 15.0 126.5 18.8 18.8 7.5 20.0 14.0 14.0 5.6 AREAS CALCULATED ON 300 PSI TEST PRESSURE. 3'-0" MIN. COVER FOR WATERMAIN LESS THAN 12". 4'-0" MIN. COVER FOR WATERMAIN 12" OR GREATER. MAX. HEIGHT OF THRUST BLOCK (FT) = 0.5 x DEPTH OF TRENCH MIN. HEIGHT OF THRUST BLOCK (FT) = O.D. PIPE + 1.0' TRUST BLOCK BE, REA REFERS TO 4CE OF BLOCK M IN SQUARE FEET NOTES: 1. LOCATION AND SIZE OF BLOCKING FOR PIPE LARGER THAN 12"DIAMETER AND FOR SOIL TYPES DIFFERENT THAN SHOWN SHALL BE DETERMINED BY THE ENGINEER. 2. ALL BLOCKING SHALL BE POURED IN PLACE AGAINST UNDISTURBED NATIVE GROUND. 3. ALL POURED THRUST BLOCKS SHALL BE BACKFILLED AFTER MIN. 1 DAY. PRESSURE TESTING SHALL OCCUR AFTER CONCRETE HAS REACHED NOMINAL COMPRESSIVE STRENGTH. 4. ALL BLOCKING SHALL BE CONCRETE CL 5 (1-1/7'). 5. BLOCKING AGAINST FITTINGS SHALL BEAR AGAINST THE GREATEST FITTING SURFACE AREA POSSIBLE, BUT SHALL NOT COVER OR ENCLOSE BELL ENDS, JOINT BOLTS OR GLANDS REASONABLE ACCESS TO BOLTS AND GLANDS SHALL BE PROVIDED. r+(ND CONCRETE BLOCKING FOR STD. PLAN - 330.2 PUBLIC WORKS DEPARTMENT HORIZONTAL AND DOWNWARDLl VERTICAL BENDS MARCH 2010 WATER MAIN IF ADDITIONAL ADJUSTMENT IS REQUIRED, INSTALL 2-2" CLOSE NIPPLE AND 2-2" 90° BEND, SCREWED 2" CLOSE NIPPLE AT THIS POINT. FIELD LOCATE PLASTIC METER BOX IN PLANTER OR CAST IRON BOX IN PAVED OR CONCRETE AREAS. 2" CLOSE NIPPLE 2" 2" 90• ELBOW 2" 90° ELBOW GALVANIZED PIPE AS REQUIRED CONCRETE BLOCKING IrisA\ VALVE NUT EXTENSION AS REQUIRED TWO PIECE CAST IRON VALVE (SEE DWG BR46 / PAGE B090) EQUAL TO OLYMPIC FOUNDRY CO. GROUND LINE CONCRETE SIDEWALK STANDARD 8" TOP SECTION, 6" MAX. WITH REGULAR BASE SECTION LENGTH TO FIT., 2" RESILIENT SEATED 2 1/2" NST (HOSE) GATE VALVE, SCREWED AND 2 1/2" FNST 2" GALVANIZED CAP WITH GASKET PIPE 12" LONG 2" CLOSE NIPPLE 2"x2"x2" TEE AND 2" CAP BETWEEN CAP OR PLUG _ 2" CLOSE NIPPLE BEWTEEN TEE AND 2" 90° ELBOW AND 90° ELBOW. INSTALL 4 MIL POLYETHYLENE 18" MAX. oa ooa ooa PLASTIC COVER OVER WASHED ° ° ° °°0 °° ° ° ° ° GRAVEL. CUT HOLE FOR PIPE°a° °0 oOo 0 000 00000 10 CU. FT. WASHED GRAVEL PASSING 1-1/2" AND RETAINED ON 1/4" MESH FOR DRAIN ELEVATION 2" 90° ELBOW ZY STD. PLAN — 340.1Oet + PUBLIC WORKS 2" BLOW—OFF DEPARTMENT PERMANENT ASSEMBLY N,yp MARCH 2010 f TO MF r' L_ f-'\ I N BOXES u V11114. r r«E- DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS—CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. Y s4" TO 2" DOUBLE CHECK VALVE STD. PLAN — 340.8 n + PUBLIC WORKS ASSEMBLY FOR IRRIGATION OR 1 oI DEPARTMENT RESIDENTIAL FIRE SPRINKLER MARCH 2010 w 120 VOLT ELECTRICAL OUTLET FOR z HEAT TAPE. INSTALL HEAT TAPE FOR FREEZE PROTECTION CENTER BACKFLOW ry PREVENTER IN LJ 0 o REDUCED PRESSURE ENCLOSURE Of BACKFLOW ASSEMBLY Of (RPBA) 3" MIN. o 3" MIN, INSULATED ENCLOSURE 3" MIN. "HOT BOX" OR EQUAL 3/8" X 4" ANCHOR BOLTS PER MANUFACTURER 0 3" MIN. CONCRETE SLAB z UNION FINISHED N GRADE FINISHED `V GRADE 2 a DRAIN z SEE NOTE 4 6" MINIMUM SLEEVE FREE DRAINING (TYP.) GRAVEL z CONNECT TO N WATER METER IMMEDIATELY ADJACENT TO RPBA FLOW INSTALLED W/ APP'D. TO OWNERS ELECTRICAL PANEL. FRONT VIEWMATERIALPERUPCDIRECTBURIALORINRIGIDMETERSIDESIZEASREQ.) CONDUIT PER ELECTRICAL SIDE VIEW PERMIT REQUIREMENTS. NOTES: 1. ALL REDUCED PRESSURE BACKFLOW ASSEMBLIES (RPBA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE RPBA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE RPBA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE RPBA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS—CONNECTION CONTROL SPECIALSIT, FAX NO. 425-430-7241. 4. DRAIN SHALL BE SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL MANUAL STANDARDS 3" DRAIN FOR 1" OR SMALLER RPBA's, 4" DRAIN FOR 1.5" TO 2" RPBA's, 6" FOR 3" RPBA's. 5. RPBA AND ENCLOSURE SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. ZY STD. PLAN — 350.2 e + PUBLIC WORKS REDUCED PRESSURE BACKFLOW y DEPARTMENT ASSEMBLY IN HOT BOX N,p MARCH 2010 CONCRETE BLOCKING ALL DETECTOR DOUBLE CHECK VALVE ASSEMBLIES SHALL INCLUDE RESILIENT SEATED SHUTOFF VALVES AND TEST COCKS, AND APPROVED CROSS -CONNECTION CONTROL ASSEMBLIES PER DEPARTMENT OF HEALTH LATEST APPROVED LIST. TOUCH READ PIT LID SENSOR M ON STEEL PLATE COVER THROUI DIA. DRILLED HOLE IN COVER. 6" MIN. DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM WITH CATCH BASIN OR MA COMPACTED . GRAVEL N OTE: 1. LOCATE VAULT IN PLANTING AREA NOT IN PAVING. 2. 4" AND LARGER BENDS AND TEES TO BE CAST IRON CEMENT LINED. 3. TEMPORARY SUPPORT SHALL BE PROVIDED UNDER VALVES AT THE TIME OF INSTALLATION TO CENTER THE PIPE IN VAULT OPENING. AFTER COMPLETE INSTALLATION REMOVE THE TEMPORARY SUPPORT AND INSTALL ADJUSTABLE PIPE SUPPORT. 4. GALVANIZED LADDER FOR ACCESS. 5. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPT. OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER, TEST REPORT TO BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT. PRIOR TO ACTIVATION OF NEW LINE. 6. INSTALL BRASS Y4" FLARE TEST COCKS WITH Y4" FLARE CAPS. PLAN DOUBLE CHECK VALVE ASSEMBLY INCLUDES TWO RESILIENT SEATED SHUTOFF VALVES. 4 FLANGED COUPLING ADAPTER EQUAL TO ROMAC. END VIEW THE BY-PASS ASSEMBLY SHALL BE FL. INCLUDED AS PART OF THE DETECTOR POST INDICATOR POST VALVE SAME SIZE AS DOUBLE CHECK VALVE ASSEMBLY. EQUAL), PAINTED RED. 4" DUCTILE 5/B" x 3/4" METER SHALL BE CEMENT LINED, LENGTH TO FIT. SENSUS SRII WITH TOUCHREAD PITUD TR/PL) ICE REGISTER. METER OWNED BY CITY) TOUCH READ PIT LID SENSOR 2 X 2N' FIRE DEPARTMENT SIAMESEMOUNTEDONSTEELPLATECOVERCONNECTIONFORSTANDPIPEWITH PRECAST CONCRETE VAULT WITH 2 - 3'x 3' THROUGH 2" DIA. DRILLED HOLE IN BREAKABLE CAST IRON HOSE CAPS. HINGED STEEL PLATE COVERS. DIMENSIONS 5'-0" COVER. x 9'-0" x 7'-2" UTILITY VAULT CO. 4484 -LA OR EQUAL CITY PIPING PRIVATE PIPING 4" PIPE FL.x FL. 2'-0" LONG 4" SWING TYPE GRAVITY OPERATED CHECK VALVE, FL. EQUAL TO MUELLER CO. A-2600-6 WITH BALL DRIP VALVE AT BOTTOM 4" FL. z P.E. D.I. PIPE 34„ WITH COLLAR 18" FROM 9 -0 INSTALL EPDXY NON -SHRINK GROUT (TYP.) z_ P.E. V-4" LONG 4" PIPE, FL. FL. 3b" LONG a 21" 4" SHORT RADIUS 90' BEND FL. TEE (MJ x FL) vGATE VALVE (FL x MS) 2, -10 ' 4" 90BEND FL. 2,-"6j, 5'_O" TO CITY MAIN TO BUILDING 12" ALL AROUND - - u 2'-2" .; DEADMAN BLOCK REQUIRED. CONCRETE BLOCKING ALL DETECTOR DOUBLE CHECK VALVE ASSEMBLIES SHALL INCLUDE RESILIENT SEATED SHUTOFF VALVES AND TEST COCKS, AND APPROVED CROSS -CONNECTION CONTROL ASSEMBLIES PER DEPARTMENT OF HEALTH LATEST APPROVED LIST. TOUCH READ PIT LID SENSOR M ON STEEL PLATE COVER THROUI DIA. DRILLED HOLE IN COVER. 6" MIN. DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM WITH CATCH BASIN OR MA COMPACTED . GRAVEL N OTE: 1. LOCATE VAULT IN PLANTING AREA NOT IN PAVING. 2. 4" AND LARGER BENDS AND TEES TO BE CAST IRON CEMENT LINED. 3. TEMPORARY SUPPORT SHALL BE PROVIDED UNDER VALVES AT THE TIME OF INSTALLATION TO CENTER THE PIPE IN VAULT OPENING. AFTER COMPLETE INSTALLATION REMOVE THE TEMPORARY SUPPORT AND INSTALL ADJUSTABLE PIPE SUPPORT. 4. GALVANIZED LADDER FOR ACCESS. 5. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPT. OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER, TEST REPORT TO BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT. PRIOR TO ACTIVATION OF NEW LINE. 6. INSTALL BRASS Y4" FLARE TEST COCKS WITH Y4" FLARE CAPS. PLAN DOUBLE CHECK VALVE ASSEMBLY INCLUDES TWO RESILIENT SEATED SHUTOFF VALVES. 4 FLANGED COUPLING ADAPTER EQUAL TO ROMAC. END VIEW 4" 90' BEND FL. EL LADDER EL PIPE SUPPORI, SIANCHIONS BOLTED TO FLOOR MAD PUBLIC WORKS V DDCV ASSEMBLY WITH STANDPIPE DEPARTMENT OUTSIDE CONNECTION NZ STD. PLAN — 360.1 IkI.1:Vo111W4111to] L 4"x4"x4" TEE FL. 4" GATE VALVE MJ X FL WITH INDICATOR POST INDICATOR POST VALVE SAME SIZE AS DOUBLE CHECK VALVE (MUELLER CO. OR EQUAL), PAINTED RED. 4" DUCTILE IRON CLASS 52 PIPE, CEMENT LINED, LENGTH TO FIT. 4" 90' BEND FL. EL LADDER EL PIPE SUPPORI, SIANCHIONS BOLTED TO FLOOR MAD PUBLIC WORKS V DDCV ASSEMBLY WITH STANDPIPE DEPARTMENT OUTSIDE CONNECTION NZ STD. PLAN — 360.1 IkI.1:Vo111W4111to] DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 9/11/2019 | 2:12 PM PDT PATCHED AREA A A COVER EQUALWANDADRYOS ANDRAFTER OVED P LAN PATCHING NTS 2'-0" ouTSIDE DiA. 2'-p" DEPTH OF CLASS "B" I ASPHALT TO BE 2" BELOW BOTTOM OF THE UPPER ADJUSTMENT RING OR A MINIMUM OF 8" WHICHEVER IS GREATER. i`////// ' jAjAjAjAjAjAj ° jAjAjAjAjAjAji i\///\/j\/%///j/j j/////j/jA/ A A-VA,A,,VA MORTAR JOINT(S) (3/8" MIN.) SEE ADJUSTMENT RING (1" MIN.) OR NOTE 3 AND SPECIAL PROVISON BRICKS. SEE NOTE 4. 7-05.3(1). SECTION A- A NOTES 1. REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE 3. ALL JOINTS BETWEEN THE CONE,ADJUSTMENT RINGS, WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS FOUR BRICKS AND FRAME SHALL BE GROUTED. FEET. ADJUST CASTING FRAME TO PAVEMENT SURFACE USING RISER RINGS OR CONCRETE BLOCKS PER STD.PLAN 4. ADJUSTMENT OF THE FRAME TO GRADE SHALL BE 400.1. ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS,BRICKS AND MORTAR ONLY.BRICKS SHALL BE 2. REPLACE EXCAVATED MATERIAL WITH A MINIMUM OF 8"OF STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND.THE I CLASS"B"ASPHALT OR TO A DEPTH THAT IS 2"BELOW THE USE OF SHIMS IS PROHIBITED. I BOTTOM OF THE UPPER ADJUSTMENT RING WHICHEVER IS i GREATER OR AS APPROVED BY THE ENGINEER. Y STD. PLAN — 400.4 n TYPICAL UTILITY COVER APPROVED:PUBLIC WORKS pDJUSTMENT FOR o$ DEPARTMENT ppVEMENT OR OVERLAY Zy N r eu.or.sam;o.cr.wr DATE DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 9/11/2019 | 2:12 PM PDT DocuSign Envelope ID:345B681 D-914F-4F2D-AB59-7C192D3B78A3 Meg 60" MIN. USE ROMAC COUPLING OR APPROVED EQUAL WHEN CONNECTING TO AN EXISTING SEWER MAIN l+s!'r.•.v t U I ji'i''ii''i ''ii i'ii'i''BACKFILLWITH COF TOOSPRINGLINE 7 '':.••.:y. •' i4 i''i, ;= a.-:•. CONCRETE BLOCKING NOTES: 1. OUTSIDE DROPS SHALL BE INSTALLED ONLY WHERE APPROVED BY THE CITY. 2. MANHOLE SHALL CONFORM TO ALL APPLICABLE REQUIREMENTS OF STANDARD PLAN 400.1. 3. OUTSIDE DROP SHALL BE THE SAME DIAMETER AS THE EXISTING SEWER MAIN 4. NEW DROPS THAT CONNECT TO ALL EXISTING SEWER MAIN LINE MATERIALS EXCEPT DUCTILE IRON SHALL BE PVC SDR 35. DROPS CONNECTING TO DUCTILE IRON SHALL BE AWWA C900 PIPE WITH AWWA C907 FITTINGS. 5. DROP TEE SHALL BE A MINIMUM OF 3 FEET BELOW THE CONE SECTION. 6. MANHOLE SHALL BE CORE—DRILLED FOR NEW DROP. USE KOR—N—SEAL CONNECTORS OR APPROVED EQUAL. 7. CHANNEL BASE WITH 3000 PSI CONCRETE. WIDTH AND DEPTH OF CHANNEL SHALL MATCH THE LARGEST DIAMETER PIPE. SLOPE SHELF TO CHANNEL AT 1—INCH PER FOOT MIN. 8. USE ROMAC COUPLING OR EQUAL WHEN CONNECTING TO AN EXISTING SEWER MAIN. 9. MANHOLE CONE SECTION AND ACCESS LADDER MAY NEED TO BE RELOCATED TO ALLOW DROP. STD.PLAN-402.1 PUBLIC WORKS OUTSIDE DROP CONNECTION AP y,K f DEPARTMENT FOR SANITARY MANHOLE Martin Pastucha 10/26/2020 13,0004 FD988449D... GATE DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 9/11/2019 | 2:12 PM PDT DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 9/11/2019 | 2:12 PM PDT DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 9/11/2019 | 2:12 PM PDT DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 9/11/2019 | 2:12 PM PDT 24"x 24" COMM. CLS. CONCRETE BLOCK POURED AROUND CONNECTION TO M) NOTE: DO NOT USE WITHOUT WRITTEN APPROVAL OF THE WASTEWATER UTILITY. COVER 6' BELOW STREET GRADE 6" ON 6" Y BRANCH LENGTH VARIES 11 1/8 BEND STANDARD 6" X MAIN SIZE TEE SEWER MAIN NOTE: TO RAISE TO GRADE USE STANDARD 6" SEWER PIPE Y STD. PLAN — 409 PUBLIC WORKS SIDE SEWER RISERADEPARTMENTCONNECTIONTOSEWER MAIN NTo MARCH 2008 DocuSign Envelope ID: 7CDD88BC-C843-439E-9366-C6DBB0F8BBB7 9/11/2019 | 2:12 PM PDT SHEET 1 OF 1 SHEETD/2D/215"D/2D/2D/3 9" DRILL AND GROUT WHEN WIDENING EXISTING PAVEMENT WITH PCCPLANE WIDTHPCCP TO HMA LONGITUDINAL JOINT PCCP TO PCCP LONGITUDINAL CONSTRUCTION JOINT TRANSVERSE CONTRACTION OR CONSTRUCTION JOINT (TYP.) (SEE SECTION VIEWS) LONGITUDINAL CONTRACTION OR CONSTRUCTION JOINTS (TYP.) (SEE SECTION VIEWS)LANE WIDTHLANE WIDTH15' - 0" (TYP.)1' - 0"1' - 0"LONGITUDINAL JOINT (SEE SECTION VIEW) 1' - 6"DA 12" D 15" HMA TRANSITION DETAIL A 12" D D/2 - 1" 5" 9" SLAB THICKNESS (D) CONSTRUCTION JOINT EXISTING APPROACH SLAB TRANSITION DETAIL NO DOWEL BARS REQUIRED 1.25 × D DEPTH OF PCCP (D) HMA SHOULDER IF REQUIRED HMA PCCP SHOULDER IF REQUIRED HMAEXISTING PCCP THE LAST PCCP PANEL PCCP #5 BAR ~ 18" (IN) LONG @ 12" (IN) SPACING A2' - 0" EXISTING PCCP PCCP FINISH OUTER EDGE OF PCCP SHOULDER WITH 1/2" (IN) RADIUS FINISH OUTER EDGE OF PCCP SHOULDER WITH 1/2" (IN) RADIUS TIE BAR ~ #5 BAR × 30" (IN) LONG ON 36" (IN) CENTERS TIE BAR ~ #5 BAR × 30" (IN) LONG ON 36" (IN) CENTERS APPROACH SLAB (EXISTING BEFORE CONTRACT) #5 TIE BAR ~ 30" (IN) LONG ON 36" (IN) CENTERS ~ TYPICAL ALL LANES DOWEL BARS ~ 1 1/2" (IN) DIAM. × 18" (IN) LONG ON 12" (IN) CENTERS ~ TYPICAL ALL LANES UNLESS NOTED IN THE PLANS USE ON GRANULAR BASES ONLY ~ NO TAPER REQUIRED ON ASPHALT BASES SAWED GROOVE ~ WIDTH 3/16" (IN) MIN. TO 5/16" (IN) MAX. ~ DEPTH 1" (IN) MIN. ~ SEE STANDARD SPECIFICATION, SECTION 5-04.3(12)A2 DOWEL BAR ~ 1 1/2" (IN) DIAM. × 18" (IN) LONG ON 12" (IN) CENTERS DOWEL BAR ~ 1 1/2" (IN) DIAM. × 18" (IN) LONG ON 12" (IN) CENTERS CEMENT CONCRETE PAVEMENT JOINTS 3" TO 4" 3" TO 4" D/4 MIN. TO D/3 MAX. SAWED GROOVE ~ WIDTH 3/16" (IN) MIN. TO 5/16" (IN) MAX. OVER MIDPOINT OF BAR ~ SEE STD. SPEC. SEC. 5-05.3(8)B SAWED GROOVE ~ WIDTH 3/16" (IN) MIN. TO 5/16" (IN) MAX. OVER MIDPOINT OF BAR ~ SEE STD. SPEC. SEC. 5-05.3(8)B SAWED GROOVE ~ WIDTH 3/16" (IN) MIN. TO 5/16" (IN) MAX. ~ DEPTH 1" (IN) MIN. ~ SEE STD. SPEC. SEC. 5-05.3(8)C SAWED GROOVE ~ WIDTH 3/16" (IN) MIN. TO 5/16" (IN) MAX. ~ DEPTH 1" (IN) MIN. ~ SEE STD. SPEC. SEC. 5-05.3(8)C STANDARD PLAN A-40.10-04 TRANSVERSE CONSTRUCTION JOINT SECTION VIEWSECTION VIEW TRANSVERSE CONTRACTION JOINT SECTION VIEW LONGITUDINAL CONTRACTION JOINT SECTION VIEW SECTION VIEW ELEVATION VIEW ELEVATION VIEW PLAN VIEW 1' - 0 " FACE OF CURB 1' - 0" (TYP.)4" R ISOLATION PAD USUAL JOINT TRACK LESS THAN 4' - 0"RECTANGULAR FRAME ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER 4' - 0" OR MORE FACE OF CURB RECTANGULAR FRAME 1' - 0"CIRCULAR FRAME 1' - 0"CIRCULAR FRAME PAVEMENT JOINT (TYP.) ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER 1' - 0 " USUAL JOINT TRACK CIRCULAR FRAME PAVEMENT JOINT (TYP.) ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER SHEET 1 OF 2 SHEETS PCC PAVEMENT ISOLATION JOINTS FACE OF CURB RECTANGULAR FRAME (COMBINATION INLET SHOWN)1' - 0"CIRCULAR FRAME 1' - 0"PAVEMENT JOINT (TYP.) CIRCULAR FRAME ADJUSTED PAVEMENT JOINT LESS THAN 4' - 0" 4' - 0" OR LESS 4' - 0" OR MORE 4' - 0"OR MORE4' - 0"OR LESS1' - 0 " FACE OF CURB PAVEMENT JOINT 4' - 0" OR MORE LESS THAN 4' - 0" FACE OF CURB ALL CONDITIONS ARE SHOWN IN PLAN VIEW.6' - 0" MIN.PAVEMENT JOINT PAVEMENT JOINT PAVEMENT JOINT (TYP.) PAVEMENT JOINT (TYP.) FACE OF CURB EDGE OF SHOULDER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER TIE BAR ~ # 5 BAR, 30" LONG SPACING = 6" O.C. TIE BAR ~ # 5 BAR, 30" LONG SPACING = 6" O.C. ADJUSTED PAVEMENT JOINT (TYP.) PAVEMENT JOINT USUAL JOINT TRACK (TYP.) TIE BAR ~ # 5 BAR, 30" LONG SPACING = 6" O.C. TIE BAR ~ # 5 BAR, 30" LONG SPACING = 6" O.C. CONDITION A CONDITION B CONDITION C (SHOULDER USE ONLY)CONDITION D CONDITION E CONDITION F CONDITION G CONDITION H CONDITION I CONDITION J STANDARD PLAN A-40.15-00 SHEET 2 OF 2 SHEETSSHEET 2 OF 2 SHEETS PCC PAVEMENT ISOLATION JOINTS TYPICAL ISOLATION JOINT GUIDELINES CONDITION CONTINUOUS VERTICAL FACE THROUGH THE PAVEMENT SECTION DISTANCE FROM NEAREST TRANSVERSE JOINT USE USE USE ----- ----- USE USE USE ----- ----- ----- ----- ----- ----- ----- ----- PAVEMENT JOINT (TYP.) EDGES, FLANGES OR LIPS IN THE PAVEMENT SECTION USE -----< 4 FT FROM JOINT 1 2 1 2 EDGES, FLANGES OR LIPS IN PAVEMENT SECTION ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER ISOLATION JOINT ~ 3/4" PREMOLDED JOINT FILLER CONTINUOUS VERTICAL FACE THROUGH THE PAVED SECTION CATCH BASIN OR COMBINATION GRATE CATCH BASIN OR COMBINATION GRATE GRATE INLET, CATCH BASIN OR CONCRETE INLET GRATE INLET, CATCH BASIN OR CONCRETE INLET GRATE INLET, CATCH BASIN OR CONCRETE INLET CATCH BASIN OR COMBINATION GRATE USE USE MANHOLE OR CATCH BASIN TYPE 2 MANHOLE OR CATCH BASIN TYPE 2 MANHOLE OR CATCH BASIN TYPE 2 USE -----MANHOLE OR CATCH BASIN TYPE 2 < 4 FT FROM JOINT < 4 FT FROM JOINT > 4 FT FROM JOINT > 4 FT FROM JOINT > 4 FT FROM JOINT ----- ----- PAVEMENT JOINT (TYP.) WITH RECTANGULAR GRATE CAST INTO ADJUSTMENT SECTION. DRILL A 2" DIAM. FULL-DEPTH HOLE, FILL WITH JOINT SEALER STANDARD PLAN A-40.15-00 T - JOINT DETAIL TYPICAL APPLICATIONS PLAN SECTION A SECTION B SHEET 1 OF 1 SHEET W SHOULDER 12' MIN. GUIDE OR DIRECTIONAL SIGN WITH SECONDARY SIGN INSTALLATION ON EXPRESSWAYS AND FREEWAYS SIGN INSTALLATION IN CURB SECTION SIGN INSTALLATION BEHIND TRAFFIC BARRIER MULTIPLE SIGN POST INSTALLATION IN DITCH SECTION SIGN INSTALLATION IN DITCH SECTION MULTIPLE SIGN POST INSTALLATION IN FILL SECTION SIGN INSTALLATION ON STEEP FILL SLOPES SIGN INSTALLATION IN FILL SECTION SIGN6' MIN. SLOPE BREAK V (7' MIN.) V (7' MIN.) SHOULDER W SLOPE BREAK SIGN SHOULDER SLOPE BREAK W V (7' MIN.) SIGN6' MIN. 12' MIN. SLOPE BREAK SHOULDER 12' MIN. V (8' MIN.) V (5' MIN.) MAJOR SIGN 0" MIN. 3" MAX. W V (7' MIN.) EDGE OF TRAVELED WAY EDGE OF TRAVELED WAY EDGE OF TRAVELED WAY EDGE OF TRAVELED WAY SIGN EDGE OF TRAVELED WAY CURB W 2' MIN. V (7' MIN.) SIGN 3' MIN. W TRAFFIC BARRIER EDGE OF TRAVELED WAY SIGN WITH SUPPLEMENTAL PLAQUE INSTALLATION IN FILL SECTION V (7' MIN.) SLOPE BREAK SHOULDER PRIMARY SIGN6' MIN. 12' MIN. W 0" MIN. 3" MAX. SUPPLEMENTAL PLAQUE EDGE OF TRAVELED WAY EDGE OF TRAVELED WAY SLOPE BREAK SHOULDER 12' MIN. W 4' MIN. V (7' MIN.) ` SIGN SHOULDER 12' MIN. W EDGE OF TRAVELED WAY SLOPE BREAK 4' MIN. V (7' MIN.) ` DITCH DITCH SIGN 1. BACKSLOPE 6' MIN. Refer to the Sheet SN-503 for the 'V' and 'W' distances. The minimum vertical distance from the bottom of the sign to the ground shall not be less than 7' (ft) for signs located within the Design Clear Zone. V (5' MIN.) 12' MIN. 6' MIN. 6H : 1V SLOPE OR FLATTER FILL SLOPES STEEPER THAN 6H : 1V 2. BACKSLOPE SECONDARY SIGN 7' MIN. 3' MIN. GROUND-MOUNTED SIGN PLACEMENT 7' MIN. HINGE OR NOTCH POINT 1 1 3' (FT) MIN. FROM ANY POINT ALONG BOTTOM EDGE OF SIGN PANEL TO THE GROUND NOTES STANDARD PLAN G-20.10-02 SHEET 1 OF 1 SHEET 1. 2.~~3' - 0"3' - 6"4" MAX. TOP OF SIGN POST TOP OF SIGN SIGN POST 2"VARIESVARIESFINISHED GROUND LINE 3' - 6"3' - 0"1"COMMERCIAL CONCRETE 9"STABILIZER FIN CLEAN-OUT BAR4"MAX. 9"COMPACTED NATIVE BACKFILL MATERIAL12" DIAM. COMPACTED NATIVE BACKFILL MATERIAL3' - 6"3' - 0"SIGN POST BOLT STOP FOR SIGN POST ANCHOR LEG ANGLE STABILIZER FIN WEDGE SIGN POST SIGN POST LOWER SIGN POST SUPPORT CLEAN OUT BARLOWER SIGN POST SUPPORT ~~BOLT STOP FOR SIGN POST ~~ANCHOR LEG ANGLE BOLT STOP FOR SIGN POST 9" DIAM. 12" DIAM.SEE STD. PLAN G-20.103. FINISHED GROUND LINE TOP OF LOWER SQUARE TUBE FINISHED GROUND LINE FINISHED GROUND LINE BOTTOM OF SIGN SIGN PANEL SIGN PANEL BOTTOM OF SIGN HEX BOLT WITH NUT AND WASHER (TYP.) BOLT STOP FOR SIGN POST"H1" ~ POST HEIGHT"H1" ~ POST HEIGHT"H1" ~ POST HEIGHT"H1" POST HEIGHTSIGN POST ~ 2" (IN) OR 2 1/4" (IN) SQUARE, 12-GAGE STEEL TUBE SIGN POST ~ 2 1/4" (IN) SQUARE, 12-GAGE STEEL TUBE LOWER SIGN POST SUPPORT ~ 2 1/2" (IN) SQUARE, 12-GAGE STEEL TUBE SIGN BRACE, WHEN REQUIRED ~ SEE STD. PLAN G-50.10 (SEE NOTE 2)(SEE NOTE 2)(SEE NOTE 2) SIGN POST ~ 2 1/2" (IN) SQUARE, 12-GAGE STEEL TUBE (SEE NOTE 3)(SEE NOTE 2)SEE STD. PLAN G-20.107' - 0" MIN.SEE STD. PLAN G-20.107' - 0" MIN.7' - 0" MIN.SEE STD. PLAN G-20.10 7' - 0" MIN.SIGN POST LOWER SIGN POST SUPPORT ~ 3" (IN), 7-GAGE, HOT-DIP GALV., HEAVY-DUTY ANCHOR 4. 5. TOP OF LOWER SQUARE TUBE FLANGED SHOULDER BOLT WITH NUT AND WASHERS ~ 2 REQUIRED (TYP.)1"~~SIGN POST SIGN PANEL 3/8" (IN) HEX HEAD NUT 3/8" (IN) DIAM. × 3 1/2" (IN) LONG HEX HEAD BOLT Dimensions for the parts used to assemble the base con- nections are intentionally not shown. Base connections are patented, manufactured products that are in compliance with NCHRP 350 crash test criteria. The base connection details are shown on this plan only to illustrate how the parts are assembled. For "H1", refer to the sheet SN-503. A 2" (in) post with a 2 1/4" (in) PSST anchor or a 2 1/4" (in) post with a 2 1/2" (in) PSST anchor may be substituted. See Contract Plans. NYLON WASHER 7/16" (IN) INSIDE DIAMETER (I.D.) STEEL FLAT WASHER 7/16" (IN) I.D. STEEL LOCK WASHER 2", 2 1/4" BURIEDDEPTH 2' - 6" 3' - 0" SIGN POST ~ 2" (IN), 2 1/4" (IN), OR 2 1/2" (IN) SQUARE, 12-GAGE STEEL TUBE STEEL SIGN SUPPORT TYPES ST-1 - ST-4 INSTALLATION DETAILSSEE TABLE2 1/2" Perforated square steel post shall meet the requirements of Standard Specification, Section 9-06. Use only base connection manufacturer supplied hardware that meets the requirements of Standard Specification, Sections 9-06 and 9-28. TYPE ST-4 SIGN SUPPORT ELEVATION TYPE ST-3 SIGN SUPPORT ELEVATION TYPE ST-2 SIGN SUPPORT ELEVATION TYPE ST-1 SIGN SUPPORT ELEVATION VIEW A TYPE ST-1 TYPE ST-2 TYPE ST-3 TYPE ST-4 DETAIL B NOTES STANDARD PLAN G-24.50-05 ....I ....I UJ Cl Cl :::i z 0:: UJ LL ;;.: cc I Cl 10' 30' -·1-· 10' ·1-· -l~ .. l .. l "" l ~--..,,,.~---~, --------\ YELLOW-=RLINE, CENTERLINE & LANE LINE WHITE -LANE LINE 10' l 30' 10' YELLOW NO-PASS LINE & TWO-WAY LEFT-TURN CENTERLINE 10' 10' l 30' 10' l l -~j ~: -,-:~~ . ~ -~~ --------YELLOW ~ REVERSIBLE LANE LINE l 30' l 10' l "\ I 00 t \~ITE WIDE BROKEN LANE LINE SEE CONTRACT FOR LENGTH ----------------\ YELLOW OR WHITE -SEE NOTE 2 EDGE LINE & SOLID LANE LINE NOTES 1. Dotted Extension Line shall be the same color as the line it is extending. 2. Edge Line shall be white on the right edge of traveled way, and yellow on the left edge of traveled way (on one-way roadways). Solid Lane Line shall be white. 3. The distance between the lines of the Double Centerline shall be 12" everywhere, except 4" for left-turn channelization and narrow roadways with lane widths of 10 feet or less. Local Agencies (on non-state routes) may specify a 4" distance for all locations. The distance between the lines of the Double Lane Line shall be 4". I SEE CONTRACT FOR LENGTH DOUBLE CENTERLINE & DOUBLE LANE LINE SEE CONTRACT FOR LENGTH YELLOW -DBL. CENTERLINE, WHITE -DBL. LANE LINE ~~I _________ :-s __ \ WHITE WIDE EDGE LINE & WIDE SOLID LANE LINE OPTION TO USE AS Cl RC ULA TORY ON ROUNDABOUT APPLICATIONS 1· SEE CONTRACT FOR LENGTH .c ~tc DOUBLE WIDE LANE LINE WHITE SEE CONTRACT FOR LENGTH Cl~ ____ \ ___ \ YELLOW BARRIER CENTERLINE V--()./v-,<.__ Sep 23 2020 3:46 PM ~ t 1. / / / Walsh, Brian LONGITUDINAL MARKING PATTERNS STANDARD PLAN M-20.10-03 SHEET 1 OF 2 SHEETS APPROVED FOR PUBLICATION ~~=,,-----STATE DESIGN ENGINEER .... VI Washington State Department of Transportation (EXI   ....I ....I w 0 0 :::i z 0:: w LL .. l 3' l 9' l 3' l 9' l 3' l "'" t \Mil~;: I ~ DOTTED LANE LINE ··fl 6• fl 6• fl··. YELLOW OR IM<ITE -' = _____ c=J_~~ SEE NOTE 1 DOTTED EXTENSION LINE Roundabout Specific Lines 3' -O" 2' O" 3' -O" "'l l -l l" ~I ~I ~~==::f-12·· WIDE DOTTED ENTRY LINE WHITE l 4' -O" l 3' -O" l 4' -O" l 3' -O" .. .. l 3' l 9' l 3' l 9' l 3' l 9' l 3' l 9' l3'l~ ~-= WIDE DOTTED LANE LINE 6' -O" 6' -O" 6' -O" 6'-O" 6' -O" ·· ·_· -·1-· _·_· _·_· -·1-· -r · ~ l __ s" WIDE DOTTED EXTE_N_S-IO_N_LI_N_E____________ ~ WHITE .. ·1_· 6-· l 3 ·1_· 6-· l 3' l 60 l" ___:_____J__ ----~ J~WORIM<ITE STRONG LANE LINE -SEE NOTE 1 OPTION TO USE AS CIRCULATORY ON ROUNDABOUT APPLICATIONS l 4' -O" l .. 8" p' t 1. / / / Walsh, Brian V.--{)/v-,c._ Sep 23 2020 3:50 PM LONGITUDINAL MARKING PATTERNS STANDARD PLAN M-20.10-03 SHEET 2 OF 2 SHEETS APPROVED FOR PUBLICATION ~~,-----STATE DESIGN ENGINEER ... WIDE DOTTED CIRCULATING LANE LINE WHITE VI Washington State Department of Transportation (EXI