June 6, 2016
Project No. 16007
Matthew Herrera
City of Renton
1055 S Grady Way
Renton, Washington 98057
Re: The Pines Preliminary Plat, PRE16-000049
Dear Mr. Herrera:
This letter is provided to formally request modifications from RMC 4-6-060(F)(2) and RMC 4-6-
060(H)(2). Specifically, the modification from RMC 4-6-060(F)(2) is the request to allow for the
reduction in pavement width and sidewalk width for Monroe Avenue NE (minor arterial).
Specifically, the modification from RMC 4-6-060(H)(2) is the request to allow use of a
hammerhead turnaround, in lieu of a cul-de-sac, on a dead end street that is greater than 300
feet in length.
RMC 4-6-060(F)(2) Background
Monroe Avenue NE is currently developed with approximately 44-feet of pavement and curb
and gutter on both sides.
Modification Requested
RMC 4-6-060, Street Standards, F. Public Street Right-Of-Way Design Standards: A minor
arterial requires 91-feet of right-of-way, 54-feet of pavement width, 8-feet of planter strip, and
sidewalk on both sides. The applicant is proposing to hold the existing curb line
(approximately 44-feet of pavement width) and provide an 8-foot planter strip and a 5-foot
sidewalk.
Per the City of Renton Modification Submittal Requirements, in order to approve a modification
request, the following six conditions must exist:
1. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and the
proposed modification is the minimum adjustment necessary to implement these policies and
objectives.
2. Will meet the objectives and safety, function, appearance, environmental protection and
maintainability intended by the Code requirements, based upon sound engineering judgment.
3. Will not be injurious to other property(ies) in the vicinity.
4. Conforms to the intent and purpose of the Code.
5. Can be shown to be justified and required for the use and situation
intended.
Matthew Herrera
June 6, 2016
Page 2 of 3
6. Will not create adverse impacts to other property(ies) in the vicinity.
Justification
1. The City’s goal is to maintain the existing curb and gutter location and maintain the
bicycle corridor along Monroe Avenue NE. Maintaining the existing curb will provide
approximately 22-feet from the existing centerline to the curb line. The intent of the 8-foot
sidewalk is to allow for the bicycle lane to be transferred to the sidewalk area to create a multi-
use path. As stated above, Monroe Avenue NE is a dedicated bicycle corridor, therefore, an
additional bicycle lane or multi-use path is not necessary. Please see attached email from
Clark Close.
2. The modification will meet the objectives and safety, function, appearance,
environmental protection and maintainability by the Code.
3. Approval of the modification request would allow for development of this plat to maintain
the existing curb line and would avoid the removal of neighboring properties curb/driveways.
4. As discussed above, the modification conforms to the intent and purpose of the Code.
5. The City has determined, per the pre-application notes, that there is no intent to widen
the Monroe Avenue NE corridor. Thus, it is not practical to widen such a minor portion of the
corridor.
6. Approval of the modification request would allow for development of this plat to maintain
the existing curb line and would avoid the removal of neighboring properties curb/driveways.
RMC 4-6-060(H)(2) Background
The Project is proposing a dead end street less than 500 feet in length from Monroe Avenue
NE, east.
Modification Requested
RMC 4-6-060, Street Standards, H. Dead End Streets: For dead end streets from 300’ to 500’
in length, a cul-de-sac is required. The applicant is proposing use of a hammerhead turn
around on a road that is 385 feet from the proposed curb line in Monroe Ave NE to the
centerline of the proposed hammerhead..
Per the City of Renton Modification Submittal Requirements, in order to approve a modification
request, the following six conditions must exist:
1. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and the
proposed modification is the minimum adjustment necessary to implement these policies and
objectives.
2. Will meet the objectives and safety, function, appearance, environmental protection and
maintainability intended by the Code requirements, based upon sound engineering judgment.
3. Will not be injurious to other property(ies) in the vicinity.
4. Conforms to the intent and purpose of the Code.
Matthew Herrera
June 6, 2016
Page 3 of 3
5. Can be shown to be justified and required for the use and situation intended.
6. Will not create adverse impacts to other property(ies) in the vicinity.
Justification
1. Providing a cul-de-sac turnaround with a right of way diameter of 110 feet is more than
50% of the total property width (property width is 216 feet) and greatly encumbers usable
space. The application of a cul-de-sac would better serve properties with greater dimensions
that allow for lot access around the circumference of the cul-de-sac and allow it be utilized to
its full potential. Approval of the modification request is the minimum modification to
accomplish the desired purpose.
2. The project proposes to terminate the proposed roadway with a hammerhead which is
an acceptable emergency vehicle turnaround. Additionally, the future homes in the entire plat
shall be required to be fire sprinklered.
3. Approval of the modification request would allow for development of this plat which
would be in line with the neighboring developments in size, magnitude and density. Granting
of this variance would not constitute special privilege inconsistent with projects in the vicinity
given that the cul-de-sac turnarounds in the immediate vicinity of the project are between 80
and 90 feet in diameter. The requirement for 110 feet in diameter encumbers the property
more significantly than any developments in the vicinity.
4. As discussed above, the modification conforms to the intent and purpose of the Code.
5. As discussed above, the required diameter size of the cul-de-sac is more than 50% of
the total property width. Therefore, it greatly encumbers the usable space. The hammerhead
still provides the necessary turnaround for fire.
6. Approval of the modification would not create adverse impacts to the adjacent
properties.
In addition, please see the attached letter and correspondence with Corey Thomas.
Thank you for your time and consideration in this matter. Should you have any questions or
request any clarifications, please do not hesitate to contact me.
Sincerely yours,
D. R. STRONG Consulting Engineers Inc.
Yoshio L. Piediscalzi, P.E.
Project Engineer
YLP/lcs
R:\2016\0\16007\Correspondence\Letters\out\L16007_160606_Matthew Herrera.docx
1
SharedInformation
From:Clark Close <CClose@Rentonwa.gov>
Sent:Thursday, February 11, 2016 1:40 PM
To:Maher Joudi
Subject:PRE16-000049 Stinde Preliminary Plat Preapp
Attachments:16-000049 (R-8 Stinde Pre Plat) Meeting Summary.pdf
Maher,
Here is some follow-up information from your plan reviewer regarding moving the curb rather than maintaining the curb
at its current location.
Given the corridor is a dedicated bicycle corridor, transportation is not willing to allow relocation of the curb. However,
they would support a modification to reduce the sidewalk from 8-ft to 5-ft, which would only require 3.5-feet of
dedication in lieu of 6.5-feet.
Thanks,
Clark H. Close
City of Renton – Current Planning
Senior Planner
Tel: 425-430-7289
Engineers Surveyors Planners
620 7th Ave Kirkland, WA 98033-5565
Phone: (425) 827-3063
Fax: (425) 827-2423
Toll Free: (800) 962-1402
www.drstrong.com
March 22, 2016
Project No. 16007
Corey Thomas
City of Renton
1055 S Grady Way
Renton, Washington 98057
Re: Stinde Preliminary Plat, PRE16-000049
Dear Mr. Thomas:
This letter is provided to formally request modification from RMC 4-6-060(H)(2). Specifically,
the request to allow use of a hammerhead turnaround, in lieu of a cul-de-sac, on a dead end
street that is greater than 300 feet in length.
Background
The Project is proposing a dead end street less than 500 feet in length from Monroe Avenue
South, east.
Variance Requested
RMC 4-6-060, Street Standards, H. Dead End Streets: For dead end streets from 300’ to 500’
in length, a cul-de-sac is required. The applicant is proposing use of a hammerhead turn
around on a road that is 385 feet from the proposed curb line in Monroe Ave NE to the
centerline of the proposed hammerhead.
Per the City of Renton Variance Submittal Requirements, in order to approve a variance
request, the following four conditions must exist:
1. The applicant suffers undue hardship and the variance is necessary because of special
circumstances applicable to the subject property, including size, shape, topography, and
location or surroundings of the subject property; and the strict application of the Building and
Zoning code is found to deprive subject property owner of rights and privileges enjoyed by
other property owners in the vicinity and under identical classification.
2. The granting of the variance will not be materially detrimental to the public welfare or
injurious to the property or improvements in the vicinity and zone in which subject property is
situated.
3. Approval shall not constitute a grant of special privilege inconsistent with the limitation
upon uses of other properties in the vicinity and zone in which the subject property is situated.
4. The approval, as determined the Reviewing Official, is the minimum variance that will
accomplish the desired purpose.
Corey Thomas
March 22, 2016
Page 2 of 2
Justification
1. Providing a cul-de-sac turnaround with a right of way diameter of 110 feet is more than
50% of the total property width (property width is 216 feet) and greatly encumbers usable
space. The application of a cul-de-sac would better serve properties with greater dimensions
that allow for lot access around the circumference of the cul-de-sac and allow it be utilized to
it!s full potential.
2. The project proposes to terminate the proposed roadway with a hammerhead which is
an acceptable emergency vehicle turnaround. Additionally, the hammerhead will meet the
required dimensional standards and be adequately signed, "No Parking#.
3. Approval of the variance request would allow for development of this plat which would
be in line with the neighboring developments in size, magnitude and density. Granting of this
variance would not constitute special privilege inconsistent with projects in the vicinity given
that the cul-de-sac turnarounds in the immediate vicinity of the project are between 80 and 90
feet in diameter. The requirement for 110 feet in diameter encumbers the property more
significantly than any developments in the vicinity.
4. Approval of the variance request is the minimum variance to accomplish the desired
purpose.
Thank you for your time and consideration in this matter. Should you have any questions or
request any clarifications, please do not hesitate to contact me.
Sincerely yours,
D. R. STRONG Consulting Engineers Inc.
Maher A. Joudi, P.E.
Principal, Sr. Vice President
Director of Engineering
MAJ/lcs
R:\2016\0\16007\Correspondence\Letters\out\L16007_160322_CoryThomas.docx
1
SharedInformation
From:Corey W Thomas <CThomas@Rentonwa.gov>
Sent:Wednesday, April 06, 2016 4:18 PM
To:Maher Joudi
Cc:Jamie Waltier; Chris Burrus (CBurrus@harbourhomes.com); Clark Close
Subject:RE: Stinde Preliminary Plat Hammerhead Variance Request PRE16-000049
Attachments:turnaround.pdf
Maher,
The fire chief has approved your variance request with the condition that all future homes in the entire plat shall require
an approved residential fire sprinkler system. The placement and configuration of the hammerhead turnaround shall be
a mutually agreed upon location to be determined by the planning and fire department. The hammerhead shall meet all
fire department specifications, see attached above. Contact Clark Close for exact placement of the hammerhead.
Corey Thomas
Fire Plans Reviewer/Inspector III
City of Renton Fire & Emergency Services Department
COMMUNITY RISK REDUCTION
Phone: 425-430-7024 Fax: 425-430-7022
Email: cthomas@rentonwa.gov
1055 South Grady Way
Renton, WA 98057-3232
Professionalism Ÿ Integrity Ÿ Leadership Ÿ Accountability Ÿ Respect
From: Maher Joudi [mailto:maher.joudi@drstrong.com]
Sent: Tuesday, March 22, 2016 18:33
To: Corey W Thomas
Cc: Jamie Waltier; Chris Burrus (CBurrus@harbourhomes.com)
Subject: Stinde Preliminary Plat Hammerhead Variance Request PRE16-000049
Hi Corey,
We are moving forward on this project and per your comments at the pre app, I am emailing a letter requesting
allowance of a hammerhead on a dead end road longer than 300’.
Please see attached.
Thanks Corey.
D.R. STRONG
Consulting
Engineers Inc.
CIVIL ENGINEERS PLANNERS
Maher A. Joudi, P.E.
Principal, Sr. Vice President
Director of Engineering
620 7th Avenue
Kirkland, WA 98033
Office: (425) 827-3063
2
Please Note:
The information in this E-mail message, and any files transmitted with it, is confidential and may be legally privileged. It is intended only for
the use of the individual(s) named above. If you are the intended recipient, be aware that your use of any confidential or personal information
may be restricted by state and federal privacy laws. If you, the reader of this message, are not the intended recipient, you are hereby notified that you should not further disseminate, distribute, or forward this E-mail message. If you have received this E-mail in error, please notify the sender and delete the material from any computer. Thank you.
SURVEYORS Cell: (206) 948-7002
Fax: (425) 827-2423