Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Ex02_Tier 1 TUP Decision with Exhibits LUA20-0000164
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT PLANNING DIVISION TIER 1 TEMPORARY USE PERMIT PROJECT NUMBER: LUA20-000164, TP PROJECT NAME: Seattle Seahawks Covid Testing Site PROJECT MANAGER: Clark H. Close, Senior Planner APPLICANT: Stephanie Budz, BioReference 481 Edward H. Ross Drive Elmwood Park, NJ 07407 OWNER: Port Quendall Company d/b/a Seattle Seahawks 12 Seahawks Way Renton, WA 98056 LOCATION: 12 Seahawks Way, Renton WA 98056 DATE OF DECISION: July 14, 2020 DATE OF EXPIRATION: July 14, 2021 DESCRIPTION: The applicant is requesting approval of a Tier 1 Temporary Use Permit for a Covid-19 testing site located at 12 Seahawks Way (APN 2924059015; Exhibit 2). The site is currently occupied by the existing Virginia Mason Athletic Center- Seahawks Headquarters (Seahawks Training Facility). The temporary healthcare structure is a mobile office trailer (Exhibit 3) that would be located approximately 412 feet from Seahawks Way and 165 feet from Lake Washington near the northwest corner of the exiting building. The area is currently used for vehicle parking. The proposed mobile trailer is 64 feet long (including the hitch), 12 feet wide, and has a ceiling height of eight (8) feet. The trailer would be supported by a fresh water tank, grey water tank, mobile generator, and a fuel tank to provide for the generator (Exhibits 4-6). The supporting equipment would be placed on the sides of the trailer. The trailer includes stairs and an ADA ramp and would be used by players, coaches and employees. No ground disturbances or other site work is proposed with the temporary use. The Temporary Use Permit is hereby Approved with Conditions* and subject to the following conditions: *CONDITIONS OF APPROVAL: The site occupied by the temporary use shall be left free of debris, litter, or other evidence of the temporary use upon completion of removal of the use, or when the operation of the use ceases to exist. DocuSign Envelope ID: 06FE2F84-78BD-4662-B28E-BF8B77218346 City of Renton Department of Community & Economic Development Administrative Temporary Use Permit LUA20-000164, TP Seattle Seahawks Covid Testing Site Temporary Use Permit Page 2 of 2 DECISION DATE: 07/14/2020 SIGNATURE: Date For Jennifer Henning, Planning Director RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened by the approval body. The approval body may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he finds there was misrepresentation or fact. After review of the Reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the 14-day appeal time frame. APPEALS: Due to Governor Jay Inslee’s Proclamation 20-25 (“Stay Home, Stay Healthy”), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. If the situation changes such that the City Clerk’s Office is open when you file your appeal, you have the option of filing the appeal in person. EXPIRATION: A Temporary Use Permit is valid for up to one year from the effective date of the permit, unless the Community & Economic Development Administrator or designee establishes a shorter time frame or an applicant can request that a permit be valid beyond the one year expiration, for up to five years at the time of application or prior to permit expiration. EXTENSIONS: Extension requests do not require additional fees and shall be requested in writing prior to permit expiration to the Department of Community & Economic Development Administrator. DocuSign Envelope ID: 06FE2F84-78BD-4662-B28E-BF8B77218346 7/14/2020 | 2:56 PM PDT RECEIVEDClark Close 07/13/2020PLANNING DIVISIONEXHIBIT 2 RECEIVED Clark Close 07/13/2020 PLANNING DIVISION EXHIBIT 3 wackerneuson.com – compiled on 03.07.2020 Page 1 Heavy-duty mobile generators for reliable power The G70 is a prime powered generator designed to withstand the rigors of repeated transport and continuous loads. The compact, sound-attenuated model provides single and three-phase power for construction, commercial, industrial and special event applications where quiet power is needed. With the DOC/SCR and Tier 4 Final Kohler engine, the need to replace the costly DPF is eliminated, lowering the total cost of ownership. Tier 4 Final Kohler engines provide industry leading 4-year, 4,000 hour warranty. Maintenance-free, filter-free, and regeneration-free aftertreatment eliminates the need for costly DPF filters. Ideally suited for applications such as lighting, cranes, concrete mixers, and conveyor belts where a continuous power supply is crucial. Optional features such as 600V, Level Load Logic, two-way fuel valve, fuel filter and block heater, as well as camlocks provide the flexibility to perform on any job site. Single side access service point makes daily maintenance quick and simple. Standard variable speed fan provides fuel savings, noise reduction, and maximized performance for hot and cold weather conditions. G70 NEW Mobile Generators RECEIVED Clark Close 07/13/2020 PLANNING DIVISION EXHIBIT 4 wackerneuson.com – compiled on 03.07.2020 Page 2 G70 NEW Technical specifications Dimensions L x W x H Operating (Skid)96.5 x 38.0 x 63.2 in L x W x H Shipping (Skid)100 x 40.5 x 70.2 in L x W x H Shipping (Trailer)160 X x 67.5 x 85 in Weights Weight Dry (Skid)3,750 lb Weight Operating (Skid)4,510 lb Weight Shipping (Skid)3,906 lb Weight Operating (Trailer)5,390 lb Weight Shipping (Trailer)4,630 lb Operating data Trailer coupling Type Pintle Standby output 63 kW Standby output 79 kVA Prime output 58 kW Voltage - AC 3 Phase 240/480 V Current - 3 Phase (Prime)174 / 87 A Current - AC 1 Phase 120 / 240 A Voltage - 3 Phase 208, 220, 240, 416, 440, 480 V Voltage - 1 Phase 120, 127, 139, 240, 254, 277 V Circuit breaker (Main)250 A Frequency 60 Hz Power factor 3 Phase 0.8 cos Φ 3~ Sound level (LwA) at Prime (23 ft / 7 m)68 dB(A) Battery (1000 CCA)12 V Receptacles -20 Amp GFI Duplex 2 Receptacles -50 Amp Twist Lock 3 Receptacles -30 Amp Twist Lock - Engine / Motor Engine / Motor Liquid-Cooled, 4 Cylinders Engine / Motor manufacturer Kohler KDI3404 Emissions Certified Tier 4 Final Displacement 205 in³ Operating performance SAE J1940 ./ J1995 104 hp at rpm 1,800 rpm Coolant Capacity 21.5 US qt Engine oil Capacity 15.8 US qt Fuel type Diesel #1/#2 ULSD Fuel consumption (Prime Load)4.2 US gal/h wackerneuson.com – compiled on 03.07.2020 Page 3 Tank capacity -Fuel 112 US gal Quantity (Battery)1 Generator model Mecc Alte, Brushless w/AVR Voltage control No Load to Full Load +/-1 % Voltage control Steady State +/-0.2 % Generator insulation (class) H Frequency (Generator Speed)60 Hz Runtime at 100% Prime Load 25.2 h Runtime at 75% Prime Load 32 h Runtime at 50% Prime Load 47.1 h Runtime at 25% Prime Load 74.7 h DEF Type AUS 32 DEF Consumption 0.07 US gal/h DEF Tank Capacity 5.1 US gal Please note: that product availability can vary from country to country. It is possible that information / products may not be available in your country. More detailed information on engine power can be found in the operator's manual; the stated power may vary due to specific operating conditions. Subject to alterations and errors excepted. Applicable also to illustrations. Copyright © 2020 Wacker Neuson SE. RESTROOM SYSTEMS Office Trailer Overview Our Office Trailer Restroom System provides the most convenient and comfortable portable restroom option during any season. Office Trailer Restroom Systems provide a fully operational bathroom inside your site trailer without the need for a water or sewer connection. Office Trailer Restroom Systems are perfect for construction projects, business locations and mobile command centers, and come backed by our industry leading 8-Point Service Plan performed by our local service technicians. Contact our experts today for your upcoming project. 1-800-toilets · unitedsiteservices.com * Availability, requirements, options, specifications and amenities vary by region and location and may carry additional charges. Options* Winterization Package High waste alarm Waste Tanks Water Tanks Features Space efficient interior design 55 - 100 gallon non-potable water tanks 110 - 300 gallon waste holding tanks Translucent to monitor water levels On-demand electric water pump Low-flush toilet bowl On-call or scheduled service plans Site Requirements (1) 15amp/120 volt electrical circuit Access through floor of trailer At least 20” clearance under trailer SERVICEyou can trust Gals.Height Width Length Gals.Height Diameter 110 154 300 15” 12” 18” 4’ 4’ 5’ 4’ 5’ 8’ 55 100 54” 60” 30” 23” RECEIVED Clark Close 07/13/2020 PLANNING DIVISION EXHIBIT 5 SPECIFICATION DATA SHEET | MODEL : 20TCG-OS The TransCube 20TCG-OS is a double-walled fuel tank certified tank for Superior Environmental Compliance and Ease-of-Use. It is approved to Highest Standards for Safe Off-Shore use. Approved by ABS to EN12079 for safe off-shore use. Approved as a 31AY package for transporting hazardous goods in packing group II and III . Manhole for internal tank inspection, easy clean out and maintenance. Four-way forklift pockets for easy handling. High quality marine grade paint on exterior of tank. Stackable 3 high full or 5 high empty. Double-walled, UL 142 design for environmental protection. Lockable equipment cabinet to secure all fittings and outlets within lockable secondary containment area. SPECIFICATIONS STANDARD FITTINGS: High accuracy contents gauge, 3”Fill point, 2” Fusible link fill port, 1” Pump feed with flexible dip pipe, strainer & non-return valve, (1) Engine feed and Return port set, Pressure/Vacuum vent, Breather vent, Statutory vent. OPTIONAL FITTINGS: Galvanized exterior, Painted interior (not to aviation fuel spec), Additional feeds and returns, Shackles, Lifting slings, Pumps and accessories. Capacity Litres: 1970 Tare Weight (T): 2292 lbs (1040kg) Capacity Imperial Gallons: 434 Payload (P): 4409 lbs (2000kg) Capacity US Gallons: 520 Gross Weight (R): 6701 lbs (3040kg) Dimension Length (mm/in): 2210 mm/87” Approvals: ABS to EN12079, UL142, ULC S-601-07, Dimension Width (mm/in): 1400 mm/55” SUN IBC Type 31A, UN DOT, NFPA, Transport Canada, Dimension Height (mm/in): 1296 mm/51” Vlarem, Kiwa Design Temperature (ºC): -40ºC RECEIVED Clark Close 07/13/2020 PLANNING DIVISION EXHIBIT 6