June 27, 2017
Ms. Ann Fowler
Civil Engineer II
Renton City Hall
1055 S. Grady Way
Renton, WA 98057
RE: Senza Lakeview Final Plat
CPH Project No. 0139-15-001
City File No. LUA16-000165, ECF, PP, SM
Modification Request
Ms. Fowler,
This letter is written in request of a modification to the walls located on Lots 9 and 10 for the Senza Lakeview
project. Per Renton Municipal Code (RCM) 4-9-250D our request meets each of the six decision criteria as
outlined below.
a. Substantially implements the policy direction of the policies and objectives of the Comprehensive Plan
Land Use Element and the Community Design Element and the proposed modification is the minimum
adjustment necessary to implement these policies and objectives;
Response: The modification implements the policies and objectives of the Comprehensive Plan Land Use
Element and Community Design Element. The proposed walls are necessary in order to maintain a safe and
reliable slope and maximizing the usable space for the rear yards of Lots 9 and 10.
b. Will meet the objectives and safety, function, appearance, environmental protection and
maintainability intended by the Code requirements, based upon sound engineering judgment;
Response: The proposed wall meets height, safety, function, and appearance requirements as intended by
the City of Renton Code.
c. Will not be injurious to other property(ies) in the vicinity;
Response: The proposed wall meets City of Renton maximum height requirements and will not be injurious
to adjacent properties.
d. Conforms to the intent and purpose of the Code;
Response: The proposed wall conforms to the intent and purpose of the code.
e. Can be shown to be justified and required for the use and situation intended; and
Response: The proposed tiered wall design is required in order to maintain a safe and reliable slope while
limiting the disturbance to the rear yards of Lots 9 and 10.
f. Will not create adverse impacts to other property(ies) in the vicinity. (Ord. 4517, 5-8-1995; Ord.
4802, 10-25-1999; Ord. 5100, 11-1-2004; Ord. 5137, 4-25-2005; Ord. 5369, 4-14-2008)
Response: The proposed wall will not create adverse impacts to other properties in the vicinity.
Please contact me directly at (425) 285-2392 or by e-mail at jamie@cphconsultants.com if you have
questions or need any additional information to complete your review and approval of the project. Your
prompt response is appreciated. Thank you.
Senza Lakeview Preliminary Plat June 27, 2017
Modification Request Page 2 of 2
CPH No. 0139-15-001
Sincerely, CPH Consultants
Jamie B. Schroeder, PE
Vice President
Enclosures
Cc: copy to file
114 31 Wi llo ws R o ad NE , S u ite 120 | Re dmo nd, WA | 9805 2
www.c ph c o n su ltan ts.c o m | p: (425) 2 85 -2 39 0 | f: (425) 2 85 -2 38 9
Site Planning
Civil Engineering
Land Use Consulting
Project Management
June 27, 2017
Ms. Ann Fowler
Civil Engineer II
Renton City Hall
1055 S. Grady Way
Renton, WA 98057
RE: Senza Lakeview Final Plat
CPH Project No. 0139-15-001
City File No. LUA16-000165, ECF, PP, SM
Modification Request Addendum
Ms. Fowler,
This letter is written as an addendum to the retaining wall modification request for the tiered walls located on
Lots 9 and 10 for the Senza Lakeview project.
The 5‘ terraced wall sections on Lots 9 and 10 meet the 5’ minimum terrace width and 6’ maximum wall height
as outlined in the City of Renton “Development Regulations for Retaining Walls”. The ground slope is flat
immediately behind the wall for 1’, rises at a slope of 3:1 for a horizontal distance of 3’, then is flat again for
1’ immediately in front of the succeeding wall. This maintains the maximum required terrace width of 5’. See
the attached wall sections for clarification.
Please contact me directly at (425) 285-2392 or by e-mail at jamie@cphconsultants.com if you have
questions or need any additional information to complete your review and approval of the project. Your
prompt response is appreciated. Thank you.
Sincerely, CPH Consultants
Jamie B. Schroeder, PE
Vice President
Enclosures
Cc: copy to file
1
Bryce Bessette
From:Clark Close <CClose@Rentonwa.gov>
Sent:Tuesday, November 29, 2016 11:00 AM
To:Bryce Bessette
Cc:Jamie Schroeder; Levi Rowse; Ann Fowler
Subject:RE: Retaining Wall Modification Request
Bryce,
We would be supportive of a retaining wall modification for Senza Lakeview Plat under the following conditions:
1. Increased rear yard setbacks from the rear elevation to the lowest/first retaining wall.
2. The required level flat areas between the walls may be sloped provided the slope does not exceed 3 to 1 percent
slope or 33% to still allow for landscaping.
3. No wall to exceed 5 feet in height to allow for increased opportunities for maintenance.
Thanks,
Clark H. Close
Senior Planner
City of Renton
425‐430‐7289
From: Bryce Bessette [mailto:bryce@cphconsultants.com]
Sent: Tuesday, November 22, 2016 4:38 PM
To: Clark Close
Cc: Jamie Schroeder; Levi Rowse
Subject: Retaining Wall Modification Request
Good Afternoon Clark,
I am writing to request a modification to the retaining wall standards per RMC 4‐9‐250D for the Senza Lakeview project.
The “Development Regulations for Retaining Walls” handout has been used as the guideline for maximum wall heights,
setback and terraced requirements. Due to the steep grade of the existing site there are significant elevation differences
between adjacent lots for the finished site. Several locations require a significant amount of grading or a large number of
terraced walls that limit the functional area of the space. The 6 foot high terraced walls also pose maintenance issues
which may require the future homeowner to use a ladder or other method to access and maintain each of the multiple
terraces. A section view of the terraced wall sections are provided in the attached figures along with the plan view of the
terraced walls that follow the City of Renton standards.
In order to increase the functionality of the rear yards and limit the amount of retaining walls onsite we are requesting a
deviation to 1) increase the retaining wall height, and/or 2) omit the flat terrace requirement between retaining walls.
As seen from the figures, the retaining walls in question for lots 9 and 10 are interior walls that will not be seen by the
public and will only impact the lot owners in question. The proposed homes will block the rear yard walls from public
viewing and the modification requested will provide a better finished product for the future home owner. More
functional rear yard area and more accessible maintenance would benefit the future homeowner and will not be an
eyesore to the public.
2
Please review the alternate sections that we have provided in the redlines attached and respond with any comments or
questions you may have. Specifically we are hoping to get a read from the City to determine if a modification would be
supported by the City and if we should continue to pursue a modification through the formal process.
Thank you and look forward to your response.
Bryce Bessette, EIT
Design Engineer
CPH Consultants
11431 Willows Road NE, Suite 120
Redmond, WA 98052
main: (425) 285-2390
www.cphconsultants.com