HomeMy WebLinkAbout17a - CarMax #7252 Proposed SignageNG2 PROTOTYPE SIGNAGE
RENTON, WA 98057
PROPOSED SIGN PACKAGE for
LOCATION #7252 @ 3751 EAST VALLEY ROAD
REV. DATE CHANGE
FEBRUARY 24, 2013
05-12-14
06-18-14 Revise graphics on sign type “I” to NG2 standard.
Update new code sheet, Sign A1 - show sq ft, Sign C - Change to blue perforated vinyl faces.
Sign E4, E5 and E7 - Delete, Sign E8 - Side B - Sales and service right arrows,
Sign E9- Note associated with pylon sign option , Sign F, G, H and I need to be updated to new font and
layout for NG2.
07-15-14 Update pages 2, 3, 13 and 14. Deleted page 7.
03-4-15 Update Site Plan to SP 13.
03-24-15 Update sign placement of Sign E6 & E8. Update arrow on Sign E4.
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
2CODE RESEARCH AND CHART
Summary:
SIGN TYPE ALLOWED PER CODE PROPOSED Sign Description Reason Surplus SF
Freestanding
(1) 5' OAH monument sign, 1.5 sq ft per linear
ft of frontage. NTE 300 sq ft and sq ft divided
between the two face. Max sq ft per face 150
sq ft. One sign per street frontage
A2- 200 sq ft monument 5' OAH
A1 Option - 300 sq ft , 5' OAH and
at 40' OAH
A2 - 200 sq ft monument 100 sq ft
faces 5' OAH.
A1 - 300 sq ft pylon 150 sq ft, 40'
OAH.
Monument sign A2 for traffic coming off of
highway 167. Max height allowed by code
along with sq ft. Sign will help direct
customers to the main entrance. A1 will
need to be determined if a variance is to be
obtained for more height to obtain visibility
to Hwy 167. Surrounding businesses do have
high rise signs
0
Wall Signs 20 % of building façade per elevation. Not
transferable to another elevation.
Standard per prototype along
with additional traditional wall
cabinet
(2) 55 sq ft illuminated channel
letters "CARMAX", (1)26.7 sq ft
illuminated channel letters
"Service", (1) 150 sq ft wall cabinet
on North elevation
Standard wall signage for prototype and an
additional cabinet along the north elevation
for max visibility
West 364 sq
East 309
South 1214.3
North 1078.
Directional's Subject to review by building inspector. Logos
are allowed Standard (6) 4' OAH, 4 sq ft As needed n/a
Lot Signs Not regulated, subject to review Prototype, as needed.
(2) DNE, Row Markers (TBD), (8)
Reserved and Appraisal post and
panel w/rubber base, (1pr)
Carwash, (1) Visitor, (2) Stop Change
Driver
Prototype.n/a
Banners (1) 100 sq ft banner hung on the building allowed
prior to the finalization of building permit.
**VARIANCE MAY BE REQUIRED FOR
STANDARD BANNERS**
#7252 Renton, WA
** Possible Variance**
Site is located off of Hwy 167 which has heavy traffic, heading South exit SW 43rd takes you to the corner of the site. Code restricts height allowance but, surrounding businesses do
have hi rise signs visible to the highway. Variance should be considered here to obtain better visibility to the highway. Code will allow for a large amount of square footage on wall
signs, all standard signs will be allowed with leftover square footage.
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
SITE PLAN with SIGN SCHEDULE
A1
A1
C
D
I
E1
E2
E3
E3
E3
E3
E3
E3E3
E3
E4
E6
E8
E8
E4E9
K
L
H
F
G
A2
A2
B
B1
B2
SERVICE CHANNEL LETTERS-CL26
150 S.F. CHANNEL LETTERS WALL SIGN
D/F DIRECTIONAL SIGN
D/F DIRECTIONAL SIGN
D/F DIRECTIONAL SIGN
D/F DIRECTIONAL SIGN
S/F DIRECTIONAL SIGN
S/F DIRECTIONAL SIGN
S/F DIRECTIONAL SIGN
DO NOT ENTER SIGN (2)
ROW MARKERS (TBD)
ESCORT SIGN (NOT SHOWN)
CAR WASH ENTER/EXIT SIGNS
STOP CHANGE DRIVERS SIGN (2)
RESERVED SIGN (MOVEABLE)
APPRAISALS (MOVEABLE)
L E G E N D
LIGHTED PYLON SIGN
INDIVIDUAL CHANNEL LETTERS -CL55 (2)
LIGHTED ENTRANCE MONUMENT SIGN
INDICATES SINGLE ROW PANEL MOUNTED TO POST SUPPLIED BY FH
INDICATES SINGLE ROW PANEL MOUNTED TO EXISTING LIGHT POST
INDICATES DOUBLE ROW PANELS MOUNTED TO EXISTING LIGHT POST
J
3
SP-13
J
J
F
F
E1
D
E2E3E6
C
I
E3E9
Future Sign
Future Sign
H
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
AERIAL OVERLAY with PHOTO REFERENCES 4
5 700 FEET
200 FEET
1
3
500 FEET
250 FEET
2 400 FEET
6 350 FEET
4
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
PHOTO SURVEY STUDY with NUMBERS for REFERENCE 5
entrance
LOOKING NORTH ON EAST VALLEY ROAD
LOOKING EAST ON SW 41ST STREET LOOKING NORTH ON 167 LOOKING SOUTH ON 167
LOOKING SOUTH ON EAST VALLEY ROAD LOOKING WEST ON SW 41ST STREET
4 5 6
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
DOUBLE FACED PYLON SIGNS 6
FABRICATED ALUMINUM CABINET W/
CARMAX SATIN BLUE FINISH.
ACRYLIC FACE ALUMINUM CHANNEL LETTERS/DASHES.
CAR/DASHES HAVING YELLOW FACES/YELLOW RETURNS & TRIM CAP
MAX HAVING WHITE FACES/WHITE RETURNS & TRIM CAP
INTERNAL WHITE LED LIGHTING IN LETTERS/DASHES.
GRAPHICS AND COPY:
“CAR & DASHES” - YELLOW #2037
“MAX- #2447 WHITE
LETTER RETURNS - SATIN FINISH WHITE
LETTER RETURNS - YELLOW PMS-109 SATIN FINISH
CABINET CARMAX PMS-281 SATIN BLUE FINISH
SQ. TUBE STEEL SUPPORT TO BE PER FH ENGINEERING REQUIREMENTS
w/ MATTHEWS BRUSHED ALUMINUM FINISH ON ALUMINUM POLE COVERS.
277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP
TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER
SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS.
DEDICATED CIRCUITS
ALL BRANCH CIRCUITS SHALL BE DEDICATED TO
SIGNS(INCLUDING GROUND AND NEUTRAL) AND
SHALL NOT BE SHARED WITH OTHER LOADS
Number of 277v - 20 Amp Circuits Req’d TBD
DOUBLE-FACED PYLON SIGN ELEVATION END VIEW
SCALE: 3/16” = 1’-0”
PAINTED FINISH
A1SIGN TYPE STANDARD INSTALL IS TO BE DIRECT PIPE EMBEDMENT
INTO CONCRETE FOOTING PER FH ENGINEERING SPECS.
MASONRY BASE TO MATCH
BLDG MATERIALS BY GC
(ALL CABINETS TO HAVE COUNTER-SUNK SCREWS
AND FACES TO HAVE BUTT SEAMS)
(ALL PYLON COVERS TO HAVE BUTT SEAMS)40'-0"23'-3"
1'-4 1/2"
26’-0”6'-3"2’-11”8"5"5"3’-2”
2'-4"
FLAGGING REQUIRED TO DETERMINE APPROPRIATE HEIGHT
3’-0”145.31 SQ.FT
145.31 SQ.FT
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
DOUBLE FACED MONUMENT/ENTRY SIGN 7
SIDE A
FABRICATED ALUMINUM CABINET W/
CARMAX BLUE FINISH.
ACRYLIC FACE ALUMINUM CHANNEL LETTERS/DASHES.
HAVING YELLOW FACES/YELLOW RETURNS & TRIM CAPCAR/DASHES
HAVING WHITE FACES/WHITE RETURNS & TRIM CAPMAX
INTERNAL WHITE LED LIGHTING IN LETTERS/DASHES.
GRAPHICS AND COPY:
“CAR & DASHES” - YELLOW #2037
“MAX- #2447 WHITE
LETTER RETURNS - SATIN FINISH WHITE
LETTER RETURNS - YELLOW PMS-10 SATIN FINISH 9
CABINET - CARMAX BLUE PMS-281 FINISH SATIN
ENTRANCE CABINET - CARMAX WHITE FINISH
PAINTED FINISH
WHITE ALUMINUM CABINET W/ ROUTED COPY
BACKED WITH #4774 WHITE ACRYLIC
HAVING BLUE PERF. VINYL APPLIED TO FIRST SURFACE.
INTERNAL H.O. FLUORESCENT LIGHTING.
MASONRY BASE TO MATCH
BLDG MATERIALS BY GC
DOUBLE FACE LIGHTED MONUMENT SIGN ELEVATION (1) REQ’D END VIEW
SIDE B
RECT. SUPPORT COVER WITH MATTHEWS BRUSHED ALUMINUM FINISH
34.4 SQ. FT.
277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP
TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER
SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS.
DEDICATED CIRCUITS
ALL BRANCH CIRCUITS SHALL BE DEDICATED TO
SIGNS(INCLUDING GROUND AND NEUTRAL) AND
SHALL NOT BE SHARED WITH OTHER LOADS
Number of v - 20 Amp Circuits Req’d TBD 277
STANDARD INSTALL IS TO BE DIRECT PIPE EMBEDMENT
INTO CONCRETE FOOTING PER FH ENGINEERING SPECS.
SCALE: ½”= 1’-0”
A2SIGN TYPE
(ALL CABINETS TO HAVE COUNTER-SUNK SCREWS
AND FACES TO HAVE BUTT SEAMS)
(IF ALUM. COVER REQ'D, BUTT SEAMS TO BE USED)5'-0"entrance
entrance
9'-3"1’-0”3 1/4"3’-8 3/4”9 1/2"5 1/2"9’-9 1/2”1’-2”3”1’-10”
1’-4”
5"5"
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
INDIVIDUAL ILLUMINATED CHANNEL LETTERS (TWO REQ’D)CM-CL55
INDIVIDUAL LED ILLUMINATED CHANNEL LETTERS (ONE SET REQ’D)
26.7 SQ. FT.
26.7 SQ. FT.
55.0 SQ. FT.
CM-S-CL26
NEXT GEN 2 EXTERIOR WALL SIGNS
scale 3/8"=1'-0"
scale 1/2"=1'-0"
GRAPHICS AND COPY:
“CAR & DASHES” - YELLOW #2037 ACRYLIC FACES- CARMAX SATIN PMS-109 YELLOW RETURNS - YELLOW TRIM CAP
“MAX” - WHITE #2447 ACRYLIC FACES - SATIN WHITE RETURNS - WHITE TRIM CAP
BLUE ACM BACKGROUND BY CARMAX G.C.
277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP
TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER
SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS.
DEDICATED CIRCUITS
ALL BRANCH CIRCUITS SHALL BE DEDICATED TO
SIGNS(INCLUDING GROUND AND NEUTRAL) AND
SHALL NOT BE SHARED WITH OTHER LOADS
Number of 277v - 20 Amp Circuits Req’d TBD
8
BSIGN TYPE
CSIGN TYPE
Custom Wireway Behind Wall
No Penetrations within 4” of Seam
Hinge required to allow back to swing open
WIREWAY BEHIND WALL
¼" Ø Stainless Steel
5 7/8"
55 SQ. FT
BLUE ACM WALL PANELS
BY GC
4"4"NO PENETRATIONS
IN THIS AREA
WIREWAY BEHIND WALL
16'-8" WALL PANEL
16'-6 1/2"2'-6"3'-3 1/2"2'-2 1/2"1'-8"10'-4 "2’-7 1/8”GRIP-GARD SATIN FINISH CARMAX BLUE (PMS-281) RETURNS
LETTER COLORS
PMS-281 BLUE DAY/NIGHT PERF. VINYL FACE OVERLAY
CLEAR ACRYLIC FACES/SECOND SURFACE WHITE DIFFUSER W/ BLUE TRIM CAP
w/ Vinyl Overlay
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
ELEVATIONBSIGN TYPE
CONCEALED WIREWAY SPECIFICATIONS:
Ÿ 4” deep (additional blocking by GC will be shown on architectural detail for supporting wire way)
Ÿ Wiring for the letters may be drilled straight through the sign band into the wire way.
Ÿ Power supplies to be mounted inside the same wire way.
Ÿ The wire way will have a door on the back that opens (swings up) to expose all of the wiring and power supplies
allowing for easy installation and service.
Ÿ The wire way will be painted blue to match (the adjacent ACM)
‘Dash’ Section
on Wireway
8"
‘C’ Section
On Wireway
PLACEMENT OF SIGNS
ON SIGN BAND
3'-6 7/8"4'-6 7/8"9
14’-2” RACEWAY
3’-4”OF JOINT
7 1/4”
ACM SIGN BAND
J-Box Inside Wireway
TOP OF SIGN BAND
BOTTOM OF SIGN BAND
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
S/F ILLUMINATED CHANNEL LETTER WALL SIGN
SCALE: 3/8” = 1’-0” 150 SQ. FT.
6"5"
277V ELECTRICAL REQ’D
TYPICAL SECTION
277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP
TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER
SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS.
DEDICATED CIRCUITS
ALL BRANCH CIRCUITS SHALL BE DEDICATED TO
SIGNS(INCLUDING GROUND AND NEUTRAL) AND
SHALL NOT BE SHARED WITH OTHER LOADS
Number of 277v - 20 Amp Circuits Req’d TBD
CM-WS-CL 150
FABRICATED ALUMINUM CABINET
WITH .125” ALUMINUM FACE -
FILLER PAINTED CARMAX BLUE
FACE PAINTED CARMAX BLUE
(ALL CABINETS TO HAVE BUTT SEAMS & COUNTER-SUNK SCREWS)
INDIVIDUAL ALUMINUM CHANNEL LETTERS
WITH ACRYLIC FACES, TRIM CAP RETAINERS
AND SLOAN WHITE LED LIGHTING.
ATTACH LETTER CHANNELS TO BACKGROUND WITH
#10 TEK SCREWS.
WEEP HOLES REQ’D IN BOTTOM OF LETTERS
120V-277V/12VDC SLOAN LED POWER SUPPLIES TO BE HOUSED
IN BACKGROUND CABINET.
CUT OFF SWITCH TO BE LOCATED END OF CABINET.
GRAPHICS AND COPY:
“CAR & DASHES” - YELLOW #2037 ACRYLIC FACES- CARMAX SATIN PMS-109 YELLOW RETURNS - YELLOW TRIM CAP
“MAX” - WHITE #2447 ACRYLIC FACES - SATIN WHITE RETURNS - WHITE TRIM CAP
PMS-291 SATIN BLUE BACKGROUND
23'-3"6'-3"2’-11”8"DSIGN TYPE
10
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
11NEXT GEN 2 EXTERIOR ELEVATIONS
16'-8"
16'-6 1/2"
16'-8"
16'-6 1/2"
23'-3"D
C26.7 SQ. FT. SIGN
55 SQ. FT. SIGN
55 SQ. FT. SIGN
B
B
150 S.F. SIGN
80’-5 1/2”
280'-6"
tupelo
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
LOT DIRECTIONALS (non-illuminated)
REFLECTIVE WHITE VINYL ARROWS
3M-680-10 FIRST SURFACE APPLIED.
REFLECTIVE YELLOW VINYL COPY
3M-680-71 FIRST SURFACE APPLIED
(COPY ON TWO FACES)
ALUMINUM CABINET W/ CARMAX SATIN BLUE FIN.
PAINTED BRUSHED ALUMINUM FINISH ON
RECTANGULAR SUPPORT FRAME
2”
1 1/2”1 1/2”
OPEN
END VIEW
10”2 1/4"2 3/8"carrow
SIDE A SIDE B
4'-0 "1'-4 3/4 "2'-10"
3'-2"
LOT DIRECTIONAL
scale 3/4"=1'-0"
E1SIGN TYPE
FOUR SQ. FT.(2) 1'-6"ø x 2'-6" DEEP
CONC. FOOTING
NOTE:
ALUMINUM EMBEDDED IN
CONC. MUST BE HAVE MOISTURE
BARRIER COATING TO PREVENT CORROSION
(2" X 10" X .125" RECT. TUBE)
REFLECTIVE VINYL #3M-680-71 YELLOW
REFLECTIVE VINYL #3M-680-10 WHITE
CARMAX PMS-281 BLUE SATIN FIN.
MATTHEWS BRUSHED ALUMINUM FIN.
OPEN
LOT DIRECTIONAL
scale 3/4"=1'-0"
E4SIGN TYPE
SIDE A SIDE B
12
OPEN
LOT DIRECTIONAL
scale 3/4"=1'-0"
E2SIGN TYPE
SIDE A
SIDE B BLANK
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
LOT DIRECTIONALS (non-illuminated)
REFLECTIVE WHITE VINYL ARROWS
3M-680-10 FIRST SURFACE APPLIED.
REFLECTIVE YELLOW VINYL COPY
3M-680-71 FIRST SURFACE APPLIED
(COPY ON TWO FACES)
ALUMINUM CABINET W/ CARMAX SATIN BLUE FIN.
PAINTED BRUSHED ALUMINUM FINISH ON
RECTANGULAR SUPPORT FRAME
2”
1 1/2”1 1/2”
OPEN
OPEN
OPEN
LOT DIRECTIONAL LOT DIRECTIONAL
scale 3/4"=1'-0"
END VIEW
E8SIGN TYPE E9SIGN TYPE
10”2 1/4"2 3/8"carrow
SIDE A
SIDE A
SIDE A
SIDE B
SIDE B 4'-0 "1'-4 3/4 "2'-10"
3'-2"
LOT DIRECTIONAL
scale 3/4"=1'-0"
E6SIGN TYPE
FOUR SQ. FT.(2) 1'-6"ø x 2'-6" DEEP
CONC. FOOTING
NOTE:
ALUMINUM EMBEDDED IN
CONC. MUST BE HAVE MOISTURE
BARRIER COATING TO PREVENT CORROSION
(2" X 10" X .125" RECT. TUBE)
REFLECTIVE VINYL #3M-680-71 YELLOW
REFLECTIVE VINYL #3M-680-10 WHITE
CARMAX PMS-281 BLUE SATIN FIN.
MATTHEWS BRUSHED ALUMINUM FIN.
entrance entrance
13
SIDE B
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
2"
DOUBLE FACE ROW MARKER SIGN PANELSCM-D-RM
scale 3/4"=1'-0"
14
G
2'-6 "2'-6"6'-0".FLAT 125” ALUMINUM PANEL
WITH PAINTED PMS-032 RED FINISH
ON ALL SURFACES.
REFLECTIVE WHITE 3M-680-10
VINYL ON COPY AND BORDER
(ONE SIDE ONLY)½”8” X 8” X ¼” ALUMINUM PLATE
MOUNTED INTO CONCRETE
WITH MASONRY ANCHORS.
PAINT MATTHEWS 13B-2T GRAY
SINGLE FACE SIGN ELEVATION | TWO (2)CM-D-SCD
scale 1/2"=1'-0"
J
2” X 2” X 3/16" SQUARE
TUBE (6061-T6) PAINTED
MATTHEWS 13B-2T
GRAY
OPERATIONAL SIGNS (non-illuminated)
SINGLE FACE SIGN ELEVATIONCM-D-ESCORTH
REFLECTIVE VINYL #3M-680-71 YELLOW
REFLECTIVE VINYL #3M-680-10 WHITE
CARMAX PMS-281 BLUE SATIN FIN.
REFLECTIVE VINYL #3M 680-72 RED
MATTHEWS FIN.13B-2T GRAY
2 3/4"2'-6 "2'-6 "10"STANDARD HIGHWAY
SIGN PANEL
(SETON 29594)
.125” ALUMINUM
SIGN PANEL
PAINTED CARMAX BLUE
ON ALL SURFACES.
WHITE 3M 680-10 & 3M 680-17
YELLOW REFLECTIVE
VINYL COPY
SINGLE FACE “DO NOT ENTER” SIGN | TWO (2)
2” X 2” X 3/16" SQUARE
TUBE (6061-T6) PAINTED
MATTHEWS 13B-2T
2'-0 "
CM-D-DNE
scale 1/2"=1'-0"
F6'-0"2’-0”
FLAT .125” ALUMINUM PANEL PAINTED CARMAX BLUE
3M 680-10 WHITE REFLECTIVE COPY & 3M 380-71 YELLOW
HIGHLIGHTED COPY.10"1 1/4"¾"1 3/4"PLATE MOUNTED
TO CONCRETE SURFACE
GRAY
EXISTING LIGHT POLE
.125” ALUMINUM PANEL
WITH 1 ½” LEG FOR ATTACHMENT
TO SUPPORT . PANEL PAINTED CARMAX
BLUE BACKGROUND.
COPY TO BE WHITE REFLECTIVE VINYL
3M-680-10.
MOUNT TO PIPE WITH STAINLESS STEEL STRAP
1'-0 "1'-0 "10 "ROW MARKER
1'-0"
1 1/2"
SPECIFICATIONS:FABRICATED .125" ALUMINUM PANELWITH 1 1/2" LEG FOR ATTACHMENT TOSUPPORT. PANEL TOBE PAINTED CARMAX BLUE.FIRST SURFACE COPY REFLECTIVEWHITE VINYL 3M 680-10.MOUNT TO 2" ALUMINUM SQ. TUBEPOSTS WITH 3/16" POP RIVET OR
MOUNT TO LIGHT POLE WITHMETAL STRAP.
EACH PANEL TO HAVETWO HOLES FOR POP RIVET MOUNTAND TWO 1” SLOTS FORSTRAP MOUNTING8’-0” ABOVE GRADE(SEE ROW MARKER DETAIL PAGE
FOR EXACT MARKERS REQUIRED)
A
3 SQ. FT.3 SQ. FT.
18 "18 "24 "CM-D-CW CM-D-CWE
ALL SIGNS ARE TO BE MOUNTED FLUSH TO WALL AT ENTRANCE/EXIT LANES
ON CAR WASH BUILDING - 4’-0” ABOVE GRADE
FLAT .125” ALUMINUM PANEL W/ CARMAX BLUE BACKGROUND
“STOP SIGN/DO NOT ENTER”- RED 3M-680-72 W/ COPY TO BE WHITE 3M-680-10
WALL PANEL WALL PANEL scale 1"=1'-0"scale 1"=1'-0"I1 I29 3/4"12"1"2"MAIN COPY TO BE 3M 680-10 WHITE
MATT SMITH
JESSICA VIDAL
J. CARPENTER
15
LOCATION #7252
3751 EAST VALLEY ROAD
RENTON, WA 98057
23-23170-10-R5
23-23170-10
FEBRUARY 24, 2014
R1-05-12-14 VA/JK Revise as per pdf mark up attached.
R2-06-18-14 BW Revise graphics on sign I.
R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page
R4 03.4.15 VA/JDR Update Site plan to SP 13
R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8,
Update arrow of Sign E4.
NEXT GEN RESERVED (non-illuminated)
LSIGN TYPEKSIGN TYPE
.125” ALUMINUM PANEL WITH
SCREENED LT. BLUE/DK. BLUE
GRADATION ON FACE-SOLID
BLUE ON BACKSIDE & EDGES.
WHITE REFLECTIVE COPY
.125” ALUMINUM PANEL WITH
SCREENED YELLOW/ORANGE
GRADATION ON FACE W/ ORANGE
BACKSIDE & EDGES
3M 680-75 BLUE REFLECTIVE COPY
1'-2"1'-2"5’-0”5’-0”S/F SIGN PANEL WITH MOVEABLE BASE (LEED CERTIFIED) / FIVE (5) REQ’D S/F SIGN PANEL WITH MOVEABLE BASE (LEED CERTIFIED) / THREE (3) REQ’D
SCALE: 3/4” = 1’-0”SCALE:3/4” = 1’-0”1'-8 "1'-8 "ROUNDED CORNERS (1" RADIUS)ROUNDED CORNERS (1" RADIUS)
15