HomeMy WebLinkAboutW-421407S
91
PHOTO ENpO
�F(NFOCR it RMx Ii°EO
PMkINO IE(Nly)a22 B. 11 12, RCP
O� S RENiON SUMP 2aP 1
P&q
RANsIr
❑ OHP 0
0 p
DO1°. OHP p_ _
O
SOCK
IF(5
I RIMa zW°
2039 "
rOP
POST
F SEOx lO.OI0
23 .
�P
P
W
IIIII
L0
C°NC
W
W
28
TO BE RELOCATED E
O
O
D
-
cD
W
Z
J
fNFp�N,EO Y@LD
6 ..a.
ASPH
PARKING
S f(W)II RIMa25
/E 1E(N)a2j. l' 6 69
OE 23 10,
0'
top 2J.g6 IrRCp
GOCB Or
Seo o RCP
/e(S rl N14a 235'
/E(NE)4>' 2p02'
a2
' 6' KC —
G
L
D�
i L
soc
lE(sw TI qIM
SUMP�i�2>' 25.>0,
6' I RCP
P—
IE(S)82It PMW
top OP? I' 6 2563.
SEOa 'RCP
�S 239,
lE(N& rI PoM
top O<.I. 725
F i I. g.RCP6>
RCP
Oa
50.
SC
le(NB ry RIM-
-SEE PROFILE A ON 660'
SHEET UP01 Q6P _
BE
BRUSH
G
G G G
SPH
PARKING
GENERAL
NOTES
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN FEET.
2. FOR STORMWATER IMPROVEMENTS SEE GRADING AND DRAINAGE
PLANS.
3. WHERE FRANCHISE UTILITIES ARE TO BE ADJUSTED, REMOVED, OR
RELOCATED, WORK SHOULD BE COORDINATED WITH EACH UTILITY.
UTILITY
NOTES
OREMOVE EXISTING HYDRANT OR STAND PIPE
O2 REMOVE EXISTING METER
OADJUST EXISTING VAULT
O4 INSTALL WATER METER
OINSTALL HYDRANT ASSEMBLY
I&RR
O6 ADJUST EXISTING METER
soMNOCUN R
top sr`wu soMH
O ADJUST EXISTING VALVE BOX
PiP[SNKNOWN2B >l
e(E)azj rNI5/BLEE S0
SOC9 If(SElaProEaz
IE(N)aS N,
RlM1.
20 ADJUST EXISTING HANDHOLE OR MANHOLE
IE(E)a23 az> Aro
(w)az I ErOp
suMPx2sWP \
S0 5u' 36, C orz
21 REMOVE EXISTING VAULT
P
r
O
. • •
Q • �..
r
O REMOVE UTILITY POLE (BY PSE)
ROW
_ , ,
I
23 RELOCATE UTILITY POLE (BY PSE)
RELOCATE EXISTING VAULT
v
c
LJ
2
0RELOCATE EXISTING JUNCTION BOX OR SERVICE CABINET
W W T
(n
26 RELOCATE HANDHOLE OR MANHOLE
w
®
P
P
0HP �OHP
—
LEJ
SO
27 UNDERGROUND ELECTRICAL SERVICE (BY PSE)
TO BE RELOCATED
2
(n
BY OTHERS
28 UNDERGROUND TELECOM SERVICE
OHP
)THERS �0
TO BE RELOCATED BY OTHERS
OHP—
25 TO BE RELOCATED BY OTHERS
(
B
O
O UNDERGROUND GAS SERVICE
�4g+00 _ 0 P
_
-dHp—
+
O INSTALL 463-LA SERVICE VAULT
—
OHP
oHP
0'40
ADJUST GAS VALVE (BY PSE)
HP
_
�
O PROTECT EXISTING FEATURE IN PLACE
—
50
it gp—
W
—
J
LEGEND
GO
EB
EXISTING WATER METER
vrtt eRusH
_ 9•
—
C)
0
EXISTING WATER METER
P
— W —
EXISTING WATER LINE
T p soce
— 5 —
EXISTING SEWER LINE
. 'Sl°P
°pNOF \Stop
o9®MWEL
s o�
— G —
EXISTING GAS LINE
IIOUNOEO
CURB
F2
EXISTING FIRE HYDRANT
X
V°.
m
EXISTING GATE VALVE
(I
MONITORING WELL
I
N
GATE VALVE
)A
FIRE HYDRANT
■
WATER METER
THRUSTBLOCK
/ • RECOMMENDED POTHOLE LDCATION
RECOMMENDED POTHOLE �(
1
2TELELINE
0' 0' 20' 4
3WATER LINE
SERVICE
5STO
5STORM DRAIN
6SANITARY SEWER LINE SCALE: 1"=40'
60% SUBMITTAL
'
Jacobs
�W
PENG..
King County
METRO
METRO TRANSIT CAPITAL DIVISION
RAPIDRIDE 1 LINE
RENTON SEGMENT
UTILITY PLAN
GRA 14+00 TO GRA 19+00
mNOVEMBER 2021
xm
CHECKED
PRwE HY
UNBEE,B
DIAMNGNO:
1 UT.06
NO.
RE`, SION
BY
APP'D
DATE
CHECKED:
METROPROJECTENGINEER
CONTRACTNO.
COCCODX%
EREEr Nn OF
269 XXXX
W-421407
S-421407