HomeMy WebLinkAboutR-4214368CONSTRUCTION NOTES
OCONSTRUCT FOUNDATION PER SIGNAL STANDARD DETAIL CHART 1TS1.06D AND
WSDOT STD. PLAN J-26.10. TOP OF FOUNDATION SHALL BE FLUSH WITH GRADE.
FURNISH AND INSTALL TYPE III SIGNAL POLE WITH 45' MAST ARM AND 12' LUMINAIRE
ARM. FURNISH AND INSTALL FOUR 3-SECTION SIGNAL HEADS, TWO EMERGENCY
PRE-EMPTION DETECTORS AND ONE VIDEO DETECTION CAMERA ON THE MAST
ARM. REMOVE AND RELOCATE ONE D3-103 SIGN FROM EXISTING MAST ARM TO NEW
MAST ARM. FURNISH AND INSTALL TERMINAL CABINET ON SIGNAL POLE. FURNISH
AND INSTALL ONE ROADWAY, TYPE III 224W LED LUMINAIRE ON 12' LUMINAIRE ARM.
1A FURNISH AND INSTALL TYPE PS SIGNAL STANDARD PER WSDOT STANDARD PLAN
J-20.11 AND DETAIL 1T$1.06D. FURNISH AND INSTALL TWO PEDESTRIAN SIGNAL
HEADS AND TWO APB PEDESTRIAN PUSH BUTTONS WITH SIGNS ON SIGNAL POLE.
OFURNISH AND INSTALL ONE 3-SECTION SIGNAL HEAD WITH SPECIAL "BUS ONLY"
SIGN AND ONE R3-1 BLANK -OUT SIGN TO EXISTING MAST ARM. MOUNT HEAD AND
SIGN USING "ASTRO-BRAC" OR SIMILAR CABLE MOUNTED BRACKET AND CLAMP.
FIELD -DRILL A HOLE IN THE MAST ARM FROM CABLE ROUTING AND COAT EXPOSED
STEEL WITH ZINC -RICH PAINT, RELOCATE EXISTING SIGNAL HEADS AND EQUIPMENT
PER 1TS1.06D. PROTECT EXISTING TYPE III SIGNAL STANDARD, FOUNDATION AND
ASSOCIATED EQUIPMENT IN PLACE UNLESS OTHERWISE SPECIFIED.
2A FURNISH AND INSTALL TWO APB PEDESTRIAN PUSH BUTTONS WITH SIGNS ON
SIGNAL POLE. REMOVE EXISTING PEDESTRIAN PUSH BUTTONS FROM EXISTING
TYPE PS SIGNAL STANDARD. PROTECT EXISTING TYPE PS SIGNAL STANDARD,
FOUNDATION AND ASSOCIATED EQUIPMENT IN PLACE UNLESS OTHERWISE
SPECIFIED.
n
V32
V83
V84
OCONSTRUCT FOUNDATION PER SIGNAL STANDARD DETAIL CHART 1TS1.06D AND
WSDOT STD. PLAN J-26.10. TOP OF FOUNDATION SHALL BE FLUSH WITH GRADE.
FURNISH AND INSTALL TYPE III SIGNAL POLE WITH 50' MAST ARM AND 12' LUMINAIRE
ARM. FURNISH AND INSTALL THREE 3-SECTION SIGNAL HEADS AND ONE VIDEO
DETECTION CAMERA ON THE MAST ARM. REMOVE AND RELOCATE ONE D3-103 SIGN
FROM EXISTING MAST ARM TO NEW MAST ARM. FURNISH AND INSTALL TERMINAL
CABINET ON SIGNAL POLE. FURNISH AND INSTALL ONE ROADWAY, TYPE III 224W LED
LUMINAIRE ON 1Z LUMINAIRE ARM.
3A FURNISH AND INSTALL TYPE PS SIGNAL STANDARD PER WSDOT STANDARD PLAN
J-20.11 AND DETAIL 1TS1.06D. FURNISH AND INSTALL TWO PEDESTRIAN SIGNAL
HEADS AND TWO APB PEDESTRIAN PUSH BUTTONS WITH SIGNS ON SIGNAL POLE.
O4 PROTECT EXISTING TYPE III SIGNAL STANDARD, FOUNDATION AND ASSOCIATED
EQUIPMENT IN PLACE.
4A FURNISH AND INSTALL TYPE PPS SIGNAL STANDARD PER WSDOT STANDARD PLAN
J-20.11 AND DETAIL 1TS1.06D. FURNISH AND INSTALL ONE APS PEDESTRIAN PUSH
BUTTON WITH SIGN ON SIGNAL POLE.
48 FURNISH AND INSTALL TYPE PPS SIGNAL STANDARD PER WSDOT STANDARD PLAN
J-20.11 AND DETAIL 1TS1.06D. FURNISH AND INSTALL ONE APS PEDESTRIAN PUSH
BUTTON WITH SIGN ON SIGNAL POLE.
No
60% SUBMITTAL
REVIiIOv
V29 V2 V2 V53 I
V26 V25 V2 y52 I
0
� I
t*lil LiliiiiLll7nI
s mi
1
ADVANCED VIDEO DETECTION PLACEMENT
VIDEO ZONE
OFFSET FROM STOP BAR
V92
35'
V73, V74, V43, V44, V93
180,
V75, V76, V45, V46, V94
275'
V52, V24, V25, V26
180,
V53, V27, V28, V29
275'
V32, V83, V84
105,
V12, V63, V64, V65
180,
V66, V67, V68
275'
r
r
T
T
P
7
"•� L
10+00
i
Ila n31
I._ _ `D�SD�SD SD
_
c E
•
II II II II 'III "I II II II �' ;I ��� • '; ��- �.--����,Y�Ir�ati�llivl- -�-�_- _--_
E
N'All
I�y • -
DIE
Flk , I�' •�
I�
.:I%VIH��ii
I
V �d3
I'
PA_'
0
BY I APPD I DATE
.;acobs
r/z
FURNISH AND INSTALLA NEW TYPE 8 JUNCTION BOX PER WSDOT STD. PLAN J-00.30.
PRIOR TO THE REMOVAL OF EXISTING CABINET FOUNDATIONS, CONSTRUCT JOINT
CONTROLLER/SERVICE CABINET FOUNDATION PER CITY OF RENTON STANDARD
PLANS 126.1 AND 126.2. INSTALL ALL RELOCATED CONTROLLER EQUIPMENTAND
/ CONNECT FIELD WIRING. VERIFY FINAL LOCATION WITH THE ENGINEER IN THE FIELD
PRIOR TO POURING THE FOUNDATION.
OREMOVE EXISTING SIGNAL POLE AND EQUIPMENT. REMOVE FOUNDATION IN ITS
ENTIRETY AND BACKFILL VOID. REMOVE AND SALVAGE ALL SIGNAL EQUIPMENT AND
ASSOCIATED WIRING AND CONDUITS. REMOVE AND RELOCATE EXISTING SIGNS
AND PEDESTRIAN SIGNAL HEADS TO NEW POLE$. RETURN ALL SIGNAL EQUIPMENT
IN ITS EXISTING CONDITION TO THE CITY OF RENTON UNLESS OTHERWISE NOTED.
OABANDON EX. VEHICLE DETECTION LOOPS ON THE EAST LEG OF THE INTERSECTION
PER WSDOT SPECIFICATIONS AND REMOVE ALL ASSOCIATED WIRING UNLESS
OTHERWISE NOTED.
OREMOVE EXISTING CABINET FOUNDATIONS. REMOVE AND RELOCATE EXISTING
CONTROLLER CABINETS AND ALL ASSOCIATED EQUIPMENT. REMOVE AND SALVAGE
ALL WIRING AND CONDUIT.
10 REMOVE EXISTING JUNCTION BOXES, CONDUIT ELBOWS AND ALL ASSOCIATED
WIRING AND CONDUITS. BACKFILL VOID.
11 INTERCEPT EXISTING CONDUIT AND EXTEND TO NEW JUNCTION BOX.
DESicNED. APPROKED:
J.DAMS P. ENG
H/
Q4R�,0 ,y�Tay�� RA JD
J. DAMS LIM King County
CHECKED PROJECTING: RRD,EDTND
M.GSEGMETRO
�O�`isYO/ 1 R�G CHECKED CONTRACTING
ONAL
METRO PROJECT ENGINEER CXX%RRRRX
12 PROGRAM CONTROLLER SO THAT DETECTION ZONES V91 AND V92 MUST BOTH
RECEIVE A CALL SIMULTANEOUSLY TO ACTIVATE QUEUE JUMP PHASE 9 AND 10.
0' 20' 40'
SCALE:
�
METRO TRANSIT CAPITAL DIVISION
RAPIDRIDE I LINE
RENTON SEGMENT
DETECTION PLAN
S GRADY WAY & TALBOT RD S
NOVEMBER 2021
1 TS 1.06B
SHEETND OF
368 XXXX
T-421468
R-4214368