Loading...
HomeMy WebLinkAboutR-4214299FIN GRADE RESTORE SURFACE TO ORIG OR BETTER 1 I UNDISTURBED SOIL OR 1 COMPACTED NATIVE J SOIL OR STRUCT FILL IF 4" - 6" QUARRY SPALLS 4" SCHED 40 PERFORATED PVC PIPE FOR WALLS HIGHER THAN 3'-0" V MINUS WASHED ROCK FILTER FABRIC & DRAIN PIPE FOR WALLS HIGHER THAN T-O" (2) #5 UNDISTURBED SOIL (5) #5 #4 @ 12" W/ 3" COVER WALL LAYOUT LINE 3/4" CHAMFER FOR ALL EXPOSED EDGES #4 @ 12" EW W/ 2" COVER, SEE 4/D106 FOR REBARS AT ALL CORNERS REINF BARS CONT BTWN WALL OR CURB & FTG OR SIDEWALK, DOWELLING WALL OR CURB TO FTG SHALL NOT BE ACCEPTABLE 69q��0]1� SIDEWALK OR SIDEWALK EXTENSION PER CITY STD DETAIL BEYOND THE THICKENED EDGE SHOWN CIP CONC WALL COMBINED RETAINING WALL - SIDEWALK SECTION rid SCALE: NTS 1R1.01,1R1.06,1R1.07 SEE SITE PLAN FOR LOCATION OF CONDUIT 2% REBAR OVERLAPPING -�9N LENGTH 2'-0" #4 REBAR @ 12" OC EW (TYP TO SIDEWALLS) ALTERNATE BARS SIDEWALL EXISTING GRADE J STRUCTURAL FILL J 1" MINUS WASHED ROCK 4" 0 PERFORATED PIPE, SEE PLANS FOR DAYLIGHTING REQUIREMENTS FILTER FABRIC #4 REBAR @ 12" OC EW (TYP TO SIDEWALLS ALTERNATE BARS — WALL LAYOUT LINE PEDESTRIAN GUARDRAIL TYPE 1 & SHELTER LEG TOP OF WALL = BK OF SIDEWALK 2"z4" KEY c v z O z x ¢ w EXISTING GROUND w x w w (VARIES) J N ¢ 3 w w I lee 9„ 8„ 9„ 2) #4 2'-2"MIN WALL LAYOUT LINE & SHELTER LEG 1 2141 SEE SITE PLAN FOR #4 9 —@ 12" OC LOCATION OF CONDUIT ALIGNED W VERT REINF 2 REBAR OVERLAPPING 2X4 KEY CONT @ OF WALL CK CONIC NING WALL 2" OC VERT 4" TO BAR CI OC HORIZ � @12"OC W ELS 2X4 KEY (2) #5 — a� .' {, _3 M J (2) #5 TOP RETAI z Y O -v #5@1 _ ¢ w #4@8 w x w w J N 3 w —STRUCTURAL — STRUCTURAL FILL — 4" TO 6" QUARRY $PALLS 1" MINUS WASHED ROCK 4" 0 PERFORATED PIPE, SEE PLANS FOR DAYLIGHTING REQUIREMENTS —FILTER FABRIC #5 @ 10" CIP CONC WALL COUNTERFORT WALL WITH INTEGRATED SHELTER FOOTING SECTION %B1 SCALE: NITS 1R1.02 NOTE: IF WALUFTG NOT CONSTRUCTED MONOLITHICALLY, ROUGHEN TOP SURFACE OF SLAB UNDER WALL. CLEAN AND COAT WITH CONIC EPDXY BONDING COMPOUND OR PRODUCE A 1" D X 4" W CONTINUOUS KEYWAY. CIP CONC WALL COMBINED OVER 2'-0" HIGH FILL WALL - FOOTING/FOUNDATION SECTION �1 SCALE: NITS 1R1.04E1 R1.05 60% SUBMITTAL Jacobs No REv61pN BY I APED I -ATE ,p+ oeM Dc�f DRAWN D. ARRANTS CHECKED X.wu TONAL g�0 CHECKED METRO PROJECT ENGINEER TO WALL 3" ABOVE FIN GRADE RESTORE SURFACE TO ORIG OR BETTER UNDISTURBED SOIL OR COMPACTED NATIVE SOIL OR STRUCT FILL IF 4" - 6" QUARRY SPALLS 4" SCHED 40 PERFORATED PVC PIPE FOR WALLS HIGHER THAN T-0" 1" MINUS WASHED ROCK FILTER FABRIC & DRAIN PIPE FOR WALLS HIGHER THAN 3'-0" (2) #5 UNDISTURBED SOIL (5) #5 #4 @ 12" W/ 3" COVER WALL LAYOUT LINE 3/4" CHAMFER FOR ALL EXPOSED EDGES #4 @ 12" EW W/ 2" COVER, SEE 4/D106 FOR REBARS AT ALL CORNERS REINF BARS CONT BTWN WALL OR CURB & FTG OR SIDEWALK, DOWELLING WALL OR CURB TO FTG SHALL NOT BE ACCEPTABLE SEE NOTE SEE SITE PLAN AND DWG D101 TO D103 FOR SHELTER FOOTING DETAILS. ELECTRICAL CONDUIT CIP CONC WALL COMBINED RETAININ WALL - 2'-011 SHELTER FOOTING SECTION �C1 SCALE: NTS 1111.0311 R1.07 P. ENG King County METRO PRWECTNO: EW566E18 00558E �� METRO TRANSIT CAPITAL DIVISION RAPIDRIDE I LINE RENTON SEGMENT RETAINING WALL DETAILS NOVEMBER 2021 DRAWING NO 1 R2.01 SHETNO: OE 299 XXXX R-4214299