GENERAL SITE RESOTRATION NOTES
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE MEASURED TO THE BACK OF CURB.
2. PROTECT EXISTING UTILITIES AND FEATURES WITHIN PROJECT LIMITS UNLESS NOTED OTHERWISE.
3. REMOVE SIDEWALK AND CURB AND GUTTER TO NEAREST JOINT.
4. FOR SIGN REMOVALS, SEE SIGNING AND STRIPING PLANS.
5. FOR DRAINAGE REMOVALS, SEE DRAINAGE PLANS.
6. FOR UTILITY REMOVALS, SEE UTILITY PLANS.
7. FOR SIGNAL REMOVALS, SEE SIGNAL PLANS.
8. FOR LIGHTING REMOVALS, SEE LIGHTING PLANS.
9. FOR ELECTRICAL REMOVALS, SEE ELECTRICAL PLANS.
10. CHANNELIZATION REMOVALS OUTSIDE OF SAWCUT LIMITS ARE SHOWN ON THE SITE PREPARATION PLANS. CHANNELIZATION WITHIN SAWCUT LIMITS ARE ASSUMED TO BE INCLUDED WITH PAVEMENT REMOVALS.
WORK IN RIGHT-OF-WAY AND WITHIN PRIVATE PROPERTY EASEMENTS
1. WHEN THE WORK SITE IS UNATTENDED, INSTALL A SIGN WITH MINIMUM TWO-INCH LETTERS STATING PERMITTEE OR COMPANY NAME, AND DAY AND EVENING PHONE NUMBERS.
2. INSTALL BARRICADES, SIGNS, WARNING LIGHTS, AND SAFETY DEVICES SUFFICIENT TO NOTIFY PUBLIC OF OBSTRUCTIONS OR TRAFFIC HAZARDS. DEVICES MUST REMAIN UNTILTHE OBSTRUCTIONS OR TRAFFIC
HAZARDS ARE CLEARED.
3. MAINTAIN ACCESS TO FIRE STATIONS, FIRE HYDRANTS, FIRE ESCAPE$, AND FIRE FIGHTING EQUIPMENT.
4, MAINTAIN ACCESS TO PROPERTY AND BUSINESSES ADJOINING THE SITES OF WORK. FURNISH, INSTALL AND MAINTAIN TEMPORARY "BUSINESSES ARE OPEN" SIGNS AT LOCATION DESIGNATED BY THE PROJECT
REPRESENTATIVE. REMOVE UPON COMPLETION OF WORK.
5. PRESERVE AND PROTECT ALL PROPERTIES ADJOINING THE SITES OF WORK.
6. RESTORE AREAS DISTURBED BY THE WORK TO ORIGINAL OR BETTER CONDITION. REPAIR OR REPLACE DAMAGED ITEMS AS DIRECTED BY AND TO THE SATISFACTION OF THE PROJECT REPRESENTATIVE.
7. DO NOT DISTURB SURVEY MONUMENTS AND MARKERS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE CITY HAVING JURISDICTION AND FROM THE PROJECT REPRESENTATIVE. REPLACEMENT OR RESETTING
OF DISTURBED MONUMENTS AND MARKERS SHALL BE BY A WASHINGTON STATE LICENSED LAND SURVEYOR.
8. INSTALL TEMPORARY ADA-COMPLIANT SIDEWALK OR CURB RAMPS IF PERMANENT RAMPS OR ADA PATHS ARE BLOCKED. IF IT IS INFEASIBLE TO PROVIDE TEMPORARY SIDEWALKIRAMPS, PROVIDE APPROPRIATE
ACCESS DETOURS, WITH THE CORRESPONDING SIGNAGE AND AT LOCATIONS APPROVED BY THE PROJECT REPRESENTATIVE.
9. COVER OPEN EXCAVATION WITH NONSKID STEEL PLATES RAMPED TO ELEVATION OF CONTIGUOUS SURFACES.
10. MATERIAL STOCKPILING AT THE SITES OF WORK SHALL BE MAINTAINED TO A MINIMUM AND ONLY AS APPROVED BY CITY INSPECTORS, AFFECTED PROPERTY OWNERS AND THE PROJECT REPRESENTATIVE.
MATERIALS SHALL BE STORED AS NECESSARY TO PROTECT THE PUBLIC.
11. WHERE TRAFFIC LANES AND SIDEWALK CLOSURES ARE REQUIRED, IMPLEMENT THEM AS NECESSARY TO MINIMIZE PUBLIC IMPACT AND IN STRICT CONFORMANCE WITH THE CORRESPONDING, AGENCY -APPROVED,
TRAFFIC CONTROL PLANS.
12, UNLESS INDICATED OTHERWISE IN THE CONDITIONS OF THE CORRESPONDING PERMITS, COMPLETE CONCRETE AND OTHER SURFACING OR RESURFACING WORK UNDER THE FOLLOWING SCHEDULE:
A. IN PRINCIPAL ARTERIALS AND MAJOR COLLECTOR STREETS: WITHIN 3 CALENDAR DAYS.
B. IN OTHER STREETS: WITHIN 7 CALENDAR DAYS.
DEMOLITION NOTES
I. CALL 811 "CALL BEFORE YOU DIG" FOR LOCATING UNDERGROUND UTILITIES AT LEAST 48 HOURS PRIOR TO BEGINNING SITE WORK.
2. AT LEAST FIVE (5) WORKING DAYS PRIOR TO MOBILIZATION AND CLOSING OF ANY BUS STOP, CONTACT METRO TRANSIT CONSTRUCTION COORDINATOR AT (206) 477-1140 TO COORDINATE POSTING RIDER ALERT
ABOUT BUS STOP CLOSURE AND ESTABLISHMENT OF INTERIM BUS ZONES.
3. WHEN ENCOUNTERING CONSTRUCTION SITES WITH EXISTING TRANSIT FURNITURE SUCH AS SHELTERS, PEDESTRIAN LIGHT POST AND LUMINARIES, BENCHES, LITTER RECEPTABLES AND BUS STOP SIGNS AND
POSTS EXIST, CALL MATT RAWSON (206-263-%81) OF TRANSIT SOUTH FACILITIES AT LEAST 72 HOURS PRIOR TO MOBILIZATION SO THEY CAN HAVE THE FURNITURE AND FIXTURES REMOVED AND SALVAGED TO
METRO TRANSIT.
4, AT LEAST 72 HOURS PRIOR TO BEGINNING CONSTRUCTION AT A SITE OF WORK, CONTACT DOUG MUSSELMAN-BROWN OF SEATTLE TIMES AT (206) 423-4394 OR EMAIL DMBROWN@SEATTLETIMES.COM TO HAVE
NEWSPAPER BOXES REMOVED FROM THE SITE.
5. REMOVE DEMOLITION DEBRIS FROM THE WORK SITES AT THE END OF EACH DAY AND DISPOSE OF IT AT LEGALLY APPROVED SITES.
6. UNLESS OTHERWISE SPECIFIED ON THE SITE PLANS, EXISTING PEDESTRIAN LIGHT POLE FOUNDATIONS DESIGNATED TO BE REMOVED SHALL BE TAKEN OUT ENTIRELY. ELECTRICAL CONNECTORS SHALL BE
REMOVED FROM THE CONDUITS FROM HAND -HOLE TO THE EXISTING FOUNDATION. IF THE CONDUIT IS EXPOSED, REMOVE IT FROM FOUNDATION TO THE HANDHOLE, OTHERWISE CAP OR PLUG AND ABANDON IN
PLACE. PLUG CONDUIT HOLE AT HAND -HOLE. IF SPECIFIED ON THE SITE PLANS FOR AN ELECTRICAL HANDHOLE TO BE REMOVED, DE -ENERGIZE AND REMOVE ELECTRICAL CONDUCTORS ALL THE WAY TO THE
SOURCE, ABANDON THE CONDUIT IN PLACE AND CAP ITS ENDS WITH EPDXY. THEN, REMOVE THE HANDHOLE AND RESTORE SITE TO MATCH EXISTING.
7. SAWCUT PAVEMENT TO BE REMOVED TO STRAIGHT VERTICAL LINES. SIDEWALK PANELS SHALL BE REMOVED TO THE NEAREST SCORE -LINES OR CONSTRUCTION JOINTS. FIELD -VERIFY LOCATION OF SCORE -LINES
AND CONSTRUCTION JOINTS.
SITE RESTORATION NOTES
1. UNLESS SPECIFIED OTHERWISE, RESTORE SITE TO MATCH EXISTING CONDITIONS WHERE FOUNDATIONS OF SHELTERS, PEDESTRIAN LIGHT POSTS AND OTHER SITE FURNITURE ARE REMOVED. FILL EXCAVATED
AREAS WITH STRUCTURAL FILL AND COMPACT TO 95 PERCENT OF PROCTOR DENSITY. RESTORATION WORK SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO LAWN BY SODDING; SURFACING WITH MATCHING
BEAUTY BARKS; AND SIDEWALK/PATHWAY REPAIRS THAT MATCH EXISTING MATERIALS, COLOR, AND TEXTURE.
2. REFER TO CORRESPONDING ELECTRICAL SITE PLANS FOR ELECTRICAL WORK, INCLUDING CONDUIT RUNS, POWER PEDESTAL FOUNDATION AND DETAILS; CONDUIT ENTRY POINTS AT SHELTER/TECH PYLON
FOUNDATIONS, AND PEDESTRIAN LEVEL LUMINARIES; AND CONNECTION POINTS TO POWER SOURCE. RESTORE TO MATCH EXISTING ASPHALT PAVEMENT, LANDSCAPED AREAS, AND CONCRETE SIDEWALK OVER
TRENCHES EXCAVATED FOR ELECTRICAL WORK.
3. PRIOR TO WORKING ON EXISTING SPRINKLER IRRIGATION SYSTEMS, TEST IN THE PRESENCE OF THE PROJECT REPRESENTATIVE AND RECORD THE SYSTEM CONDITION. UPON COMPLETION OF THE CONTRACT
WORK, TEST AGAIN TO SATISFY THE PROJECT REPRESENTATIVE THAT THE CONDITION OF THE SYSTEM MEETS THE REQUIREMENT OF THIS CONTRACT.
4. FOOTINGS SHALL BE PLACED TO ENSURE THE SHELTER IS A MINIMUM THREE FEET FROM FACE OF CURB TO THE VERTICAL STRUCTURE; WHICH INCLUDES CANTILEVER OVERHANG AND EDGE OF THE SHELTER IF
PLACED REVERSE TO CURB.
TREE PROTECTION NOTES
1. WORK WITHIN THE TPZ SHALL BE PERFORMED IN ACCORDANCE WITH THE TEMPORARY TREE PROTECTION SPECIFICATIONS AND THE APPROVED PROTECTED TREE& PLANT MAINTENANCE PLAN.
60% SUBMITTAL va�.Obs qg� DRAM P. ENG
�� p DIUWN: ,
rp L9 King County
b m c. WILCOX
CHECKE
PROUECT
S. FOR °� EW566END: METRO
Y
Np1
p.�a prgtyg4p0� S. FORMPN E00588E18
No R-, WK N BY AFRO DATE BAONAI. CHECKED CONTRACTNO
METRO PROJECT ENGINEER CXXXXXXXX
METRO TRANSIT CAPITAL DIVISION
RAPIDRIDE I LINE
RENTON SEGMENT
SITE PREPARATION
GENERAL NOTES
NOVEMBER 2021
DMWING NO'.
NC4•00 EETN
89 XXXX
R-421489