HomeMy WebLinkAboutEX_02_ERC_Report_Exhibits_Sig_Sheet_38th_Street_Short_Plat_190621
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
SIGNATURES:
Gregg Zimmerman, Administrator
Public Works Department
Date Rick M. Marshall, Administrator
Renton Regional Fire Authority
Date
Kelly Beymer, Administrator
Community Services Department
Date C.E. Vincent, Administrator Date
Department Of Community & Economic Development
ENVIRONMENTAL (SEPA) DETERMINATION OF
NON-SIGNIFICANCE - MITIGATED (DNS-M)
PROJECT NUMBER: LUA18-000683, SHPL-A, ECF, MOD
APPLICANT: Silvija Jakovljevic, Medici Architects, 11661 SE 1st St, Ste 200, Bellevue, WA
98005
PROJECT NAME: 38th Street Short Plat
PROJECT DESCRIPTION: The applicant is requesting Preliminary Short Plat approval, Environmental (SEPA)
Review, and a street Modification for the subdivision of an existing 62,781 square foot project site zoned R-8, into 8 lots
and 2 tracts (shared driveway/alley and native growth protection area). An existing single-family residence is proposed for
removal. The proposed lots would range in size from 5,000 square feet to 6,522 square feet. Access to the proposed lots
would be provided via a shared driveway/alley off of NE 38th Street. Half street improvements, including paving, curb and
gutter, landscaping with street trees, and sidewalk would be provided along the site's Lincoln Ave NE and NE 38th Street
frontages. The site is mapped with erosion hazard areas, landslide hazard areas, sensitive slopes, and protected slopes.
The applicant is proposing to retain 17 of the existing 102 significant trees located on the project site.
PROJECT LOCATION: 700 S 3rd St, Renton, WA 98057
LEAD AGENCY: City of Renton
Environmental Review Committee
Department of Community & Economic Development
The City of Renton Environmental Review Committee has determined that it does not have a probable significant adverse
impact on the environment. An Environmental Impact Statement (EIS) is not required under RCW 43.21C.030(2)(c).
Conditions were imposed as mitigation measures by the Environmental Review Committee under their authority of
Section 4-9-070D Renton Municipal Code. These conditions are necessary to mitigate environmental impacts identified
during the environmental review process. Because other agencies of jurisdiction may be involved, the lead agency will not
act on this proposal for fourteen (14) days.
Appeals of the environmental determination must be filed in writing on or before 5:00 p.m. on July 5, 2019. Appeals
must be filed in writing together with the required fee with: Hearing Examiner, City of Renton, 1055 South Grady Way,
Renton, WA 98057. Appeals to the Examiner are governed by RMC 4-8-110 and more information may be obtained from
the Renton City Clerk’s Office, (425) 430-6510.
PUBLICATION DATE: June 21, 2018
DATE OF DECISION: June 17, 2018
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7C
6/17/2019 | 11:36 AM PDT
6/17/2019 | 2:45 PM PDT
6/17/2019 | 11:25 AM PDT
6/18/2019 | 2:26 PM PDT
DocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Project Location Map
ERC_Report_38th Street Short Plat_FINAL
ENVIRONMENTAL REVIEW COMMITTEE REPORT
ERC Meeting Date: June 17, 2019
Project File Number: PR18-000554
Project Name: 38th Street Short Plat
Land Use File Number: LUA18-000683, SHPL-A, ECF, MOD
Project Manager: Jill Ding, Senior Planner
Owner: Sapphire, LLC, 331 NW 78th St, Seattle, WA 98117
Applicant: Emily Buchwalter, Medici Architects, 11661 SE 1st St, Ste 200, Bellevue, WA
98005
Contact: Silvija Jakovljevic, Medici Architects, 11661 SE 1st St, Ste 200, Bellevue, WA
98005
Project Location: 1825 NE 38th St, Renton, WA 98056
Project Summary: The applicant is requesting Preliminary Short Plat approval, Environmental
(SEPA) Review, and a street Modification for the subdivision of an existing
62,781 square foot project site zoned R-8, into 8 lots and 2 tracts (shared
driveway/alley and native growth protection area). An existing single-family
residence is proposed for removal. The proposed lots would range in size from
5,000 square feet to 6,522 square feet. Access to the proposed lots would be
provided via a shared driveway/alley off of NE 38th Street. Half street
improvements, including paving, curb and gutter, landscaping with street trees,
and sidewalk would be provided along the site's Lincoln Ave NE and NE 38th
Street frontages. The site is mapped with erosion hazard areas, landslide hazard
areas, sensitive slopes, and protected slopes. The applicant is proposing to
retain 17 of the existing 102 significant trees located on the project site.
A Modification to the City's adopted street standards has been requested for the
portion of N 38th Street to the west of the proposed private access driveway.
The applicant is requesting to waive the frontage improvements along the steep
slopes and to limit the frontage improvements to a sidewalk, parking area, and
landscaped courtyard over the proposed stormwater vault.
Exist. Bldg. Area SF: N/A Proposed New Bldg. Area (footprint):
Proposed New Bldg. Area (gross):
N/A
N/A
Site Area: 62,781 sq. ft. Total Building Area GSF: N/A
STAFF
RECOMMENDATION:
Staff Recommends that the Environmental Review Committee issue a
Determination of Non-Significance- Mitigated (DNS-M).
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
City of Renton Department of Community & Economic Development
38th Street Short Plat
Staff Report to the Environmental Review Committee
LUA18-000683, SHPL-A, ECF, MOD
Report of June 17, 2019 Page 2 of 3
ERC_Report_38th Street Short Plat_FINAL
ENVIRONMENTAL REVIEW
In compliance with RCW 43.21C.240, the following environmental (SEPA) review addresses only those project
impacts that are not adequately addressed under existing development standards and environmental regulations.
A. Environmental Threshold Recommendation
Based on analysis of probable impacts from the proposal, staff recommends that the Responsible Officials:
Issue a DNS-M with a 14-day Appeal Period.
B. Mitigation Measures
1. Project construction shall comply with the recommendations outlined in the Geotechnical
Engineering Report, prepared by ZipperGeo, dated October 12, 2018.
2. A 25-foot buffer and additional 15-foot building setback shall be required from the top edge of the
protected slope area.
C. Exhibits
Exhibit 1: Environmental Review Committee (ERC) Report
Exhibit 2: Colored Site Plan
Exhibit 3: Colored Landscape Plan
Exhibit 4: Preliminary Short Plat Map
Exhibit 5: Geotechnical Engineering Report, prepared by ZipperGeo, and dated October 12, 2018
Exhibit 6: Advisory Notes
D. Environmental Impacts
The Proposal was circulated and reviewed by various City Departments and Divisions to determine whether the
applicant has adequately identified and addressed environmental impacts anticipated to occur in conjunction
with the proposed development. Staff reviewers have identified that the proposal is likely to have the following
probable impacts:
1. Earth
Impacts: The project site is mapped with erosion hazard areas, landslide hazard areas, sensitive slopes,
and protected slopes. The applicant submitted a Geotechnical Engineering Report (Exhibit 5), prepared
by ZipperGeo, and dated October 12, 2018. According to the submitted report, the topography of the
site slopes moderately down to the west to the top of a protected slope. The total vertical relief of the
property occurs between the southeast and northwest property boundaries and is about 58 feet.
Vegetation on the site generally consists of deciduous and coniferous trees and brush with areas of
ornamental landscaping. Published maps indicate that the project site is underlain by Vashon Till, which
is a non-sorted mixture of clay, silt, sand, pebbles, cobbles, and boulders in variable amounts.
Subsurface conditions were evaluated through the completion of 2 test borings (B-1 and B-2) on the
project site. Boring B-1 was conducted on the southeastern portion of the project site and boring B-2
was conducted on the southwestern portion of the project site. Both borings were advanced to a depth
of about 41.5 feet below grade. Surficial soils conditions observed in the borings generally consisted of
about 6 to 8 inches of forest duff and topsoil. Below the forest duff and topsoil, soil conditions observed
in borings generally consisted of about 7 to 10 feet of loose to medium dense sand and silt. Below the
loose to medium dense sand and silt, soil conditions observed in the borings generally consisted of
medium dense to very dense sand and very stiff to hard silt to the completion depths of about 41.5 feet
below existing site grade. The medium dense to very dense sand and very stiff to hard silts observed in
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
City of Renton Department of Community & Economic Development
38th Street Short Plat
Staff Report to the Environmental Review Committee
LUA18-000683, SHPL-A, ECF, MOD
Report of June 17, 2019 Page 3 of 3
ERC_Report_38th Street Short Plat_FINAL
the borings is interpreted to be glacial till. Perched groundwater was encountered at a depth of about
15 feet in both borings.
The submitted geotechnical report recommends a 25-foot buffer with an additional 15-foot building
setback from the edge of the protected slope area. In addition, it is recommended that earthwork
activities be conducted during the drier summer months (May 1-September 30). The report also includes
recommendations for site preparation, structural fill materials and preparation, underground utilities,
temporary and permanent slopes, residential building foundations, permanent foundation retaining
walls, site retaining walls, rockeries, MSE and gravity block walls, stormwater infiltration feasibility,
stormwater detention vault, on-grade concrete slabs, and permanent drainage. Staff recommends, as
SEPA mitigation that the above mitigation recommended in the submitted Geotechnical Engineering
Report (Exhibit 5) be required during project construction.
Mitigation Measures:
1. Project construction shall comply with the recommendations outlined in the Geotechnical
Engineering Report, prepared by ZipperGeo, dated October 12, 2018.
2. A 25-foot buffer and additional 15-foot building setback shall be required from the top edge of the
protected slope area.
Nexus: SEPA Environmental Regulations, Critical Areas Regulations – RMC 4-3-050
E. Comments of Reviewing Departments
The proposal has been circulated to City Department and Division Reviewers. Where applicable, their comments
have been incorporated into the text of this report and/or “Advisory Notes to Applicant.”
Copies of all Review Comments are contained in the Official File and may be attached to this report.
The Environmental Determination decision will become final if the decision is not appealed within the 14-day
appeal period (RCW 43.21.C.075(3); WAC 197-11-680).
Environmental Determination Appeal Process: Appeals of the environmental determination must be filed in
writing together with the required fee to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA
98057, on or before 5:00 p.m. on July 5, 2019. RMC 4-8-110 governs appeals to the Hearing Examiner and additional
information regarding the appeal process may be obtained from the City Clerk’s Office, Renton City Hall – 7th Floor,
(425) 430-6510.
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
CITY OF RENTON
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT
STAFF REPORT TO THE ENVIRONMENTAL REVIEW COMMITTEE
EXHIBITS
Project Name:
38th Street Short Plat
Land Use File Number:
LUA18-000683, SHPL-A, ECF, MOD
Date of Meeting
June 17, 2019
Staff Contact
Jill Ding
Senior Planner
Project Contact/Applicant
Silvija Jakovljevic
Medici Architects
11661 SE 1st St, Ste 200,
Bellevue, WA 98005
Project Location
1825 NE 38th St, Renton, WA
98056
The following exhibits are included with the ERC Report:
Exhibit 1: Environmental Review Committee (ERC) Report
Exhibit 2: Colored Site Plan
Exhibit 3: Colored Landscape Plan
Exhibit 4: Preliminary Short Plat Map
Exhibit 5: Geotechnical Engineering Report, prepared by ZipperGeo, and dated October 12, 2018
Exhibit 6: Advisory Notes
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
TREE #1216
LOD 7'-0"
TREE #936
LOD 11'-0"TREE #935
LOD 9'-0"
TREE #934
LOD 6'-0"
TREE #933
LOD 9'-0"
TREE #932
LOD 9'-0"
TREE #929
LOD 7'-0"
TREE #1036
LOD 6'-0"
TREE #1037
LOD 6'-0"
TREE #1038
LOD 6'-0"
TREE #1039
LOD 6'-0"
TREE #1040
LOD 15'-0"
TREE #1077
LOD 11'-0"
TREE #1068
LOD 6'-0"
TREE #1073
LOD 6'-0"
TREE #1058
LOD 8'-0"
TREE #1053
LOD 11'-0"
TREE #1052
LOD 6'-0"
TREE #997
LOD 13'-0"
TREE #1004
LOD 6'-0"13'-812"TREES #1080-1093TREE #1110
LOD 13'-0"
TREE #1066
NON-VAIBLE
TREE #1099
NON-VAIBLE
TREE #1069
TREE #1100
TREE #1101
26'-0"
45
6
WALKWAY
FG 176'LINCOLN AVE NE5' SIDEWALK8' PLANTER STRIP15 FEET
BUILDING
SETBACK
25 FEET
BUFFER
SHARED DRIVEWAY N-SNE 38TH STREET
DEAD END STREET
5' SIDEWALK
CRITICAL
AREA
890 SF 8' LANDSCAPE STRIP
IN TRACT20'-0"8' PLANTER
170'
FG154'
FG 176'
FG 180'
FG 170'
FG 172'FG 184'
FG 188'
MAIN
FFE 163'
176'
FG
154'
FG 153'
FG
146'FG
146'
FG
152'
FG 146'
FG
164'
FG 164'PLANTERFG 158'FG
164'
FG 170'
FG
166'
FG 170'
FG 166'FG 167' FG154'
FG 160'
SHARED DRIVEWAY E-W PLANTERFG 156'FG 185'FG 162.5
4' GRAVITY
WALL
15 FEET
BUILDING
SETBACK
62'-6"62'-5"15'-0"FRONTYARD15'-0"
FRONT
YARD5'-0"SIDE15'-0"
FRONT
YARD
24'-0"
R2
5
'
-
0
"15'-0"FRONTYARD20'-0"FRONTYARD20'-0"FRONTYARD5'-0"SIDEYARD20'-0"REARYARD20'-0"
REAR
YARD
15'-0"
FRONT
YARD
20'-0"
REAR
YARD
5'-0"
SIDE
YARD
5'-0"SIDEYARD18'-0"REARYARD10%reduction13'-5"
FRONT
YARD
10%
reduction 15'-0"
FRONT
YARD30'-0"20'-0"REPAVEMENT60'-0" ROWR25'-0"5'-0"SIDE20'-0"REARYARD5'-0"
SIDE
5'-0"
SIDE
5'-0"
SIDE
5'-0"
SIDE
5'-0"
SIDE
5'-0"
SIDE
R
2
5
'
-
0
"
R25'-0"R25'-0"62'-1012"R25'-0"
R
2
5
'
-
0
"8'-0"STEPSEXISITING EDGE OF
PAVEMENT
FG 150'
FG 160'
FG 168'
FG 152'
FG 146.5'FG 143'FG 152.5'
FG 149'
80'-0"
67'-6"58'-0"61'-8"80'-11"80'-0"69'-5"66'-0"93'-3"82'-9"1
MAIN ENTRY
FFE 167.5'
GARAGE
FFE 153.0'5'-0"SIDE2
MAIN ENTRY
FFE 176.5'
GARAGE
FFE 162.0'
3
MAIN ENTRY
FFE 185.5'
GARAGE
FFE 171.0'5'-0"SIDE25'-0"
BUFFER
15'-0"
BUILDING
SETBACK
26'-3"
22'-9"
26'-3"
FG 168'6'-0"FG 165'FG 161'
FG 160'FG 154'
FG 158'
FG156'
FG 176'
182'
FG 158'
+ 4'-0" TOW
BOW EL A
T
R
O
W
FG
160'
FG 152'
FG
160' 176' 184' 186' 190' 180'
11%
9%
11%FG 143'FG 143'FG 144'FG 148'TREE #1039
LOD 6'-0"
TREE #1040
LOD 15'-0"
TREE #936
LOD 11'-0"
TREE #932
LOD 9'-0"
TREE #1216
LOD 7'-0"
TREE #1053
LOD 11'-0"
TREE #935
LOD 9'-0"
TREE #934
LOD 6'-0"
TREE #1036
LOD 6'-0"
TREE #933
LOD 9'-0"
TREE #929
LOD 7'-0"
TREE #1004
LOD 6'-0"
TREE #997
LOD 13'-0"13'-812"TREE #1037
LOD 6'-0"
TREE #1038
LOD 6'-0"
TREES #1080-1093
TREE #1066
NON-VAIBLE
TREE #1110
LOD 13'-0"TREE #1077
LOD 11'-0"
TREE #1069
TREE #1100
TREE #1068
LOD 6'-0"
TREE #1073
LOD 6'-0"
TREE #1058
LOD 8'-0"
TREE #1101
TREE #1052
LOD 6'-0"
TREE #1099
NON-VAIBLE
MAIN
FFE 156'MAIN
FFE 152'
8 7
MAIN/GARAGE
FFE 152'MAIN/GARAGE
FFE 149'STEPSSTEPSPORCH
PORCHPORCH
PORCH PORCH
PORCHPORCHPORCHSTEPSSTEPSTOW EL. A
T
R
O
W
E
L
.
TOW EL. A
T
R
O
W
E
L
.
TOW EL. A
T
R
O
W
E
L
.
TREES
#1011-1013
LOD 6'-0"
8' LANDSCAPE STRIP
IN TRACT
TREES
TO REMAIN, TYP
LLA AREA 2 - 80 SF
EXISITING EDGE OF
PAVEMENT
2 FEET ROW
DEDICATION 415 SF
'
GARAGE
FFE 152.5'
GARAGE
FFE 145.5'
GARAGE
FFE 141.5'
5' SIDEWALK
GRASS CRETE
MAINTENENCE RD
9'x20' VISITOR PS
9'x20' VISITOR PSVAULT
PER CIVIL PLANS
WOOD FENCE
RETAINING WALL
6' MAX HEIGHT, TYP
SITE PLAN
A0.0
PARCEL LOCATION
VICINITY MAP
NTS
EB
ST, SJ
PROJECT No.:
DATE:
Drawn By:
Owner Approval:
Checked By:
JOB ADDRESS:
PROJECT / CLIENT:
REVISIONS:DATE:
This drawing is the exclusive property of Medici
Architects, and can be reproduced only with the
permission of the Architect. Variations and
modifications to work shown on this drawing
shall not be carried out without written permission
from the Architect.
PLOT SCALE: 1:1
DRAWING NAME:
PHASE:
REGISTRATION:
1.
2.
3.
4.
5.
SITE PLANNING
2018 004
05-06-19
APPROVED FOR CONSTRUCTION:
INTAKE:DATE:
38TH STREET SHORT PLAT
1825 NE 38TH STREET
RENTON, WA PIN# 334570-0220
KP DEVELOPMENT GROUP
338 NW 77TH STREET
SEATTLE, WA 98117PROJECT INFORMATION
DESCRIPTION: DEMOLISH EXISTING SFR, PURSUE
SHORT PLAT TO ACHIEVE EIGHT (8) LOTS
ADDRESS: 1825 NE 38TH STREET, RENTON 98056
PARCEL # 334570-0220
LOT SIZE: 62,781 SF/ ACRES: 1.44
ZONE: R - 8
MIN. LOT SIZE 5,000 SF
MIN. LOT WIDTH: 50'/60'
MIN. LOT DEPTH: 80'
MAX. DENSITY: 8 DU/ac
SETBACK:
FRONT - 20' (15')
SIDE - 5' MIN
REAR - 20'
BUILDING COVERAGE 50%
IMPERVIOUS SURFACE AREA 65%
MAX NUMBER OF STORIES: 2
MAX WALL PLATE HEIGHT: 24'
SITE PLAN
SCALE 1" = 20'-0"
N
LOT SIZE
LOT SIZE PER SURVEY 62,788 SF
LLA AREAS TO SUBTRACT 2,367 SF
ROW DEDICATIONS 1,350 SF
GROSS AREA OF PROPERTY 59,071 SF
LOT 1 - CORRNER LOT 5,000 SF
LOT 2 5,005 SF
LOT 3 5,000 SF
LOT 4 - CORRNER LOT 5,000 SF
LOT 5 5,027 SF
LOT 6 - CORRNER LOT 6,153 SF
LOT 7 5,089 SF
LOT 8 6,522 SF
PROJECT TEAM:
OWNER:
KP DEVELOPMENT GROUP
CAMERON DAMSKOV
331 NW 78TH STREET
SEATTLE, WA
E: cameron@damskovconstruction.com
ARCHITECT:
MEDICI ARCHITECTS
EMILY BUCHWALTER, AIA
11661 SE 1ST ST., SUITE 200
BELLEVUE, WA 98005
P: 425-453-9298
F: 425-452-8448
E: emily@mediciarchitects.com
1825 NE 38TH STREET, RENTON
CIVIL ENGINEER:
PREFERRED ENGINEERING, LLC
STEVE LEE, PE
11627 SE 58TH STREET
BELLEVUE, WA 98006
P: 206-501-5708
E: steve@pellc.org
GEOTECHNICAL ENGINEER:
ZIPPER GEO, INC
ROBERT A.ROSS, PE
19019 36TH AVENUE WEST, SUITE E
LYNWOOD, WA 98036
P: 425-582-9928
E: rross@zippergeo.com
LANDSCAPE:
JGM LANDSCAPE ARCHITECTS
CRAIG LEWIS
12610 NE 104TH ST.
KIRKLAND WA 98033
P: 425-454-5723
E: jgm@jgm-inc.com
SURVEYOR:
EASTSIDE CONSULTANTS, INC
ROBERT BOGDON
1320 NW MALL ST., SUITE B
ISSAQUAH, WA 98027
P: 425-392-5351
E: RBogdon@eastsideconsultants.com
ARBORIST:
AMERICAN FOREST MANAGEMENT
MICHAEL TOMCO
11415 NE 128TH ST., SUITE 110
KIRKLAND, WA 98034
P: 425-820-3420
E: Michael.Tomco@AFMforest.com
PARCEL LOCATION
QT SEC MAP
NTS
N
N
LINCOLN AVE NE 38TH
QUIRED STN
EXHIBIT 2
RECEIVED
05/06/2019 jding
PLANNING DIVISION
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
TREE #1216LOD 7'-0"TREE #936LOD 11'-0"TREE #935LOD 9'-0"TREE #934LOD 6'-0"TREE #933LOD 9'-0"TREE #932LOD 9'-0"TREE #929LOD 7'-0"TREE #1036LOD 6'-0"TREE #1037LOD 6'-0"TREE #1038LOD 6'-0"TREE #1039LOD 6'-0"TREE #1040LOD 15'-0"TREE #1077LOD 11'-0"TREE #1068LOD 6'-0"TREE #1073LOD 6'-0"TREE #1058LOD 8'-0"TREE #1053LOD 11'-0"TREE #1052LOD 6'-0"TREE #997LOD 13'-0"TREE #1004LOD 6'-0"13'-812"TREES #1080-1093TREE #1110LOD 13'-0"TREE #1066NON-VAIBLETREE #1099NON-VAIBLETREE #1069TREE #1100TREE #1101LINCOLN AVE NE
5' SIDEWALK
8' PLANTER STRIP 15 FEETBUILDINGSETBACK25 FEETBUFFERVAULT PER CIVIL PLANSSHARED DRIVEWAY N-S NE 38TH STREETDEAD END STREET5' SIDEWALKCRITICALAREA890 SF8' LANDSCAPE STRIPIN TRACT8' PLANTER170' FG154'180'PLANTER
FG 158'
FG
165'FG 170'FG
166'EG186'18'-0"EG139'FG 144'SHARED DRIVEWAY E-WPLANTER
FG 160'
PLANTER
FG 156'4' GRAVITYWALL15 FEETBUILDINGSETBACKR25'-0"R25'
-0
"
20'-0"
REAR
YARD
R25'-0"R25'
-0
"R2
5
'
-
0
"R25'
-0
"R25'-0"LLA AREA 1 - 2,285 SFLLA AREA 2 - 80 SFEXISITING EDGE OFPAVEMENT2 FEET ROWDEDICATION 415 SFEXISITING EDGE OFPAVEMENTFG 150'FG 160'FG 168'FG 152.5'PLANT SCHEDULE:TREE REPLACEMENT TOTALS:ABCDEFEEEECEEFFFFFBBBBAAAAACCCCCCDDDDDDDACAACCATREE #936LOD 11'-0"GARAGEFFE162'MAIN FLOORFFE 174'MAIN FLOORFFE 164'ENTRYPORCHFFE 167.5'DAYLIGHTBASEMENTFFE 173.5'ENTRYPORCHFFE 185.5'WALKWAYWALKWAYWALKWAYFG 178'5' SIDEWALK
8' PLANTER STRIP DAYLIGHTBASEMENTFFE 164.5'5' SIDEWALK8' PLANTER FG154'FG 177'FG 180'FG 170'FG 182'FG 172'FG 184'FG 188'180'ENTRYPORCHFFE 176.5'FG 164'FG 164'GARAGEFFE152'GARAGEFFE171'MAIN FLOORFFE 183'FG
164'FG 170'FG 176'FG
166'EG 189.5'FG 170'FG 166'FG 167' FG154'FG 160'FG 166'FG 160'FG 185'MAIN FLOORFFE 152'ENTRYPORCHFFE 151.5'GARAGEFFE 154.5'GARAGEFFE 141.5'MAIN FLOORFFE 152'PATIOFG 148.5'STEPS
STEPSFG 150'GARAGEFFE 152'FG 161'5' SIDEWALKMAIN FLOORFFE 149'ENTRY PORCHFFE 160.5'MAIN FLOORFFE 155.5'FG 145.5'FG 139'MAIN FLOORFFE 165'FG 160'FG 165' FG154'158'FG154'FG 153'FG146'FG146'FG152'FG 146'ENTRYPORCHFFE 144.5'STEPSGARAGEFFE 146'ENTRYPORCHFFE 147.5'FG 145'FG 143'FG 145.5'GARAGEFFE 149'FG 144'FG 143'FG 144'FG 148'FG 144'FG 144'FG 143'FG 144'FG 151'LANDSCAPE AREAFG 162.5PATIOFG 155.0PATIOFG 150PATIOFG 151.5'4' GRAVITY WALLTREES#1011-1013LOD 6'-0"DEDCBDDCSTEPS
STEPS
STEPS
PLANTING PLANL1.0SCALE 1" = 20'-0"NINCORPORATED P.S.12610 NE 104TH ST.KIRKLAND WA 98033SITE PLANNINGPARKS ANDURBAN DESIGNRECREATION PLANNINGLANDSCAPE ARCHITECTUREE-: jgm@jgm-inc.comFX: 425.822.3525 PH: 425.454.5723 JGM1825 N.E. 38TH ST.RENTON, WALINCOLN AVE NW NE 38TH STNEXHIBIT 3RECEIVED05/06/2019 jdingPLANNING DIVISIONDocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
EXHIBIT 4
RECEIVED
11/19/2018 jding
PLANNING DIVISION
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
GEOTECHNICAL ENGINEERING REPORT
Proposed 38th Street Short Plat
1825 NE 38th Street
Renton, Washington
Project No. 2002.01
October 12, 2018
Prepared for:
KP Development
Prepared by:
Entire Document
Available in
Laserfiche
Submittals Folder
EXHIBIT 5
RECEIVED
11/19/2018 jding
PLANNING DIVISION
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 2 LUA18-000683
ADVISORY NOTES TO APPLICANT
The following notes are supplemental information provided in conjunction with the administrative land use
action. Because these notes are provided as information only, they are not subject to the appeal process for
the land use action.
Planning:
(Contact: Jill Ding, 425-430-6598, jding@rentonwa.gov)
1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless
otherwise approved by the Development Services Division.
2. Commercial, multi-family, new single family and other nonresidential construction activities shall be
restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through
Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight
o’clock (8:00) p.m. No work shall be permitted on Sundays.
3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an
appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where
no further construction work will occur within ninety (90) days. Alternative measures such as mulch,
sodding, or plastic covering as specified in the current King County Surface Water Management Design
Manual as adopted by the City of Renton may be proposed between the dates of November 1st and
March 31st of each year. The Development Services Division’s approval of this work is required prior to
final inspection and approval of the permit.
4. A National Permit Discharge Elimination System (NPDES) permit is required when more than one acre is
being cleared.
5. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or
fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the
area defined by the drip line of any tree to be retained.
6. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around
the drip lines of all retained trees, or along the perimeter of a stand of retained trees. Placards shall be
placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on
each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups
of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the
applicant shall provide supervision whenever equipment or trucks are moving near trees.
7. This permit is shall comply with the Bald and Golden Eagle Protection Act. The permitted is responsible
for adhering to the U.S. Fish and Wildlife Service National Bald Eagle Management Guidelines (2007) and
/or your U.S. Fish and Wildlife Service permit.
Development Engineering:
(Contact: Jonathan Chavez, 425-430-7288, jchavez@rentonwa.gov)
1. See Attached Development Engineering Memo dated June 6, 2019.
Fire Authority:
(Contact: Corey Thomas, 425-430-7024, cthomas@rentonwa.gov)
1. The fire impact fees are currently applicable at the rate of $829.77 per single family unit. This fee is
paid at building permit issuance. Credit will be granted for the existing home that is planned to be
removed.
EXHIBIT 6
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
ADVISORY NOTES TO APPLICANT
Page 2 of 2 LUA**-000***
2. The fire flow requirement for a single family home is 1,000 gpm minimum for dwellings up to 3,600
square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum
of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet
of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. The existing fire
hydrants are not within 300 feet of all of the proposed new lots. A minimum of one new hydrant will
be required.
3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved,
with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to
support a 30-ton vehicle with 75-psi point loading. Access is required within 150-feet of all points on
all the buildings. Dead end streets that exceed 150-feet in length require an approved hammerhead
type turnaround. Maximum roadway grade allowed is 15 percent.
Technical Services:
(Contact: Amanda Askren, 425-430-7369, aaskren@rentonwa.gov)
1. No comments at this time.
Community Services:
(Contact: Leslie Betlach, 425-430-6619, lbetlach@rentonwa.gov)
1. Parks Impact fee applies.
Police:
(Contact: Cyndie Parks, 425-430-7521, cparks@rentonwa.gov)
1. No comments at this time.
Building:
(Contact: Craig Burnell, 425-430-7290, cburnell@rentonwa.gov)
1. No comments at this time.
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
DEPARTMENT OF COMMUNITY
& ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:June 6, 2019
TO:Jill Ding, Senior Planner
FROM:Jonathan Chavez, Civil Engineer III
SUBJECT:LUA-Application Comments for 38th Street Short Plat
LUA18-000683
I have reviewed the Land Use Application submittal for the 38th Street Short Plat at 1825 NE 38th
Street (KC Parcel ID: 3345700220). The applicant is proposing to subdivide the existing lot into 8
lots for single family homes. The existing home is proposed to be removed.
EXISTING CONDITIONS
The Site is approximately 1.46 acres in size and is trapezoidal in shape. The existing site is
developed with an existing single family residence and a large amount of trees located
throughout the parcel.
Water Water service is provided by the City of Renton. The site is in the Kennydale water
service area in the 320’ hydraulic pressure zone. The approximate static water pressure
is 71 psi at an elevation of 155’. Static water pressure varies based on topography.
There is an existing 12” water main east of the site in Lincoln Avenue NE that can
provide 2,500 gallons per minute (gpm). Reference COR Project File WTR2700400 in
COR Maps for record drawings.
Sewer Sewer service is provided by the City of Renton. There is an existing 8” sewer east of the
site along the western frontage of Lincoln Avenue NE that flows from south to north.
Reference COR Project File WTR2703908 and WWP2702843 in COR Maps for record
drawings.
Storm The site contains an existing single family home surrounded by wooded area. There is no
mapped on-site conveyance system. The current site topography appears to drain the
runoff from the site to the northwest. The site and offsite areas to the northwest
contain moderate and high landslide hazards, high erosion hazard areas, and regulated
slopes up to a 90% grade. There is a 12” public storm drain east of the site along the
eastern frontage of Lincoln Avenue NE that flows from south to north. There is also an
existing stormwater conveyance swale north of the site in NE 38th Street that flows from
east to west.
Streets The proposed development fronts Lincoln Ave NE along the east property line. Lincoln
Ave NE is classified as a Residential Access street. Existing right-of-way (ROW) width is
approximately 60 feet. The proposed development fronts NE 38th Street along the north
property line. NE 38th Street is classified as a Residential Access street. Existing right-of-
way (ROW) width is approximately 60 feet.
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
38th Street Short Plat – LUA18-000683
Page 2 of 7
June 6, 2019
CODE REQUIREMENTS
WATER
1. A minimum of 8” diameter water main extension will be required in NE 38th Street and
all private alleys in the development. The new 8” water mains should connect to the
existing 12” water main in Lincoln Avenue NE. The new water main(s) shall extend to the
southern boundary of the proposed subdivision.
a. A 15-foot utility easement will be required for the new water main(s), hydrants
and water meters within the property.
2. Below is a summary of the existing fire hydrants in the vicinity of the site. Installation of
additional fire hydrants and/or modification of existing fire hydrants may be required by
the Renton Regional Fire Authority (RRFA) to meet development standards.
a. At the northwest corner of the intersection of Lincoln Avenue NE and NE 38th
Street (HYD-NE-01075).
b. Along the western frontage of Lincoln Avenue NE approximately 110’ south of
the site.
3. The new lots shall be served by a new 1” water service with a 3/4" or 1” water meter. A
1” meter is required if the new home contains a fire sprinkler system. The sizing of the
meter(s) shall be in accordance with the most recent edition of the Uniform Plumbing
Code.
4. A backflow prevention assembly shall be installed on private property behind the
domestic water meter. A double check valve assembly (DCVA) is required for water
meters for residential water use. DCVA’s that are 2-inches or smaller shall be installed in
a meter box.
5. A pressure reducing valve is required downstream of the meter if the water pressure
exceeds 80 psi.
6. If irrigation is proposed for the common areas, a landscape irrigation meter and double
check valve assembly is required (DCVA).
7. Civil Construction plans for the water main improvements will be required and must be
prepared by a professional engineer registered in the State of Washington. Please refer
to City of Renton General Design and Construction Standards for Water Main Extensions
as shown in Appendix J of the City’s 2012 Water System Plan. Adequate horizontal and
vertical separations between the new water main and other utilities (storm sewer pipes
and vaults, sanitary sewer, power, gas, electrical) shall be provided for the operation
and maintenance of the water main. Retaining walls, rockeries or similar structures
cannot be installed over the water main unless the water main is installed inside a steel
casing.
8. The development is subject to applicable water system development charges (SDC’s)
and meter installation fees based on the number and size of the meters for domestic
uses and for fire sprinkler use. The development is also subject to fees for water
connections, cut and caps, and purity tests. Current fees can be found on the City’s
website. Current fees will be charged at the time of construction permit issuance.
a. The SDC fee for water is based on the size of the new domestic water to serve the
project. The current water fee for a single 1-inch meter is $4,050.00 per meter.
b. The SDC fee for fire service is based on the size of the fire service line to serve the
project.
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
38th Street Short Plat – LUA18-000683
Page 3 of 7
June 6, 2019
c. Water service installation charges for each proposed domestic water service is
applicable. Water Service installation for a 1-inch water service line is $2,875.00*
per service line.
d. Drop-in meter fee is $460.00* per meter for a 1-inch meter. This is payable at
issuance of the building.
e. Final determination of applicable fees will be made after the water meter size has
been determined. SDC fees are assessed and payable at construction permit
issuance.
SEWER
1. The existing on-site septic system serving the existing home shall be decommissioned in
accordance with King County Department of Health and City of Renton standards.
2. New 6” side sewers with a minimum slope of 2% connecting to the existing sewer main
in Lincoln Avenue NE will be required for all lots fronting Lincoln Avenue NE and lots
where a gravity connection is possible. Private utility easements will be needed for any
side sewer that passes through an adjacent lot prior to connecting to the existing sewer
main.
3. For lots where a gravity connection to the existing sewer main in Lincoln Avenue NE is
not possible, individual grinder pumps and force mains will be required for each lot. The
private force main should connect to a 6” sewer stub that is a minimum of 2% in slope.
Private utility easements will be needed for any force main or gravity side sewer that
passes through an adjacent lot prior to connecting to the existing sewer main.
4. The development is subject to a wastewater system development charge (SDC) fee. SDC
fee for sewer is based on the size of the new domestic water to serve the project. The
current sewer fee for a 1-inch meter install is $3,100.00 per meter. Each lot shall have a
separate meter.
SURFACE WATER
1. Drainage plans and a drainage report complying with the adopted 2017 Renton Surface
Water Design Manual (RSWDM) will be required. Refer to Figure 1.1.2.A – Flow Chart in
the 2017 RSWDM to determine what type of drainage review is required for this site.
The site falls within the City’s Flow Control Duration Standard (Forested Conditions).
The site falls within the May Creek drainage basin.
2.There are regulated slope, erosion hazard, and landslide areas found along the western
side of the property. Due to the steep slopes downstream of the project, the project
must comply with the Flood Problem Flow Control standard. Therefore, if stormwater
will be discharged to the steep slope area then the project must match the Flow
Duration of pre-developed rates for Forested Conditions from 50% of the 2-year up to
the full 50-year flow, match Forested Site Conditions for the 2- and 10-Year Peaks, and
match Existing Site Conditions for the 100-Year Peaks.
3. On-site BMPs satisfying Core Requirement #9 will be required for the site and each
individual lots to the extent feasible. On-site BMPs shall be evaluated in order of
preference by feasibility as described in Section C.1.3 of the 2017 RSWDM. Final review
and approval of the lot BMPs will be evaluated during the review of the Building Permit
Application.
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
38th Street Short Plat – LUA18-000683
Page 4 of 7
June 6, 2019
4. Any new storm conveyance installed on or off-site shall be designed and sized in
accordance with standards found in Chapter 4 of the 2017 RSWDM. New storm drains
shall be designed to account for the total upstream tributary area, assuming developed
conditions for onsite tributary areas and existing conditions for any offsite tributary
areas. Lot owners shall have full, equal, and undivided private ownership and
maintenance responsibility of any stormwater network constructed on-site outside of
the public ROW. Capture of storm drainage along both site frontages will be required.
a.Each lot must have a direct connection to the storm system.
5. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the
applicant will be required to provide basic water quality treatment. All proposed
stormwater facilities shall be designed in accordance with the current RSWDM at the time
of civil construction permit application. Separate structural plans will be required to be
submitted for review and approval under a separate building permit for all proposed
detention and/or water quality vaults.
a.Install additional anaerobic grate for ease of maintenance.
6. The flow control or water quality stormwater facilities may be constructed in the public
ROW and shall be privately maintained by lot owners. The lot owners shall have full,
equal and undivided private ownership and maintenance responsibility of the
stormwater facilities. Maintenance access shall be provided to the inlet, outlet, and any
control or emergency overflow storm structures of the stormwater facility. Per Core
Requirement #1 of the 2017 RSWDM, all stormwater runoff must be discharged at the
natural location and comply with discharge requirements 1, 2, and 3 of Section 1.2.1.
a.Provide capacity calculations for existing ditch. The discharge point must
designed to eliminate any erosion potential downstream.
b. Applicant must apply for an easement with the City to be able to construct and
maintain private facilities in public right-of-way.
7. A geotechnical soils report for the site is required per the 2017 Renton Surface Water
Design Manual Section C.1.3. Information on the water table and soil permeability
(measured infiltration rates), with recommendations of appropriate on-site BMPs per
Core Requirement #9 and Appendix C shall be included in the report. The report should
also include information concerning the soils, geology, drainage patterns and vegetation
present shall be presented in order to evaluate the drainage, erosion control and slope
stability for site development of the proposed plat. The applicant must demonstrate the
development will not result in soil erosion and sedimentation, landslide, slippage, or
excess surface water runoff.
8. A Construction Stormwater General Permit from the Washington Department of Ecology
will be required if site clearing equals one acre or more.
9. As of September 28, 2018, the City of Renton has developed a new set of Surface Water
Standard Plans to replace the existing set. These new Surface Water Standard Plans shall
be used in all future drainage plan submittals.
10. The development is subject to stormwater system development charges (SDCs) for the
new lots. The 2019 Surface water system development fee is $1,800.00 for each new
lot. The SDC that is current is due at the time of construction permit issuance.
TRANSPORTATION
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
38th Street Short Plat – LUA18-000683
Page 5 of 7
June 6, 2019
1. Lincoln Avenue NE is classified as a residential access street. Per RMC 4-6-060, the
minimum right of way width for a residential access street is 53’. The minimum paved
roadway width is 26’ consisting of 2 – 10’ travel lanes and 1 – 6’ bike lane. A 0.5’ curb,
8’ planter strip, and 5’ sidewalk are required along both sides of the pavement.
Per the King County Assessor’s Map, the existing right of way width for Lincoln Avenue
NE adjacent to the site is approximately 60’. The existing Lincoln Avenue NE paved
roadway width adjacent to the site is approximately 24’ to 32’. There is no curb and
gutter, planter strip, or sidewalk along the project frontage. The majority of the existing
roadway lies in the western half of the right of way.
Installation of a 0.5’ curb, 8’ planter strip, and 5’ sidewalk will be required along the
frontage. The new curb adjacent to the project site shall be set 18.4’ west of the right of
way centerline. The 8’ planter and 5’ sidewalk should be installed directly behind the
curb. A right of way dedication of approximately 2’ will be required along the project
frontage to accommodate the frontage improvements.
The offset of the frontage improvements and right of way dedication is required to
straighten out the roadway. The required roadway section for Lincoln Avenue NE is
consistent with the required roadway section for Carpenter Short Plat (LUA14-001200)
located to the south of this site.
2. NE 38th Street is classified as a residential access street. The existing right of way for NE
38th Street is only partially improved along the project frontage. The existing roadway
width is approximately 24’ near the intersection with Lincoln Avenue NE. The road
curves within the right of way and serves as an access to the driveways of 1820 and
1825 NE 38th Street. Per the King County Assessor’s Map, the existing right off way
width for NE 38th Street adjacent to the site is approximately 60’.
A half residential access street will be required along the project’s NE 38th Street
frontage. Per RMC 4-6-060, the minimum right of way width for a half residential access
street is 35’. The minimum paved roadway width 20’ consisting of 2 – 10’ travel lanes. A
0.5’ curb, 8’ planter strip, and 5’ sidewalk are required along the project frontage.
a.Show shoulder treatment, retaining wall, and guard rails in profile views.
Guardrails shall be per WSDOT standard specifications. Retaining walls within
public right of way shall be designed per AASHTO standards.
3. A curb return radius of 25’ is required at the intersection of NE 38th Street and Lincoln
Avenue NE.
a.Curb ramps must meet ADA requirements to the maximum extent feasible.
4. If a shared driveway is proposed as part of this development it shall meet the design
standards found in RMC 4-6-060. Shared driveways may be allowed for access to four
(4) or fewer residential lots. Shared driveways shall be wholly in a tract. Shared
driveways shall not be more than 200’ in length. The paved surface shall be a minimum
of 16’ but may be up to 20’ to meet Renton Regional Fire Authority standards. The
maximum grade of the shared driveway shall not exceed 15%. Drainage improvements
per City standards are required along the shared driveway. An access easement shall
cover the entirety of the tract.
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
38th Street Short Plat – LUA18-000683
Page 6 of 7
June 6, 2019
5. Street lighting per City standards is required along the project’s Lincoln Avenue NE and
NE 38th Street frontages as the proposed development is larger than 4 residential units.
A street lighting plan and photometric analysis should be submitted at the time of
construction permit submittal.
6. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay
Requirements.
7. The transportation impact fee is based on the type of land use. For a single family
dwelling, the 2019 transportation impact fee is $7,820.42. Transportation impact fees
are subject to change based on the calendar year the building permit is issued.
GENERAL COMMENTS
1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along
property frontage or within the site must be underground. The construction of these
franchise utilities must be inspected and approved by a City of Renton inspector.
2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft
from the right-of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls.
a.Show all retaining walls on profile view. No walls shall be greater than 6’.
3. Retaining walls that are 4’ or taller from bottom of footing and stormwater detention
vaults will require a separate building permit. Structural calculations and plans prepared
by a licensed engineer will be required as part of the building permit review.
a.There are retaining walls above 4 feet and a stormwater detention vault in your
project design.
b.Retaining walls within public right of way shall be designed in accordance with
AASHTO standards. The structural design of these retaining walls shall be
reviewed as part of the Civil Construction Plan Review by a third party reviewer
to be paid for by the applicant as specified by the City of Renton Fee Schedule.
4. Adequate separation between utilities as well as other features shall be provided in
accordance with code requirements:
a.Provide rim and invert elevations on all drainage and sewer structures.
b. 7-ft minimum horizontal and 1-ft vertical separation between storm and other
utilities is required with the exception of water lines which require 10-ft
horizontal and 1.5-ft vertical.
i.Revise utility plan to show minimum horizontal distance of 10 feet
between storm and water mains.
ii.Revise utility plan to show minimum horizontal distance of 7 feet
between storm and sewer mains.
c. The stormwater line should be minimum 5 feet away from any other structure or
wall or building.
i.Revise utility plan to show minimum horizontal distance of 5 feet
between storm pipe and retaining walls, structures, etc.
d. Trench of any utility should not be in the zone of influence of the retaining wall
or of the building.
5. All civil construction permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil
Engineer shall prepare the civil plans. Please visit the Development Engineering Forms
page for the most up-to-date plan submittal requirements:
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED
38th Street Short Plat – LUA18-000683
Page 7 of 7
June 6, 2019
http://rentonwa.gov/business/default.aspx?id=42473
6. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on
separate sheets.
7. A demo permit is required for the demolition of the existing building. The demo permit
shall be acquired through the building department.
8. Fees quoted in this document reflect the fees applicable in the year 2019 only and will be
assessed based on the fee that is current at the time of the permit application or issuance,
as applicable to the permit type. Please visit www.rentonwa.gov for the current
development fee schedule.
DocuSign Envelope ID: 0DD0488B-0612-4AC1-AD49-04E0C47D2B7CDocuSign Envelope ID: 523E0867-EA95-4EA9-9874-25B5926265ED