Loading...
HomeMy WebLinkAbout17a - CarMax #7252 Proposed SignageNG2 PROTOTYPE SIGNAGE RENTON, WA 98057 PROPOSED SIGN PACKAGE for LOCATION #7252 @ 3751 EAST VALLEY ROAD REV. DATE CHANGE FEBRUARY 24, 2013 05-12-14 06-18-14 Revise graphics on sign type “I” to NG2 standard. Update new code sheet, Sign A1 - show sq ft, Sign C - Change to blue perforated vinyl faces. Sign E4, E5 and E7 - Delete, Sign E8 - Side B - Sales and service right arrows, Sign E9- Note associated with pylon sign option , Sign F, G, H and I need to be updated to new font and layout for NG2. 07-15-14 Update pages 2, 3, 13 and 14. Deleted page 7. 03-4-15 Update Site Plan to SP 13. 03-24-15 Update sign placement of Sign E6 & E8. Update arrow on Sign E4. MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. 2CODE RESEARCH AND CHART Summary: SIGN TYPE ALLOWED PER CODE PROPOSED Sign Description Reason Surplus SF Freestanding (1) 5' OAH monument sign, 1.5 sq ft per linear ft of frontage. NTE 300 sq ft and sq ft divided between the two face. Max sq ft per face 150 sq ft. One sign per street frontage A2- 200 sq ft monument 5' OAH A1 Option - 300 sq ft , 5' OAH and at 40' OAH A2 - 200 sq ft monument 100 sq ft faces 5' OAH. A1 - 300 sq ft pylon 150 sq ft, 40' OAH. Monument sign A2 for traffic coming off of highway 167. Max height allowed by code along with sq ft. Sign will help direct customers to the main entrance. A1 will need to be determined if a variance is to be obtained for more height to obtain visibility to Hwy 167. Surrounding businesses do have high rise signs 0 Wall Signs 20 % of building façade per elevation. Not transferable to another elevation. Standard per prototype along with additional traditional wall cabinet (2) 55 sq ft illuminated channel letters "CARMAX", (1)26.7 sq ft illuminated channel letters "Service", (1) 150 sq ft wall cabinet on North elevation Standard wall signage for prototype and an additional cabinet along the north elevation for max visibility West 364 sq East 309 South 1214.3 North 1078. Directional's Subject to review by building inspector. Logos are allowed Standard (6) 4' OAH, 4 sq ft As needed n/a Lot Signs Not regulated, subject to review Prototype, as needed. (2) DNE, Row Markers (TBD), (8) Reserved and Appraisal post and panel w/rubber base, (1pr) Carwash, (1) Visitor, (2) Stop Change Driver Prototype.n/a Banners (1) 100 sq ft banner hung on the building allowed prior to the finalization of building permit. **VARIANCE MAY BE REQUIRED FOR STANDARD BANNERS** #7252 Renton, WA ** Possible Variance** Site is located off of Hwy 167 which has heavy traffic, heading South exit SW 43rd takes you to the corner of the site. Code restricts height allowance but, surrounding businesses do have hi rise signs visible to the highway. Variance should be considered here to obtain better visibility to the highway. Code will allow for a large amount of square footage on wall signs, all standard signs will be allowed with leftover square footage. MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. SITE PLAN with SIGN SCHEDULE A1 A1 C D I E1 E2 E3 E3 E3 E3 E3 E3E3 E3 E4 E6 E8 E8 E4E9 K L H F G A2 A2 B B1 B2 SERVICE CHANNEL LETTERS-CL26 150 S.F. CHANNEL LETTERS WALL SIGN D/F DIRECTIONAL SIGN D/F DIRECTIONAL SIGN D/F DIRECTIONAL SIGN D/F DIRECTIONAL SIGN S/F DIRECTIONAL SIGN S/F DIRECTIONAL SIGN S/F DIRECTIONAL SIGN DO NOT ENTER SIGN (2) ROW MARKERS (TBD) ESCORT SIGN (NOT SHOWN) CAR WASH ENTER/EXIT SIGNS STOP CHANGE DRIVERS SIGN (2) RESERVED SIGN (MOVEABLE) APPRAISALS (MOVEABLE) L E G E N D LIGHTED PYLON SIGN INDIVIDUAL CHANNEL LETTERS -CL55 (2) LIGHTED ENTRANCE MONUMENT SIGN INDICATES SINGLE ROW PANEL MOUNTED TO POST SUPPLIED BY FH INDICATES SINGLE ROW PANEL MOUNTED TO EXISTING LIGHT POST INDICATES DOUBLE ROW PANELS MOUNTED TO EXISTING LIGHT POST J 3 SP-13 J J F F E1 D E2E3E6 C I E3E9 Future Sign Future Sign H MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. AERIAL OVERLAY with PHOTO REFERENCES 4 5 700 FEET 200 FEET 1 3 500 FEET 250 FEET 2 400 FEET 6 350 FEET 4 MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. PHOTO SURVEY STUDY with NUMBERS for REFERENCE 5 entrance LOOKING NORTH ON EAST VALLEY ROAD LOOKING EAST ON SW 41ST STREET LOOKING NORTH ON 167 LOOKING SOUTH ON 167 LOOKING SOUTH ON EAST VALLEY ROAD LOOKING WEST ON SW 41ST STREET 4 5 6 MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. DOUBLE FACED PYLON SIGNS 6 FABRICATED ALUMINUM CABINET W/ CARMAX SATIN BLUE FINISH. ACRYLIC FACE ALUMINUM CHANNEL LETTERS/DASHES. CAR/DASHES HAVING YELLOW FACES/YELLOW RETURNS & TRIM CAP MAX HAVING WHITE FACES/WHITE RETURNS & TRIM CAP INTERNAL WHITE LED LIGHTING IN LETTERS/DASHES. GRAPHICS AND COPY: “CAR & DASHES” - YELLOW #2037 “MAX- #2447 WHITE LETTER RETURNS - SATIN FINISH WHITE LETTER RETURNS - YELLOW PMS-109 SATIN FINISH CABINET CARMAX PMS-281 SATIN BLUE FINISH SQ. TUBE STEEL SUPPORT TO BE PER FH ENGINEERING REQUIREMENTS w/ MATTHEWS BRUSHED ALUMINUM FINISH ON ALUMINUM POLE COVERS. 277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS. DEDICATED CIRCUITS ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS Number of 277v - 20 Amp Circuits Req’d TBD DOUBLE-FACED PYLON SIGN ELEVATION END VIEW SCALE: 3/16” = 1’-0” PAINTED FINISH A1SIGN TYPE STANDARD INSTALL IS TO BE DIRECT PIPE EMBEDMENT INTO CONCRETE FOOTING PER FH ENGINEERING SPECS. MASONRY BASE TO MATCH BLDG MATERIALS BY GC (ALL CABINETS TO HAVE COUNTER-SUNK SCREWS AND FACES TO HAVE BUTT SEAMS) (ALL PYLON COVERS TO HAVE BUTT SEAMS)40'-0"23'-3" 1'-4 1/2" 26’-0”6'-3"2’-11”8"5"5"3’-2” 2'-4" FLAGGING REQUIRED TO DETERMINE APPROPRIATE HEIGHT 3’-0”145.31 SQ.FT 145.31 SQ.FT MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. DOUBLE FACED MONUMENT/ENTRY SIGN 7 SIDE A FABRICATED ALUMINUM CABINET W/ CARMAX BLUE FINISH. ACRYLIC FACE ALUMINUM CHANNEL LETTERS/DASHES. HAVING YELLOW FACES/YELLOW RETURNS & TRIM CAPCAR/DASHES HAVING WHITE FACES/WHITE RETURNS & TRIM CAPMAX INTERNAL WHITE LED LIGHTING IN LETTERS/DASHES. GRAPHICS AND COPY: “CAR & DASHES” - YELLOW #2037 “MAX- #2447 WHITE LETTER RETURNS - SATIN FINISH WHITE LETTER RETURNS - YELLOW PMS-10 SATIN FINISH 9 CABINET - CARMAX BLUE PMS-281 FINISH SATIN ENTRANCE CABINET - CARMAX WHITE FINISH PAINTED FINISH WHITE ALUMINUM CABINET W/ ROUTED COPY BACKED WITH #4774 WHITE ACRYLIC HAVING BLUE PERF. VINYL APPLIED TO FIRST SURFACE. INTERNAL H.O. FLUORESCENT LIGHTING. MASONRY BASE TO MATCH BLDG MATERIALS BY GC DOUBLE FACE LIGHTED MONUMENT SIGN ELEVATION (1) REQ’D END VIEW SIDE B RECT. SUPPORT COVER WITH MATTHEWS BRUSHED ALUMINUM FINISH 34.4 SQ. FT. 277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS. DEDICATED CIRCUITS ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS Number of v - 20 Amp Circuits Req’d TBD 277 STANDARD INSTALL IS TO BE DIRECT PIPE EMBEDMENT INTO CONCRETE FOOTING PER FH ENGINEERING SPECS. SCALE: ½”= 1’-0” A2SIGN TYPE (ALL CABINETS TO HAVE COUNTER-SUNK SCREWS AND FACES TO HAVE BUTT SEAMS) (IF ALUM. COVER REQ'D, BUTT SEAMS TO BE USED)5'-0"entrance entrance 9'-3"1’-0”3 1/4"3’-8 3/4”9 1/2"5 1/2"9’-9 1/2”1’-2”3”1’-10” 1’-4” 5"5" MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. INDIVIDUAL ILLUMINATED CHANNEL LETTERS (TWO REQ’D)CM-CL55 INDIVIDUAL LED ILLUMINATED CHANNEL LETTERS (ONE SET REQ’D) 26.7 SQ. FT. 26.7 SQ. FT. 55.0 SQ. FT. CM-S-CL26 NEXT GEN 2 EXTERIOR WALL SIGNS scale 3/8"=1'-0" scale 1/2"=1'-0" GRAPHICS AND COPY: “CAR & DASHES” - YELLOW #2037 ACRYLIC FACES- CARMAX SATIN PMS-109 YELLOW RETURNS - YELLOW TRIM CAP “MAX” - WHITE #2447 ACRYLIC FACES - SATIN WHITE RETURNS - WHITE TRIM CAP BLUE ACM BACKGROUND BY CARMAX G.C. 277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS. DEDICATED CIRCUITS ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS Number of 277v - 20 Amp Circuits Req’d TBD 8 BSIGN TYPE CSIGN TYPE Custom Wireway Behind Wall No Penetrations within 4” of Seam Hinge required to allow back to swing open WIREWAY BEHIND WALL ¼" Ø Stainless Steel 5 7/8" 55 SQ. FT BLUE ACM WALL PANELS BY GC 4"4"NO PENETRATIONS IN THIS AREA WIREWAY BEHIND WALL 16'-8" WALL PANEL 16'-6 1/2"2'-6"3'-3 1/2"2'-2 1/2"1'-8"10'-4 "2’-7 1/8”GRIP-GARD SATIN FINISH CARMAX BLUE (PMS-281) RETURNS LETTER COLORS PMS-281 BLUE DAY/NIGHT PERF. VINYL FACE OVERLAY CLEAR ACRYLIC FACES/SECOND SURFACE WHITE DIFFUSER W/ BLUE TRIM CAP w/ Vinyl Overlay MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. ELEVATIONBSIGN TYPE CONCEALED WIREWAY SPECIFICATIONS: Ÿ 4” deep (additional blocking by GC will be shown on architectural detail for supporting wire way) Ÿ Wiring for the letters may be drilled straight through the sign band into the wire way. Ÿ Power supplies to be mounted inside the same wire way. Ÿ The wire way will have a door on the back that opens (swings up) to expose all of the wiring and power supplies allowing for easy installation and service. Ÿ The wire way will be painted blue to match (the adjacent ACM) ‘Dash’ Section on Wireway 8" ‘C’ Section On Wireway PLACEMENT OF SIGNS ON SIGN BAND 3'-6 7/8"4'-6 7/8"9 14’-2” RACEWAY 3’-4”OF JOINT 7 1/4” ACM SIGN BAND J-Box Inside Wireway TOP OF SIGN BAND BOTTOM OF SIGN BAND MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. S/F ILLUMINATED CHANNEL LETTER WALL SIGN SCALE: 3/8” = 1’-0” 150 SQ. FT. 6"5" 277V ELECTRICAL REQ’D TYPICAL SECTION 277V-20 AMP CIRCUIT ELECTRICAL PRIMARY TO SIGN LOCATION AND THE FINAL HOOK-UP TO BE BY CUSTOMER’S CERTIFIED ELECTRICIAN. NUMBER OF CIRCUITS REQUIRED PER SIGN TO BE PER FEDERAL HEATH SIGN ENGINEERING SPECIFICATIONS AND REQUIREMENTS. DEDICATED CIRCUITS ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS(INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS Number of 277v - 20 Amp Circuits Req’d TBD CM-WS-CL 150 FABRICATED ALUMINUM CABINET WITH .125” ALUMINUM FACE - FILLER PAINTED CARMAX BLUE FACE PAINTED CARMAX BLUE (ALL CABINETS TO HAVE BUTT SEAMS & COUNTER-SUNK SCREWS) INDIVIDUAL ALUMINUM CHANNEL LETTERS WITH ACRYLIC FACES, TRIM CAP RETAINERS AND SLOAN WHITE LED LIGHTING. ATTACH LETTER CHANNELS TO BACKGROUND WITH #10 TEK SCREWS. WEEP HOLES REQ’D IN BOTTOM OF LETTERS 120V-277V/12VDC SLOAN LED POWER SUPPLIES TO BE HOUSED IN BACKGROUND CABINET. CUT OFF SWITCH TO BE LOCATED END OF CABINET. GRAPHICS AND COPY: “CAR & DASHES” - YELLOW #2037 ACRYLIC FACES- CARMAX SATIN PMS-109 YELLOW RETURNS - YELLOW TRIM CAP “MAX” - WHITE #2447 ACRYLIC FACES - SATIN WHITE RETURNS - WHITE TRIM CAP PMS-291 SATIN BLUE BACKGROUND 23'-3"6'-3"2’-11”8"DSIGN TYPE 10 MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. 11NEXT GEN 2 EXTERIOR ELEVATIONS 16'-8" 16'-6 1/2" 16'-8" 16'-6 1/2" 23'-3"D C26.7 SQ. FT. SIGN 55 SQ. FT. SIGN 55 SQ. FT. SIGN B B 150 S.F. SIGN 80’-5 1/2” 280'-6" tupelo MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. LOT DIRECTIONALS (non-illuminated) REFLECTIVE WHITE VINYL ARROWS 3M-680-10 FIRST SURFACE APPLIED. REFLECTIVE YELLOW VINYL COPY 3M-680-71 FIRST SURFACE APPLIED (COPY ON TWO FACES) ALUMINUM CABINET W/ CARMAX SATIN BLUE FIN. PAINTED BRUSHED ALUMINUM FINISH ON RECTANGULAR SUPPORT FRAME 2” 1 1/2”1 1/2” OPEN END VIEW 10”2 1/4"2 3/8"carrow SIDE A SIDE B 4'-0 "1'-4 3/4 "2'-10" 3'-2" LOT DIRECTIONAL scale 3/4"=1'-0" E1SIGN TYPE FOUR SQ. FT.(2) 1'-6"ø x 2'-6" DEEP CONC. FOOTING NOTE: ALUMINUM EMBEDDED IN CONC. MUST BE HAVE MOISTURE BARRIER COATING TO PREVENT CORROSION (2" X 10" X .125" RECT. TUBE) REFLECTIVE VINYL #3M-680-71 YELLOW REFLECTIVE VINYL #3M-680-10 WHITE CARMAX PMS-281 BLUE SATIN FIN. MATTHEWS BRUSHED ALUMINUM FIN. OPEN LOT DIRECTIONAL scale 3/4"=1'-0" E4SIGN TYPE SIDE A SIDE B 12 OPEN LOT DIRECTIONAL scale 3/4"=1'-0" E2SIGN TYPE SIDE A SIDE B BLANK MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. LOT DIRECTIONALS (non-illuminated) REFLECTIVE WHITE VINYL ARROWS 3M-680-10 FIRST SURFACE APPLIED. REFLECTIVE YELLOW VINYL COPY 3M-680-71 FIRST SURFACE APPLIED (COPY ON TWO FACES) ALUMINUM CABINET W/ CARMAX SATIN BLUE FIN. PAINTED BRUSHED ALUMINUM FINISH ON RECTANGULAR SUPPORT FRAME 2” 1 1/2”1 1/2” OPEN OPEN OPEN LOT DIRECTIONAL LOT DIRECTIONAL scale 3/4"=1'-0" END VIEW E8SIGN TYPE E9SIGN TYPE 10”2 1/4"2 3/8"carrow SIDE A SIDE A SIDE A SIDE B SIDE B 4'-0 "1'-4 3/4 "2'-10" 3'-2" LOT DIRECTIONAL scale 3/4"=1'-0" E6SIGN TYPE FOUR SQ. FT.(2) 1'-6"ø x 2'-6" DEEP CONC. FOOTING NOTE: ALUMINUM EMBEDDED IN CONC. MUST BE HAVE MOISTURE BARRIER COATING TO PREVENT CORROSION (2" X 10" X .125" RECT. TUBE) REFLECTIVE VINYL #3M-680-71 YELLOW REFLECTIVE VINYL #3M-680-10 WHITE CARMAX PMS-281 BLUE SATIN FIN. MATTHEWS BRUSHED ALUMINUM FIN. entrance entrance 13 SIDE B MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. 2" DOUBLE FACE ROW MARKER SIGN PANELSCM-D-RM scale 3/4"=1'-0" 14 G 2'-6 "2'-6"6'-0".FLAT 125” ALUMINUM PANEL WITH PAINTED PMS-032 RED FINISH ON ALL SURFACES. REFLECTIVE WHITE 3M-680-10 VINYL ON COPY AND BORDER (ONE SIDE ONLY)½”8” X 8” X ¼” ALUMINUM PLATE MOUNTED INTO CONCRETE WITH MASONRY ANCHORS. PAINT MATTHEWS 13B-2T GRAY SINGLE FACE SIGN ELEVATION | TWO (2)CM-D-SCD scale 1/2"=1'-0" J 2” X 2” X 3/16" SQUARE TUBE (6061-T6) PAINTED MATTHEWS 13B-2T GRAY OPERATIONAL SIGNS (non-illuminated) SINGLE FACE SIGN ELEVATIONCM-D-ESCORTH REFLECTIVE VINYL #3M-680-71 YELLOW REFLECTIVE VINYL #3M-680-10 WHITE CARMAX PMS-281 BLUE SATIN FIN. REFLECTIVE VINYL #3M 680-72 RED MATTHEWS FIN.13B-2T GRAY 2 3/4"2'-6 "2'-6 "10"STANDARD HIGHWAY SIGN PANEL (SETON 29594) .125” ALUMINUM SIGN PANEL PAINTED CARMAX BLUE ON ALL SURFACES. WHITE 3M 680-10 & 3M 680-17 YELLOW REFLECTIVE VINYL COPY SINGLE FACE “DO NOT ENTER” SIGN | TWO (2) 2” X 2” X 3/16" SQUARE TUBE (6061-T6) PAINTED MATTHEWS 13B-2T 2'-0 " CM-D-DNE scale 1/2"=1'-0" F6'-0"2’-0” FLAT .125” ALUMINUM PANEL PAINTED CARMAX BLUE 3M 680-10 WHITE REFLECTIVE COPY & 3M 380-71 YELLOW HIGHLIGHTED COPY.10"1 1/4"¾"1 3/4"PLATE MOUNTED TO CONCRETE SURFACE GRAY EXISTING LIGHT POLE .125” ALUMINUM PANEL WITH 1 ½” LEG FOR ATTACHMENT TO SUPPORT . PANEL PAINTED CARMAX BLUE BACKGROUND. COPY TO BE WHITE REFLECTIVE VINYL 3M-680-10. MOUNT TO PIPE WITH STAINLESS STEEL STRAP 1'-0 "1'-0 "10 "ROW MARKER 1'-0" 1 1/2" SPECIFICATIONS:FABRICATED .125" ALUMINUM PANELWITH 1 1/2" LEG FOR ATTACHMENT TOSUPPORT. PANEL TOBE PAINTED CARMAX BLUE.FIRST SURFACE COPY REFLECTIVEWHITE VINYL 3M 680-10.MOUNT TO 2" ALUMINUM SQ. TUBEPOSTS WITH 3/16" POP RIVET OR MOUNT TO LIGHT POLE WITHMETAL STRAP. EACH PANEL TO HAVETWO HOLES FOR POP RIVET MOUNTAND TWO 1” SLOTS FORSTRAP MOUNTING8’-0” ABOVE GRADE(SEE ROW MARKER DETAIL PAGE FOR EXACT MARKERS REQUIRED) A 3 SQ. FT.3 SQ. FT. 18 "18 "24 "CM-D-CW CM-D-CWE ALL SIGNS ARE TO BE MOUNTED FLUSH TO WALL AT ENTRANCE/EXIT LANES ON CAR WASH BUILDING - 4’-0” ABOVE GRADE FLAT .125” ALUMINUM PANEL W/ CARMAX BLUE BACKGROUND “STOP SIGN/DO NOT ENTER”- RED 3M-680-72 W/ COPY TO BE WHITE 3M-680-10 WALL PANEL WALL PANEL scale 1"=1'-0"scale 1"=1'-0"I1 I29 3/4"12"1"2"MAIN COPY TO BE 3M 680-10 WHITE MATT SMITH JESSICA VIDAL J. CARPENTER 15 LOCATION #7252 3751 EAST VALLEY ROAD RENTON, WA 98057 23-23170-10-R5 23-23170-10 FEBRUARY 24, 2014 R1-05-12-14 VA/JK Revise as per pdf mark up attached. R2-06-18-14 BW Revise graphics on sign I. R3 07.15.14 RM/JDR Update pages 2, 3, 13 and 14. Del page R4 03.4.15 VA/JDR Update Site plan to SP 13 R5 03.24.15 VA/JDR Update sign placement of Sign E6 & E8, Update arrow of Sign E4. NEXT GEN RESERVED (non-illuminated) LSIGN TYPEKSIGN TYPE .125” ALUMINUM PANEL WITH SCREENED LT. BLUE/DK. BLUE GRADATION ON FACE-SOLID BLUE ON BACKSIDE & EDGES. WHITE REFLECTIVE COPY .125” ALUMINUM PANEL WITH SCREENED YELLOW/ORANGE GRADATION ON FACE W/ ORANGE BACKSIDE & EDGES 3M 680-75 BLUE REFLECTIVE COPY 1'-2"1'-2"5’-0”5’-0”S/F SIGN PANEL WITH MOVEABLE BASE (LEED CERTIFIED) / FIVE (5) REQ’D S/F SIGN PANEL WITH MOVEABLE BASE (LEED CERTIFIED) / THREE (3) REQ’D SCALE: 3/4” = 1’-0”SCALE:3/4” = 1’-0”1'-8 "1'-8 "ROUNDED CORNERS (1" RADIUS)ROUNDED CORNERS (1" RADIUS) 15