Loading...
HomeMy WebLinkAboutPrimary House B16003589 SUB2 16013 CrowelNguyen Residence Elevations_2016113012 2 12 0.25 Level 1 0.00 Level 2 11.00 Level 2 11.00 T.O. PL Lvl2 20.08 T.O. PL Lvl2 20.08 T.O. PL Lvl1 10.00 B.O. JSTS -0.83 MAX T.O. ROOF 28.02 ABE -1.99 1 2 B.O. Garage Door -2.50 C20 6'-0" x 6'-0" 701 16'-0"x 10'-0" C10 3'-0" x 3'-0" 4:12 4:12 4:12 100 6'-0"x 8'-0" A602 B A602 A24'6'8'-0"B4 8'-0" x 4'-6"B3 6'-6" x 6'-0" B1 6'-6" x 6'-0" B5 8'-0" x 6'-0" B2 8'-0" x 6'-0" C7 4'-0" x 2'-0" C15 4'-0" x 2'-0"12'-6"MAX T.O. PLATE 22.02 22.07'10'-0"9'-1"8'-0"8'-0"702 16'-0"x 10'-0" ASPHALT SHINGLES 8" HORZ SIDING 4" HORZ SIDING CORNER TRIM CORNER TRIM 8" HORZ SIDING HARDIE 'SMOOTH' PANEL w/ FRY REGLET FLASHING CEDAR T&G SIDING TPO ROOFING CONCRETE PORCH & STEPS FASCIA AND GUTTER 2x10 TRIM 1 1 Level 1 0.00 Level 2 11.00 T.O. PL Lvl2 20.08 T.O. PL Lvl1 10.00 F G B.O. Garage Door -2.50 A2 6'-0" x 6'-0" C5 4'-0" x 1'-0" C6 4'-0" x 1'-0" C8 4'-0" x 6'-0" C9 4'-0" x 6'-0" C17 4'-0" x 6'-0" 1 A701 1 A701 ASPHALT SHINGLES 4:12 C18 4'-0" x 6'-0" C23 6'-0" x 6'-0" A6 6'-0" x 6'-0" C16 4'-0" x 2'-0" 3 A702 TPO ROOFING HARDIE 'SMOOTH' PANEL w/ FRY REGLET FLASHING8" HORZ SIDING HARDIE 'SMOOTH' PANEL FASCIA AND GUTTER 8" HORZ SIDINGCORNER TRIM A602 B HARDIE 'SMOOTH' PANEL w/ FRY REGLET FLASHING 1 1 SCALE 24X36: PROJECT NO: ISSUE DATE: DRAWN BY: CHECKED BY: * NOTE:11X17 SETS ARE REDUCED 50%; SCALE DRAWINGS ACCORDINGLY. 1/4" = 1'-0"9/29/2016 2:06:14 PMELEVATIONS 16013 2016/09/29 SPM A601 PERMIT SETCrowell/Nguyen Residence756 Orcas Ave NESPM TYPICAL BUILDING MATERIALS: EXTERIOR WALL CONSTRUCTIONROOF CONSTRUCTION SOFFIT: BUILDING PAPER: SIDING MATERIAL: GWB: INSULATION: FRAMING: SHEATHING: GWB: BUILDING PAPER: ROOFING: INSULATION: FRAMING: SHEATHING: FLOOR CONSTRUCTION TRIM CORNER BOARDS: FASCIA: WINDOW: (WITH NO BRICK MOLD) OUTSIDE: INSIDE: 5/4x4 WRAP FRAMING: SOFFIT: INSULATION: SUBFLOOR: FLOORING:ASPHALT SHINGLES 15# BUILDING PAPER PER SHEARWALL SCHEDULE PER PLANS R-49 BLOWN-IN (R-38 VAULTED) 1/2" RESAWN PLYWOOD 5/8" GWB PER ELEVATIONS 15# BUILDING PAPER PER SHEARWALL SCHEDULE 2x6 STUDS AT 16" oc U.N.O. R-21 BATT w/ INTEGRAL VAPOR BARRIER 1/2" GWB FINISH PER PLANS 3/4" T&G (PLYWOOD, COMPLY OR EQUAL) PER PLANS R-38 BATT 1/2" RESAWN PLYWOOD 2x2 2x4, 2x3 2x8 w/ 2x3 (PER DETAILS) U.N.O. 1. INSTALL APPROVED CORROSION-RESISTANT FLASHING, TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS PER R708.3. SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: a. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. c. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. e. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME CONSTRUCTION. f. AT WALL AND ROOF INTERSECTIONS. g. AT BUILT-IN GUTTERS. ELEVATION NOTES: SCALE: 1/4" = 1'-0"1 FRONT ELEVATION SCALE: 1/4" = 1'-0"2 LEFT ELEVATION No.DateDescription120160929CITY COMMENTS 12 4 12 2 12 4 5/4X6 TRIM AT JAMBS 2X8 TRIM AT HEAD 2X6 TRIM AT SILL WINDOW PER PLANS O.H. PER PLAN6"2"1"6X10 OUTRIGGER Level 1 0.00 Level 2 11.00 T.O. PL Lvl2 20.08 T.O. PL Lvl1 10.00 ABE -1.99 12 B.O. Garage Door -2.50 A5 6'-0" x 6'-0" C14 4'-0" x 2'-0" A4 6'-0" x 6'-0" C1 3'-0" x 3'-0" D1 3'-0" x 4'-0"C13 3'-0" x 6'-0" C21 6'-0" x 6'-0" C4 3'-0" x 6'-0" C3 3'-0" x 6'-0" C12 3'-0" x 6'-0" 601 8'-0"x 8'-0" A1 5'-0" x 5'-0" 1 A702 1 A702 4:12 4:12 C2 3'-0" x 3'-0" 2 A701 8" HORZ SIDING ASPHALT SHINGLES FASCIA AND GUTTER HARDIE 'SMOOTH' PANEL CORNER TRIM E1 4'-0" x 4'-0" C19 4'-0" x 6'-0" D2 3'-0" x 4'-0" 8" HORZ SIDING CORNER TRIM A602 B 1 1 Level 1 0.00 Level 2 11.00 T.O. PL Lvl1 10.00 FG B.O. Garage Door -2.50 C11 3'-0" x 3'-0" A3 6'-0" x 6'-0" 1 A701 1 A701 4:12 4:12 4" HORZ SIDING HARDIE 'SMOOTH' PANEL w/ FRY REGLET FLASHING 8" HORZ SIDING ASPHALT SHINGLES 2x10 TRIM C22 6'-0" x 6'-0" 3 A702 CORNER TRIM HARDIE 'SMOOTH' PANEL BRUSHED CONCRETE HARDIE 'SMOOTH' PANEL w/ FRY REGLET FLASHING CEDAR T&G SIDING 1 SCALE 24X36: PROJECT NO: ISSUE DATE: DRAWN BY: CHECKED BY: * NOTE:11X17 SETS ARE REDUCED 50%; SCALE DRAWINGS ACCORDINGLY. As indicated 9/29/2016 2:06:16 PMELEVATIONS 16013 2016/09/29 SPM A602 PERMIT SETCrowell/Nguyen Residence756 Orcas Ave NESPM SCALE: 1/2" = 1'-0"B WINDOW TRIM II SCALE: 3/4" = 1'-0"A 6X OUTRIGGER SCALE: 1/4" = 1'-0"8 REAR ELEVATION SCALE: 1/4" = 1'-0"9 RIGHT ELEVATION TYPICAL BUILDING MATERIALS: EXTERIOR WALL CONSTRUCTIONROOF CONSTRUCTION SOFFIT: BUILDING PAPER: SIDING MATERIAL: GWB: INSULATION: FRAMING: SHEATHING: GWB: BUILDING PAPER: ROOFING: INSULATION: FRAMING: SHEATHING: FLOOR CONSTRUCTION TRIM CORNER BOARDS: FASCIA: WINDOW: (WITH NO BRICK MOLD) OUTSIDE: INSIDE: 5/4x4 WRAP FRAMING: SOFFIT: INSULATION: SUBFLOOR: FLOORING:ASPHALT SHINGLES 15# BUILDING PAPER PER SHEARWALL SCHEDULE PER PLANS R-49 BLOWN-IN (R-38 VAULTED) 1/2" RESAWN PLYWOOD 5/8" GWB PER ELEVATIONS 15# BUILDING PAPER PER SHEARWALL SCHEDULE 2x6 STUDS AT 16" oc U.N.O. R-21 BATT w/ INTEGRAL VAPOR BARRIER 1/2" GWB FINISH PER PLANS 3/4" T&G (PLYWOOD, COMPLY OR EQUAL) PER PLANS R-38 BATT 1/2" RESAWN PLYWOOD 2x2 2x4, 2x3 2x8 w/ 2x3 (PER DETAILS) U.N.O. 1. INSTALL APPROVED CORROSION-RESISTANT FLASHING, TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS PER R708.3. SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: a. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. c. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. e. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME CONSTRUCTION. f. AT WALL AND ROOF INTERSECTIONS. g. AT BUILT-IN GUTTERS. ELEVATION NOTES:No.DateDescription120160929CITY COMMENTS