Loading...
HomeMy WebLinkAbout08-SCL Creston-Talbot_Site Plan Package 11x17!A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A!A SCL Creston-Talbot Fiber ProjectProject Extents Legend !A Existing 230kV SCL transmission structure Proposed Overhead ADSS fiber aligmentJurisdiction Unincorporated King County Renton Seattle Tukwila Contact: Dirk FraileyHDR Engineering, Inc.1001 SW 5th Ave., Suite 1800Portland, OR 97204(503)-423-3887 Ü TalbotSubstation CrestonSubstation !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A !A I-405 FWY SW 7th St Cedar River Trail S 3rd St Ra i n i e r Av e SN 3rd St Beacon Way S S W G r a d y W a y SW Sunset BlvdWells Ave SS G r a d y W a yHardie Ave SWGrant Ave SS 4th St S 134th St Renton Ave S Williams Ave SBenson Rd SS 7th St Talbot Rd SS 132nd St Shattuck Ave SS 5th St Main Ave SS 1 4 t h S tLind Ave SWS 15th St SW 3rd Pl N 1st St S Tobin St S W 1 2 t h S t N E 3 rd S tSW Langston Rd S 130th St Burnett Ave SMaple Valley Hwy Cedar Ave SAirport Way Park Ave NHigh Ave SS W 1 0 th S tLogan Ave SPark Aly NH ouser W ay S Mill Ave SS/B I-4 0 5 R a m p S 3rd Aly S Langston Rd N/B I-405 RampPelly Ave NS 2nd St Pelly Aly NSW 5th PlS Tillicum St Access RdLake Ave SStevens Ave SWPrivate Rd S 9th St SW 4th Pl S 135th St N 2nd St Garden Ave NWells Ave NSE 8th PlSunset Blvd NWells Aly NMeadow Aly NGarden Aly NFactory Ave NS 3rd Pl Meadow Ave NJones Ave STaylor Ave NWCedar Aly SB ro n s on Wa y N Blaine Ave NEW Perimeter RdGrant Aly SThomas Ave SWMaple Ave SW80th Ave SSmithers Aly SN Riverside Dr S W 1 3 th S t S 133rd Pl Powell Ave SWSR 167 Ramp Williams Ave NHardie Ave NWFactory Aly NSE 8 th Dr SW Victoria St G r a d y A l y S W SR 167Ac c es s Rd wy 84th Ave SHouser Way NLind Ave NWRai ni er Ave NLogan Ave NNaches Ave SWBurnett Aly SBronson Way NEMonterey Dr NEEarlington Ave SWS 4 t h P lNW 2nd St High Aly SSE 2nd Pl S Renton Village PlSeneca Ave NWWilliams Aly NMaple Ave NWRenton HS AcRdE P erim eter R d SE 8th St Pedestrian Walk Capri Ave NESE 7th CtBronson Way SSW 2nd St Wells Aly SN Marion St Burnett Ave NNW 3rd St NW 3rd Pl Morris Ave SMorris Aly SRenton Ave ExtSW 5th Ct S W 1 2 t h A l y Rivie r a Ap a rt me n t s A c RdOakesdale Ave SWStevens Ave NWBlaine Dr SE Seneca Ave SWDavis Ave SEagl e Ri dge Dr SSmithers Ave SHayes Pl S W Williams Aly SMain Aly SN 3rd Aly Mill Aly SS 6th St SW Langston Pl S 5th Pl78th Ave SS 134th Pl R ento n C enter Way S WWhitworth Ave SSam's Club AcRdSW 2nd Pl Whitworth Aly SWoodcliffe Apartments AcRdS 6th Aly N Marion Aly Renton Village AcRd88th Ave SRaymond Ave SW89th Ave SI-405 FWYAccess RdOakesdal e Ave SWAccess RdAc c ess RdLind Ave SWThomas Ave SWSW 4th P l Private RdP riv a te R d Access Rd S 6th St Access RdS/B I-405 Ramp Main Aly SN/B I-405 RampSE 8th Pl S W 1 3 t h S t S Tobin St Private RdS 7th St P riva te Rd H ouser W ay S Renton Ave SPowell Ave SWS 4th St Access Rd 84th Ave SS/B I-405 Ramp S 134th St Whitworth Ave SMorris Ave S80th Ave SWhitworth Aly SSmithers Aly SWells Aly SSmithers Ave SBurnett Aly SOakesdale Ave SWAccess Rd Ac c e s s Rd Ac c e s s Rd Private RdAccess RdS/B I-405 RampS 3rd StLake Ave S Mill Ave SS/B I-405 RampAccess RdSW 4th Pl Access RdA c c e s s R d SCL Creston-Talbot Fiber Projectwithin Renton City Limits Legend !A Existing 230kV SCL transmission structure Proposed Overhead ADSS fiber aligment Contact: Dirk FraileyHDR Engineering, Inc.1001 SW 5th Ave., Suite 1800Portland, OR 97204(503)-423-3887 Renton Renton Unincorporated King County Unincorporated King County Ü Structure 118 TalbotSubstation PLS-CADD DRAWING -5+00 0+00 5+00 10+00 15+00 20+00 25+00 30+00 35+00 40+00 45+00 50+00 240260280300320340360380400420440460480500520540560580600240 80260 100280 120300 140320 160340 180360 200380 220400 240420 260440 280460 300480 320500 340520 360540 380560 400580 420600 44080 0100 20120 40140 60160 80180 100200 120220 140240 160260 180280 200300 220320 240340 260360 280380 300400 320420 340440 360020406080100120140160180200220240260280300320340360 PI 0°00'00" PI 42°46'50" PI -65°05'11" PI -7°27'59" PI 0°01'10" PI 16°18'06" TA STA=0+00 TS0_3 STA=3+36 TS0_5 STA=5+98 B27_29S STA=10+21 13A1 LATTICE TOWER B27_36S STA=16+71 13A2 LATTICE TOWER B27_43S STA=23+41 13D1 LATTICE TOWER 336 262 423 650 670 PI -0°02'02" PI 0°08'17" B28_02S STA=35+21 13A2 LATTICE TOWER B28_06S STA=39+70 13A2 LATTICE TOWER 1180 450 PI 31°13'59" B28_14S STA=47+59 13D2 LATTICE TOWER 789 TA TS0_3 TS0_5 B27_29S B27_36S B27_43S B28_02S B28_06S B28_14S 129 B27/22S B27/19S 1 A B C 2 3 4 5 6 7 8 D 0 1" 2" PROJECT MANAGER PROJECT NUMBER DESCRIPTION DATE ISSUE PROJECT ENGINEER DESIGN ENGINEER CADD TECHNICIAN WORK ORDER SCALE PLAN & PROFILE RENTON, WA CRESTON - TALBOT FIBER ADDITION 230 KV TRANSMISSION LINE D. FRAILEY T. MORGAN D. WIEST A 5/22/2015 30% PRELIMINARY FIBER OPTIC DESIGN PRELIMINARY NOT FOR CONSTRUCTION SHEET H: 1" = 200` V: 1" = 40` 1 OF 3 APPROXIMATE LOCATION OF PSE/BPA FIBER VAULT BEGIN FIBER UNDERBUILD ON TRANSMISSION TRANSMISSION CROSSING TRANSMISSION CROSSING TRANSMISSION CROSSING TRANSMISSION CROSSING DISTRIBUTION CROSSING ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 677FT SECTION CONTINUES TO STR. B27/22S ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 954FT ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 769FT I-405 BENSON DR S BEACON WAY S PROPOSED ADSS FIBER OPTIC CABLE PROPOSED ADSS FIBER OPTIC CABLE Talbot Substation PLS-CADD DRAWING 50+00 55+00 60+00 65+00 70+00 75+00 80+00 85+00 90+00 95+00 100+00 020406080100120140160180200220240260280300320340360020406080100120140160180200220240260280300320340360 PI 9°20'37" PI 51°33'57" PI -0°01'17" PI -30°02'43" PI -0°03'01" PI 0°02'15" PI 0°00'08" 129 STA=55+59 B2-D STEEL MONOPOLE 128 STA=62+97 D-2D STEEL MONOPOLE 127 STA=70+13 B-2D STEEL MONOPOLE 126 STA=78+79 D-2D STEEL MONOPOLE 125 STA=86+26 B-2D STEEL MONOPOLE 124 STA=92+14 B-2D STEEL MONOPOLE 123 STA=98+71 D-2 STEEL MONOPOLE 799 738 717 866 747 588 657 659 B28_14S 129 128 127 126 125 124 123 122 121 1 A B C 2 3 4 5 6 7 8 D 0 1" 2" PROJECT MANAGER PROJECT NUMBER DESCRIPTION DATE ISSUE PROJECT ENGINEER DESIGN ENGINEER CADD TECHNICIAN WORK ORDER SCALE PLAN & PROFILE RENTON, WA CRESTON - TALBOT FIBER ADDITION 230 KV TRANSMISSION LINE D. FRAILEY T. MORGAN D. WIEST A 5/22/2015 30% PRELIMINARY FIBER OPTIC DESIGN PRELIMINARY NOT FOR CONSTRUCTION SHEET H: 1" = 200` V: 1" = 40` 2 OF 3 I-405 CROSSING TRANSMISSION CROSSING TRANSMISSION CROSSING TRANSMISSION CROSSING ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 769FT ADSS: 144CT DNA-31512 MWT = 3300# @ NESC MEDIUM INITIAL; RS = 799FT ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 588FT RAILROAD CROSSING ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 673FT SW SUNSET BLVD RAILROAD CROSSING HIGHWAY 167 S 7TH ST S GRADY WAY I-405 PROPOSED ADSS FIBER OPTIC CABLE PLS-CADD DRAWING 105+00 110+00 115+00 120+00 125+00 130+00 135+00 140+00 145+00 150+00 155+00 0204060801001201401601802002202402602803003203403600 10020 12040 14060 16080 180100 200120 220140 240160 260180 280200 300220 320240 340260 360280 380300 400320 420340 440360 460100 260120 280140 300160 320180 340200 360220 380240 400260 420280 440300 460320 480340 500360 520380 540400 560420 580440 600460 620260280300320340360380400420440460480500520540560580600620 PI 0°01'45" 122 STA=105+30 A-2 STEEL MONOPOLE 659 424 PI -5°29'51" PI -6°52'22" 121 STA=109+54 A-2 STEEL MONOPOLE 120 STA=115+72 A-2 STEEL MONOPOLE 618 798 PI -0°04'32" PI -2°21'05" PI -7°32'44" PI -0°00'59" PI 0°06'53" 119 STA=123+70 A-2 STEEL MONOPOLE 118 STA=132+71 A-2 STEEL MONOPOLE 117 STA=140+06 A-2 STEEL MONOPOLE 116 STA=148+42 A-2 STEEL MONOPOLE 115 STA=155+07 A-2 STEEL MONOPOLE 901 735 836 665 122 121 120 119 118 117 116 115 114 1 A B C 2 3 4 5 6 7 8 D 0 1" 2" PROJECT MANAGER PROJECT NUMBER DESCRIPTION DATE ISSUE PROJECT ENGINEER DESIGN ENGINEER CADD TECHNICIAN WORK ORDER SCALE PLAN & PROFILE RENTON, WA CRESTON - TALBOT FIBER ADDITION 230 KV TRANSMISSION LINE D. FRAILEY T. MORGAN D. WIEST A 5/22/2015 30% PRELIMINARY FIBER OPTIC DESIGN PRELIMINARY NOT FOR CONSTRUCTION SHEET H: 1" = 200` V: 1" = 40` 3 OF 3 DISTRIBUTION CROSSING DISTRIBUTION CROSSING DISTRIBUTION CROSSING ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 588FT ADSS: 144CT DNA-31512 MWT = 3200# @ NESC MEDIUM INITIAL; RS = 773FT 78TH AVE S RENTON AVE S PROPOSED ADSS FIBER OPTIC CABLE PROPOSED ADSS FIBER OPTIC CABLE WITHIN RENTON CITY LIMITSUNINCORPORATED KING COUNTYWITHIN RENTON CITY LIMITSUNINCORPORATED KING COUNTY