Loading...
HomeMy WebLinkAboutMFP22001175.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP22001175 IVR Number: 22001175 Permit Information Permit Name: N.884795 Address/Location:03/09/2022Application Date:0886610010Parcel Number: 780 LOGAN AVE N Permit Type:03/22/2022Issue Date:Franchise Permit Work Class:03/22/2023Expiration Date:Minor Utility Job Number: N.884795Franchise Type:Telephone Description: Lumen to access MHMH1158, MH1157, MH1156, MH1154, and Lumen Ped. Contacts Name Address PhoneTypeBilling Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549ApplicantX Dena Overaa QWEST / Century Link 23315 66th Ave S KENT, WA 98032 B: (206) 345-0173 C: (425) 247-6248 Applicant Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549Contact Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Jesse Patjens Century Link / Lumen Contact Michael Smith Dycom Industries dba North Sky 11818 SE Mill Plain Blvd, SUITE 410 Vancouver, WA 98684 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 7850 S TRAFTON St TACOMA, WA 98409 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Northsky Communications Tawnya Longfellow 22517 88th ave S Kent/WA 98031 Lumen to access MHMH1158, MH1157, MH1156, MH1154, and Lumen Ped. N>884795 780 Logan Ave N 3/31 4/29 MFP22001175 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 3/22/2022 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Austin Sweeney Austin Sweeney 3/9/2022 TRAFFIC CONTROL PLAN JOB # N. 884795. C. 45 PERMIT # N 8TH ST @ PARK AVE N MH-1158 ACCESS RIGHT-LANE CLOSURE Comments: ACCESS MH-1158 LOCATED OFF ROADWAY. RIGHT-LANE CLOSURE WESTBOUND N 8TH ST. ARROW BOARD IS REQUIRED. DRIVEWAYS REMAIN OPEN/ACCESSIBLE. SIDEWALKS REMAIN OPEN/ACCESSIBLE. SPOTTER WILL ASSIST AT WORK AREA. N SPEEDLIMIT 25 N 8TH ST N 8TH ST 1111111111SIDEWALK 11111111PARK AVE NPARK AVE N11 11 11 11 11 11 11 11 11 11 MH-1158 ACCESS SIDEWALK SIDEWALK WORK ZONE 11' X ~400' (TOTAL) LEGEND ARROW BOARD CONES S SPOTTER TRAFFIC LIGHT WORK AREA WORK TRUCK ARROW BOARD MERGING TAPER ~115'W20-1ROADWORKAHEAD100'+-W20-1 ROADWORKAHEAD100'+-W20-1ROADWORKAHEAD100'+- 100'+-100'+-ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2100'+-SPOTTERS SHEET 1 OF 4 Jeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 25 / 30 20' 40' 35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 18035 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 540 1/3 L 50 500 550 600 Designed For: LUMEN Project # N. 884795. C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # 011989 Draw Date: 2/28/2022 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:2/28/2022 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 884795. C. 45 CERT:WA TCS # 011989 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be determined by City of RENTON. UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTERTHIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM:JEFFREY D. HUBBARD, TCS# 011989, JHUBBARD.TCP@GMAIL.COM Comments: SIGN SPACINGMPH "X" 20-25 100' 30 200' 35-40 350' 45+ 500' www.invarion.com MFP22001175 TRAFFIC CONTROL PLAN JOB # N. 884795. C. 45 PERMIT # N 8TH ST @ PARK AVE N MH-1157 ACCESS RIGHT-LANE CLOSURE Comments: ACCESS MH-1157 LOCATED OFF ROADWAY. RIGHT-LANE CLOSURE WESTBOUND N 8TH ST. ARROW BOARD IS REQUIRED. DRIVEWAYS REMAIN OPEN/ACCESSIBLE. SIDEWALKS REMAIN OPEN/ACCESSIBLE. SPOTTER WILL ASSIST AT WORK AREA. N SPEED LIMIT 25 N 8TH ST N 8TH ST 1111111111SIDEWALK11111111PARK AVE NPARK AVE N11 11 11 11 11 11 11 11 11 11 SIDEWALK SIDEWALK LEGEND ARROW BOARD CONES S SPOTTER TRAFFIC LIGHT WORK AREA WORK TRUCK W20-1ROADWORKAHEAD100'+-W20-1 ROADWORKAHEAD100'+-W20-1ROADWORKAHEAD100'+- SHEET 2 OF 4 100'+-100'+-ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2100'+-PLACE IN ADVANCE OF WORK ZONE11DRIVEWAYSPOTTERS WORK ZONE 11' X ~300' TOTAL ARROW BOARD MERGINGTAPER ~115' MH-1157 ACCESS DRIVEWAYJeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 25 / 30 20' 40' 35 / 45 30' 60' ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 18035 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 Designed For: LUMEN Project # N. 884795. C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # 011989 Draw Date: 2/28/2022 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:2/28/2022 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 884795. C. 45 CERT:WA TCS # 011989 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements.2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 36" x 36" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be determined by City of RENTON. UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTERTHIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM:JEFFREY D. HUBBARD, TCS# 011989, JHUBBARD.TCP@GMAIL.COM Comments: SIGN SPACINGMPH "X"20-25 100'30 200' 35-40 350' 45+ 500' www.invarion.com MFP22001175 TRAFFIC CONTROL PLAN JOB # N. 884795. C. 45 PERMIT # N 8TH ST @ PARK AVE N MH-1156 ACCESS RIGHT-LANE CLOSURE Comments: ACCESS MH-1156 LOCATED OFF ROADWAY. RIGHT-LANE CLOSURE WESTBOUND N 8TH ST. ARROW BOARD IS REQUIRED. DRIVEWAYS REMAIN OPEN/ACCESSIBLE. SIDEWALKS REMAIN OPEN/ACCESSIBLE. SPOTTER WILL ASSIST AT WORK AREA. N SPEED LIMIT 25 N 8TH ST MH-1156 ACCESS LEGEND ARROW BOARD CONES S SPOTTER WORK AREA WORK TRUCKW20-1ROADWORKAHEADSPOTTERS SHEET 3 OF 4 WORK ZONE 11' X ~300' TOTAL ARROWBOARD MERGING TAPER ~115' 200'+-200'+-ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2200'+-1111111111111111DRIVEWAYDRIVEWAYN 8TH ST200'+- SIDEWALK SIDEWALK SIDEWALK SIDEWALK PARK AVE N ~300' Jeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTH TAPER ("L") LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 5401/3 L 50 500 550 600 Designed For: LUMEN Project # N. 884795. C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # 011989 Draw Date: 2/28/2022 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:2/28/2022 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 884795. C. 45CERT:WA TCS # 011989 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 36" x 36" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City of RENTON. UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTER THIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM: JEFFREY D. HUBBARD, TCS# 011989, JHUBBARD.TCP@GMAIL.COM Comments: SIGN SPACING MPH "X"20-25 100'30 200'35-40 350'45+ 500' www.invarion.com MFP22001175 TRAFFIC CONTROL PLAN JOB # N. 884795. C. 45 PERMIT # Comments: ACCESS MH-1154 & 4" UG FIBER PLACEMENT. LANE-SHIFT NORTHBOUND LOGAN AVE N. LEFT-LANE CLOSURE SOUTHBOUND. POLICE OFFICER CONTROLS INTERSECTION. FLAGGERS ASSIST UPO AT INTERSECTION. DRIVEWAYS REMAIN OPEN/ACCESSIBLE. SIDEWALKS REMAIN OPEN/ACCESSIBLE. SPOTTERS WILL ASSIST AT WORK AREAS.NSPEED LIMIT 25 LEGEND ARROW BOARD CONES FLAGGER POLICE OFFICER SPOTTERS SPOTTER WORK AREA WORK TRUCK SHEET 4 OF 4 Jeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT25 / 30 20' 40'35 / 45 30' 60'ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTH TAPER ("L") LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320 TAPER 45 450 495 5401/3 L 50 500 550 600 Designed For: LUMEN Project # N. 884795. C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # 011989 Draw Date: 2/28/2022 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:2/28/2022 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:N. 884795. C. 45CERT:WA TCS # 011989 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 36" x 36" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City of RENTON. UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTER THIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM: JEFFREY D. HUBBARD, TCS# 011989, JHUBBARD.TCP@GMAIL.COM Comments: SIGN SPACING MPH "X"20-25 100'30 200'35-40 350'45+ 500' UPO PLACE IN ADVANCE OF WORK ZONE350' +-350' +-350' +-ROADWORKAHEADW20-1PLACE IN ADVANCE OF WORK ZONE350' +-350' +-350' +-ROADWORKAHEAD W20-1 W20-7W4-2ONLYONLY W1-411111111 11 11 11 11111111TRAFFIC FLOW TRAFFIC FLOW TRAFFIC FLOW LANESHIFTAHEAD W5-5 BIKESMERGE WITHTRAFFICW4-1B100' +-100' +-100' +-W20-7 ROADWORKAHEAD W20-1 BEPREPAREDTO STOP W3-4 SPOTTERSSPOTTERS WORK AREA FOR 4" UG FIBER PLACEMENT MH-1154 ACCESS LOGAN AVE N @ N 8TH ST MH-1154 ACCESS & UG FIBER PLACEMENT LANE-SHIFT & TURN-LANE CLOSURE WITH UPO & FLAGGERS PLACE IN ADVANCE OF WORK ZONE 100' +-100' +-100' +-W20-7ROADWORKAHEADW20-1LOGAN AVE N LOGAN AVE N N 8TH STSIDEWALK SIDEWALK SIDEWALKSIDEWALK SIDEWALK ARROWBOARD S I D E W A L K S I D E W A L K 111111111111 SPEEDLIMIT 25 SPEEDLIMIT 35 SPEEDLIMIT 35 SOUTHBOUND WORK ZONE11' X ~400'NORTHBOUNDWORK ZONE 11' X ~450' (TOTAL) A C C E S S R DBEPREPAREDTO STOPW3-4LEFT LANECLOSEDAHEADW20-5W20-7W1-4 TRAFFIC FLOW TRAFFIC FLOW TRAFFIC FLOW TRAFFIC FLOW www.invarion.com MFP22001175 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.12500000000”NVICINITY MAPCUSTOMER NAME: TOPGOLF INTERNATIONAL, INCLCON: MARK GALINDOPHONE NO: 469-834-4279EMAIL:  mgalindo@arcomurray.comPROJECT ID:  A.2905321ARMOR OR DSR #: 0128-2213313 - N26076981REVISION # SHEET # REASON FOR REVISION REVISED BY DATEREVISION 1 1, 3 & 5 UPDATE COUNT TO INCLUDE - LRE30, 39-40 IN SOW & NOTE ALSO NEW 90°CURVE SL 02/10/22SCOPE OF WORK:POF: @ MANHOLE 1158, SPLICE COUNT WITH LRE30, 31-32 & LRE30, 39-40 FROM [TXD7] ONTO [A3KGE] FALLING TO MANHOLE 1157. @ MANHOLE1157, SPLICE COUNT FROM [A3KGE] ONTO [A3JSJ] FALLING TO MANHOLE 1156. @ MANHOLE 1156, PLACE 480' OF NEW 24 COUNT FIBER INEXISTING CONDUIT TO MANHOLE 1154. @ MANHOLE 1154, PLACE 220' OF NEW 24 COUNT FIBER IN EXISTING CONDUIT TO NEW CBO MEET POINT.@ NEW CBO MEET POINT, NEW 90° CURVE FROM 4" CONDUIT TO JOIN CBO CONDUIT THEN PLACE 150' OF NEW 24 COUNT FIBER THRU CONDUITTO NEW CUSTOMER'S HANDHOLE 1, HANDHOLE 2 TO DEMARC. @ CUSTOMER'S MPOP, TERMINATE LRE30, 31-32 & LRE30, 39-40 IN FDP.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 02/09/2223N4E24N.884795W26226RNTNWA01780 LOGAN AVE N.RENTON, WA 9805715RFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comMFP22001175 TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONHT-CL-YRPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 02/09/2223N4E24N.884795W26226RNTNWA01780 LOGAN AVE N.RENTON, WA 9805725FIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comMFP22001175 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSTOWN:GEO CODE:WC CLLI:NOTE:FOR UNDERGROUND ACTIVITY: TEST ANDVENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY, PLACE WARNING DEVICES AND WORKAREA PROTECTION AS REQUIRED, AND USEEYE AND HEAD SAFETY PROTECTION PERFEDERAL, STATE, AND LOCAL REGULATIONS.RNGE:SECT: EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W EOP EOP EOP R/W R/W R/W PARK AVE N. 6' SIDEWALK 6' SIDEWALKN. 8th STREET6' SIDEWALK6' SIDEWALK805 811 825 909 91541'12'38'55'12'12'13'12'12'49'T115'12'T24'11' EOP EOP 5' PLANTERLMN MH 1157 POF LMN MH 1158NOTE:@ MANHOLE 1157, SPLICE COUNTFROM [A3KGE] ONTO [A3JSJ]FALLING TO MANHOLE 1156.NOTE:POF: @ MANHOLE 1158, SPLICE COUNTWITH LRE30, 31-32 & LRE30, 39-40 FROM[TXD7] ONTO [A3KGE] FALLING TOMANHOLE 1157.RMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 02/09/2223N4E24N.884795W26226RNTNWA01780 LOGAN AVE N.RENTON, WA 9805735FIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.com30SPEEDLIMIT12'11'12'12'5' PLANTER35'45'MFP22001175 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSTOWN:GEO CODE:WC CLLI:NOTE:FOR UNDERGROUND ACTIVITY: TEST ANDVENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY, PLACE WARNING DEVICES AND WORKAREA PROTECTION AS REQUIRED, AND USEEYE AND HEAD SAFETY PROTECTION PERFEDERAL, STATE, AND LOCAL REGULATIONS.RNGE:SECT:RMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 02/09/2223N4E24N.884795W26226RNTNWA01780 LOGAN AVE N.RENTON, WA 9805745FIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.com EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W T0+00 LMN MH 1156 11'41'11'11'11'11'11'38'NOTE:@ MANHOLE 1156, PLACE 480' OFNEW 24 COUNT FIBER IN EXISTINGCONDUIT TO MANHOLE 1154.T4+80 LMN MH 1154NOTE:@ MANHOLE 1154, PLACE 220' OFNEW 24 COUNT FIBER IN EXISTINGCONDUIT TO NEW CBO MEET POINT. EOP EOP R/W EOP EOP EOP EOP EOP EOP R/W NOTE:@ NEW CBO MEET POINT, NEW 90° CURVE FROM 4" CONDUITTO JOIN CBO CONDUIT THEN PLACE 150' OF NEW 24 COUNTFIBER THRU CONDUIT TO NEW CUSTOMER'S HANDHOLE 1.7+00 CBOMEET POINT R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W N. 8th STREET6' SIDEWALK6' SIDEWALK5' PLANTER5' PLANTERLOGAN AVE N.SHOULDER5' PLANTER30'26'6' SIDEWALK11'11'11'751PARCEL#088660004073513'80'SEE SHEET 530SPEEDLIMITMFP22001175 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSTOWN:GEO CODE:WC CLLI:NOTE:FOR UNDERGROUND ACTIVITY: TEST ANDVENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY, PLACE WARNING DEVICES AND WORKAREA PROTECTION AS REQUIRED, AND USEEYE AND HEAD SAFETY PROTECTION PERFEDERAL, STATE, AND LOCAL REGULATIONS.RNGE:SECT:RMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 02/09/2223N4E24N.884795W26226RNTNWA01780 LOGAN AVE N.RENTON, WA 9805755FIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.com EOP EOP EOP EOP EOP EOP TTSEE SHEET 4 EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 12+50 MPOP/DEMARC8+50 CBO HH 111+00 CBO HH 2780LOGAN AVE N.PARCEL#0886610010NOTE:@ CUSTOMER'S HANDHOLE 1,HANDHOLE 2 , PLACE 400' OF NEW24 COUNT FIBER IN EXISTINGCONDUIT TO NEW TO DEMARC.NOTE:@ CUSTOMER'S MPOP, TERMINATELRE30, 31-32 & LRE30, 39-40 IN FDP.LOGAN AVE N.SHOULDER5' PLANTER30'26'6' SIDEWALK11'11'11' R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 30SPEEDLIMITMFP22001175