HomeMy WebLinkAboutPrimary House B16003589 SUB2 16013 CrowelNguyen Residence Elevations_2016113012
2
12
0.25
Level 1
0.00
Level 2
11.00
Level 2
11.00
T.O. PL Lvl2
20.08
T.O. PL Lvl2
20.08
T.O. PL Lvl1
10.00
B.O. JSTS
-0.83
MAX T.O. ROOF
28.02
ABE
-1.99
1 2
B.O. Garage Door
-2.50
C20
6'-0" x 6'-0"
701
16'-0"x 10'-0"
C10
3'-0" x 3'-0"
4:12
4:12
4:12
100
6'-0"x 8'-0"
A602
B
A602
A24'6'8'-0"B4
8'-0" x 4'-6"B3
6'-6" x 6'-0"
B1
6'-6" x 6'-0"
B5
8'-0" x 6'-0"
B2
8'-0" x 6'-0"
C7
4'-0" x 2'-0"
C15
4'-0" x 2'-0"12'-6"MAX T.O. PLATE
22.02
22.07'10'-0"9'-1"8'-0"8'-0"702
16'-0"x 10'-0"
ASPHALT SHINGLES
8" HORZ SIDING
4" HORZ SIDING
CORNER TRIM
CORNER TRIM
8" HORZ SIDING
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING CEDAR T&G SIDING
TPO ROOFING
CONCRETE PORCH &
STEPS
FASCIA AND GUTTER
2x10 TRIM
1
1
Level 1
0.00
Level 2
11.00
T.O. PL Lvl2
20.08
T.O. PL Lvl1
10.00
F
G
B.O. Garage Door
-2.50
A2
6'-0" x 6'-0"
C5
4'-0" x 1'-0"
C6
4'-0" x 1'-0"
C8
4'-0" x 6'-0"
C9
4'-0" x 6'-0"
C17
4'-0" x 6'-0"
1
A701
1
A701
ASPHALT SHINGLES
4:12
C18
4'-0" x 6'-0"
C23
6'-0" x 6'-0"
A6
6'-0" x 6'-0"
C16
4'-0" x 2'-0"
3
A702
TPO ROOFING
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING8" HORZ SIDING
HARDIE 'SMOOTH' PANEL
FASCIA AND GUTTER
8" HORZ SIDINGCORNER TRIM
A602
B
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING
1
1
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY.
1/4" = 1'-0"9/29/2016 2:06:14 PMELEVATIONS
16013
2016/09/29
SPM
A601
PERMIT SETCrowell/Nguyen Residence756 Orcas Ave NESPM
TYPICAL BUILDING MATERIALS:
EXTERIOR WALL CONSTRUCTIONROOF CONSTRUCTION
SOFFIT:
BUILDING PAPER:
SIDING MATERIAL:
GWB:
INSULATION:
FRAMING:
SHEATHING:
GWB:
BUILDING PAPER:
ROOFING:
INSULATION:
FRAMING:
SHEATHING:
FLOOR CONSTRUCTION TRIM
CORNER BOARDS:
FASCIA:
WINDOW:
(WITH NO BRICK MOLD)
OUTSIDE:
INSIDE:
5/4x4 WRAP
FRAMING:
SOFFIT:
INSULATION:
SUBFLOOR:
FLOORING:ASPHALT SHINGLES
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
PER PLANS
R-49 BLOWN-IN (R-38 VAULTED)
1/2" RESAWN PLYWOOD
5/8" GWB
PER ELEVATIONS
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
2x6 STUDS AT 16" oc U.N.O.
R-21 BATT w/ INTEGRAL VAPOR
BARRIER
1/2" GWB
FINISH PER PLANS
3/4" T&G (PLYWOOD, COMPLY OR EQUAL)
PER PLANS
R-38 BATT
1/2" RESAWN PLYWOOD
2x2
2x4, 2x3
2x8 w/ 2x3 (PER DETAILS) U.N.O.
1. INSTALL APPROVED CORROSION-RESISTANT FLASHING, TO PREVENT
ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER
TO THE BUILDING STRUCTURAL FRAMING COMPONENTS PER R708.3.
SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH
AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE
EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING
LOCATIONS:
a. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR
WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE
OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE
BARRIER FOR SUBSEQUENT DRAINAGE.
b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY
CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH
PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS.
c. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL
COPINGS AND SILLS.
d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM.
e. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A
WALL OR FLOOR ASSEMBLY OF WOOD-FRAME CONSTRUCTION.
f. AT WALL AND ROOF INTERSECTIONS.
g. AT BUILT-IN GUTTERS.
ELEVATION NOTES:
SCALE: 1/4" = 1'-0"1 FRONT ELEVATION
SCALE: 1/4" = 1'-0"2 LEFT ELEVATION No.DateDescription120160929CITY COMMENTS
12
4
12
2
12
4
5/4X6 TRIM AT JAMBS
2X8 TRIM AT HEAD
2X6 TRIM AT SILL
WINDOW
PER
PLANS
O.H. PER PLAN6"2"1"6X10 OUTRIGGER
Level 1
0.00
Level 2
11.00
T.O. PL Lvl2
20.08
T.O. PL Lvl1
10.00
ABE
-1.99
12
B.O. Garage Door
-2.50
A5
6'-0" x 6'-0"
C14
4'-0" x 2'-0"
A4
6'-0" x 6'-0"
C1
3'-0" x 3'-0"
D1
3'-0" x 4'-0"C13
3'-0" x 6'-0"
C21
6'-0" x 6'-0"
C4
3'-0" x 6'-0"
C3
3'-0" x 6'-0"
C12
3'-0" x 6'-0"
601
8'-0"x 8'-0"
A1
5'-0" x 5'-0"
1
A702
1
A702
4:12
4:12
C2
3'-0" x 3'-0"
2
A701
8" HORZ SIDING
ASPHALT SHINGLES
FASCIA AND GUTTER
HARDIE 'SMOOTH' PANEL
CORNER TRIM
E1
4'-0" x 4'-0"
C19
4'-0" x 6'-0"
D2
3'-0" x 4'-0"
8" HORZ SIDING
CORNER TRIM
A602
B
1
1
Level 1
0.00
Level 2
11.00
T.O. PL Lvl1
10.00
FG
B.O. Garage Door
-2.50
C11
3'-0" x 3'-0"
A3
6'-0" x 6'-0"
1
A701
1
A701
4:12
4:12
4" HORZ SIDING
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING
8" HORZ SIDING
ASPHALT SHINGLES
2x10 TRIM
C22
6'-0" x 6'-0"
3
A702
CORNER TRIM
HARDIE 'SMOOTH' PANEL
BRUSHED CONCRETE
HARDIE 'SMOOTH' PANEL w/
FRY REGLET FLASHING
CEDAR T&G SIDING
1
SCALE 24X36:
PROJECT NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
* NOTE:11X17 SETS ARE
REDUCED 50%; SCALE
DRAWINGS ACCORDINGLY.
As indicated
9/29/2016 2:06:16 PMELEVATIONS
16013
2016/09/29
SPM
A602
PERMIT SETCrowell/Nguyen Residence756 Orcas Ave NESPM
SCALE: 1/2" = 1'-0"B WINDOW TRIM II
SCALE: 3/4" = 1'-0"A 6X OUTRIGGER
SCALE: 1/4" = 1'-0"8 REAR ELEVATION
SCALE: 1/4" = 1'-0"9 RIGHT ELEVATION
TYPICAL BUILDING MATERIALS:
EXTERIOR WALL CONSTRUCTIONROOF CONSTRUCTION
SOFFIT:
BUILDING PAPER:
SIDING MATERIAL:
GWB:
INSULATION:
FRAMING:
SHEATHING:
GWB:
BUILDING PAPER:
ROOFING:
INSULATION:
FRAMING:
SHEATHING:
FLOOR CONSTRUCTION TRIM
CORNER BOARDS:
FASCIA:
WINDOW:
(WITH NO BRICK MOLD)
OUTSIDE:
INSIDE:
5/4x4 WRAP
FRAMING:
SOFFIT:
INSULATION:
SUBFLOOR:
FLOORING:ASPHALT SHINGLES
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
PER PLANS
R-49 BLOWN-IN (R-38 VAULTED)
1/2" RESAWN PLYWOOD
5/8" GWB
PER ELEVATIONS
15# BUILDING PAPER
PER SHEARWALL SCHEDULE
2x6 STUDS AT 16" oc U.N.O.
R-21 BATT w/ INTEGRAL VAPOR
BARRIER
1/2" GWB
FINISH PER PLANS
3/4" T&G (PLYWOOD, COMPLY OR EQUAL)
PER PLANS
R-38 BATT
1/2" RESAWN PLYWOOD
2x2
2x4, 2x3
2x8 w/ 2x3 (PER DETAILS) U.N.O.
1. INSTALL APPROVED CORROSION-RESISTANT FLASHING, TO PREVENT
ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER
TO THE BUILDING STRUCTURAL FRAMING COMPONENTS PER R708.3.
SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH
AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE
EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT
FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING
LOCATIONS:
a. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR
WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE
OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE
BARRIER FOR SUBSEQUENT DRAINAGE.
b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY
CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH
PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS.
c. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL
COPINGS AND SILLS.
d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM.
e. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A
WALL OR FLOOR ASSEMBLY OF WOOD-FRAME CONSTRUCTION.
f. AT WALL AND ROOF INTERSECTIONS.
g. AT BUILT-IN GUTTERS.
ELEVATION NOTES:No.DateDescription120160929CITY COMMENTS