HomeMy WebLinkAboutAdministrative Short Plat Report 16-000967_FINALDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Project Location Map
Admin Short Plat Report
A. ADMINISTRATIVE REPORT & DECISION
DECISION: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED
REPORT DATE: April 24, 2017
Project Name: Aberdeen Ave Short Plat
Owner/Applicant: PMP Investors LLC, 8638 138th Pl. SE, Newcastle, WA 98059
Contact: Carmel Gregory, CG Engineering, 250 4th Ave S., Ste 200, Edmonds, WA 98020
File Number: LUA16-000967, SHPL-A, MOD
Project Manager: Alex Morganroth, Associate Planner
Project Summary:
The applicant is requesting approval of a 2-lot short plat. The site is 16,161
square feet (0.37 acres) and is located at 1824 Aberdeen Ave NE (APN
3343901606). The project site is located within the Residential-8 (R-8) zone and
would be for the future development of two single-family homes. The proposed
lots include a 5,677 square foot lot (Lot 1) and a 7,903 square foot lot (Lot 2)
with a net density of 6.5 du/ac. Tract A is proposed as a 2,581 square foot
driveway to be used for access. The property is bordered to the west by
Aberdeen Ave NE, and to the east, north, and south by single family residential
lots. All existing structures on the site will be removed to accommodate the
proposed lot division. Access to both lots will be provided via the 20 foot wide
shared driveway tract accessed off of Aberdeen Ave NE. The applicant is
proposing to retain the two existing onsite trees. The native soils consist
primarily of Indianola Loamy Sand. A Wellhead Protection Area Zone 2 was
mapped on the subject property. The applicant has submitted a Geotechnical
Engineering Study and a Preliminary Technical Information Report with the
application.
Project Location: 1824 Aberdeen Avenue NE, Renton, WA 98057 (APN 334390106)
Site Area: 16,128 square feet (0.37 acres)
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 2 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
B. EXHIBITS:
Exhibit 1: Staff Report
Exhibit 2: Short Plat Plan (Sheets 1, 2, & 3)
Exhibit 3: Neighborhood Detail Map
Exhibit 4: Erosion Control / Grading and Drainage / Utility Plan (Sheets C.1, C3.1, & C4.1)
Exhibit 5: Conceptual Landscape Plan (Sheet L1.0)
Exhibit 6: Preliminary Geotechnical Report prepared by Nelson Geotechnical Associates, Inc
(dated October 17, 2016)
Exhibit 7: Preliminary Technical Information Report prepared by CG Engineering, Inc. (dated
February 16, 2017)
Exhibit 8: Construction Mitigation Description
Exhibit 9: Modification of Street Standards Request
Exhibit 10:
Exhibit 11:
Modification of Shared Driveway Standards Request
CI-97 Shared Driveway Landscape Standards
Exhibit 12:
Exhibit 13:
Advisory Notes to Applicant
Renton Fire Authority Email in Support of Variance
C. GENERAL INFORMATION:
1. Owner(s) of Record: PMP Investors LLC, 8638 138th Pl, Newcastle, WA
98059
2. Zoning Classification: Residential-8 (R-8)
3. Comprehensive Plan Land Use
Designation:
Residential Medium Density (RMD)
4. Existing Site Use: Single Family Residence
5. Critical Areas: Wellhead Protection Area Zone 2
6. Neighborhood Characteristics:
a. North: Single Family Residential, R-8
b. West: Single Family Residential, R-8
c. South: Single Family Residential, R-8
d. East: Single Family Residential, R-8
7. Site Area: 0.37 acres
D. HISTORICAL/BACKGROUND:
Action Land Use File No. Ordinance No. Date
Comprehensive Plan N/A 5758 06/22/2015
Zoning N/A 5758 06/22/2015
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 3 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
Gebenini Annexation A-003-60 1822 03/31/1960
E. PUBLIC SERVICES:
1. Existing Utilities
a. Water: Water service is provided by the City of Renton.
b. Sewer: Wastewater service is provided by the City of Renton.
c. Surface/Storm Water: Runoff from the site sheet flows from east to west at an average of four
percent towards Aberdeen Avenue NE, where it flows north along the roadway edge and eventually
enters an existing 18-inch storm drainage within Aberdeen Avenue NE.
2. Streets: The proposed development fronts Aberdeen Ave NE to the east, which is classified as a Collector
Arterial Street with an existing right of way (ROW) width of 60 feet as measured using the King County
Assessor’s Map. There are no existing frontage improvements along the street frontage of Aberdeen Ave
NE.
3. Fire Protection: Renton Regional Fire Authority.
F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE:
1. Chapter 2 Land Use Districts
a. Section 4-2-020: Purpose and Intent of Zoning Districts
b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations
c. Section 4-2-110: Residential Development Standards
d. Section 4-2-115: Residential Design and Open Space Standards
2. Chapter 4 City-Wide Property Development Standards
3. Chapter 6 Streets and Utility Standards
a. Section 4-6-060: Street Standards
4. Chapter 7 Subdivision Regulations
a. Section 4-7-070: Detailed Procedures for Short Subdivision
5. Chapter 9 Permits-Specific
a. Section 4-9-250: Variances, Waivers, Modifications, and Alternates
6. Chapter 11 Definitions
G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN:
1. Land Use Element
H. FINDINGS OF FACT (FOF):
1. The Planning Division of the City of Renton accepted the above master application for review on
December 23, 2016 and determined the application complete on January 6, 2017. The project was put
on hold February 2, 2017 and taken off hold on February 28, 2017. The project complies with the 120-
day review period.
2. The project site is located at 1824 Aberdeen Ave NE, Renton, WA 98059 (APN 3343901606), between NE
20th St and NE 18th Pl (Exhibits 2 and 3).
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 4 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
3. The project site contains a 1,140 square foot single family home, a 722 square foot detached garage, and
a 739 square foot shop structure (Exhibit 2), which are proposed to be removed.
4. Access to the site would be provided from Aberdeen Ave NE via a shared driveway tract used to access
both new lots. No right-of-way dedication would be dedicated along Aberdeen Ave NE (Exhibits 2 and 9).
5. The property is located within the Residential Medium Density (RLD) Comprehensive Plan land use
designation.
6. The site is located within the Residential-8 (R-8) zoning classification.
7. There are two (2) significant tree located within the proposed development area that are proposed to be
retained as part of the short plat (Exhibit 5).
8. There is a Wellhead Protection Area Zone 2 mapped on the subject property.
9. The project is estimated to require about 135 cubic yards of cut and fill.
10. No public or agency comments were received.
11. Representatives from various city departments have reviewed the application materials to identify and
address issues raised by the proposed development. These comments are contained in the official file,
and the essence of the comments has been incorporated into the appropriate sections of this report and
the Departmental Recommendation at the end of this report (Exhibit 12).
12. Comprehensive Plan Compliance: The site is designated Residential Medium Density (RMD) on the City’s
Comprehensive Plan Map. The purpose of the RMD designation is to provide transition to the rural area,
and to provide for larger lot housing to allow for a range of lifestyles. The proposal is compliant with the
following Comprehensive Plan land use policies if all conditions of approval are met:
Compliance Comprehensive Plan Analysis
Policy L-3: Encourage infill development of single-family units as a means to meet
growth targets and provide new housing.
Goal L-I: Utilize multiple strategies to accommodate residential growth, including:
Development of new single-family neighborhoods on large tracts of land outside
the City Center,
Infill development on vacant and underutilized land in established neighborhoods
and multi-family areas.
Goal L-BB: Maintain a high quality of life as Renton grows by ensuring that new
development is designed to be functional and attractive.
Goal L-FF: Strengthen the visual identity of Renton and its Community Planning Areas
and neighborhoods through quality design and development.
Policy L-49: Address privacy and quality of life for existing residents by considering
scale and context in infill project design.
13. Zoning Development Standard Compliance: The site is classified Residential-8 (R-8) on the City’s Zoning
Map. The R-8 designation is intended to create opportunities for new single family residential
neighborhoods and to facilitate high-quality infill development that promotes reinvestment in existing
single family neighborhoods. It is intended to accommodate uses that are compatible with and support
a high-quality residential environment and add to a sense of community. The proposal is compliant with
the following development standards if all conditions of approval are met:
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 5 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
Compliance R-8 Zone Development Standards and Analysis
Density: The minimum density required in the R-8 zone is 4.0 dwelling units per acre.
The maximum density permitted is 8.0 dwelling units per net acre. Net density is
calculated after the deduction of sensitive areas, areas intended for public right-of-
way, and private access easements.
Calculations for minimum or maximum density which result in a fraction that is 0.50
or greater shall be rounded up to the nearest whole number. Those density
calculations resulting in a fraction that is less than 0.50 shall be rounded down to the
nearest whole number.
Staff Comment: Based on a net density of 13,580 square feet (16,161 sf gross density
– 2,581 sf driveway tract), the proposal for 2 residential lots on the project site would
result in a net density of 6.42 dwelling units per acre (2 lots / 0.312 acres = du/ac),
which meets the minimum and maximum density requirements of the R-8 zone.
Lot Dimensions: The minimum lot size permitted in the R-8 zone is 5,000 sq. ft. A
minimum lot width of 50 feet is required (80 feet for corner lots) and a minimum lot
depth of 80 feet is required.
The following table identifies the proposed approximate dimensions for Lots 1-2.
Proposed Lot Lot Size (sq. ft.) Lot Width (feet) Lot Depth (feet)
Lot 1 5,677 44.01 129.03
Lot 2 7,903 64.14 123.49
Tract A 2,581 20.00 129.03
Staff Comment: According to RMC 4-2-110D.31, in order to meet the variation
requirements of RMC 4-2-115, lot dimensions and setbacks are allowed to be
decreased and/or increased, provided that when averaged the applicable lot standards
of the zone are met. The average width of Lot 1 and Lot 2 is 54.01 feet (44.01
feet/64.01 feet). Therefore, the proposed lots would comply with the minimum lot size,
width, and depth requirements of the R-8 zone (Exhibit 2). Tract A is a joint use access
and utility tract located along the south property line that measures 20 feet wide, and
is required to comply with the shared driveway standards. .
Compliant if
conditions of
approval are
met
Setbacks: The required setbacks in the R-8 zone are as follows: front yard is 20 feet,
side yard is 5 feet, side yard along the street 15 feet, and the rear yard is 20 feet.
Staff Comment: If retained, the existing residence and garage on proposed Lot 1 and
the existing shop on Lot 2 would not comply with Residential-8 (R-8) setback
requirements. Therefore, staff recommends as a condition of approval that the
applicant obtain a demolition permit and complete a final inspection from the City for
the removal of the residence, garage, and shop located on Lots 1 and 2 in order to
comply with Residential-8 (R-8) setbacks of the zone prior to final plat approval. The
new residential lots appear to contain adequate area to accommodate all the required
setback areas and provide a sufficient sized building footprint. Compliance with
building setback requirements for the residences proposed to be constructed on Lot 1
and Lot 2 would be verified at the time of building permit review.
Compliance
not yet
demonstrated
Building Standards: The R-8 zone has a maximum building coverage of 50% and a
maximum impervious surface coverage of 65%. In the R-8 zone, a maximum building
height of 2 stories with a wall plate height of 24 feet is permitted. Roofs with a pitch
equal to or greater than 4:12 may project an additional six (6) vertical feet from the
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 6 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
maximum wall plate height; common rooftop features, such as chimneys, may project
an additional four (4) vertical feet from the roof surface.
The topmost surface of roofs pitched less than 4:12, and rooftop decks shall be below
the maximum wall plate height unless such surfaces are stepped back one-and-a-half
(1.5) horizontal feet from each minimum building setback line for each one vertical
foot above the maximum wall plate height, in which case they may extend up to six
(6) vertical feet above the maximum wall plate height. Railings located above the
maximum wall plate height and not stepped back shall be at least fifty percent (50%)
transparent.
Wall plates supporting a roof with only one (1) sloping plane (e.g., shed roof) may
exceed the stated maximum if the average of wall plate heights is equal or less than
the maximum wall plate height allowed.
Staff Comment: Building height, building coverage and impervious surface coverage
for the new single family residences would be verified at the time of building permit
review.
Compliant if
conditions of
approval are
met
Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot
landscape strip along all public street frontages. Additional minimum planting strip
widths between the curb and sidewalk are established according to the street
development standards of RMC 4-6-060. Street trees and, at a minimum,
groundcover, are to be located in this area when present. Spacing standards shall be
as stipulated by the Department of Community and Economic Development, provided
there shall be a minimum of one street tree planted per address. Any additional
undeveloped right-of-way areas shall be landscaped unless otherwise determined by
the Administrator. Where there is insufficient right-of-way space or no public
frontage, street trees are required in the front yard subject to approval of the
Administrator. A minimum of two (2) trees are to be located in the front yard prior to
final inspection for the new Single Family Residence. In addition, CI-97 requires the
installation of an eight (8) foot wide landscaping area between the driveway tract and
the adjacent property (Exhibit 11). The landscape plan does not show the required
landscape area within the tract and staff has requested the applicant install a reduced,
four (4) foot wide landscape area (FOF 20).
Staff Comment: A Conceptual Landscape Plan, prepared by Origin Design Group
(Exhibit 5), was submitted with the short plat application materials. A partial 10-foot
onsite landscape strip is proposed along the street frontage of Aberdeen Ave NE. A
Plant Schedule was included on the Landscape Plan, the following trees and plants are
proposed within the onsite landscape strip: Flowering Chanticleer Pear, Gulf Stream
Heavenly Bamboo, Otto Luyken Laurel, Goldflame Spirea, and Dwarf Japanese Holly.
The Landscape Plan does not show the landscaping in the ROW area as required by
code. The landscape plan does not show the required landscape area within the tract
and staff has requested the applicant install a reduced, four (4) foot wide landscape
area (FOF 20). In addition, two (2) trees are required to be located in the front yard of
Lot 2 as it does not a public street frontage. Therefore, Staff recommends, as a
condition of approval, that the applicant submit a final detailed landscape plan that
complies with RMC 4-8-120D.12 at the time of utility construction permit application
to the current planning project manager for review and approval.
The applicant would be required to record a note on the face of the plat that executes
a shared maintenance agreement for equal ownership and maintenance
responsibilities for improvements in Tract A. A draft version of a shared maintenance
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 7 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
agreement shall be submitted for review and approval by the current planning project
manager prior to short plat recording.
If the applicant creates a home owners association for ownership and maintenance
responsibilities for improvements in Tract A, then HOA documents shall be submitted
for review and approval by the current planning project manager and the City Attorney
prior to short plat recording.
The applicant would be required to record a note on the face of the plat that executes
a shared maintenance agreement for equal ownership and maintenance
responsibilities for improvements in Tract A. A draft version of a shared maintenance
agreement shall be submitted for review and approval by the current planning project
manager prior to short plat recording.
Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations
require the retention of 30 percent of trees in a residential development.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy;
significant trees on slopes greater than twenty percent (20%); Significant trees
adjacent to critical areas and their associated buffers; and Significant trees over sixty
feet (60') in height or greater than eighteen inches ( 18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be
preserved; other significant native evergreen or deciduous trees; and other significant
non-native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have
been evaluated for retention and are not able to be retained, unless the alders and/
or cottonwoods are used as part of an approved enhancement project within a critical
area or its buffer.
A minimum tree density shall be maintained on each residentially zoned lot. For
detached single family development, the minimum tree density is two (2) significant
trees for every five thousand (5,000) square feet. The tree density may consist of
existing trees, replacement trees, trees required pursuant to RMC 4-4-070F.1, Street
Frontage Landscaping Required, or a combination.
Staff Comment: A conceptual Landscape Plan (Exhibit 5) was submitted with the
project application materials. According to the Plan, two significant conifer trees are
proposed to be retained onsite. No other significant trees were located onsite. As a
result, the applicant is proposing to retain 100 percent of the significant trees, thereby,
meeting the minimum tree retention requirements of the R-8 zone.
In addition, to complying with the minimum tree retention requirements, the applicant
is required to retain or plant two (2) significant trees, or gross equivalent caliper inches,
per 5,000 square feet of lot area. The conceptual Landscape Plan demonstrates
compliance with minimum tree retention requirements by retaining 100 percent of
significant trees on-site. However, the conceptual Landscape Plat does not
demonstrate compliance with minimum tree density requirements of the zone based
on the proposed size of Lot 1. Staff recommends, as a condition of approval, that the
applicant submit a final detailed landscape plan showing two (2) additional trees on
Lot 1 in order to meet the minimum tree density requirement of four (4) trees. The
gross equivalent caliper inches of retained trees on Lot 2 meets the tree density
requirement for the lot. Onsite landscaping shall be installed prior to final occupancy
for the individual homes and landscaping within the right-of-way shall be installed
prior to short plat recording.
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 8 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
Parking: Parking regulations require that a minimum of two (2) parking spaces be
provided for each detached dwelling.
Driveway cuts are required to be a minimum of 5 feet from property lines and new
driveways may be a maximum of 16 feet in width at the property line. Maximum
driveway slopes shall not exceed fifteen percent (15%); provided, that driveways
exceeding eight percent (8%) shall provide slotted drains at the lower end with
positive drainage discharge to restrict runoff from entering the garage/residence or
crossing any public sidewalk.
Staff Comment: Each lot contains adequate area for the provision of two parking
spaces per dwelling unit, as required by RMC 4-4-80 required parking spaces. The slope
of the proposed driveway tract that will serve both Lot 1 and Lot 2 was identified as
2%. Parking requirements and driveway grades for each of the new residences
proposed would be verified at the time of building permit review. The applicant is
proposing to retain the existing driveway approach on the property, which is located
along the south property line. The width of the future paved driveway to be located in
the tract was not indicated in the application materials, but may not exceed 16 feet at
the property line.
Compliant if
condition of
approval is
met
Fences and Retaining Walls: In any residential district, the maximum height of any
fence, hedge or retaining wall shall be seventy two inches (72"). Except in the front
yard and side yard along a street setback where the fence shall not exceed forty eight
inches (48") in height.
There shall be a minimum three-foot (3') landscaped setback at the base of retaining
walls abutting public rights-of-way.
Staff Comment: No new fences or retaining walls are proposed on the site. Two existing
retaining walls will remain on proposed Lot 1, including one along the south property
line and one along the west property line. Both retaining walls are under four (4) feet
in height and therefore are in compliance with the code. The chainlink fence located
on the north side of the proposed lots is four feet tall and therefore is in compliance
with code. The application materials did not indicate the height of the existing wood
fence along the southern property line of proposed Lot 2. The fence may not exceed
four (4) feet in the front yard setback area of proposed Lot 2.
14. Design Standards: Residential Design and Open Space Standards (RMC 4-2-115) are applicable in the R-
8 zone. The Standards implement policies established in the Land Use Element of the Comprehensive
Plan. Compliance with Site Design Standards must be demonstrated prior to approval of the subdivision.
Compliance with Residential Design Standards would be verified prior to issuance of the building permit
for the new single family homes. The proposal is consistent with the following design standards, unless
noted otherwise:
N/A Lot Configuration: N/A
Compliance
not yet
demonstrated
Garages: One of the following is required; the garage is:
1. Recessed from the front of the house and/or front porch at least eight feet
(8'), or
2. Located so that the roof extends at least five feet (5') (not including eaves)
beyond the front of the garage for at least the width of the garage plus the
porch/stoop area, or
3. Alley accessed, or
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 9 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
4. Located so that the entry does not face a public and/or private street or an
access easement, or
5. Sized so that it represents no greater than fifty percent (50%) of the width of
the front facade at ground level, or
6. Detached.
The portion of the garage wider than twenty six-feet (26') across the front shall be
set back at least two feet (2').
Staff Comment: Compliance for this standard would be verified at the time of building
permit review.
Compliance
not yet
demonstrated
Primary Entry: One of the following is required:
1. Stoop: minimum size four feet by six feet (4' x 6') and minimum height
twelve inches (12") above grade, or
2. Porch: minimum size five feet (5') deep and minimum height twelve inches
(12") above grade.
Exception: in cases where accessibility (ADA) is a priority, an accessible route may be
taken from a front driveway.
Staff Comment: Compliance for this standard would be verified at the time of
building permit review. It should be noted that the Primary Entry of the future new
home on Lot 1 is required to be oriented towards Aberdeen Ave NE, with the garage
oriented towards the shared driveway tract.
Compliance
not yet
demonstrated
Façade Modulation: One of the following is required:
1. An offset of at least one story that is at least ten feet (10') wide and two feet
(2') in depth on façades visible from the street, or
2. At least two feet (2') offset of second-story from first-story on one street
facing façade.
Staff Comment: Compliance for this standard would be verified at the time of
building permit review.
Compliance
not yet
demonstrated
Windows and Doors: Windows and doors shall constitute twenty-five percent (25%)
of all façades facing street frontage or public spaces.
Staff Comment: Compliance for this standard would be verified at the time of
building permit review.
N/A Scale, Bulk, and Character: N/A
Compliance
not yet
demonstrated
Roofs: One of the following is required for all development:
1. Hip or gabled with at least a six to twelve (6:12) pitch for the prominent form
of the roof (dormers, etc., may have lesser pitch), or
2. Shed roof.
Additionally, for subdivisions greater than nine (9) lots: A variety of roof forms
appropriate to the style of the home shall be used.
Staff Comment: Compliance for this standard would be verified at the time of
building permit review.
Compliance
not yet
demonstrated
Eaves: Both of the following are required:
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 10 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
1. Eaves projecting from the roof of the entire building at least twelve inches
(12") with horizontal fascia or fascia gutter at least five inches (5") deep on
the face of all eaves, and
2. Rakes on gable ends must extend a minimum of two inches (2") from the
surface of exterior siding materials.
Staff Comment: Compliance for this standard would be verified at the time of
building permit review.
Compliance
not yet
demonstrated
Architectural Detailing: If one siding material is used on any side of the dwelling that
is two stories or greater in height, a horizontal band that measures at least eight
inches (8") is required between the first and second story.
Additionally, one of the following is required:
1. Three and one half inch (3 ½") minimum trim surrounds all windows and
details all doors, or
2. A combination of shutters and three and one half inches (3 ½") minimum
trim details all windows, and three and one half inches (3 ½") minimum trim
details all doors.
Staff Comment: Compliance for this standard would be verified at the time of
building permit review.
Compliance
not yet
demonstrated
Materials and Color: For subdivisions and short plats, abutting homes shall be of
differing color. Color palettes for all new dwellings, coded to the home elevations,
shall be submitted for approval.
Additionally, one of the following is required:
1. A minimum of two (2) colors is used on the home (body with different color
trim is acceptable), or
2. A minimum of two (2) differing siding materials (horizontal siding and
shingles, siding and masonry or masonry-like material, etc.) is used on the
home. One alternative siding material must comprise a minimum of thirty
percent (30%) of the street facing facade. If masonry siding is used, it shall
wrap the corners no less than twenty four inches (24").
Staff Comment: Compliance for this standard would be verified at the time of
building permit review.
15. Critical Areas: Project sites which contain critical areas are required to comply with the Critical Areas
Regulations (RMC 4-3-050). Based on City of Renton Critical Areas Maps, the site is located within the
Wellhead Protection Area (Zone 2). According to the submitted geotechnical report, geological
hazardous areas are not present on the subject site. The proposal is consistent with the Critical Areas
Regulations.
Geologically Hazardous Areas: Based upon the results of a geotechnical report and/or
independent review, conditions of approval for developments may include buffers
and/or setbacks from buffers. A standard 15-foot building setback is required for all
structures from Protected Slope areas. A 50-foot buffer and 15-foot building setback
are required from Very High Landslide Hazard Areas.
Staff Comment: City Records do not indicate the presence of any geological hazardous
areas on the project site. A geotechnical report prepared by Nelson Geotechnical
Associates, Inc (dated October 17, 2016) was submitted with the project application.
The site topography descends relatively gently from the east to the west with an
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 11 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
estimated total elevation change of approximately ten (10) feet across the site. The
steepest slope identified by the applicant was approximately 15 percent.
The applicant indicates that the estimated quantities for structural fill onsite would be
approximately 5 cubic yards of cut and 130 cubic yards of fill. This grading would be
required for the construction of the required plat improvements and new single family
residences. Temporary erosion and sedimentation control measures would be
implemented during construction including, but not limited to, Best Management
Practices (BMPs) such as site preparation and grading during the drier summer and
early fall months, installing siltation control fencing around the work areas, and
establishing a quarry spall construction entrance in accordance with City of Renton
requirements.
On October 4, 2016, a total of four test pits and two infiltration test pits were excavated
to depths ranging from 3 to 10 feet across the project site with a mini trackhoe. Grass
and surficial topsoil was encountered within the upper 1.5 feet, on top of medium dense
sand and fine to medium sand with gravel to a depth of approximately 8 to 9.5 feet
below the existing ground surface. Groundwater seepage was not encountered in any
of the test pits.
Staff recommends as a condition of approval that the applicant comply with the
recommendations included in the Geotechnical Engineering Study.
Wellhead Protection Area: City Records indicate that the project site is located entirely
within a Wellhead Protection Area Zone (Zone 2). All proposals for new facilities within
any zone of an aquifer protection area must be reviewed for compliance with this RMC
4-3-050 prior to issuance of any development permits for uses in which hazardous
materials are stored, handled, treated, used or produced or which increase the quantity
of hazardous materials stored, handled, treated, used, or produced. All fill material
regarding quality of fill and fill material source statement requirements, within aquifer
protection areas, are required per RMC 4-3-050G.8.i.
16. Compliance with Subdivision Regulations: RMC 4-7 provides review criteria for subdivisions. The
proposal is consistent with the following subdivision regulations if all conditions of approval are complied
with:
Compliance Subdivision Regulations and Analysis
Compliant
if
conditions
of approval
are met
Access: Each lot must have access to a public street or road. Access may be by a shared
driveway per the requirements of the street standards.
The maximum width of single loaded garage driveways shall not exceed nine feet (9') and
double loaded garage driveways shall not exceed sixteen feet (16').
Staff Comment: Along the south property line, the applicant is proposing a 20-ft wide by
120.036 ft long (2,187 sf) shared driveway tract with a 20-foot wide paved driveway to
served Lots 1 and 2 from Aberdeen Ave NE. RMC 4-6-060J.1 expressly provides as follows:
When Permitted: Shared driveways may be allowed for access to four (4) or fewer
residential lots, provided: a. At least one of the four (4) lots abuts a public right-of-way
with at least fifty (50) linear feet of property. As proposed, Lot 1 has ROW frontage of
44.01 feet along Aberdeen Ave NE and therefore does not meet the first condition in the
Shared Driveway Standards as outlined in RMC 4-6-060J. In addition, the proposed
driveway tract does not include an 8-foot landscaped area along the property line with
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 12 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
the adjacent neighbor, as required by CI-97 Shared Driveway Landscape Requirements.
The applicant submitted a Modification request in order to allow for a reduction in the
required ROW frontage of Lot 1 and the removal of the landscaped area. The modification
is supported by staff, if certain conditions are met (FOF 19). Furthermore, under RMC 4-
6-060J.1.d When Permitted: The shared driveway would not adversely affect future
circulation to neighboring properties. The proposed shared driveway would be located in
the same location as the existing driveway. Therefore, Staff has determined that the new
shared driveway will not change the impact on circulation in the neighborhood.
The project includes 64.01 feet of frontage along Aberdeen Ave NE. Half-street frontage
improvements required along the Aberdeen Ave NE includes, but is not limited
maintenance of the existing roadway and installation of 0.5 foot curb and gutter, 8-foot
planting strip, 5-foot sidewalk. The applicant has proposed paying a fee-in-lieu of
completing half-street frontage improvements along Aberdeen Ave NE.
Driveways shall be designed in accordance with Modified City Standard Plans 104.3 (RMC
4-4-080).
In order to meet the definition of a shared driveway and to ensure that additional curb
cuts are not need, staff recommends as a condition of the approval that Lot 1 take access
from the shared driveway tract and record the condition on the face of plat.
N/A Blocks: Blocks shall be deep enough to allow two tiers of lots.
Staff Comment: No blocks are proposed.
Lots: The size, shape, orientation, and arrangement of the proposed lots comply with the
requirements of the Subdivision Regulations and the Development Standards of the R-8
zone and allow for reasonable infill of developable land. All of the proposed lots meet
the requirements for minimum lot size, depth, and width.
Staff Comment: As discussed above under FOF 13 all lots meet the minimum lot
dimensional requirements in the R-8 zone after applying lot dimension averaging as
allowed by RMC 4-2-110D.31. The proposed lots are rectangular in shape. The
orientations of the lots have their front yards facing east towards Aberdeen Ave NE. The
proposed single-family residences would access to Aberdeen Ave NE via the paved shared
driveway. The building design of the new residence would be reviewed and approved at
the time of building permit application.
Compliant
if condition
of approval
is met
Streets: The proposed street system shall extend and create connections between
existing streets per the Street Standards outlined in RMC 4-6-060 Street Standards.
Staff Comment: The proposed project provides access to Aberdeen Ave NE (a Collector
Arterial Street) and Tract A (shared driveway). Existing right-of-way (ROW) width is
approximately 60 feet. To meet the City’s complete street standards for Collector Arterial
Streets, a minimum right of way width of 83 feet is required. Dedication of 11.5 feet of
right of way would be required along the project frontage. A street modification request
dated February 23, 2017 was received by the applicant. The modification requests to
maintain the existing paved roadway width and install a 0.5’ curb, 8’ planter, 5’ sidewalk,
and 0.5’ clear at the back of sidewalk along the project’s Aberdeen Avenue NE frontage.
Right of way width along the frontage would remain the same. The street modification
has been reviewed by City staff and is recommended for approval. Please see the Street
Modification Criteria and Analysis in FOF 18 for a complete summary of the request, staff
analysis, and staff recommendation.
As part of a modification request submitted by the applicant, City Development
Engineering staff is in support of a fee-in-lieu of construction of the frontage
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 13 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
improvements as there are no existing frontage improvements in the project vicinity. The
fee-in-lieu would be assessed at $101.00 per linear foot of frontage and would be
collected at the time of construction permit application.
Payment of the transportation impact fee is applicable on the construction of the single
family houses at the time of application for the building permit. The current rate of
transportation impact fee is $5,430.00 per new single family house. Fees are subject to
change. The transportation impact fee that is current at the time of building permit
application would be levied.
Relationship to Existing Uses: The proposed project is compatible with existing
surrounding uses.
Staff Comment: The proposed short plat is surrounded by existing detached single family
residences to the east, west, north and south of the site. In addition, R-8 zoning is also
located on Aberdeen Ave NE between SR 900 and NE 28th St (a distance of approximately
one (1) mile). The proposal would be compatible with the existing uses. The proposed lots
are similar in size and shape to the existing surrounding development pattern in the area
and would be consistent with the Comprehensive Plan and Zoning Code, which
encourages residential infill development in the Residential Medium Density and R-8
Zoning designations.
17. Availability and Impact on Public Services:
Compliance Availability and Impact on Public Services Analysis
Police and Fire: Police and Fire Prevention staff indicates that sufficient resources exist
to furnish services to the proposed development; subject to the condition that the
applicant provides Code required improvements and fees. Current fire impact fees are
applicable at the rate of $718.56 per single family unit. This fee is paid at time of building
permit issuance. Fees are subject to change. The fire impact fee that is current at the
time of building permit application would be levied.
Schools: It is anticipated that the Renton School District can accommodate any additional
students generated by this proposal at the following schools: Kennydale Elementary
School (0.8 miles from the subject site, school bus transportation provided), McKnight
Middle School (0.5 miles from the subject site and within walk distance of school; no
school bus transportation provided), and Hazen High School (2.7 miles from the subject
site; school bus transportation provided).
RCW 58.17.110(2) provides that no subdivision be approved without making a written
finding of adequate provision made for safe walking conditions for students who walk to
and from school. While the middle school is designated to be located within a close
enough proximity of the subject site, future students to the elementary school and high
school would be transported to school via bus. According to the online Renton School
District bus routes WebQuery, the bus stop is located at the intersection of NE 18th St
and Aberdeen Ave NE. A wide shoulder exists along both sides of Aberdeen Ave NE to
the elementary and high school bus stop (no sidewalks along Aberdeen Ave NE). Wide
shoulders and a patchwork of 5-foot wide sidewalks are located between the site and
McKnight Middle School at 1200 Edmonds Ave NE. The safest route to the middle school
is south along Aberdeen Ave NE to NE 16th St, east on NE 16th St to Edmonds Ave NE,
south on Edmonds Ave NE to McKnight Middle School. The identified routes provide a
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 14 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
safe walking route from the proposed subdivision to the bus stop or the respective
schools.
A School Impact Fee would be collected on behalf of the Renton School District for the
new residence at the time of building permit issuance. The current Renton School District
fee for new single family dwelling is $6,432.00 per unit.
Parks: Although there would be no significant impacts to the City of Renton Park System
anticipated from the proposed project, a Park Impact Fee is required of all new
residential development. The current Park Impact Fee is $2,740.07 per new residence
and is payable at the time of building permit issuance. Fees are subject to change. The
park impact fee that is current at the time of building permit application would be levied.
Compliant
if condition
of approval
is met
Storm Water: An adequate drainage system shall be provided for the proper drainage of
all surface water.
Staff Comment: A Preliminary Technical Information Report (TIR), dated February 16,
2017, was prepared and submitted with the short plat application by CG Engineering.
(Exhibit 7). Based on the City of Renton’s flow control map, the site falls within the Flow
Control Duration Standard area matching Forested Site Conditions and is within the
May Creek Drainage Basin. No downstream flooding or erosion issues were identified in
the TIR. The development is subject to Direct Drainage Review in accordance with the
2017 Renton Surface Water Design Manual (RSWDM). All nine (9) core requirements
and the six special requirements are addressed in the TIR.
a. Per the TIR, the project is exempt from Core Requirement #3: Flow Control
Facilities, because there is less than a 0.15 cfs increase in the difference of the
developed 100-year peak flows and the sum of the historical (forested) 100-year peak
flows.
b. The project is proposing an infiltration trench under the shared driveway tract
to comply with Core Requirement #9: On-Site BMPs. The trench has been sized to fully
infiltrate all roof runoff from Lots 1 and 2 and all runoff from the shared driveway tract.
This meets the requirements for Core Requirement #9. The trench has an overflow that
connects to the public storm drainage system in Aberdeen Avenue NE.
c. The project is exempt from Core Requirement #8: Water Quality Facilities,
because less than 5,000 square feet of new plus replaced pollution generating
impervious surface (PGIS) is proposed. However, the project is proposing a Contech
Stormfilter system to treat the PGIS that will be infiltrated from the shared driveway
tract before infiltration into the soil. This meets the requirements found in Section 5.2.1
– General Requirements for Infiltration Facilities, Groundwater Protection.
A geotechnical report, dated October 17, 2016, completed by Nelson Geotechnical
Associates, Inc. for the site has been provided. The submitted report describes the site is
a Low Erosion Hazard area. Erosion control measures will need to be in place prior to
starting grading activities on the site. In-situ infiltration testing was completed at two
test pits, which returned an infiltration rate of 61 inches per hour and a design
infiltration rate of 7.35 inches per hour. Geotechnical recommendations presented
need to be addressed within the project construction plans.
Section 5.2.1 of the RSWDM requires that infiltration tests be performed at the
elevation of the bottom of the proposed infiltration facility. The original report stated
that the infiltration tests were performed at approximately two feet below the existing
grade (approximately 296 feet) which is several feet above the bottom of the proposed
facility. A supplemental geotechnical memorandum dated February 10, 2017
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 15 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
completed by Nelson Geotechnical Associates, Inc. was provided. The memorandum
states that several deeper test pit explorations up to 10’ below the ground surface were
completed throughout the property. All test pits performed within the site encountered
and were terminated within native glacial recessional outwash soils consisting of fine to
medium sand with gravel and silt. Test Pit 1 and Infiltration Pit 1 were located
immediately north of the proposed infiltration facility. Test Pit 1 terminated at an
elevation of approximately 288 feet which is approximately 5 feet below the bottom of
the proposed facility and Infiltration Pit 1 terminated at approximately 290 feet which is
approximately 3 feet below the bottom of the proposed facility. Though infiltration
testing was completed at an approximate elevation of 296 feet, the soils encountered
did not change at deeper depths and the memo concludes that the recommended long-
term design infiltration rate provided is valid at the bottom of the trench (elevation of
293 feet).
A surface water development fee (SDC) of $1,608.00 per new single family residence
would apply. The project proposes two new residences, with credit provided for existing
residence proposed for removal. Therefore, the estimated total fee is $1,608.00. Fees
are subject to change. This is subject to final design and payable at construction permit
issuance.
Water: Water service is provided by the City of Renton. The site is in the Highlands service
area in the 435 hydraulic pressure zone. There is an existing 16-inch City water main
located in Aberdeen Ave NE (Water plan no. WTR2702825) that can deliver a maximum
total flow capacity of 4,200 gallons per minute (gpm). The approximate static water
pressure is 59 psi at the elevation of 298 feet. The site is located within Zone 2 of an
Aquifer Protection Area.
There is an existing ¾ inch water service serving the existing home on Lot 1 that may be
reused. The water service line shall be capped at the meter as part of the demolition of
the existing home. The project proposes one 1-inch water service line and meter to Lot
2, while maintaining the existing ¾ inch meter to Lot 1 (Exhibit 7). A private utilities
easement shall be provided where the service line is located in the shared driveway tract.
The development is subject to applicable water system development charges and meter
installation fees based on the size of the water meters. The 2017 water system
development charge (SDC) for each proposed ¾ inch or 1-inch domestic water service is
$3,486.00 per meter. The total SDC fee due is $3,486.00 and is due at construction permit
issuance. Water service installation charges for each proposed 1-inch water service is
$2,850.00 per meter. This is payable at construction permit issuance.
The 2017 drop-in meter fee is $400.00 for a ¾ inch meter or $460.00 for a 1-inch meter.
This fee is payable at building permit issuance.
The fire flow requirement is 1,000 gallons per minute (gpm) for a home up to 3,600
square feet, or 1,500 gpm for a home exceeding 3,600 square feet. A minimum of one
fire hydrant is required within 300 feet of the proposed homes and two fire hydrants are
required if required fire flow goes up to 1,500 gpm. Adequate fire flow is provided by
the main in Aberdeen Avenue NE. The existing fire hydrant located at 1816 Aberdeen
Avenue NE can be counted towards the requirement for one primary hydrant.
Sanitary Sewer: Wastewater service is provided by the City of Renton. There is an
existing 8-inch concrete gravity wastewater main located in Aberdeen Ave NE (see City
plan no. WWP2702825). There is an existing PVC side sewer serving the existing home
on Lot 1.
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 16 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
The project proposes one new 6-inch PVC sewer service line connection to serve Lot 2
while maintaining the existing PVC sewer line to serve Lot 1. The sewer service line shall
be capped at the property line as part of the demolition of the existing home and may
be reused to serve Lot 1 when future development occurs on the lot.
The development is subject to applicable wastewater SDC based on the size of the new
domestic water to serve the project. The 2017 SDC fee for a ¾ inch or 1-inch meter is
$2,540.00 per meter. These charges are payable at the time of construction permit
issuance.
The development is located in the West Kennydale and Aberdeen Ave NE Special
Assessment Districts (SADs). The SAD fee for the West Kennydale SAD is $1,050.00 for
each additional lot. The Aberdeen Avenue NE SAD does not require any additional
connection fees. The total SAD fees due are $1,050.00. SAD fees are due at construction
permit issuance.
18. Street Modification Analysis:
The applicant is requesting an Administrative Modification from RMC 4-6-060F.2, Minimum Design
Standards for Public Streets and Alleys, to maintain the existing street section and ROW width along the
site’s Aberdeen Ave. The requested modification would remove the requirements for approximately 11.5
feet of dedication along the street frontage, 0.5 foot curb, 8 foot planter strip,8 foot sidewalk, and 5 foot
bike lanes. The proposal is compliant with the following modification criteria, pursuant to RMC 4-9-250D,
if all conditions of approval are met. Therefore, staff is recommending approval of the requested
modification as noted below:
RMC 4-9-060B.9, permits a fee-in-lieu of required street improvements for a short plat development can
be considered if the standards of this section are met. City staff is in support of a fee-in-lieu for the
Aberdeen Avenue NE frontage. The current fee-in-lieu is $101.00 per linear foot of frontage. Per the King
County Assessor’s Map, the site’s Aberdeen Avenue NE frontage is 64 linear feet. Thus the fee-in-lieu
amount would be $6,464.00 ($101.00 / LF x 64 LF).
Compliance Street Modification Criteria and Analysis
a. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and the
proposed modification is the minimum adjustment necessary to implement these
policies and objectives.
Staff Comment:
The Community Design Element has applicable policies listed under a section labeled
Promoting a Safe, Healthy, and Attractive Community. These policies address walkable
neighborhoods, safety, and shared uses. The intent of the policies are to promote new
development with walkable places that support grid and flexible grid street and pathway
patterns, and are visually attractive, safe, and healthy environments. The requested
street modification is consistent with both the Land Use Element and the Community
Design Element policies.
b. Will meet the objectives and safety, function, appearance, environmental
protection, and maintainability intended by the Code requirements, based upon
sound engineering judgment.
Staff Comment:
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 17 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
19. Modification Analysis: The applicant is requesting a modification from RMC 4-6-060.J.1(a) Shared
Driveway Standards in order to allow the width of the lot abutting the public right of way (Lot 1) to be
less than 50 linear feet. Due to site constraints and the required 20 foot wide driveway tract, the
applicant is proposing a frontage width of 44 linear feet. The proposal is compliant with the following
modification criteria, pursuant to RMC 4-9-250, if all conditions of approval are met. Therefore, staff is
recommending approval of the requested modification, subject to conditions as noted below:
Compliance Modification Criteria and Analysis
a. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and the
proposed modification is the minimum adjustment necessary to implement these
policies and objectives.
Staff Comment: See FOF 16, Comprehensive Plan Analysis.
b. Will meet the objectives and safety, function, appearance, environmental protection
and maintainability intended by the Code requirements, based upon sound
engineering judgment.
Staff Comment: The applicant contends the modification will not negatively impact the
safety, function, appearance, environmental protection and maintainability of the
project. The reduced width of the frontage would still allow for the efficient siting of a
single-family home, and the driveway tract will accommodate required traffic on the site,
including emergency vehicle access.
Staff concurs the proposed modification would meet the objectives of function and safety
intended by the code requirements, as the reduction in the frontage width of Lot 1 will
still allow for enough room to construct a single-family home. In addition, the driveway
tract will be located in the same location as the existing driveway and will not require a
The City’s Public Works Transportation section and Economic Development section
have reviewed Aberdeen Avenue NE and the surrounding area and have determined
that a modified collector arterial street section is more suitable for the portion of
Aberdeen Avenue NE adjacent to the site. The determination was based on the fact
that the roadway is directly adjacent to single family residences and there is
insufficient space between the existing right of way and existing homes to expand the
roadway section to meet the neighborhood collector arterial standards.
c. Will not be injurious to other property(ies) in the vicinity.
Staff Comment:
There are no identified adverse impacts to other properties from the requested
modification.
d. Conforms to the intent and purpose of the Code.
Staff Comment: See comments under criterion ‘b’.
e. Can be shown to be justified and required for the use and situation intended; and
Staff Comment: See comments under criterion ‘b’.
f. Will not create adverse impacts to other property(ies) in the vicinity.
Staff Comment: See comments under criterion ‘c’.
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 18 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
new curb cut. The safety of pedestrian and vehicular traffic will not be negatively
impacted by the reduction of frontage width, as the ingress and egress location will not
change from the current condition.
c. Will not be injurious to other property(ies) in the vicinity.
Staff Comment: The six (6) foot reduction in the minimum frontage will not negatively
impact surrounding properties. The frontage width reduction will be nearly imperceptible
to neighboring property owners, as the new driveway tract will be located in the same
area as the existing driveway and will not significantly decrease the buildable area of
proposed Lot 1.
d. Conforms to the intent and purpose of the Code.
Staff Comment: See comments under criterion ‘b’.
e. Can be shown to be justified and required for the use and situation intended; and
Staff Comment: See comments under criterion ‘b’.
f. Will not create adverse impacts to other property(ies) in the vicinity.
Staff Comment: See comments under criterion ‘c’.
20. Modification Analysis: The applicant is requesting a modification from Shared Driveway Standards in
RMC 4-6-060.J.1(a) and Shared Driveway Landscape Standards in CI-97 in order to allow the width of the
lot abutting the public right of way (Lot 1) to be less than 50 linear feet and to allow the removal of the
required landscaped area within the tract. The proposal is compliant with the following modification
criteria, pursuant to RMC 4-9-250, if all conditions of approval are met. Therefore, staff is recommending
approval of the requested modification, subject to conditions as noted below:
Compliance Shared Driveway Standards Modification Criteria and Analysis
a. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and the
proposed modification is the minimum adjustment necessary to implement these
policies and objectives.
Staff Comment: See FOF 16, Comprehensive Plan Analysis.
b. Will meet the objectives and safety, function, appearance, environmental protection
and maintainability intended by the Code requirements, based upon sound
engineering judgment.
Staff Comment: The reduced width of the lot (Lot 1) will not negatively impact the safety,
function, appearance, environmental protection and maintainability of the project. The
width reduction would still allow for the efficient siting of a single-family home, and will
allow the driveway tract to accommodate required traffic on the site, including
emergency vehicle access. In addition, the safety of pedestrian and vehicular traffic will
not be negatively impacted by the reduction of frontage width, as the ingress and egress
location will not change from the current condition.
The proposed removal of the landscaped area in the driveway tract would not meet the
objectives or appearance intended by CI-97. However, a reduction in the width of the
required landscaped area instead of a complete removal would be able to provide an
effective buffer between the driveway and the adjacent property, and thereby meeting
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 19 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
the intent of the code, while allowing the applicant to retain the originally proposed 20
foot wide driveway tract. The reduced landscape buffer would enhance pedestrian
safety, improve vision clearance, and provide screening and buffering from the
neighboring properties. The Renton Fire Authority (RFA) may grant a variance to allow
for fire access to be reduced to 16 feet in the driveway tract instead of 20 feet. The RFA
has indicated their support of a variance for the paved driveway width reduction if the
future single-family home on Lot 2 is sprinkled (Exhibit 13). Therefore, staff
recommends as a conditional of approval that the applicant obtain a variance from the
Renton Fire Authority to allow for a reduction in the driveway tract pavement width
from 20 feet to 16 feet and provide documentation of the approved variance to the
current planning project manager prior to construction permit issuance.
c. Will not be injurious to other property(ies) in the vicinity.
Staff Comment: The six (6) foot reduction in the minimum frontage will not negatively
impact surrounding properties. The frontage width reduction will be nearly imperceptible
to neighboring property owners, as the new driveway tract will be located in the same
area as the existing driveway and will not significantly decrease the buildable area of
proposed Lot 1.
The four (4) foot landscaped area width will not negatively impact surrounding properties
and will be an improvement compared to the existing site characteristics. The landscaped
area along the edge of the driveway will provide a natural buffer between the project site
and the adjacent property to the south which does not exist today.
d. Conforms to the intent and purpose of the Code.
Staff Comment: See comments under criterion ‘b’.
e. Can be shown to be justified and required for the use and situation intended; and
Staff Comment: See comments under criterion ‘b’.
f. Will not create adverse impacts to other property(ies) in the vicinity.
Staff Comment: See comments under criterion ‘c’.
I. CONCLUSIONS:
1. The subject site is located in the Residential Medium Density (RLD) Comprehensive Plan designation and
complies with the goals and policies established with this designation if all conditions of approval are
met, see FOF 12.
2. The subject site is located in the Residential-8 (R-8) zoning designation and complies with the zoning
and development standards established within this designation provided the applicant complies with
City Code and conditions of approval, see FOF 13.
3. The proposed short plat complies with the Residential Design and Open Space Standards provided the
applicant complies with City Code and conditions of approval, see FOF 14.
4. The subject site is located within the wellhead protection area zone (Zone 2). No other Critical Areas
are located on the project site, see FOF 15.
5. The proposed short plat complies with the subdivision regulations as established by City Code and state
law provided all advisory notes and conditions are complied with, see FOF 16.
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 20 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
6. The proposed short plat complies with the street standards as established by City Code and the
modification request supported by staff, provided the project complies with all advisory notes and
conditions of approval contained herein, see FOF 16 and 19.
7. The proposed short plat complies with the Shared Driveway Standards modification criteria for the
frontage width reduction and landscaped area reduction in the driveway tract if all conditions of
approval are met, see FOF 19.
8. There are safe walking routes to the schools and school bus stops, see FOF 17.
9. There are adequate public services and facilities to accommodate the proposed short plat, see FOF 17.
J. DECISION:
The Aberdeen Ave Short Plat, File No. LUA16-000967, SHPL-A, as depicted in Exhibit 2, is approved and is subject
to the following conditions:
1. The applicant shall obtain a demolition permit and complete a final inspection from the City for the
removal of the residence, garage, and shop located on the City for demolition of the existing residence
on Lots 1 and 2 in order to comply with Residential-8 (R-8) setbacks of the zone prior to short plat
recording.
2. The applicant shall submit a detailed landscape plan that complies with RMC 4-8-120D.12 at the time of
utility construction permit application to the Current Planning Project Manager for review and
approval. Landscaping shall be installed prior to final occupancy for each single family building permit.
3. The applicant shall submit a detailed landscape plan that complies with the minimum tree density
requirements of both lots at the time of utility construction permit application to the Current Planning
Project Manager for review and approval pursuant to RMC 4-4-1309.d prior to construction permit
issuance.
4. The applicant shall record a note on the face of the plat that executes a shared maintenance agreement
for equal ownership and maintenance responsibilities for improvements in Tract A. A draft version of a
shared maintenance agreement shall be submitted for review to the Current Planning Project Manager
prior to final short plat approval.
5. The applicant shall comply with the recommendations included in the Geotechnical Engineering Study
prepared by Nelson Geological Associates (dated October 17, 2016), or an updated report at a later
date.
6. The applicant shall provide access to Lot 1 from the shared driveway tract and shall record this
condition on the face of the short plat.
7. The applicant shall obtain a variance from the Renton Fire Authority to allow for a reduction in the
driveway tract pavement width from 20 feet to 16 feet and provide documentation of the approved
variance to the Current Planning Project Manager prior to construction permit issuance.
DATE OF DECISION ON LAND USE ACTION:
SIGNATURE:
Jennifer Henning, Planning Director Date
City of Renton Department of Community & Economic Development Administrative Report & Decision
ABERDEEN AVE SHORT PLAT LUA16-000967, SHPL-A
April 24, 2017 Page 21 of 21
Administrative Short Plat Report 16-000967 – Aberdeen Ave Short Plat
TRANSMITTED this 24th day of April, 2017 to the Owner/Applicant/Contact:
Owner/Applicant:
PMP Investors LLC
8638 138th Pl,
Newcastle, WA 98059
Contact:
Carmel Gregory,
CG Engineering
250 4th Ave S., Ste 200
Edmonds, WA 98020
TRANSMITTED this 24th day of April, 2017 to the Parties of Record:
N/A
TRANSMITTED this 24th day of April, 2017 to the following:
C.E. "Chip" Vincent, CED Administrator
Brianne Bannwarth, Development Engineering Manager
Lillian Watson, Property and Technical Services
Vanessa Dolbee, Current Planning Manager
Ann Fowler, Plan Review
Fire Marshal
K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION:
The administrative land use decision will become final if the decision is not appealed within 14 days of the
decision date.
APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing
Examiner on or before 5:00 PM on May 8, 2017. An appeal of the decision must be filed within the 14-day
appeal period (RCW 43.21.C.075(3); WAC 197-11-680), together with the required fee to the Hearing
Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057. RMC 4-8-110.B governs appeals to the
Hearing Examiner and additional information regarding the appeal process may be obtained from the City
Clerk’s Office, (425) 430-6510.
EXPIRATION: The administrative short plat decision will expire two (2) years from the date of decision. A single
one (1) year extension may be requested pursuant to RMC 4-7-070M.
RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened
by the approval body. The approval body may modify his decision if material evidence not readily discoverable
prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the
reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will
be no further extension of the appeal period. Any person wishing to take further action must file a formal
appeal within the 14-day appeal time frame.
THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications
may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals
to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing
through the Hearing Examiner. All communications are public record and this permits all interested parties to
know the contents of the communication and would allow them to openly rebut the evidence in writing. Any
violation of this doctrine could result in the invalidation of the appeal by the Court.