Loading...
HomeMy WebLinkAbout01 - Pre-App Mtg SummaryGeneral:We have completed a preliminary review of the pre-application for the above-referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review on September 25, 2014. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision-makers (e.ge, Hearing Examiner, Community & Economic Development Administrator, Public Works Administrator, Planning Director, Development Services Director, and City Council). Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. the applicant is encouraged to review all applicable sections of the Renton Municipal Code. The development Regulations are available for purchase for $100.00 plus tax, from the Finance Division on the first floor of City Hall or online at www.rentonwa.gov. M E M O R A N D U M DATE: TO: FROM: SUBJECT:(Highlands Reservoir Replacement) PRE14-001202 Pre-Application File No. PRE14-001202 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT 9/25/2014 12:00:00AM Kris Sorensen, Associate Planner Project Proposal: The subject property is located at 3410 NE 12th St, east of the intersection at NE Sunset Blvd and NE 12th St (PID 0423059186). The almost 5-acre site currently has large and small water utility-related facilities and private and public communication facilities. For the City’s water system, the City recently completed an alternatives analysis for master planning for the site to replace aging infrastructure and meet future needs. The submitted materials for the preferred alternative show an initial first phase with improvements and an additional overall master plan for the site. The first phase includes construction of a partially buried 6.3 million gallon reservoir in the undeveloped easterly portion of the site, an access road around the site, and new energy generator under a new 4-pole shelter to replace the existing generator. Future phases anticipated include the demolition of the two existing partially buried reservoirs, construction of a 4.1 million gallon partially buried reservoir in the location of the existing reservoirs, demolition of the existing small buildings that house the booster pump and chlorination facilities, and demolition and replacement of the elevated tower reservoir. Vehicle access to the site is gained from NE 12th St at two points. The site is located in the Aquifer Protection Zone. Critical areas identified on-site are steep slopes surrounding the existing partially buried reservoirs. Current Use: The project site has a number of large and small existing improvements including an elevated water tower, two partially buried water storage reservoirs, booster pump station, a few small structures, power generator, antennas for wireless companies, and a radio tower. Zoning: The property is located within the Residential Medium Density (RMD) land use designation and the Residential-10 du/ac (R-10) zoning classification. The project would be subject to RMC 4-2-110A, “Development Standards for Residential Zoning Designations” effective at the time of complete application (noted as “R-10 standards” herein). Large utilities are allowed within the R-10 zoning classification designation with an approved Hearing Examiner Conditional Use Permit (CUP). The proposal would be considered a major revision to the existing facility and would therefore require a new application for a CUP. Page 1 of 4 Density – Density is not applicable as there residential uses are not part of the proposal. Minimum Lot Size, Width and Depth – There are no minimum lot size, width or depth requirements. Building Standards – Height: The R-10 zone restricts building height to 30 feet with an exception for public water system facilities which are allowed the following height bonus (per RMC 4-2-110D, Note 9): a. Water towers/reservoirs are permitted up to a maximum height of one hundred seventy five feet (175') to the highest point of the reservoir. The overall proposal would be construction of two partially buried reservoirs and an elevated tank or standpipe that would be less than 175 feet at the highest point of the proposed water facilities and comply with the height allowance. The two reservoirs would be approximately 9 and 22 feet at the highest points from existing grade and the water tower or standpipe would be approximately 129 feet in height. b. Water treatment facilities and pump stations are allowed up to fifty feet (50') subject to site plan development review. The setback standards may be modified to increase setbacks as part of the site plan development review approval. The future structure that would house the booster pump station and water quality/chlorination facilities, constructed as part of Phase 2, would need to comply with the maximum 50-foot height limit. c. Public utility facilities exceeding fifty feet (50') in height shall be treated with public art consistent with RMC 4-9-160. Such public art shall be eligible for one percent (1%) for art funding and shall be reviewed by the Renton Municipal Arts Commission. The only facility proposed above 50 feet in height is the future elevated tank or standpipe in the northern portion of the site that would occur in Phase 2 or later. This facility would require public art. d. The “d” subsection has criteria for additional height beyond 175 feet which is not needed given the proposed tower and reservoirs are each less than 175 feet in height. Height for Communication Facilities: The site has existing private communication antennas and a public radio tower. The proposal is to relocate these facilities on site and the relocation areas and heights and dimensions would be required to be shown as part of the application to be reviewed as part of site plan review. Building surface coverage: There is no maximum coverage. Impervious surface coverage: The maximum coverages are established for residential uses at 75% for detached units and 65% for attached units. Impervious surface coverage would be reviewed as part of Site Plan review. Coverage analysis and dimensions of impervious areas would be required at time of application to for the different phases of site development. Building Design Standards – Not applicable to this proposal as there are no residential uses. Setbacks – Setbacks are the minimum required distance between the building footprint and the property line. The required setbacks in the R-10 zone are 10 feet for the primary structure in the front yard, 12 feet in the rear, and 4 feet for an interior side yard setback. The proposal appears to comply with the setback requirements of the zone. Setbacks for existing and proposed structures would need to be shown as part of the site plan review application. Landscaping – Except for critical areas, all portions of the development area not covered by structures, required parking, access, circulation or service areas, must be landscaped with native, drought-resistant vegetative cover. The development standards require that all pervious areas within the property boundaries be landscaped. •Landscaping near the street: Ten feet (10') of on-site landscaping is required along all public street frontages, with the exception of areas for required walkways and driveways and those zones with building setbacks less than ten feet (10'). The applicant would be required to provide a 10-foot on-site landscape strip along the NE 12th St frontage unless reduced through the site plan development review process. Additionally, there are requirements for plantings within the right-of-way if a planting strip is required, where street trees and ground cover would be located. •When a Nonresidential Development is located in a Residential Zone a visual buffer is required at the shared property lines. Either a 15 feet wide partially sight-obscuring landscaped visual barrier or 10 feet wide fully sight-obscuring landscaped visual barrier is required along the common property line. The 10 or 15-foot Page 2 of 4 visual barrier is required on along all sides of the proposal with the exception of the street frontage side as there are single and multi-family residences surrounding the subject site. The Site Plan submitted with application materials shows a landscape strip around the site that varies in width and may not comply with the requirement. •Storage area on-site: The Master Plan sheet submitted as part of the application materials states that the area between new reservoirs may be paved or graveled to provide for maintenance and storage area and would have a landscaped buffer surrounding the area. Please refer to landscape regulations (RMC 4-4-070) for additional general and specific landscape requirements. Phasing of proposed on-site and right-of-way landscape improvements would be required as part of an application. Significant Tree Retention: If significant trees (greater than 6-inch caliper) are proposed to be removed a tree inventory and a tree retention plan along with a tree retention worksheet shall be provided with the formal land use application. The tree retention plan must show preservation of at least 10 percent of significant trees, and indicate how proposed structures and building footprints would be sited to accommodate preservation of significant trees that would be retained. If the trees cannot be retained, they may be replaced with minimum 2 inch caliper trees at a ratio of six to one. The applicant’s submittal includes a tree inventory and states that as part of the first phase, 50 to 65 trees would be proposed for removal, and additional trees would most likely be removed as part of future phases. A tree retention and replacement plan would be required as part of the land use application. Access – Driveway widths are limited by the driveway standards in RMC 4-4080I. Access to the site would be gained from NE 12th St in two locations according the submitted application. There are two existing access points from NE 12th and the master plan shows one access point where the more southerly access point currently exists with the northern access being removed through the phased development. A permanent 15-foot wide access road is proposed as part of Phase 1 that would circle around the proposed easterly reservoir that connects with the NE 12th access point. Driveways and access roads may not be greater than 15% slope. Fences: Location, maximum heights, and other fence standards can be found in RMC 4-4-040. New fence details and elevations would need to be provided as part of an application. Critical Areas: The City of Renton’s Critical Areas maps indicate the subject site has steep slopes and is located in the Aquifer Protection Zone 2. The overall purpose of the aquifer protection regulations is to protect aquifers used as potable water supply sources by the City from contamination by hazardous materials. Some uses are restricted that store, handle, treat, use, or produce substances that pose a hazard to groundwater quality. If fill is imported to the site, a fill source statement will be required. Additionally, steep slopes surround the existing partially buried reservoirs. The slopes identified are between 15 and 25 percent and between 25 and 40 percent and were likely created to support the existing reservoirs. Steep slopes are Geological Hazards therefore, a geotechnical study may be required. If steep slopes are proposed as part of the construction of new reservoirs or other improvements to the site, a geotechnical study would need to address the slopes. The study shall demonstrate that the proposal will not increase the threat of the geological hazard to adjacent properties beyond the pre-development conditions, the proposal will not adversely impact other critical areas, and the development can be safely accommodated on the site. In addition, the study shall assess soil conditions and detail construction measures to assure building stability. Environmental Review: The proposal would require SEPA review. Optional Land Use Reviews: The applicant may wish to consider a Master Site Plan Review application along with the additional required land use application (identified below). The development following the first phase could be processed through an Administrative Site Plan review rather than go through an additional Hearing Examiner Site Plan review process provided the expiration date for the Master Site Plan approval does not pass. A Master Plan is not required in a residential zone but is an option. The purpose of the master plan process is to evaluate projects at a broad level and provide guidance for development projects with multiple buildings on a single large site and allows for analysis of overall project concepts and phasing. Page 3 of 4 Permit Requirements: The proposal would require a Hearing Examiner Conditional Use Permit approval, Hearing Examiner Site Plan Review, and SEPA Environmental Review approval which would be reviewed within an estimated timeframe of 12 weeks. The Conditional Use application fee is $2,000, Site Plan application is $2,000, and Environmental Review application is $1,000. If the applicant choses to apply for a Master Site Plan the application fee would be $2,000. There is a technology fee, of 3%, based on the total land use application fees for the project. Detailed information regarding the land use application submittal is provided in the attached handouts. In addition to the required land use permits, separate construction and building permits would be required. Fire review would require separate permits for the energy generator. The review of these permits may occur concurrently with the review of the land use permits, but cannot be issued prior to the completion of any appeal periods. Impact Mitigation Fees: In addition to the applicable building and construction fees, fire and transportation impact fees may be required prior to the issuance of building permits. A handout listing all of the City’s Development related fees in attached for your review. Note: When the formal application materials are complete, the applicant is strongly encouraged to have one copy of the application materials pre-screened at the 6th floor front counter prior to submitting the complete application package. Please contact Kris Sorensen, Associate Planner at 425-430-6593 or by email at ksorensen@rentonwa.gov for an appointment. Expiration: Upon approval, conditional use and site plan approvals are valid for two years with a possible two-year extension if requested in writing prior to the expiration. A master site plan approval for a phased plan can be granted for up to ten years with a possible extension, and such approval shall include clearly defined phases and specific time limits for each phase and a determination of eligibility for any extensions of the time limits. Page 4 of 4 NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-binding and may not subject to modification and/or concurrence by official city decision-makers. Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. I have completed a preliminary review for the above-referenced proposal. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: TO: FROM: SUBJECT:(Highlands Reservoir Replacement) PRE14-001202 Vicki Grover, Plan Reviewer Kris Sorensen, Associate Planner 9/25/2014 12:00:00AM I have completed a preliminary review for the above-referenced proposal located at parcel 0423059186. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. WATER 1.The proposed development is within City of Renton Water District. SANITARY SEWER 1.Sewer service is provided by the City of Renton. The future phase will require a cut and cap of the existing side sewer connection for the chlorination building and vault. SURFACE WATER 1.A drainage report complying with the 2009 King County Surface Water Design Manual and City of Renton Amendments to the KCSWM, Chapters 1 and 2 shall be required. Based on the City’s flow control map, this site falls within the Flow Control Duration Standard, Forested Site Conditions (north and east sides of the site) and the Peak Rate Flow Control Standard, existing site conditions (south and west sides of the site). Refer to Figure 1.1.2.A – Flow Chart to determine the type of drainage review required by the City of Renton 2009 Surface Water Design Manual Amendment. The final drainage plan and drainage report must be submitted with the utility construction permit application. 2.A geotechnical report is required for the site. Information on the water table and soil permeability. The report shall include information to determine if the site is suitable for infiltration and a design infiltration rate. 3.A study shall be required to verify downstream capacity for the overflow from the reservoirs and an evaluation of downstream environmental impacts may be required. 4.Surface water system development fee (SDC) will be applicable. The current rate of SDC fee $0.491 per square foot of new impervious surface area, but not less than $1,228.00. 5.A Construction Stormwater General Permit from Department of Ecology will be required if grading and Page 1 of 2 clearing of the site exceeds one acre. A Stormwater Pollution Prevention Plan (SWPPP) is required for this site. TRANSPORTATION/STREET 1.Transportation impact fees will apply to this project. The actual rate will be assessed at a later date. This fee will be based on the amount of building area and its use per the ITE Manual. Payment of the transportation impact fee is due at the time of issuance of the building permit. 2.Road Classification – Minor Arterial/North 12th Street •Existing right of way width – approximately 60 ft. on North 12th Street with 2 travel lanes. •Required ROW width - Based on RMC 4-6-060, North 12th St. requires 91 ft. •ROW dedication needed – Approximately 15.50 feet on the north side of North 12th Street. •11 ft. travel lanes, a 5 ft. bike lane, 0.5 ft. curb and gutter, 8 ft. sidewalk and 8 ft. planter strips will be required. 3.The final ROW dedication will need to be verified by survey. All storm drainage improvements are required to be constructed per RMC 4-6-060. 4.Paving and trench restoration will comply with the City’s Trench Restoration and Overlay Requirements. General Comments 1.All construction or service utility permits for drainage and street improvements will require separate plan submittals. All utility plans shall conform to the Renton Drafting Standards. Plans shall be prepared by a licensed Civil Engineer. 2.When utility plans are complete, please submit three (3) copies of the drawings, two (2) copies of the drainage report, permit application, an itemized cost of construction estimate, and application fee at the counter on the sixth floor. Page 2 of 2 Fire & Emergency Services Department M E M O R A N D U M DATE: TO: FROM: SUBJECT:(Highlands Reservoir Replacement) PRE14-001202 Kris Sorensen, Associate Planner 9/17/2014 12:00:00AM Corey Thomas, Plan Review/Inspector 1. Separate plans and permits required for the relocation/replacement of the emergencey electrical generator if it has an associated fuel storage tank. Page 1 of 1 M E M O R A N D U M DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT DATE: TO: FROM: SUBJECT:(Highlands Reservoir Replacement) PRE14-001202 Kris Sorensen, Associate Planner Craig Burnell, Building Official Page 1 of 1