Loading...
HomeMy WebLinkAboutSNP1_90pct_Dwgs_12.15.2016_22x3498102-3513 BUSH, ROED & HITCHINGS, INC. 2009 MINOR AVE. EAST SEATTLE, Washington LAND SURVEYORS & CIVIL ENGINEERS FAX# (206) 323-7135 (206) 323-4144 1-800-935-0508 NW 1/4, SECTION 9, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. TOPOGRAPHIC SURVEY CITY OF RENTON SUNSET PARK RENTON KING COUNTY WASHINGTON6/02/16 \\Brh02\cad\C3D\2016\2016077\SURVEYING\DWG\XS-SUR-00.dwg, 6/2/2016 3:12:41 PM, DWG To PDF.pc3, 1:1 98102-3513 BUSH, ROED & HITCHINGS, INC. 2009 MINOR AVE. EAST SEATTLE, Washington LAND SURVEYORS & CIVIL ENGINEERS FAX# (206) 323-7135 (206) 323-4144 1-800-935-0508 NW 1/4, SECTION 9, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. TOPOGRAPHIC SURVEY CITY OF RENTON SUNSET PARK RENTON KING COUNTY WASHINGTON6/02/16 \\Brh02\cad\C3D\2016\2016077\SURVEYING\DWG\XS-SUR-00.dwg, 6/2/2016 3:12:59 PM, DWG To PDF.pc3, 1:1 98102-3513 BUSH, ROED & HITCHINGS, INC. 2009 MINOR AVE. EAST SEATTLE, Washington LAND SURVEYORS & CIVIL ENGINEERS FAX# (206) 323-7135 (206) 323-4144 1-800-935-0508 NW 1/4, SECTION 9, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. TOPOGRAPHIC SURVEY CITY OF RENTON SUNSET PARK RENTON KING COUNTY WASHINGTON6/02/16 \\Brh02\cad\C3D\2016\2016077\SURVEYING\DWG\XS-SUR-00.dwg, 6/2/2016 3:13:18 PM, DWG To PDF.pc3, 1:1 98102-3513 BUSH, ROED & HITCHINGS, INC. 2009 MINOR AVE. EAST SEATTLE, Washington LAND SURVEYORS & CIVIL ENGINEERS FAX# (206) 323-7135 (206) 323-4144 1-800-935-0508 NW 1/4, SECTION 9, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M. TOPOGRAPHIC SURVEY CITY OF RENTON SUNSET PARK RENTON KING COUNTY WASHINGTON6/02/16 \\Brh02\cad\C3D\2016\2016077\SURVEYING\DWG\XS-SUR-00.dwg, 6/2/2016 3:13:38 PM, DWG To PDF.pc3, 1:1 SURGE ARRESTORSLIGHTNING ARRESTORSMICROPROCESSOR CONTROLLED MONITORPROTECTIVE FUNCTIONSREFER TO SPECIFICATIONS FOR METERING VALUES ANDMMMETERPOLE-MOUNTED TRANSFORMERTRANSFORMERCURRENT TRANSFORMERPOTENTIAL TRANSFORMERNEUTRAL GROUNDING RESISTORTWYEDELTAASkVAR-KILOVAR METER; kWH-KILOWATT HOUR METER;SS-SYNCHRONIZING SWITCH;AS-AMMETER SWITCH; VS-VOLTMETER SWITCH;kWH/D-KILOWATT HOUR DEMAND METERSV-SUPERVISORY (LOCAL-REMOTE) SWITCHAM-AMMETER; VM-VOLTMETER; FM-FREQUENCY METER;INSTRUMENT SWITCHINDICATING INSTRUMENTDRAWOUT AC TYPE POWER CIRCUIT BREAKERMEDIUM VOLTAGE CABLE TERMINATORSEPARABLE CONNECTORSYMBOLDESCRIPTIONSYMBOLS LEGEND - POWERSYMBOLDESCRIPTIONSYMBOLS LEGEND - LIGHTINGM- -XXXXS2STRIP FLUORESCENTWALL MOUNTED FLUORESCENT LUMINAIREWALL MOUNTED LUMINAIREDOWNLIGHT STAGGERED-STRIP FLUORESCENTWALL MOUNTED DIRECTIONAL LUMINAIRENUMBER OF LUMINAIRES AS SHOWNTRACK LIGHT - LENGTH AS INDICATED ON PLANSWALL WASH LUMINAIRECIRCUIT OR WITH BATTERY BACKUP BALLASTSHADING INDICATES LUMINAIRE ON EMERGENCY2x4 FLUORESCENT1x4 FLUORESCENT2x2 FLUORESCENTNLTCPPXXXXLIGHT FIXTURE IDENTIFIER - REFER TO LIGHTING FIXTURE SCHEDULEUNDER-CABINET FLUORESCENT LUMINAIRERESISTORMTINDICATING LIGHT - TYPE AS NOTEDA-AMBER; B-BLUE; G-GREEN; R-RED; W-WHITEMOTOR-OPERATED VALVEBATTERY65°THERMOSTATNORMALLY CLOSED CONTACTNORMALLY OPEN CONTACTGSTGTERMINAL BLOCKMOV SURGE PROTECTIONMOTOR-OPERATED CIRCUIT BREAKERCIRCUIT BREAKER WITH GROUND FAULT PROTECTIONSWITCH WITH EXTERNAL GROUND FAULT RELAY AND CTBREAKER WITH EXTERNAL GROUND FAULT RELAY AND CTST - INDICATES SHUNT TRIPSVCBMOTOR THERMAL OVERLOADS - (3) UNLESS OTHERWISE NOTEDSOLENOID VALVECIRCUIT BREAKERFUSESYMBOLDESCRIPTIONSYMBOLS LEGEND - POWERBGROUND WELLGROUND RODGROUND CONNECTIONSYMBOLDESCRIPTIONSYMBOLS LEGEND - GROUNDINGAIR TERMINALALARM PUSHBUTTON. P - INDICATES WITH PILOT LIGHTCARD READER. WP INDICATES WEATHERPROOFMOTION DETECTOR - INFRARED TYPE UNLESS OTHERWISE NOTEDELECTRIC DOOR STRIKECCTV CAMERA - FIXED TYPE. WP INDICATES WEATHERPROOFCCTV CAMERA - PAN/TILT/ZOOM TYPE. WP INDICATES WEATHERPROOFSYMBOLDESCRIPTIONSYMBOLS LEGEND - SECURITYDOOR/WINDOW CONTACTKEYPAD. WP INDICATES WEATHERPROOFREQUEST TO EXIT PUSHBUTTONALARM HORN WITH CHIMEALARM BUZZERALARM BELLSTGMMDESWPWPPAAABREAK GLASS SENSORBGREXCKWPEQUIPMENT EMERGENCY SHUTDOWN SWITCHMOTOR-RATED SWITCH - SIZE OL PER MOTOR REQUIREMENTSMOTOR CONNECTION EQUIPMENT CONNECTIONGENERATORCOMBINATION STARTERHP RATED, 3-POLE, NEMA SIZE 1 MINIMUM, UNLESS NOTEDBY EQUIPMENT MANUFACTURER OR AS NOTED3-POLE UNLESS NOTED OTHERWISE DISCONNECT SWITCHFUSED DISCONNECT SWITCHOR AS NOTEDPROTECTION AS REQUIRED BY EQUIPMENT MANUFACTURER 3-POLE UNLESS NOTED OTHERWISE - OVERCURRENT OTHERWISE - OVERCURRENT PROTECTION AS REQUIRED MSTARTER 3-POLE, NEMA SIZE 1 MINIMUM UNLESS NOTED OTHERWISE2-CIRCUIT PUSHBUTTON2-POSITION SELECTOR SWITCHPUSHBUTTON SWITCH MOMENTARY CONTACTON-OFF SELECTOR SWITCH3-POSITION SELECTOR SWITCH HAND-OFF-AUTOMATICCONTACTORCR-CONTROL RELAY; TD-TIME DELAY RELAY;UV-UNDERVOLTAGE RELAY; M-MOTOR CONTACTOR;RELAY COILSYMBOLDESCRIPTIONSYMBOLS LEGEND - POWERFLAME DETECTORGAS DETECTORSMOKE DETECTORHEAT DETECTORFIRE FIGHTER PHONE JACKFIRE ALARM STROBEFIRE ALARM DUCT SMOKE DETECTOR WITH SAMPLING TUBEFIRE ALARM PULL STATIONFIRE ALARM HORN-STROBEFIRE ALARM PRESSURE SWITCHFIRE ALARM FLOW SWITCHSYMBOLDESCRIPTIONSYMBOLS LEGEND - FIRE ALARMBT - BEAM TRANSMITTERBR - BEAM RECEIVERI - IONIZATIONP - PHOTOELECTRICF - FIXED TEMPERATURER - RATE OF RISE ONLYR/C - RATE COMPENSATIONR/F - RATE OF RISE AND FIXED TEMPERATUREFIRE ALARM TAMPER SWITCHPOST INDICATOR VALVENUMBER INDICATES CANDELLA RATING30TSPSFSFPIVPANELBOARDTRANSFER SWITCH ( AUTO )AMPERES SHORT CIRCUIT AVAILABLE (SYMMETRICAL)XXXSYMBOLDESCRIPTIONSYMBOLS LEGEND - POWERSYMBOLDESCRIPTIONSYMBOLS LEGEND - COMMUNICATIONSCOMMUNICATIONS - OUTLET(#= REPRESENTS THE NUMBER OF COMMUNICATION PORTS. (IE 1,2,3))(W = SINGLE COMMUNICATIONS PORT WALL MOUNTED AT +54" AFF.)(P = PAYPHONE, WALL MOUNTED AT +48" AFF)COMMUNICATIONS - PAINTED FIRE RESISTANT 3/4" PLYWOOD BACKBOARD19" COMMUNICATIONS RACK - FLOOR MOUNTED19" COMMUNICATIONS RACK - WALL MOUNTED3FEEDER TAG - REFER TO FEEDER SCHEDULEWP = WEATHERPROOFOS = OCCUPANCY SENSOR TYPEOP = OCCUPANCY/PHOTOELECTRIC TYPELV = LOW-VOLTAGEWALL SWITCH - SUBSCRIPT SINGLE-POLE WALL SWITCH MOUNT SWITCHES AT 48" AFF. TO CL, UON. 2 = 2-POLE3 = 3-WAYK = KEYED4 = 4-WAYXXSINGLE RECEPTACLE NEMA 5-20R, +18" AFF UONDUPLEX RECEPTACLE NEMA 5-20R, ISOLATED GROUND, +18" AFF UONRECEPTACLE NEMA 5-20R, CONNECTED TO EMERGENCY CIRCUIT, +18" AFF UONRECEPTACLE NEMA 5-20R MOUNTED ABOVE COUNTER. COORDINATE WITHCASEWORK SHOP DRAWINGS AND ARCHITECTURAL DRAWINGS.SPECIAL PURPOSE RECEPTACLE TYPE AS SHOWN ON PLANSCEILING-MOUNTED DUPLEX RECEPTACLE, NEMA 5-20RRECEPTACLE NEMA 5-20R WITH GROUND FAULT CIRCUIT INTERRUPTER, +18"AFF UONPOWER/COMM POLE - FLOOR TO CEILING.SPLIT WIRED DUPLEX RECEPTACLE NEMA 5-20R, +18" AFF UONRECEPTACLE NEMA 5-20R WITH GROUND FAULT CIRCUIT INTERRUPTER,ABOVE COUNTER. COORDINATE WITH CASEWORK SHOP DRAWINGS ANDARCHITECTURAL DRAWINGS.TAMPER RESISTANT RECEPTACLE NEMA 5-20R WITH GROUND FAULT CIRCUITINTERRUPTER, ABOVE COUNTER. COORDINATE WITH CASEWORK SHOPDRAWINGS AND ARCHITECTURAL DRAWINGS.SURFACE MOUNTED FLOOR BOX (PEDESTAL TYPE).PUSH BUTTONRECEPTACLE NEMA 5-20R, ABOVE COUNTER.FIRE ALARM SYSTEM CONTROL PANELESR - ELEVATOR STATUS/RECALLFAC - FIRE ALARM COMMUNICATORFCP - FIRE ALARM CONTROL PANELFSA - FIRE SYSTEM ANNUNCIATORHVA - HVAC OR EXHAUST STAIRWELL PRESSURIZATIONFCPFSD - COMBINATION FIRE SMOKE DAMPERSMOKE DAMPERSDNUMBER INDICATES CANDELLA RATINGFIRE SMOKE DAMPERSMOKE DAMPER#####SINGLE SERVICE OR COMBINATION FLUSH FLOOR POKE THRU. REFER TOFLOOR PLANS FOR DEVICES.SINGLE SERVICE OR COMBINATION FLUSH MOUNTED FLOOR BOX. REFER TOFLOOR PLANS FOR DEVICES.RECEPTACLE NEMA 5-20R, +18" AFF UONTAMPER RESISTANT RECEPTACLE NEMA 5-20R, +18" AFF UONTTTTLOWER CASE LETTER INDICATES SWITCHING GROUPMOUNT SWITCHES AT +48" AFF. TO CL, UON.ANY COMBINATION OF SWITCH TYPES CAN BE USED(IE. 3K = 3-WAY KEYED SWITCH)30CEILING MOUNTED OCCUPANCY SENSOR WITH POWER PACK -PASSIVE INFRARED TYPE UNLESS NOTED:ICS1-1SBNLDECORATIVE PENDENT LIGHTING FIXTURE - TYPE AS NOTEDINTERCOM - OUTLET(D = DESK MOUNTED)(W = WALL MOUNTED AT +54" AFF.)COMMUNICATIONS - MICROPHONE(D = DESK MOUNTED)(W = WALL MOUNTED AT +48" AFF.)DMCOMPUTER NETWORK WIRELESS ACCESS POINT - CEILING MOUNTEDXXXXCRWPAMSYMBOLDESCRIPTIONSYMBOLS LEGEND - WIRING DEVICESGMSDMFSDMCRMCXXXXXX11OSILLUMINATION CONTROL STATIONSWITCH BYPASS DEVICELIGHTING CONTROL SYSTEM POWER PACKTIME CLOCK - TYPE AS NOTEDCOMBINATION BATTERY POWERED EMERGENCY WALLPACKAND ILLUMINATED EXIT SIGNBATTERY-POWERED EMERGENCY WALLPACKILLUMINATED EXIT SIGN - DOUBLE FACEARROW INDICATES DIRECTION OF EGRESS, UNIVERSAL MOUNTILLUMINATED EXIT SIGN - SINGLE FACEARROW INDICATES DIRECTION OF EGRESS, UNIVERSAL MOUNTIN-GROUND LANDSCAPE LUMINAIREPOLE-MOUNTED LUMINAIRENUMBER OF LUMINAIRES AS SHOWN ON PLANSPHOTOELECTRIC CONTROL CEILING MOUNTEDOCCUPANCY SENSOR WALL MOUNTEDPHOTOELECTRIC CONTROL WALL MOUNTEDU= ULTRASONICDT= DUAL TECHNOLOGYUOSDTOSPCOSPCALARM BUZZER WITH STROBEAAALARM BELL WITH STROBEFIRE ALARM HORN WITH CHIMEFIRE ALARM BUZZERFIRE ALARM BELLFFFFIRE ALARM BELL WITH STROBEFFFIRE ALARM BUZZER WITH STROBEFIRE ALARM HORNFD208Y/120V, 3Ø, 4W PANELBOARD480Y/277V, 3Ø, 4W PANELBOARDEQUIPMENT CABINET - TYPE AS NOTED SUNSET NEIGHBORHOODPARK 600 Stewart St., Ste 1400Seattle, Washington 98101Tel206.267.1700Fax206.267.1701ELECTRICAL LEGEND ABBREVIATIONSGENERAL NOTES:1. PROVIDE 3/4" CONDUIT & #12 CONDUCTORS UNLESS NOTED OTHERWISE. PROVIDEONE NEUTRAL CONDUCTOR FOR EACH UNGROUNDED CONDUCTOR OF SINGLEPHASE MULTIWIRE BRANCH CIRCUITS. DO NOT SHARE NEUTRAL CONDUCTORS.2. EACH FEEDER AND BRANCH CIRCUIT CONDUITS SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR SIZED IN ACCORDANCE WITH NFPA 70, ARTICLE 2503.ALL EXISTING ELECTRICAL EQUIPMENT IN PORTIONS OF THE BUILDING NOT BEING REMODELED SHALL BE LEFT IN WORKING CONDITION. RESTORE ANY CIRCUITS INTERRUPTED.4.THE FOLLOWING IS PART OF THIS PROJECT AND ALL COSTS PERTAINING THERETO SHALL BE INCLUDED IN THE BASE BID:1.a.NEW ELECTRICAL EQUIPMENT AND APPARATUS SHALL BE COORDINATED ANDCONNECTED INTO THE EXISTING SYSTEM AS REQUIRED.1.b.POWER WIRING AND CABLE INSTALLATIONS SHALL BE CONCEALED ABOVEACCESSIBLE CEILINGS AND IN WALLS. EXPOSED WIRING SHALL BE INSTALLED INAPPROVED SURFACE METAL RACEWAY WHERE INDICATED.1.c.WHERE EXISTING CONDUITS ARE INDICATED FOR REUSE, FIELD VERIFYINTEGRITY OF REUSED RACEWAYS PRIOR TO INSTALLATION OF CONDUCTORS.PROVIDE NEW RACEWAYS WHERE EXISTING ARE UNUSABLE.1.d.LOCATIONS OF ALL WALL MOUNTED DEVICES SUCH AS SWITCHES,RECEPTACLE, AND OUTLETS ARE SHOWN DIAGRAMMATICALLY. VISIT THE SITETO CONFIRM EXACT DEVICE LOCATIONS AND COORDINATE INSTALLATIONSWITH FIXED CASEWORK, DOORS AND RELITES.1.e.PROVIDE PENETRATIONS THROUGH WALLS, FLOOR, AND CEILINGS ASREQUIRED. PROVIDE SUITABLE FIRE RATED MATERIALS AND SEAL ALL CEILING,FLOOR, AND WALL PENETRATIONS TO MATCH FIRE RATING OF SURFACESPENETRATED.@ ATA/CAIR CONDITIONING(ER)A (AMP)AMPEREACABOVE COUNTER, ALTERNATING CURRENTAFFABOVE FINISHED FLOORAHJLOCAL AUTHORITY HAVING JURISDICTIONAICAMPERES INTERRUPTINGAL or ALUMALUMINUMALTALTERNATEANNANNUNCIATORARCHARCHITECT; ARCHITECTURALAUTOAUTOMATICAUXAUXILIARYAWGAMERICAN WIRE GAUGEBKBDBACKBOARDBKRBREAKERBLDGBUILDINGCCONDUITCABCABINETCAPCAPACITYCBCIRCUIT BREAKERCKTCIRCUITCLGCEILINGCLRCLEARCOLCOLUMNCOMCOMMUNICATIONCTCURRENT TRANSFORMERCUCOPPERDISC SWDISCONNECT SWITCHDISCDISCONNECTDNDOWNDWGDRAWINGE (E)EXIST, EASTEDHELECTRIC DUCT HEATEREFEXHAUST FANEGCEQUIPMENT GROUNDING CONDUCTORELELEVATIONELECELECTRIC(AL)ELEVELEVATOREMEMERGENCYEMTELECTRICAL METALLIC TUBINGENCLENCLOSUREENTRENTRANCEEPEXPLOSION PROOFEPOEMERGENCY POWER OFFEQUIP/EQPEQUIPMENTEWCELECTRIC WATER COOLEREWHELECTRIC WATER HEATEREXHEXHAUSTEXTEXTERIOREXISTEXISTINGFFAHRENHEIT/FUSEFAFIRE ALARMFCFOOTCANDLEFCPFIRE ALARM SYSTEM CONTROL PANELFCUFAN COIL UNITFDFIRE DAMPERFDRFEEDERFIXTFIXTUREFLAFULL LOAD AMPSFSAFIRE SYSTEM ANNUNCIATORFSDFIRE/SMOKE DAMPERFTBFLUIDIZED THERMAL BACKFILLGECGROUNDING ELECTRODE CONDUCTORGFCIGROUND FAULT CIRCUIT INTERRUPTERH HEIGHTHOAHAND OFF AUTOMATICHPHORSEPOWERHRHOURHTHEIGHTHWHOT WATERHZHERTZIBCINTERNATIONAL BUILDING CODEICINTERCOMIESNAILLUMINATING ENGINEERING SOCIETY OFNORTH AMERICAIEEEINSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERSIGISOLATED GROUNDIMCINTERMEDIATE METAL CONDUITJB or J-BOXJUNCTION BOXKCMILTHOUSAND CIRCULAR MILLSKVAKILOVOLT AMPERESKVARKILOVOLT AMPERES REACTIVEKWKILOWATTKWHKILOWATT HOURLBSPOUNDSLFLINEAR FEET (FEET)LRALOCKED ROTOR AMPSLSLIFE SAFETYLTLIGHTLTGLIGHTINGLVLOW VOLTAGEMAGMAGNETICMANMANUALMAXMAXIMUMMCAMINIMUM CIRCUIT AMPACITYMCBMAIN CIRCUIT BREAKERMECHMECHANICALMHMETAL HALIDE / MANHOLEMINMINIMUMMISCMISCELLANEOUSMLOMAIN LUG ONLYMOCPMAXIMUM OVERCURRENT PROTECTIONMSMAGNETIC STARTERMTDMOUNTEDMTGMOUNTINGMTR MOTORNNORTH; NEUTRALN/ANOT APPLICABLENCNORMALLY CLOSEDNECNATIONAL ELECTRICAL CODENEMANATIONAL ELECTRIC MANUFACTURERSASSOCIATIONNESCNATIONAL ELECTRICAL SAFETY CODENEUTNEUTRALNFPANATIONAL FIRE PROTECTION AGENCYNICNOT IN CONTRACTNONORMALLY OPENNTSNOT TO SCALEOCON CENTEROFCIOWNER FURNISHED CONTRACTORINSTALLEDOLOVERLOADOSOPTIONAL STANDBYPPOLE; PHASE; PRIMARYPAPUBLIC ADDRESSPARPARALLELPBPULL BOXPEPHOTO ELECTRICPFPOWER FACTORPHPHASEPIVPOST INDICATOR VALVEPNLPANELPOCPOINT OF CONNECTIONPSEPUGET SOUND ENERGYPWRPOWERQTYQUANTITYR (R)RELOCATE (D)RAD RADIUSRECPTRECEPTACLEREFREFRIGERATORRLARUNNING LOAD AMPSRPMREVOLUTIONS PER MINUTESSOUTHSECSECURITY; SECOND (ARY)SDSMOKE DETECTORSECTSECTIONSFSUPPLY FANSHTSHEETSPECSPECIFICATIONSPDSURGE PROTECTIVE DEVICESQSQUARESWSWITCHSWBDSWITCHBOARDSYMSYMMETRICALSYSSYSTEMTTHERMOSTATTBTERMINAL BOXTCTIME CLOCKTELTELEPHONETVTELEVISIONTYPTYPICALUBCUNIFORM BUILDING CODEUFCUNIFORM FIRE CODEUG UNDERGROUNDUHUNIT HEATERULUNDERWRITERS LABORATORIESUONUNLESS OTHERWISE NOTEDUV UNIT VENTILATORVVOLTVAVVARIABLE AIR VOLUMEVELVELOCITYVFDVARIABLE FREQUENCY DRIVEVMVOLTMETERVOLVOLUMEWWATT, WESTW/WITHW/OWITHOUTWHMWATT HOUR METERWPWEATHERPROOFXREACTANCEXFMRTRANSFORMERXMTRTRANSMITTERZIMPEDANCE&ANDI.E.:THAT ISI.G.:FOR EXAMPLE#NUMBERCONDUIT - CONCEALED IN OR UNDER FLOOREXISTING TO BE REMOVEDCONDUIT OR CABLE VERTICAL DOWNCONDUIT STUB - TERMINATE WITH BUSHING OR CAP IF UNDERGROUNDCONDUIT OR CABLE VERTICAL UPCONDUCTORS - CONNECTEDCONDUCTORS - NOT CONNECTEDLOW-VOLTAGE WIRING (CLASS B)CONDUIT - ROUTED UNDERGROUNDCONDUIT SEALJUNCTION BOXMANHOLE HANDHOLE PULLBOX - SIZE AS INDICATED OR AS REQUIRED BY CODESYMBOLDESCRIPTIONSYMBOLS LEGEND - GENERALA-1,3,5BREAK LINECABLE TRAYEXPANSION FITTINGMINIMUM 3/4" CONDUIT CONCEALED IN CEILING SPACE OR IN WALL MINIMUM3/4" WITH #12 AWG CONDUCTORS WITH DEDICATED NEUTRAL EACHCIRCUIT, UNLESS OTHERWISE NOTED ON PLAN.PROVIDE EQUIPMENT GROUNDING CONDUCTORS SIZED PER NFPA 70.HOME RUN TO SOURCE OF SUPPLYPANEL DESIGNATIONBRANCH CIRCUIT NUMBERSFLEXIBLE METAL CONDUITJMHHHPBDRAWING CONSTRUCTION ("FLAG") NOTEMATCHLINEREVISION CLOUD (ENCIRCLES DRAWING CHANGES MADE SINCETHE PREVIOUS RELEASE)DETAIL REFERENCESECTION REFERENCEELEVATION REFERENCEREVISION REFERENCENORTH REFERENCE1N1XXX.XXXXX.XXXXX.XXSYMBOLDESCRIPTIONSYMBOLS LEGEND - GENERALSECTION IDENTIFICATION NUMBERSHEET WHERE SECTION IS DRAWNELEVATION IDENTIFICATION NUMBERSHEET WHERE ELEVATION IS DRAWNDETAIL IDENTIFICATION NUMBERSHEET WHERE DETAIL IS DRAWNEQUIPMENT IDENTIFIERLIGHT LINEWEIGHT INDICATES EXISTING INFORMATIONHEAVY LINEWEIGHT INDICATES NEW WORKPOINT OF CONNECTION (POC) BETWEEN NEW AND EXISTINGEQUIPMENT IDENTIFIER (XX = ABBREVIATIONY = EQUIPMENT SCHEDULE NUMBER)X-XXXXXDNRACEWAY/CABLE/CONDUCTOR ROUTING IDENTIFIER-REFER TO RACEWAY/CABLE/CONDUCTOR SCHEDULEXXX SUNSET NEIGHBORHOODPARK 600 Stewart St., Ste 1400Seattle, Washington 98101Tel206.267.1700Fax206.267.1701ELECTRICAL LEGEND,ABBREVIATIONS, & GENERAL NOTES 2 A 1 5 6 978 10 11 12 B C 3 D E 4 PNL DPL-1 LC-1 OS DT PC OS PC PNL DPL-2 EW1 EW1W3 TYP W3 TYP S3 TYP S3E DPL1-9,11 11 13 13 13 13 13 13 13 6 6 1 2 2 2 3 3 11 1111 11 11 9 LC-2 4 M119EW2EW2 DPL2-11,13 S3 W3E W3E PC2 5 5S3E C DT 1 1 1 1 5 PC 5 GENERAL NOTES: 1.CONFORM WITH NEC AND STATE OF WASHINGTON CODES AND ORDINANCES. 2.OBTAIN THE REQUIRED PERMITS AND INSPECTIONS FOR ELECTRICAL WORK. 3.ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE PROJECT SCHEDULE. COORDINATE INSTALLATION WITH GENERAL CONTRACTOR AND OTHER TRADES TO ENSURE PROJECT MILESTONES ARE MET. 4.ANY EQUIPMENT HAVING ELECTRICAL CONNECTIONS THAT REQUIRE DISCONNECTING AND/OR RE-CONNECTING AS A RESULT OF CONSTRUCTION SHALL BE INCLUDED AS A PART OF THIS CONTRACT. 5.UNLESS OTHERWISE NOTED, WIRING SHALL BE 3/4"C, 2#12, 1#12 GND THHN/THWN COPPER CONDUCTOR. 6.MOUNT SWITCHES 48" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. 7.PROVIDE UNSWITCHED CONDUCTORS TO EMERGENCY LIGHTING FIXTURES WITH SELF CONTAINED BATTERY BACKUP FOR CIRCUIT MONITORING. 8.CONDUIT RESTROOMS AND SIMILAR AREAS SHALL BE CONCEALED INSIDE WALLS OR ABOVE CEILINGS WHENEVER POSSIBLE. 9.CONDUIT 2" AND BELOW MAY BE ELECTRICAL METALLIC TUBING (EMT). 10.DYMO LABEL EACH JUNCTION BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 11.POST NEW TYPE WRITTEN PANEL SCHEDULES UPON COMPLETION OF JOB. 12.PROVIDE LAMINATED PHENOLIC NAMEPLATES FOR LIGHTING CONTROL PANELS AS INDICATED. 13.REFER TO CH2M ELECTRICAL DRAWING E-4 FOR PANEL SCHEDULES. 14.REFER TO SHEET E400 FOR LIGHTING FIXTURE SCHEDULE. REFERENCE NOTES: ALL EXTERIOR BUILDING LIGHTING IS CONTROLLED BY CL-1 VIA CONTROL CIRCUIT C8: DIRECTLY IN THE NORTH BUILDING AND INDIRECTLY VIA [C2] TO MAGNETIC CONTACTOR LC-2 IN THE SOUTH BUILDING. SEE CH2M DRAWING E4 FOR CIRCUITS TO LC'S. PROVIDE LINE VOLTAGE INDOOR 0-10V PHOTOCELL LEVITON #PCC1D-00W OR APPROVED EQUAL. PROVIDE CEILING MOUNTED LINE VOLTAGE MULTI-TECHNOLOGY VACANCY SENSOR.. LEVITON #ODC10-MWD OR APPROVED EQUAL. LIGHTING CONTACTOR LC-2. REFER TO CH2M DRAWING E4 AND E5. PROVIDE 0-10V CLASS 2 WIRING AS REQD. REFER TO MFRS WRITTEN INSTRUCTIONS. REFER TO CH2M DRAWING E4. 1 2 3 4 5 6 SUNSET NEIGHBORHOOD PARK 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 LIGHTING PLAN SCALE:NLIGHTING PLAN 1/4" = 1'-0" 1 4 2 3 6 5 7 UG UG UG UG UGUG UG UG UG UG UG UG UG UG UG PB UG UG UGP1 TYP 1 2 3 4 4 4 4 4 4 4 3 3 3 3 3 3 GENERAL NOTES: 1.CONFORM WITH NEC AND STATE OF WASHINGTON CODES AND ORDINANCES. 2.OBTAIN THE REQUIRED PERMITS AND INSPECTIONS FOR ELECTRICAL WORK. 3.ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE PROJECT SCHEDULE. COORDINATE INSTALLATION WITH GENERAL CONTRACTOR AND OTHER TRADES TO ENSURE PROJECT MILESTONES ARE MET. 4.UNLESS OTHERWISE NOTED, WIRING SHALL BE 3/4" GRS CONDUIT, 2#12, 1#12 GND THHN/THHW COPPER CONDUCTOR. 5.MOUNT LIGHTING FIXTURES 7'-6" ABOVE GRADE UNLESS OTHERWISE NOTED. 6.DYMO LABEL EACH JUNCTION BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 7.POST NEW TYPE WRITTEN PANEL SCHEDULES UPON COMPLETION OF JOB. 8.REFER TO CH2M ELECTRICAL DRAWING E-2 FOR LIGHTING CIRCUITS & HOMERUN TO PANEL. 9.REFER TO SHEET E400 FOR LIGHTING FIXTURE SCHEDULE. REFERENCE NOTES: SEE CH2M DRAWING E-2. PROVIDE PRECAST CONCRETE PULLBOX. PROVIDE 3/4" SCHED 40 UG PVC CONDUIT WITH 2#12 XHHW, 1#12 XHHW GND. PROVIDE 3/4" GRS CONDUIT STUB UP & #12 CONDUCTORS AT COLUMN BASE. COORD WITH STRUC. ROUTE 3/4" GRS CONDUIT & #12 CONDUCTORS CONCEALED WITHIN COLUMN WRAP TO LIGHTING FIXTURE. PROVIDE WP J-BOX & GRS LB AS REQD. 1 2 3 4 SUNSET NEIGHBORHOOD PARK 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 PERGOLA LIGHTING PLAN SCALE:NPERGOLA LIGHTING PLAN 1/4" = 1'-0" 2 A 1 5 6 978 10 11 12 B C 3 D E 4 J J ERU 1 M ES 16 7 12 17 1 2 2 4 7 EWH 1B J 6,8 14 3 6 5 J ES 2 2 PANEL DPL-1LC-1 ACCESS CONTROL CABINET IRRIGATION CONTROLLER PANEL DPL-2 EWH 1A J 2,4 3 DPL2-2,4 DPL2-12,14,16 9 9 4 J 16 1 DPL2-6,8,10 9 9 9 WH 1 HD 1 12 J 10WP 9 9 EWH 2B J 6,8 3 WH 2 10DPL1-6,8 ERU 214 6 5 EWH 2A J 2,4 3 DPL1-2,4 7 7 7 J10 WP 15 7 13 DPL1- 13,15,17 DPL1-7 DPL1- 14,16 DPL1- 10,12 TELEMETRY BACKBOARD 11 UTILITY METER 10 12 12 REFERENCE NOTES PROVIDE CONNECTION FOR CONNECTION HAND DRYER. REFER TO EQUIP SCHEDULE. COORD WITH ARCH DWGS FOR EXACT LOCATION PRIOR TO ROUGH-IN. PROVIDE DOOR STRIKE & 3/4" CO WITH PULL STRING TO ACCESS CONTROL PANEL. COORD WITH ARCH DWGS & ACCESS CONTROL SYSTEM SUPPLIER. PROVIDE CONNECTION FOR ELECTRIC WALL HEATER EH-1. REFER TO EQUIP SCHEDULE. COORD WITH ARCH DWGS FOR EXACT LOCATION PRIOR TO ROUGH-IN. PROVIDE TAMPER RESISTANT GFCI TYPE NEMA 5-20R. MOUNT @ 42"AFF. COORD WITH ARCH DWGS FOR EXACT LOCATION PRIOR TO ROUGH-IN. PROVIDE CONNECTION FOR ERU-1. REFER TO EQUIP SCHEDULE. ROUTE ENERGY RECOVERY UNIT TO PANEL VIA LIGHTING CONTROL PANEL LCP-1 0-10V DIMMING RELAY. PROVIDE CLASS 2 WIRING AS REQD. PROVIDE AUTO ON CONTROL VIA ROOM OCCUPANCY SENSOR. PROGRAM FOR 30 MINUTE DELAY OFF AFTER OCCUPANCY SENSOR DETECTS ROOM IS UNOCCUPIED. PROVIDE DUPLEX RECEPT @ 48"AFF FOR IRRIGATION CONTROLLER. LIGHTING CONTROL CABINET LC-1. REFER TO CH2M DRAWING E-4 & E-5. PANEL. REFER TO CH2M DRAWING E-4. REFER TO CH2M DRAWING E-4. REFER TO CH2M DRAWING E-5. J-BOX FOR DRINKING FOUNTAIN HEAT TRACE. COORD WITH MECH. REFER TO CH2M DRAWING E-5. 1 GENERAL NOTES: 1.CONFORM WITH NEC AND STATE OF WASHINGTON CODES AND ORDINANCES. 2.OBTAIN THE REQUIRED PERMITS AND INSPECTIONS FOR ELECTRICAL WORK. 3.ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE PROJECT SCHEDULE. COORDINATE INSTALLATION WITH GENERAL CONTRACTOR AND OTHER TRADES TO ENSURE PROJECT MILESTONES ARE MET. 4.ANY EQUIPMENT HAVING ELECTRICAL CONNECTIONS THAT REQUIRE DISCONNECTING AND/OR RE-CONNECTING AS A RESULT OF CONSTRUCTION SHALL BE INCLUDED AS A PART OF THIS CONTRACT. 5.ALL CONDUCTORS SHALL BE COPPER WITH THHN OR XHHW INSULATION UNLESS NOTED OTHERWISE. 6.REFER TO CH2M ELECTRICAL DRAWING E-4 FOR PANEL SCHEDULES. 7.REFER TO DRAWING E400 FOR EQUIPMENT SCHEDULE. 2 3 4 5 6 7 8 9 10 11 12 SUNSET NEIGHBORHOOD PARK 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SCALE:NPOWER & SIGNAL PLAN 1/4" = 1'-0" POWER & SIGNAL PLAN SUNSET NEIGHBORHOODPARK 600 Stewart St., Ste 1400Seattle, Washington 98101Tel206.267.1700Fax206.267.1701PROJECT_NAME FILECODE ELECTRICAL SCHEDULESAND DETAILS SUNSET NEIGHBORHOOD PARK 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701PROJECT_NAMEFILECODEELECTRICAL NREC FORMS