HomeMy WebLinkAboutCD-41932
1
ROW
TRACT A
PROJECT
SITE
139TH AVE SEFIELD AVE NENE 9TH ST
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169BASIS OF BEARINGS
LEGAL DESCRIPTION
BENCHMARK
SURVEYOR'S NOTES
HORIZONTAL CONTROL DIAGRAM
UTILITY CONTACTS
TESC SUPERVISOR
CITY OF RENTON, WASHINGTON
SE 1/4 OF THE N/W 1/4, SEC. 10, TWP. 23 N., RGE. 5 E., W.M.HARDY SHORT PLAT
CIVIL CONSTRUCTION PERMIT
VICINITY MAP
DESIGN STANDARDS
SITE INFORMATION
SITE INFORMATION
SITE
SHEET INDEX
PERMIT NUMBER
STORM LEGEND
ROAD LEGEND
WATER LEGEND
SEWER LEGEND
EROSION CONTROL LEGEND
SURFACE LEGEND
R-419301
S-419301
CONDITIONS OF APPROVALWWP-27-4193DEVELOPMENT ENGINEERING
YQI 01/26/2022
REGIONAL FIRE AUTHORITY
cthomas 01/26/2022
APPROVED
SURFACE WATER UTILITY
JFarah 01/26/2022
WASTEWATER UTILITY
JStowell 01/27/2022
JDing 01/27/2022
CURRENT PLANNING
FIELD AVE NENE 9TH
S
T
139TH AVE SE450
460
470
12
3
6
5 4
10
9
7
8
X
X
X
X
X
X
TRACT A
1
2
ROW
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169R-419302
DEVELOPMENT ENGINEERING
YQI 01/26/2022
FIELD AVE NE1
2
ROW
TRACT A
12
3
6
5 4
10
9
7
8
X
X
X
X
X
X
NE 9TH S
T
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169R-419303
DEVELOPMENT ENGINEERING
YQI 01/26/2022
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169TREE PROTECTION FENCING
CONSTRUCTION SEQUENCE
R-419304
TREE PROTECTION MEASURES DURING CONSTRUCTION
DEVELOPMENT ENGINEERING
YQI 01/26/2022
FIELD AVE NEROW
1
2
TRACT A
A
A
B B
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169FIELD AVE NE
SECTION B-B
TRACT A
SECTION A-A
R-419305
DEVELOPMENT ENGINEERING
YQI 01/26/2022
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169R-419306
DEVELOPMENT ENGINEERING
YQI 01/26/2022
1
2
ROW
TRACT A FIELD AVE NEHARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169SEE SHEET C4.21
R-419307S-419302WWP-27-4193DEVELOPMENT ENGINEERING
YQI 01/26/2022
SURFACE WATER UTILITY
JFarah 01/26/2022
WASTEWATER UTILITY
JStowell 01/27/2022
NE 9TH S
T
STORM
440
450
460
470
0+00 0+50 1+00 1+50 2+00 2+50
440
450
460
470
440
450
460
470
3+00 3+50
SEE SHEET C4.01HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169R-419308
S-419303MATCH BELOWMATCH ABOVEDEVELOPMENT ENGINEERING
YQI 01/26/2022
SURFACE WATER UTILITY
JFarah 01/26/2022
TRACT A
450
460
470
480
450
460
470
480
10+00 10+50 11+00 11+50 12+00 12+25
FIELD AVE NE
460
470
480
460
470
480
20+00 20+50 21+00 21+50 22+00 22+25
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169R-419309
DEVELOPMENT ENGINEERING
YQI 01/26/2022
SURFACE WATER UTILITY
JFarah 01/26/2022
1
A A
B
B
VAULT B-B
450
460
470
450
460
470
0+50
VAULT A-A
450
460
470
450
460
470
0+50 1+00
1
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169VAULT - EXTERIOR DETAILVAULT - INTERIOR DETAIL
CONTROL STRUCTURE
R-419310
12" IE 456.59
EL 452.59 DRILL OR MACHINE CUT 7/16" Ø
ORIFICE 454.59 IN WELDED
RESTRICTOR END PLATE
6" ELBOW WITH 5/16"Ø ORIFICE EL 462.05
6" ELBOW WITH 1/4"Ø ORIFICE EL 461.65
6" ELBOW WITH 7/16"Ø ORIFICE EL 460.30
RISER ELEV 463.22
MAX.W.S ELEV 463.22
DEVELOPMENT ENGINEERING
YQI 01/26/2022
SURFACE WATER UTILITY
JFarah 01/26/2022
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169R-419311
DEVELOPMENT ENGINEERING
YQI 01/26/2022
SURFACE WATER UTILITY
JFarah 01/26/2022
WASTEWATER UTILITY
JStowell 01/27/2022
HARDY SHORT PLATIN COMPLIANCE WITH CITY OF RENTON STANDARDS PR21-000178C21-004477DESIGN
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
SURVEYINGTED-40-4193PROJECT NO. 21019 LUA-21-000169R-419312
S-419304WWP-27-4193DEVELOPMENT ENGINEERING
YQI 01/26/2022
WASTEWATER UTILITY
JStowell 01/27/2022
12365410978XXXXXX12ROWTRACT AXTREESQTYBOTANICAL NAMECOMMON NAMESIZESPACING3ACER CIRCINATUMVINE MAPLE2" CAL. MIN.AS SHOWNTREE RETENTION TABLEPER R.M.C. 04.04.130.H.1.A.I.TREE RETENTION CALCULATIONSTREE REMOVAL TO BE SUPERVISEDBY ARBORIST TO INSUREPROTECTION OF LIMITS OFDISTURBANCE FOR TREES TOREMAIN (TYP.)SIGNIFICANT TREE TO REMOVE (TYP.)LEGENDSIGNIFICANT TREE TO BE RETAINEDSIGNIFICANT TREE TO BE REMOVEDTREE PROTECTION FENCING6' HT TREE PROTECTION FENCING (TYP.)SEE NOTATION HEREONTOTAL ONSITE SIGNIFICANT TREES:REQUIRED RETAINED SIGNIFICANT TREES:PROVIDED RETAINED SIGNIFICANT TREES:TOTAL REPLACEMENT TREES REQUIRED:9 SIGNIFICANT TREES3 (30 %) = 9 SIGNIFICANT TREES X .303 SIGNIFICANT TREES0 TREESPER R.M.C. 04.04.130.H.9.B.NOTEPROTECTION FENCING SHALL BE CHAIN LINK TEMPORARY CONSTRUCTION FENCINGAROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDINGTHE TREE EQUAL TO ONE AND ONE-QUARTER FEET (1-1/4') FOR EVERY ONE INCH (1") OFTRUNK CALIPER, WHICHEVER IS GREATER. PLACARDS SHALL BE PLACED ON FENCINGEVERY FIFTY FEET (50') INDICATING THE WORDS, “NO TRESPASSING – PROTECTEDTREES,” OR ON EACH SIDE OF THE FENCING. SITE ACCESS TO INDIVIDUALLY PROTECTEDTREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALLBE FENCED ON FOUR (4) SIDES. IN ADDITION, THE APPLICANT SHALL PROVIDESUPERVISION WHENEVER EQUIPMENT OR TRUCKS ARE MOVING NEAR TREES.PER R.M.C. 04.04.130.C.9.DTREE DENSITY CALCULATIONSTREE TO REMAIN (TYP.)LIMITS OF DISTURBANCE (TYP.)OFFSITE TREE (TYP.)ADDITIONAL TREE (TYP.)ADDITIONAL TREE PLANTING SCHEDULELOT NUMBERSQ. FT.TREESREQUIREDTREESREMAINING127,5655,27123TOTAL5033TREESPROVIDED022HARDY SHORT PLAT
IN COMPLIANCE WITH CITY OF RENTON STANDARDSPR21-000178C21-004477DESIGN12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877CIVIL ENGINEERINGLANDSCAPE ARCHITECTUREPLANNINGSURVEYINGTED-40-4193
PROJECT NO. 21019LUA-21-000169BUILDING SETBACK (TYP.)2R-419313JDing 01/27/2022CURRENT PLANNING
12ROWTRACT ATREESQTYBOTANICAL NAMECOMMON NAMESIZESPACING2ACER CIRCINATUMVINE MAPLE2" CAL. MIN.AS SHOWN8MAGNOLIA GRANDIFLORA `LITTLE GEM`DWARF SOUTHERN MAGNOLIA1.5" CAL. MIN.AS SHOWNSTREET TREESQTYBOTANICAL NAMECOMMON NAMESIZESPACING2ACER TRUNCATUMX A. PLATINOIDES 'KEITHSFORM'NORWEGIAN SUNSET MAPLE2" CAL. MIN.30` O.C.SHRUBSQTYBOTANICAL NAMECOMMON NAMESIZESPACING32BERBERIS BUXIFOLIA 'NANA'DWARF BOXLEAF BARBERRY2 GAL.AS SHOWN12CORNUS STOLONIFERA `KELSEYI`KELSEY DOGWOOD2 GAL/18" HT. MIN.AS SHOWN18ERICA CARNEA `VIVELLII`HEATH1 GAL.AS SHOWN6POTENTILLA FRUTICOSA `ABBOTSWOOD`ABBOTSWOOD POTENTILLA2 GAL.AS SHOWN14ROSMARINUS OFFICINALIS 'ARP'ARP ROSEMARY5 GAL./24" HT. MIN.AS SHOWN15SPIRAEA DOUGLASIIWESTERN SPIREA5 GAL./24" HT. MIN.AS SHOWNGROUND COVERSQTYBOTANICAL NAMECOMMON NAMESIZESPACING1,060FESTUCA GLAUCA 'ELIJAH BLUE'ELIJAH BLUE FESCUE4" POT12" O.C.HARDY SHORT PLAT
IN COMPLIANCE WITH CITY OF RENTON STANDARDSPR21-000178C21-004477DESIGN12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877CIVIL ENGINEERINGLANDSCAPE ARCHITECTUREPLANNINGSURVEYINGTED-40-4193
PROJECT NO. 21019LUA-21-000169
HARDY SHORT PLAT
IN COMPLIANCE WITH CITY OF RENTON STANDARDSPR21-000178C21-004477DESIGN12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877CIVIL ENGINEERINGLANDSCAPE ARCHITECTUREPLANNINGSURVEYINGTED-40-4193
PROJECT NO. 21019LUA-21-000169PLANT SCHEDULENOTES:PER R.M.C. 04.04.070.L.1.3.; L.1.4.C.; J.1.ALL SHRUBS MUST BE OF SUFFICIENT SIZE AND NUMBER TO MEET THE REQUIREDSTANDARDS FOR NURSERY PLANT STOCK.2. SHRUBS SHALL BE IN BEDS THAT INCLUDE A LAYER OF MULCH AT LEAST TWO INCHES(2") IN DEPTH.3.TREES SHALL INCLUDE A MULCH RING THAT HAS A DEPTH OF AT LEAST THREE INCHES(3") AND IS AT LEAST THREE FEET (3') IN RADIUS AROUND THE TREE.4.SOIL SHALL BE PREPARED FOR LANDSCAPE INSTALLATION ACCORDING TO INDUSTRYSTANDARDS TO BE CONDUCIVE TO THE HEALTHY GROWTH OF NEW PLANTS. TOPSOILSHALL BE RICH IN ORGANIC MATERIAL OR AMENDED TO BE SO. CLAY SOIL IS NOTACCEPTABLE AND MUST BE REMOVED FROM LANDSCAPE AREAS IF NATURALLYPRESENT ON SITE.5.ALL INSTALLED LANDSCAPING SHALL COMPLY WITH APPLICABLE CITY OF RENTONREQUIREMENTS.6.STREET TREE LOCATIONS ARE APPROXIMATE. ADJUST AS NEEDED DUE TO CONFLICTSWITH UTILITIES AND/0R OTHER OBSTRUCTIONS ENCOUNTERED. ROOT BARRIER TO BEUSED WITHIN ALL PLANTER STRIPS CONTAINING STREET TREES.7.STREET TREES AND PLANTER STRIPS TO BE MAINTAINED BY HOMEOWNERS.8.COMPLIANCE WITH SOIL AMENDMENT BMP PER CITY OF RENTON 2017 SURFACEWATER DESIGN MANUAL IS REQUIRED. SEE SHEET L2.31 FOR BMP DETAIL.SIGNIFICANT TREES TO BE RETAINED (TYP.)STREET TREE (TYP.)TREE (TYP.)10' STREET FRONTAGE LANDSCAPE BUFFER (TYP.)OFFSITE TREE (TYP.)ADDITIONAL TREES (TYP.)GROUND COVER (TYP.)SHRUB (TYP.)PROPERTY LINE (TYP.)BUILDING SETBACK (TYP.)ROOT BARRIER (TYP.);SEE SHEET P7 FOR DETAILR-419314JDing 01/27/2022CURRENT PLANNING
3.011 12 X ROOTBALL DIMENSIONSTAKES SHALL EXTEND A MIN. OF 1' INTOUNDISTURBED SOILDETAIL: PLANTING DECIDUOUS TREE2 x ROOTBALL DIA.RUBBER HOSE AT TREE; HOSE SHALLBE LONG ENOUGH TOACCOMMODATE 1 YEAR'S GROWTHAND BUFFER ALL BRANCHES FROMTHE WIRE3 HARDWOOD STAKES OR OTHERAPPROVED MATERIAL; ALL STAKESTO BE DRIVEN OUTSIDE THEROOTBALL, AT 120° SPACINGGALVANIZED WIRE OR CABLE; TWISTWIRE TO TIGHTEN ONLY ENOUGH TOKEEP FROM SLIPPING (ALLOW FORSOME TRUNK MOVEMENT)STAKING NOTES:PLANT TREE SO THAT THE TRUNKCROWN IS VISIBLE AT THE TOP OF THEROOTBALL; SET TOP OF ROOTBALLFLUSH TO GRADE; DO NOT COVER THETOP OF THE ROOTBALL WITH SOILMIN. 2" MULCH; DO NOT PLACE INCONTACT WITH TRUNK4" HIGH EARTH SAUCER AROUND EDGEOF PLANTING PITFINISH GRADEROUGHEN EDGES OF PITREMOVE ALL TWINE, WIRE ANDBURLAP FROM TOP HALF OFROOTBALL; NONBIODEGRADABLE MATERIALSHALL BE REMOVEDCOMPLETELYTAMP TOPSOIL BACKFILLAROUND ROOTBALL BASEFIRMLY WITH FOOT PRESSURETO AVOID SHIFTING OFROOTBALLPLACE ROOTBALL ONCOMPACTED SOIL PEDESTAL TOPREVENT SETTLINGNOT TO SCALEPLANTSET CROWN OF PLANT ATFINISHED GRADE2" LAYER MULCH;TAPER TO CROWNSAUCER 2" HIGHFINISHED GRADEROOTBALLTOPSOIL BACKFILL &FERTILIZERROUGHEN ALL SURFACESOF PITCUT NEW ROOT MASS TOSTIMULATE NEW ROOT GROWTHUNDISTURBED NATIVE SOIL2 X ROOTBALL DIA.1 12 XROOTBALLDIA.DETAIL: PLANTING SHRUBNOT TO SCALEGROUNDCOVER2" LAYER OF MULCH; TAPER TOCROWNFINISHED GRADEROOTBALLTOPSOIL BACKFILL & FERTILIZERCUT NEW ROOT MASS TOSTIMULATE NEW ROOT GROWTHUNDISTURBED NATIVE SOIL2 X ROOTBALL DIA.1 12 XROOTBALLDIA.EQUALEQUALEQUALPLANTSPACING PERPLANT TYPE;SEE SCHEDULENOTE:TO AVOID LANDSCAPE INTRUSION INTO PATHS,THE FOLLOWING PLANTING SPACING OFF-SETSFROM EDGE OF ALL PATHS, DRIVES, ACCESSROUTES, ETC. SHALL BE MET:GROUND COVER: 18"SMALL SHRUBS (UNDER 3' TALL): 30"MEDIUM SHRUBS (FROM 3' TALL TO 6'): 42"LARGE SHRUBS (OVER 6' TALL): 48"DETAIL: PLANTING GROUNDCOVERNOT TO SCALENOT TO SCALEDETAIL: PLANT SPACING2.0'PLANTER STRIPINSTALL ROOT BARRIER ON ONEOR BOTH SIDES AS NECESSARYDETAIL: ROOT BARRIERNOT TO SCALENOTES:1. INSTALL PRODUCT PER MANUFACTURER'S SPECIFICATIONS.2. INSTALL PRODUCT A MINIMUM OF 3' BEYOND CENTER OF TREE IN EACH DIRECTION PARALLEL TOUTILITY LINE.3. ALL TREES LOCATED WITHIN CLOSE PROXIMITY TO UTILITIES TO RECEIVE ROOT BARRIER.DETAIL: TREE PROTECTION FENCINGCITY OF RENTON6'CRITICAL ROOT ZONEEXISTING TREECONTINUOUS CHAINLINKFENCINGONE SIGN PER 50'(MIN. OF 2 SIGNS)"NO TRESPASSING,PROTECTED TREES"DRIP LINEPOSTS AT 10' O.C. MAXPROTECTION MEASURES DURING CONSTRUCTION:PROTECTION MEASURES IN THIS SUBSECTION SHALL APPLY FOR ALL TREES THAT ARE TO BE RETAINED ON SITE AND OFFSITE.OFFSITE TREES CONTAINING DRIP LINES THAT ENCROACH ONTO THE SITE UNDER CONSTRUCTION SHALL BE CONSIDERED PROTECTEDTREES UNLESS IT IS DETERMINED THE ABUTTING PROPERTY OWNER IS IN COMPLIANCE WITH SUBSECTION C OF THIS SECTION,ALLOWED TREE REMOVAL ACTIVITIES. ALL OF THE FOLLOWING TREE PROTECTION MEASURES SHALL APPLY:A. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, DISPOSE OFANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH IN ANYWAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED.B. FENCED PROTECTION AREA REQUIRED: PRIOR TO DEVELOPMENT ACTIVITIES THE APPLICANT SHALL ERECT AND MAINTAIN SIX-FOOT(6') HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCESURROUNDING THE TREE EQUAL TO ONE AND ONE-QUARTER FEET (1-1/4') FOR EVERY ONE INCH (1") OF TRUNK CALIPER, WHICEVER4IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION TRACT. PLACARDS SHALL BE PLACED ON FENCING EVERY FIFTY FEET(50') INDICATING THE WORDS, "NO TRESPASSING- PROTECTED TREES", OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY FEET(50') . SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREESSHALL BE FENCED ON FOUR (4) SIDES. IN ADDITION, THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT TORTRUCKS ARE MOVING NEAR TREES.C. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE RETAINED IS TO BE RAISED, THEAPPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK WELL AROUND THE TREE. THE DIAMETER OF THIS WALL OR WELL MUSTBE EQUAL TO THE TREE'S DRIP LINE.D. IMPERVIOUS SURFACES PROHIBITED WITHIN THE DRIP LINE: THE APPLICANT MAY NOT INSTALL IMPERVIOUS SURFACE MATERIALWITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED, UNLESS OTHERWISE APPROVED BY THE CITY (ORD.5958, 12-9-2019)E. RESTRICTION ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES: THE GRADE LEVEL AROUND ANY TREE TO BE RETAINEDMAY NOT BE LOWERED WITHIN THE GREATER OF THE FOLLOWING AREAS: (I) THE AREA DEFINED BY THE DRIP LINE OF THE TREE, OR(II) AN AREA AROUND THE TREE EQUAL TO ONE AND ONE-HALF (1-1/2') IN DIAMETER FOR EACH ONE INCH (1") OF TREE CALIPER. ALARGER TREE PROTECTION ZONE BASED ON THE TREE SIZE, SPECIES, SOIL, OR OTHER CONDITIONS MAY BE REQUIRED. (ORD. 5676,12-3-2012)F. MULCH LAYER REQUIRED: ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH AMINIMUM OF THREE INCHES ( 3") OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. EXCEPTIONS MAY BEAPPROVED IF THE MULCH WILL ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS. (ORD. 5676, 12-3-2012)G. MONITORING REQUIRED DURING CONSTRUCTION: THE APPLICANT SHALL RETAIN A CERTIFIED ARBORIST OR LICENSED LANDSCAPEARCHITECT TO ENSURE TREES ARE PROTECTED FROM DEVELOPMENT ACTIVITIES AND/OR TO PRUNE BRANCHES AND ROOTS,FERTILIZER, AND WATER AS APPROPRIATE FOR ANY TREES AND GROUND COVER THAT ARE TO BE RETAINED.H. ALTERNATIVE PROTECTION: ALTERNATIVE SAFECUARDS MAY BE USED IF DETERMINED TO PROVIDE EQUAL OR GREATER TREEPROTECTION. (ORD. 5676, 12-3-2012; ORD. 5841-6-12-2017)NOT TO SCALEDETAIL: SOIL AMENDMENT BMPCITY OF RENTON PUBLIC WORKS DEPT.1/14/2022 9:35 AMJ:\2021\21019\LANDSCAPE\FINAL\SHEETS\21019 L2.31.DWG HARDY SHORT PLAT
IN COMPLIANCE WITH CITY OF RENTON STANDARDSPR21-000178C21-004477DESIGN12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877CIVIL ENGINEERINGLANDSCAPE ARCHITECTUREPLANNINGSURVEYINGTED-40-4193
PROJECT NO. 21019LUA-21-000169R-419315JDing 01/27/2022CURRENT PLANNING