Loading...
HomeMy WebLinkAbout16013 Crowel,Nguyen ADU, 756 Orcas Ave NE-SUB1.rvt - Sheet_ A201 - MAIN FLOORSDSDCD 1 2 A B Mstr Bdrm CARPET En-Suite TILE Pwdr HDWD Garage CONCRETE Kitchen HDWD Great Room HDWD 38'-6" 4'-0"15'-0"19'-6" R&S R&SWC WC VANITY VANITYSTACKED W/D 36" RANGE DW33'-6"10'-0"6'-0"15'-0"2'-6"1'-0"8'-3" R.O.9"1'-0"4'-0"1'-0"4'-0"8'-0"3'-0"24'-0"14'-6"33'-6"10'-0"23'-6"8'-1"1'-11"3'-0"4'-0"3'-9"12'-9"3'-9"8'-0"3'-3"2'-5 1/2"5'-2 1/2"8'-0"3'-10" 1 A701 1 A701 2 A701 2 A701 38'-6" C2 8'-0" x 2'-0" A1 8'-0" x 6'-0" C1 4'-0" x 2'-0" A2 8'-0" x 6'-0" A3 8'-0" x 6'-0" B1 4'-0" x 5'-0" 342 8'-0"x 8'-0" 335 2'-8"x 8'-0" 341 2'-8"x 8'-0" 336 2'-4"x 8'-0" 334 2'-4"x 8'-0" 347 3'-0"x 8'-0" 338 2'-6"x 8'-0" 337 2'-4"x 8'-0" 340 3'-0"x 8'-0" 339 2'-4"x 8'-0" 343 3'-0"x 8'-0" 4 i101 1 i101 C3 4'-0" x 1'-0" Walk-In CARPET Entry Closet HDWD D101 12 D101 12 SCALE 24X36: PROJECT NO: ISSUE DATE: DRAWN BY: CHECKED BY: * NOTE:11X17 SETS ARE REDUCED 50%; SCALE DRAWINGS ACCORDINGLY. 1/4" = 1'-0"11/10/2016 1:55:06PMZ:\2016\16013 Sq1, Crowel,Nguyen Residence, 756 Orcas Ave NE\05 Construction Docs\16013 Crowel,Nguyen ADU, 756 Orcas Ave NE-SUB1.rvtMAIN FLOOR 16013 2016/10/01 SPM A201 CONDITIONAL USE PERMIT SET756 Ocas Ave NEChecker AREA SCHEDULE... NAME AREA MAIN FLOOR 797 SF 797 SF GARAGE 200 SF Patio 192 SF 392 SF 1189 SF SEE "TYPICAL BUILDING MATERIALS" LIST ON THE ELEVATION SHEET(s). 1.SEE SHEET A002 FOR GENERAL CONSTRUCTION SPECIFICATIONS. 3. 2.SEE BUILDING ELEVATIONS FOR WINDOW OPERATION. GENERAL PLAN NOTES: FOR THE SYMBOLS & LEGEND SEE SHEET A000.4. SEE STRUCTURAL SHEETS FOR FOR SHEARWALL DESIGNATIONS & HOLDDOWNS AND SHEET S1 FOR SHEARWALL DETAILS/ SCHEDULE. 5. FLOOR PLAN KEYNOTES: P-1 GARAGE/HOUSE OCCUPANCY SEPARATION. PER IRC R302.6 a) 1/2" GYP. AT GARAGE SIDE BETWEEN RESIDENCE AND ATTIC. b) 5/8" TYPE 'X' GYP SEPARATING HABITABLE ROOMS ABOVE. c) 1/2" GYP. AT WALLS SUPPORTING HABITABLE ROOMS ABOVE." P-2 DOOR BETWEEN GARAGE AND HOUSE SHALL BE, 1 3/8" THICK SOLID WOOD DOOR OR 20 MIN. F.R. DOOR. PER IRC SECTION R302.5 P-3 STAIR ASSEMBLY: PER IRC SECTION R311.7" a) WIDTH 36" MIN.; HEADROOM 6'-8" MIN. b) RISER 7-3/4" MAX.; TREAD 10" MIN. c) TOP OF HANDRAIL AT 34" MIN. AND 38" MAX ABOVE TREAD NOSING d) HANDRAIL WIDTH 1-1/4" MIN. AND 2" MAX. e) INSTALL FIRE BLOCKING IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. f) COVER USABLE SPACE UNDER STAIR WITH 1/2" GYP." P-4 SAFETY GLAZING PER IRC SECTION R308.4 P-5 EGRESS WINDOW PER IRC SECTION R310. PROVIDE MIN NET CLEARANCE OF 5 SF AT GRADE FLOOR OPENINGS AND 5.7 SF ABOVE. MIN SILL HEIGHT TO BE 44" A.F.F. P-6 IGNITERS: A) FOR GAS FIRED APPLIANCES IN GARAGE TO BE 18" MIN ABOVE TOP OF SLAB, PROVIDE (2) LAYERS OF FLOOR SHEATHING OVER FRAMING.. PER IRC SECTION G2408. B) HEAT-PRODUCING EQUIPMENT AND APPLIANCES SHALL BE INSTALLED TO MAINTAIN THE REQUIRED CLEARANCES TO COMBUSTIBLE CONSTRUCTION AS SPECIFIED IN THE LISTING AND MANUFACTURER’S INSTRUCTIONS. PER IRC G2408.5 P-7 COVER WALLS ADJACENT TO TUBS AND SHOWERS WITH NONABSORBENT MATERIAL TO 72" ABOVE DRAIN INLETS. PER IRC SECTION R307.2. FOR GROUND FLR WASTE OPENING REQ SEE UPC NOTES ON SHT A001 P-8 HIGH EFFICIENCY GAS FURNACE, SIZE PER WSEC PRESCRIPTIVE ENERGY CODE COMPLIANCE FORMS. a) PROVIDE DUCT LEAKAGE, SEALING & TESTING PER WSEC 502 & 503. b) THERMOSTAT PER WSEC 503.8. c) SEE WSEC NOTES ON SHEET A001 P-9 7-3/4 MAX. RISER WITH 10" MIN. TREAD DEPTH. IF MORE THAN (4) RISERS HANDRAIL REQUIRED PER IRC SECTION R311.7.7. a) PROVIDE 36"x36" MIN. LANDING AT EXTERIOR DOORS PER IRC SECTION R311.3 P-10 PROVIDE CRAWL SPACE ACCESS, MIN. 18" X 24" UNOBSTRUCTED ACCESS. PER IRC SECTION R408.4 P-11 PROVIDE ATTIC ACCESS, MIN. 22" X 30" WITH 30" MIN. HEADROOM AT UNOBSTRUCTED READILY ACCESSIBLE OPENING. PER IRC SECTION R807.1 P-12 2" RECESS FOR REFRIGERATOR P-13 FIREPLACE ASSEMBLY. PER IRC CHAPTER 10. a) FACTORY-BUILT FIREPLACES TO BE INSTALLED PER MFR. PER IRC SECTION R1004. b). INSTALL MASONRY FIREPLACES PER IRC SECTION R1003. c). HEARTH SHALL CONFORM TO IRC REQUIREMENTS. P-14 SEE SITE PLAN FOR EXTENT OF WALKS AND DRIVEWAYS. P-15 36" MIN. GUARDRAIL. AT STAIRS SLOPES AT 36" ABOVE STAIR NOSINGS. PER SEE IRC SECTION 312 P-16 B' VENT FOR MECHANICAL. 1" CLEARANCE ALL SIDES. P-17 2x6 WALL FOR PLUMBING / HVAC. P-18 A PERMANENT CERTIFICATE SHALL BE POSTED WITHIN 36" OF THE ELECTRICAL DISTRIBUTION PANEL. SEE WSEC SECTION 105 ON SHEET A001 P-19 3" DIA GALV BOLLARD OR EQ PER G2408.3 & M1307.3.1 No.DateDescription 12 4 12 412 4 12 2 12 4 O.H. PER PLAN6"2"1"6X10 OUTRIGGER 5/4X6 TRIM AT JAMBS 2X8 TRIM AT HEAD 2X6 TRIM AT SILL WINDOW PER PLANS 4X6 2X6 4X624"16"1"3/4"Level 1 524.00 T.O. PL Lvl1 534.00 T.O. ROOF 538.16 ABE 522.25 1 2 10'-0"69 TPO ROOFINGCOMP. ROOFING CORNER TRIM 3'-9"4'-3"Level 1 524.00 T.O. PL Lvl1 534.00 T.O. ROOF 538.16 ABE 522.25 A B 10'-0"62 60 342 8'-0"x 8'-0" COMP. ROOFING CORNER TRIM OUTRIGGERS 14'-1 7/8" 24' MAX8'-0"Level 1 524.00 T.O. PL Lvl1 534.00 T.O. ROOF 538.16 ABE 522.25 AB 10'-0"B1 A3343 3'-0"x 8'-0" 341 2'-8"x 8'-0"CORNER TRIM COMP. ROOFING TPO ROOFING 8'-0"Level 1 524.00 T.O. PL Lvl1 534.00 T.O. ROOF 538.16 ABE 522.25 12 15.91'10'-0"A2 340 3'-0"x 8'-0" C2 8'-0"6" HORZ SIDING CORNER TRIM COMP. ROOFING OUTRIGGER SCALE 24X36: PROJECT NO: ISSUE DATE: DRAWN BY: CHECKED BY: * NOTE:11X17 SETS ARE REDUCED 50%; SCALE DRAWINGS ACCORDINGLY. As indicated 11/10/2016 1:55:07PMZ:\2016\16013 Sq1, Crowel,Nguyen Residence, 756 Orcas Ave NE\05 Construction Docs\16013 Crowel,Nguyen ADU, 756 Orcas Ave NE-SUB1.rvtELEVATIONS 16013 2016/10/01 SPM A601 CONDITIONAL USE PERMIT SET756 Ocas Ave NEChecker TYPICAL BUILDING MATERIALS: EXTERIOR WALL CONSTRUCTION ROOF CONSTRUCTION SOFFIT: BUILDING PAPER: SIDING MATERIAL: GWB: INSULATION: FRAMING: SHEATHING: GWB: BUILDING PAPER: ROOFING: INSULATION: FRAMING: SHEATHING: FLOOR CONSTRUCTION TRIM CORNER BOARDS: FASCIA: WINDOW: (WITH NO BRICK MOLD) OUTSIDE: INSIDE: 5/4x4 WRAP FRAMING: SOFFIT: INSULATION: SUBFLOOR: FLOORING: ASPHALT SHINGLES 15# BUILDING PAPER PER SHEARWALL SCHEDULE PER PLANS R-49 BLOWN-IN (R-38 VAULTED) 1/2" RESAWN PLYWOOD 5/8" GWB PER ELEVATIONS 15# BUILDING PAPER PER SHEARWALL SCHEDULE 2x6 STUDS AT 16" oc U.N.O. R-21 BATT w/ INTEGRAL VAPOR BARRIER 1/2" GWB FINISH PER PLANS 3/4" T&G (PLYWOOD, COMPLY OR EQUAL) PER PLANS R-38 BATT 1/2" RESAWN PLYWOOD 2x2 2x4, 2x3 2x8 w/ 2x3 (PER DETAILS) U.N.O. SCALE: 3/4" = 1'-0"C 6X OUTRIGGER SCALE: 1/2" = 1'-0"F WINDOW TRIM II 1. INSTALL APPROVED CORROSION-RESISTANT FLASHING, TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS PER R708.3. SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: a. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. c. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. e. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME CONSTRUCTION. f. AT WALL AND ROOF INTERSECTIONS. g. AT BUILT-IN GUTTERS. ELEVATION NOTES: SCALE: 3/4" = 1'-0"D 4x KNEE BRACE No.DateDescriptionSCALE: 1/4" = 1'-0"1 SOUTH ELEVATION SCALE: 1/4" = 1'-0"2 WEST ELEVATION SCALE: 1/4" = 1'-0"3 EAST ELEVATION SCALE: 1/4" = 1'-0"4 NORTH ELEVATION