HomeMy WebLinkAboutR-411515Ln
DocuSign Envelope ID: 6EECF5B6-602A4E4A-B436-A317AA638878
PIPE ZONE BEDDING AND
BACKFILL SEE NOTE 4
LL.J FOUNDATION
LEVEL -\
LLJ
O
w
z
z
J
TRENCH WIDTH.JI
SEE NOTE 3 I
r
S'
O.D.
T
1
FOUNDATION MATERIAL,
IF REQUIRED. SEE NOTE 5
TRENCH WIDTH.
SEE NOTE 3
PIPE ZONE BEDDING AND SPAN
BACKFILL. SEE NOTE 4 TT
RISE
FOUNDATION
LEVEL
r FOUNDATION MATERIAL
l IF REQUIRED. SEE NOTE 5
\y PIPE - ARCH
RIGID PIPE NOTES:
I PIPE COMPACTION LIMITS SHOWN ON THIS PLAN ARE FOR PIPE
CONSTRUCTION IN AN EMBANKMENT. FOR PIPE CONSTRUCTION IN
A TRENCH, THE HORIZONTAL LIMITS OF THE PIPE COMPACTION
ZONE SHALL BE THE WALLS OF THE TRENCH.
2. O.O. IS EQUAL TO THE OUTSIDE DIAMETER OF A PIPE OR THE
OUTSIDE SPAN OF PIPE -ARCH,
3 SEE STANDARD WSDOTIAPWA SPECIFICATIONS SECTION 2-09.4 FOR
TRENCH WIDTH
4 PIPE ZONE BEDDING AND RA KFI L MATERIAL LL SHALL BE PLACED
6' LOOSE LAYERS AND COMPACTED TO 95% MAXIMUM DENSITY.
5. EXCAVATE UNSTABLE MATERIAL DOWN i0 FIRM SOIL AND REPLACE
WITH FOUNDATION MATERIAL CLASS A OR B PER STANDARD
W50OVAPWA SPECIFICATIONS SECTION 9-03 17
®GRAVEL BACKFILL FOR PIPE ZONE BEDDING (WSDOT 9-03.12(3))
OR MAINTENANCE ROCK (WSDOT 9-03-914))
MINIMUM
ALLOWED IN ZONE 1
PIPE TYPE
COVER IFTI
PUBLIC7
PRIVATE?
OF THE APA7
CORRUGATED
STEEL PIPE
20
YES
YES
YES
SPIRAL RIB STEEL
20
YES
YES
YES
PIPE
PLAIN CONCRETE
PIPE (PCP)
20
NO
YES
NO
REINFORCED
CONCRETE PIPE
1.0
YES
YES
NO
(RCP)
CORRUGATED OR
SPIRAL RIB
2D
YES
YES
NO
ALUMINUM PIPE
DUCTILE IRON PIPE
1.0
VES
YES
VES
CIRCULAR PIPE
DIAMETER
MINIMUM DISTANCE
BETWEEN BARRELS
12' TO 24"
Ir
30"TOO 96'
DIAMETERl3
1 "T 7
02 80
48'
PIPE -ARCH
SPAN
MINIMUM DISTANCE
BETWEEN BARRELS
18"TO 38'
IT
43• TO 142'
SPAN 13
148' TO 199'
46'
UNLESS OTHER WISE NOTED, DRAWING 15 NOT TO SCALE INTS)
I am STD. PLAN - 220.00
PUBLIC WORKS PIPE ZONE BEDDING AND APPR f0
� DEPARTMENT COMPACTION RIGID PIPE GAZ 9/28/2018 I
DATE
1.5" RADIUS B
(TYP.)
A go
D L
\,---0.3" BORDER (TYP.)
B
A
CEI
SIGN DIMENSIONS
SIGN TYPE
A
B
C
D
E
POST MOUNTED STREET NAME
SIGN (SPEED LIMIT <40MPH)
8"
VARIES
6"
4.5"
3.5"
POST MOUNTED STREET NAME
SIGN (SPEED LIMIT >40MPH)
12"
VARIES
8"
611
5'
GENERAL NOTES:
1. FONT SHALL BE MUTCD D SERIES, UNLESS AN ALTERNATE MUTCD SERIES IS
APPROVED BY THE CITY
2. LETTERS AND NUMERALS SHALL BE CUT FROM 3M ELECTROCUT FILM SERIES 1170
OR APPROVED EQUAL
3. SIGN BLADE SHALL BE FLAT ALUMINUM, TREATED, 0,080 GAUGE
4. SIGN SHEETING SHALL BE 3M HIGH INTENSITY PRISMATIC OR APPROVED EQUAL
5. SIGN MOUNTING HARDWARE SHALL INCLUDE BOLTS, RIVETS SHALL NOT BE ALLOWED
6. FOR SIGN POST DETAILS, SEE CITY OF RENTON STANDARD DETAIL 129, EXCEPT
MOUNTING HEIGHT SHALL BE 9'-0"
COLORS
LEGEND, ARROW HEAD, SEPARATION BAR - WHITE (REFL.)
BACKGROUND - GREEN (REFL.)
POST MOUNTED TD. PLAN- 134
®PUBLIC WORKS STREET NAME SIGNS EROVED:
DEPARTMENT eL 7/30/2018
DATE
:45 AN
Encompass
ENGINEERING & SURVEYING
Western Washington Division
165 NE Juniper Street, Suite 201 R IssaQuah, WA 98027 R Phone: (425) 392-0250
Eastern Washington Division
407 Swiftwater Blvd. IF Cle Elum, WA 98922 IT Phone: (509) 674-7433
DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108
^.� 314' FLAT FACE GOTHIC
D
DObD
5 STORY D q'
DOG❑
8-t10"DIA T I I11
10.1/Y DIA
(2) 318'-16 SS SOCKET HEAD CAP 15' DU
11) OPEN PICKHOLE 1' SCREW (ALLENHEAD) WIVISHRS 5 9"
ON A S" DU BOLT CIRCLE
CAST IRON FRAME AND PAVED AREA (TYP.1
COVER. SEE NOTE 3
72• EXTEND CLEANOUT PO SER
(DIN
IFS --III 2" ABOVE DESIGN PONDING
ELEVATION OR PER PLAN FERNOO GASKETED
QUIK CAP OR SIMILAR
DESIGN PONDING
- _- ELEVATION 4MBED COBBLES
8" CLASS "B- PER ER WSDWSOOT 84)3.1112)
ASPHALT, SEE NOTE 4
1
L 4' COMPACTED SAND OR
GRAVEL BACKFILL FOR DRAINS
PER WSOOT 9-03.12(4) J
CLEANOUT RISER, SEE NOTE 2
CLEANOUT RISER
SOIL TIGHT 45' BEND SEE NOTE 2 ---
WYE
SOIL TIGHT
COUPLER
UNDERDRAIN, FOOTING
DRAIN COLLECTOR, OR
ROOF DRAIN COLLECTOR
PIPE, SEE NOTE 1 � CLEANOUT RISER LOCATED WITHIN
{ + BIORETENTION PONDING AREA
1^/ r I'� IIII�III
TO OVERFLOW S, `}61�T1� 1[l
STRUCTURE OR s1"j`1
STORM MAIN _.
- MECHANICAL PLUG OR
-,1I-INUED CONNECTION
TYPICAL CLEANOUT CONFIGURATION
NOTES:
I DIAMETER TO BE &INCHES MINIMUM PRIVATE &INCHES MINIMUM PUBLIC UNDERDRAIN PIPE PER STD. PLAN 262.10.
2 CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN. FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE
3 FRAME AND COVER SHALL BE EJ PRODUCTS 3675ZIPT AND 3675APT OR APPROVED EQUAL COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MAHKLU'S I UR%C OR
"DRAIN'
4 FOR CLEANDUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF MORETENTION PONDING AREA, POUR 8' THICK, Zx2 SQUARE CONCRETE COLLAR
AROUND FRAME CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,OD0 PSI.
GENERAL NOTES,
1 CLEANOUTS FOR UNDERDRAIN. FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT
EVERY 90 DEGREE OR SECOND 45 DEGREE BEND. AT THE END OF EVERY COLLECTOR PIPE AND AT EACH END OF AN UNDERORAIN PIPE NOT CONNECTED TO AN
OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANC ACCESS TO ALL PIPES.
E
2 ALL FITTINGS SHALL BE SOIL TIGHT.
3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTKIN PONDING WHERE POSSIBLE,
4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
STD. PLAN - 226.00
PUBLIC WORKS
(D
DEPARTMENT STORM SYSTEM CLEANOUT artin Pastucha 8/13/20 C
D DATE
MUTCD SIGN R8-3 (MODIFIES)
NPAT = NO PARKING ANYTIME
*ORIENT NO PARKING SIGN
AT 45 DEGREES FROM STREET
NOTE: NO PARKING SIGN TO BE
BANDED TO STREET LIGHT POLE
(WHERE APPLICABLE) BANDS TO
MATCH STREET LIGHT POLE COLOR,
100' SEPARATION BETWEEN SIGNS
USE DOUBLE ARROW NO PARKING
SIGN AT ALL LOCATION EXCEPT ON
STOP SIGN. USE RIGHT ARROW
ONLY NEAR STOP SIGN.
I
18
DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB34329FFEOC108
'j.`
ADDITIONAL LADDER RUNGS (IN SETS) TO
Z MIN. CLEARANCE TO
y$
\\�\
ALLOW ACCESS TO TANKS OR VAULTS
ANY
PORTION OF FLOW RESTRICTOR
\
WHEN CATCH IS FILLED WITH WATER
TEE INCLUDING ELBOWS
/
\
REMOVABLE WATERTIGHT
COUPLING OR FLANGE
ELBOW RESTRICTOR.
SEE DETAIL AND NOTE 10
ANGLE AS
/
NECESSARY,
/
\
SEE NOTE 7
T MIN.
El MAX
2'MIN.--��
PLATE WELDED TO ELBOW WITH
PLAN VIEW
ORIFICE AS SPECIFIED, SEE NOTE 3
ELBOW RESTRICTOR DETAIL
ELEVATION PER
PLANS
12" MIN. UNDER FRAME 6 SOLID COVER MARKED'DRANI' WITH
PAVEMENT LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50
IBA MA%.
VERTICAL BAR GRATE FOR
SECONDARY INLET
8" MIN. DESIGN WATER
ELBOW RESTRICTOR.RFA'L�
SEE DETAIL AND NOTE10 HANDHOLDS, STEPS, OR LADDER
PIPE SUPPORTS, SEE NOTE 8 r 12' (TYP. )
1.5 . D }i} SEE NOTE B (TYP.)
MIN. Z MIN.
T- I
D
ISOMETRIC i --(-
OUTLET PIPE. SEE i INLET PIPE
NOTES 1 S 5 2'
MIN SHEAR GATE WITH CONTROL ROD FOR
INVERTAND CLEANOUTIDRAIN (ROD BENT AS REQUIRED
ELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH COVER)
12" SECTION OF PIPE ATTACHED BY PER STO. PLAN 237.30
GASKETED BAND TO ALLOW REMOVAL Z
MIN-
12'
WELDED RESTRICTOR PLATE WITH
ORIFICE DU AS SPECIFIED. SEE NOTE 10
NOTES: SECTION A
1 USE A MIMIMUM OF A 54' DIAMETER TYPE 2 CATCH BASIN
Z OUTLET CAPACITY 100-YEAR DEVELOPED PEAK FLOW.
3 METAL PARTS PREFERRED TO BE STAINLESS STEEL. ALUMINIZED STEEL. OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5
4 FRAME AND LADDER OR STEPS OFFSET SO,
A. CLEANOUT GATE IS VISIBLE FROM TOP.
B. CUM&DOWNLESPACE IS CLEAR OF RISER AND CLEANOUT GATE
.
C. FRAME IS GAR OF CURB.
5- IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPEOUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE ID. LESS I
6 PROVIDE AT LEAST ONE 3' X 090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM T-O' VERTICAL SPACING)
7 LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN
B_ LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER,
9. WHEN CONNECTING TO A NEW PIPE. USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL) WHEN CONNECTING
TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE
10 IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REWIRED
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NUS)
STD. PLAN - 237.00
• PUBLIC WORKS FLOW CONTROL STRUCTURE by:
DEPARTMENT RESTRICTOR TEE Martin Pastucha 8/13/20 0
".1{iiiWBB149D. DATE
REVISED PER ASBUILT SURVEY
z 5 REVISIONS PER FIELD CONDITIONS
4 REVISIONS PER FIELD CONDITIONS
38373 REVISIONS PER CITY COMMENTS DATED 6112312021
ISTE ��`" 2 REVISIONS PER CITY COMMENTS DATED 4110712021
`SIGNAL
n� /n'E /one t N0. REVISION
18
DocuSign Envelope ID: 3B1B34D3-7EOA476C-ADB34329FFEOC108
5'.10' GRATE. GRATED ACCESS DOOR, OR LOCKING
18' MAX. FROM CENTER OF
ACCESS PANEL OVER SECOND CELL, FOR VAULTS
FRAME TO STRUCTURE
ACCESS COVER OR DOORS REWIRED.
WHERE SURFACE AREA OF SECOND CELL IS
WALL FOR STEP ACCESS
GREATER THAN 1.250 SQUARE FEET, 4%OF THE
- - - -
TOTAL SURFACE AREA MUST BE GRATED AND A 5'.1 V
REMOVABLE LOCKING PANEL SHALL BE PROVIn FO
OU ET
_
LADDER
WETPOOL
V'SHAPED BOTTOM
-
WIDTH
_ ______
_____________ -_-_
\\
INLET
B" MIN. GRAVITY DRAIN
A
` REMOVABLE BAFFLE OR WALL.
SEE NOTE 2
SEE NOTE 7 (TYP.)
• ��
e-MAX. FROM EDGE OF
OPENING TO STRUCTURE
•
WALL FOR STEP ACCESS
FRAME AND SOLID COVER
WETPOOL LENGTH
IT MIN. VENTILATION PIPES AT
MARKED'DRAIN' WITH
LOCKING BOLTS PER STD-
CORNERS ITYP .I, SEE NOTE 6
PLANS 2D4-40 AND 204.50
4" MIN.
'
PLAN VIEW
6' MAX
'•
'' �' -'�' -' �' �'
SIZE TO CONVEY 100-YEAR
FIRST CELL SIZED FOR
LADDER
DESIGN FLOW WITHOUT
25%T035%OF
SHEAR GATE
OVERTOPPING. B'MIN.
WETPOOL VOLUME
WATER DUALITY (WQJ DESIGN
1Z,MIN
WATER SURFACE IWSb7
INLET .'
12'MIN.
IT
�Y
OUTLET WITH CAPACITY TO
CONVEY 10D-YEAR DESIGN
12'MIN,
WETPDOL
FLOW WITHOUT OVERTOPPING
D
DEPTH
SEE NOTE 71TYP 1 •
MAX��74
3' MIN.
REMBAF4�7T
2' MIN,
i �� VALVE
GRAVITY DRAIN OF GRADE ALLOWS(. PLACE
AS LOW AS GRADE ALLOWS BUT MUST BE 6-
BOTTOM SLOPE 0.5%-2% MIN. ABOVE THE BASE ELEVATION OF VAULT
TOWARD INLET END WALLS OR ABOVE SEDIMENT STORAGE AREA
SECTIONA BOTTOM SLOPE CIS%-2%TOWARD OUTLET
AVERAGE SEDIMENT STORAGE END OF SECOND CELL (RECOMMENDED)
12' MIN. (FIRST CELL) ACCESS DOORS OR REMOVABLE PANEL SEE NOTE 5
WO DESIGN WS 0--\/�\\/�\\
T MIN.
4' MIN.
5y, MIN. (TYP 1
AVERAGE I SEDIMENT ,
STORAGE FIRST CELL)
NOTES: SECTION B
1. THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND
APPLICABLE DESIGN CRITERIA
2 THE VAULT SHALL BE SEPARATED INTO TWO CELLS BY A WALL OR A REMOVABLE BAFFLE. IF A WALL OR NON REMOVABLE BAFFLE IS USED, A 5fD0T . 10FOOT
REMOVABLE MAINTENANCE ACCESS MUST BE PROVIDED FOR BOTH CELLS.
3 FOR VAULTS UNDER ROADWAYS. THE REMOVABLE PANEL MUST BE LOCATED OUTSIDE THE TRAVEL LANES. ALTERNATIVELY, MULTIPLE STANDARD LOCKING
MANHOLE COVERS MAY BE PROVIDED SPACING OF MANHOLE COVERS SHALL BE 12 FEET, MEASURED ON CENTER. TO FACILITATE REMOVAL OF SEDIMENT.
UDDERS AND HAND -HOLDS NEED ONLY BE PROVIDED AT THE OUTLET PIPE AND INLET PIPE.
1. MINIMUM DIAMETER FOR ALL ACCESS OPENINGS, EXCEPT THOSE COVERED BY REMOVABLE PANELS. IS 36INCHES
-
5. REMOVABLE PANEL SMALL BE AT GRAD HAVE STAINLESS STEEL LIFTING EYES AND WEIGH NO MORE THAN 5 TONS PER PANEL
E
8- VAULTS PROVIDING MANHOLE ACCESS AT 12 FOOT SPACING NEED NOT PROVIDE CORNER VENTILATION PIPES. VENTILATION PIPES SHALL BE CAPPED OR
OTHERWISE COVERDESI ED. BUT GNED SO THAT MAINTENANCE PERSONNEL CAN REMOVE FOR VENTILATION.
7. WHEN CONNECTING TO A NEW PIPE. USE A FLEXIBLE CONNECTOR (KOR-WSEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN
CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE.
8 SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE INTS)
STD. PLAN - 249.20
• i PUBLIC WORKS so ib v:
+1� DEPARTMENT WETVAULT Martin Pastucha$/13/202
(iD9iBg49D_. DATE
REQUIRED DIMENSIONS
8' FOR ROCK LINING
12' FOR RIP RAP
TABLE 4.2.2.A.
ter"
PLAN
NTS
PLACE ROCK V ABOVE CROWN
BOTH SIDES OF CHANNEL FOR "A" < 8'
- ONE SIDE OF CHANNEL FOR "A" > 8' -
I-1' MIN.
DISCHARGE PIPE
I i �
FILTER FABRIC
LINER UNDER 1' OR 2'
ROCK ROCK THICKNESS
SEE TABLE 4.4.1.A
PIPE/CULVERT DISCHARGE PROTECTION
CP
04/17/2024
SURVEYED:
SDM
CP
0911512023
DESIGNED:
NEM
CP
09/28/2022
CP
07110112021
DRAWN. TLK
CP
04110812021
CHECKED:
EDM
BY
DATE
APPR
APPROVED:
CJA
NTS
SCALE:
N/A
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATA M
I b:
DocuSign Envelope ID: 6EECF5B6-602AAE4A-B436-A317AA638878
PLANTING BEDSIUNDISTURBED UNDISTURBED TURF(LAWN) AREAS,
VEGETATION, SEE NOTE 1 SEE NOTE 1
UNDISTURBED GRASS: SEED OR SOO
NATIVE VEGETATION 0•
UNDISTURBED NATIVE SOIL UNDISTURBED NATIVE SOIL
OPTION 1 - NO DISTURBANCE
PLANTING BEDS
1'4' ARBORIST WOOD CHIP MULCH.
SEE STD PLAN 262 60
3"OF COMPOST INCORPORATED
INTO 5' OF SITE SOIL (TOTAL
AMENDED DEPTH OF 9.5', FOR A
SETTLED DEPTH OF W)
TURF(LAWN)AREAS
GRASS- SEED OR SOD
1.75' OF COMPOST INCORPORATED INTO
625" OF SITE SOIL (TOTAL AMENDED DEPTH
OF 9.5", FOR A SETTLED DEPTH OF W)
��I�i����i1��:11Zill-
6'
�ISl�llll�lllrllFwl�l I
SUBSOIL SCARIFIED 4• BELOW
SUBSOIL SCARIFIED 4^BELOW
LI- i -'�-
_-('�
COMPOST AMENDED LAYER
COMPOST AMENDED LAYER
- -: _
(12- BELOW SOIL SURFACE)
(12- BELOW SOIL SURFACE)'-
:,
IT
OPTIONS 2, 3, AND 4 - AMEND IN PLACE OR STOCKPILE AND AMEND
PLANTING BEDS TURF ILAWN)AREAS
' 1
3'4"ARBORISt/�
�•.i:
I
f
ICI'
WOOD CHIP
';',ULCH, SEE STD.
/!/
'�
D.�I
GRASS SEED OR SOD
PLAN 262,60
1/
_
I I
NOTES:
AREAS OF NO DISTURBANCE TO BE FENCED
�T1
�1 ICI
AND EXISTING VEGETATION AND SOIL TO BE
PROTECTED FROM CONSTRUCTION IMPACTS.
TIMPORTED
I I I
e^IMPORTED
TOPSOIL MU(
-1-'
-1-
-- -I-
1 I
I
I I
TOPSOIL MIX
GENERAL NOTES:
(COMPACTED
-.
- -I -
�_
- I
I I I
(COMPACTED
DEPTH)
I ,
TT_S�
jl:�
6,
I I I I I
I
DEPTH)
I TO MEASURE SETTLED DEPTH, WATER SOIL
-II,
b
- T I _ 1.1 -
SUFFICIENTLY TO FULLY SATURATE WITHOUT
-rEF
3L'
CAUSING EROSION
..
:. 41
-' ,
SUBSOIL IS
2. COMPOST TO MEET STD. PLAN 262.60.
SUBSOIL IS
T I_
-
= _
. - -
SCARIFIED 6'
BELOW IMPORTED
3. COMPACTION OF TOPSOIL HERE REQUIRED
(VA' 1
SCARIFIED 6'
a ..FLOW IMPORTED
- -
-
_
- -
I _� -
TOPSOIL MIX
TO BE T085%OF STANDARD PROCTOR,
TOPSOILMI%
_
,I
2
-I-.
4. SEE CONSTRUCTION PLANS FOR SPECIFIC
PROJECT REQUIREMENTS
OPTION MPORTED TOPSOIL
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE INTS)
STD. PLAN - 264.00
PUBLIC WORKS
APPR D
SOIL AMENDMENT SECTIONS
C,gIZ 9/28/2018 1
DEPARTMENT
DATE
SEE SLhTMAR GE TABLE
8' MAX
TRENCH SHORING DETAIL
NTS
Know what's below.
Call before you dig.
vRi CITY OF
RENTON
Planning/Building/Public Works Dept.
Erx20' TRENCH SHORING
SHIELD W1 Irk' SCH 8D
PIPE SPREADERS CTYP)
If we go passed 22' depth we will
stack an additional trench box
MIDI DEWATER
J
:45 All
R-41151.3
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SKYHORSE SHORT PLAT
PR 17- 000438
ASBUILT
CONSTRUCTION DETAILS
Q
J
0
Z
L�
C/�
DATE:
0611712024
FIELDBOOK:
PAGE:
O
DRAWING NO:
22587
SHEET: 15 OF: