HomeMy WebLinkAbout03-21-16 PSE Talbot - Arch Permit SetHOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE CS Cover Sheet TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F 1 1 A1.1 1 A1.1 1 A1.1 1 A1.1 1 2 3 4 1 1 1 8'-0" BUILDING SECTION PARTIAL SECTION WALL SECTION DETAIL BUILDING GRIDS DOOR C.O. FLAG NOTE REVISION NOTES WINDOW C.O. WALL C.O. CEILING OR HEADER HEIGHT INTERIOR ELEVATIONS 1 2400 S PUGET DR., RENTON, WA 98055VICINITY MAP.... SCALE: 1" = 1000' PROJECT DATA PROJECT DESCRIPTION LEGAL DESCRIPTION PUGET SOUND ENERGY - TALBOT CONTROL HOUSE ARCHITECTURAL SYMBOLS INDEX DRAWING SHEET SHEET SHEET NO: NO: NO: (ARCH) TITLE: D-18152 1 CS COVER SHEET ARCHITECTURAL: 2 A1-1 SITE PLAN 3 A1-2 ENL. SITE PLANS / DETAILS 4 A2-1 FLOOR PLAN / REFLECTED CEILING PLAN / ROOF PLAN / SCHEDULES 5 A3-1 BUILDING ELEVATIONS & SECTIONS 6 A4-1 WALL SECTIONS 7 A5-1 INTERIOR ELEVATIONS 8 A6-1 DETAILS 9 A6-2 DETAILS 10 A6-3 TRENCH DETAILS & TRENCH PLANS STRUCTURAL: 11 S1-0 STRUCTURAL NOTES & DRAWING LIST 12 S1-1 STRUCTURAL NOTES, ABBREVIATIONS & SYMBOLS 13 S1-2 SPECIAL INSPECTION SCHEDULE 14 S1-3 SPECIAL INSPECTION SCHEDULE 15 S2-1 FOUNDATION PLAN 16 S2-2 ROOF PLAN 17 S3-1 TYPICAL CONCRETE DETAILS 18 S3-2 CONCRETE DETAILS 19 S3-3 CONCRETE DETAILS 20 S4-1 TYPICAL COLD FORM STEEL DETAILS 21 S4-2 TYPICAL COLD FORM STEEL DETAILS 22 S4-3 COLD FORM STEEL DETAILS MECHANICAL: 23 M1-1 MECHANICAL LEGEND & NOTES 24 M1-2 MECHANICAL SCHEDULES 25 M2-1 MECHANICAL FLOOR PLAN ELECTRICAL: 26 E0-1 ELECTRICAL LEGEND & NOTES 27 E2-1 LIGHTING PLAN 28 E3-1 POWER & SIGNAL PLANS 29 E5-1 ONE-LINE DISTRIBUTION DIAGRAM & MECH EQUIP CONNECTION SCHEDULE 30 E5-2 GROUNDING DIAGRAM, FA RISER 31 E6-2 PANEL SCHEDULES ARCHITECTURAL ABBREVIATIONS PROJECT TEAM 1 THIS PROJECT WILL CONSIST OF A NEW SUBSTATION CONTROL HOUSE CONSTRUCTED FOR PUGET SOUND ENERGY (PSE). THE BUILDING WILL HOUSE CONTROL, METERING, PROTECTION EQUIPMENT AND ACCESSORY SPACES. APPLICABLE CODES: RMC RENTON MUNICIPAL CODE 2012 IBC, WAC 51-52 2009 ANS, ICC/ANSI A117.1-2009 2012 IFC, WAC 51-54 2012 WSEC, WAC 51-11 2012 IMC, WAC 51-52 2008 NEC (NFPA 70), WAC 296-46B-010 2008 NESC C2-2012, WAC 296-46B-010 OWNER: PUGET SOUND ENERGY 10885 NE 4TH, STE #PSE-10S SEATTLE, WA 98009 (425) 456-2535 ROBERT STEWART ARCHITECT: LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 FRANK LAWHEAD STRUCTURAL: KPFF CONSULTING ENGINEERS 1601 5TH AVE, STW #1600 SEATTLE, WA 98101 (206) 622-5822 JIM SWENSON MECHANICAL: HULTZ BHU 1111 S FAWCETT AVE #100 TACOMA, WA 98402 (253) 383-3257 RICK HULTZ ELECTRICAL: HULTZ BHU 1111 S FAWCETT AVE #100 TACOMA, WA 98402 (253) 383-3257 TOM URQUHART SITE ADDRESS: 2400 S PUGET DR. RENTON, WA 98055 PARCEL: A: 2023059066, B:2023059003 PARCEL AREA: A: 13.40 + B: 37.00 = 50.40 ACRES PEDESTRIAN PROTECTION: ≥ 5 FEET AND ONE- HALF THE HT. OF CONST. (IBC 3306.1) NONE REQUIRED ZONING: R-8 -NO OVERLAY DISTRICTS BUILDING AREA: NEW CONTROL HOUSE = 1,449 SF (INSIDE AREA PER EXIST. CONTROL HOUSE = 999 SF IBC 502.1) COMMUNICATION BLDG = 454 SF TOTAL = 2,902 SF SINGLE BUILDING PER IBC 503.1.2 HEIGHT: ±19'-4" PROPOSED – SINGLE STORY (RMC 4-2-110A) 30'-0" ALLOWED CONSTRUCTION TYPE: V-B OCCUPANCY: NEW CONTROL HOUSE: S-2 ALLOWABLE INCIDENTAL USE AREA: 10% BATTERY ROOM = 8.15% , (IBC509.3) 1-HR SEPARATION (IBC TABLE 509) EXISTING CONTROL HOUSE: S-2 COMMUNICATION BUILDING: S-2 OCCUPANCY LOAD: 6 FIRE SPRINKLERS: N/A PLUMBING: N/A PARKING: N/A PARCEL #202305-9003: SW 1/4 OF NE 1/4 LESS PORLY BET PSP & L CO 50 FT ESMT & BPA 200 FT ESMT LESS POR WITHIN PSP & L CO 200 FT SUFFLETON R/W SUBJ TO ESMTS TCO 17-802 PARCEL #202305-9066: POR OF SE 1/4 OF NE 1/4 LY WLY OF C OF S PIPE LN R/W ALSO POR SD SUBD LY NLY OF SLY LN OF BONNEVILLE TRANS LN ESMT R/W & ELY OF C OF S PIPE LN R/W SUBJ TO ESMTS - TCO 17-741 A.C.T. ACOUSTIC CEILING TILE A.F.F. ABOVE FINISH FLOOR APPROX. APPROXIMATE ARCH. ARCHITECTURAL BLDG. BUILDING BLKG. BLOCKING BOTT. BOTTOM C.I. CAST IRON C.J. CONTROL JOINT / CONSTRUCTION JOINT C.O. CALL-OUT C.T. CERAMIC TILE CEIL. CEILINGCL CENTERLINE CLR. CLEAR CONC. CONCRETE CONN. CONNECTION CONST. CONSTRUCTION CONT. CONTINUOUS COL. COLUMN 
 COORD. COORDINATE CSK. COUNTERSINK MANUF. MANUFACTURER / MANUFACTURED MFR. MANUFACTURER MATL. MATERIALMAX. MAXIMUM MECH. MECHANICAL MEZZ. MEZZANINE MIN. MINIMUM MISC. MISCELLANEOUS MTL. METAL D.F. DRINKING FOUNTAIN D.S. DOWNSPOUT DBL. DOUBLE DEPT. DEPARTMENT DIA. DIAMETER DIM. DIMENSION EXIST. EXISTING EXP. EXPOSED EXT. EXTERIOR EQ. EQUAL EQUIP. EQUIPMENT GA. GAUGE GAL. GALLON GALV. GALVANIZED GWB GYPSUM WALLBOARD GYP. GYPSUM H.C. BARRIER-FREE H.M. HOLLOW METALHORIZ. HORIZONTAL HR HOUR HT. HEIGHT I.D. INSIDE DIAMETER IN. INCHES INFO. INFORMATION INSUL. INSULATION INT. INTERIOR LAV. LAVATORY LB. POUND LIN.FT. LINEAR FEET
 LOC. LOCATE N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE NO. NUMBER O.C. ON CENTER O.D. OUTSIDE DIAMETER OCC. OCCUPANCY OCC.’S OCCUPANTS OPP. OPPOSITE P.E.M.B. PRE-ENGINEERED METAL BUILDING PL. PLATEP.L. PROPERTY LINE P-LAM PLASTIC LAMINATE PT. POINT PLUMB. PLUMBING R= RADIUS R.O. ROUGH OPENING RCP REFLECTED CEILING PLAN REF. REFER / REFERENCE REFR. REFRIGERATOR REINF. REINFORCING REQ. REQUIRED / REQUIREMENTS RM. ROOM S.S. STAINLESS STEEL SCWD SOLID CORE WOOD DOOR SECT. SECTION SIM. SIMILAR SL. SEALSPEC. SPECIFICATIONS SQ. SQUARE STD. STANDARD STL. STEEL STRUCT. STRUCTURAL SV SHEET VINYL SYST. SYSTEM T.O. TOP OF... TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE VB VAPOR BARRIER VCT VINYL COMPOSITE TILE VERT. VERTICAL W/ WITH W/O WITHOUT W.C. WATER CLOSET WD WOODWDW. WINDOW WGWB WATER RESISTANT GYPSUM WALLBOARD WT. WEIGHT FT. FEET F.E.C. FIRE EXTINGUISHER CABINET F.H.C. FIRE HOSE CABINET F.D. FLOOR DRAIN F.E. FIRE EXTINGUISHER F.F. FACTORY FINISH F.F.E. FINISH FLOOR ELEVATION F.O. FACE OF…F.O.I.C. FURNISHED BY OWNER INSTALLED BY CONTRACTOR F.O.I.O. FURNISHED BY OWNER INSTALLED BY OWNER F.R.P. FIBER REINFORCED PLASTIC F.V. FIELD VERIFY FDN. FOUNDATION FIN. FINISH FT. FOOT FTG. FOOTING E.J. ELASTOMERIC JOINT / EXPANSION JOINTEA. EACH ELECT. ELECTRICAL ELEV. ELEVATION/ELEVATIONS ENL. ENLARGED SITE HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A1-1 Site Plan TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F PARCEL #: 2023059066 ZONE: R-8 PARCEL #: 2023059003 ZONE: R-8 PARCEL #: 2023059002 ZONE: R-8 PARCEL #: 2023059051 ZONE: R-8 PARCEL #: 2023059073 ZONE: R-8 PARCEL #: 2023059050 ZONE: R-8 B E A C ON WAY S O UT H NEW CONTROL HOUSE B B A A 1 1 2 2 1 N SITE PLAN 1:960 2 HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A1-2 Enl. Site Plans / Details TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F 4" 6" DOOR & THRESHOLD PER SCHEDULE FOUNDATION PER STRUCTURAL SLOPE TO DRAIN PRE-FORMED EXPANSION JOINT FILLER 6" X 6" W.W.F., W1.4 X W1.4 DOWEL SLAB TO FOUNDATION WALL: #4 X 18" @ 18" O.C. (DRILL, EPOXY AND GROUT @ EXIST. CONC., TYP.) STRUCT. FILL PER CIVIL WALKWAY PER 5/A1-1 X 1 A6-2 1 1/2"4"VARIES1'-6" 6" 6"2"5 1/2"6"FOOTING PER STRUCT.MIN.SEE CIVIL FOR SUBSTATION FINISH GRADE GEOTEXTILE FILTER FABRIC COMPACTED SUBGRADE SEE GEOTECH REPORT NATIVE MATERIAL GRANULAR FILL FOR WALLS AND DRAINS CONT. FOOTING DRAIN; WRAP WITH FILTER FABRIC; DRAIN PIPE PERFORATED OR SLOTTED RIGID PVC PIPE LAYED W/ PERFORATIONS OR SLOTS FACING DOWN; TIGHT JOINTED; W/ POSITIVE GRADIENT, 4" MIN. DIA., TYP @ BUILDING PERIMETER DO NOT USE FLEXIBLE CORRUGATED PLASTIC PIPE, TYP. DO NOT TIE BUILDING DOWNSPOUT DRAINS INTO FOOTING LINE, TYP. DRAINAGE TO POSITIVE PERMANENT DISCHARGE SLOPE TO DRAIN; SEE CIVIL FOR ADDITIONAL INFORMATION MIN. MIN. ±206'-0"20'-0"430 4 3 5 438 4 4 2 439435437 443 444 443440433434 435 4414 39 425 430 435 435 440435430 435 438 440 438 439 4384 3 8 438438438 435 430 435 437 444435 432 4 3 2 4 3 0 4 2 5 435 4404354404434384404414424384354 32 EXIST. CONTROL HOUSE BE AC ON WA Y S OU T H FENCE 430PARCEL #: 2023059066 ZONE: R-8 PARCEL #: 2023059003 ZONE: R-8 ROADSITE BASE LINE CONTROL NEW CONTROL HOUSE, TO BE PERPENDICULAR TO SITE BASELINE CONTROL. VERIFY EXACT LOCATION W/ OWNER. TO GRID TO GRIDB B A A 1 1 2 2 NEW CONTROL HOUSE COMM. BLDG 1 BB A 13'-4"5'-6 1/2"38'-8"39'-8"(4) 4" CONDUITS (4) 2" CONDUITS (1) 2" CONDUITFDFDFD FD FD FDFDFD RDRDFDRDFDFDFD SLOPE ROOF & FLOOR DRAINS TO CATCH BASIN; SEE CIVILFOR ADDITIONAL INFO. - TYP. F.F.E. = 438.90' EL. CABLE TRENCHES BY OWNER (FOR REFERENCE ONLY) NOTE: CONDUITS PER E3-1 FOR EXACT LOCATION AND DEPTH FD FDFD 5'-0" x 5'-0" x 6" CONC. PAD CENTERED ON MAN DOOR CABLE TRENCHES BY OWNER (FOR REFERENCE ONLY) RD ROOF OUTLINE RD 5'-0" x 5'-0" x 6" CONC. PAD CENTERED ON MAN DOOR 5'-0" x 5'-0" x 6" CONC. PAD CENTERED ON MAN DOOR AC MDP CABLE VAULT 2 A 1 2 4 A1-2 3 A1-2 NEW TALBOT CONTROL HOUSE 3 CONC. PAD @ BLDG 1 1/2"= 1'-0"4 TYP. FOOTING @ BUILDING EDGE 1" = 1'-0" 1 N ENL. SITE PLAN 1" = 40' 2 N ENL. SITE PLAN 1/8" = 1'-0" 3 GENERAL SHEET NOTES 1. ALL DIMENSIONS ARE TO FACE OF FRAMING. - TYP. U.N.O. 2. EXISTING TOPOGRAPHY SHOWN. SEE CIVIL FOR PROPOSED TOPOGRAPHIC INFORMATION. HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A2-1 Floor Plan / RCP / Roof Plan / Schedules TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F7'-0"3'-0" 1'-0"1'-6"1 AFLOOR LINE 100 A A 101A 1,329 sq ft 108 sq ft 100B 1 1S 1S 2PR 1 1 1 1S 1S B 2 B A CL1 12 A6-1 6'-0"32'-10"18'-0" 18'-0"18'-10"18'-0"18'-0"5'-0"38'-2"39'-8"13'-8"38'-8" 3'-0" 3'-0"4'-6" 2'-0"5'-0" 4 A4-1 3 A4-1 6 7 8 5 A5-1 ROOF OUTLINE ABOVE (DASHED) EYE WASH STATION ( N.I.C.) CONTROL RACKS OVERTURN BRACING TYP 2 2 ROWS, 16 RACKS EACH ROW PRINT TABLE / WORK AREA 4' x 20' (PROVIDED BY PSE) 120V DC BATTERY BATTERY CHARGER CH AC PANEL AC MDP CABLE TRENCH BY OTHERS (FOR REFERENCE ONLY)ALIGNBARD AC UNIT RELAY AC PANELS D.S. D.S. CONTROL OCC. LOAD (1 / 300 SF) = 5 BATTERY OCC. LOAD (1 / 300 SF) = 1 F.E. 1.5'x14' BATTERY RACK W/ (60) VENTED FLOODED LEAD ACID BATTERIES W/ TOTAL OF 30 GAL. MAX. ELECTROLYTE CAPACITY. CONTROL JOINT TYP., SEE S2-1 CABLE TRENCH. COVERS OMITTED FOR CLARITY. SEE A6-3 & D/S3-2 FOR TRENCH DETAILS & 1/A6-2 FOR COVER DETAILS F.E.ALIGNALIGNCABLE TRENCH BY OTHERS (FOR REFERENCE ONLY) SAFETY SWITCH ALIGNALIGN±9'-2" AC MDP CABLE VAULT BATT. 101 7'-6"8'-8"2'-8" 6A3-1 6A3-1 (2) 4" SLEEVES DCPANEL #1 1 A 1 2 101 B 5'-6"2'-8"6'-0"2'-0"11'-4"2'-0"2'-3"9'-0"9'-6"8'-0"8'-0"5 A3-1 5 A3-1 2 3 4 1 A5-1 DCPANEL #3 DCPANEL #2 CONTROL 100 1 B 2 B A 2'-2"1'-2"2'-2"1'-2" 4 A4-1 3 A4-1 METAL SOFFIT CABLE TRAY (30"W X 6"D) METAL SOFFIT EXIT 6" MTL. JOISTS ABOVE. NOTE: SEE MECH. FOR MECHANICAL EQUIPMENT NOT SHOWN HERE. COLD-FORMED STEEL TRUSSES 1-HR RATED CEILING IN BATTERY 102. REFERENCE 1&2/A4-1 FOR COMPOSITION. ALSO REFERENCE GA FILE # FC 4490 FOR ADDITIONAL REQUIREMENTS NOT INCLUDED IN DRAWINGS. TYPICAL RECESSED LIGHT FIXTURE IN MTL. SOFFIT. PROVIDE 12"x12" SHEET MTL. PAN, MIN. 24 GA., W/ INTEGRAL J-TRIM PIECES ALL (4) SIDES TO RECEIVE SOFFIT PANELS. PROVIDE INTERMEDIATE FRAMING AS REQ. TO SUPPORT LIGHT & J-TRIM PIECES. 6 A3-1 6 A3-1 A 1 2 5 A3-1 5 A3-1 8'-6" OPEN TO STRUCT. CONTROL 100 BATT. 102 EXIT EXIT1 B 2 B A CL CL 4 A4-1 3 A4-1 20'-0"1'-2"2'-2"BUILDING OUTLINE TO FACE OF FRAMING (DASHED) STANDING SEAM MTL. ROOF – PRE-FINISHED; SEE SPEC. D.S. D.S. 6 A3-1 6 A3-1 A 1 2 5 A3-1 5 A3-1 4 A6-1 10 A6-1 9 A6-1 10 A6-1 9 A6-1 2'-2"20'-0"1'-2" RIDGE SLOPE4:12SLOPE4:12REMARKSNO.SPACE NAME FLOOR BASE NORTH WESTEAST SOUTH CEILING CONTROL BATTERY CONC/SEALCONC/SEAL EXP./PT.PLYWD/PT.PLYWD/PT.PLYWD/PT. CONC/SEALCONC/SEAL GWBX/PT.GWBX/ PLYWD/PT. GWBX/ PLYWD/PT. GWBX/ PLYWD/PT. GWBX/ PLYWD/PT. GWBX/ PLYWD/PT. WINDOW / LOUVER SCHEDULE REMARKSNO. A ALUM.13/A6-1 1 N FLOOR PLAN 1/8" = 1'-0" 3 NREFLECTED CEILING PLAN 1/8" = 1'-0"2 NROOF PLAN 1/8" = 1'-0" SIZE OPERATION MATERIAL HEAD SILLJAMB FIXED WALL TYPES LEGEND WALL TYPES MODIFIERS RCP LEGEND GWB (GYPSUM WALL BOARD) – PAINT #1; SEE SPEC. EXPOSED SHEATHING –PAINT #2; SEE SPEC. DOOR FRAME NO.SIZE WIDTH X HEIGHT TYPE MAT./FIN.MAT./FIN.THRESH.REMARKS DOOR SCHEDULE FINISH SCHEDULE 101 100 JAMBHEAD HARDWARE DETAILS DETAILS NOTES: (1) HARDWARE MUST MEET THE ICC / ANSI A117.1-2003 STANDARD. (2) KEY CARD ACCESS. (3) DOOR HARDWARE MUST BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. NOTES: (1) MASK OFF ONE FIRE-STAMP PER SHEET BEFORE PAINTING. (2) WALL COMPOSITION SIMILAR TO GA FILE NUMBER WP 1076 CONSTRUCTION. CEILING COMPOSITION SIMILAR TO GA FILE NUMBER FC 4490 CONSTRUCTION. SEE LISTED WALL / CEILING ASSEMBLY FOR ADDITIONAL REQUIREMENTS AND OTHER INFORMATION NOT INCLUDED HERE. 3'-0" X 7'-0"H.M. / PT. 100B 1100A H.M. / PT.1/A6-1 6/A6-1 11/A6-1 101A 3'-0" X 7'-0"H.M. / PT.1 H.M. / PT. 3'-0" X 7'-0"H.M. / PT.1 H.M. / PT. 101B H.M. / PT.1 H.M. / PT.3'-0" X 7'-0" FINISH LEGEND: CONC. CONCRETE EXP. EXPOSED FRAC FIRE-RETARDANT AC OR BETTER PLYWOOD GWB GYPSUM WALL BOARD GWBX FIRE RATED GYPSUM WALL BOARD - 5/8" TYPE-X PLWD PLYWOOD P-LAM PLASTIC LAMINATE PT. PAINT 1/A6-1 6/A6-1 11/A6-1 1/A6-1 6/A6-1 11/A6-1 7/A6-1 7/A6-1 - - 4 WALL / CEILING TO BE 1-HR CONSTRUCTION; NOTE 2 NOTE 2; 45 MIN RATED DOOR 1'-0" X 1-6"3/A6-1 8/A6-1 LOUVER ROOF LEGEND STANDING SEAM MTL ROOFING – PRE-FINISHED; SEE SPEC. DOOR / LOUVER SCHEDULE NOTE 2; NOTE 3; EGRESS NOTE 2; NOTE 3; EGRESS NOTE 2; NOTE 3; EGRESS1 1 3 4 GENERAL SHEET NOTES 1. ALL DIMENSIONS ARE TO FACE OF FRAMING. - TYP. U.N.O. 2. ALL DOORS, DOOR JAMBS, FINISHING GWB, AND FINISHING PLWD ARE TO BE PAINTED. REFER TO SPEC. AND / OR DETAIL SHEETS A6-1 AND A6-2 FOR MORE INFORMATION. 3. REFER TO SPEC FOR PRE-FINISHES ON ALL SIDING, TRIM, ROOFING, SOFFITS, FASCIA, FLASHING, & LOUVERS. S INDICATES SHEAR WALL. SEE STRUCT. FOR LIMITS & ADDITIONAL INFO STRUCT. DRAWINGS GOVERN. P PARTIAL HEIGHT WALL R REFERENCE GA FILE # WP 1076 FOR COMPLETE 1-HOUR RATED WALL COMPOSITION. SEE LISTED WALL ASSEMBLY FOR ADDITIONAL REQUIREMENTS RELATED TO FASTENERS, JOINT LAYOUT, LISTED PROPRIETARY PRODUCTS, AND OTHER INFORMATION NOT INCLUDED HERE. TYPE 1: 6" EXTERIOR WALL - CMU VENEER BASE W/ MTL. SIDING ABOVE - 1 1/2" RIGID INSUL. W. INTEGRAL WATER BARRIER - 1/2" PLWD SHEATHING PER STRUCT. - R-19 BATT INSUL. - 6" MTL. STUDS PER STRUCT. - VAPOR BARRIER - SHEATHING MATERIAL / FINISH PER FINISH SCHEDULE TYPE 2*: 3" 1-HOUR RATED INTERIOR WALL - SHEATHING MATERIAL / FINISH PER FINISH SCHEDULE - 5/8" GWB TYPE X - 3" MTL. STUDS PER STRUCT. - 5/8" GWB TYPE X - SHEATHING MATERIAL / FINISH PER FINISH SCHEDULE HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A3-1 Building Elevations & Sections TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F AA BB 1'-4"1' 1'-4" 1'1'VERTICAL METAL SIDING – PRE-FINISHED; SEE SPEC. CMU VENEER – SEAL; SEE SPEC. CONTROL JOINT (C.J.) – TYP. 124 12 4 PROVIDE BLOCKING & ADDITIONAL FURRING AS NEEDED FOR BARD UNITS PER MANUFACTURER'S REQ.'S. ALL LUMBER TO BE PRESSURE TREATED. - TYP. ALIGN TYP. SECURITY CAMERA BLOCK-OUTS PER 4/A6-2. COORD. POWER W/ OWNER. C.J.C.J.4'-2"5 A3-1 7 A3-1 FINISH GRADE CL 1221 11'-4" CMU VENEER – SEAL; SEE SPEC. VERTICAL METAL SIDING – PRE-FINISHED; SEE SPEC. MECH. VENT, SEE SPEC.'S. METAL RIDGE CAP – PRE-FINISHED; SEE SPEC. PL. HT. 11'-0" ±19'-4" MAX STANDING SEAM METAL ROOFING – PRE-FINISHED; SEE SPEC. (LOUVER HEAD) 10'-2" PROVIDE SIGN ON DOOR TO BATTERY ROOM IN ACCORDANCE W/ IFC 608.7.1FINISH GRADE A.F.F. C.J. D.S. A 6 A3-1 BB AA PL. HT. 11'-0" ±19'-4" MAX VERTICAL MTL. SIDING – PRE-FINISHED; SEE SPEC. CMU VENEER – SEAL; SEE SPEC. COMM. & SECURITY VAULT 12 4 LIGHT FIXTURE OVER DOOR. SEE 2/A6-2. 124 A.F.F. 5 A3-1 7 A3-1 FINISH GRADE 11 22 VERTICAL METAL SIDING – PRE-FINISHED; SEE SPEC. CMU VENEER – SEAL; SEE SPEC. STANDING SEAM MTL ROOFING – PRE-FINISHED; SEE SPEC. METAL RIDGE CAP – PRE-FINISHED; SEE SPEC. TYP. SECURITY CAMERA BLOCK-OUTS PER 4/A6-2. COORD. POWER W/ OWNER. (SEC. BLOCK OUT) 10'-0" TYP. C.J.C.J.D.S. 6 A3-1 FINISH GRADE TYPE 1: INTERIOR STUD WALL 5/8" PLWD*, PAINT 6" METAL STUDS PER STRUCT. 5/8" PLWD*, PAINT TYPE 2: EXTERIOR STUD WALL CMU VENEER BASE W/ METAL SIDING ABOVE 1 1/2" RIGID INSUL. W/INTEGRAL WATER BARRIER 1/2" PLWD SHEATHING PER STRUCT. R-19 BATT INSUL. 8" METAL STUDS PER STRUCT. 5/8" PLWD*, PAINT * AT 1-HOUR RATED WALLS PROVIDE 5/8" TYPE X GWBBETWEEN STUDS AND 5/8" PLWD FINISH LEGEND C.J. CONTROL JOINT A.F.F. ABOVE FINISHED FLOOR PL. HT. PLATE HEIGHT VERTICAL METAL SIDING CMU - SMOOTH FACE CMU - SPLIT FACE A B4 A6-1 CABLE TRAY; SEE STRUCTURAL FOR SEISMIC BRACING CONTROL RACKS 12 4 SAFETY SWITCH BATTERY CHARGER DC PANEL #2 CH AC PANEL AC MDP MDP SKIRT 12 4 1 A4-1 2 A4-1 7'-11"5 A3-1 7 A3-112 CABLE TRAY; SEE STRUCTURAL FOR SEISMIC BRACING PL. HT. 11'-0" DC PANEL #1 A.F.F. BARD AC UNIT 5 A4-1 6 A3-1 4 WEST ELEVATION 1/8" = 1'-0" 1 NORTH ELEVATION 1/8" = 1'-0"2 EAST ELEVATION 1/8" = 1'-0" 3 SOUTH ELEVATION 1/8" = 1'-0" 6 N / S SECTION 1/8" = 1'-0"5 E / W 1/8" = 1'-0" 5 GENERAL SHEET NOTES 1. ALL DIMENSIONS ARE TO FACE OF FRAMING. - TYP. U.N.O. 2. ALL DOORS, DOOR JAMBS, FINISHING GWB, AND FINISHING PLWD ARE TO BE PAINTED. REFER TO SPEC. AND / OR DETAIL SHEETS A6-1 AND A6-2 FOR MORE INFORMATION. 3. REFER TO SPEC FOR PRE-FINISHES ON ALL SIDING, TRIM, ROOFING, SOFFITS, FASCIA, FLASHING, & LOUVERS. HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A4-1 Wall Sections TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F 1 3 A6-2 1 A6-2 9 A6-1 3'-8"FINISH GRADE R-10 SLAB INSUL. - SLAB PER STRUCT; - VAPOR BARRIER; - 4" COURSE, FREE DRAINING GRAVEL; - STRUCT FILL PER GEOTECH REPORT FOOTING PER STRUCT. - METAL SIDING; •PRE-FINISHED; SEE SPEC. - 1 1/2" R-10 RIGID INSUL. W/ INTEGRAL WATER BARRIER; - 1/2" PLWD SHEATHING PER STRUCT; - R-19 BATT INSUL.; - 6" MTL. STUDS PER STRUCT; - VAPOR BARRIER; - 5/8" PLWD; •PAINT; SEE SPEC. - CMU VENEER; •SEAL; SEE SPEC. - 1 1/2" AIRSPACE; - 1 1/2" RIGID INSUL. W/INTEGRAL WATER BARRIER; - 1/2" PLWD SHEATHING PER STRUCT; - R-19 BATT INSUL; - 6" MTL STUDS PER STRUCT; - VAPOR BARRIER; - 5/8" PLWD; •PAINT; SEE SPEC. - METAL ROOFING; •PRE-FINISHED; SEE SPEC. - SELF-ADH. ICE & WATER SHIELD; - 6" R-30 RIGID INSUL.; - 5/8" PLWD SHEATHING PER STRUCT; •PAINT; SEE SPEC. - MTL. TRUSSES PER STRUCT - PAINT 11'-0" PL. HT. COMPACTED SUBGRADE A.F.F. 10'-0" TOP OF BARD UNIT A 10 A6-1 3 A6-2 5 A6-1 1 A6-2 6"3'-8"4"1'-6" 11'-0" PL. HT. MIN CONT. FOOTING DRAIN; WRAP WITH FILTER FABRIC; DRAIN PIPE PERFORATED OR SLOTTED RIGID PVC PIPE LAYED W/ PERFORATIONS OR SLOTS FACING DOWN; TIGHT JOINTED; W/ POSITIVE GRADIENT, 4" MIN. DIA., TYP @ BUILDING PERIMETER, DO NOT USE FLEXIBLE CORRUGATED PLASTIC PIPE, DRAINAGE TO POSITIVE PERMANENT DISCHARGE GRANULAR FILL FOR WALLS AND DRAINS GEOTEXTILE FILTER FABRIC R-10 SLAB INSUL. FINISH GRADE - METAL SIDING; •PRE-FINISHED; SEE SPEC. - 1 1/2" R-10 RIGID INSUL. W/ INTEGRAL WATER BARRIER; - 1/2" PLWD SHEATHING PER STRUCT; - R-19 BATT INSUL.; - 6" MTL. STUDS PER STRUCT; - VAPOR BARRIER; - 5/8" TYPE X GWB; - 5/8" PLWD •PAINT; SEE SPEC. MIN MIN- SLAB PER STRUCT; - VAPOR BARRIER; - 4" COURSE, FREE DRAINING GRAVEL; - STRUCT FILL PER GEOTECH REPORT COMPACTED SUBGRADE FOOTING PER STRUCT. ROOF PROFILE: - METAL ROOFING; •PRE-FINISHED; SEE SPEC. - SELF-ADH. ICE & WATER SHIELD; - 6" R-30 RIGID INSUL.; - 5/8" PLWD SHEATHING PER STRUCT; - MTL. TRUSSES PER STRUCT •PAINT; 1-HR RATED CEILING: (GA. FILE NO FC4490) - 1/2" PLYWOOD; - 6" MTL. JOISTS; - (2) LAYERS OF 5/8" TYPE X GWB •PAINT; SEE SPEC. A.F.F. - SLAB PER STRUCT; - VAPOR BARRIER; - 4" COURSE, FREE DRAINING GRAVEL; - STRUCT FILL PER GEOTECH REPORT 1-HR RATED WALL: (GA. FILE NO. WP1076) - 1/2" PLWD; •PAINT; SEE SPEC. - 5/8" TYPE X GWB; - 3" MTL. STUDS PER STRUCT; - R-19 BATT INSUL.; - 5/8" TYPE X GWB; - 5/8" PLWD •PAINT; SEE SPEC. ROOF PROFILE: - METAL ROOFING; •PRE-FINISHED; SEE SPEC. - SELF-ADH. ICE & WATER SHIELD; - 6" R-30 RIGID INSUL.; - 5/8" PLWD SHEATHING PER STRUCT; - MTL. TRUSSES PER STRUCT. •PAINT; 1-HR RATED CEILING: (GA. FILE NO FC4490) - 1/2" PLYWOOD; - 6" MTL. JOISTS; - (2) LAYERS OF 5/8" TYPE X GWB •PAINT; SEE SPEC. 8'-6" BATTERY ROOM CEILING A.F.F. 9'-1 3/4" TOP OF FINISH MATERIAL 2 5 A6-3 2"2"- METAL ROOFING; •PRE-FINISHED; SEE SPEC. - SELF-ADH. ICE & WATER SHIELD; - 6" R-30 RIGID INSUL.; - 5/8" PLWD SHEATHING PER STRUCT; •PAINT; SEE SPEC. - MTL. TRUSSES PER STRUCT - PAINT - METAL SIDING; •PRE-FINISHED; SEE SPEC. - 1 1/2" R-10 RIGID INSUL. W/ INTEGRAL WATER BARRIER; - 1/2" PLWD SHEATHING PER STRUCT; - R-19 BATT INSUL.; - 6" MTL. STUDS PER STRUCT; - VAPOR BARRIER; - 5/8" PLWD •PAINT; SEE SPEC. COMPACTED SUBGRADE FOOTING PER STRUCT. - SLAB PER STRUCT; - VAPOR BARRIER; - 4" COURSE, FREE DRAINING GRAVEL; - STRUCT FILL PER GEOTECH REPORT FINISH GRADE EXTERIOR PRE-MANUFACTURED CABLE TRENCH (FOR REFERENCE ONLY) INTERIOR CABLE TRENCH 2 1 A6-1 SLAB ON GRADE R-10 SLAB INSUL. - SLAB PER STRUCT; - VAPOR BARRIER; - 4" COURSE, FREE DRAINING GRAVEL; - STRUCT FILL PER GEOTECH REPORT COMPACTED SUBGRADE - METAL SIDING; •PRE-FINISHED; SEE SPEC. - 1 1/2" R-10 RIGID INSUL. W/ INTEGRAL WATER BARRIER; - 1/2" PLWD SHEATHING PER STRUCT; - R-19 BATT INSUL.; - 6" MTL. STUDS PER STRUCT; - VAPOR BARRIER; - 5/8" PLWD •PAINT; SEE SPEC. - METAL ROOFING; •PRE-FINISHED; SEE SPEC. - SELF-ADH. ICE & WATER SHIELD; - 6" R-30 RIGID INSUL.; - 5/8" SHEATHING PER STRUCT; •PAINT; SEE SPEC. - MTL. TRUSSES PER STRUCT - PAINT FOOTING PER STRUCT. 3 WALL SECTION 1/2" = 1'-0"1 WALL SECTION 1/2" = 1'-0"2 WALL SECTION 1/2" = 1'-0"5 WALL SECTION 1/2" = 1'-0"4 WALL SECTION 1/2" = 1'-0" 6 GENERAL SHEET NOTES 1. ALL DIMENSIONS ARE TO FACE OF FRAMING. - TYP. U.N.O. 2. ALL DOORS, DOOR JAMBS, FINISHING GWB, AND FINISHING PLWD ARE TO BE PAINTED. REFER TO SPEC. AND / OR DETAIL SHEETS A6-1 AND A6-2 FOR MORE INFORMATION. 3. REFER TO SPEC FOR PRE-FINISHES ON ALL SIDING, TRIM, ROOFING, SOFFITS, FASCIA, FLASHING, & LOUVERS. HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A5-1 Interior Elevations TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F PROVIDE SIGN BY DOOR TO BATTERY ROOM IN ACCORDANCE W/ IFC 608.7.1 COLD-FORMED STEEL TRUSSES 5/8" A/C PLYWOOD OR BETTER – PAINT; SEE SPEC. DC PANEL #1 DC PANEL #2 DC PANEL #3 7'-11"5/8" A/C PLYWOOD OR BETTER – PAINT; SEE SPEC. CONC. CURB - TYP. F.E. COLD-FORMED STEEL TRUSSES TO BE PAINTED - TYP. CABLE TRAY PER ELEC.; SEISMIC BRACING PER STRUCT. 5/8" A/C PLYWOOD OR BETTER – PAINT; SEE SPEC. AC MDP RELAY AC PANEL CONTROL RACKS MTL SKIRT COLD-FORMED STEEL TRUSSES CABLE TRAY PER ELEC.; SEISMIC BRACING PER STRUCT. CONC. CURB - TYP. 5/8" A/C PLYWOOD OR BETTER – PAINT; SEE SPEC. CONC. CURB -TYP. COLD-FORMED STEEL TRUSSES BATTERY STG RACKS F.O.I.O. CONC. CURB - TYP.CONC. CURB TYP. 1 100 N CONTROL 1/4" = 1'-0" 4 100 W CONTROL 1/4" = 1'-0" 2 100 E CONTROL 1/4" = 1'-0" 3 100 S CONTROL 1/4" = 1'-0" 5 101 N BATT.1/4" = 1'-0"8 101 W BATT.1/4" = 1'-0"6 101 E BATT.1/4" = 1'-0"7 101 S BATT.1/4" = 1'-0" 5/8" A/C PLYWOOD OR BETTER – PAINT; SEE SPEC. NOTE: PROVIDE FIRE BARRIER CAULK @ FIRE WALL PENETRATIONS. 7 GENERAL SHEET NOTES 1. ALL DIMENSIONS ARE TO FACE OF FRAMING. - TYP. U.N.O. 2. ALL DOORS, DOOR JAMBS, FINISHING GWB, AND FINISHING PLWD ARE TO BE PAINTED. REFER TO SPEC. AND / OR DETAIL SHEETS A6-1 AND A6-2 FOR MORE INFORMATION. HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A6-1 Details TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F STUDS / HEADER PER STRUCT. HOLLOW MTL. FRAME, – PAINT; SEE SPEC. CONT. CAULK, TYP. 5/8" PLWD – PAINT; SEE SPEC. 5/8" GWB TYPE X2"4" HOLLOW MTL. DOOR HEAD – PAINT; SEE SPEC. CAULK MTL. SIDING – PRE-FINISHED; SEE SPEC. METAL FLASHING W/ HEM, SLOPE TO DRAIN – PRE-FINISHED; SEE SPEC. WEATHERMATE™ FLASHING, - TYP. @ EXT. CONDITION WEATHERMATE™ FLASHING 1 1/2" RIGID INSUL W/ INTEGRAL WATER RESISTIVE BARRIER 1/2"1/4"DOOR AS SCHEDULED – PAINT; SEE SPEC. CONC. SLAB FLOOR COVERING AS SCHEDULED EDGE TRIM/ THRESHOLD NOTE: HEIGHT DIFFERENCE BETWEEN CONC. SLABS NOT TO EXCEED 1/4", TYP. NOTE: SLOPE NOT TO EXCEED 1:2 EXPANSION MATERIAL HOLLOW MTL. FRAME, – PAINT; SEE SPEC. CONT. CAULK CMU VENEER CUT FROM FULL 8x16 BLOCK, NOTE: @ SPLIT-FACE - TWO SIDES SPLIT, TYP. – SEAL; SEE SPEC. WEATHERMATE FLASHING, - TYP. @ EXT. CONDITION CONT. BACKER ROD & MATCHING COLOR SANDED SEALANT 1/2" PLWD SHEATHING PER STRUCT. 1 1/2" RIGID INSUL W/ INTEGRAL WATER RESISTIVE BARRIER GROUND FACE @ H.M. JAMBS METAL SIDING – PRE-FINISHED; SEE SPEC. LOUVER WITH SCREEN; – PRE-FINISHED; SEE SPEC. L 1/8" X 1.5" X 1.5" CONT., – PAINT, TYP.; SEE SPEC. CONTINUOUS SEALANT TRIM W/ DRIP EDGE – PRE-FINISHED; SEE SPEC. CONTINUOUS SEALANT R-19 BATT INSULATION LT. GA. MTL. FRAMING 1/2" PLWD SHEATHING PER STRUCT. 1 1/2" RIGID INSUL W/ INTEGRAL WATER RESISTIVE BARRIER WEATHERMATE FLASHING 5/8" GWB TYPE X 5/8" PLWD – PAINT; SEE SPEC. METAL SIDING – PRE-FINISHED; SEE SPEC. CONTINUOUS SEALANT J TRIM – PRE-FINISHED; SEE SPEC. L 1/8" X 1.5" X 1.5" CONT. – PAINT; SEE SPEC. LOUVER WITH SCREEN – PRE-FINISHED; SEE SPEC. 2 "± 7 1 / 2 "6 3 / 4 "3"4" METAL SOFFIT PANELS – PRE-FINISHED; SEE SPEC. STANDING SEAM MTL. ROOF – PRE-FINISHED; SEE SPEC. 6" RIGID INSULATION 5/8" PLWD SHEATHING PER STRUCT. LT. GA. FRAMING/BLKG METAL FASCIA, W/ DRIP – PRE-FINISHED; SEE SPEC. J-TRIM – PRE-FINISHED; SEE SPEC. MODIFY PANEL TO HOOK AROUND CLEAT ALLOW MIN. 1" EXP. & CONTR. RETURN END FLAP INTO SEAM AND RIVET. CAULK END OF SEAM, TYPICAL CONT. CLEAT APPLY CONT. GUNNABLE GRADE CAULK @ 12" O.C. NOT MORE THAN 2" UPHILL FROM EAVE CLIP CLIP ICE & WATER SHIELD MATCH EAVE FACIA, F.V. – PRE-FINISHED; SEE SPEC. METAL FASCIA, W/ DRIP – PRE-FINISHED; SEE SPEC. VERIFY W/ TRUSS CHORD DEPTH 2" METAL SOFFIT PANELS – PRE-FINISHED; SEE SPEC. STANDING SEAM MTL. ROOF – PRE-FINISHED; SEE SPEC. 6" RIGID INSULATION 5/8" PLWD SHEATHING PER STRUCT. LT. GA. FRAMING/BLKG METAL FASCIA, W/ DRIP J-TRIM – PRE-FINISHED; SEE SPEC. CLIP J TRIM W. 2" REVEAL, TYP. – PRE-FINISHED; SEE SPEC. METAL SIDING – PRE-FINISHED; SEE SPEC. MATCH EAVE FACIA, F.V. BACKER ROD & SEALANT MATCH STANDING SEAM FOAM CLOSURE, APPLIED W/ ADHESIVE, TYP. OUTLOOKER PER STRUCT METAL FASCIA, W/ DRIP MATCH EAVE FACIA, F.V. NOTE: RAKE TO MATCH EAVE DEPTH ±7 3/4"6 3/4"2 1/4"STANDING SEAM MTL. ROOF – PRE-FINISHED; SEE SPEC. MTL. SIDING – PRE-FINISHED; SEE SPEC. J-TRIM, W/ 2" REVEAL, TYP. – PRE-FINISHED; SEE SPEC. SOFFIT PANEL – PRE-FINISHED; SEE SPEC. 6" RIGID INSULATION BACKER ROD & SEALANT, - TYP. 5/8" PLWD SHEATHING BLKG AS NEEDED 1 1/2" RIGID INSUL. SEE STRUCTURAL FOR FRAMING RIDGE FLASHING – PRE-FINISHED; SEE SPEC. GUNNABLE GRADE CAULK TYP. 2 FASTENERS PER PANEL MIN. METAL ROOF PANEL – PRE-FINISHED; SEE SPEC. RIVET FLASHING TO Z-CLOSURE @ 12" O.C. MAX. Z-CLOSURE; CUT TO FIT BETWEEN STANDING SEAMS; APPLY GUNNABLE GRADE CAULK BETWEEN PANEL AND Z-CLOSURE CLIP BLOCKING -WOOD OR MTL ICE & WATER SHIELD 6" RIGID INSUL 5/8" PLWD SHEATHING PER STRUCT.1/2"STANDING SEAM MTL. ROOFING – PRE-FINISHED; SEE SPEC. MTL. STUDS PER STRUCT. 1/2" DEFLECTION GAP. SEAL W/ FIRE CAULK 5/8" PLWD SHEATHING PER STRUCT. 6" RIGID INSUL. DEFLECTION TRACK FINISHES DIFFER DEPENDING ON WALL TYPE. SEE 1/A2-1 AND WALL TYPE LEGEND ON A2-1 2"2"METAL SIDING – PRE-FINISHED; SEE SPEC. J-TRIM – PRE-FINISHED; SEE SPEC. CORNER TRIM – PRE-FINISHED; SEE SPEC. 1 1/2" RIGID INSUL W/ INTEGRAL WATER RESISTIVE BARRIER 1/2" PLWD SHEATHING PER STRUCT. WEATHERMATE™ FLASHING L 1/8" X 1.5" X 1.5" CONT. – PAINT; SEE SPEC. LOUVER W/SCREEN CONT. SEALANT CONTINUOUS BACK- ER ROD &SEALANT LT. GA. MTL. FRAMING 1 1/2" RIGID INSUL W/ INTEGRAL WATER RESISTIVE BARRIER 1/2" PLWD SHEATHING PER STRUCT. WEATHERMATE™ FLASHING 5/8" GWB TYPE X 5/8" PLWD – PAINT; SEE SPEC. 7 INT. DOOR HEAD 3" = 1'-0" 1 EXT. DOOR HEAD 3" = 1'-0" 11 EXT. DOOR THRESHOLD 6" = 1'-0" 6 EXT. DOOR JAMB @ CMU 3" = 1'-0" 3 LOUVER HEAD 3" = 1'-0" 8 LOUVER JAMB 3" = 1'-0"10 FASCIA @ EAVE 1 1/2"= 1'-0"9 FASCIA/SOFFIT @ RAKE 1 1/2"= 1'-0" 5 WALL @ EAVE SOFFIT 1 1/2"= 1'-0"4 METAL ROOF @ RIDGE 3" = 1'-0"2 INT. WALL @ ROOF TYP.1 1/2"= 1'-0" 12 MTL SIDING @ CORNER 3" = 1'-0"13 LOUVER SILL 3" = 1'-0" 8 GENERAL SHEET NOTES 1. ALL DIMENSIONS ARE TO FACE OF FRAMING. - TYP. U.N.O. 2. ALL DOORS, DOOR JAMBS, FINISHING GWB, AND FINISHING PLWD ARE TO BE PAINTED. REFER TO SPEC. AND / OR DETAIL SHEETS A6-1 AND A6-2 FOR MORE INFORMATION. 3. REFER TO SPEC FOR PRE-FINISHES ON ALL SIDING, TRIM, ROOFING, SOFFITS, FASCIA, FLASHING, & LOUVERS. HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A6-2 Details TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F 1 1/2" MTL. SIDING – PRE-FINISHED; SEE SPEC. 4" CMU VENEER – SEAL; SEE SPEC. 1/2" PLWD SHEATHING PER STRUCT. 3'-8" A.F.F. METAL FLASHING W/ HEM, SLOPE TO DRAIN – PRE-FINISHED; SEE SPEC. 1 1/2" RIGID INSUL. CONTINUOUS BACKER ROD &SEALANT SLOPED CMU SILL CAP – SEAL; SEE SPEC. 1" 1'-0" 1"1'-0"1'-0"1"1/2"1'-2"1"1/2"1"1/2" 1'-0" 24GA. SHEET MTL., EXTEND UNDER TRIM 1/2" MIN., MATCH TRIM COLOR CENTER DEVICE IN RECESS, IF DEVICE IS LARGER THAN RECESS, VERIFY W/ ARCHITECT. PROVIDE PENETRATION FLASHING PER FLASHING MANUF. RECOMMENDATION @ J-TRIM, TYP. (NOT SHOWN FOR CLARITY) J TRIM W/ 1/2" MODIFIED LEADING EDGE, EXTEND 1" MIN. @ WALL AND FOLD ENDS DOWN 1" MIN. TRIM & BACK PLATE (EXPLODED): TRIM & BACK PLATE (ASSEMBLED): COVER TRIM: TRIM ASSEMBLED: OVERLAP VERT. J-TRIM CONT. SEALANT BETWEEN TRIM AND WALL, TYP. HEM EDGES, TYP. CUT AND BEND TRIM INWARDS FULL DEPTH OF RECESS AFTER HEMMING EDGE, TYP. HEM EDGES, TYP. RIVET COVER TO J-TRIM, COLOR MATCH TO TRIM, TYP. NOTE: METAL SIDING NOT SHOWN FOR CLARITY, PROVIDE FOAM CLOSURES, MAKE HOLE IN SIDING SMALL AS POSSIBLE INSTALL FRONT TRIM PIECE AFTER SIDING INSTAL. ALIGN ALIGN NOTE: TYP. RECESS IS 12"X12", IF DEVICE REQUIRES A LARGER AREA VERIFY W/ ARCHITECT FOR NEW SIZE. FABRICATE COVER TRIM FROM ONE PIECE OF FLAT STOCK CAULK INSIDE CORNERS, MATCH TRIM COLOR, TYP.U.N.O.U.N.O. U.N.O.U.N.O.U.N.O. X 1 1/2" FOOTING, REINF. & ANCHORS PER STRUCT. 2" RIGID INSUL. R-10 TYP. THRU WALL FLASHING, TYP. 3/16 " WEEP HOLES @ 24" O.C., TYP. AIR SPACE, TYP. WEATHERMATE™ FLASHING 1/2" FELT STRIP 1 1/2" RIGID INSUL W/ INTEGRAL WATER RESISTIVE BARRIER 1/2" PLWD SHEATHING PER STRUCT. R-19 BATT INSUL. FINISH GRADE BATTERY ROOM EXTERIOR FACE 7 1/2"6" 1'-2"7 1/4"METAL SHROUD TO COVER FRAMED BUMP- OUT, WELDED SEAMS, COLOR TO MATCH SIDING MTL. SIDING – PRE-FINISHED; SEE SPEC. LIGHT FIXTURE PER ELECT. 9'-0" A.F.F. CONT. CAULK, TYP. METAL FLASHING ASSEMBLY W/ HEM, SEE TYP. MTL TRIM DETAIL – PRE-FINISHED; SEE SPEC. MTL SHROUD, WELD SEAMS, F.V. DEPTH – PRE-FINISHED; SEE SPEC. WEATHERMATE™ FLASHING, WRAP ENTIRE BUMP-OUT 1 1/2" RIGID INSUL W/ INTEGRAL WATER RESISTIVE BARRIER F.V.F.V.LIGHT FIXTURE PER ELECT. FRONT ELEVATION 3 CMU TO MTL SIDING 1 1/2"= 1'-0"4 TYP. MTL TRIM @ WALL 1 1/2"= 1'-0" 1 WALL BASE @ CMU 1 1/2"= 1'-0"2 SUPPORT @ LIGHT 1 1/2"= 1'-0" 9 GENERAL SHEET NOTES 1. ALL DIMENSIONS ARE TO FACE OF FRAMING. - TYP. U.N.O. 2. ALL DOORS, DOOR JAMBS, FINISHING GWB, AND FINISHING PLWD ARE TO BE PAINTED. REFER TO SPEC. AND / OR DETAIL SHEETS A6-1 AND A6-2 FOR MORE INFORMATION. 3. REFER TO SPEC FOR PRE-FINISHES ON ALL SIDING, TRIM, ROOFING, SOFFITS, FASCIA, FLASHING, & LOUVERS. HOUSE 3 21 16 0 PERMIT SET ... CLR 111022315 SCALE:FILE NO: SHEET: REV NODRAWING NO 12345678 12345678 A B C D E A B C D E CADD NO: CLASS: DATE (M/D/Y)SUBSTATION ENGINEERING DEPARTMENT $FILE$$DATE$$USER$CODE: ENGINEER REVIEWED REVISION DESCRIPTION: CAD APPROVED WO NUMBER: OF: D-18740 CONTROL HOUSE A6-3 Trench Details & Trench Plans TALBOT SUBSTATION 31 VARIES LAWHEAD ARCHITECTS P.S. 12342 NORTHUP WAY BELLEVUE, WA 98005 (425) 556-1220 -P(425) 556-1228 -F1 3/4"2"1'-1 1/2" 6"7 1/2" EXT. CABLE TRENCH (OLDCASTLE, F.O.I.O.) EXPOSED FACE OF FOUNDATION WALL 2 GRIDLINE TO EXT. FACE OF CURB / EXT. FACE OF STUD. - TYP. CMU AIR SPACE MTL. STUDS CONTROL HOUSE F.F.E. @ 438.90' SEE CIVIL FOR SUBSTATION FINISH GRADE INT. CABLE TRENCH INSUL / SHEATHING VARIES, SEE STRUCT.8 1/2"1'-0"10"1'-1 3/4"1'-4 1/4"2"6"1'-1 1/2"3 1/2" 7 1/2"5'-6 1/2"13'-4" 2'-0"8 1/2"8 1/2"2'-0" 5 A6-3 EXT. CABLE TRENCH (OLDCASTLE, F.O.I.O.) CONTROL HOUSE F.F.E. @ 438.90' SEE CIVIL FOR SUBSTATION FINISH GRADE B CONCRETE LEDGER FOR CABLE TRENCH EXTERIOR CABLE TRENCHES (OLDCASTLE) REFER TO B/S3-2 FOR MORE INFO WINDOW OPENING IN FOUNDATION 5'-6 1/2"13'-4" 6'-0"13'-4" 2'-0"2'-0" FOOTING BELOWB 2 INT. CABLE TRENCHES EXT. CABLE TRENCHES (OLDCASTLE) REFER TO B/S3-2 FOR MORE INFO REFER TO D/S3-2 FOR MORE INFO CURB / STUD WALL 7 1/2" 2'-0"1'-8 1/2"2'-0" B INT. CABLE TRENCHES 1'-8 1/2"REFER TO D/S3-2 FOR MORE INFO 5'-10 1/2"13'-4"2'-0" (15)1/4"x2'-0"x2'-3" GALV. COVER PL. SEE D/S3-2 & SPEC. FOR MORE INFO. B 1 A 2 TO TRENCH COVER TO TRENCH COVER (2)1/4"x1'-6 3/4"x3'-0" GALV. COVER PL. SEE J/S3-3 & SPEC. FOR MORE INFO. (1)1/4"x2'-2"x1'-9 1/2" GALV. COVER PL. SEE K/S3-3 & SPEC. FOR MORE INFO. BATT. 101 CONTROL 100 5 CABLE TRENCH SECTION 1" = 1'-0"4 EXTERIOR CABLE TRENCH SECTION 1" = 1'-0" 3 CABLE TRENCH PLAN 1" = 1'-0" 2 INTERIOR CABLE TRENCH SECTION 1" = 1'-0" 1 TRENCH COVER PLAN 1/8" = 1'-0" 10