Loading...
HomeMy WebLinkAboutR-411005LEGEND O T T I 0 1 0 W I- rr Lu z W U z Z) G 45 0 U cn LL_ J 75 H o, I 0 00 0 un r� 0 00 0 N N LLi z Li.l _J LL— I I ASPHALT SURFACE BOL O BOLLARD �x55b�5bbb�S BUILDING CENTERLINE ROW CO CLEANOUT CULVERT PIPE 77 CONCRETE SURFACE DITCH (FLOWLINE) --X X FENCE LINE (CHAIN LINK) FENCE LINE (WOOD) FIRE HYDRANT >- GUY ANCHOR CATCH BASIN (TYPE 1) LUM LUMINAIRE MAILBOX (RESIDENTIAL) ►�� MONUMENT IN CASE (FOUND) PST ❑ POST PH ❑ POWER HAND HOLE P ❑ POWER METER P POWER (OVERHEAD) PP O POWER POLE 0----0 POWER POLE W/ LIGHT O REBAR AS NOTED (FOUND) REBAR & CAP (SET) ROCKERY SS ^� SEWER LINE SEWER MANHOLE 4 j SIGN (AS NOTED) STORM MANHOLE SD STORM DRAIN LINE TS HHE:J TRAFFIC SIGNAL HAND HOLE SIZE TYPE(D TREE (AS NOTED) WM ❑ WATER METER WV m WATER VALVE W WATER LINE G GAS LINE PP #3169663 ONpuses T 535 81. P P IP Ce7 UUUtsLL SUL 170.42' CALC'D � (170.4. 170.4W SSy� SSMH 3FW SO� ( MRI=468.42' UNABLE TO OPE- STRUCTURE FOUND REBAR/CAP LS #10356 0.06'W OF PROP COR 'R1 S9 =RS, cP NOTE: CONTOURS SOUTH OF PROPERTY LINE ARE APPROXIMATE BASED ON LIMITED DATA AND DO NOT REFLECT STRUCTURES OR OTHER FEATURES SOUTH OF LINE. 8" CP IE=465.75 12" CMP IE=464.95'�? Xx6 \ N0. 1 FIELD CHECKS N0. 2 TITLE REPORT N0. 3 ADD GAS LINE N0. 4 ADD TOPO ENTRANCE N0. 5 TITLE BLOCK UPDATE NO. I REVISION TGC 05/14/18 TGC 06/08/ 18 TGC 02/05/20 J P H 03/20/20 J P H 04/20/20 !Bkvm��� SURVEYED: DESIGNED: DRAWN: CHECKED: AP P R I APPROVED: SSP✓ RIM=465.80' CENTER OF 8" CONC CHANNEL(N,S&W)=458.18' 12" CPP IE=464.57--, TGC EJG/JGM SCALE: 1 " 20' ONE INCH AT FULL SCALE U I VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 SDMH RIM=465.53' IE(N) 12"CONC=462.73' IE(E) 12"CONC=462.43' IE(W) 12"CONC=463.23' IE(S) 12"CONC=463.13' CB (TYPE 1) RIM=457.57' IE(N) 4"PVC=454.52' IE(NE) 4"PVC=454.57' IE(W'LY) 8"CPEP=454.32 EL=459.7' ROOF EL=482.1'* -41zoi2e�l • 0TY OF *AR vftli7 RENTON Planning/Building/Public Works Dept. ITEM NO. 7 — ELECTRIC TRANSMISSION LINES EASEMENT, REC. NO. 9406092430 Z�'7M ITEM NO. 9 — WATER EASEMENT AGREEMENT REC. NO. 9508031611 l.6 � I Tr-L I f RIM=464.88' IE(E) 12"CPEP=456.58' P P F G G *46'57" F" 7aa Or,' CB (TYPE CB (TYPE 1) RIM= 01' RIM=457.59' I 12"CPEP=454.06' IE(N) 12"CPEP=454.44' IE(SE) 12"CPEP=453.91' IE(S) 12"CPEP=454.39' IE(W) 12"CPEP=454.16' IE(NW) 12"CPEP=454.84' dSD = 's s SID SID SID SD 10 ROOF EL=482.1'* CB (TYPE 1) _RIM=458.97' IE(N) 12"CONC=453.87 IE(S) 12"CONC=454.27' SD CB (TYPE 1) RIM=458.36' IE(E) 8"CPEP=455.26' IE(W) 8"CPEP=455.46' GG G C \I W W —— W — SSMH RIM-466.66' CENTER OF 8" CONC CH AN N EL(S&N W)= 459.76 T n rr W 9 SID z W U I R-411005 IN COMPLIANCE WITH CITY OF RENTON STANDARDS z LIVI EVELOPMENT ENGINEERING Sippo 07/08/2020 O U I F— C� DATE: FAMILY —FIRST —COMMUNITY —CENTER 4/22/2020 CIVIL_ CONSTRUCTION —PERMIT FIELDBOOK: I PAGE: NW 1 /4 OF NW 1 /4 SEC 28, TWP. 23N., RGE 05E., W.M. DRAWING NO: 16022116TH AVE SE, RENTON, WA 98058 180345 PARCEL NO.2823059034 SHEET: 5 OF: 40 H L.L.