Loading...
HomeMy WebLinkAboutR-409130— J p. a x \ ----- - \ v 162AID A VE _ — —+ — — — 16+00 15+( 16+53.6 STA. 16+43.03, 5.00' L RIM 513.49 8" 1E OUT 500.00 (S) NE 1/4 SECTION 14., TOWNSHIP 23 N, RANGE 5 E, W. M. SEE SHEET C31 I - p v vd- 0 0 0 N MAPLE HIGHLANDS NOT PART OF PROJECT AREA TAX PARCEL #1457500026 p v t I ' I I 321 -F,lB" PVC ® 1.25% 14+00 11.00` p a KING COUNTY R.O. W. WORK WORK SHOWN IN THIS AREA WITHIN 162ND AVE SE IS IN KING COUNTY RIGHT OF WAY. A PERMIT WILL RE REQUIRED FROM KING COUNTY PRIOR TO THE START OF WORK. RESTORATION WITHIN KING COUNTY RIGHT OF WAY SHALL COMPLY WITH KING COUNTY ROAD STANDARDS. ALL TREES SCHEDULED FOR REMOVAL IN KING COUNTY RIGHT OF WAY WITH AN OUTSIDE DIAMETER OF MORE THAN 4-INCHES SHALL BE MARKED IN THE FIELD AND APPROVED BEFORE REMOVAL. CITY OF KING RENTON R.O. W. COUNTY R. 0. W. —m M M - 13+ 0 ® 114LF8"PVC 06.21% SSMH 12, 48" STA. 13+22.14, 5.00' L---------------- --- --- RIM 511.86 8" 1E IN 496.00 (N) 8" 1E OUT 495.90 (S) M M 12+c O i 211 LF 8" PVC ® 0.50% i 16+53.66 16+40 16+00 15+60 15+20 14+80 14+40 14+00 13+60 13+20 12+80 12+40 SEWER MANHOLE NOTES: I Call 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) �. P I ED/ �O of WASy/ sC tic 53232GIs E NAL 13,21 8 1 D.R. STRONG 2 CONSUL TING ENGINEERS 3 ENGINEERS PLANNERS SURVEYORS 620 - 7Ih AVENUE KIRKLAND, WA 98033 0 425.827.3063 F 425.827.2423 N CITY COMMENTS 11.12.19 INTAKE COMMENTS CITY COMMENTS 07.27.21 REVISION 1. SEWER MANHOLES PER COR STD PLAN 400.1 2. MANHOLE FRAME AND COVER PER COR STD PLAN 401. UTILITY CROSSING NOTE: O UTILITY CROSSING SEE UTILITY CROSSING TABLE ON SHEET C41 FOR MORE DETAILS YLP 02.14.20 YLP SURVEYED: DJC YLP 06.16°21 YLP DESIGNED: YLP YLP 08.13.21 YLP DRAWN: GLB CHECKED: YLP BY DATE APPR APPROVED SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 QATUM C TY OF RENTON U'R vilkw Planning/Building/Public Works Dept. REMOVE EX. CLEANOUT AND REPLACE WITH NEW MH STA. 12+OZ 79, 9. 03' L RIM 504.52 - 8" 1E IN 488.79 (N) 8" 1E OUT 488.69 (S) NORTH GRAPHIC SCALE 0 10 20 40 1 INCH = 20 FT. HORIZONTAL 0 2.5 5 10 1 INCH = 5 FT VERTICAL R-409128 12+00 11+60 S-409103 IN COMPLIANCE WITH CITY OF RENTON STANDARDS C/) 0 WASTEWATER UTILITY ZZ Ann Fowler 09/30/2021 J DEVELOPMENT ENGINEERING 0 njanders 10/01 /2021 = LU DATE: MAPLE HIGHLANDS 09.05.19 162ND AVE SE SEWER PLAN AND PROFILE FIELDBOOK: PAGE: DRAWING 16210 SE 134TH STREET C30 RENTON, WASHINGTON 98059 SHEET OF: 30 41 DRS PROJECT NO. 17020 T C) O m �� H • H 00 T J